rev gp-a 7.0.00 GP3/4 Mini Panels GP8-4 Standard-Size Panels DESCRIPTION Provide power and dimming for up to 44 load circuits. Control any light source, including full-conduction non-dim. Models available for: 00-7V, 0-40V (non CE), 30V (CE), and 77V. 3 to 44 circuits. Different feed types and breakers. work with: GRX-4000 Control Units GRAFIK 5000 and 6000 Systems LP Dimming Panels XP SoftswitchTM Panels DMX5 dimming systems via the LINKTM option. Get a Panel Fast! LISA (Lutron Integrated System Advantage) Program ships standard Panels 3 to 5 working days from receipt of approved drawings. GP36 Large-Size Panels GP48-44 Large-Size Panels
rev gp-a 7.0.00 SPECIFICATIONS Standards UL Listed (Reference: UL File 407). Complies with ISO-9000, CSA, NOM, or CE (where appropriate). Power Input power: 00-7V, 0-40V (non CE), 30V (CE), and 77V. All voltages 50/60Hz, phase-to-neutral. Branch Breakers: UL-rated thermal magnetic. Protected by bypass jumpers. AIC ratings: 00-7V 0,000 0-40V 6000 30V (CE) 5,000 77V 4,000 Lighting strike protection: Meets ANSI/IEEE standard 6.4-980. Can withstand voltage surges of up to 6000V and current surges of up to 3000A. 0-year power failure memory: Automatically restores lighting to scene selected prior to power interruption. Sources/Load Types Operates these sources with a smooth continuous Square Law dimming curve or on a full conduction non-dim basis: Incandescent (Halogen)/Tungsten Magnetic Low Voltage Transformer Electronic Low Voltage Transformer Lutron Electronic Fluorescent Dimming Ballasts Magnetic Fluorescent Lamp Ballasts Operates HID sources on a full conduction non-dim basis. Reverse-phase control transformers require an ELVI Power Interface. Check phase with transformer manufacturer. Dimming Cards 6A continuous rating. UL-listed specifically for each light source. RTISSTM filter circuit technology compensates for incoming line voltage variations: No visible flicker with +/-% change in RMS voltage/cycle and +/-% Hz change in frequency/second. Arcless-relay air gap-off switches (one per load circuit): Ensure open load circuits when off function selected from Wallstations or Control Units. Eliminate arcing at mechanical contacts when loads are switched. Filter chokes Provide a rise time of at least: 350µSec as measured 0-90% of load current waveform at 50% dimmer capacity 55µSec as measured 0-00% of load current waveform at 50% dimmer capacity 400µSec as measured 0-90% of load current waveform at 00% dimmer capacity 600µSec as measured 0-00% of load current waveform at 00% dimmer capacity All measurements are recorded at a 90 degree conduction angle. At no point in the waveform can the rise time slope exceed a rate of 300mA per µsec. WHAT A MODEL NUMBER TELLS YOU Standard Prefix for GP Dimming Panels Feed Type for Ø, W 3 for Ø, 3W 4 for 3Ø, 4W Branch Breaker Number of amps Internal: Prewired by Lutron. System communications: Low-voltage Class (PELV) wiring connects Dimming Panels to other components. Line (mains) voltage: Feed, load, and control circuit wiring only. No other wiring or assembly required. Setup selector electronically assigns circuits to zones and sources. Permits reassignment of zones and sources without rewiring. Physical Design Enclosure: NEMA-Type, IP-0 protection; #6 U.S. Gauge Steel. Indoors only. Weight: 30-300 pounds (4-590kg). Mounting: Surface mount only. Allow space for ventilating. Environment/Heat Dissipation Patented, ribbed aluminum heat sink base cools Panel by convection. No fans. 3-04 F (0-40 C). Relative humidity less than 90% non-condensing. Region Suffix no code for 00-7V AU for 0-40V CE for 30V JA for 00V G P - 4 0 4 I S - 0 - A U C G P - Number of Load s Voltage 0 for 00-7 40 for non CE 30 for CE 77 Panel Breaker ML for Main Lugs Only Mxx for Main Breaker with xx = breaker size in amps IS for Isolator Switch Custom Panel Suffix shows that this Panel includes special options
rev gp-3a 7.0.00 GP3/4 MINI MODELS Only standard Panels listed. Consult Lutron for options. 00-7V Power GP 3 GP 4 MODELS AVAILABLE FOR... NUMBER OF MAXIMUM PANEL FEED/BRANCH CIRCUITS FEED TYPE FEED CIRCUIT BREAKERS Ø, W 45A 5A 60A 0A Ø, 3W 3Ø, 4W 30A 40A 5A 0A 5A 0A 5A 0A Feed 0A 5A Through 0A 0A 77V Power GP 3 GP 4 MODELS AVAILABLE FOR... NUMBER OF MAXIMUM PANEL FEED/BRANCH CIRCUITS FEED TYPE FEED CIRCUIT BREAKERS Ø, W 60A 3Ø, 4W 0A Feed Through 0A 0A 0A 30V (CE) Power GP 3 GP 4 MODELS AVAILABLE FOR... NUMBER OF MAXIMUM PANEL FEED/BRANCH CIRCUITS FEED TYPE FEED CIRCUIT BREAKERS Ø, W 30A 3Ø, 4W 0A Feed Through 0A 0A 0A 0-40V (non CE) Power GP 3 GP 4 MODELS AVAILABLE FOR... NUMBER OF MAXIMUM PANEL FEED/BRANCH CIRCUITS FEED TYPE FEED CIRCUIT BREAKERS Ø, W 48A 3Ø, 4W 6A Feed Through 0/6A, 5/A continuous load rating. Breakers located in distribution panel supplied by others. 6A 6A 6A WIRE SIZES GP 3 Feed Power (Hot/Live) wires connect directly to Branch Breakers: 00-7V 77V 0-40V 30V (CE) #4 AWG (.0mm ) to #0 AWG (4.0mm ) #8 AWG (.0mm ) to #4 AWG (5mm ) 30V (CE) MAINS CE Panels are listed as appliances. Distribution Panel must provide a main circuit breaker that does not exceed Panel Rating. Neutral wire connects to Neutral Lug: #4 AWG (.0mm ) to #8 AWG (6.0mm ) GP 4 Feed Through Power (Hot/Live) and Neutral connect to Terminal Blocks #4 AWG (.0mm ) to #0 AWG (4.0mm ) GP 3/4 Load Connect to Terminal Blocks #4 AWG (.0mm ) to #0 AWG (4.0mm )
rev gp-7a 7.0.00 DIMENSIONS FOR GP3/4 MINI PANELS Top View 5 /8" (30mm) 3 5/8" (9mm) 6 /4" (60mm) 5/8" (4mm) Class (PELV) Left Side View Front View 9 5/8" (44mm) 3/6" (8mm) Right Side View 5 /4" (30mm) 8" (457mm) 9 /" (495mm) /8" (537mm) /8" (9mm) /8" (9mm) 3/4" (70mm) " (79mm) Bottom View Keyhole accepts a maximum of /4" (6mm) mounting bolt. #0 M6 recommended. 3/4" (70mm) Load 3/4" (70mm) /" (38mm) 5 /" (40mm) /" (38mm) Feed
rev gp-a 7.0.00 MOUNTING FOR GP3/4 MINI PANELS Surface mount indoors. Panel generates heat! Mount only where ambient temperature is 3-04 F (0-40 C). This equipment is air-cooled. Do not block vents or you will void the warranty. Leave " (3cm) clearances above, below, and in front of Panel. No clearance necessary on sides. Reinforce wall structure for weight and local codes. GP3/4 Front View Class (PELV) GP3/4 Side View " (3cm) minimum top and front PANEL MAXIMUM WEIGHT BTUs/HOUR (WITHOUT PACKAGING) GP3/4 685 30 lbs (4kg) Terminal Blocks for Load s Branch Breakers Mount Panels where audible noise is acceptable. (Panels hum slightly and internal relays click.) Mount Panels so line (mains) voltage wiring is at least 6 feet (.8m) from sound or electronic equipment and wiring. Mount Panel within 7 of true vertical. Load Feed Raceway " (3cm) minimum Maximum Feed and Wire Sizes Consult Overview page. Water damages Panels! Install Panels in a location where they won't get wet.
rev gp-6a 7.0.00 GP3 MINI WIRING OVERVIEW Control Typical Load Bypass Jumpers! Do Not Remove DH SH H DH SH H DH 3 SH 3 H 3 Branch Breakers Dimmed Hot/Live Neutral Load Terminal Block () #4 AWG (.0mm ) to #0 AWG (4.0mm ) () #4 AWG (.0mm ) to #0 AWG (4.0mm ) Neutral Lug Feed Tips! You wire the GP3 Mini similar to wiring a lighting Distribution Panel. You run feed and load wiring. No other wiring or assembly required. You can use the GP3 Mini to provide temporary lighting. Wire all loads. Do not remove the bypass jumpers that protect the Dimming Modules. Use Branch Breakers to switch lights on and off. Neutral 00-7V #4 AWG (.0mm ) to #/0 AWG (70mm ) 0-40V #4 AWG (.0mm ) to 30V (CE) #8 AWG (6.0mm ) Power (Hot/Live) 00-7V #4 AWG (.0mm ) to #0 AWG (4.0mm ) 0-40V #8 AWG (.0mm ) to 30V (CE) #4 AWG (5mm )
rev gp-0a 7.0.00 00-7V AND 77V LOAD CIRCUITS (GP3-44) All Load Types except Lutron Hi-lume or Eco-0TM (ECO-Series) Fluorescent Dimming Ballasts GP Dimming Panel N Neutral (White) Use Dimmed Hot (DH) for all loads including Non-Dim. Use Switched Hot (SH) only with Lutron Fluorescent Dimming Ballasts. Dimmed Hot (Orange) DH SH H Load All Load #4 AWG (.0mm ) to #0 AWG (4.0mm ) Bypass Jumper! Do Not Remove Load Terminals Lutron Hi-lume or Eco-0 (ECO-Series) Fluorescent Dimming Ballasts GP Dimming Panel Where Neutral is Located Consult Overview page for the type of panel your working on. N Neutral (White) Red Load Dimmed Hot (Orange) Switched Hot (Black) Hi-Lume or Eco-0 (ECO) Ballast Red Blue Blue DH SH H Ground Load Terminals Load s with Emergency Battery Pack GP Dimming Panel Consult Lutron for approved manufacturers of emergency ballasts. Lutron Hi-lume -lamp, 0VAC Dimming Ballast shown. Wire colors may vary depending on emergency ballast manufacturer. N Neutral (White) Dimmed Hot (Orange) Switched Hot (Black) Dimming Ballast Blue Blue Red Red Blue Blue/White Yellow Yellow/Black Red Emergency Ballast To Unswitched AC Black (77V) Orange (0V) White To Neutral DH SH H Yellow Lamp Lamp (Emergency) Battery Connector Indicator Light Load Terminals
rev gp-3a 7.0.00 LOW-VOLTAGE CLASS (PELV) WIRING (ALL MODELS) Pull low-voltage type Class wiring for system communications. Must be daisy-chained! Must run separately from line (mains) voltage. Series 4000 GRAFIK Eye The Class (PELV) wiring link for system communications must be less than 000 feet (600m). Dimming Panel Control Unit Control Interface Wallstations Panel-to-Panel wiring Include one extra #8AWG (.0mm ). Used as a sense line for emergency (essential) lighting. Class (PELV) wiring link has: Two # AWG (.5mm ) conductors for control wiring. One shielded, twisted pair #8 AWG (.0mm ) for data link. GRAFIK 5000/6000 Systems Class (PELV) wiring links for system communications can be up to 4000 feet (00m): Use the -RPTR Interface and GRX-CBL-46L cable for links between 000 feet (600m) and 4000 feet (00m). Wire as shown for links 000 feet (600m) and less. Dimming Panel Processor Panel Control Unit Control Interface Wallstations Power Panel Link Panel-to-Panel wiring Include one extra #8AWG (.0mm ). Used as a sense line for emergency (essential) lighting. User Interface Link to PC Wallstation Links Each Class (PELV) has: Two # AWG (.5mm ) conductors for control wiring. One shielded, twisted pair #8 AWG (.0mm ) for data link. If you use Lutron cable, you can use smaller-gauge wires. If a Class (PELV) wiring link is less than 500 feet (50m), you can use GRX-CBL-346S: - Two #8AWG (.0mm ) for control wiring. - One twisted, shielded pair #AWG (.65mm ) for data link. - No sense line included - add your own #8AWG (.0mm ). If a Class (PELV) wiring link is 500 to 000 feet (50 to 600m), you can use GRX-CBL-46L: - Two #AWG (.5mm ) for control wiring. - One twisted, shielded pair #AWG (.65mm ) for data link. - One #8AWG (.0mm ) for sense line between Panels. Lutron has also approved smaller-gauge cable from Belden, Liberty, Alpha, and Signature. Ask for Lutron GRAFIK Eye Cable.
rev gp-4a 7.0.00 CLASS (PELV) PANEL-TO-PANEL WIRING (ALL MODELS) To additional Power Panels 3,4 5 Control () # AWG (.5mm ) : Common : 4VFW Shield/ Data Link () shielded, twisted pair #8 AWG (.0mm ) 3: 4: () #8 AWG (.0mm ) 5: Sense Line Shield/ 3,4 To Lighting Controls or Processors 3 4 D 5 3 4 D 5 Common +4VFW Sense Data A OK Power Data B OK Link A Link B 3 4 D 5 C D SELECT CIRCUIT Common Common +4VFW Sense Data A OK Power Data B OK Link A Link B 3 4 D 5 C D SELECT CIRCUIT Common Dimming Panel Dimming Panel Notes:. Emergency Power: The additional #8 AWG (.0mm ) wire is a sense line from terminal 5 of another Panel. This sense line allows an Emergency (Essential) Lighting Panel to sense when Normal (Non-Essential) power is lost. If more than one Emergency Lighting Panel needs to sense off a specific Normal Panel. You may have to run a dedicated wire between each pair of Normal (Non-Essential) and Emergency (Essential) panels.. Shield/: Connect shielding as shown. Do not connect to Ground (Earth) or Selector. Connect the bare drain wires and cut off the outside shield. CLASS (PELV) TERMINAL CONNECTIONS Each low-voltage Class (PELV) terminal can accept only two #8 AWG (.0mm ) wires. Two # AWG (.5mm ) conductors won't fit. Connect as shown. (4) # AWG (.5mm ) 3 4 D 5 Common 4VFW Data A OK Sense 3 4 D 5 SELECT CIRCUIT A Link Power Link B Comm C Data B OK D
rev gp-5a 7.0.00 OPTIONS Consult Lutron for ordering information, model numbers, and ship times. Dimensions and wiring may change based on options chosen. OPTION DESCRIPTION APPLICATION Custom Main Lutron custom sizes Panels main breakers to meet job s Jobs with special load requirements. Breakers load requirements. Double Lug Sets Allows Panels to handle up to 5A feeds. You want a single feed but need multiple. Delta Power Allows Panels to accept Delta power feeds (phase-to-phase). Areas that have Delta Power. Available for 40V only. Limited to 0A, -pole circuits. Branch Protection Branch Breakers have higher AIC ratings than those on standard Panels. Panels can also have circuit breakers with special ratings such as: GFI (Ground Fault Interrupt) ELB (Earth Leakage Breaker) RCD (Residual Device). Lutron Allows Panels to operate fluorescent ballasts that meet Jobs with fluorescent ballasts that Ten Volt Module IEC 99 standards for 0-0V control including: require 0-0V, PWM, or DSI control. (TVM) Lutron s TVE ballasts 0-0V neon PWM fluorescent Tridonic DSI (Digital Serial Interface). The TVM can sink or source 5OmA (typically 5-50 ballasts) on each circuit. MRI Allows Panels to dim DC (direct current) lighting in MRI facilities or sound studios where Magnetic Resonance Imaging (MRI) facilities. standard lighting control equipment won t work because of RFI and EMI. Locking Covers Prevents accidental tripping of circuit breakers. Adds an Ideal for service corridors and public areas. additional.5 (57.mm) to the front of Panel. Available for GP8-GP4 only Link Allows a DMX5 theatrical console to operate When you need to control architectural Dimming Panels load circuits. lighting from a DMX5 theatrical console. Allows a GRAFIK Eye 4000 System to handle 8 zone When you need to mix architectural and (two links of 64 zones). theatrical lighting. Allows two GRAFIK Eye 4000 Systems to share When you have multiple systems but not the same Dimming Panel. enough space to hang Panels.