Installation and operation

Similar documents
INSTALLATION MANUAL ROAD GATE BARRIER BARRIER-5000

contents Installation Maintenance DOOR OPERATOR SLIDING-1300/2100 Installation and Operating Manual DoorHan, 2012

contents OPERATOR Maintenance SHAFT-120 Installation and Operating Manual DoorHan, 2012

OPERATOR SHAFT-120. Installation and Operating Manual CONTENTS GENERAL INFORMATION SAFETY INSTRUCTIONS OPERATOR UNIT OPERATOR INSTALLATION

DKC400Y AC Sliding Gate Installation Manual. Sliding Gate Opener. Model: DKC400Y. Installation Manual WARNING

Sliding Gate Operator User's Manual

Sliding Gate Operator User's Manual

SKC400U SLIDING GATE OPENER OWNER S MANUAL

Instruction Manual for the. E-SL 450 Series

1 ABOUT THE COMPANY. DoorHan Company Group. kadan. suzhou

Owner s Manual. For SOLAR BOOM GATE. Model: CA-5000 SOLAR

BAYT 980. Oil-hydraulic OIL-HYDRAULIC BARRIER FOR TRAFFIC CONTROL INSTALLATION MANUAL. code 4425 Post with fixing base. POLO 44 - optional -

DESIGNED FOR RESIDENTIAL APPLICATION KIT PL600/PL1000 SLIDING GATE OPENERS

MBM8 / MBM11- Barriers. Installer and User s manual

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

PY600AC Sliding Gate Opener User Manual

USER MANUAL. Automated Vehicular Boom Gate. Version: 1.0 Date: March, 2015

TECHNICAL DATA HYDRAULIC UNIT

Sectional And Tilting Door Opener

D Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES

GARAGE DOOR OPENER OWNER S MANUAL S3/S4

Letron Auto Gates (Australia) Pty. Ltd. User s Installation Manual

KVM 25 OPERATION MANUAL / INSTALLER

VERG 24V BARRIER. English

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

BARRY BARRIER GATE AUTOMATION

INSTALLER AND USER S MANUAL. v4.0 REV. 01/2019

Table of Contents. General Safety Preparation for Installation Parts List Optional Accessories Part List... 5

Sliding Gate Operator. User's Manual WARNING THIS PRODUCT MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN

ROSSO EVO User s and Installer s manual

All our door components are designed for use in a range of climate conditions

Sliding Gate Opener User s Manual

PLD86 New generation stepper motor driver

EC DECLARATION OF CONFORMITY

PowerMaster MODEL MBG. Installation Manual U L R UL 325 AND UL 991 LISTED MEDIUM DUTY BARRIER GATE OPERATOR TABLE OF CONTENTS

Installation manual ASTER AUTOMATION FOR SWING GATES 11_16

CONTROL UNIT BIOS2. Manual for installation. Programmable Control board for wings gates.

FITTING AND CONNECTION INSTRUCTIONS

ROSSO EVO USER'S AND INSTALLER'S MANUAL. v2.3 REV. 01/2015

PLD545-G3 New generation stepper motor driver

INSTALLATION M ANUAL

Roller Door Operator

Installation and Set Up Instructions

Barrier Gate Manual. (DZX2.1 Control Board) (The third version) (Pictures for reference only, the product prevail in kind)

LIFTMASTER MAGIC BUTTON FS10 & LPK5 FAST SLIDER

PLD545 Stepper motor driver

PW320/PW330 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL. Flashing Light. Push Button. Control box. Gate 2.

Installation and Set Up Instructions

TITANO 400V SLIDING GATE OPENER

MOUNTING AND CONNECTING INSTRUCTIONS 1. GATE ARRANGEMENT ENGLISH

SWING GATE OPENERS 24V DC GEAR MOTOR

Istruzioni, instructions. Motoriduttore a braccio snodato per cancelli battenti Gear motor with articulated arm for swing gates ALPHEO

PURE SINE WAVE DC TO AC POWER INVERTER

APOLLO Gate Operators, Inc.

User Manual of Bagibike Electric Bicycles

GARAGE DOOR OPERATOR USER S MANUAL

AgriWheel Single Gate Kit Low Voltage & Solar. Installation & Operating Instructions

NOVATEK-ELECTRO LTD Research-and-Manufacture Company Voltage Stabilizer Legat-35

AUTOMATIC CONTROL ROLLING DOOR OPENER

MICROPROCESSOR SYSTEM EQMPP. Installation Manual. V 1.2 June 5 th ELETTROQUADRI S.r.l. Via Puccini, Bisuschio (VA) - Italy

Intelli-Park Series Barrier Arms. Intelli-Park 9. Intelli-Park 14. Intelli-Park 18. Intelli-Park 32

PowerMaster Model SG

CHUBBSAFES EVOLVE INSTRUCTION MANUAL

SLIDING GATE OPENER USER MANUAL

Bi-Directional Progressive Safety Gear

Table Of Contents. Motor Selection Guide Installation Instructions Operators 20-32

Legat-65. Voltage Stabilizer Technical Certificate. NOVATEK-ELECTRO LTD Research-and-Manufacture Company

INSTRUCTION INVERTER COMPACT FOR SLIDING GATES /R0 10/11/2017

Operating Instructions Type MPT 53

HIGH SPEED SLIDING GATE OPENER

User Manual Digital Water Level Indicator for rain water storage tanks

TMT Boxer 24v slider motor installation notes from EasyGate

V200 USER MANUAL SWING GATE OPENER. 100kg 1.5m. 100kg 1.5m

Operating Instructions Pedestrian Turnstile Type MPT 33

SWING GATE OPENER SW300 SERIES

SWING GATE OPENERS 24V DC GEAR MOTOR

PLD880 Stepper motor driver

E-SL 450BD Series INSTRUCTION MANUAL WARNING USER DRIVEN MANUAL*

PW150/PW200 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR

Typical Installation Schematic

CHECKLIST & COMPONENTS

INSTALLER S MANUAL FOR THE AHT TAIL LIFT

Porte 150 Users Manual Swing Gate Opener 24V DC

INSTALLER S MANUAL FOR THE AHT TAIL LIFT

Installation and Maintenancee Manual

MBM6 - Barrier. Installer and User s manual

NOVATEK-ELECTRO LTD Research-and-Manufacture Company Voltage Stabilizer Legat-15

F ERNI K I T THE FERNI-S KIT CONSISTS OF:

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC) WARNINGS FOR THE INSTALLER

LINCE 300/400/600. User s and Intaller s manual

INSPECTIONS AND MAINTENANCE

Owner s Manual. Model 9300 Vehicular Slide Gate Operator

PROJECTOR LIFT MODEL SIH-300 INSTALLATION MANUAL

AeroVironment Universal Solar Pump Controllers

SECTIONAL AND TILTING DOOR OPENER INSTALLATION INSTRUCTIONS AND USER GUIDE. Comfort 800E/1000E

Electro-Mechanical Swing Operator. Table of Contents

SINUS K 13. ACCESSORIES Braking resistors APPLICATION TABLES 78/160 INSTALLATION INSTRUCTIONS

VER KIT. Installation Instructions TECHNICAL HELPLINE

The Powermatic User Guide Test Sieve Shaker

24 V ENCODER SAFE VERSATILE SETTING. Ditec Qik Automatic barriers for passages up to 7.6 m.

Transcription:

Installation and operation manual for BARRIER-5000

Contents 2 Package...3 3 Safety rules...3 4 General information...3 4.1. Technical characteristics...3 5 Mechanical mounting...4 6 Road gate installation...5 6.1 Boom installation...5 6.2 Boom extreme position adjustment...5 7 Connection of electrical wires...6 7.1. Control unit connection...6 7.2 Connection of accessories...6 8 Recording of remote control units...9 9 Slowdown setting...9 9.1. before closed position...9 9.1 before open position...9 10 Release operation...10 11 Maintenance...10 12 Diagnostics...10 2 Installation and operation manual for BARRIER-5000

Technical characteristics 2. Package After receiving of the road gate it must be unpacked and examined to make sure, that it is not damaged. If any damages are discovered, please, contact the supplier. Standard package includes: Title Quantity Quantity 1 Cabinet with integral control unit 1 pc 2 Anchor bolts 4 pc 3 Boom fastening panel 1 pc 4 Boom (5 m) 1 pc 5 Key-switch 1 pc 6 User manual 1 pc 7 Photocells 1 pair 8 Signal lamp 1 pc 3. Safety rules Read carefully these directions. Installation and putting into operation of the road gate must be carried out by the qualified workers. Check for compliance of the supply mains characteristics with the requirements specified in the present directions. Do keep children away from the opening key to avoid unintended move of the boom. Do not let children play with automatic system. Do not go/drive under the road gate while opening or closing it. Do not restrict move of the road gate. Installation, adjustment and repair must be carried out at only when the road gate is de-energized. Safety requirements must be observed when displacing the equipment. All metal elements of the road gate must be grounded. Make certain, that the boom of the road gate is balanced properly: it must keep the position it was put in. In case of break the road gate should be unblocked, then you should wait until the specialists arrive. Use the road gate for its direct purpose only, any other usage is forbidden. The company «DoorHan» shall be not responsible for possible injuries and damage to people, animals and things in case of misuse of the equipment and/or use of an unauthorized modification. 4. General information Road gate BARRIER-5000 is an ideal barrier to control automobile access to the territory with average and high traffic capacity and passage width up to 5 m. The cabinet encloses the motor, reduction gear, boom fastening unit, balancing mechanism, magnetic end switches and control board in a separate casing. The boom is made of an aluminium profile with red light-reflectors, which are easy to see in the dark. The system ensures fixation of the boom in any position, that's why manual opening is possible only if the system is released. The signal lamp is blinking during moving of the boom. Road gates BARRIER-5000 are designed with a glance to the Russian conditions and have the following advantages: Extended working temperature range -20..+55 0 С; Extended supply voltage range; Dust protection and moisture protection grade IP44; Quick going into operation; Usable and durable construction of the release; Special servicing is not required; Easy electrical circuit. This directions contain all necessary information on installation of the equipment and its operation. We recommend you to use original spare parts and accessories only for installation and further operation of the equipment. 4.1 Technical characteristics Maximum boom length, m 5 Motor rotation speed 1400 Maximum opening time, sec 6 Power consumption, W 220 Supply voltage 220V, 50Hz Thermal protection 120 С Boom type rigid Working temperature range -40..+55 С Use intensity (at 20 С) 70% Capacity, W 220 Overall dimensions LхWхD, mm 270х1015х140 Protection class IP54 3 Installation and operation manual for BARRIER-5000 3

Mechanical mounting 5. Mechanical mounting 5.1 Cable laying scheme 1 Road gate BARRIER-5000 2 Photocells 3 Control button 4 Signal lamp 5 External receiver 1) For laying of the cable use rigid or/and flexible protective tubes. 2) Lay power cable 230V separately from signal cables to avoid pickups and disturbances 5.2 Overall dimensions 160mm 95mm 240mm 340mm min 70mm 6. Road gate installation Follow the directions given below to install the road gate properly: Enter the guarded territory and choose the place for the gate road cabinet. Make sure, that the boom has no restrictions along the whole its travel (i.e. tree branches) and is at a minimum distance of 2 m from the overhead transmission lines. If the case if the road gate does not have protection against accidental damage caused by passing-by automobiles, install an additional protection means, if it is possible. The cabinet must be installed on the concrete surface. If the base is not enough strong, make a foundation pit and concrete it. Before concreting the foundation pit must be reinforced and protective tubes (corrugated tubes) for laying of power and supply cables must be laid. Installation must be carried out only after complete concrete congelation. The ground in the place of the gate road installation must be stable. If it is not stable enough, increase the depth of the foundation pit according to the recommendations of the specialists. There must not be any pipes and/or electric cables on the place of foundation pit. Direct the cabinet as it should, level it, using the building level, mark and drill holes for anchor bolts. Install the cabinet and tighten the anchor bolt nuts as shown in the picture. 4 Installation and operation manual for BARRIER-5000

Boom installation Cabinet Anchor bolts (4-M16) Concrete Mounting base Nut 6.1 Boom installation Remove the cabinet casing panel. Direct the boom profile in accordance with opening direction and insert it in the U-shaped fastening bracket. Put on the boom the second U-shaped bracket (as shown in the picture). Place and fix 4 fastening brackets. Install and adjust the balancing springs using tension bolt, so that the boom remains motionless in any position when the operator is released. Resume the normal operation, having blocked the release. 6.2 Boom extreme position adjustment In case if the boom does not reach vertical or horizontal positons adjust its position pull rod 2, which is located inside of the cabinet. Loosen nuts 1. Rotate the pull rod 2 counter-clockwise in order to lift the boom. In order to lower it, rotate the pull rod clockwise. Tighten nuts 1 in the required position. Check vertical and horizontal positions of the boom. If required repeat adjustment. 1 2 5 Installation and operation manual for BARRIER-5000 5

Connection of electrical wires 7. Connection of electrical wires 7.1 Control unit connection The wires in the cable must be protected against contact with any rough and sharp parts. Connect the control unit to the terminal block, located inside if the road gate cabinet. Motor U blue V red W white OP red End switch COM green/yellow CL 7.2 Connection of accessories TF1 Radio Sw1 F1 F2 TMR ACL FRC Photocells Signal lamp Power supply transformer Radio receiver speed connector Dip-switches Fuse 2,5 A Fuse 0,5 A Working time adjustment Autoclose pause adjustment Force adjustment 1 pair of photocells Lamp 7.2.2Control board connectors description ~220 (N, L, PE) Power supply Motor (N, L1, L2) Lamp Motor connection Signal Lamp connection "-" Negative for acessories (24 V), 600 mа "+24V" Sw Op Sw Cl EMRG Ph Op Ph Cl Ped Start 7.2.3 Control board leds description Positive for acessories (24 V), 600 mа Open limit switch (NC) Close limit switch (NC) Emergency stop (NC) Open photocells (NC) Close photocells (NC) Pedestrian opening impulse contact (Dip2 is on) (NO) Full opening impulse contact (NO) Led purpose on off PWR Power Power supplied not supplied A Overloading of maximum current Overload current ok current B Overloading of fixed current Overload current ok current ST START impulse activated inactive PED PED impulse activated inactive Ph1 Close photocells disengaged engaged Ph2 Open photocells disengaged engaged STOP STOP command inactive activated Sw1 Close limit switch disengaged engaged Sw2 Open limit switch disengaged engaged The condition of lightemitting diodes at the collars which are on the average position at rest, is allocated by a bold type. 6 Installation and operation manual for BARRIER-5000

electric connections 8. Electric connections The description of sockets of electric connections. ~220 (N, L, PE) the socket on the block serves for connection to the block of pressure of a food PE: earth connection N: a Food (neutral) L: a Food (phase) MOTOR (N, L1, L2) the socket on the block serves for connection to the electric motor block LAMP the socket on the block serves for connection of an alarm lamp 230V, max. 40Wт. Works at any movement of a cloth of gate. The lamp blinks with the period = 0.5-1 seconds Further contacts of the low-voltage socket intended for connection of accessories are described. 1. START a command Complete opening (N.O.) Short circuit of contacts of the system connected to this plug, leads to operation of the block of management on complete opening and-or closing of gate (the exact logic of work depends on switch Dip1 position). Dip1 - off. Commands in a cycle mode - Open-Stop-Close-Stop are produced. Dip1 - on. Commands in a mode - Open-Close-Stop-Open (at the opening the stop is not provided) are produced After the first inclusion of an electricity the first command Start leads to movement of gate on opening. If from the first command Start of a collar have started to move on closing, it is necessary to change position of switch Dip3 answering for an opening direction. Command Start is perceived by the management block through the period of time equal ~1-2 sec after its previous receipt on an input of the block. For connection of several systems, it is necessary normally opened NO. Contacts of these systems to connect in parallel. 2. Ped - command Pedestrian (1 meter opening) (N.O.) Dip2 - off. Command Ped leads to opening of gate approximately on 1 m. Repeated command Ped leads to closing of gate. If after a command Ped command Start follows, the management block produces a command on complete opening of gate. Command Ped at Dip2-off is fulfilled Only in the closed position of gate, and as at its repeated giving on an input after opening on 1м. Dip2 - on. Separate management of a drive is realised, i.e. Command Start opens gate, Ped - closes. For connection of several systems, it is necessary normally opened NO Contacts of these systems to connect in parallel. 3. SW OP / SW CL - signals from trailer switches of extreme positions of a cloth of gate. Operation (contact disconnection) концевика SW OP / SW CL means that the cloth of gate is in extreme opened / the closed Position and the further movement in the same direction is forbidden. 4. Photo Cl - contacts of connection of safety controls on closing (N.C.). Appointment of the given connections - protection of a cloth of gate at the close. Operation of systems leads to immediate reversive movement of a cloth of gate before complete opening. Operation of the systems connected to these plugs, does not render any influence on work during opening of gate. If gate are opened also the gauges connected to given plugs, have worked, it will prevent movement of gate on closing. For connection of several systems with Н.З. Contacts, it is necessary to connect contacts of these systems consistently. The note: If no systems are connected to the given plugs, it is necessary to establish a crosspiece between Contact plugs Ph CL and - (fig. see). 5. Photo Op - contacts of connection of safety controls on opening (N.C.). Appointment of the given connections - protection of a cloth of gate at opening. Operation of systems leads to an immediate stop of movement. Operation of the systems connected to these plugs, does not render any influence on work in a lock-up of gate. If gate are closed also the gauges connected to given plugs, have worked, it will prevent movement of gate on opening. For connection of several systems with Н.З. Contacts, It is necessary to connect contacts of these systems consistently. The note: If no systems are connected to the given plugs, it is necessary to establish a crosspiece between the contact Plugs Ph Op and - (fig. see). 6. EMRG contact for connection of systems of an emergency stop (N.C.). Appointment of the given connections - protection of a cloth of gate At the close and opening. Any logic of work of the block of management on a signal from these systems in the course of opening and closing of gate provides an immediate stop of movement of gate. If gate are at rest and the gauges connected to given plugs, have worked, it will prevent any movement of gate. For connection of several systems with Н.З. Contacts, it is necessary to connect contacts of these systems consistently. The note: If no systems are connected to the given plugs, it is necessary to establish a crosspiece between the contact Plugs EMRG (the Fig. see). 24V DC - plugs of an exit from the transformer of a food 24 In a direct current, макс. Load 600 ма. ATTENTION: At change of position of DIP-switches or mechanical regulators it is necessary to switch off and again to include pressure of a food of a drive. Otherwise change of options will not occur. 7 Installation and operation manual for BARRIER-5000 7

electric connections 9.2 Description Dip - switches Dip1 - The mode of operation. At switched off Dip1 during opening of gate command Start is not perceived (On/Off) Dip2 - Separate management. At included Dip2 separate management at which the system connected to plug Start sends a command on opening, and the system connected to plug Ped - a command on closing of gate (On/Off) is realised. Dip3 - A direction of opening of a drive. Included Dip3 corresponds to position of a drive to the right of an aperture, switched off Dip3 - a drive to the left of an aperture. Dip4 - Reserve. It is not used. 9.3 Description of mechanical regulators TMR - adjustment of an operating time of the engine. It is used in case of work of a drive without trailer switches. The operating time is regulated in the range from 0 to 100 seconds Extreme right position of an arrow corresponds to the maximum operating time. ACL - adjustment of time of a pause before automatic closing of gate. Pause time is regulated in the range from 0 to 70 seconds In extreme left position of a regulator function of automatic closing switched off. FRC - adjustment of traction effort of a drive (installation of the maximum current of consumption). In extreme right position of a regulator the effort of a drive has a peak figure, and the drive works at full capacity it (is not recommended). 9.4 Automatic closing Automatic closing of a drive is adjusted by means of regulator ACL. For this purpose he is necessary for establishing in any position, Distinct from the extreme left. At regulator turn to the right pause time before automatic closing increases. 9.5 Check of connection of the engine red blue green Check up, that the engine has been connected, as It is shown in drawing. capacitor Attention: Before the beginning of work with a management payment always disconnect a food. Always lay power cables Separately from the alarm. For reduction of the induced noise use a cable with shielded braid. Wires in cables should be protected from contact to any rough and sharp details. Opening photocells connection If you use photocells (DoorHan) set jumper in NC Radio Closing photocells connection If you use photocells (DoorHan) set jumper in NC black black red Capacitor jumpers green blue red limit switches Key switch 8 Installation and operation manual for BARRIER-5000

Programming 10. Programming 10.1 Adjustment of Dip-switches At change of position of Dip-switches or mechanical regulators. Stop from impulse command than moving YES NO Separate control Start opens, Ped - closes YES NO Motor position near the gate Right Left Type of limit switches It is necessary to switch off and again to include the drive power supply. Otherwise change of options will not occur. 8. Recording of remote controllers Setting of control with radio channel of remote controllers DoorHan: 1. Before programming you can clean the memory of the receiver, erasing all former codes. (it is recommended by first setting) Turn on the power supply and hold down record key for 10 sec. The indicator «а» will be blinking for 10 sec, then it will become dim and in 2 sec. it will blink twice to confirm erasing of the former codes. 2. In order to record the code of the remote controller hold down for 3 sec the record key. The read indicator «а»should blink. Release the key. While the red indicator is blinking, hold down for 10 sec the selected key on the remote controller (the key, that you want to control the unit). Hold down the key on the trinket until the red indicator «а» lights for 2sec and then goes out, to confirm that the remote controller code is stored in the memory of the receiver. 3. To make setting of several Для настройки нескольких пультов повторите запись кода для других пультов. You can make setting of 65 remote control units. If the receiver not receives the command in 10 sec, it exits the waiting mode automatically. After the control unit is disconnected from the mains, all programmed data are stored. 9. Slowdown adjustment 9.1 Slowdown before closed position Make sure, that the barrier is fixed rigidly, shift the boom at angle of about 15 degrees to the horizontal. Loosen the nut of the slowdown adjustment screw. (See pic.) Move the screw in the slit until the end switch is activated (control activation using the indicator on the control unit). Fix the screw in the slit, having tightened the fastening nut. Lift and sink the boom, to make certain, that the slowdown end switch works properly. 9.2 Slowdown before opened position Make sure, that the barrier is fixed rigidly, shift the boom at angle of about 15 degrees to the vertical. Loosen the nut of the slowdown adjustment screw. (See pic.) Move the screw in the slit until the end switch is activated (control activation using the indicator on the control unit). Fix the screw in the slit, having tightened the fastening nut. Lift and sink the boom, to make certain, that the slowdown end switch works properly. Note: After slowdown points have been adjusted, make sure, that the end switches work properly: after the end switches snap into action one of the indicator on the control unit must light. If an indicator does not light, make adjustment once more. In case if the boom slowdowns but does not reach the extreme position, move the screw so, that the end switch activation occurs at the moment, when the boom is closer to the extreme position. deceleration adjustment nuts 9 Installation and operation manual for BARRIER-5000 9

Release operation 10. Release operation Use the lever of the integral release to release the barrier After release is completed, the boom can be opened and closed manually. In order to lift or to sink the boom if case of power failure you should do the following: Turn the release lever (see pic.) clockwise up the stop. You can lift or sink the boom by hand. In order to enter automatic control mode of the barrier you should do the following: Turn the release lever in the mid-position. Lift and sink the boom using the operator. release lever 11. Maintenance Make sure, that the boom is fixed and balanced well. Check system unit and safety devices not less than once in 6 months. Maintenance of the road gate must be carried out by the qualified specialists. Keep the road gate clean. The manufacturer reserves the right to make alterations and modifications of the construction without preliminary notice. The present directions describes installation and adjustment operations of the road gate BARRIER-5000. Following the recommendations on operation, maintenance of the road gate as well as installation operation sequence of the operator and the door given in the Directions will ensure long life of the equipment and reduce the possibility of accidents during installation and operation of the door. Observe accident prevention rules while installation and operation. In case of loosing of the present Directions you may request for its duplicate to the following address: 36 Moghaiskoye shosse, Moscow 121354 or e-mail: info@doorhan.ru. The manufacturer (DoorHan) does not handle direct control of installation, maintenance and operation of the doors and the automatics and shall not be responsible for safety of installation, maintenance and operation of the doors, road gates and the automatics. Contents of the directions shall not be basis for any claim. 12. Diagnostics Failure Possible reason Repair The road gate does not work. After the release was used, the road gate does not work by pushing of control keys or remote controllers. Electric power is disconnected. Boom movement is restricted. Bad connection of electric wires. The gate road is released. Return in the starting position was not executed. Make sure, that electric power is on. Remove the restriction. Check wires connection. Engage the road gate. Turm the release lever in midposition (refer to Release operation ) Sudden stop of the road gate. Force protection is activated. Adjust the road gate force. The boom lifts or sinks in jerks or there is sudden stop of the boom. The boom is not balanced. Adjust the balancing spring. The boom does not open or close in full. Wrong adjustment of the end switches. Adjust the end switches. 10 Installation and operation manual for BARRIER-5000

NOTES 11 Installation and operation manual for BARRIER-5000 11

The company DoorHan thanks you for buying our products. We hope you will be satisfied with the quality of our product. If you need any further information about purchasing, distribution and maintenance, contact our regional agents or refer to our central office to the following address: Russia, 143002, Moscovskaya oblast, Odintsovskiy r-n, s. Akulovo, ul.novaya, 120. Tel: +7(495)933-2400, 981-1133 E-mail: Info@doorhan.com www.doorhan.com