HI HLPT SERIES LOAD POINT ASSEMBLIES OPERATION AND INSTALLATION MANUAL

Similar documents
INSTALLATION & MAINTENANCE MANUAL

INSTALLATION & MAINTENANCE MANUAL HI LPD SERIES LOAD POINT ASSEMBLY Calle Fortunada San Diego, CA

Porta-Tronic. Portable Scales. INSTALLATION GUIDE Version 2.0

HI LPRC03 Advantage Hermetic Rocker Load Points

PROVEX Installation Guide. Version 1.0

Using the LCT100 for Load Cell Troubleshooting

Load Cell Troubleshooting

LP4300 FLOOR SCALE OPERATION INSTALLATION AND SERVICE MANUAL

KM26z 20N; 50N; 100N, 200N, 500N, 1kN, 2kN, 5kN

Model B STRAIN GAGE LOAD CELL. Installation and Operating Manual

MINIATURE S-BEAM JR. LOAD CELL LSB200 MANUAL. 10 Thomas, Irvine, CA USA (949) EM ADVANCED SENSOR TECHNOLOGY, INC.

LOAD CELL TROUBLESHOOTING

C3600P AND C7200P OPERATION INSTALLATION AND SERVICE MANUAL PRECISION TON CONTAINER SCALES

Web Tension Technology

Reliant Series Floor Scale

Model M B. Strain Gage Load Cell. Installation and Operating Manual

INSTRUCTION MANUAL ANCHOR LOAD CELL. Model ANCLO

Part Number Revision NC, September High Temperature Velocity and Acceleration Sensor Operation and Maintenance Manual

GRAIN CART RETROFIT TRACK SLIDE-IN-HITCH SCALE SYSTEM

Instruction Manual August milltronics MSI BELT SCALE

ANATOMY OF A HARDY LOAD SENSOR

MSI SINGLE IDLER BELT SCALE

Engineering Specifications

Disclaimer. 11/ Rev. 2

Instruction Manual August milltronics MMI BELT SCALE

KD45 ±20N. Description

Motoweigh Dynamic In-motion Checkweighing System. Installation Manual

Defender 3000 Series Base Instruction Manual

What is the secret to our success?

L007 LIQUID LEVEL FLOAT SWITCH. Side-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

Fax or to SENTRAN Applications Engineering Group: (909) or

The platform is placed on the weighing platform using three or four height-adjustable elastomer bearings (EL 120), in order to avoid twisting.

S003 LIQUID LEVEL FLOAT SWITCH. Single or Multi-Point, Vertically-Mounted, Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

Manual No: Revision: F. Mag Probe Assembly Manual

SERVICE MANUAL Defender Bases Dry-use (B Series) Wet-use (V Series)

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

TRANSDUCER INSTRUCTION MANUAL... TYPE SLIM CELL TRANSDUCER. INSTRUCTION NUMBER: AO of 9

RoughDeck TM FXB Flexure Base Floor Scale. Installation/Operation Manual

Precision Load Cells. The World of Precision Made Force Transducers. A world of experience TEST AND MOTION SIMULATION

OPERATING INSTRUCTIONS

L-Series: LIQUID LEVEL FLOAT SWITCH. Single-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

Benchmark HD Series Heavy Duty Bench Scale. Installation Manual

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

Quality Since 1980 SERVICE GUIDE. Eliminator Series HD, HDL, HDR, SD EDrive Actuators, Inc. #FB6070 Linear Actuators

Safe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual

Model 124 Filter Minder & Model 124

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

Load Cells. For Test, Measurement, and Monitoring Requirements in Automotive, Aerospace, R&D, and Process Control Applications

GSE Tank Mounts. Integrated Tank Assembly (ITA) Model 6600 & 6700 Series LeverMount. User Manual

Model 616 Rotating Disk Electrode Instruction Manual

High Frequency SineWave Guardian TM

437/737 BENCH SCALE. INSTALLATION and MAINTENANCE MANUAL

Weigh modules Tank and hopper kits

Load Cell for Manually Operated Presses Model 8451

Cleveland-Kidder Ultra

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

AD592/592-10K Non-Room Sensors in BAPI-Box, BAPI-Box 2 or BAPI-Box 4 BA/592-x-(BB, BB2, BB4) Temperature Sensor Instructions & Operation

Instructions for Installing and Operating Clark Reliance EA100 Series Levalarm

K3D300 ±200kN. Description

EZ Mount 1. Load Cell Mounting Kit. Installation Guide

Installation and Operating Manual

Quarter Master Series 94 Actuator

FAIRCHILD T5420 DIGITAL-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions

Electric Actuator Installation, Operation & Maintenance Manual

L500 LIQUID LEVEL FLOAT SWITCH. Single or Multi-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

GRAIN CART RETROFIT BOLT-ON TYPE HITCH SCALE SYSTEM

K3D300 ±50kN. Description

OPERATING INSTRUCTION MANUAL

A22 / A6 MINIATURE FORCE SENSOR

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners.

UNIVERSAL SOLAR SYSTEM (USS) USER MANUAL. For Millennium Low Power Gas Detectors or other continuous loads less than 0.

CAT-1 Series 3. Installation Guide. The Valley Group, Inc. 871 Ethan Allen Hwy. Suite 104 Ridgefield, CT 06877

kyalfa Laval Weighing Systems UltraPure with digital beam load cell

LIQUID LEVEL FLOAT SWITCH. F7 Series INSTALLATION AND OPERATIONS MANUAL. Single-Point, Vertically-Mounted Liquid Level Float Switch

For Hazardous Locations

Guardian Battery Charger Series. Installation and Operations Manual Section 75

437/737 BENCH SCALE. INSTALLATION and MAINTENANCE MANUAL

SWB505 MultiMount. Right the First Time Safe, Accurate, Service Friendly. Right the First Time

Servicing and Troubleshooting Process and Inventory Weighing Systems

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Belt Scales Milltronics belt scales

Titan Series Portable Vehicle Scale

MAPNET II Transceiver Installation Instructions

Surepowr Series 100 Installation Manual

CO 2 Room Sensor in the BAPI-Stat 3 Enclosure with Common Ground Configuration

BAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series)

Instruction Manual AVTM for. Strip Chart Recorder Catalog Nos and

L312 LIQUID LEVEL FLOAT SWITCH. Multi-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

MILLTRONICS UNIVERSAL SCALE NIVERSAL SCALE Rev. 1.2

RP-4000 Reserve Power Control

MSI SINGLE IDLER BELT SCALE

Fairbanks Transport Scale

SWB505 MultiMount. SWB605 PowerMount. Right the First Time Safe, Accurate, Service Friendly. Right the First Time

Tension and Compression Load Cell Model 8435

GRAIN CART RETROFIT J-M TRACK SLIDE IN HITCH SCALE SYSTEM

GRAIN CART RETROFIT J-M 5.5 SPINDLE SCALE SYSTEM

contents (1) Be sure to read following warranty clauses of our product 1 (2) General operating instructions 2 User s Manual

Nor East. Instructions Safety Messages. Inspection. Parts. DeZURIK Service. Type 05 Pneumatic Actuator Used With Globe Valves

SHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual

Transcription:

HI HLPT SERIES LOAD POINT ASSEMBLIES OPERATION AND INSTALLATION MANUAL Corporate Headquarters 9440 Carroll Park Drive, Ste. 150 San Diego, CA 92121 Phone: (858) 278-2900 FAX: (858) 278-6700 Web-Site: http://www.hardysolutions.com Hardy Process Solutions Document Number: 0596-0239-01 Rev F Copyright 2012 Hardy Process Solutions, Inc. All Rights Reserved. Printed in the U.S.A. (941028)

Local Field Service Hardy has over 200 field technicians in the U.S., and more positioned throughout the world to assist you in your support needs. We also have factory engineers who will travel to your facility anywhere in the world to help you solve challenging applications. We're ready to support you with: Installation and start-up Routine maintenance and certification Plant audits and performance measurement Emergency troubleshooting and repair To request Emergency Service and Troubleshooting, Start-up, Installation, Calibration, Verification or to discuss a Maintenance Agreement please call 800-821-5831 Option 3 or Emergency Service after hours (Standard Hours 6:00 AM to 6:00 PM Pacific Standard Time) and weekends Ext. 1111. Outside the U.S Hardy Instruments has built a network of support throughout the globe. For specific field service options available in your area please contact your local sales agent or our U.S. factory at +1 858-292-2710. 1-2

Table of Contents Table of Contents - - - - - - - - - - - - - - - - - - - - i General Information - - - - - - - - - - - - - - - - - - - - - -1 Unpacking - - - - - - - - - - - - - - - - - - - - - - - - - - -1 Site Preparation - - - - - - - - - - - - - - - - - - - - - - - -2 Precautions - - - - - - - - - - - - - - - - - - - - - - - - - -2 Basic Engineering Principles for Positioning Load Point Assemblies - - - - - - - - - - - - - - - - - - - - - - - - -2 Typical Mounting Arrangements - - - - - - - - - - - - - - - -3 Load Sensor Orientation - - - - - - - - - - - - - - - - - -3 Round Vessel with 1 Load Point - - - - - - - - - - - - - -3 Round Vessel with 3 Load Point Assemblies - - - - - - - -4 Safety Rods - - - - - - - - - - - - - - - - - - - - - - - -4 Round Vessel with 4 Load Point Assemblies - - - - - - - -5 Replacing the Load Sensor - - - - - - - - - - - - - - - - - - -5 Removing the Load Sensor - - - - - - - - - - - - - - - -6 Installing a New Load Sensor - - - - - - - - - - - - - - -6 Troubleshooting - - - - - - - - - - - - - - - - - - - - - - - -7 Physical Checks - - - - - - - - - - - - - - - - - - - - - -7 Electrical Tests for Load Point Assembly Problems - - - - -8 Zero Balance Test - - - - - - - - - - - - - - - - - - -8 Bridge Resistance Test - - - - - - - - - - - - - - - -9 Resistance to Ground Test - - - - - - - - - - - - - - -9 Electrical Termination Cable Color Codes - - - - - - - - - - - -10 Model Numbers - - - - - - - - - - - - - - - - - - - - - - - -11 Three Leg Systems - - - - - - - - - - - - - - - - - - - -11 Four Leg Systems - - - - - - - - - - - - - - - - - - - - -12 Specifications - - - - - - - - - - - - - - - - - - - - - - - - -12 i

1-ii

CAUTION: UNPACK WITH CARE WHEN UNPACKING, DO NOT DISCARD THE PACK- ING CASE OR ANY PACKING MATERIAL, UNTIL THE CONTENTS OF THE PACKING CASE ARE INSPECTED AND CAREFULLY COMPARED WITH THE SHIPPING DOCUMENTS. IF ANYTHING IS UNSATISFACTORY, PLEASE NOTIFY HARDY IMMEDIATELY BY CALLING, FAX- ING OR E-MAILING TO: Customer Support Department HARDY PROCESS SOLUTIONS, INC. 9440 Carroll Park Drive, Ste. 150 San Diego, California 92121 Phone: (800) 821-5831 (858) 278-2900 FAX: (858) 278-6700 E-mail: support@hardysolutions.com Web Address: www.hardysolutions.com A RETURN AUTHORIZATION NUMBER IS REQUIRED BEFORE RETURNING ANY DAMAGED PRODUCT. CALL THE CUSTOMER SUPPORT DEPARTMENT TO GET THE NUMBER. YOUR COMPANY NAME, ADDRESS, TELEPHONE NUMBER, SERIAL NUMBER OF THE UNIT AND A BRIEF DESCRIPTION OF THE PROBLEM SHOULD BE READY WHEN CALLING. IN CASE OF DAMAGE DUE TO SHIPPING, NOTIFY THE DELIVERING CARRIER IMMEDIATELY FOR AN INSPECTION.

OPERATION AND INSTALLATION MANUAL Congratulations, on your purchase of the Hardy Advantage Load Point Assembly. This product, is engineered to set a new standard in load point assemblies. Hardy combined new innovations with previously extra cost features and just plain common sense features and provided you with optimum performance unequaled anywhere. General Information The Hardy HI HLPT Hermetic Load Point System is designed to provide accurate output in the most demanding applications. The load sensor performance exceeds IP68 and NEMA 6 Standards for Wash Down Resistance. The HI HLPT Advantage, Tension Load Point Systems are designed for use on low to medium capacity vessels. The pre assembled Tension Load Point System is specifically designed to eliminate the effects of unwanted forces resulting in exceptional load measuring accuracy. Each load point consists of a stainless steel load sensor which is truly hermetically sealed (gauge area and cable entry), Enhanced C2 Second Generation Calibration, matched mv/v and mv/v/ohm and a 1/4 inch conduit adapter. The load points are pre assembled at our factory eliminating any assembly in the field. Each load point is fitted with a grounding strap. The load points mounting hardware is available in either stainless or galvanized steel and consist of two (2) clevises, two (2) Clevis Pins with four (4) external retaining rings and two (2) rod end assemblies. Unpacking Do not remove the load point assembly from it s packaging until just before installation. Although the load sensor is designed for harsh environments, it is a precision instrument and should be treated as such. Inspect the box, packing and the load point assembly for any signs of damage that might occur during shipment. Since almost all of the load point assemblies are shipped F.O.B. our fac- Page 1

HI HLPT SERIES LOAD POINT ASSEMBLY tory, such damage is normally the responsibility of the carrier and should be reported to them. LOAD SENSOR CERTIFICATION SHEETS ARE AVAILABLE 24 HOURS A DAY AT OUR WEBSITE: http://www.hardysolutions.com Write down the serial number(s) on the inside of the back cover for reference when talking to Hardy Customer Service. Store this information in a secure dry location for future reference. Site Preparation All mounting surfaces for the base and loading plate must be level. The Load Point Assemblies in a system must be level to within +/- 0.5 o. Any welding should be done prior to installation of the load points. Precautions Always treat the Load Sensor as a precision instrument. Leave the load point assembly in its packaging until it is time for installation. NEVER CARRY OR SWING THE LOAD SEN- SORS BY THEIR CABLE. Never allow moisture to get into any interconnections. Basic Engineering Principles for Positioning Load Point Assemblies Load Points Assemblies should be positioned such that the load (weight) is distributed as evenly as possible between each load point assembly in the scale. When the installation does not allow even distribution of the load, select higher capacity load point assemblies. This does not effect the weighing accuracy of the scale. All load point assemblies must have the same capacity when used in one scale. Page 2

OPERATION AND INSTALLATION MANUAL Typical Mounting Arrangements Load Sensor Orientation FIG. 1: LOAD SENSOR ORIENTATION Round Vessel with 1 Load Point FIG. 2: ROUND VESSEL WITH 1 LOAD POINT ASSEMBLY Page 3

HI HLPT SERIES LOAD POINT ASSEMBLY Round Vessel with 3 Load Point Assemblies Safety Rods FIG. 3: VERTICAL TANK - 3 LOAD CELLS FIG. 4: SPACE REQUIRED FOR SAFETY RODS CAUTION: THE ORIENTATION OF THE TOP AND BOT- TOM CLEVIS ASSEMBLY MUST BE AT 90 AS SHOWN IN FIG. 4. IMPROPER ORIENTA- TION CAUSES THE CLEVISES TO MISALIGN. THIS CAN LEAD TO BINDING WHICH CAN Page 4

OPERATION AND INSTALLATION MANUAL CAUSE THE EYE END OF THE EYE BOLTS TO SHEAR AND/OR PRODUCE AN INACCU- RATE WEIGHT READING. Round Vessel with 4 Load Point Assemblies FIG. 5: 4 LOAD POINT ASSEMBLY NOTE: In case there is some doubt concerning load point assembly installation, contact your local Hardy Representative, Hardy Process Solutions, Application Engineering or Customer Support Department for assistance. Replacing the Load Sensor NOTE: Make sure that the rod ends are threading into the threaded holes smoothly and easily before final assembly. Page 5

HI HLPT SERIES LOAD POINT ASSEMBLY The type of installation will govern the method of locating, attaching and assembling the parts of a load point. The following is a typical installation: Removing the Load Sensor Installing a New Load Sensor Step 1. Step 2. Step 3. Step 4. Step 5. Step 6. Step 7. Step 8. Step 9. Step 1. Step 2. Step 3. Step 4. Step 5. Step 6. Step 7. Step 8. Step 9. Step 10. Check to be sure you have all the parts. Take the load off the load cell. Use a flat screw driver and push the retaining rings off the clevis pin on both clevis mounts. (See Fig. 6) Pull the two clevis pins out of the clevises and ball joints. (See Fig. 6) Slide the load sensor with the rod ends out of the clevis mounts. Use a box end or crescent wrench and loosen the lock nuts on both rod ends that are fastened to the load sensor. (See Fig. 6) Use a small piece of masking tape or chalk to mark the location of the lock nuts for reassembly. Use channel locks to loosen the rod ends. Remove both rod ends from the load cell. Get a new load sensor. Replace the rod ends and tighten with channel locks to the mark made by the masking tape or the chalk. Remove the masking tape or wipe off the chalk. Tighten the lock nut. Insert the ball joint of one of the rod ends between the jaws of the clevis mounting block. (See Fig. 6) Align the holes in the ball joint with the holes in the clevis. Slide the clevis pin through the clevis and the ball joint holes. Insert the retaining rings in the grooves on both sides of the clevis pin until the ring snaps onto the pin. Repeat Step 5 through Step 8 for the other clevis mounting block. Put the load back on the load point assembly. Page 6

OPERATION AND INSTALLATION MANUAL FIG. 6: ISO ASSEMBLY DRAWING Troubleshooting Physical Checks Before doing any electrical tests do the following: Step 1. Step 2. Visually inspect each load point assembly for physical damage. Look for distortions or cracks in all metal parts. Check all welds to be sure they are not cracked of have deep pot marks. Page 7

HI HLPT SERIES LOAD POINT ASSEMBLY Step 3. Step 4. Step 5. Step 6. Step 7. Check all cables for cracks, cuts or crimping. Check for any abrasions on the cables. Look for structural changes in the scale or supporting structures. Look for binding of any kind on the load point assembly. Refer to your Hardy Manual for information on how to troubleshoot using Integrated Technician. For your convenience this manual is available on the Hardy Web site at: http://www.hardyinst.com on the support page. If you do not have access to the internet, contact your local Hardy Representative for information as to where to get this and other manuals for Hardy products. Get the Load Sensor certification sheets for referencing while troubleshooting. The certifications are available to you 24 hours a day at our Web Site: http://www.hardyinst.com If you find any of the problems stated above, replace the part that is damaged. Electrical Tests for Load Point Assembly Problems Zero Balance Test Problem: Changes in the Zero Balance. Cause: Load Cell has been overloaded. Remedy: Step 1. Use a millivolt meter or the Integrated Technician feature of the HI 2151/30WC (See Physical Checks, Step 6) and measure the LPS output under no load conditions. The reading should be less than 1% of the full scale output. NOTE: Sensors can shift up to about 10% of their full scale and still function correctly. Page 8

OPERATION AND INSTALLATION MANUAL Step 2. If the output has shifted more than 10%, replace the sensor. Assumption: A 5VDC excitation on a sensor with a 3mV/V output sensitivity, a 1% shift in zero balance will yield a.1mv/v change from the specification. Bridge Resistance Test Problem: Changes in Bridge Resistance Cause: Failure of a compensating element, or by a broken or burned bridge wire. Often cause by an electrical transient such as lightning. Remedy: Step 1. Step 2. Use an Ohmmeter and measure the resistance between the EXC + and EXC- leads. The value for the EXC leads should be 1106 ohms + - 5 ohms. Use an Ohmmeter and measure the resistance between the SIG + and SIG - leads. The value for the SIG leads should be 1,000 ohms + - 1 ohm. Step 3. Readings that exceed the ranges indicated suggest damage and the load cell should be throroughly inspected or replaced. Resistance to Ground Test Problem:Electrical leakage is creating an unstable output from the instrument. Cause: Water contamination in the load sensors or cables. Remedy: Step 1. Tie together the load sensor excitation (2), signal (2) and ground (1) wires. NOTE: Be careful NOT to include the two C2 wires. Page 9

HI HLPT SERIES LOAD POINT ASSEMBLY Step 2. Use a megohmmeter and measure the resistance between all five wires tied together and the load cell metal body. The measured value should be 5,000 megohms or more. WARNING WHEN USING A MEGGER DO NOT EXCEED 50 VOLT RANGE. If the sensor fails this test remove the ground wire and test with only the four live leads. If the sensor passes the test an insulation problem in the cable is most likely. Step 3. Replace the load cell if the cell fails both tests. Electrical Termination Cable Color Codes The cable is 6 conductor, shielded (floating) and 20 feet in length. EXC+ Red EXC - Black SIG + Green SIG - White C2+ Gray C2- Violet SHIELD Yellow WARNING LOAD CELL CABLE LENGTH HAS BEEN CALCULATED INTO C2 CALIBRATION DATA. HARDY PROCESS SOLUTIONS REC- OMMENDS THAT YOU DO NOT CUT YOUR ADVANTAGE OR ADVANTAGE LITE LOAD SENSOR CABLE, AS YOUR C2 ACCURACY WILL BE AFFECTED AND THE WARRANTY WILL BE VOIDED. Page 10

OPERATION AND INSTALLATION MANUAL Model Numbers NOTE: The -43C indicates a stainless steel load sensor with stainless steel mounting hardware. For galvanized mounting hardware use -45 C Capacity Model # Model # LBS Kn Fixed Assembly Spare Load Sensor 225 1 HI HLPT225-43C HI STH06-225 450 2 HI HLPT450-43C HI STH06-450 1,125 5 HI HLPT1125-43C HI STH06-112K 2.25K 10 HI HLPT2.25K-43C HI STH01-2.25K 4.5K 20 HI HLPT4.5K-43C HI STH01-4.5K 11.25 50 HI HLPT11.25K-45C HI STH01-11.25K TABLE 1: MODEL NUMBERS & CAPACITIES Three Leg Systems Total Capacity Model # Pounds Kn HI 3T675-43 675 3 HI 3T1.35K-43 1.35K 6 HI 3T3375-43 3.375K 15 HI 3T6.75K-43 6.75KK 30 HI 3T13.3K-43 13.5K 60 HI 3T33.75K-45 33.75K 150 TABLE 2: THREE LEG SYSTEMS Page 11

HI HLPT SERIES LOAD POINT ASSEMBLY Four Leg Systems Total Capacity Model # Pounds Kn HI 4T900-43 900 4 HI 4T1.8K-43 1.8K 8 HI 4T4.5K-43 4.5K 20 HI 4T9K-43 9K 40 HI 4T18K-43 18K 80 HI 4T45K-45 45K 200 Specifications Operating Specifications TABLE 3: FOUR LEG SYSTEMS Rated Output (F.S.) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2+-0.002mV Non-Linearity- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - +-0.018% R.O. Hysteresis - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - <+-0.025% R.O. Zero Balance - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - <+-1.0% R.O. Creep @ 5 Min. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - <+-0.01% R.O. Temp Effect Output- - - - - - - - - - - - - - - - - - - - - - - - - - - - - <+-0.0014% R.O./C Temp Effect Sensitivity - - - - - - - - - - - - - - - - - - - - - - - - - - <+-0.0007% R.O./C Input Resistance - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1050 to 1200 Ohms Output Resistance - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1000 +- 1 ohm Insulation Resistance - - - - - - - - - - - - - - - - - - - - - - - - - - - - >5000 megohms Excitation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-15VDC Safe Load Limit - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 200% Emax Ultimate Load - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 300% Emax Safe Side Load - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 100% Emax Page 12

OPERATION AND INSTALLATION MANUAL Environmental Specifications Operating Temperature - - - - - - - - - Minus 40 o F to Plus176 o F (-40 o C to +80 o C) Compensated Temperature - - - - - - - 14 o F to 104 o F (Minus 10 o C to Plus 40 o C) Load Sensor Material - - - - - - - - - - 17-4PH Martensitic (Magnetic) Stainless Steel Load Sensor Fittings - - - - - - - - - - - Coated Tool Steel Top Plate & Base Plate Material - - - 316 Stainless Steel or Galvanized Steel Conduit Adapter - - - - - - - - - - - - - -.250-18 NPT Hermetic Sealing Gauging Area - - - - - - - - - - - Welded Cylindrical Sleeve Cable Entry - - - - - - - - - - - - Glass to Metal Header Page 13

HI HLPT SERIES LOAD POINT ASSEMBLY Please print the unit serial number and model number for reference when ordering parts for the HI HLPT Load Point Assembly The serial number can be found on the side of the load sensor, or by entering the SelfTest Mode of the HI 2151/30WC. Scale Name/Location: Model Number: Serial Number 1: Serial Number 2: Serial Number 3: Serial Number 4: Serial Number 5: Serial Number 6: Page 14