product manual H-1240 & H F Electric Penetrometer with Digital Automatic Timer

Similar documents
product manual H-4156M CBR-Specific Load Frame

product manual H-3620, H-3624, H-3625 Flow Table with Mold

product manual H-2966B H-2966B Production, Cylinder End Grinder

Penetration. Test Methods

product manual H-3860D H-3860D_man_0816 Los Angeles Abrasion Machine

ASTM D4. Bitumen Content Qty. Model Description. Related Standards: ASTM D370, E177

ASTM D4. Bitumen Content Qty. Model Description. Related Standards: ASTM D370, E177

Operating and Maintenance Instructions

Pneumatic Power Valves Series 75/76 Manual, Mechanical, Pneumatic and Electric Valves

DISCONTINUED VERSION Parts listed in this catalog may no longer be available. ILLUSTRATED PARTS CATALOG BUNN-O-MATIC CORPORATION

Toshin-Cho Itabashi-ku Tokyo, Japan Tel Fax /06

B SERIES. Bulletin B-2017

OPERATION MANUAL TWE-375 CAPACITOR DISCHARGE WELDER

Bulletin H-Tech 03 High Pressure Valves Series H

OPERATION MANUAL. Model TWP-2. Toll free customer support:

OPERATION MANUAL. TWE Pin Welder. Model TWP-2 TRU WELD EQUIPMENT COMPANY 6400 N. HONEYTOWN ROAD SMITHVILLE, OHIO (330) Revision 2.

Switches. Common Used Terminology:

MATERIAL THICKNESS GAUGES

Installation, Operation & Maintenance Manual Control Panels for Automatic Self-Cleaning Strainers Model 596 and Model 2596

Mini-Trim Switches. Typical Dimensions. Mini-Trim Toggles. 2-way, 4-way, 4-way plus pushbutton, and 8-way toggle switches

RT404-FLEX II ROTARY TABLE OPERATING MANUAL

PACIFIC Recumbent Height-Adjustable Bath System Parts Breakdown and Assembly Manual

ML4330 SIEVE SHAKER MANUAL

Precision Radial Arm Drills

Meinzer II TM. Testing Sieve Shaker

Model 35 PARTS MANUAL

Dial Indicator. SERIES 2 Standard Type, 0.01mm Resolution

Kuhnke Technical Data. Contact Details

instructions ZCM ZCM START International 4270 Airborn Dr. Addison, TX 75001, USA Tel Fax

INSTRUCTIONS. Owner's Manual. Ionizing Air Nozzles Models AN-2 and AN-6

Kuhnke Technical Data. Contact Details

ZICO 2070PM1 REV Page 1

Geopump Peristaltic Pump Installation and Operation Manual

Instruction Manual for the Revolutionary Science RS-102 RevSpin Microcentrifuge

ALLENAIR ROTARY INDEX TABLES

Rocker Lever Assembly

THERMOMETER SPECIFICATIONS

CEMENT TEST EQUIPMENTS

Allied Multiprep System

DEMA 258BD-200C and 258BT-200C DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET

Dial Gauges. Swiss style precision gear module design, accurate display, hardened aluminum alloy housing, assuring durability and reliability.

MPT-250B SPECIFICATIONS AND OPERATING INSTRUCTIONS

RESOURCE GUIDE. P r o d u c t M a n u a l. START International

MICRO WELD MODEL AUF-8 HEAVY DUTY FERROUS BUTT WELDERS MICRO PRODUCTS COMPANY SERVICE MANUAL

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

OPERATING INSTRUCTIONS BULLETIN MODEL DA750 March MAGNETIC INSPECTION UNIT

Camshaft Degree Kit for Ford 5.0L 4V Coyote #4943

SERVICE SADDLES & Cambridge Brass Inc. 140 Orion Place, Cambridge, Ontario, N1R 5V1, Canada

DESCRIPTION. 10" Square Valve 10" Valve for United Plastics Tank Valve Handle-Complete Assembly Auxilliary Handle Lock less Hardware (see page 12)

Make sure the rail is clamped square as shown. Start at the front, and place the first clamp approx 6 to 9 inches back.

DISCONTINUED VERSION Parts listed in this catalog may no longer be available. ILLUSTRATED PARTS CATALOG

INSTRUCTION MANUAL. Series PROCUNIER SAFETY CHUCK CO. (Serial Nos. B4870 and higher. (Serial Nos. B9230 and higher

OWNER S MANUAL & WARRANTY INFORMATION IMPORTANT SAFETY INFORMATION, SAVE THESE INSTRUCTIONS

INDUSTRIAL WIRE FEEDERS FLEX FEED 74 HT, FLEX FEED 84 AND POWER FEED 84

OPERATOR S MANUAL ACE - P100

A Tradition of Competence

Evo. Suspension Rollator. OWNERS HANDBOOK. Product Code: WA01056

F SERIES GEAR PUMP. 2 Muncie Power Products, Inc Muncie Power Products, Inc.

HTR-202 INSTRUCTION MANUAL. Portable Digital Height Rod. Befour, Inc. 102 Progress Drive Saukville, WI 53080

Instruction Manual for the Revolutionary Science RS-200 RevSpin Microcentrifuge

DIMENSIONS. Oil Capacity = 14.6 oz Maximum Fluid Temperature = 140 F Inlet Thread = 1/2 F Discharge Thread = 3/8 F

instruction ZCM 100 ZCM 200 START International 4270 Airborn Dr. Addison, TX 75001, USA Tel Fax

Bimba Metric Flow Controls: FCPM Series M5 Port Mounted Flow Control Valves For M5 port, FCPM-1-Q4-L 4mm OD tubing 2mm ID tubing For M5 port, 4mm OD t

3. Operating instructions: Minor 200

Owner s Manual and Warranty Information

MPT-200A SPECIFICATIONS AND OPERATING INSTRUCTIONS

ELECTRONIC FIREPLACE DAMPER

AQT-275 SERIES SERVICE MANUAL CONTROL VALVES

PVC Stargrip series 4000 Mechanical Joint Wedge Action Restraint for Plastic Pressure Pipe

OPERATOR S MANUAL. TW-i SERIES. Capacitor Discharge Stud Welder. MODELS: TW-i 250 TW-i 250CP TW-i 321 TW-i 375

table of contents Switches J 1 SECTION SECTION J Quick Guide to Switches... J2-J3

Loctite Spray Valve Controller Part Number EQUIPMENT Operation Manual

PVC Stargrip series 4000 Mechanical Joint Wedge Action Restraint for Plastic Pressure Pipe

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

VL Series. General Purpose Compact Limit Switches. Sensing and Control

onlinecomponents.com VL Series General Purpose Compact Limit Switches Sensing and Control

PFM6 Digital Portable Hydraulic Tester

brands, the company s products are recognized for their quality, reliability and technical innovation.

XMV 3400 RPM D VERSION 1 WITH GAS ENGINE FLANGE DIMENSIONS

OPERATION MANUAL MODEL MODEL MODEL MODEL MODEL NON-CONDUCTIVE ARTICULATING FIBERSCOPE INSTRUMENT TECHNOLOGY, INC.

IV STANDS. Assembly, Usage and Maintenance INSTRUCTION MANUAL

OPERATING MANUAL. Cole-Parmer Stir-Pak General-Purpose Laboratory Mixer. Model Number General-Purpose Laboratory Mixer System

Twin-Beam Spotlight 3,000,000 Power Series Corded Cordless Rechargeable

Torque Test Stands Series TS MODELS TST / TSTH & TSTM / TSTMH. User s Guide

LARGE DIAMETER VALVES

Installation Instructions for Pressure Balancing Valve Set with Volume Control. Limited Lifetime Faucet Warranty

Pressure Controller. Cataloge K Code Characteristics Index. K00-2 Pressure Controller Brief Introduction

Escort Stair Lift. Owner's Manual

Electronic Timer Drain and Filter Ball Valves. Operating Instructions Manual

IONIZATION SOLUTIONS

Warner Electric UNIBRAKE Motor Brakes

Owner s Manual and Warranty Information

High Capacity Battery Charger

L-K INDUSTRIES BENCHMARK S MANUAL

Sanandres. Tri-Walker. OWNERS HANDBOOK. Product Code: WA02017

Model LA 4400 Time Delay OFF Controller

FULL HEIGHT ALUMINUM TURNSTILE DOUBLE UNIT AT-FAL SERIES I N STALLATION AND O P E RATING I N STRUCTIONS

Techcon Systems TS6500 CIM Automatic Techkit Mixer

MICRO WELD MODEL AD 6-10 HEAVY DUTY NON-FERROUS BUTT WELDERS MICRO PRODUCTS COMPANY SERVICE MANUAL

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) MODEL C ELECTRIC HYDRAULIC PUMP

Transcription:

07.09 product manual H-1240 & H-1240.4F Electric Penetrometer with Digital Automatic Timer

Introduction The Humboldt Electric Automatic Penetrometer is of rugged construction, but requires careful handling to safeguard its accuracy. Keep the instrument clean at all times especially the drop and indicator plungers, which constitute the spindle assembly. Use denatured alcohol as the cleaner for these surfaces. For complete test procedure(s), refer to the following specifications: ASTM D5, D217, D937, D1168, D1321, D1403, D1831, and AASHTO T49. Installation 1. Level the instrument carefully by means of the leveling screws on the base, sighting the spirit level from above, in order to obtain accurate alignment. After the instrument has been leveled, avoid shifting its location. 2. Position the height of the supporting casting by turning the knurled travel nut on the main support post and then tighten the black knob. 3. If additional weights are used, these should be taken from the side post and set on the end of the plunger (opposite end of the needle chuck). 4. Insert penetrating needle or cone into chuck and tighten the chuck screw. Instruction As supplied by Humboldt the unit is programmed to provide a solenoid actuation period (plunger release) of 5 seconds. The panel-mounted, electronic timer uses 120 VAC, 50/60 Hz. In order to use 240 VAC, a step-down transformer or converter suitable for digital circuits is required. The H-1240.4F is supplied with an H-1042 transformer for this purpose and is plug compatible with the penetrometer cap-plug, but requires the input line cord to the transformer to be wired for local service. For further timer information refer to the ATC Model 365B Long Range Timer Instructions. Operation 1. Holding the plunger with one hand, squeeze the lever on the front of the support casting with the other to allow raising the plunger & needle to clear the sample. Flip the toggle switch on the front panel to the up position and pre-select the specified time of penetration by turning the knobs on the timer bezel. 2. To conduct a test set the needle, cone or micro-cone on the sample surface. When ready to begin, press the red pushbutton on the front panel to release the plunger for the pre-selected amount time. The timercontrolled electromagnet will immediately release the plunger and after the preselected time interval will re-grip it to stop the test. 3. Measure the travel of the plunger assembly by lowering the dial indicator rod to contact the plunger and observing the dial reading.

4. To reset for the next test, the front panel toggle switch must first be flipped to the down position, then the above sequence can be repeated. CAUTION: Keep hands, clothing and other objects away from moving parts when the machine is in operation. Drawing H-1240

Penetration Needles and Cones Application Specification Model Description Bituminous materials Waxes with 250 or less penetration Battery paste ASTM D5; AASHTO T49, IP49; ASA Std., A37.1; Fed Spec. SS.R. 406C, Meth. 214.01 ASTM D1321 H-1280 H-1300 H-1302 H-1290 H-1310 H-1317 N/A H-1255 Standard hardened stainless steel needle, 40-45mm exposed needle length. Wt. 2.5g. Same as H-1280. Certified to ASTM accuracy by independent laboratory. Wt. 2.5g. Same as H-1290. Certified to ASTM accuracy by independent laboratory. Wt. 2.5g. Long hardened stainless steel needle, 50-55mm exposed needle length. Wt. 2.5g. Hardened stainless steel wax penetration needles with tapered point, blunt tip of truncated cone. Ferrule is approx. 3.2mm dia. Wt. 2.5g. Same as H-1310. Certified to ASTM accuracy by independent laboratory. Hardened stainless steel tip with special plunger. Total wt. 60g ±.050g. Joint sealant for asphalt & concrete pavements Grease-testing penetrometers For all 90 cones ASTM D5329 H-1320 ASTM D217, D937 ASA Std. Z11.3 H-2520 H-2522 H-2525 Grease-testing penetrometers ASTM D2884 H-2524 Food products and paste paints (shortenings, margarine, butter, etc.) Measuring firmness of solid and plasticized fats (i.e., recovery of used grease) Small obtainable samples U.S. Dept. of Agriculture H-2529 AOCS Cc 16-60 H-1270 ASTM D1403 H-2519 Resilience ball penetration tool. Total wt. 27.5g. Hollow 90 brass cone, highly polished stainless steel tip. Removable nut and stem. Wt. 102.5g. Same as H-2520, completely made of stainless steel. Wt. 102.5g. Stainless steel replacement tip, nut and stem. Magnesium cone and plunger, same dim. as H-2520. Total wt. cone and plunger 30.0g. Aluminum. Same dimension as H-2520. Total wt. 35g. 10 aluminum cone, 3.2mm ferrule, 0.8mm stainless steel blunt tip. Overall length 106mm. Wt. 45g. 1/4 scale. (Not considered a substitute for full-size cone specified in ASTM D217.) Wt. 9.38g.

Penetration Needles and Cones H-1280 H-1290 H-1300 H-1302 H-1310 H-1317 H-1255 H-1320 H-1270 H-2519 H-2520 H-2522 H-2529

Warranty Humboldt Mfg. Co. warrants its products to be free from defects in material or workmanship. The exclusive remedy for this warranty is Humboldt Mfg. Co., factory replacement of any part or parts of such product, for the warranty of this product please refer to Humboldt Mfg. Co. catalog on Terms and Conditions of Sale. The purchaser is responsible for the transportation charges. Humboldt Mfg. Co. shall not be responsible under this warranty if the goods have been improperly maintained, installed, operated or the goods have been altered or modified so as to adversely affect the operation, use performance or durability or so as to change their intended use. The Humboldt Mfg. Co. liability under the warranty contained in this clause is limited to the repair or replacement of defective goods and making good, defective workmanship. Humboldt Mfg. Co. 3801 North 25th Avenue Schiller Park, Illinois 60176 U.S.A. U.S.A. Toll Free: 1.800.544.7220 Voice: 1.708.456.6300 Fax: 1.708.456.0137 Email: hmc@humboldtmfg.com Testing Equipment for Construction Materials HUMBOLDT www.humboldtmfg.com