For installation into ductwork

Similar documents
Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

Pressure relief dampers

Type WG. External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS, AVAILABLE ALSO IN LARGE SIZES

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

Ceiling swirl diffusers

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

Ceiling swirl diffusers

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

Shut-off dampers. Type AKK. For contaminated air PD AKK 1

Ceiling swirl diffusers

Ceiling swirl diffusers with perforated face plate

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

Ceiling swirl diffusers with perforated face plate

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

Circular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

CAV controllers Type RN

Type AK FOR LOW-LEAKAGE SHUT-OFF. Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK

Slot diffusers for ceiling installation

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Multileaf damper with actuator

Heat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en

Type AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK

Type NAK. Gas-tight shut-off damper with pneumatic actuator

Floor diffusers. The art of handling air. Type FB. In aluminium and plastic

Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K

CONSTANTFLOW Volume Flow Controllers

Volume Flow Limiters Type VFL

Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R

5/9.2/EN/6. Volume Flow Limiter. Type VFL for insertion into air ducting. The art of handling air

TYPE EK-EU SMOKE CONTROL DAMPER

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

Parts and characteristics

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

Type WG-JZ COMBINATION WITH A MULTILEAF DAMPER. PÁGINA PRINCIPAL > Productos > Rejas para intemperie - compuertas de regulación

VAV TERMINAL BOXES TYPE: BA BT

Duct Nozzle Diffuser. L e

Homepage > Products > Control units > VARYCONTROL > VAV TERMINAL UNITS > Type TVR. Type TVR

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

INDEX. Chapter1 0. air master. Round Ceiling Diffusers

C O L M A N. Air Distribution JET DIFFUSERS DCJ SERIES DCJ SERIES

VARYCONTROL VAV Dual Duct Terminal Boxes

Slot diffusers, Round duct diffusers. IMP Klima

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

Adjustable Curved Vane Diffusers. Vanes are parallel to the width dimension Vanes are parallel to the height dimension

Type TVLK OPTIMISED FOR USE IN LABORATORIES AND ON FUME CUPBOARDS

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS

2/1/EN/3. Slot Diffuser. Type VSD15. with 15 mm wide diffuser face

Grilles Linear Grilles

SDV Vane Swirl Diffusers

Type TVZ. VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

Series HCD Airfoil Control Damper

Variable Air Volume Dampers

Front panel Perforated galvanised steel Stainless steel AISI 316 as option Casing Galvanised steel Stainless steel AISI 316 as option

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Type CF FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, FLEXIBLE ALUMINIUM CONSTRUCTION

Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

PRODUCT BROCHURE. Rectangular Displacement Diffuser RDW-FD RDW-FD : smartemp.com

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

Extract-air grille with ATK plenum box

Incorporating V2.0. Product spec >>> > Series DJ - Drum jet diffusers

Control units. Simple. Precise. Efficient. Control units LVC, TZ-/TA-Silenzio and VFL

Type VSD35. Nominal length up to 1500 mm: one spigot

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser

DFA - Conical Ceiling Diffuser. Halton DFA. Conical Ceiling Diffuser

2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Grilles Linear Grilles

Weather Louvre Test. Report 57668/1. Carried out for Seng Yoon Seng Holdings SDN. BHD. By Andrew Freeth. 14 January 2014

PH SERIES SINGLE DUCT ATU PERFORMANCE DATA

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

THB - Perforated Ceiling Diffuser. Halton THB. Perforated Ceiling Diffuser

1/8/EN/6. Floor Diffusers. Type FB. in aluminium and plastic

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser

Transcription:

X X testregistrierung Non-return dampers Type For installation into ductwork Non-return dampers prevent unwanted airflows against the intended airflow direction when the system is not in operation Maximum differential pressure: 100 Pa Casing with U-channel connection suitable for rectangular ducts Available in standard sizes and many intermediate sizes Non-return damper with formed aluminium blades for normal requirements; blades are fitted with seals for sound attenuation Casing and duct connection Optional equipment and accessories Installation subframe Powder coating (RAL or DB) Bearings PD 1

General information Type Page General information 2 Function 3 Technical data 4 Quick sizing 5 Specification text 6 Order code 7 Dimensions and weight 8 Product details 9 Installation details 11 Basic information and nomenclature 13 Application Application Type non-return damper for installation into ductwork Prevention of unwanted airflows against the intended airflow direction when the system is not in operation Blades close automatically when the system is shut down Maximum differential pressure 100 Pa Special characteristics Any intermediate sizes within the standard size range are available operating temperature: 20 80 C Maximum differential pressure: 100 Pa Non-return dampers are opened and closed by the airflow; no actuator is required Non-return damper with formed aluminium blades for normal requirements; blades are fitted with seals for sound attenuation Nominal sizes B: 200, 400, 600, 800, 1000, 1200, 1400, 1600 mm (intermediate sizes: 201 1599 mm in increments of 1 mm) : 215, 315, 415, 515, 615, 715, 815, 1015, 1215, 1415, 1615 mm (intermediate sizes: 216 1614 mm, in increments of 1 mm) Any combination of B Description Variants : Non-return damper, duct connection without flange holes -G: Non-return damper, duct connection with flange holes Parts and characteristics Casing Blades with low-friction bearings Blade restrictors Blade tip seals Bottom travel stop (angle section) Visible mullion from B = 997 mm Accessories Installation subframe: Installation subframe for the fast and simple installation of mechanically self-powered dampers Construction features Casing, material thickness 1.25 mm Blades, material thickness 1.0 mm Flanges on both sides, suitable for duct connection Additional side bar with fixing holes to accommodate the blade shafts and integral blade restrictors (pins) Blade restrictors prevent the blades from opening beyond a certain angle Materials and surfaces Casing, mullion and travel stop (angle section) made of galvanised sheet steel Blades made of formed aluminium Blade shafts made of brass Side bar made of PVC plastic Blade tip seals made of foamed polyester Blade restrictors made of plastic Maintenance Maintenance-free as construction and materials are not subject to wear Contamination should be removed as it may lead to corrosion and to increased closed blade air leakage PD 2

Function Functional description Non-return dampers open and close automatically. When the system is in operation, the blades open when air flows. When the system is shut down, the blades close due to their weight. They safely prevent air from flowing against the intended airflow direction. Schematic illustration of 1 2 6 5 3 4 1 Border 2 Blades (closed) 3 Mullion from B = 1000 mm 4 Blades (open) 5 Blade restrictor 6 Seal PD 3

Technical data Nominal sizes 200 215 to 1600 1615 mm Volume flow rate range 110 6460 l/s or 396 23256 m³/h at 2.5 m/s Total differential pressure 25 Pa at 2.5 m/s Maximum differential pressure in closing direction 100 Pa Operating temperature 20 to 80 C PD 4

Quick sizing Quick sizing tables provide a good overview of the volume flow rates with an airflow velocity of 2.5 m/ s. Intermediate values can be interpolated. UL, : Width 200 600 mm, volume flow rate at 2.5 m/s B [mm] 200 300 400 500 600 mm l/s m³/h l/s m³/h l/s m³/h l/s m³/h l/s m³/h 215 110 396 160 576 215 774 270 972 325 1170 315 160 576 235 846 315 1134 395 1422 475 1710 415 210 756 310 1116 415 1494 520 1872 625 2250 515 260 936 385 1386 515 1854 645 2322 775 2790 615 310 1116 460 1656 615 2214 770 2772 925 3330 715 360 1296 535 1926 715 2574 895 3222 1070 3852 815 410 1476 610 2196 815 2934 1020 3672 1220 4392 1015 510 1836 760 2736 1020 3672 1270 4572 1520 5472 1215 610 2196 910 3276 1220 4392 1520 5472 1820 6552 1415 710 2556 1060 3816 1420 5112 1770 6372 2120 7632 1615 810 2916 1210 4356 1620 5832 2020 7272 2420 8712 UL, : Width 800 1600 mm, volume flow rate at 2.5 m/s B [mm] 800 1000 1200 1400 1600 mm l/s m³/h l/s m³/h l/s m³/h l/s m³/h l/s m³/h 215 430 1548 540 1944 645 2322 755 2718 860 3096 315 630 2268 790 2844 945 3402 1100 3960 1260 4536 415 830 2988 1040 3744 1250 4500 1450 5220 1660 5976 515 1030 3708 1290 4644 1550 5580 1800 6480 2060 7416 615 1230 4428 1540 5544 1850 6660 2150 7740 2460 8856 715 1430 5148 1790 6444 2150 7740 2500 9000 2860 10296 815 1630 5868 2040 7344 2450 8820 2850 10260 3260 11736 1015 2030 7308 2540 9144 3050 10980 3550 12780 4060 14616 1215 2430 8748 3040 10944 3650 13140 4250 15300 4860 17496 1415 2830 10188 3540 12744 4250 15300 4950 17820 5660 20376 1615 3230 11628 4040 14544 4850 17460 5650 20340 6460 23256 Differential pressure v m/s 0.5 10 1 15 2 20 3 25 4 30 5 40 6 45 Δp t Pa PD 5

Specification text This specification text describes the general properties of the product. Texts for variants can be generated with our Easy Product Finder design programme. Rectangular non-return dampers to prevent air from flowing against the intended airflow direction; for installation into ductwork. Ready-to-install component which consists of a casing, blades with low-friction bearings, and travel stop and sealing parts. Special characteristics Any intermediate sizes within the standard size range are available operating temperature: 20 80 C Maximum differential pressure: 100 Pa Non-return dampers are opened and closed by the airflow; no actuator is required Non-return damper with formed aluminium blades for normal requirements; blades are fitted with seals for sound attenuation Materials and surfaces Casing, mullion and travel stop (angle section) made of galvanised sheet steel Blades made of formed aluminium Blade shafts made of brass Side bar made of PVC plastic Blade tip seals made of foamed polyester Blade restrictors made of plastic Technical data Nominal sizes: 200 215 to 1600 1615 mm Volume flow rate range: 110 6460 l/s or 396 23256 m³/h at 2.5 m/s Total differential pressure: 25 Pa at 2.5 m/s Maximum differential pressure in closing direction: 100 Pa Operating temperature: 20 to 80 C Sizing data [m³/h] Δp st [Pa] Air-regenerated noise L WA [db(a)] PD 6

Order code G / 800 1015 / ER / P1 RAL... Type Non-return damper Construction No entry: duct connection without flange holes G Duct connection, flange holes on both sides Nominal size [mm] B Installation subframe No entry: none ER With (only -G) Order example: G/600 1200 Construction Nominal size Installation subframe Surface Surface No entry: standard construction P1 Powder-coated, RAL CLASSIC colour PS Powder-coated, DB colour Gloss level RAL 9010 50 % RAL 9006 30 % All other RAL colours 70 % Duct connection, flange holes on both sides 600 1200 mm Without Standard construction PD 7

Dimensions and weight B: 200 1600 mm, intermediate sizes 201 1599 in increments of 1 mm : 215 1615 mm, intermediate sizes 216 1614 mm in increments of 1 mm The weight for the next larger size applies Flow cross section to calculate the airflow velocity A = B Unit of measure for B and : m + 76 100 38 B B + 76 10 10 120 : Weights mm B [mm] 200 300 400 500 600 800 1000 1200 1400 1600 215 2 3 3 4 4 5 6 8 10 11 315 2 3 4 4 5 6 7 9 10 11 415 3 4 4 5 6 7 8 10 11 13 515 3 4 5 6 6 7 9 11 12 15 615 4 5 5 6 7 8 10 12 13 17 715 4 5 6 7 8 8 11 13 15 18 815 5 6 6 8 9 9 13 16 17 19 1015 5 6 7 9 10 11 15 18 19 20 1215 6 7 7 10 11 13 17 20 20 22 1415 6 7 8 11 12 15 18 21 22 24 1615 7 8 8 11 13 17 19 22 24 26 kg PD 8

Product details Flange holes B + 76 B + 76 B X B X 1 + 76 2 + 76 X 22 38 Ø9.5 22 38 1 Even number of holes (hole pitch = 150 mm) 2 Uneven number of holes (hole pitch = 150 mm) : Width, no. of flange holes Width No. of holes mm 200 346 2 347 496 3 497 646 4 647 796 5 797 946 6 947 1096 7 1097 1246 8 1247 1396 9 1397 1546 10 1547 1600 11 n PD 9

Product details : eight, no. of flange holes eight No. of holes mm 215 362 2 363 512 3 513 662 4 663 812 5 813 962 6 963 1112 7 1113 1262 8 1263 1412 9 1413 1562 10 1563 1615 11 n PD 10

Installation details Installation and commissioning orizontal airflow: Vertical installation Vertical airflow: Installation into ducts with an upward airflow; horizontal installation Straight upstream section required (at least B + ) on the positive pressure side of fans Ensure a gradual start-up of fans to avoid a sudden pressure increase Only for installation in internal spaces For external walls the damper should be combined with a Type WG- external weather louvre Installation into an internal wall, without installation subframe 10 10 B 38 120 Duct installation B PD 11

Installation details Installation on the discharge side of a fan B > B + The airflow downstream of a fan is characterised by strong turbulence, and the velocity profile is not uniform. As a consequence, the blades of the non- return dampers are not uniformly subject to the airflow, and this may result in individual blades becoming subject to forces that might lead to mechanical damage. Safe operation requires a straight upstream section of at least B +. PD 12

Basic information and nomenclature Nomenclature L WA [db(a)] A-weighted sound power level of air-regenerated noise for the mechanically self-powered damper A [m²] Upstream cross section v [m/s] Airflow velocity based on the upstream cross section [m³/h] and [l/s] Volume flow rate Δp st [Pa] Static differential pressure Δp t [Pa] Total differential pressure All sound power levels are based on 1 pw. Principal dimensions B [mm] Duct width [mm] Duct height n [ ] Number of flange screw holes m [kg] Weight PD 13