Foam Supply Kits FOAM EDUCTORS FOAM EDUCTORS FOAM EDUCTORS FOAM SUPPLY KITS

Similar documents
Foam Supply Kits FOAM EDUCTORS FOAM EDUCTORS FOAM EDUCTORS FOAM SUPPLY KITS

MONITORS DESCRIPTION. Grease fitting for lubrication

DEMA MODELS P203CTC.PI.1,.2,.3 INSTALLATION INSTRUCTIONS

DEMA SPRAY CLEAN DISPENSERS MODEL 605T INSTALLATION INSTRUCTION

DEMA SPRAY STATION II MODEL 606T-2 INSTALLATION INSTRUCTIONS

MANUAL FOAM SYSTEM MODELS: MFA200 CLASS A FOAM MFA201 CLASS B FOAM MFA220 CLASS A and B FOAM

3061, 3096, 3126 foam systems gpm Installation Instructions

Page 6-6. Page 6-3. Page 6-3. Page 6-5. Self- Educting Foam. Foam Compatible. Location

DEMA MODELS 606T INSTALLATION INSTRUCTIONS

BATHROOM M-Series Full Thermostatic Shower System with Diverter Valve (Rough & Trim) GR2.212SG-C15E0

BATHROOM M-Series Full Thermostatic Shower System with Diverter Valve GM2.122SG-LM40E0

DEMA MODEL 603T-WI INSTALLATION INSTRUCTIONS

BATHROOM M-Series Full Thermostatic Shower System with Diverter Valve GM2.112WG-LM40E0

SHOWER M-Series Full Thermostatic Shower System with Diverter Valve (Rough & Trim) GP2.212WG-1C1L

Hose Racks HOSE RACKS & REELS HOSE RACKS & REELS HOSE RACKS

BATHROOM M-Series Full Thermostatic Shower System with Diverter Valve GM2.112WG-LM39E0

B-1125 DANKO STOCK. DANKO XL SKID UNIT UPF Defender Poly Tank

SALLE DE BAINS Thermostat 3/4 - corps ŕ encastrer G-8006

DEMA MODEL 606T-WI INSTALLATION INSTRUCTIONS

BATHROOM Square Water Feature System w/diverter Valve GH5.125A-LM38S Old code: GH5.125A-LM38S

DOUCHE Thermostat 3/4 - corps ŕ encastrer G-8006

BATHROOM Round Water Feature System w/diverter Valve GK5.125A-LM24S Old code: GK5.125A-LM24S

SALLE DE BAINS Thermostat 3/4 - corps ŕ encastrer G-8006

DANKO STOCK B DANKO XL SKID UNIT 250 Gallon UPF Defender Poly Tank

BAÑO Termostato 3/4 empotrado parte interna G-8006

ВАННАЯ КОМНАТА Замыкающий 2-х ходовой клапан 3/4 - наружные элементы G-8052

DEMA MODEL 604T-WI INSTALLATION INSTRUCTIONS

Spray Clean 606T-2 Installation Instruction

The 606T-2 unit is designed to be used as a spray or foam unit where up to two chemicals can be attached to the unit along with a clean water rinse.

ВАННАЯ КОМНАТА Термостатический переключатель 3/4 внутренний элемент G-8006

DOCCIA M-Series Full Thermostatic Shower System (Rough & Trim) GP3.212WH-C15E0

Installation Instructions

Industrial Pumping Equipment PowerMaster III

SPEAKMAN. SE-675 Installation, Operation, and Maintenance Instructions SAFE-T-ZONE EMERGENCY SHOWER AND EYE/FACE WASH

215 Gallon Waste Oil Tank With Metering Pump Installation Instructions

ERWC RM Shown with Optional Akron Brass Junction Box and Guide Roller

SHOWER Full Round Thermostatic Shower System GK1.123A-LM42S

PRODUCT LINEUP CHIEF XD NOZZLES XD SHUTOFFS XD SMOOTH BORES. your safety. our mission. June 2017

DEFENDER Series Foam Concentrate Tote Trailers

3061, 3096, 3126 FOAM SYSTEMS GPM INSTALLATION INSTRUCTIONS

NYLON & PVC VALVES MINING DIVISION PRESSURE REDUCING VALVES ENSURE DOWNSTREAM PRESSURE PVC NYLON

DEMA MODEL 692T FOAM STATION I INSTALLATION INSTRUCTION

HEAVY-DUTY VALVES. *Limited to Manufacture Defects. Operating Pressure (psi) " Stainless Steel " Polymer

DEMA RAPID FIRE MODELS 6300, , , , 6310, 6300H 6300E, 6300EH, &6310E INSTRUCTION SHEET

3061, 3096, 3126 foam systems gpm Installation Instructions

aquakit U Specifications Last revision: 09/07/2016 aquabrass.com

UltraJet Nozzle. AKRON BRASS COMPANY PH ( ) akronbrass.com

ACCESSORIES & FITTINGS 800 SERIES CONTROL VALVES

aquakit U Specifications Last revision: 09/07/2016 aquabrass.com

BASIC FOAM FIREFIGHTING OPERATIONS Red and Green Systems

Lightweight Aluminum Alloy Adapters

Spray & Foam Dispenser Item #

OPTIONS SLIP-ON FIREFIGHTING UNITS

DEMA Pro-Fill II Sink Dispenser

To establish a standardized procedure for Class B foam application by engine companies.

Inverted Dual High-Pressure Fluid Filter Assemblies

OPTIMUS SE-1200 SE-1250 SE-1255

Dilution Control Systems. 2-Button Station Model OPERATION SERVICE PARTS CARE

SCAN IT, WATCH IT! Smartphone video link. Multiple Flow Settings. High Visibility Reflective Operating Labels. With or Without Pistol Grip

DEMA Pro-Fill I Sink Dispenser

3.1 DISPENSER BLACK SHADOW SERIES. Tools Needed for Mounting SCS Dispenser Hammer

Instructions for Installation, Operation, Care and Maintenance

HOSES & LANCES. Hoses & Lances 15,000 PSI (1,034 BAR)

:,Rhino SD/XD G/D 24 Vdc ISO

ADAPTERS & VALVES CAPS GASKETS STORZ ADAPTERS THREADED ADAPTERS. /adapters 2 1 /2" 3" 4" 4 1 /2" 5" 6" AC728: Male

DIGIFLO ELECTRONIC FLOWMETER

Applications Closed Head Foam-Water Sprinkler Systems Aircraft Hangars Flammable Liquid Warehouses, Drum Storage Facilities

Troubleshooting WARNING

TECHNICAL DATA. Trimpac 244a. April 15, 2011

FRS Dispenser (Foam-Rinse-Sanitize) Model # ol Systems. Dilution Control OPERATION SERVICE PARTS CARE

AKRON BRASS COMPANY PH ( ) FAX ( )

Installation Instructions

Installation, Operation & Maintenance Instructions for MF-Solar Series Solution Feeders

ALLSTAR DILUTION CONTROL SYSTEM MODEL 639AG-4-1ABC

DATA SHEET 4DX10ER, 4DX15ER, 4DX20ER, 4DX27ER, 4DX30ER DIRECT DRIVE PLUNGER PUMPS. Brass Electric Models: SPECIFICATIONS U.S. Measure Metric Measure

WAFER STYLE ILBP PROPORTIONING MODULES WITH CHECK VALVE. NPR160 Approvals: UL, ULC

DEMA MODEL 693T FOAM STATION II INSTALLATION INSTRUCTION

Instructions for Installation, Operation, Care and Maintenance

PumpAgents.com - Click here for Pricing/Ordering Fuse Size (A) Open Flow GPM (LPM)

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

Installation Instructions

B Pump Mounting. Page 1 of 7

ВАННАЯ КОМНАТА Concealed Pressure Balancing Valve Rough w/diverter G-7055

PPM EO-100 TM. Operation Manual

Tools Needed for Mounting Cleá Filling Station

TRANSFER PUMP INSTRUCTIONS P/N 14251NOS

1 1/4 NPT FILTER SIZE DESIGNATION PRICE 2 NPT FILTER REPLACEMENT SCREENS FOR 1 1/4 & 2 FILTERS 1 1/4 SCREENS 2 SCREENS HOLE SIZE DESIGNATION PRICE

PG-35AV-CH Coiled Hose and Spray Valve. PG-8WSAV-08 Lighweight Aluminum Spray Unit

Installation Instructions

SPEAKMAN SAFETY PRODUCTS Installation, Maintenance & Operation Instructions SEF-1000 EYESAVER FAUCET DESCRIPTION

Ball & Socket Fittings (Bauer Style)

Mini Fire-Ball 225, 50:1

Head to Head Demo Comparison Sheet

Intended Use: Explanation of Signal Word Consequences

Hose & Apparatus Test Equipment

AIR SHOWER & TUB REP

PeroxiDraw Dispenser

Darley UHP-HV Diesel Specification 1

WHY DO YOU NEED FOAM?

Used for Safety Shower combination stations: SE-603 SE-616 SE-690 SE-693 SE-695 SE-697

Transcription:

FOAM SUPPLY KITS Foam Supply Kits Elkhart offers two supply kits. Both kits include: One.75 quarter-turn, inlet valve assembly with elbow Quick-connect female coupling Quick-connect plug with chain Brushed stainless steel escutcheon plate Foam pick-up hose assembly with quick-connect male coupling 3-1 KIT 1 KIT 2 (P/N 81231001) Kit 1 is a built in by-pass foam eductor to utilize an off-board foam concentrate supply either when the on-board supply has been depleted or to allow use of another type of foam concentrate. (P/N 81232001) Kit 2 allows the use of an on-board foam concentrate tank with a separate portable foam eductor (such as Elkhart s 240 and 241 series) attached to a pump side discharge; permits easy switching from alternative supply to the on-board supply tank and back as necessary.

PORTABLE Portable Elkhart offers an eductor for all handlines (1 through 2 1 /2 ) and the eductors are compatible with most foam concentrates. All Elkhart s eductors: Are easy hook-up / easy set-up Feature red urethane enamel finish Can be deployed in any position Offer a removable pick-up screen and removable metering valve Comes with a clear PVC pick-up hose 3-2 BRASS BY-PASS INLINE EDUCTOR MO. 240 Fig. 1 BRASS INLINE EDUCTOR MO. 241 Fig. 2 COMPOSITE INLINE EDUCTOR MO. 242 Fig. 3

PORTABLE TYPE By-pass INLET SIZE OUTLET SIZE 1 1.5 2.5 1 1.5 2.5 30 (114) FLOW RATES GPM (LPM) 60 (227) 95 (360) 125 (473) 150 (568) 250 (946) Fixed METERING Selectable Positive Infinite 3% 6% 0% / 1 / 2% / 1% / 3% / 6% 0%-6% MATERIAL / TRIM Brass Chrome Rough Satin Composite s 17.25 20.5 240-60 1 s 17.25 20.5 240-95 1 s 17.25 20.5 240-125 1 s 8.375 4.5 241-30 2 s 10.00 5.8 241-N3* 2 Length (Inches) Weight (Lbs.) MODEL FIGURE Inline s 10.00 5.8 241-N6* 2 ** s 4.625 0.5 242-95** 3 o s 11.75 9.5 241-60 2 o s 11.75 9.5 241-95 2 o s 11.75 9.5 241-125 2 o s 11.75 9.5 241-150 2 o s 16.0 16.8 241-250 2 4-3 3-3 KEY s = standard o = option * Inlet and outlet threads are NPSH; ID is 3 /4 ; ribbed hose length is 54 ** Supplied with fixed metering valves at 1 /2%, 1%, and 3% and an adjustable metering valve with 1 /2% / 1% / 3% settings. GPM (LPM) NOTE Eductor and nozzle must have matching flow rates (gpm/lpm) for the foam concentrate to pick-up. See page T-1 for Eductor Performance Chart. Operating Pressures of Eductors These eductors are designed to achieve rated flow with an inlet pressure of 200 psi (150 psi for the 242-95). They will operate at lower inlet pressures, but the flow rate and percentage rate will be affected. Checklist if eductor fails to pick up foam Ball check stuck By-pass valve open Clogged nozzle Hose lay too long Kink in hose Metering valve clogged Metering valve closed Metering valve set improperly Mismatched nozzle Nozzle elevated too high Partially closed nozzle Plugged pick-up screen ADDITIONAL INFORMATION S INFINITE SETTING POSITIVE SETTING HOSE LENGTHS 240 models and most 241 models are 36 241-N models are 54 241-250 model is 72

BUILT-IN 4-4 3-4 Built-In Elkhart offers built-in foam eductors for all handlines (pipe sizes of 1.5 and 2 ), and the eductors are compatible with most foam concentrates. The built-in eductors come furnished with valves, fittings and accessories for installing permanently behind the panel in pump compartment. Package includes: One (1) 240 by-pass eductor One (1) 890-01-01-D 1.00 inline valve Two (2) 775-15 tee handles Two (2) 775-11 rod guides One (1) thru the panel metering valve with 5 settings (0%, 1 /2%, 1%, 3%, and 6%) One (1) ball check valve One (1) brushed stainless steel instruction plate (with hardware)

BUILT-IN FROM PUMP NPT INLET / OUTLET* 2.0 KEY s = standard o = option * Victaulic available Typical Installation 240-P EDUCTOR 60 (227) FLOW RATES GPM (LPM) 95 (360) 125 (473) LENGTH (Inches) PACKAGE WEIGHT (Lbs.) MODEL NUMBER s 17.25 32.9 240-60P s 17.25 32.9 240-95P s 17.25 32.9 240-125P MINIMUM OF FIVE PIPE DIAMETERS STRAIGHT PIPE OR EDUCTOR DISCHARGE TO DISCHARGE.625 MIN. I.D. PIPE OR HOSE BALL CHECK 1,000 MIN. I.D. PIPE OR HOSE 2 MINIMUM I.D. PIPE OR HOSE FOR 125 GPM EDUCTORS TO FOAM TANK 3-5 4-5 ADJUSTABLE METERING DEVICE NOTE: Items listed in purple type are included in package. PULL-OUT FOR FOAM BY-PASS FLUSH LINE 890-01-01-D 1 775-11 ROD GUIDE 775-15 TEE HANDLE FOAM PULL-OUT FOR FOAM Operating Pressures of Eductors These eductors are designed to achieve rated flow with an inlet pressure of 200 psi. They will operate at lower inlet pressures, but the flow rate and percentage rate will be affected. Checklist if eductor fails to pick up foam Ball check stuck Eductor handle not pulled out Excessive friction loss between eductor and discharge outlet Foam tank empty Hose lay too long Metering valve clogged with dry foam Mismatched nozzle Clogged nozzle Elbow plumbed too close to inlet/outlet Foam handle not pulled out Foam tank not vented Kink in hose Metering valve set improperly Partially closed nozzle Too much nozzle elevation