Model Name: 4 Position RPV-1

Similar documents
AKVdiesel. Automated kinematic Viscometer key features. Fully complies with ASTM D445. Two measuring positions. Remove cap and pour in sample

Dilute Solution Viscosity

LABORATORY Viscometers

breakthrough versatility

Stabinger Viscometer SVM 3001

Procedure for Koehler Digital Constant Temperature Viscosity Bath

Let us be your partners in the viscosity measurement

CANNON CAV 2000 Series Automatic Viscometers

For the fastest possible service, you can now reach Koehler via the Internet. On our website, you can:

SVM Stabinger Viscometer. ::: Viscometry at its best

ISOCAL - 6 Range Europa Venus Calisto

Petroleum Testing Equipment

A SURVEY OF OUR KNOW-HOW : PETROLEUM GLASSWARE VISCOMETER TUBES

MiniLab EL Series for High Performance Engine Development and Maintenance

Manual Kinematic Viscosity Bath Tamson TV12

REVOLUTIONIZE YOUR GAS DENSITY AND PURITY MEASUREMENT TECHNOLOGY

TSHR 7000 series TN-TS-TX analyzer

Q200. Aquamax FlashPoint. Q5800 MiniLab 53 MiniLab 153 MicroLab Q1000. Q100 Spectroil M. Q300/310 Q3000 Pat 940 Density 5

Manual Kinematic Viscosity Bath Tamson TV2000 & TV4000 ASTM D445, IP71, ISO 3104

Infinite F50 family Reliable. Validated. Compact.

Stabinger Viscometer Series. SVM Series

Infinite F50 family INNOVATIVE EIGHT CHANNEL ABSORBANCE READERS WITH ADVANCED LED TECHNOLOGY. 21 CFR Part 11* 98/79/EC IVD-D*

PMA 5. Pensky-Martens Flash Point Tester. ::: Volatility... Flammability

Innovation in cold behavior

MODULAR MELT FLOW: The First Step: Melt Flow Index (Weight Method) According to ASTM D 1238, ISO 1133 Method A and other equivalents

TESIGNG OF FUELS: VISCOSITY OF LIQUID FUELS

CFA. Carton Force Analyser

Phase Technology PPA-70Xi Pour Point Analyzer

orb effortless reactions Unrivalled quality» Intuitive design» Exceptional value

Phase Technology PFA-70Xi Pour & Freeze Point Analyzer

Preparing the New EuroLoop Liquid Flow Facility for Accreditation. Jos van der Grinten - NMi EuroLoop

Optidew Vision Optical Dew-Point Meter

Options. 1 Test Station, Type ZT V/50Hz V/60Hz V/60Hz V/60Hz

TSHR 6000 series TN/TS/TX analyzer

Instruments for the Analysis of Petroleum Products. Oxidation Stability

Stability, Linearity and Repeatability of Nitrogen Determination by Flash Combustion using Argon as Carrier Gas

Pressure Transmitter

VEHICLE COMPONENTS SUPPLY EXPERTS

Products for Asphalt Testing

CarePacs. Traceable Balance Testing for Secure Weighing Processes

Innovation in cold behavior

Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and Calculation of Dynamic Viscosity) 1

MB3600-HP10 Laboratory FT-NIR analyzer for hydrocarbon applications Pre-calibrated for blended gasoline, diesel, reformate and naphtha

Mobile air conditioning lubricants

Article: Sulfur Testing VPS Quality Approach By Dr Sunil Kumar Laboratory Manager Fujairah, UAE

USV Ultra Shear Viscometer

A Comparison of Boat Introduction and Direct Injection using the Thermo Scientific ipro 5000 Series Combustion Analyzer

MB3600-CH30 Laboratory FT-NIR analyzer for biodiesel applications Suitable for production optimization and product quality assessment

Determining the Ethanol Content of Denatured Fuel Ethanol Using Near Infrared. Gulf Coast Conference Patrick Ritz PAC LP

A Guide to Dry Block Calibration

Instruments for Chemical and Petroleum Products. Flash Point

Elemental Analysis Advanced

Fully Automated Standard Dispensers

Shriram Institute For Industrial Research, 14-15, Sadarmangala Industrial Area, Whitefield Road, Bangalore, Karnataka

MB3000. Versatile FT-IR analyzer designed for your industry The most reliable FT-IR, the lowest cost of ownership.

Phase Technology CPA-70Xi Cloud Point Analyzer

High-Tech Waterjet Cutting

english Series 1 The versatile rheometer concept

KONFORT 744 for CO2. Mercedes-Benz. KONFORT 744 is approved and recommended by:

ISO 4925 INTERNATIONAL STANDARD. Road vehicles Specification of non-petroleum-base brake fluids for hydraulic systems

Combustion Monitoring with Pressure Sensors.

Process Analyzer. Viscosity Index Analyzer Model P-950. Credible Solutions for the Oil and Gas Industry

THERMINOL 68. heat transfer fluid. High-temperature, low-viscosity fluid. -26 to 360 C. ( 14 to 680 F)

SFC-FID ASTM System. SFC-4000 Series SFC. Performance Innovation Reliability

Viscometry Rheometry. The Range. ::: Intelligence in Rheometry

THERMINOL RD. heat transfer fluid. Low-viscosity, medium-temperature fluid. -36 to 270 C. (--33 to 520 F)

Viscosity & Flash Point Standards For Reference, Validation, and Calibration

BRAKE FLUIDS HIGH PERFORMANCE FOR YOUR BRAKING SYSTEM

Viscosity & Flash Point Standards For Reference, Validation, and Calibration

VISCOBASE Synthetic Base Fluids. Economical solutions for high-performance automotive and industrial gear oils

Flash Point Process Analyzer

Residential power RSPW/GB-2008/1

Visco. Content viscometry. Applications for AVS measurement systems Page 176. ViscoClock Page 178. AVS 470 Page 180.

Excellence in gas analyzers since Over 180 years of JY optical experience. The expertise of Horiba combustion technology

Low cost EDXRF elemental analyzer

Global Automotive Scanner Market: Trends, Opportunities and Forecasts ( )

Electrical Stability Meter. Part No Instruction Manual. Updated 12/10/2015 Ver. 3.0

Model ED 400 Drying and heating chambers Classic.Line with natural convection

TOP SMART intelligent position monitor:

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

Monitor Chlorine in Crude at Sub-ppm Levels

Portable TOC Analyser for Stack Emissions

Model ED 400 Drying and heating chambers Classic.Line with natural convection

Pasve Rotary Retraction Valve

Pressure control solutions for your industry. Aerospace & Defense

POWDER TRANSFER CONTAINMENT VALVES

LR8123 Anti-Fret Primer. Corrosion inhibiting properties Rapid drying Anti-fret

Price List 2013 In-House Repairs and Calibration

Measuring Systems for Quality Control in Biodiesel Production. ::: Great People Great Instruments

On-Line NIR Analysis for Blending

Ball-on-Three Disks Test Machine

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

RHEOCHECK MD - Drive. Moving Die Rheometer controlled by Personal Computer.

MiniLab EL Series for High Performance Engine Development and Maintenance

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

STI OPENING THE DOORS TO TEMPERATURE PROGRAMMING- A NEW FRONTIER IN HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

BGD 160 series Portable Digital Viscometer INSTRUCTION MANUAL

Transcription:

Test Methods Model Name: 4 Position RPV-1 FULLY AUTOMATED POLYMER VISCOMETER to determine Relative Viscosity Inherent Viscosity Specific Viscosity Reduced Viscosity Kinematic Viscosity Dynamic Viscosity Intrinsic Viscosity Limiting Viscosity Number Molecular Weight K Value Degree of Polymerisation.and others ASTM D 789, ISO 307, ASTM D 4603, ASTM D 2857, ASTM D 1795, SCAN CM15:99, TAPPI T230-OM94, ASTM D 1243, USP<911> Viscosity, ISO 1628 The software is updated regularly taking into account new methods or customer specific requests. Therefore if your method is not mentioned in the above list then please contact us. Main Features 4 independent automated viscometers allows simultaneous measurement of 4 samples Accurate measurement of flow times to 0.001 using sensors Automatic calculation of results Automatic cleaning of viscometers and filling stations Pre-programmed with ASTM/ISO Test Methods Advantages Simple & Safe to use Improves accuracy Saves operator time Reduces exposure to hazardous chemicals Compliance with test methods

Description Typical Measurement Routine Samples are poured into the viscometer through the unique RPV Funnel Filling Station. Sample data is entered and the Start Test button pressed. After a short thermal equilibrium period, the flow time is measured automatically. Repeat flow times are automatically measured if required. Automatic Calculations, Results Database & LIMS Following a successful flow time measurement the RPV software performs many automatic calculations. Results are printed and/or stored in the user configurable results database for review at a later date. Results can also be exported automatically for use by a LIMS system. Automatic Safe-Vac Cleaning Viscometer tubes are cleaned out automatically after the measurement process has been completed. The RPV uses a safe-vac closed loop solvent and vacuum system. A cleaning routine can be set up using two or three solvents. The first solvent is always miscible with the polymer, followed by a second cleaning solvent (if required) and then a drying solvent. The RPV-1 software optimises cleaning and drying cycles. This ensures that each viscometer tube is properly cleaned and dried, eliminating the risks of sample or solvent contamination. Materials of construction & design The RPV-1 modules are assembled using components, which are highly chemically resistant all wetted parts are manufactured out of PTFE or glass. The RPV-1 case is covered in a tough chemical resistant coating, which is splash resistant to acetone and formic acid.

Thermostatic Stirred Liquid Bath The RPV-1 utilises a highly stable and uniform stirred liquid bath in order to control temperature of the sample to within + 0.005 o C of the required temperature set point. This degree of temperature control is essential in order to obtain accurate flow time measurements. ASTM Ubbelohde, Low Volume viscometers (or optional Cannon Fenske Routine) ASTM Ubbelohde viscometers are the most accurate viscometers available for automation purposes. The RPV-1 uses a standard ASTM specification tube with the option of a small sample volume. Viscometers are supplied with ISO 17025 certificates of calibration, issued by the PSL Calibration Laboratory, accredited by UKAS. Flow time measurement & nir detection system Viscometers are held in a measuring stand, which has sophisticated near Infra Red sensors nir. Flow times are measured accurately within 0.001 seconds. The use of nir sensors also allows the determination of opaque and coloured samples, such as those containing Titanium Dioxide (TiO 2 ). Software Calculator Tool The RPV-1 software has a calculator tool, which enables the operator to make calculations on data. This enables the operator to validate calculations and recalculate old data. Windows 98 & Windows XP Pro compatible The RPV-1 software is compatible with all versions of windows from Windows 98 to Windows XP Professional. RPV-1 Foreign Language Option The RPV-1 software can be supplied in different language options including French & Finnish as well as any others on request. Service Service & Manuals The RPV modules have been designed with service in mind. The modular configuration of modules allow for easy replacement or upgrading. Software diagnostic screens assist in identifying system or component faults. An engineer mode, allows a trained person, to control and activate valves and cleaning routines manually.

Specification Temperature range ( o C): 15 to 135 Temperature stability typical ( o C): +/-0.01 Flow time determinability.: <0.1% 10 measurements, mother liquor test, RV Nylon, ASTM D789, 50.0, standard deviation is less than 0.1% 10 measurements, separate samples, IV PET, ASTM D4603, 0.820, standard deviation is less than 0.4% 16 measurements per hour, typical. Typical Applications Pulp, Paper & Microcrystalline Cellulose, according to ASTM D1795 and SCAN CM15:98, TAPPI T230-OM94 Nylon according to ASTM D789 [HIGH CONCENTRATION] Nylon according to ISO307[LOW CONCENTRATION] PET according to ASTM D4603 PET in OCP [Orthochlorophenol] PET in Phenol/Dichlorobenzene Models Available 2 Position 4 Position 2 Position with Autosampler Basic PSL Testing Laboratory Take advantage of Poulten Selfe & Lee s Testing Laboratory. Send us a sample for correlation with your own laboratory. The cost of analysis is very competitive and we can offer a wide range of different test methods. Full method details are supplied if required. Please contact us for more information

Related Products Non-toxic Mercury Free Thermometers The PerformaTherm thermometers meet the requirements of ASTM E 2251, which means they can be used for ASTM methods in place of their mercury equivalent. Save time and money, improve safety and help the environment by changing to PerformaTherm. Contact Details RHEOTEK USA North & Central America Tel.: +1 502 225 0093 Fax: +1 502 225 4093 RHEOTEK Middle East Middle Eastern Region Arabian Technical Trading Est. Tel.: +966 3834 1924 Fax:+966 3834 2071 RHEOTEK Europe Belgium, France, Holland & Germany Tel.: +32 81 211877 Fax: +32 81 211877 rheotekeurope@hotmail.com RHEOTEK Brasil Brasil dpunion Instrumentação Analîtica e Cientîfica Tel.: +55 11 5011 8411 info@dpunion.com.br RHEOTEK UK UK & Rest of the World Poulten Selfe & Lee Tel.: +44 1621 787100 Fax: +44 1621 787175 Last updated 4/11/2003