Similar documents
Installation and Operating Instructions

Bypass level indicator With magnetic display Model BNA for nuclear power plants

Vibrating Level Switch TF 511, TF 611, TF 633

Magnetic switch For bypass level indicators Model BGU

Magnetic switch For bypass level indicators Model BGU for nuclear power plants

Level sensor Magnetostrictive, high-resolution measurement principle Model FLM-H, for sanitary applications

KSR Flow Switches

Reed sensor For bypass level indicators Model BLR

Level Sensors / Transmitters to measure of liquids media

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2

TORRIX Magnetostrictive level sensor

Magnetic float switch For vertical installation Model FLS

TUNGUS. POWDER FIRE-EXTINGUISHING MODULE MPP(N)-0.65-I-GE-U2 Passport and Manual instructions

TUNGUS. POWDER FIRE-EXTINGUISHING MODULE MPP(N)-5-I-GE-U2 Passport and Manual instructions

TUNGUS. ANNEX А (obligatory) THE RESULTS OF TECHNICAL MAINTENANCE Table А.1 - Information about reloading, reexamination. Executive (company, name)

MAGNETIC FLOAT SWITCH

(submitted by the Dutch delegation)

Measuring insert for resistance thermometer Model TR10-A

Installation and Operating Manual

ENGINEERING FLOW SOLUTIONS PROTECTION & CONTROL PANELS. Control ST series

SINGLE-TURN AND MULTI-TURN ELECTRIC ACTUATORS

Gas-actuated thermometer Highly vibration resistant Model 75, stainless steel version

Certificate of Approval NMI 12/1/8

ULTRASONIC FLOW SENSOR IFX-M4-01

Oriflow. Compact Orifice with HART communication. Operating instructions. A-EN RevC Latest Mod von 16

Float switch For industrial applications, with temperature output Model RLS-3000

Mini Pressure Transmitter HA7

Pressure balance Differential pressure version Model CPB5600DP

FUSES PN22 SERIES Technical description and user manual

Ultrasonic filling level sensor UFM 200 / 600 C2 / C4 / R / MD

Bimetal thermometer Model 52, industrial series

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module

POSITIONAL CONTROL SYSTEMS

Thermocouple with spring-loaded tip Model TC55

Float switch For horizontal installation, miniature design Model HLS-M

Gas-actuated thermometer with switch contacts Model 73, stainless steel version

ABB Instrumentation. Thermal Mass Flowmeter Sensyflow. Intelligent solutions for accurate gas mass flow measurement

Magnetic Level Gauges

Cable resistance thermometer Model TR40

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

Volumeter TRZ 03-K PRODUCT INFORMATION. Reliable Measurements of Gas

High Accuracy Bunker Blending / Bunker Control

KR 30, 60-3; KR 30 L16-2

Magnetic Level Gauges

Bourdon tube pressure gauge, copper alloy Panel mounting series Models and

Gas-actuated thermometer with switch contacts Stainless steel version Model 73

High Accuracy Bunker Blending / Bunker Control

SAFETY FUSES PP57U SERIES Technical description and user manual

Supplementary instructions Flanges according to DIN - EN - ASME - JIS - GOST Technical data. Document ID: 31088

tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement

Temperature multi-function calibrator Model CTM

Power supply unit PS-303

Robots. KUKA Roboter GmbH KR 500 FORTEC. With F and C Variants Specification. Issued: Version: Spez KR 500 FORTEC V3

Rule No. 1. Scope Definitions Periodicity of technical inspections Technical inspection Inspection requirements...

2008 Plastikest. The catalogue of production from MDF 2008

ROPE ELECTRIC PULLEY-BLOCKS

VIETNAM I. GENERAL INFORMATION RATIONALE FOR LEGAL METROLGY LEGISLATION REGULATORY BODY. Population Size million

PROTOCOL comparative ballistic tests of new types of ammunition for small arms

Ultrasonic Flow Meter Series Smart-IN US. Features. Description

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35

Metering systems 0483EN October 2013 Metering units for sanitary or service water

OPTIMASS 3000 Technical Datasheet

CATALOGUE. Flowmeters Measurement systems kids Filters. Group of industrial companies «EMIS»

SOUTH AFRICAN NATIONAL STANDARD

AVL CONTINUOUS FUEL BALANCE

KR 30, 60-4 KS; KR 60 L16-2 KS

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Infiniti jx35. Nissan Pathfinder. Infiniti QX60 RUN. Ñåðòèôèêàò ñîîòâåòñòâèÿ ¹ ÒÑ RU C-RU.AE56.B Part number: 4381-Е.

APPROVED. conducted the cross-validation ballistic test of ammunition provided for test STILETTO SYSTEMS LTD. Company.

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

FT-1000/FP-1000 FLOAT TYPE TANK GAUGES SIMPLE, RELIABLE, COST EFFECTIVE. The FT-1000 or FP-1000 series is a mechanical level gauge with a float.

Reinforcing steel bars

MOTOR DRIVE UNITS FOR TAP CHANGERS... 2 [ MOTOR DRIVE UNIT MZ 4.4 WITH SINGLE-PHASE EL. MOTOR ]... 3 DRIVE UNITS FOR REPLACEMENT...

ELECTROMAGNETIC FLOW METER AFLOWT MF Modification Lite M OPERATION MANUAL PART I

Resistance thermometer Without thermowell Model TR10-H

Thermocouple Model TC10-H without thermowell

Level Sensors with Reed Switch Chain Technology Model RMG

Bimetal thermometer Model 52, industrial series

TCM-2 Thyristor DATA Control SHEETModule DATA SHEET. TCM-2 Thyristor Control Module

mass flowmeter for compressed air

Quantometer MZ. Description

Transmitting Transducer. Gas/Air Velocity Range:

CONTOIL VZFA/VZOA , versions for higher requirements / applications

PERFORMANCE OF THE NEW PRIMARY TORQUE STANDARD MACHINE OF INMETRO, BRAZIL

Differential pressure transmitter PASCAL Ci4 Delta P

Differential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series

Fluid Power Fluid Power

Magnetic-inductive flow meter for hazardous areas

Threaded resistance thermometer With perforated thermowell model TW35 Model TR10-J

IOM. LP-100 & LP-200 Pulse Point TM Installation & Operation Manual

KR QUANTEC prime. Robots. With F and C Variants Specification. KUKA Roboter GmbH. Issued: Version: Spez KR QUANTEC prime V10 KR QUANTEC

Fuel level sensors Strela - Users manual. Fuel level sensors Strela. Users manual

TURBINE BYPASS SYSTEMS

Gas-actuated thermometer Model 73, stainless steel version

Witold Perkowski, Andrzej Irzycki, Micha Kawalec Borys ukasik, Krzysztof Snopkiewicz

Model FVP General Specification. Flanged Vortex Plate. Product Features

EAS822 (Contrac) Power Electronic Unit

Certificate of Accreditation

Hydraulic Deadweight Tester Model CPB5800

TCM-2 Thyristor DATA Control SHEETModule DATA SHEET. TCM-2 Thyristor Control Module

Transcription:

Translation FEDERAL AGENCY OF TECHNICAL REGULATION AND METROLOGY CERTIFICATE of Pattern Approval of Measuring Devices DE.C.29.004.A No. 19358 Period of Validity: until the 11 th of March, 2020 PATTERN NAME OF MEASURING DEVICES: Float-Level Gauges LME MANUFACTURER: Company "KSR KUEBLER Niveau-Messtechnik AG", Germany REGISTRATION No.: 28257-04 DOCUMENT FOR VERIFICATION: МП 28257-04 INTERVAL BETWEEN VERIFICATIONS: 2 years Certificate of pattern approval has been extended by order of the Federal Agency of Technical Regulation and Metrology dated: 11 th March, 2015, No. 277. Description of the pattern of measuring devices represents the mandatory annex to this certificate. Deputy Head of Federal Agency S. S. Golubev Series СИ No. 019373

Annex to the Certificate No. 19358 for Pattern Approval of Measuring Devices Translation Sheet No. 1 Sheets, total: 4 Measuring Device Designation DESCRIPTION OF THE PATTERN OF MEASURING DEVICE Float-Level Gauges LME Float-level gauges BLE (hereinafter referred to as "level gauges") are designated for measuring the levels of fluid media, including liquid foodstuff and explosive liquids, as well as interfaces of fluid media in tanks. Measuring Device Description The operating principle of level gauges is based on measurements of fluid level by means of the float that travels along the guide tube, inside of which there is a metal conductor (wave guide) or tuned-reed ruler with resistors. Depending on position of the float, the measuring transducer measures either the time between the point of ultrasonic pulse generation and reflected signal receipt, or the resistance in the circuit of in-line arranged resistors that represents the function of fluid level at actuation of reed relays. Subject to application conditions and the device version, the level gauge may comprise: level sensor (Е, А, R, N, F, I, NMG, FFG, KMS) that is distinguished by an absence or presence of a junction box, the type of connection to the tank being of explosion-proof or a conventional design according to temperature and pressure modes; measuring transducer installed in the junction box on the lever sensor (X, Т, S, М, А, 53), or located separately (MF, KFD, MU, MD, Tracker, Index); additional devices: sensor GW24 of level limit values, intermediate protective relays KR24 (KR230), power unit (SG, PLSC242), feed transformer KFD. The level sensor can be equipped with limit switches, as well as with the second float for measurements of interfaces between non-miscible liquid media, densities of which differ by more than 50 kg/m 3. The MD, Tracker and Index have the liquid crystal display for visualization of fluid level values. The appearance of the level gauge is illustrated in Fig. 1. Fig. 1: Appearance of the level gauge LME

Translation Sheet No. 2 Sheets, total: 4 Metrological and Technical Data Metrological and technical data of level gauges are provided in Table 1. Table 1 Data Name 1. Measurement range of fluid level depending on the guide tube diameter, mm: - 12 mm - 18 mm - 20 mm Data Value 250 to 3000 250 to 6000 250 to 5000 2. Limits of allowable absolute uncertainty of fluid level ± 2 to ± 20 1) measurements, mm: 3. Temperature of the working medium depending on the design version, С: - standard version 40 to 125 - special version 200 to 450 4. Ambient air temperature, С: Level sensor: - standard version 40 to 60 - special version 70 to 60 Measuring transducer: - MF, KFD, Index 20 to 60 - MU, MD 0 to 50 - Tracker 10 to 50 5. Pressure of working medium, MPa: - standard version 10 - special version 20; 42 6. Output signal: 0 to 20 ma; 4 to 20 ma; 0 to 10 V; 2 to 10 V; HART 7. Electric power supply, V: - AC voltage - DC voltage 8. Mass depending on the version variant, kg: - level sensor - measuring transducer 90 to 265 10 to 32 1 to 80 0.1 to 1 9. Overall dimensions, not more than..., mm: Level sensor: Measuring transducer: - MF, KFD, MU (height х width х length) - MD, Tracker, Index (height х width х length) Length: 3500; 5500; 6500. Diameter: 200. 20 х 90 х 115; 70 х 105 х 110 45 x 75 x 110; 96 x 48 x 172 Note: 1) in accordance with the purchase order

Translation Pattern Approval Mark Sheet No. 3 Sheets, total: 4 The pattern approval mark shall be typographically applied to the junction box as a label and provided as the cover page of the data sheet. Measuring Device Completeness Verification 1. Float-level gauge LME 2. Data sheet, operating manual 3. Verification methodology Verification shall be conducted in accordance with the document МП 28257-04 "ГСИ (State System for Ensuring Uniform Measurement). Float-type level gauges produced by the company "KSR KUEBLER Niveau- Messtechnik AG", Germany. Verification methodology" approved by the Federal State Unitary Enterprise All- Russian Research Institute of Metrological Service on the 26 th of October, 2005. Main verification facilities: calibration rigs for level gauges, with upper-range valuations of 1 to 6 m and uncertainty of no less than ±0,5 mm; retractable pocket rule with 1 mm graduation mark according to GOST 7502-98; DC milliampere meter for measurements in the range from 0 to 20 ma with a relative accuracy of no more than ±0, 05%. Data on Methodologies (Methods) of Measurements Data are provided in the data sheet for bypass float-type level gauges LME. Normative and Technical Documents Determining Requirements for Bypass Float-type Level Gauges LME GOST 28725-90 "Devices for level measurements of liquids and bulk materials. General specifications and testing methods"; Technical documents of the company "KSR KUEBLER Niveau-Messtechnik AG", Germany. Recommendations Regarding the Ranges of Application in the Field of State Regulation for Assurance of Uniformity of Measurements To be used when performing production control regarding adherence to the requirements of industrial safety established by the legislation of the Russian Federation with regard to the operation of a hazardous industrial facility. Manufacturer: Company "KSR KUEBLER Niveau-Messtechnik AG", Germany Address: Heinrich-Kuebler-Platz 1, 69439 Zwingenberg Tel.: +49 6263 87-0 Fax: +49 6263 87-99 E-mail: info@,ksr-kuebler.com

Translation Applicant: Closed J.-S. Co. "WIKA MERA" Address: 117526 Moscow, 101/3 Vernadsky-Ave., office 509/510 Tel.: +7 495 648-01-80, fax: +7 495 648-01-81/82 e-mail: info@wika.ru, www: http://www.wika.ru/ Sheet No. 4 Sheets, total: 4 Testing Centre Federal State Unitary Enterprise All-Russian Research Institute of Metrological Service (ФГУП «ВНИИМС») Address: 119361 Moscow, Russia; 46 Ozernaya-Str. Tel.: +7 (495) 437-55-77, tel./fax: +7 (495) 430-57-25 E-mail: office@vniims.ru, http://www.vniims.ru Reference is made to the accreditation certificate of Federal State Unitary Enterprise All-Russian Research Institute of Metrological Service (ФГУП «ВНИИМС») concerning the performance of tests of measuring devices with the purpose of approving Pattern No. 30004-13 dated 26.07.2013. Deputy Head of the Federal Agency of Technical Regulation and Metrology