EBARA Submersible Pumps DLU, DVU, DGUII, DGFU, DLFU, DVFU, DDLFU Technical Information Project Model: Chk d: Date: Contents

Similar documents
JDL SYSTEMS Submersible Sump / Sewage Pumps Table of Contents Project: Model: Chk d: Date:

Technical Data DML. Submersible Sewage Pumps with Single Channel Impeller. DML_Techdata_SS_V11 EBARA PUMPS AUSTRALIA PTY. LTD.

Contents Project: Model: Chk d: Date:

EBARA Submersible Propeller Pumps Contents Project: Model: Chk d: Date: Model

DSZ3. EBARA Submersible Propeller Pumps Contents Project: Model: Chk d: Date: Model

DSC3/DSCA3, DSZ3. EBARA Submersible Sewage and Propeller Pumps. Technical Data Contents Project: Model: Chk d: Date:

PUMP. Submersible Sewage Pumps Type DSC4 FEATURES/BENEFITS

WASTEWATER SUBMERSIBLE MOTOR PUMP MODEL DML3

Contents Project: Model: Chk d: Date:

MYERS 3MW VERTICAL DISCHARGE WASTEWATER PUMPS. Sewage, high-capacity sump, effluent

Submersible Stainless Steel Semi-Vortex Pumps Pumps

Ebara Submersible Sewage Pumps (Single Channel Impeller)

MYERS MODELS 4R AND 4RX

MYERS 4VCDP. 4" Solids Handling

MYERS MODELS 4RC AND 4RCX

CMLEU 80CMLEU622. EBARA Fluid Handling (803) (803) (fax) rev. 10/11

SUBMERSIBLE SEMI-VORTEX SEWAGE PUMPS

MYERS MODELS 4V AND 4VX

Built For Work. THREE-PHASE PUMPS

KW Submersible, Single-Vane Impeller

Selection Chart Project: Model: Chk d: Date: C C V V V A CAPACITY

MYERS MODELS 4VC & 4VCX

MYERS MODELS 6VC & 6VCX

DUMPER. Data Book 50 Hz

DUMPER. Data Book 50 Hz

DUMPER. Data Book 50 Hz

Series 8SHDU. Specifications: Series: 8SHDU 25-30HP, 1750RPM, 60Hz HP, 1150RPM, 60Hz. 21 Frame Driver 3.50" Spherical Solids Handling

Addendum No. 1. ITB for Lift Station # 6 Replacement Project Addendum Release Date August 03, 2017

EBARA CORPORATION. Technical Document. DSC4 50Hz Version 45 SHEETS. DOC. No. ETP-0002 REV. 1. Submersible Pump Development Dept.

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

Submersible Sump/Drainage Pump

Pump Specifications LE100-Series 1HP Submersible Sewage Pump

Series 6XSHD. Specifications: Series: 6XSHD 15-30HP, 1750RPM, 60Hz HP, 1150RPM, 60Hz. 21 Frame Driver 3" Spherical Solids Handling

GR NDER PUMPS. Technical Catalog

Series 6SHV. Specifications: Series: 6SHV 15-30HP, 1750RPM, 60Hz HP, 1150RPM, 60Hz. 21 Frame Driver 3" Spherical Solids Handling

CGUII/CGFU. Model CGUII/CGFU Contents. EBARA PRO Cast Grinder Pumps. Model 32CGUII61.5S

CENTERLINE DISCHARGE. Technical Data 5730 MV 490 FRAME PULL-UP SUBMERSIBLE,

GR NDER PUMPS. 505 Woodland Rd., Mt. Pocono, PA Phone: (570) Fax: (570)

- CONTENTS SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART IDROGO PERFORMANCE CHART IDROGO

NOTE: LEH100-Series high-head pumps require a minimum application of 15' head. Do not use pump in this area use a smaller pump.

KGX2-21. Grinder Pumps. 2HP Dual Seal Grinder Pump, External Start (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve

.2 Section Waste Management and Disposal..5 Section Thermometers and Pressure Gauges Piping Systems.

Technical Data 5430 M & W SUBMERSIBLE SOLIDS HANDLING PUMPS

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 203 PERFORMANCE CHART DW 204 PERFORMANCE CHART DW VOX 205

Pump Specifications LE40 Series 4/10 HP Submersible Sewage Pump Pump

SP A, SP. Submersible pumps Submersible motors Accessories. 50 Hz

MOTOR INSTALLATION. Knowledge of proper installation techniques is vital to the effective operation of a motor

Technical Data BEST 2~5. Stainless Steel Submersible Sump Pumps EBARA PUMPS AUSTRALIA PTY. LTD. Best 2-5_Techdata_SS_V10

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 201 CURVE SPECIFICATIONS 202 PERFORMANCE CHART IDROGO PERFORMANCE CHART IDROGO

Series 4XSHV. Specifications: Series: 4XSHV , 3450RPM, 60Hz 2-10HP, 1750RPM, 60Hz. 18 Frame Driver 3" Spherical Solids Handling

KG(X)3. Grinder Pumps. 3HP High Flow Grinder Pump (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve. Total Head (FT) Capacity (GPM)

P U M P. Pumps for Municipal and Commercial Operations

Pump Specifications. ELV Series Submersible Sump Pump with OilTector Control. ELV250 1/3 hp ELV280 1/2 hp ELV290 3/4 hp

Pump Specifications FL150 Series Submersible Effluent Pump

- DIMENSIONS AND WEIGHT 400 PUMP DUMPER 1X SERIES 400 PUMP DUMPER 2X SERIES 401 PUMP DUMPER 3X, 4X, 5X, 6X, 7X, 8X SERIES 402 PACKING 403

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 BEARINGS 301 MECHANICAL SEAL 301

XLE50 FLOW RATE (LPM) Flow Rate (GPM)

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 203 PERFORMANCE CURVE RIGHT PERFORMANCE CURVE RIGHT

Series 6SHM. Specifications: Series: 6SHM 15-30HP, 1750RPM, 60Hz HP, 1150RPM, 60Hz. 21 Frame Driver 3" Spherical Solids Handling

SPECIFICATIONS ULTIMAX SUB-SURFACE DIRECTIONAL AERATION SYSTEM

Series 4XSHM 18 Frame Driver 3" Spherical Solids Handling

- CONTENTS SPECIFICATIONS 200 SELECTION CHARTS 201 TYPE KEY 202 PERFORMANCE CHART DW 203 PERFORMANCE CHART DW VOX 204

Series 4XSHD. Specifications: Series: 4XSHD 3-10HP, 1750RPM, 60Hz. 18 Frame Driver 3" Spherical Solids Handling

Pump Specifications. D3648LSG, D3648LSGX Series Omnivore 2HP Duplex Grinder Packages LITERS PER SECOND

LITERS PER MINUTE TOTAL HEAD IN FEET TOTAL HEAD IN METERS GALLONS PER MINUTE

GD series Submersible Grinder Pump

XFL70 FLOW RATE (LPM) Flow Rate (GPM)

Dewatering Pump Type DUMPER

Submersible Vortex Sewage Pump

GRUNDFOS DATA BOOKLET SP A, SP. Submersible pumps, motors and accessories 50 Hz

C/C-CR. Submersible Sewage Pumps. Amenities from Technology for People and the Earth

SUBMERSIBLE GRINDER PUMPS: MOTORS: FLOWS to 135 USGPM HEADS to 350 FT TDH SEMI-OPEN, MULTI-VANE, IMPELLER DUPLEX STAINLESS STEEL GRINDING MECHANISM

Pump Specifications FL50 Series 1/2 hp Submersible Effluent Pump

INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR MODELS K4RP & K4VP SUBMERSIBLE SOLIDS-HANDLING SEWAGE PUMPS

Pump Specifications. Omnivore 2HP Submersible Grinder Pumps LSG200-SERIES (SINGLE STAGE) LSGX200-SERIES (TWO STAGE)

Pretest Module 21 Units 1-4 AC Generators & Three-Phase Motors

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEALS 303 DIAGRAM AND ELECTRIC CONNECTIONS 304

CSDA Best Practice. Hi-Cycle Concrete Cutting Equipment. Effective Date: Oct 1, 2010 Revised Date:

LITERS PER MINUTE GALLONS PER MINUTE

Page - SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART BEST ONE 202 PERFORMANCE CHART BEST ONE VOX 203

Installation & Operating Manual

SKV40. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 2" Solids: 2" GPM: TDH:

Pump Specifications FL100 Series Submersible Effluent Pump

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEAL 302

Pump Specifications 250 Series Submersible Sump / Effluent Pump

SPECIFICATIONS OXYMAX SUB-SURFACE AERATION SYSTEM

Pump Specifications. LE50 Series ½ HP Submersible Sewage Pump

Series 4SHM. Specifications: Series: 4SHM 3-10HP, 1750RPM, 60Hz. 18 Frame Driver 3" Spherical Solids Handling. Solids Handling Submersible Pumps

SUBMERSIBLE PUMP HSE RANGE

Page - CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING TECHNICAL DATA 500

200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY and CURVES SPECIFICATIONS 202 PERFORMANCE CURVES DW VOX 204

TOP MULTI. Submersible multi-stage pumps TOP MULTI 1 TOP MULTI 2-3. PERFORMANCE RANGE Flow rate up to 120 l/min (7.2 m³/h) Head up to 42 m

Pump Specifications 290 Series 3/4 hp Submersible Effluent Pump

A Series 50HZ. A - Series. Vertical Multistage Centrifugal in-line Pumps AVC/AVI/AVS ISO-9001

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

Pump Specifications 280 Series 1/2 hp Submersible Effluent Pump

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

SUBMERSIBLE SEWAGE AND EFFLUENT PUMPS

Transcription:

Project Model: Chk d: Date: Contents Section Page Material Specification 2-290 Impeller Design Data 2-29 Motor Protection DGUII, DLU, DVU Models 2-295 Thermal Protection DGFU, DLFU, DVFU, DDLFU Models 2-296 Leakage Detector DGFU, DLFU, DVFU, DDLFU Models 2-297 Cable Entry DGUII, DLU, DVU Models 2-298 Cable Entry DGFU, DLFU, DVFU, DDLFU Models 2-299 Paint Specifications 2-300 Mechanical Seal & Ball Bearing Data 2-30 Mechanical Seal Sectional DWG A-20, A-25, A-30 2-302 Mechanical Seal Sectional DWG A-40, A-45 2-303 Mechanical Seal Sectional DWG A-50 2-304 Mechanical Seal Sectional DWG A-60 2-305 Submergence 2-306 Capacitor Specification 2-307 QDC Lifting Chain 2-308 General Information 2-309 www.pumpsebara.com 2-289. (t) 803 327 5005 (f) 803 327 5097 rev. 0/02

Material Comparison Table MATERIALS JIS CODE ASTM, AISI CODE Cast Iron G550, FC20 ASTM A-48 Class 30 420 Stainless G4303, SUS429J AISI 420 304 Stainless Steel G4303, SUS304 AISI 304 Steel G30, SS4 ASTM A283 Grade D Brass H320, BSP3 ASTM B36 No. 272 www.pumpsebara.com 2-290 (t) 803 327 5005 (f) 803 327 5097 rev. 0/02

Impeller Data BACK P.O. MODEL TYPE DESIGN # VANES VANES 50DLU6.75 semi-open radial single yes 50DLU6.5 semi-open radial single yes 80DLU6.5 semi-open radial single yes 80DLMU6.5 semi-open radial single yes 80DLU62.2 semi-open radial 2 yes 80DLMU62.2 semi-open radial single yes 80DLU63.7 semi-open radial 2 yes 80DLMU63.7 semi-open radial 2 yes 00DLU6.5 semi-open radial 2 no 00DLU62.2 semi-open radial 2 no 00DLU63.7 semi-open radial 2 no 50DVU6.75 semi-open radial-recessed 8 yes 50DVU6.5 semi-open radial-recessed 8 yes 50DVU62.2 semi-open radial-recessed 8 yes 80DVU6.5 semi-open radial-recessed 8 yes 80DVCU62.2 semi-open radial-recessed 8 yes 80DVBU62.2 semi-open radial-recessed 8 yes 80DVBU63.7 semi-open radial-recessed 8 yes 80DVCU63.7 semi-open radial-recessed 8 yes 00DVU63.7 semi-open radial-recessed 8 yes 32DGUII6.5 semi-open radial-recessed 0 yes 32DGFU6.5 semi-open radial-recessed 0 yes 50DGFU62.2 semi-open radial-recessed 0 yes 50DGFU63.7 semi-open radial-recessed 0 yes 50DLFU6.5 semi-open radial single yes 80DLFU6.5 semi-open radial single yes 80DLMFU6.5 semi-open radial single yes 80DLFU62.2 semi-open radial 2 yes 80DLFMU62.2 semi-open radial single yes 80DLFU63.7 semi-open radial 2 yes 80DLMFU63.7 semi-open radial 2 yes 80DLFU65.5 semi-open mixed flow 2 yes 80DLMFU65.5 semi-open mixed flow 2 yes 80DLFU67.5 semi-open mixed flow 2 yes 80DLCMFU 67.5 semi-open mixed flow 2 yes 80DLF6 semi-open mixed flow 2 yes 80DLCMFU6 semi-open mixed flow 2 yes www.pumpsebara.com 2-29 (t) 803 327 5005 (f) 803 327 5097 rev. 0/

Impeller Data BACK P.O. MODEL TYPE DESIGN # VANES VANES 80DLFU65 semi-open mixed flow 2 yes 80DLFU68 semi-open mixed flow 2 yes 80DLFU622 semi-open mixed flow 2 yes 00DLFU6.5 semi-open radial 2 no 00DLFU62.2 semi-open radial 2 no 00DLFU63.7 semi-open radial 2 no 00DLFU65.5 semi-open mixed flow 2 yes 00DLMFU65.5 semi-open mixed flow 2 yes 00DLFU67.5 semi-open mixed flow 2 yes 00DLFU6 semi-open mixed flow 2 yes 00DLFU65 semi-open mixed flow 2 yes 00DLFU68 semi-open mixed flow 2 yes 00DLFU622 semi-open mixed flow 2 yes 00DLFU630 enclosed radial 2 yes 00DLFU637 enclosed radial 2 yes 00DLFU645 enclosed radial 2 yes 50DLFU67.5 semi-open mixed flow 2 yes 50DLFU6 semi-open mixed flow 2 yes 50DLFU65 semi-open mixed flow 2 yes 50DLFU68 semi-open mixed flow 2 yes 50DLFU622 semi-open mixed flow 2 yes 50DLFU630 enclosed mixed flow 2 yes 50DLFU637 enclosed mixed flow 2 yes 50DLFU645 enclosed mixed flow 2 yes 200DLFU67.5 semi-open mixed flow 2 yes 200DLFU6 semi-open mixed flow 2 yes 200DLFU65 semi-open mixed flow 2 yes 200DLFU68 semi-open mixed flow 2 yes 200DLFU622 semi-open mixed flow 2 yes 200DLFU630 enclosed mixed flow 2 yes 200DLFU637 enclosed mixed flow 2 yes 200DLFU645 enclosed mixed flow 2 yes 250DLFU6 semi-open mixed flow 2 yes 250DLFU65 semi-open mixed flow 2 yes 250DLFU68 semi-open mixed flow 2 yes 250DLFU622 semi-open mixed flow 2 yes 250DLFU630 enclosed mixed flow 2 yes 250DLFU637 enclosed mixed flow 2 yes 250DLFU645 enclosed mixed flow 2 yes 300DLFU68 semi-open mixed flow 2 yes 300DLFU622 semi-open mixed flow 2 yes www.pumpsebara.com 2-292 (t) 803 327 5005 (f) 803 327 5097 rev. 0/

Impeller Data BACK P.O. MODEL TYPE DESIGN # VANES VANES 300DLFU630 enclosed mixed flow 2 yes 300DLFU637 enclosed mixed flow 2 yes 300DLFU645 enclosed mixed flow 2 yes 50DVF6.5 semi-open radial-recessed 8 yes 50DVF62.2 semi-open radial-recessed 8 yes 80DVF6.5 semi-open radial-recessed 8 yes 80DVBF62.2 semi-open radial-recessed 8 yes 80DVCF62.2 semi-open radial-recessed 8 yes 80DVBF63.7 semi-open radial-recessed 8 yes 80DVCF63.7 semi-open radial-recessed 8 yes 80DVF65.5 semi-open radial-recessed 8 yes 80DVF67.5 semi-open radial-recessed 8 yes 80DVBF6 semi-open radial-recessed 8 yes 80DVCF6 semi-open radial-recessed 8 yes 80DVCF65 semi-open radial-recessed 8 yes 80DVCF68 semi-open radial-recessed 8 yes 80DVCF622 semi-open radial-recessed 8 yes 00DVF63.7 semi-open radial-recessed 8 yes 00DVF65.5 semi-open radial-recessed 8 yes 00DVF67.5 semi-open radial-recessed 8 yes 00DVBF6 semi-open radial-recessed 8 yes 00DVCF6 semi-open radial-recessed 8 yes 00DVDF6 semi-open radial-recessed 8 yes 00DVCF65 semi-open radial-recessed 8 yes 00DVDF65 semi-open radial-recessed 8 yes 00DVDF68 semi-open radial-recessed 8 yes 00DVDF622 semi-open radial-recessed 8 yes 50DVBF6 semi-open radial-recessed 8 yes 50DVBF65 semi-open radial-recessed 8 yes 50DVBF68 semi-open radial-recessed 8 yes 50DVCF68 semi-open radial-recessed 8 yes 50DVBF622 semi-open radial-recessed 8 yes 50DVCF622 semi-open radial-recessed 8 yes 00 80DDLFU6 semi-open mixed flow 2 yes 00 80DDLFU65 semi-open mixed flow 2 yes 00 80DDLFU68 semi-open mixed flow 2 yes 00 80DDLFU622 semi-open mixed flow 2 yes 50 00DDLFU6 semi-open mixed flow 2 yes www.pumpsebara.com 2-293 (t) 803 327 5005 (f) 803 327 5097 rev. 0/

Impeller Data BACK P.O. MODEL TYPE DESIGN # VANES VANES 50 00DDLFU65 semi-open mixed flow 2 yes 50 00DDLFU68 semi-open mixed flow 2 yes 50 00DDLFU622 semi-open mixed flow 2 yes 50 00DDLFU630 enclosed radial 2 yes 50 00DDLFU637 enclosed radial 2 yes 50 00DDLFU645 enclosed radial 2 yes 200 50DDLFU6 semi-open mixed flow 2 yes 200 50DDLFU65 semi-open mixed flow 2 yes 200 50DDLFU68 semi-open mixed flow 2 yes 200 50DDLFU622 semi-open mixed flow 2 yes 200 50DDLFU630 enclosed mixed flow 2 yes 200 50DDLFU637 enclosed mixed flow 2 yes 200 50DDLFU645 enclosed mixed flow 2 yes 200 50DDLFU630 enclosed mixed flow 2 yes 200 50DDLFU637 enclosed mixed flow 2 yes 200 50DDLFU645 enclosed mixed flow 2 yes 200 200DDLFU630 enclosed mixed flow 2 yes 200 200DDLFU637 enclosed mixed flow 2 yes 200 200DDLFU645 enclosed mixed flow 2 yes 250 250DDLFU630 enclosed mixed flow 2 yes 250 250DDLFU637 enclosed mixed flow 2 yes 250 250DDLFU645 enclosed mixed flow 2 yes 300 300DDLFU630 enclosed mixed flow 2 yes 300 300DDLFU637 enclosed mixed flow 2 yes 300 300DDLFU645 enclosed mixed flow 2 yes www.pumpsebara.com 2-294 (t) 803 327 5005 (f) 803 327 5097 rev. 0/

Motor Protection (Auto-Cut). MODELS DLU, DVU, DGUII 2. CONSTRUCTION AND PRINCIPLES OF OPERATION There are two different types of Auto-Cuts. One is a single pole model that is used for single phase motors and the other is a three pole model that is used for three phase motors. Figure below illustrates the construction and operation of the three phase model. Composition: 3 sets of contacts, Snap-Acting Disk, 3 Heaters, 3 Terminals and Calibration bolt and nut. The above parts are encased in a Bakalite housing. FIGURE The Auto-Cut is installed directly over the winding of the motor, where it not only senses overheating of the winding but also excess amperage draw by each of the three windings. Figure 2 shows the Auto-Cut in its normal operating condition (Contacts closed). When actuating temperature is reached, the Snap-Acting Disk snaps open to interrupt the circuits as shown in figure 3. When the motor temperature cools down to the safe operating temperature, the Snap-Acting Disk resets automatically to the original position as shown in figure 2, and the motor restarts. FIGURE 2 FIGURE 3 3. PROVIDES PROTECTION FROM ThE FOLLOwING: Single Phasing Low Voltage Phase Imbalance Locked Rotor Run Dry All of the above conditions will cause the motor protector to actuate. www.pumpsebara.com 2-295 (t) 803 327 5005 (f) 803 327 5097 rev. 0/02

Thermal Protection The motor shall be equipped with a protector such as automatic cut-off device and thermal protector. The motors described below shall incorporate Miniature Thermal Protectors (MTP) which are embedded in the windings. When temperature of the winding raises and reaches the MTP acting point, the motor protection circuit is activated to protect motor from over heat.. Applicable model Model: DGFU, DLFU, DVFU, DDLFU 2. MTP Specifications: Model Type of Contact Acting Temperature Re-setting Temperature Capacity of Contact KLIXON 9700K-66-25 b (Normally-Closed contact Acting-open) 40±5 C (284±9 F) 85±0 C (85±8 F) Voltage (V) DC 24 AC 5 AC 230 Amperage (A) 8 8 3 AC 460 5.5 3. Installation: MTP shall be embedded in the stator windings as shown at right 4. Construction: Construction of the MTP is as shown below: www.pumpsebara.com 2-296 (t) 803 327 5005 (f) 803 327 5097 rev. 0/0

Details of Leakage Detector. Applicable model Model: DGFU, DLFU, DVFU, DDLFU 2. Construction: Each switch has a magnet-containing float which senses the liquid level and magnetically actuates a dry reed switch encapsulated within a stem. The switch opens on rise of liquid. 3. Specifications Apply to 2 to 30HP Lead Wire Breaking Capacity : AC50VA, DC50W Max. Breaking Current : AC0.5A, DC0.5A Float Body (Polypropylene) Open Max. Operating Voltage : AC300V, DC300V Float (Polypropylene) Stopper (36 S.S.) Close 2. Apply to 40 to 60HP Lead Wire Breaking Capacity : AC2VA, DC0W Max. Breaking Current : AC0.6A, DC0.5A Max. Operating Voltage : AC200V, DC200V Float Body (304 S.S.) Open Float (304 S.S.) Stopper (304 S.S.) Close www.pumpsebara.com 2-297 (t) 803 327 5005 (f) 803 327 5097 rev. 05/5

EBARA Submersible Pumps DLU, DVU, DGUII, DGFU, DLFU, DVFU, DDLFU Details of Cable Entry ( of 2) Applicable to Models DGUII, DLU, DVU 2 3 4 Water cannot leak into motor even if the cable is cut or damaged because cable leads are soldered and then isolated by rubber sealing, thus preventing any capillary action past that point. Thick moulded shoulders bolted to motor dome provide exceptional strength and form a strong compression seal. Cable resists bending forces by increased cable diameter. A Strain Relief Chain or Strain Relief Gland protects cable entry from pulling. /2 to 5HP www.pumpsebara.com 2-298 (t) 803 327 5005 (f) 803 327 5097 rev. 0/02

EBARA Submersible Pumps DLU, DVU, DGUII, DGFU, DLFU, DVFU, DDLFU Details of Cable Entry (2 of 2) Applicable to Models DLFU, DVFU, DDLFU, DGFU Based on their first years of experience, EBARA now provides the most dependable cable entry construction of any submersible pump. Its features are as follows: Line Cord Packing Washer (304 S.S.) O-Ring Motor Cover Cord Housing A Bolt Sealing Compound DETAIL A Connecting Sleeve Sealing Compound Sealing Metal Heat Shrinkable Tube www.pumpsebara.com 2-299 (t) 803 327 5005 (f) 803 327 5097 rev. 0/02

Shop Painting Standards. Scope This specification covers the methods for painting the following EBARA PUMPS in the shop. EBARA Models: DGUII, DLU, DVU, DGFU, DLFU, DVFU, DDLFU 2. Surface Preparation All surfaces to be painted shall be cleaned of oil, grease or other similar materials with solvent, and then shall be brushed and air blasted to remove rust or scale. Prior to above preparation, mill scale, rust scale, chips and other foreign materials shall be removed in accordance with painting schedule. 3. Coating Procedure Detailed coating procedures are as shown in each paint schedule. Service External Surface Coats st 2nd Final color: Black Surface Preparation Type of Paint Zinc-chromate primer Coal Tar Epoxy Painting Schedule SPPC-VISI-SP-3-63 Brand name Maker TAIYO PAInT ZT-PRIMER CO., LTD.CO., LTD. Hi-Build Tneme-Tar TnEMEC CO., InC. 46-43 Service Internal Surface Coats st Surface Preparation Type of Paint Zinc-chromate primer Painting Schedule SPPC-VISI-SP-3-63 Brand name Maker TAIYO PAInT ZT-PRIMER CO., LTD. www.pumpsebara.com 2-300 (t) 803 327 5005 (f) 803 327 5097 rev. 02/09

Mechanical Seal and Ball Bearing Data DGUII DGFU MODEL HP 2 3 5 OUTPUT kw.5 2.2 3.7 MECHAnICAL SEAL TYPE A-20 A-30 A-30 LUBRICATInG OIL CAPACITY name OZS 4 43 43 CC 000 200 200 TURBInE OIL SAE 0W or 20W (TURBInE OIL #32) BALL BEARInG BOTTOM 6306ZZDR 6308ZZDR 6308ZZDR TOP 6304ZZ 6304ZZ 6304ZZ DLU DLMU DVU DLFU DLMFU DVFU DDLFU MODEL HP 2 3 5 7 /2 0 5 20 25 30 40 50 50 60 60 OUTPUT kw 0.75.5 2.2 3.7 5.5 7.5 5 8.5 22 30 37 37 45 45 Apply to 00DLFU and 50 00DDLFU only MECHAnICAL SEAL TYPE A-20 A-25 A-30 A-30 A-40 A-40 A-40 A-45 A-45 A-45 A-45 A-50 A-60 A-50 A-60 LUBRICATInG OIL CAPACITY name OZS 30 40 50 50 90 90 20 20 20 20 220 240 240 240 240 CC 630 930 380 380 2500 2500 3500 6200 6200 6200 6500 7000 7000 7000 7000 TURBInE OIL SAE 0W or 20W (TURBInE OIL #32) BALL BEARInG BOTTOM 6205ZZ 6306ZZ 6307ZZ 6308ZZ 6309ZZ 6309ZZ 633ZZ 635ZZ 635ZZ 635ZZ 534ZZDR 535ZZDR 535ZZDR 535ZZDR 535ZZDR TOP 6203ZZ 6204ZZ 6205ZZ 6205ZZ 6306ZZ 6306ZZ 6308ZZ 6308ZZ 6309ZZ 6309ZZ 6309ZZ 630ZZ 630ZZ 630ZZ 630ZZ www.pumpsebara.com 2-30 (t) 803 327 5005 (f) 803 327 5097 rev. 0/02

Mechanical Seal Sectional View DOUBLE MECHANICAL SEALS with HARD seal face materials are provided on all EBARA D Series submersible pumps. The double mechanical seal in oil chamber provides long life and friction-free sealing of the motor shaft. Typical construction and materials are as follows: TYPE A-20, A-25, A-30 DGUII, 2hP DGFU, 2 to 5hP DLU, to 5hP DVU, to 5hP DLFU, 2 to 5hP DVFU, 2 to 5hP no. PART name PART name no. FOR SET Packing n.b.r. 2 Floating Ceramic 3 Seal Ring Carbon Graphite 4 Spring 304 SS 5 Seal Ring Silicon Carbide 6 Floating Ring Silicon Carbide 7 Packing n.b.r. www.pumpsebara.com 2-302 (t) 803 327 5005 (f) 803 327 5097 rev. 0/02

Mechanical Seal Sectional View DOUBLE MECHANICAL SEALS in a tandem arrangement with HARD seal face materials are provided on all EBARA D-Series submersible pumps. The double mechanical seal in oil chamber provides long life and friction-free sealing of the motor shaft. Typical construction and materials are as follows: TYPE A-40, A-45 DLFU, 7 /2 to 40hP DVFU, 7 /2 to 30hP DDLFU, 5 to 40hP no. PART name MATERIALS no. FOR SET Packing n.b.r. 2 Seal Ring Carbon Graphite 3 Floating Ring Ceramic 4 Snap Ring Spring Steel 5 Snap Ring Spring Steel 6 Floating Ring Silicon Carbide 7 Seal Ring Silicon Carbide 8 Shock Absorbing Rubber Fluorine Rubber 9 Spring 0 Spring Retainer www.pumpsebara.com 2-303 (t) 803 327 5005 (f) 803 327 5097 rev. 0/02

EBARA Submersible Pumps DLU, DVU, DGUII, DGFU, DLFU, DVFU, DDLFU Mechanical Seal Sectional View DOUBLE MECHANICAL SEALS in a tandem arrangement with HARD seal face materials are provided on all EBARA D-Series submersible pumps. The double mechanical seal in oil chamber provides long life and friction-free sealing of the motor shaft. Typical construction and materials are as follows: TYPE A-50 DLFU, 50 to 60hP DDLFU, 50 to 60hP Except 00DLFU & 50 00DDLFU no. PART name MATERIALS no. FOR SET 2 3 4 5 6 7 8 9 O-Ring Floating Ring Seal Ring Bellows Spring Spring Retainer Snap Ring Snap Ring O-Ring n.b.r. /Ceramic Carbon Graphite n.b.r. Spring Steel Spring Steel n.b.r. 0 Floating Ring Tungsten Carbide Seal Ring Tungsten Carbide 2 3 4 Shock Absorbing Rubber Spring Spring Retainer Fluorine Rubber www.pumpsebara.com 2-304 (t) 803 327 5005 (f) 803 327 5097 rev. 0/02

EBARA Submersible Pumps DLU, DVU, DGUII, DGFU, DLFU, DVFU, DDLFU Mechanical Seal Sectional View DOUBLE MECHANICAL SEALS in a tandem arrangement with HARD seal face materials are provided on all EBARA D-Series submersible pumps. The double mechanical seal in oil chamber provides long life and friction-free sealing of the motor shaft. Typical construction and materials are as follows: TYPE A-60 DLFU, 50 to 60hP DDLFU, 50 to 60hP 00DLFU & 50 00DDLFU ONLY no. PART name MATERIALS no. FOR SET 2 3 4 5 6 7 8 9 0 2 3 4 5 6 7 8 9 Parallel Pin O-Ring Stationary Ring Rotating Ring Bellows Case Case Drive Ring Spring Spring Retainer Packing Rotating Ring Stationary Ring Bellows Case Case Drive Ring Spring Spring Retainer 36S.S. n.b.r. Silicon Carbide Silicon Carbide n.b.r. n.b.r. Carbon Graphite Ceramic n.b.r. www.pumpsebara.com 2-305 (t) 803 327 5005 (f) 803 327 5097 rev. 0/02

EBARA Submersible Pumps DLU, DVU, DGUII, DGFU, DLFU, DVFU, DDLFU Maximum Submergence of Pumps EBARA submersible pumps shall be capable of continuous submergence under water without loss of watertight integrity to the following depths: 65 ft. www.pumpsebara.com 2-306 (t) 803 327 5005 (f) 803 327 5097 rev. 0/02

Start and Operating Capacitor Specification Model DGUII Model 32DGUII6.5S Capacity 6~93µF Start Capacitor Voltage Temp. 4~+59 F Capacity 25µF Operating Capacitor Voltage Temp. 3~+56 F Model DGFU Model 32DGFU6.5S 50DGFU62.2S 50DGFU63.7S Capacity 6~93µF 270~324µF 26~259µF Start Capacitor Voltage Temp. 4~+59 F 4~+59 F 4~+59 F Capacity 25µF 35µF 55µF Operating Capacitor Voltage Temp. 3~+56 F 3~+56 F 3~+56 F Model DLU/DLMU Model 50DLU67.5S Capacity 40µF Start Capacitor Voltage Temp. 4~+59 F Capacity 20µF Operating Capacitor Voltage Temp. 3~+56 F 050DLU6.5S 080 DLU6.5S 00DLU6.5S 00µF 4~+59 F 30µF 3~+56 F 00 080 DLU62.2S 00 080 DLU63.7S 80DLMU6.5S 80DLMU62.2S 80DLMU63.7S 200µF 400µF 00µF 200µF 400µF 4~+59 F 4~+59 F 4~+59 F 4~+59 F 4~+59 F 35µF 40µF 30µF 35µF 40µF 3~+56 F 3~+56 F 3~+56 F 3~+56 F 3~+56 F Model DVU Model 50DVU6.75S 050 080DVU6.5S 050DVU 080DVCU62.2S 080DVBU 080DVCU 080DVBU63.7S 00DVU Capacity 40µF 00µF 200µF 400µF Start Capacitor Voltage Temp. 4~+59 F 4~+59 F 4~+59 F 4~+59 F Capacity 20µF 30µF 35µF 40µF Operating Capacitor Voltage Temp. 3~+56 F 3~+56 F 3~+56 F 3~+56 F www.pumpsebara.com 2-307 (t) 803 327 5005 (f) 803 327 5097 rev. 0/02

Application of QDC s Lifting Chain QDC MODEL LM50 LM65 LM80 LL65 LL80 LL00 LL25 LL50 LL250U LL300U LL50YU LL200YU LL250YU LL300YU LME50 LME65 LME80 LLE65 LLE80 LLE00 LLE25 LLE50 LLE250U LLE300U LIFTInG CHAIn MODEL MATERIAL : GALVAnIZED STEEL MATERIAL : STAInLESS LCM-6 LCMS-6 LCL-9 LCLS-9 LCM-6 LCMS-6 LCL-9 LCLS-9 STAnDARD LEnGTHS = 20 FEET www.pumpsebara.com 2-308 (t) 803 327 5005 (f) 803 327 5097 rev. 0/02

Lifting chain Lifting Chain The Ebara lifting chain is high tensile strength galvanized steel or stainless steel. Model Size Material Max. Load Wt. (mm) (lbs.) (lbs.) LCM-6 6 galvanized 200 2 LCMS-6 6 stainless 200 2 LCL-9 9 galvanized 2400 24 LCLS-9 9 stainless 2400 24 To Attach Chain:. Unbolt Pump bail 2. Slide open end ring over bail 3. Re-bolt bail to pump top. For chain lengths longer than 20 ft.: - use quick links or shackles to join 20 ft. lengths. www.pumpsebara.com 2-308. (t) 803 327 5005 (f) 803 327 5097 rev. /02

Vortex Pumps Model DVU, DVFU. PRINCIPLES OF VORTEx PUMP When the vortex impeller rotates in the casing, it generates primary vortex (B) and secondary vortex (A) as shown in the drawing, and then pumps up water: 2. FEATURES a) As there is a large space between the impeller and the suction cover and there are no obstacles in the water passage, almost all sewage can be discharged without clogging. 2. b) EBARA s unique hydraulic design of impeller and casing provide highly efficient performance which compares favorably with ordinary non-clog pump in spite of the large space. www.pumpsebara.com 2-309 (t) 803 327 5005 (f) 803 327 5097 rev. 0/02

EBARA Submersible Pumps DLU, DVU, DGUII, DGFU, DLFU, DVFU, DDLFU Clogging Phenomena and Prevention From abundant experience, EBARA placed the following design concepts on sump and sewage pumps in order to prevent clogging.. Strainer Inlet CLOGGING PhENOMENA AT: PREVENTION Choose a pump with a large strainer opening or pump without strainer. 2. Impeller Inlet Shape inlet portion of the impeller blade as described below. The inlet edge of the impeller vanes are angled toward the impeller periphery so as to facilitate the release of objects that might otherwise clog the pump. 3. Clearance between Impeller and Suction Cover Increase clearance Model DVU, DVFU. 4. Casing Tongue Provide large radius on tongue, or cut water. 5. Shaft End Eliminate sharp points on impeller and impeller nut (use rounded impeller nut). www.pumpsebara.com 2-30 (t) 803 327 5005 (f) 803 327 5097 rev. 0/02

Understanding Unbalance ( of 5) Three phase motors can be damaged by sustained application of unbalanced voltages. This problem can easily be more severe than application of balanced voltages above or below normal data plate ratings. UNbALANCED PhASES Unbalanced voltages applied to a 3 phase motor will adversely affect the motor operating characteristics. Motors will operate successfully where the variation in the supply voltage does not exceed plus or minus 0% of the name plate rating, but the voltages of a given 3 phase circuit should be evenly balanced as closely as can be read on the usually available commercial voltmeter. A relatively small unbalance in voltage will cause a considerable increase in temperature rise. For example, a 3.5% voltage unbalance will cause approximately 25% increase in temperature rise. The full load speed is reduced slightly when the motor operates on unbalanced voltages. An unbalanced voltage will cause unequal currents to flow in the windings. If the motor is moderately or heavily loaded, currents in certain coils will exceed rating and overheat. Thermal cut-outs buried in the windings may detect this overheating and shut down the motor. If not, winding failure will result due to insulation damage. A second type of damage is caused by rotor heating. This can occur without excessive coil current on a lightly loaded motor. Damaging currents at these frequencies will flow as a result of voltage unbalance. Rotors are not designed for such currents, especially those of recent design optimized by computer techniques. Rotor overheating is most likely to cause bearing or seal failure, again perhaps, after a long period of time. Thermal cut-outs in the stator seldom will detect this problem and starter failures have been charged to mechanical failure while the cause was actually voltage unbalance. UNbALANCED CURRENTS Questions relative to how much unbalance a motor can tolerate have been raised from time to time. This condition is generally due to voltage unbalance in the supply and can usually be corrected by working with the power company involved. The effect of unbalanced phase currents is to increase the heating of the motor, thus reducing its efficiency. It might be said that unbalanced currents, as far as motor temperature rise is concerned, acts like additional load on the motor. For this reason the permissible loading decreases with increasing unbalance of phase currents. Before a problem of this nature can be corrected, it is necessary to determine whether the source is with the submersible motor or with the electrical supply furnished for its operation. The following facts will assist in locating the source of the problem and will govern the steps to be taken in its correction. Unbalanced amperage is generally caused by problems in either of the following areas: A. External power supply, including the pump control box. B. Internal problem with motor windings or stator leads to drop cable connection. The following diagrams and explanation will present you with a method by which you can localize the problem as being caused by A or by B. In other words, we are trying to find out whether the trouble lies in the area from the control back through the supply or whether it is a result of malfunction beyond the control down to and including the pump motor. www.pumpsebara.com 2-3 (t) 803 327 5005 (f) 803 327 5097 rev. 0/02

Understanding Unbalance (2 of 5) Assuming that the unit is connected to the supply so that the 3 phase motor is running in the correct direction of rotation, there are two other combinations of connection that will change phase connections but not change the rotation. This is accomplished by changing the position of all three drop cable leads at their termination in the control. It is important that all three leads be interchanged each time as the interchanging of only two leads will result in reversing the motor. If any two pump cable power leads are interchanged in the control it will change the rotation of the motor. If all three leads are interchanged in the control, the pump will continue to operate in the original rotation. Once the three power leads in the pump cable are connected to the terminals in the control so that the pump is operating in the correct direction of rotation, there are two other possible combinations that will also operate the pump in the correct direction. ExAMPLE Assuming that combination # is operating in correct rotation the 2nd and 3rd combination will also operate in the correct rotation. If combination # shows unbalanced amperage readings, it is sometimes possible that one of the other two combinations above will operate at a lesser degree of unbalance. Combination st 2nd 3rd T Red Black White T2 Black White Red T3 White Red Black If the unbalanced leg follows the same wire in the drop cable from the pump, regardless of which position it is connected to on the control terminals the fault would most likely be found in the stator windings or in the stator leads to drop cable connections. If the unbalanced leg remains related to the same terminal in the control box regardless of which wire is connected to it, the fault would most likely be found in the power supply or possibly poor connection in the control. www.pumpsebara.com 2-32 (t) 803 327 5005 (f) 803 327 5097 rev. 0/02

Understanding Unbalance (3 of 5) GENERAL CAUSES OF UNbALANCE. Extreme case as in Single Phasing of a 3 phase supply. The source may be in the control. Either a blown fuse, defective or poor contact point in contactor or any interruption in wiring or terminals. 2. Pulling single phase loads from the 3 phase supply in an unbalanced sequence. This can be especially true in a job shop where electrical load is unpredictable at any given time. As we are speaking of Voltage and Amperage in terms of percentage of Unbalance, the question arises as to how to figure the % of unbalance in a three phase system. The formula reads as follows: Maximum Deviation from average 00 = Percentage of Unbalance Average of the 3 readings ExAMPLE L L2 = 234V Average of the 3 readings: 229V L L3 = 230V Maximum deviation from the average: 229 223=6V L2 L3 = 223V Voltage unbalance : 6/229 x 00 = 2.62% L = 63.3 amps Average of the 3 readings: 6. amps L2 = 65.6 amps Maximum deviation from the average: 6. 54.4=6.7 amps L3 = 54.4 amps Amperage unbalance: 6.7/6. x 00 = 0.97% Maximum permissible % of amperage unbalance allowed at motor full load is 5%. Permissible % of unbalance increases as motor load decreases. However, unless under specific conditions, the motor should, for safety, be considered to be operating at full load. Maximum permissible % of Voltage unbalance allowed is %. Keep in mind that, especially with Delta wound motors, the true amperage unbalance is in the neighborhood of 6 to 0 times the voltage unbalance. The true amperage unbalance is not readily determined by the amperage readings taken in the supply lines. Excess circulating currents within the stator not recorded on your amp meter contribute to overheating of winding insulation. The maximum percentages mentioned above are based on motors working at full load. Slightly higher maximums may be allowed at less than full load conditions but good practice and full warranty must necessarily be based on full load conditions especially with squirrel cage induction motors assigned to such variable conditions as is found in the pumping of liquids, etc. www.pumpsebara.com 2-33 (t) 803 327 5005 (f) 803 327 5097 rev. 0/02

Understanding Unbalance (4 of 5) ExPLANATION OF NEMA STANDARD MGI-973-SECTION 4.34 This standard presents guidelines on Voltage Unbalance. While the voltages should be evenly balanced as closely as can be read on the usually available commercial voltmeter, it is recommended that any voltage unbalance at the Motor Terminals not exceed %. Unbalanced Voltage can be broken into two opposing components, a positive sequence voltage and negative sequence voltage component. The positive sequence, operating the motor in its correct rotation, is opposed by the negative sequence, causing a build up of heat. Unbalance causes extra motor losses and in turn heating of the Rotor and Windings. Increased motor losses increase power costs. Line currents, as a result of unbalanced voltage, will be greatly unbalanced in the order of 6 to 0 times the voltage unbalance. This true value of the current unbalance will not be apparent on a normal reading, as part of the unbalance is in the form of circulating currents in the motor and does not show up in the line. It is recommended that any amperage unbalance at the motor terminals not exceed 5%. In the phase with the highest current, the percentage increase in temperature rise will be approximately two times the square of the percentage of voltage unbalance. ExAMPLE If voltage unbalance was 3%, percentage increase in temperature rise would be: 2 (3%) 2 = 2 9% = 8% www.pumpsebara.com 2-34 (t) 803 327 5005 (f) 803 327 5097 rev. 0/02

Understanding Unbalance (5 of 5) Any significant voltage unbalance notably reduces the margins that motors have at usual service conditions, i.e. Service Factor. Voltage Unbalance can be more harmful than short time overloading or moderate low voltage conditions. NOTE If the unbalance condition cannot be corrected, it would then be advisable to reduce the motor load or oversize the motor. EFFECT OF VOLTAGE VARIATION ON INDUCTION MOTOR ChARACTERISTICS www.pumpsebara.com 2-35 (t) 803 327 5005 (f) 803 327 5097 rev. 0/02