Lucalox Standard. GE Lighting. Product information. Applications areas

Similar documents
Lucalox Standard Tubular Clear Product Code * * 11678* LU150/100/ HO/T/E40 LU150 /100/40

Lucalox XO High Pressure Sodium Lamps with improved reliability Lucalox TM XO Tubular Clear 50W, 70W, 100W, 150W, 250W, 400W & 600W

GE Lighting DATA SHEET. Product information. Features. Applications

Lucalox PSL. GE Lighting DATASHEET. Lucalox PSL Tubular Clear 230V 250W, 400W, 600W and 750W Lucalox PSL Tubular Clear 400V 600W and 750W

Arcstream Double Ended

Multi-Vapor Metal Halide Lamps

ConstantColor CMH Open Rated

ConstantColor CMH Tubular Clear

ConstantColor CMH PAR 20 & PAR 30 Ceramic Metal Halide Lamps 20W, 35W and 70W

ConstantColor CMH High Wattages

ConstantColor CMH TD. GE Lighting DATA SHEET. Double Ended Ceramic Metal Halide Lamps 35W, 70W and 150W. Product information.

ConstantColor CMH Supermini

ConstantColor CMH Mini G8.5

ConstantColor CMH Supermini

T5 Watt-Miser Linear Fluorescent lamps

ConstantColor CMH PAR 20 & PAR 30 Ceramic Metal Halide Lamps 20W, 35W and 70W

GE ConstantColor CMH TM CMH SuperMini 20W & 35W

ConstantColor CMH Supermini Ultra

GE ConstantColor CMH StreetWise

ConstantColor CMH MR16

Spiral T2 10,000 & 8,000 hours

ConstantColor CMH. GE Lighting DATA SHEE T. Ceramic Metal Halide Lamps Single Ended G12 Product Information. Lamp technology. Single ended format

ConstantColor CMH Mini G8.5

Biax D and D/E. Compact Fluorescent Lamps Non-Integrated 10W, 13W, 18W and 26W. GE Lighting DATA SHEET. Product information.

ConstantColor CMH G8.5 and G12 Ultra

Biax D and D/E. GE Lighting DATA SHEE T. Compact Fluorescent Lamps Non-Integrated 10W, 13W, 18W and 26W

ConstantColor CMH MR16 Ultra

ConstantColor CMH MR16

GE Lighting. Single Ended G8.5 Ceramic Metal Halide Lamps Product Information for Original Equipment Manufacturers

LED T8 BP. GE Lighting. Tubular lamps DATA SHEET. Specification Features. Product information. Applications. IEC standards

POWERSTAR HQI -T W Metal halide lamps with quartz technology for enclosed luminaires

2D and 2D Watt-Miser. GE Lighting DATA SHEET. Compact Fluorescent Lamps Non-Integrated 16, 21, 28, 38W 2D Watt-Miser and 55W 2D. Product information

HSI-HX / HSI-THX SA HSI-THX 400W 4K E40 SLV PRODUCT OVERVIEW DATA TABLE. Optical data

SHP-S/SHP-TS Super SA SHP-TS 70W/CL E27 SLV PRODUCT OVERVIEW DATA TABLE. Optical data

Infusion Module NPM Series

Energy efficient low voltage dichroic mirror halogen reflector lamps

Infusion Module M4500 Series High lumen LED lighting

Compact Fluorescent Lamps Non-Integrated

HCI-T 35 W/830 WDL PB

Infusion Module Gen2 M1000, M1500, M2000 and M3000 Series

2D Watt-Miser. GE Lighting DATA SHEET. Applications areas. Features. Lamp technology. Application areas

Infusion Module NPM Series

Albeo LED Luminaire Linear high bay lighting ABV Series

HIGH PRESSURE SODIUM. EYE Lighting Volume 6 Catalogue

Retrofit without Compromise

HCI-T 150 W/830 WDL PB

Lamps CERAMIC METAL HALIDE

Lumination LED Luminaires

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC EM STARK CLE

LAMPS - HIGH PRESSURE SODIUM

Product Description. MASTER HPI-T Plus. Quartz metal halide lamps with clear outer bulb

Solid State T8 tube is the smart alternative to a

HCI-TS 150 W/830 WDL PB

PHASED OUT. LED light engine / OLED LED linear / area. Module LLE G3 16x140mm 325lm ADV, LLE G3 16x280mm 650lm ADV Modules LLE ADVANCED

HCI-TT 250 W/830 SUPER 4Y

PHASED OUT. LED light engine / OLED LED compact. Module CLE G2 190mm 1500lm ADV EM Modules CLE

LED light engine / OLED LED compact

LED light engines LED linear / area. Module STARK QLE G3 SELECT Modules QLE EXCITE

LED modules LED linear / area

LED light engine / OLED LED compact. Umodule STARK CLE 360 CLASSIC EM STARK CLE

PHASED OUT. LED / OLED Light Engine LED linear / area. Umodule STARK LLE STARK LLE

LED light engine / OLED LED linear / area

LED modules LED linear / area

HCI-TT 250 W/830 SUPER 4Y

Colour Temp. Efficacy. Lumens CRI

GE Lighting. GE Lucalox. High Pressure Sodium Lamps

T5 versus T8 Fluorescent Lamps. The good, the bad, & the ugly about T8 and T5 lamps

LED light engine / OLED LED linear / area. Umodule STARK LLE-G CLASSIC STARK LLE

GE Lighting. Biax TM. Plug-in Compact Fluorescent Lamps ENERGY SAVING LIGHTING

PHASED OUT. LED light engine / OLED LED compact. Module STARK CLE , CLE CLASSIC Modules CLE

LED light engines LED linear / area

LED light engine / OLED LED linear / area. Module LLE PREMIUM CRI90 LLE PREMIUM

HaloGLS, HaloCandle and HaloSpherical lamps

Shatterfree fluorescent lighting

Philips MASTER LEDtube InstantFit Standard Output 1500mm

LED light engine / OLED LED linear / area

PHASED OUT. LED light engine / OLED LED linear / area. Module QLE G1 488x239mm 2500lm ADV-SE Modules QLE

Tunable White LED linear / area. Module LLE G2 PREMIUM LLE PREMIUM

LED light engine / OLED LED compact

VIALOX NAV-T SUPER 4Y

PHASED OUT. LED light engine / OLED LED compact. Module STARK CLE CLASSIC / CLE CLASSIC Modules CLE

Linear Fluorescent Lamps

FL ballasts Electronic fixed output. PC T5 TOP lp, W PC TOP T5

Understanding Electronic UltraMax HID Ballasts

SLA DC. LED light engines ready2apply. Module SLA DC G2 50mm SNC Modules SLA ESSENCE

LED light engine / OLED LED linear / area. Umodule STARK LLE-G CLASSIC EM STARK LLE

HO CONSTANT 39 W/840. Product datasheet. LUMILUX T5 HO CONSTANT Tubular fluorescent lamps 16 mm, high output, Constant

Dreamer Series. LED bulb A60. Product benefits. Product features. Product datasheet

Replacement. Metal Halide OB150S. Product Wattage CCT Total Lumen Efficacy Voltage Frequency Base Installation Angle

LED. High-performance streetlight. -afortable and reliable

LED light engines LED linear / area

Compact Fluorescent Lamps Integrated

SubstiTUBE Value EM T8 (AUS Fighter Tube) ST8V-0.6M ST8V-1.2M ST8V-1.5M

SON( Plus)(-H)(Comfort) SON-T 1000W. SON-T Plus/SON-T Agro

LED light engines LED linear / area

PHASED OUT. LED light engine / OLED LED linear / area. Umodule STARK LLE umodule LLE ADVANCED

POWERSTAR HQI-T. Product family datasheet. Metal halide lamps with quartz technology for enclosed luminaires

FL ballasts Electronic fixed output. PC BASIC sl, 4 28 W PC BASIC

Technical information. Lamp data Light tubes

LED light engines LED linear / area

Transcription:

GE Lighting Lucalox Standard High Pressure Sodium lamps Tubular Clear & Elliptical Diffuse 70W, 100W, 150W, 250W, 400W and 1000W DATA SHEET Product information From GE s invention of HPS lighting in 1965 to today s advanced sources, GE Lucalox High Pressure Sodium lamps have led the way in quality and innovation. GE s exclusive amalgam reservoir design works to increase life expectancy and improve lumen maintenance. With efficiencies approaching 137 lumens per watt, GE Lucalox Standard lamps are the most efficient light source available with acceptable colour rendering. High efficiency results in lower operating costs and thus a lower electricity bill. Applications areas Commercial areas / city beautification / architectural Most Lucalox lamps have an average rated life of up to 28,500 hours. Long life means lower replacement and maintenance costs. *Non EU product

Basic data Lucalox Standard Tubular Clear Product Code 46221 93767 44244* 97241 22453* 93010296 11678* 97240 45751 85886 Product Description Lucalox Standard Elliptical Diffuse Product Code 46217 93766* 44245* 44052* 44057* Product Description LU 70/90/ MO/T/E27 1/25 LU 70/90/MO /D/E27 1/12 LU100/100/ MO/T/40 LU150/100/ 100/40 LU150/100/ HO/T/E40 LU100/100/MO /D/40 LU250T/40 LU150/100 /D/40 LU250/HO/T/ E40 LU400/T/40 Nominal [W] 70 100 150 250 400 Rated [W] 71 104 149 251 404 Weighted Energy Consumption [kwh/1000 hrs] 77.79 114.72 163.68 276.44 444.01 Volts [V] 90 100 100 100 100 Cap E27 E40 E40 E40 E40 Nominal Lumen [lm] 5,800 9,200 14,500 26,000 48,000 Rated Lumen [lm] 6,180 9,230 14,620 26,690 48,090 Rated Lamp Efficacy [lm/w] 87 89 98 106 119 Energy Efficiency Class [EEC] A A+ A+ A+ A+ Mercury Content [mg] 10.0 13.3 16.4 16.4 15.8 Rated Average Life [h] 28,500 28,500 28,500 28,500 28,500 CCT [Ra] 2,000 2,000 2,000 2,000 2,000 Ambient Temperature [ C] 25 25 25 25 25 Bulb Soft Hard Hard Hard Hard Mass Weight (g) 65 130 175 195 250 Operating Position Universal Universal Universal Universal Universal *Non EU product Minimum Starting Temp. [ C] -40-40 -40-40 -40 LU250/ D/40 LU400/HO/ LU1000/110/ T/40 4pk Nominal [W] 70 100 150 150 250 250 400 400 1,000 1,000 Rated [W] 71 99 149 157 252 258 393 404 970 1,000 Weighted Energy Consumption [kwh/1000 hrs] LU400/ D/40 LU1000/40 77.98 107.57 163.71 172.70 276.78 283.42 431.83 444.40 1067.10 1100 Volts [V] 90 100 100 100 100 100 100 100 110 250 Cap E27 E40 E40 E40 E40 E40 E40 E40 E40 E40 Nominal Lumen [lm] 6,000 9,600 15,300 17,500 28,500 32,500 48,000 56,200 130,000 130,000 Rated Lumen [lm] 6,420 9,880 15,490 17,600 28,750 33,270 48,300 56,200 133,340 127,590 Rated Lamp Efficacy [lm/w] 91 100 104 110 114 129 123 135 137 128 Energy Efficiency Class [EEC] A+ A+ A+ A+ A+ A+ A+ A++ A++ A+ Mercury Content [mg] 10 13.3 16.4 12 16.4 20,0 15.8 20 21.1 24.8 Rated Average Life [h] 28,500 28,500 28,500 24,000 28,500 24,000 28,500 24,000 24,000 24,000 CCT [Ra] 2,000 2,000 2,000 2,000 2,000 2,000 2,000 2,000 2,000 2,000 Ambient Temperature [ C] 25 25 25 25 25 25 25 25 25 25 Bulb Soft Hard Hard Hard Hard Hard Hard Hard Hard Hard Mass Weight (g) 65 155 155 140 155 165 200 177 445 368 Operating Position Universal Universal Universal Universal Universal Universal Universal Universal Universal Universal Minimum Starting Temperature [ C] -40-40 -40-40 -40-40 -40-40 -40-40 Dimensions D B D Lucalox Standard - Tubular Clear Product Code 46221 93767 44244 97241 22453 93010296 11678 97240 45751 85886 [W] 70 100 150 150 250 250 400 400 1,000 1,000 A Length [mm] 156 211 211 211 260 260 278 283 374 383 B Arc Gap [mm] 35,5 40 55 47 65-86 81 150 233 C LCL [mm] 97 132 132 132±5 158 163 175 175±5 240 220±2 D Diameter [mm] 39 48 48 48 48 48 48 48 68 79 A C A Lucalox Standard - Elliptical Diffuse Product Code 46217 93766 44245 44052 44057 [W] 70 100 150 250 400 A Length [mm] 156 186 227 227 292 D Diameter [mm] 72 76 91 91 122 2

Survival rate and lumen maintenance Average lamp life & lumen maintenance is based on laboratory tests of a large number of representative lamps under controlled conditions, including operation at 11 hours per start on ballasts having specified electrical characteristics. The following conditions can reduce average lamp life and lumen maintenance: Frequent on/off switching High line voltage Vibration High ambient temperature within the fixture Ballast and ignitor characteristics Average rated life The survival of individual lamps or particular groups of lamps depends on these system conditions, and actual data may fall dependent upon the lamp operating conditions even below the lower limit (see Lamp survival graphs). For cost-of-light calculations involving these lamps, the following estimated operating times are suggested for 5 survival: Lumen maintenance Under the same controlled conditions, initial reference lumens refer to the lamp lumen output after 100-hours burning. Due to variations in systems and service conditions (in particular the burning cycle), actual lamp performance can vary from the reference lumen ratings. The lumen maintenance (light output during life) of individual lamps or particular groups of lamps may fall dependent upon the lamp operating conditions even below the line (see lumen maintenance graphs). Survival rate of HPS Lucalox Standard lamps (70-100W) Lumen maintenance of HPS Lucalox Standard lamps (70-100W) 28,500 28,500 Survival rate of HPS Lucalox Standard lamps (150-400W) Lumen maintenance of HPS Lucalox Standard lamps (150-400W) 28,500 28,500 Survival rate of HPS Lucalox HO lamps (150-400W) Lumen maintenance of HPS Lucalox HO lamps (150-400W) 9 7 5 3

Survival rate of 1000W/110 standard HPS lamps Lumen maintenance of 1000W/110 standard HPS lamps Survival rate of 1000W/40 standard HPS lamps Lumen maintenance of 1000W/40 standard HPS lamps 28,000 Electrical data Data is based on a nominal lamp operating from a nominal choke (reactor) ballast with power factor correction. power is based on a typical commercially available ballast. Lamp data Volts ±15 [V] Nominal [A] Nominal [W] 70 90 0.98 70 1.45 100 100 1.2 100 1.45 150 100 1.8 150 1.45 250 100 3.00 250 1.45 400 100 4.6 400 1.45 1000 110 10.60 960 1.45 Crest Factor Circuit data (typical data of lamps with nominal voltage) Max. 4 (W) Factor Lagging Percentage 3rd Harmonic [μf] During Run-up Failed/ Hot Lamp 230V 240V 230V 240V 230V 240V 230V/240V 230V/240V 230V 240V 230V 240V All Types 70 0.40 0.40 83 86 0.90 0.90 14 10 0.45 0.42 0.72 0.75 100 0.54 0.52 113 114 0.91 0.91 15 12 0.64 0.60 0.87 0.90 150 0.83 0.80 171 172 0.90 0.90 15 20 0.91 0.84 1.45 1.50 250 1.35 1.30 275 276 0.89 0.89 15 30 1.58 1.48 2.17 0.30 400 2.20 2.10 426 427 0.84 0.85 12 40 2.80 2.60 2.79 3.00 1000 5.66 5.40 1,092 1,090 0.84 0.84 15 85 6.46 6.00 6.14 6.40

Circuit data (typical data of lamps with nominal voltage) Max. (W) Factor Lagging Percentage 3rd Harmonic [μf] During Run-up Failed/ Hot Lamp 230V 240V 230V 240V 230V 240V 230V/240V 230V/240V 230V 240V 230V 240V All Types 70 0.40 0.40 83 86 0.90 0.90 14 10 0.45 0.42 0.72 0.75 100 0.54 0.52 113 114 0.91 0.91 15 12 0.64 0.60 0.87 0.90 150 0.83 0.80 171 172 0.90 0.90 15 20 0.91 0.84 1.45 1.50 250 1.35 1.30 275 276 0.89 0.89 15 30 1.58 1.48 2.17 0.30 400 2.20 2.10 426 427 0.84 0.85 12 40 2.80 2.60 2.79 3.00 1000 5.66 5.40 1,092 1,090 0.84 0.84 15 85 6.46 6.00 6.14 6.40 Photometric data 100 Hours Lumens CCT [K] CRI [Ra] DIN5035 Class. 70 6,000 2,000 25 4 100 9,600 2,000 25 4 150 15,300 2,000 25 4 150 (HO) 17,500 2,000 21 4 250 27,000 2,000 25 4 250 (HO) 32,500 2,000 21 4 400 48,000 2,000 25 4 400 (HO) 56,200 2,000 21 4 1000 130,000 2,000 25 4 Relative intensity 120 100 80 60 40 20 0 Spectral power distribution Wavelength [nm] Run-up characteristics The graph shows typical run-up characteristics for a 250W Lucalox lamp. Time for the light output to reach 9 of the final value is determined by supply voltage and ballast design. Typical values are: 70 100 150 250 400 1,000 Run-Up (Mins) <4 4 4 5 3 6 Hot re-strike time All ratings re-strike within 1 minute following a short interruption in the supply. Actual re-strike time is determined by ignitor type, pulse voltage and cooling rate of the lamp. voltage Percentage of final value Typical run-up characteristics 1 1 Lumen Ulamp Ilamp Plamp 0 1 2 3 4 5 6 7 8 9 10 Time from switch on (minutes) Effect of supply voltage variations on performance Lamps are suitable for supplies in the range 220V to 250V 50/60Hz for appropriately rated series choke (reactor) ballasts. Supplies outside this range require a transformer (conventional, high reactance or CWA) to ensure correct lamp operation. Lamps start and operate at 1 below the rated supply voltage when the correct control gear is used. However, in order to maximize lamp survival, lumen maintenance and colour uniformity the supply voltage and ballast design voltage should be within ±3%. variations of ±5% are permissible for short periods only. This may be achieved by measuring mean supply voltage at the installation and selecting ballasts with appropriate settings. 5 Percentage of nominal value 1 1 1 Lumen Ulamp Ilamp Plamp 60 70 80 90 100 110 120 by Voltage

Control gear It is essential to use a ballast appropriate to the supply voltage at the luminaire. Typical wiring diagrams for control circuits incorporating superimposed or impulser ignitor and choke (reactor) ballasts are shown. Refer to actual choke and ignitor manufacturers data for terminal identification and wiring information. Typical impulser ignitor circuit Typical superimposed ignitor circuit Phase Ballast Phase Ballast Fuse HBC or MCB Ignitor Fuse HBC or MCB Ignitor B Lp N Neutral Neutral Lamp operating temperature limits 70W 100-1,000W Maximum cap temperature 210 C 400 C Maximum bulb temperature 250 C 250 C Luminaire voltage rise To maximise lamp life it is essential that luminaires are designed so that when lamps are enclosed lamp voltage rise does not exceed the following values: 70 100 150 250 400 1,000 Luminaire voltage rise (tubular) 5 7 7 10 12 20 Ballasts Lamps are fully compatible with ballasts manufactured for high pressure sodium lamps to IEC 60662. Ballasts should comply with specifications IEC 60922 and IEC 60923. Ballast Thermal Protection Use of ballasts incorporating thermal cut-out is not a specific requirement but is a good optional safety measure for installation. Ballast Voltage Adjustment Series choke (reactor) ballasts incorporating additional tappings at ±10V of the rated supply voltage are recommended. Alternatively a single additional tapping 10V above the rated supply voltage will ensure lamps are not overloaded due to excessive supply voltage. Ignitors Both Superimposed and Impulser type ignitors are suitable. It is recommended that only GE approved ignitors are used. Ignitors should comply with specifications IEC 60926 and IEC 60927 and have starting pulse characteristics as follows. Voltage [kv] (1) Max. Voltage [kv] (2) Width [μs] (3) Repetition Rate (4) 70 1.8 2.3 1.95 1/1/2 Cycle 0.2 100 2.8 4.5 1.95 1/Cycle 0.2 150 2.8 4.5 1.95 1/Cycle 0.2 250 2.8 4.5 0.95 1/Cycle 0.2 400 2.8 4.5 0.95 1/Cycle 0.2 (1) When Loaded with 100 pf. (2) When loaded with 20pF. (3) At 9 peak voltage. (4) From ignitor into lamp during starting. Phase Angle: 60-90 el and/or 240-270 el. HF Peak [A] 6

Timed ignitors Use of a timed or cut-out ignitor is not a specific requirement, but it is a good optional safety feature for installation. The timed period must be adequate to allow lamps to cool and restart when the supply is interrupted briefly (see Hot re-strike time ). Safety warnings The use of these products requires awareness of the following safety issues: Warning During the production process, GE Lucalox lamps are start tested according to the requirements of the IEC 60662 Standards and will therefore be compatible with ignitors designed for lamps to this standard and which comply with the relevant ignitor Standards (IEC 60926 & 60927). Examples of commercial ignitor manufacturers are: BAG Turgi ERC May & Christe Parry Thorn Tridonic # Impulser type - approved only when used with a suitable ballast. MZN 70S (50/70W), MZN150S, MZN150SE-C (100/150W), MZN250SE (100/150/250W), ERC 640006 (100-400W) May & Christe ZG1.0SE (50/70W) ZG2.0SE (100/150W) ZG4.5SE (100/150/250/400W) Parry PB070#, PBE070, PXE070 (50/70W) PBO19#, PTH150# (150W) PB404# (250W/400W) G53503#, G53353.4#, G53353.2#, G53434 (50/70W) G53504#, G53511, G53476, G53455, ZRM2-ES, ZRM2-IS (50/70W) ZRM1.8ES/2 (100/150W) ZRM6-ES (100/150/250/400W) MZN400S(R) (100/150/250/400W) MZN400SU (100/150/250/400W) MZN1000S (1000W) PAE400, PXE400, PWE400(150/250/400W) G53250 (100/150/250/400W) G53282/B# (150/250/400W) G53316 (1000W) ZRM12-ES (1000W) Cable between ignitor and lamp The cable connected between the lamp and a superimposed ignitor Lp terminal, or the ballast when using an impulser ignitor, must be rated at a minimum 50/60Hz voltage of 1000V. Mineral-insulated cables are not suitable for connecting the lamp to the control gear. To achieve good starting superimposed ignitors must be adjacent to the luminaire. Cable capacitance of wiring between the ignitor Lp terminal and the lamp should not exceed 100pF (<1 metre length) when measured to adjacent earthed metal and/or other cables, unless otherwise stated by the ignitor manufacturer. When using impulser type ignitors longer cable lengths between ballast and lamp are normally permissible. Limits for particular ignitors are available on request from GE Lighting or directly from the ignitor manufacturer. capacitors for choke (reactor) circuits Factor Correction is advisable in order to minimise supply current and electricity costs. For 220-250V supplies 250V±1 rated capacitors are recommended as follows: 70 100 150 250 400 1,000 10μF 12μF 20μF 30μF 40μF 85μF www.gelighting.com and General Electric are both registered trademarks of the General Electric Company GE Lighting is constantly developing and improving its products. For this reason, all product descriptions in this brochure are intended as a general guide, and we may change specifications time to time in the interest of product development, without prior notification or public announcement. All descriptions in this publication present only general particulars of the goods to which they refer and shall not form part of any contract. Data in this guide has been obtained in controlled experimental conditions. However, GE Lighting cannot accept any liability arising from the reliance on such data to the extent permitted by law. Lucalox Standard Data Sheet October 2014