FL B. Halogen light generator for Fibre optic lighting systems

Similar documents
FL Halogen light generator for use with fibre optic lighting. Mounting and installation instruction. Item no.: FL 20-2 Ø9 230V

F L B Metal Halide Light Generator for Fiber Optic Lighting Systems

FL 150 XT-2 B, F, and C

FL 1000 XT C DMX. User manual

RobLight FL User manual. Applies to: RobLight A/S Nordhavnsvej 1A DK Frederikshavn. Phone:

FL Roblon Lighting. User manual. Applies to: RobLight A/S Nordhavnsvej 1A DK Frederikshavn

Ara 4. Mounting and installation instructions. Item no.: Ara K black. User manual

Light Source User Guide

Light Source User Guide

USER MANUAL LUX-LD30W LED MOVING HEAD

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

LyteLaunch Dry - Wet and DMX Models. Operation Manual

Measurements are expressed in millimeters.

USER MANUAL PAR56 LED PAR CANS

Navigator ORDERCODE 40410

LED Twister II. User manual UK Version 1.0

D.fm Page 1 Wednesday, March 5, :21 PM Raptor user manual

Snapshot Ok on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX 512. Master/Slave. 115/230V Power Switch. Replaceable Fuse.

Snapshot LX10 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

LED Pinspot 2. Snapshot. User Manual

FiberSource Q150. user manual P/N

LED Pinspot 2. Snapshot. User Manual

HyperFlex 12G.

LED NEUTRON 4 x QUAD COLOUR LED LIGHT EFFECT

Microscope light manual

Mania EF1 user manual

SHARPY SPARE PARTS FINDER

CONTENT VIPP LAMPS : TIMELESS ILLUMINATION 4-5 IMPORTANT SAFETY INSTRUCTIONS 6-8 VIPP521 TABLE LAMP VIPP522 WALL LAMP 16-23

Sirius Illuminator Range

Snapshot. Use on Dimmer Outdoor Use Sound-Activated DMX Master/Slave 120 V/230 V Switchable Replaceable Fuse User-Serviceable.

Via Michelangelo Buonarroti, 52/B Cologno M.se (Mi) USER S MANUAL

USER S MANUAL TUBE SEALER. Model SE700. No. CAT.SE70011Ce

User Guide for Logo Projector

Mass Sine 24/10000 Mass Sine 24/15000

basic quattro No /

Actuator type ABNM with Theft Protection, 0-10 V Proportional

SOLUS 9 SPOTLIGHT - LED. Features Include. Applications. Benefits

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL

CH-158 Color Bank 8 USER MANUAL

P90L-ISO6MB & ISO10MB

STREET HIGH EFFICIENCY LED STREET LUMINAIRES MADE IN THE EU

ECO Spot 2500 User Manual

ECO Spot 2500 User Manual

IVIOS LED III. LUM Technical Information

Planning Low Voltage Layouts

Mini Aquatic ORDERCODE 30844

2014 / Verlichting

AMCON AUTOMATIC CHART PROJECTOR USER S MANUAL EQ-6002

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

FD 342 Document Folder

Fiber Optic Illuminator. Model 21AC Model 21DC

Buxie D. Ultra compact W MSD. Followspot. Type: Followspot Source: 575 W MSD PSU: Electronic - hot restrike Optics: 10,5 to 22,5 zoom

PAGE 1. TES Operation & Testing Guidelines: Tes Trouble shooting

FL15 FL50 FL100 USER MANUAL USER MANUAL FL15 PRODUCT OVERVIEW HARDWARE AND SET-UP. page 1

Indoor high bay. Industrial and Commercial High Bays

PLUTO SPOTLIGHT - LED. Features include. Applications. Benefits

Operating voltage 120, 230 V AC Air volume 24 m³/h (14.1 CFM) Rated power 13 W Size 1

Lucy Compact W HMI. Followspot. Type: Followspot Source: 1200 W HMI PSU: Magnetic - hot restrike Optics: 13 to 24 zoom.

MEDICAL LIGHTING. LED-lighting. green efficiency

Pyxis & Corvus. Launch brochure

OPERATION & MAINTENANCE MANUAL FOR SCEN-206 LED & MULTI-FUNCTION TYPE CENTRIFUGE PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION.

Table of Contents. Classifications.. 5. Installation.,12. Focusing..14. Operating Instructions..15. Charts Description Maintenance...

OUTDOOR TRACK. LABELS Assembled in America

INDUSTRIAL THERMAL MANAGEMENT. Filter fans FL-Series

L1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel

c-go 24V/6A 24V/8A 24V/12A

Mounting instructions Directions for use MAKROLUX. Halogen-spot lamp for consulting room and hospital

Operating Instructions Bedienungsanleitung Mode d emploi EWB EWB

OSRAM PUNCTOLED COB. LUM Technical Information. Tender text OSRAM PUNCTOLED COB K OSRAM PUNCTOLED COB K

HMI Components. Series. Indicator Illuminated pushbutton Mushroom-head pushbutton Key lock switch

LIGHTINGS For Furnitures LED, Halogen & Flourescent

PREHEATER. Instruction Manual


PS24/AC Volt AC 16 Amp

SZ2-ILA INSTRUCTIONS TRANSMITTED ILLUMINATION ATTACHMENT SZ-ADD SZ-POL-2 SZH-CLJ. Optional Modules

R820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017

MEDICAL LIGHTING. LED-lighting. green efficiency

Ego 01 Ego 02 Ego 03 Logo Projector user manual

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

ELECTRICAL SYSTEM RP-7

XENON POWER SUPPLY 4000 Watt Gladiator IV

REFRIGERATION COOLERS

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC A

USER S MANUAL TUBE SEALER. Model SE450. No. CAT.SE45010Ce

CX-SERIES ADVANCED BATTERY CHARGER

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC A AND PSC A

Manual for Inverter system type PCI05

HMR DUAL DUCT CABIN UNIT CABIN UNITS HMR. For passenger and crew cabins

OWNER S MANUAL POWER INVERTER

Smart 110 with built-in flashlight for 6 240Ah lead-acid batteries

Snapshot. Hurricane 1300 USER MANUAL F-1300

Troubleshooting Guide: 355 Lights (12V)

Troubleshooting Guide: 355 Lights (24V)

18VDC ESB6 Series Cordless Screwdrivers Operation Manual

Installation Instructions

Operating Manual. Follow all safety precautions!

POWER ACCESSORIES SOCKET ASSEMBLIES CIGARETTE LIGHTER PLUGS BATTERY DISCHARGE PROTECTOR VOLTAGE REDUCERS VOLTAGE CONVERTER VOLTAGE BOOSTER INVERTERS

Transcription:

FL 2002-2 B Halogen light generator for Fibre optic lighting systems User Manual These mounting instructions describes mounting and installation of the following products: Item no.: 0121 0100 FL 2002-2 B Ø28 100W 230V 0121 0101 FL 2002-2 B Ø9/Ø28 75W 230V 0121 0110 FL 2002-2 B Ø28 100W 120V 0121 0111 FL 2002-2 B Ø9/Ø28 75W 120V +99082054 21.01.2013

1. Introduction This manual serves you as a guideline to how the system is operated in the safest way. Following the recommendations in this guideline all contributes to: Enhanced functionality Extended lifetime of components Uninterrupted illumination Your Roblon halogen light generator, type FL 2002-2 B is intended for indoor use in fibre optic lighting systems using either glass and PMMA fibres. This light generator is prepared for use in cabinets or showcases, either closed or semi closed compartments. Contents 1. INTRODUCTION... 2 2. PRODUCT OVERVIEW AND PACKING LIST... 3 3. TECHNICAL INFO... 3 4. INSTALLING THE LIGHT GENERATOR... 4 5. FIXATING THE LIGHT GENERATOR TO THE SURFACE... 4 6. MOUNTING OF OPTIONAL COLOUR FILTERS.... 5 7. TROUBLE SHOOTING... 5 8. SPARE PARTS... 7 9. ACCESSORIES... 7 2

2. Product overview and packing list Contents of this box: - FL 2002-2 B - Adaptor kit Ø28 -> Ø9 (including allen key) - User manual 3. Technical info Light port size: Ø28 mm. Ø9 focus with the supplied adapter Fibre type: PMMA/Glass Supply voltage: 230-240 V / 50-60 Hz or 120 V / 60 Hz Lamps: 75W Philips type 14515, 3000K. 100W Philips type 6839/25H. 3400K. Power consumption: 75 W 69 VA 100 W 96 VA Power cord: Power cord Dimming: Leading or trailing edge. Ballast: Electronic Thermal protection: Yes, w/ auto reset. Cooling system: 12 VDC axial fan (60x60mm) Fan noise level: 29 db(a) Ambient temperature: 0-40 C Lamp type: Halogen Lamp life time: 75W 6000 hours 100W 2500 hours Lamp colour temp: 75W 3000K 100W 3400K Material: Anodised aluminium. Dimensions: (L x H x W) 195 x 85 x 70mm. Weight: 600 g. Safety approvals: CE CB cul us 3

4. Installing the Light generator 1. Mount the Ø9/Ø28 adapter on the harness common end. 2. Secure the set screw with the supplied allen key. 3. Insert the harness' common end fully into the light port on the light generator. 4. Tighten the finger screw at the light port. 5. Close the lid and tighten the finger screw. 6. Se to that the requirements of installation and ventilation are met. 7. Connect the supply cord to the main power supply. (If you are using a Ø28 harness, please disregard 1 and 2.) 5. Fixating the light generator to the surface 1. Loosen the finger screw at the top of the light generator to open the lid. 2. Be careful not to damage the lamp. Remove it if necessary. 3. Mount the light generator with one or two screws (not included) through the holes beside the lamp. 4. Refit the lamp and close the lid again. 4

6. Mounting of optional colour filters. (not included). 1. Loosen the finger screw and open the lid. 2. Mount the Colour filter. 3. Close the lid again and secure the finger screw. 7. Trouble shooting Symptom Cause Solution No light Is the power ON? Is the power cord properly connected? Is the light generator too hot? No light, but fan is running Is the lamp blown? Light switches ON and OFF The light output has diminished Is the light generator too hot while operating? Is the fan blocked? Is the fan broken? Is the lamp old? Are the filters dirty? Is the fibre harness common end dirty? Turn ON the power. Reinsert the power cord. Check with the installation instructions. Cool off for 10 minutes and try again. Replace lamp with new one. Check with installation instructions. Clear the airways. Replace the fan with a new one. Replace the lamp with a new one. Clean the filters with a damp cloth. Finish by wiping off with a dry lint-free cloth. Clean the harness common end with a damp cloth. Finish by wiping off with a dry lintfree cloth.

When Installing one or more light generators in a closed compartment The light generator need to breathe to keep cool. Ventilation holes must be made in the compartment corresponding to min. 29 cm² of air intake and min. 29 cm² of exhaust air. When using this installation method, the air intake and exhaust of the light generator must be separated. Use ventilation hose adapter, +78000510, for standard Ø60 mm flexible ventilation hose, to Guide the exhaust air out of the compartment. When doing so, it is possible to install the light generator in very small compartments. Mounting of ventilation hose adapter. (not included) 6

8. Spare parts Description Roblon item no.: Model designation Image Lamp +65127595 14515 from Philips (for 75W units) +65129905 6834/25H FO from Philips (for 100W units) Fan +64060122 KDE-1206PTV2 MS.A.GN from Sunon Heat filter +54001000 KG-2 Transformer +68105020 HTM105 from Osram (for 100W European units) +68105042 LET-151R from Lightech (for US units) 9. Accessories Description Roblon part no.: Model designation Image +78000190 Colour Filter, FL 150-3/FL2002-2B, yellow Colour filter +78000191 Colour Filter, FL 150-3/FL2002-2B, green +78000192 Colour Filter, FL 150-3/FL2002-2B, blue +78000193 Colour Filter, FL 150-3/FL2002-2B, red +78000197 CTC Filter, FL 150-3/FL2002-2 B, -500K CTC filter +78000198 CTC Filter, FL 150-3/FL2002-2 B, -1200K +78000199 CTC Filter, FL 150-3/FL2002-2 B, -900K Ventilation hose adapter +78000510 For connecting light generator to Ø60 mm flexible ventilation hose. 7

Roblon Lighting Tel: +45 9620 3366 Nordhavnsvej 1 Fax: +45 9620 3396 9900 Frederikshavn info@roblon.com Denmark Roblon accepts no responsibility for possible errors in printed and electronic material. Roblon reserves the right to alter or discontinue products without notice. 2012, Roblon A/S 8