Explosion Proof & Hazardous Area Junction Boxes

Similar documents
Spec 5 Conduit Bodies, Covers and Gaskets For Rigid Conduit and IMC

Applications. Illustrated Features

Hazardous Duty Applications

Areamaster LED Flood/High Bay Luminaires

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations.

Form 85 Unilets Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit.

MagnaPro Hazardous Area Drop Lens Fluorescent

DuraPro Hazardous Area Fluorescent

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33

LB125A 1-1/4" LB Form 5 Aluminum Conduit Body. Dimensions and Weight STUD SIZE #10; 0.97 INCH LENGTH; INSULATION SUPPORT

Form 35 Malleable Iron Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

ALUMINUM OUTLET BODIES

LOW PROFILE LINEAR ALUMINUM LED EXCLUSIVE DESIGN FEATURES

MHD2/MHDO SERIES MHD2. Marine Heavy Duty Outdoor Non-Metallic Fluorescent CLASS 1 DIVISION 2 FLUORESCENT LIGHT

T38 1" T Form 7 Malleable Iron Conduit Body. Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

J-1. Explosion-Proof Junction Unilets. Features: Junction Boxes Outlet Boxes

LOW PROFILE LINEAR ALUMINUM LED EXCLUSIVE DESIGN FEATURES

SXPJ SERIES S X. HID & Compact Fluorescent Lighting for Hazardous and Hostile Locations

MHD2/MHDO SERIES M H D 2. Marine Heavy Duty Non-Metallic Fluorescent

MHDS SERIES M H D S. Stainless Steel Marine Heavy Duty Luminaire for Hazardous Locations

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

COMMERCIAL AND INDUSTRIAL FITTINGS: CONDUIT BODIES. Applications

Explosion Proof Receptacle - Integral Circuit Breaker - Class 2 Division 1-30 Amp 480VAC

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof

Code Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit.

Twist Lock - Explosion Proof - Dust Ignition Proof Receptacle Assembly

FM8 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

^ % P-SERIES Temperature Switches. Switches for -30 through 510 F with Adjustable Set Points and Fixed or Adjustable Deadband

D2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

XPF. XPFMax Performer/al FEATURES TECHNICAL SPECIFICATIONS

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

Seismic Sensor Accessories SA, SV & ST 6000 Series

Three Phase Explosion Proof Switch - Non Fused - 60 Amps - Early Break Auxiliary Contacts

TERMINAL BOXES FOR HARSH & HAZARDOUS ENVIRONMENTS

CONTROLS: NEC/CEC EXPLOSIONPROOF CONTROL STATIONS AND SWITCHES. Applications. Illustrated Features

SAFR LED SERIES S A F R L E D. Hazardous Location LED Luminaire

BUB400M 4-In Mog Cond Body. Features. Material, Color, and Finish. Dimensions and Weight

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

Aluminum Conduit Bodies, Covers and Gaskets For Rigid Conduit & IMC.

AFL FLOODLIGHT SERIES

EXBLI & EXBSPI Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

LIGHTING: EXPLOSIONPROOF FLOODLIGHT. Applications. Options

Condulet Cast Device Boxes and Covers Application and Selection

20EVP-A SERIES. Vertical In-Line Self-Priming Centrifugal Pumps for Petroleums and Solvents. Marlow Pumps. Marlow Pumps.

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

Rigid Metal Conduit, IMC or EMT K-Clamps

Spring-loaded cover seats against neoprene gasket.

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

Explosionproof enclosures XPCJ series Cast aluminum steel control/junction box

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

Sample Installation: Fixed Power Source (Wall) to Remote/Portable Location

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.

Applications. Separate sealing chamber and switch construction. Used on 20 Amp 4-way and all 30 Amp models.

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

Applications. Standard Materials

FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

ITT. Goulds Pumps. Marlow Series 20EVP. Engineered for life. Commercial Water

BOSS Lighting Hazardous Location Fluorescents Quartz Halogen Floodlights. BOSS Electrical Panels Panel Hardware. PLUS... BOSS Wiring Devices

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

Haz. HazMax Intrepid/nm TECHNICAL SPECIFICATIONS

HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF. Applications. Options

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY[R] IRON ALLOY (US), COPPER FREE ALUMINUM (CANADA)

Hazardous Factory Sealed Control Devices

Control Circuit and Industrial Interlock

Plugs and Receptacles: Hazardous Location

N2LED Series Emergency Luminaires Non-Metallic Emergency Egress Lighting Systems with Remote or Direct Mounted Lamps.

STAINLESS STEEL PANEL MOUNT

Condulet Single Gang Cast Device Boxes With and Without Mounting Lugs for Threaded Rigid and IMC Conduit

FM9 Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

24W Explosion Proof POE Injector - Adds Power Over Ethernet Functionality to 24V POE Equipment - 1A

4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D)

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.

Control Circuits Connectors Type SK & SKW Overview

ACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC)

Standard Finishes Receptacles: epoxy powder coat Cord connector housings and caps: epoxy powder coat

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC

003 3 foot foot RUN Nominal Length* * For actual lengths see

Jefferson Electric Class I Division 2 Transformers for hazardous locations

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

SXPJ SERIES S X azz.com/rigalite

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

MAR SERIES Fluorescent Lighting for Hazardous Locations

GHG43 Series Control Stations

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

ACP6034BC 60A 3W4P P&S Plug (600VAC/250VDC)

APPLICATIONS APPROVALS. GASKET One piece neoprene. LATCHES Plated steel twist draw. ENTRIES 1 2 NPT feed-through outlets, 3 4 NPT outlets optional.

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

Heating Cable. Construction

4 qwer. Main Pulse Valves Dust Collector 2/2 SERIES H OME PAGE P RINT. High Flow. Aluminum Bodies Air and Inert Gas 3/4" to 3" NPT.

Comfort. Sewage Treatment Plants. Petrochemical Facilities, Oil Rigs. Unattended Pumping Stations. Chemical Storage and Handling Facilities

SG1000A Slide Gate Sensor Slide Gate & Valve Position

Cable Supports. Requirements for Cable Supports in the National Electrical Code reads as follows:

G1-24. Applications UL listed for marine type electric fixtures--outside. Ideal in Class I, Div. 1 and 2 installations

Bourdon Tube Pressure Switches

A Full Line of Low Voltage IEC Motors In-Stock

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

Basins, Floats & Accessories

EDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit.

Transcription:

CSA - Class I Div. 1 - Groups C & D * CSA - Class I Zone 1 - Groups IIA, IIB * * Applies to GUI boxes only Explosion Proof & Hazardous Area Junction Boxes Features: Heavy-duty copper free (below 0.04%) cast aluminum construction. Explosion proof boxes available with internal or external cover threads. A choice of three covers offered: blank, sealing (explosion proof only) and hanger. Hazardous area box is standard with screw down cover. All models available with four standard ½ or ¾ npt. hubs (5 th hub in back optional). Models standard with internal mounting rail for optional terminal blocks. External mounting feet for easy installation. Hub height allows the installation of cable connectors without the use of spacers Cover gasket allows for the use of the box in watertight or wash-down applications (Type 4). Applications: Pulp and paper mills Mining facilities Gas processing plants Grain handling facilities Oil drilling rigs (land and offshore) Oil refineries Bulk storage facilities Chemical manufacturing and processing plants Page 11

GUI Explosion Proof Junction Box CSA - Class I Div. 1 - Groups C & D * CSA - Class I Zone 1 - Groups IIA, IIB * Catalog Number Logic GUI 4-1 - B XX (1) (2) (3) (4) (5) (1) Junction Box Type GUI Explosion proof, watertight, aluminum junction box with universal hubs and internally threaded cover. 4) Covers B - Blank cover P1 - Pendant hanger cover (1/2 npt.) P2 - Pendant hanger cover (3/4 npt.) S - Sealing cover (2) Number of Hub Entries 4-4 entries (2 pipe plugs supplied) 5-5 entries (additional back hub entry) (3 pipe plugs supplied) (3) Hub Size 1-1/2" npt. 2-3/4" npt. (5) Options CR - Corrosion resistant polyester powder-coat paint. TB*- Terminal block #10 awg. 600 VAC max. c/w mounting rail. *add suffix for number required ( 6 max.) Dimensions & Accessories 4 1 /16 (10.3) 0.275 (2.1) Part Type Blank cover Per Weight lbs. (kg.) 4 1 /16 (10.3) 3 1 /4 (.3) 3 1 /4 (.3) (2.5) 4 1 /16 (10.3) 2 11 /16 (6.3) Pendant Cover 5 / (1.59) 1-7/16 (3.65) GUI-BC 5 GUI-HC 5 0.67 (0.3) 0.75 (0.34) Per *Weight Per Each lbs (kg.) Size of ft 3 ( m 3 ) 5 2.0 (0.92) 0.4 (0.012) Sealing Cover 1-5/ (4.1) GUI-SC 5 0.77 (0.35) Page 119

JUS Hazardous Area Junction Box Catalog Number Logic JUS 4-1 - B XX (1) (2) (3) (4) (5) (1) Junction Box Type JUS Hazardous area, watertight, aluminum junction box with universal hubs and screw cover. (2) Number of Hub Entries 4-4 entries (2 pipe plugs supplied) 5-5 entries (additional back hub entry) (3 pipe plugs supplied) (3) Hub Size 1-1/2" npt. 2-3/4" npt. (4) Covers B - Blank cover D - Deep blank cover P1 - Pendant hanger cover (1/2 npt.) P 2 - Pendant hanger cover (3/4 npt.) (5) Options CR - Corrosion resistant polyester powder-coat paint. (available for aluminum or malleable iron) TB* - Terminal block #10 awg., 600 VAC max. c/w mounting rail. *add suffix for number required (6 max.) Dimensions & Accessories 3¾ (9.5) Part Type Blank cover Per Weight lbs. (kg.) 3¾ (9.5) (2.54) 2 (5.1) 3/ (0.95) JUS-*BC 5 0.5 (0.23) Deep blank cover 4. (10.4) 4½ (11.4) 0.275 DIA. 11/ (2.6) JUS-*DC 5 0.75 (0.34) Per *Weight Per Each lbs (kg.) Size of ft 3 ( m 3 ) 5 1.6 (0.73) 0.4 (0.012) Pendant hanger cover 17/16 (3.65) JUS-*HC 5 0.6 (0.31) Page 120

JUS-N Non Metallic Junction Box (General Use only, Product is not CSA or UL approved) Catalog Number Logic JUS4-2 - B (1) (2) (3) (4) (1) Junction Box Type JUS Watertight, non metallic junction box with universal hubs and screw cover. (2) Number of Hub Entries 4-4 entries (2 pipe plugs supplied) (3) Hub Size 2-3/4" npt. (4) Covers B- Blank cover ( Can be field tapped to ¾ ) Dimensions & Accessories (non-metallic) 4¾ (12.1) Part Type Blank Cover Per Weight lbs. (kg.) 1 3 /16 (3.0) 2 (5.1) 4¾ (12.1) 3/ (0.95) JUS-NBC 5 0.5 (0.23) Gasket 0.34 DIA. 4 5 / (11.7) 4 3 /16 (10.6) JUS-G 10 0.1 (0.05) Per *Weight Per Each lbs (kg.) Size of ft 3 ( m 3 ) 5 1.2 (0.55) 0.4 (0.012) Note: Covers include gasket and four screws for mounting to box. * Weight shown is for box complete with blank cover. Page 121

HFS Hazardous Area Junction Box Ordering Guide Catalog number includes cover (Not Shown) Box Type Hub Size Catalog No. Std. Pkg. Box Type Hub Size Catalog No. Std. Pkg. HFS-1BC HFSL-1BC HFS-2BC HFSL-2BC HFSA-1BC HFSLA-1BC HFSA-2BC HFSLA-2BC HFSC-1BC HFSR-1BC HFSC-2BC HFSR-2BC HFSCA-1BC HFST-1BC HFSCA-2BC HFST-2BC HFSCT-1BC HFSX-1BC HFSCT-2BC HFSX-2BC Note: For non hazardous location FS box drop prefix H and suffix -BC (blank cover) from catalog b Page 122

HFS Hazardous Area Junction Box Accessories Description Weight per carton lbs. (kg.) per carton FSBC Blank cover c/w gasket 0.26 (0.12) 20 FSRG Weather tight gasket 0.07 (0.03) 20 FSDP* FS box device bracket (set of 2) 0.045 (0.02) 20 Note: Covers include gasket and four screws for mounting to box. * FSDP device bracket must be ordered if any switch or receptacle requires to be mounted on FS box. 2 ¼ (.9) Dimensions 27/ (7.3) 5 ¾ (14.6) 5 ¼ (21.0) (2.5) 23/ (6.0) 43/ (11.1) (2.5) 3 (7.6) 6¼ (15.5) Page 123