Lumination TM LED Luminaires LAL Series - Continuous Run Option

Similar documents
Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

Lumination TM LED Luminaires Suspended LED Fixture (Series EP14)

Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame

Tetra minimax. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide

WARNING/AVERTISSEMENT. Coupez l alimentation électrique à la boîte de fusibles ou au disjoncteur avant servicing or installing product.

Horticulture Batten LED Luminaire

Wet Rated Batten LED Luminaire

Lumination TM LED Luminaire (IS Series)

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

Lumination TM LED Luminaire LUR Series

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

WARNING / AVERTISSEMENT

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

MOONRING 1.5 MOONRING 3

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

ELV1abbccd-e. Color Temperature: 30 = 3000K White 35 = 3500K White 40 = 4000K White 45 = 4500K White 50 = 5000K White

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing

OSQ Series IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Area Light TO INSTALL:

LED Utility Wrap Fixture

Enclosure for AMP1 Series Energy Meters with Swing Panel Kit

LED Recessed Troffer Retrofit Kit

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

LS1 SERIES IMPORTANT: READ ALL INSTRUCTIONS THOROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF LINEAR SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE.

poollux Power plx-pw60 & plx-pw100

INSTALLATION INSTRUCTION Oculux 3.5" Architectural Downlight R3CRN-11, R3CSN-11

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight

User s Manual ATTILA THE ANKYLOSAURUS TM VTech Printed in China US

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Installation Instructions: Read these instructions in its entirety before performing any installation work.

HBDBM High Bay Series

Learn & Discover Driver TM

FLO Home TM G5 Model. Installation guide

Bear s Baby Laptop TM

User s Manual HORNS THE TRICERATOPS TM VTech Printed in China US

V-D2425 and V-D2440 Digital Clock

Installation Instructions: Read these instructions in its entirety before performing any installation work.

Sentinel Field Satellite Controller

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed

INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1107

F261 Series Fluid Flow Switches

User s Manual VTech Printed In China US CA Manual new.indd /6/6 10:41:57

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit

INSTALLATION INSTRUCTIONS

Elle Surface Mounting Instructions

Lumination LED Luminaires LED Downlight Architectural Series DI6R - 6 Round Aperture

Installation Instructions 4 Gravity Enhanced Color Adjustable

VR44-MU-xxx-8yy-xxxxA

Powerware Vdc Extended Battery Cabinet User s Guide.

System 350 S350C Temperature Slave Stage Module

Use and Care Guide. Item #

MODELS. 2 & 4 Low Profile Linears


LAL SERIES LED LUMINAIRE

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

FLO Home TM X5 Model. Installation Guide

MAXLITE RKT LED Retrofit Kit

Feature Overview. For more information: or call toll free at

SloanLED THINLED. Constant Current. Installation Guide

User s Manual AKUNA THE VELOCIRAPTOR VTech Printed in China US

High Bay Luminaire Series

Elle Surface Mounting Instructions

MODELS 2 & 4 Top Conduit Linears

User s Manual. Clementine s Kitchen & Ice Cream Cart VTech Printed in China US. 500 IM_US.indd 1 08/05/ :48:5

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

- Wiring Brochure Zone Manager 335

Project. Comments. Prepared by

VR22-MU-xxx-8yy-xxxxA

MEDMASTER DOWNLIGHT Luminaires for Surgical Applications

960 Montage sur staff préfabriqué Mounting in prefabricated plaster

453X Series. Application. Features. Two-Position Damper Actuator General Instructions

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

Spun Bay Installation Standard Version (non dimmable), Hook Mount

Go! Go! Smart Friends

MODELS SafeSite LED Linear, Class I Div V, 2 & 4 Versions

User s Manual. Cruise & Learn CarTM VTech Printed in China US

VR44-MU-xxx-8yy-xxxxA

Installation Instructions MX LED Enhanced Color Adjustable

IMMERSION. GE Lighting. OEM Installation Guide. imagination at work. LED Display Lighting

Specification Grade Contemporary Wall Mount/Technical Installation Data

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Eaton Battery Charger Module Models ASY-0652 and ASY-0675 User s Guide

USE AND CARE GUIDE 15 INCH WHITE ROUND FLAT PANEL FIXTURE WITH SELECTABLE COLOR TEMPERATURE

USE AND CARE GUIDE 4 FT. LED WRAP LIGHT

Installation Instruction

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

Warning. 1. Have the installation done by a qualified professional, according to local electrical codes. 1. It may not cause harmful interference,

Cable Cubby 1202 and 1402 Installation Guide

User s Manual DIGGER THE WOOLLY MAMMOTH TM VTech Printed in China US

User s Manual BRONCO THE RC TRICERATOPS VTech Printed in China US

GETTING STARTED WITH IN-WALL DIMMER SWITCH

3 year warranty. (1) Treo Micro fiberglass, gunite fitting, 3/4 PVC. FLED-TM-W-PK10 (10) Treo Micros (WHITE) 80 NEW! Treo Micro fitting adapter

MONOPRICE. Power Cache 220 Solar Power Generator. User's Manual P/N 15278

User s Manual. Deluxe Car Carrier TM VTech Printed in China

- Wiring Brochure Zone Manager 336

VA-4233-AGx Series Electric Valve Actuators

Transcription:

GE Lighting Installation Guide Lumination TM LED Luminaires LAL Series - Continuous Run Option BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING/AVERTISSEMENT RISK OF ELECTRIC SHOCK Turn power off before inspection, installation or removal. Properly ground electrical enclosure. RISK OF FIRE Follow all NEC and local codes. Use only UL approved wire for input/output connections. Minimum size 14 AWG. Type IC, inherently protected. RISQUES DE DÉCHARGES ÉLECTRIQUES Coupez l alimentation avant d inspecter, installer ou déplacer le luminaire. Assurez-vous de correctement mettre à la terre le boîtier d alimentation électrique. RISQUES D INCENDIE Respectez tous les codes NEC et codes locaux. N utilisez que des fils approuvés par UL pour les entrées/sorties de connexion. Taille minimum 14 AWG. Type IC, protection inhérente. Save These Instructions Use only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. Important 120V 60Hz - maximum 50 feet of luminaires can be connected on a single through wiring run 220V 60Hz - maximum 100 feet of luminaires can be connected on a single through wiring run 277V 60Hz - maximum 150 feet of luminaires can be connected on a single through wiring run Please see technical data sheet for electrical properties to ensure safe installation Under any circumstance, maximum driver current through connected fixtures shall not exceed 7A Tools and Components Required For end cover install: Hex headed screwdriver Rigid (RMC) or flexible (FMC) metal conduit for supply connection UL/cUL approved twist-on-wire connectors, min. 14 AWG UL/cUL approved conduit fittings for 1/2 conduit trade size (2 pieces) For bracket to bracket fixing: Hex headed screwdriver Use LAL4x Series End Cover to terminate row Provided in the Package Luminaire Pre-installed knockout closure for 1/2 trade size conduit knockouts Universal mounting brackets (4 pieces) 8-18 x 3/8 screws for mounting bracket installation (10 pieces) Ceiling grid screw for grid and bracket fixing (4 pieces) 8-18 x 3/8 screws for bracket to bracket fixing (2 pieces) Primary diffuser Prepare Electrical Wiring Electrical Requirements The LED driver must be supplied with 120-277 VAC or 347VAC, 60 Hz and connected to an individual properly grounded branch circuit. Use min. 600V 75 C supply conductor. Grounding Instructions The grounding and bonding of the overall system shall be done in accordance with National Electric Code (NEC) Article 600 and local codes.

Electrical Connections 1 Carefully unpack unit from its packaging. Properly inspect for defects before installing. Wear work gloves to prevent dirt and oil from being transferred to the luminaire. 2 Gray Leader cable Violet Green/Yellow White 3 5 Connect to the AC line wire connectors to conduit attached to fixture with with conduit. Note: See under Continuous Run Installation for instructions on how to connect wiring between luminaires. with twist-on

Wiring Diagrams Optional Installation: 1-10 Volt Dimming or DALI Lighting Controller Follow diagram A for 1-10V, diagram B for DALI or diagram C f At output side of LED driver, make appropriate connections using twist-on wire connectors. Follow lighting controller installation instructions. Line (black) Neutral (white) Ground (green) Line Line (black) Neutral Neutral (white) Ground (1-10) + (violet) Neutral Ground (green) Ground DALI 1 (violet) DALI/(1-10V) + (1-10) - (gray) A (1-10V) - Line 1-10V B DALI (1-10V) DALI/(1-10V) + ) DALI 2 ( wiring diagram wiring diagram VIOLET (1-10V) + GREY (1-10V) Light Engine + RED BLUE RED BLUE + 347V Transformer Line BLACK Neutral WHITE (1-10) + (violet) (1-10) - (gray) Ground (green) Neutral (white) Line (black) C wiring diagram BLUE Line RED BLACK Neutral BLACK

continuous row to an emergency generator circuit First luminaire Thru wiring 1 Middle luminaire(s) Driver wires Last luminaire Emergency generator feed 2 Ensure power to luminaire is disonnected. Cut the 18AWG black and white wires from the driver. Connect the emergency generator feed to the driver (black to black and white to white). Cap any unused wires. Ensure ground connection. Purple (Thru Wiring) Gray 1-10V 1-10V + Line Black Neutral White White Black (Thru Wiring) Red Green NOTES 1. Follow all applicable codes and requirements. 2. For rows with multiple feed locations, ensure that luminaire sections connected to separate power sources are not connected to the internal wiring 3. For rows with external 0-10V dimming connections, separate dimming for separately powered luminaire segments if required by code to ensure proper operation in every intended mode of operation. 4. For rows requiring multiple feed locations that have internal controls, contact manufacturer.

Luminaire Installation Safety screw holes. One is needed, more are optional. The product is compatible with various type grids with the supplied universal bracket. Attach grid brackets. The screws should be in the same hole type. Insert four mounting brackets (two per side) into grooves on both sides of luminaire. Place starter fixture into grid system. Tighten 8-18 x 3/8 screws provided to attach Position brackets approximately 2-3 mm from ends. End cover No end covers First luminaire Middle luminaire(s) Ceiling grid Connect luminaires together in ceiling grid. Remove end cover from xture. End cover Last luminaire

Plug together wires between luminaires. Carefully align one luminaire with grooves of next luminiare, then push them completely together, taking care not to pinch wires. NOTE: A rubber mallet may be required to complete this step. Hammer the luminaires only on the top edge, not the bottom. One safety screw per bracket is mandatory, additional screws are optional 9 Join mounting brackets together with screw. Make 10 Slightly reposition brackets and join them again to For added safety, use additional ceiling grid screws ets to grid. WARNING Risk of Injury. Improper mounting bracket installation may cause injury or property damage. Use a star washer under one of the screws to ensure ground continuity 11 Fasten one end cover on the first and last luminaires only with two 8-18 x 3/8 screws. Always use a star washer under one of the top screws to ensure ground continuity. Use retained end covers, star washers and screws. NOTE: luminaire do not require end covers. Note for City of Chicago: Luminaires are designed to meet City of Chicago Environmental Air (CCEA) requirements. t, a sealant tape can be applied over the opening. Tape has to meet the requirements of UL181A-P and UL181B-FX standards and meet requirements for UL-723.

Diffuser Installation - optional Primary diffuser 1 Option - one diffuser (primary): diffuser into base of luminaire. Line up diffuser with fixture and snap in lens. Troubleshooting Symptom Solution Luminaire does not light Check input voltage and check power supply input/output connections. Check circuit breaker. Luminaire is dim Dimming wire connection shall be checked and if connection is not proper, reconnect it. If wire is harmed, replace it with an intact one. Also check that dimming wires are not in short circuit. Luminaire is blinking Ensure power supply temperature does not exceed its maximum rating. Refer to the tc point located on power supply. Luminaire does not dim Check dimming wire connection. Luminaires will not turn on Check that the color of the supply side wires match the color of the wires they are connected to. Check that the LED driver connector is fully engaged to the LED light engine connector. Check that the LED light engines are connected at the junction between the two luminaires. Luminaire on through wiring will not turn on fully engaged to the malfunctioning luminaire. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR de la classe [ A ] est conforme á la NMB-005 du Canada. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. www.currentbyge.com, www.gelighting.com All trademarks are the property of their respective owners. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions. Current, powered by GE is a business of the General Electric Company. 2017 IND306 (Rev 05/26/17)