High Performance LED Lighting Changing the way the world experiences light.
Anthony Masters First Congregational Church of Los Angeles Lighting Design By First Circle Design, LLC Anthony Masters First Congregational Church of Los Angeles Lighting Design By First Circle Design, LLC Anthony Masters First Congregational Church of Los Angeles Lighting Design By First Circle Design, LLC Bridging Science with the Architecture of Light Perhaps no product in the industry better demonstrates Lighting Science than the DEFINITY LED lamp line. Boasting one of the broadest arrays of ENERGY STAR qualified LED lamps in the industry, the ability to optimize LED performance while never losing sight of providing superior lighting effects is the hallmark of DEFINITY. 1 I www.lsgc.com
DEFINITY Performance The performance breakthroughs achieved with the DEFINITY Lamp line are a direct result of an LED system design approach encompassing efficient power supplies, unique thermal solutions, top-tier LED technology, leading edge optical control solutions and rigid binning techniques that result in visually pleasing light sources that seamlessly transition into retrofit applications. WHY CHOOSE DEFINITY? Long life Up to 50,000 hours ENERGY STAR qualified lamps available throughout line to meet utility rebate requirements High CBCP performance with a wide selection of beam patterns High efficacy up to 71 lumens per watt Various beam spreads 10-40 degrees Suitable for wet locations (PAR0, 30, 38 Series) Dimmable (as noted) down to as low as 5% and compatible with a wide array of dimmers Instant-on with no warm up, unlike CFL High color saturation with CRI s up to 85 Extensive range of color temperatures 700K - 5000K Incandescent equivalents up to 10W High efficiency with input power of 6-4W 3-5 year limited warranty RoHS compliant-contains no mercury or lead In most instances, payback in less than a year www.lsgc.com I
The DEFINITY Advantage Full Line Dimmability 1 World class driver designs provide real time monitoring and adaptability to individual dimmers to ensure high efficiency, flicker free performance down to 5% of rated light output. - + Optimized Thermal Management The DEFINITY high efficiency spiral heat-sink design increases surface area and coupled with unique alloys maximizes LED life and improves efficacy. Unlike many LED lamps on the market today, this solution allows Lighting Science to rate many of our LED lamps for enclosed luminaire applications. Environmentally Friendly Unlike CFL s, DEFINITY LED lamps contain no mercury or lead and are RoHS compliant. A true green solution from a true green company. Superior Lighting Quality Featuring CRI s up to 85 in 700-5000 CCT s, DEFINITY lamps provide high color saturation to beautifully highlight and render the environments they illuminate. Unlike other sources, DEFINITY lamps won t cause discoloration or fading of the objects they illuminate. 3 I www.lsgc.com
Sized to Fit All DEFINITY lamps have been sized within ANSI form factors to seamlessly replace their counterparts in retrofit applications. Simply remove, install, save and enjoy. Smooth Beam Optical Control The DEFINITY smooth, uniform light distribution originates from LED mixing and design strategies. When combined with high performance optics, they replicate visible incandescent point sources without the pixilation look of many inferior LED lamp designs. Color Consistency DEFINITY lamps leverage design and LED binning strategies that result in color consistency that is approximately four times better than allowable ANSI standards to assure high quality color performance without variability in application. NAFTA Compliant DEFINITY lamps are fully NAFTA compliant making them eligible for most ARRA projects. Consult specific project requirements as eligibility requirements may vary. NAFTA COMPLIANT This product qualifies as an originating good under the terms of NAFTA. ENERGY STAR Compliance Most utility rebate programs only allow ENERGY STAR qualified lamps to participate in their programs. Lighting Science Group s leadership in lamp design has quickly allowed us to develop one of the industry s largest collection of ENERGY STAR qualified lamps. 1 Consult page 5 for a list of tested compatible dimmers. www.lsgc.com I 4
PAR38 DEFINITY PAR38 & PAR38 Hi-Output FEATURES Dimmable to 5% of light on most dimmers. 1 Up to four unique beam distributions for application flexibility. Suitable for wet locations. 18/4 Watts 80% more efficient than comparable 90/10 Watt Halogen lamps. Maintenance free operation, lasts up to 16 times longer than conventional lighting. Superior thermal management allows for product usage in enclosed luminaires. Centralized optical package provides high quality point source beam versus pixilated designs. RoHS compliant contains no mercury or lead. ANNUAL OVERALL SAVINGS Standard Halogen Maintenance Cost $0 $36 PAR38 Annual Savings $49 $7 PAR38 Savings: $610 Standard Halogen 90W 3,000 hrs Up to 80% energy savings PAR38 18W Up to 50,000 hrs 5 I www.lsgc.com
PAR38 Part Number Beam Angle 5 Lumens CRI CBCP ENERGY STAR 4 DFN 38 NW NFL 10 18W 5 950 85 4099 DFN 38 WW NFL 10 18W 5 840 85 3493 DFN 38 W7 NFL 10 3 18W 5 850 85 3574 DFN 38 CW NFL 10 18W 5 190 67 4711 DFN 38 NW FL 10 18W 40 890 85 1766 DFN 38 WW FL 10 18W 40 850 85 1568 DFN 38 W7 FL 10 18W 40 864 85 1658 DFN 38 CW FL 10 18W 40 109 67 030 DFN 38 NW SP 10 18W 15 950 85 6977 DFN 38 WW SP 10 18W 15 850 85 6055 DFN 38 W7 SP 10 3 18W 15 850 85 6194 DFN 38 CW SP 10 18W 15 190 67 8019 DFN 38 NW NSP 10 18W 10 950 85 1600 DFN 38 WW NSP 10 18W 10 850 85 1100 DFN 38 W7 NSP 10 18W 10 850 85 1100 DFN 38 CW NSP 10 18W 10 190 67 14400 PAR38 Hi-Output Part Number Beam Angle 5 Lumens CRI CBCP Life DFN 38 NW V NFL 10 4W 5 1375 85 5500 50,000 DFN 38 WW V NFL 10 4W 5 1300 85 500 50,000 DFN 38 W7 V NFL 10 4W 5 150 85 5000 50,000 DFN 38 CW V NFL 10 4W 5 1460 67 5900 50,000 DFN 38 NW V FL 10 4W 40 1375 85 500 50,000 DFN 38 WW V FL 10 4W 40 1300 85 400 50,000 DFN 38 W7 V FL 10 4W 40 150 85 50 50,000 DFN 38 CW V FL 10 4W 40 1460 67 700 50,000 DFN 38 NW V SP 10 4W 15 1375 85 9400 50,000 DFN 38 WW V SP 10 4W 15 1300 85 8900 50,000 DFN 38 W7 V SP 10 4W 15 150 85 8500 50,000 DFN 38 CW V SP 10 4W 15 1460 67 10000 50,000 DFN 38 NW V NSP 10 4W 10 1375 85 1800 50,000 DFN 38 WW V NSP 10 4W 10 1300 85 1700 50,000 DFN 38 W7 V NSP 10 4W 10 150 85 16500 50,000 DFN 38 CW V NSP 10 4W 10 1460 67 1900 50,000 NFL: Narrow Flood FL: Flood SP: Spot NSP: Narrow Spot NW: Neutral White WW: Warm White W7: Warm White 700K CW: Cool White CBCP: Center Beam Candle Power ORDERING INFORMATION \\ DFN 38 WW FL 10 Family Product Color (CCT) Light Output Distribution Voltage DFN Definity 38 PAR38 W7 Warm White 700K (leave blank for standard) FL Flood 10 10 Volt WW Warm White 3000K V High Output NFL Narrow Flood 30 30 Volt 6 CERTIFICATIONS NW Neutral White 4000K SP Spot CW Cool White 5000K NSP Narrow Spot 7 ENVIRONMENT MOL: 5.08 19mm Diameter: 4.74 10mm Specifications supplied are nominal. Please refer to the DOE s Lighting Facts Tolerance Guidelines. 1 See dimmer compatibility chart page 5. Savings based on 4000 annual hours of operation, $0.10 average cost per KWH. $40/hr. cost of labor and 15 minutes maintenance time to change lamp. 3 ENERGY STAR rating for DFN 38 W7 NFL 10 & DFN 38 W7 SP 10 = 0K hours. 4 Early Submission ENERGY STAR Life = 5,000 hours (L70 lumen depreciation design criteria = 50,000 hours.) For directional lamps, Energy Star early submission dictates that manufacturers can only claim 5,000 hour life with 3000 hour actual life test data, 6,000 hour LM80 data and in-situ temperature measurements. Once a product has been fully qualified, manufacturers may increase the lifetime of a product by demonstrating full compliance with the ENERGY STAR criteria at the new lifetime with Lumen Maintenance at the minimum required test period. Refer to Energy Star website. 5 Values are nominal. 6 30V utilizes E7 base, otherwise consult factory. 7 Available on V high output only. www.lsgc.com I 6
PAR30 DEFINITY PAR30 & PAR30 Hi-Output FEATURES Dimmable to 5% of light on most dimmers. 1 Up to three unique beam distributions for application flexibility. Suitable for wet locations. 15/18 Watts 80% more efficient than comparable 75/90 Watt Halogen lamp. Maintenance free operation, lasts up to 16 times longer than conventional lighting. Superior thermal management allows for product usage in enclosed luminaires. Centralized optical package provides high quality point source beam versus pixilated designs. RoHS compliant contains no mercury or lead. ANNUAL OVERALL SAVINGS Standard Halogen Maintenance Cost $19 $30 PAR30 Annual Savings $43 $6 PAR30 Savings: $533 Standard Halogen 75W 3,000 hrs Up to 80% energy savings PAR30 15W Up to 50,000 hrs 7 I www.lsgc.com
PAR30 Part Number Beam Angle 4 Lumens CRI CBCP ENERGY STAR 3 DFN 30 NW NFL 10 15W 5 800 85 316 DFN 30 WW NFL 10 15W 5 75 85 3056 DFN 30 W7 NFL 10 15W 5 700 85 81 DFN 30 CW NFL 10 15W 5 943 67 4000 DFN 30 NW FL 10 15W 40 769 85 1476 DFN 30 WW FL 10 15W 40 70 85 1317 DFN 30 W7 FL 10 15W 40 700 85 197 DFN 30 CW FL 10 15W 40 943 67 1950 DFN 30 NW SP 10 15W 15 800 85 504 DFN 30 WW SP 10 15W 15 75 85 4509 DFN 30 W7 SP 10 15W 15 710 85 504 DFN 30 CW SP 10 15W 15 943 67 7600 PAR30 Hi-Output Part Number Beam Angle 4 Lumens CRI CBCP Life DFN 30 NW V NFL 10 18W 5 1000 85 3700 50,000 DFN30 WW V NFL 10 18W 5 950 85 3500 50,000 DFN 30 W7 V NFL 10 18W 5 90 85 3450 50,000 DFN 30 CW V NFL 10 18W 5 1060 67 4000 50,000 DFN 30 NW V FL 10 18W 40 1000 85 1800 50,000 DFN 30 WW V FL 10 18W 40 950 85 1700 50,000 DFN 30 W7 V FL 10 18W 40 90 85 1600 50,000 DFN 30 CW V FL 10 18W 40 1060 67 1950 50,000 DFN 30 NW V SP 10 18W 15 1000 85 7100 50,000 DFN 30 WW V SP 10 18W 15 950 85 6800 50,000 DFN 30 W7 V SP 10 18W 15 90 85 6600 50,000 DFN 30 CW V SP 10 18W 15 1060 67 7600 50,000 NFL: Narrow Flood FL: Flood SP: Spot NW: Neutral White WW: Warm White W7: Warm White 700K CW: Cool White CBCP: Center Beam Candle Power ORDERING INFORMATION \\ DFN 30 WW FL 10 Family Product Color (CCT) Light Output Distribution Voltage DFN Definity 30 PAR30 W7 Warm White 700K (leave blank for standard) FL Flood 10 10 Volt WW Warm White 3000K V High Output NFL Narrow Flood 30 30 Volt 5 NW Neutral White 4000K SP Spot CW Cool White 5000K CERTIFICATIONS ENVIRONMENT MOL: 4.56 115.84mm Diameter: 3.779 96mm Specifications supplied are nominal. Please refer to the DOE s Lighting Facts Tolerance Guidelines. 1 See dimmer compatibility chart page 5. Savings based on 4000 annual hours of operation, $0.10 average cost per KWH. $40/hr. cost of labor and 15 minutes maintenance time to change lamp. 3 Early Submission ENERGY STAR Life = 5,000 hours (L70 lumen depreciation design criteria = 50,000 hours.) For directional lamps, Energy Star early submission dictates that manufacturers can only claim 5,000 hour life with 3000 hour actual life test data, 6,000 hour LM80 data and in-situ temperature measurements. Once a product has been fully qualified, manufacturers may increase the lifetime of a product by demonstrating full compliance with the ENERGY STAR criteria at the new lifetime with Lumen Maintenance at the minimum required test period. Refer to Energy Star website. 4 Values are nominal. 5 30V utilizes E7 base, otherwise consult factory. www.lsgc.com I 8
PAR0 DEFINITY PAR0 & PAR0 Hi-Output FEATURES Dimmable to 5% of light on most dimmers 1 Two unique beam distributions for application flexibility. Suitable for wet locations. 8 Watts 84% more efficient than comparable 50 Watt Halogen lamps. Maintenance free operation, lasts up to 16 times longer than conventional lighting. Superior thermal management allows for product usage in enclosed luminaires. Centralized optical package provides high quality point source beam versus pixilated designs. RoHS compliant contains no mercury or lead. ANNUAL OVERALL SAVINGS Standard Halogen PAR0 Maintenance Cost $1 $ Annual Savings $40 PAR0 Savings: $501 $3 Standard Halogen 50W 3,000 hrs Up to84% energy savings PAR0 8W Up to 50,000 hrs 9 I www.lsgc.com
PAR0 Part Number Beam Angle 4 Lumens CRI CBCP ENERGY STAR 3 DFN 0 NW NFL 10 8W 5 350 85 138 DFN 0 WW NFL 10 8W 5 350 85 1057 DFN 0 W7 NFL 10 8W 5 35 85 1175 DFN 0 CW NFL 10 8W 5 508 67 1797 DFN 0 NW FL 10 8W 40 370 85 714 DFN 0 WW FL 10 8W 40 350 85 650 DFN 0 W7 FL 10 8W 40 310 85 570 DFN 0 CW FL 10 8W 40 508 67 1036 PAR0 Hi-Output Part Number Beam Angle 4 Lumens CRI CBCP Life DFN 0 NW V NFL 10 8W 5 450 85 1450 50,000 DFN 0 WW V NFL 10 8W 5 45 85 1400 50,000 DFN 0 W7 V NFL 10 8W 5 415 85 1350 50,000 DFN 0 CW V NFL 10 8W 5 480 67 1550 50,000 DFN 0 NW V FL 10 8W 40 450 85 900 50,000 DFN 0 WW V FL 10 8W 40 45 85 860 50,000 DFN 0 W7 V FL 10 8W 40 415 85 840 50,000 DFN 0 CW V FL 10 8W 40 480 67 950 50,000 NFL: Narrow Flood FL: Flood NW: Neutral White WW: Warm White W7: Warm White 700K CW: Cool White CBCP: Center Beam Candle Power ORDERING INFORMATION \\ DFN 0 WW FL 10 Family Product Color (CCT) Light Output Distribution Voltage DFN Definity 0 PAR0 W7 Warm White 700K (leave blank for standard) FL Flood 10 10 Volt WW Warm White 3000K V High Output NFL Narrow Flood 30 30 Volt 5 NW Neutral White 4000K CW Cool White 5000K CERTIFICATIONS ENVIRONMENT MOL: 3.4 86mm Diameter:.598 66mm Specifications supplied are nominal. Please refer to the DOE s Lighting Facts Tolerance Guidelines. 1 See dimmer compatibility chart page 5. Savings based on 4000 annual hours of operation, $0.10 average cost per KWH. $40/hr. cost of labor and 15 minutes maintenance time to change lamp. 3 Early Submission ENERGY STAR Life = 5,000 hours (L70 lumen depreciation design criteria = 50,000 hours.) For directional lamps, Energy Star early submission dictates that manufacturers can only claim 5,000 hour life with 3000 hour actual life test data, 6,000 hour LM80 data and in-situ temperature measurements. Once a product has been fully qualified, manufacturers may increase the lifetime of a product by demonstrating full compliance with the ENERGY STAR criteria at the new lifetime with Lumen Maintenance at the minimum required test period. Refer to Energy Star website. 4 Values are nominal. 5 30V utilizes E7 base, otherwise consult factory. www.lsgc.com I 10
BR30 & BR40 DEFINITY BR30 & BR40 FEATURES Dimmable to 5% of light on most dimmers. 1 15/18 watts 80% more efficient than comparable BR incandescent lamps. Maintenance free operation, lasts up to 5 times longer than conventional lighting. Patent pending optical design achieves smooth beam pattern to achieve a warm room filling glow for general illumination applications. RoHS compliant contains no mercury or lead. ANNUAL OVERALL SAVINGS Standard Incandescent Maintenance Cost $6 $30 BR30 Annual Savings $50 $6 BR30 Savings: $65 Standard Incandescent 65-75W,000 hrs Up to 80% energy savings BR30 15W Up to 50,000 hrs 11 I www.lsgc.com
BR30 Part Number Lumens CRI Life DFN BR30 NW 10 15W 844 80 50,000 DFN BR30 WW 10 15W 800 80 50,000 DFN BR30 W7 10 15W 75 80 50,000 DFN BR30 CW 10 15W 895 67 50,000 BR40 Part Number Lumens CRI Life DFN BR40 NW 10 18W 950 80 50,000 DFN BR40 WW 10 18W 900 80 50,000 DFN BR40 W7 10 18W 875 80 50,000 DFN BR40 CW 10 18W 1006 67 50,000 NW: Neutral White WW: Warm White W7: Warm White 700K CW: Cool White ORDERING INFORMATION \\ DFN BR30 WW 10 \\ DFN BR40 WW 10 Family Product Color (CCT) Voltage DFN Definity BR30 BR30 W7 Warm White 700K 10 10 Volt BR40 BR40 WW Warm White 30000K 30 30 Volt 3 NW Neutral White 4000K CW Cool White 5000K CERTIFICATIONS ENVIRONMENT BR30 MOL: 5.375 136.5mm BR40 MOL: 6.565 166.7mm Diameter: 3.8 96mm Diameter: 5 18mm Specifications supplied are nominal. Please refer to the DOE s Lighting Facts Tolerance Guidelines. 1 See dimmer compatibility chart page 5. Savings based on 4000 annual hours of operation, $0.10 average cost per KWH. $40/hr. cost of labor and 15 minutes maintenance time to change lamp. 3 30V utilizes E7 base, otherwise consult factory. www.lsgc.com I 1
PAR16 & GU10 DEFINITY PAR16 & MR16 GU10 FEATURES 6 Watts 80% more efficient than comparable 30 Watt Halogen lamp. Maintenance free operation, lasts up to six times longer than conventional lighting. Two beam distributions. Available from 700-5000K CCT. ANNUAL OVERALL SAVINGS 1 Standard Halogen Maintenance Cost $35 $1 GU10 Annual Savings $45 1 $ GU10 Savings: $390 Standard Halogen 30W 5000 hrs Up to 80% energy savings GU10 6W 30,000 hrs 13 I www.lsgc.com
PAR16 Part Number Beam Angle Lumens CRI CBCP Life 3 DFN 16 NW NFL 10 6W 5 75 85 98 30,000 DFN 16 WW NFL 10 6W 5 95 85 768 30,000 DFN 16 W7 NFL 10 6W 5 50 85 930 30,000 DFN 16 CW NFL 10 6W 5 44 67 1516 30,000 DFN 16 NW FL 10 6W 40 318 85 568 30,000 DFN 16 WW FL 10 6W 40 300 85 584 30,000 DFN 16 W7 FL 10 6W 40 50 85 487 30,000 DFN 16 CW FL 10 6W 40 44 67 860 30,000 MR16 GU10 Part Number Beam Angle Lumens CRI CBCP Life 3 DFN 16 NW NFL 10 GU10 6W 5 345 85 1150 30,000 DFN 16 WW NFL 10 GU10 6W 5 35 85 1100 30,000 DFN 16 W7 NFL 10 GU10 6W 5 315 85 1050 30,000 DFN 16 CW NFL 10 GU10 6W 5 365 67 100 30,000 DFN 16 NW FL 10 GU10 6W 40 345 85 470 30,000 DFN 16 WW FL 10 GU10 6W 40 35 85 450 30,000 DFN 16 W7 FL 10 GU10 6W 40 315 85 435 30,000 DFN 16 CW FL 10 GU10 6W 40 365 67 510 30,000 DFN 16 NW NFL 30 GU10 6W 5 345 85 1150 30,000 DFN 16 WW NFL 30 GU10 6W 5 35 85 1100 30,000 DFN 16 W7 NFL 30 GU10 6W 5 315 85 1050 30,000 DFN 16 CW NFL 30 GU10 6W 5 365 67 100 30,000 DFN 16 NW FL 30 GU10 6W 40 345 85 470 30,000 DFN 16 WW FL 30 GU10 6W 40 35 85 450 30,000 DFN 16 W7 FL 30 GU10 6W 40 315 85 435 30,000 DFN 16 CW FL 30 GU10 6W 40 365 67 510 30,000 NFL: Narrow Flood FL: Flood NW: Neutral White WW: Warm White W7: Warm White 700K CW: Cool White CBCP: Center Beam Candle Power ORDERING INFORMATION \\ DFN 16 WW FL 10 GU10 \\ DFN 16 WW FL 10 Family Product Color (CCT) Distribution Voltage Socket DFN Definity 16 MR16 4 W7 Warm White 700K FL Flood 10 10 Volt GU10 GU10 16 PAR16 4 WW Warm White 3000K NFL Narrow Flood 30 30 Volt 5 (Leave blank for PAR16) NW Neutral White 4000K CW Cool White 5000K CERTIFICATIONS ENVIRONMENT P16 GU10 P16 MOL: 1.94 49.336mm Diameter: 1.97 50.05mm GU10 MOL:. 56.50mm Diameter: 1.97 50.05mm Specifications supplied are nominal. Please refer to the DOE s Lighting Facts Tolerance Guidelines. 1 Savings based on 4000 annual hours of operation, $0.10 average cost per KWH. $40/hr. cost of labor and 15 minutes maintenance time to change lamp. Values are nominal. 3 Three year limited warranty. 4 Non dimmable. 5 30V utilizes E7 base, otherwise consult factory. www.lsgc.com I 14
MR16 DEFINITY MR16 FEATURES 6 Watts 70% more efficient than comparable 0 Watt Halogen lamp. Maintenance free operation, lasts up to seven times longer than conventional lighting. Two beam distributions. Available from 700-5000K CCT. Compatible with a wide array of AC, DC and magnetic or electronic transformers. 1 ANNUAL OVERALL SAVINGS Standard Halogen Maintenance Cost $13 $8 MR16 Annual Savings $18 $ MR16 Savings: $161 Standard Halogen 0W 5000 hrs Up to 70% energy savings MR16 6W 35,000 hrs 15 I www.lsgc.com
MR16 Part Number Beam Angle 3 Lumens CRI CBCP ENERGY STAR 4 DFN 16 NW NFL 6W 5 75 85 98 DFN 16 WW NFL 6W 5 95 85 768 DFN 16 W7 NFL 6W 5 50 85 930 DFN 16 CW NFL 6W 5 44 67 1516 DFN 16 NW FL 6W 40 318 85 568 DFN 16 WW FL 6W 40 300 85 584 DFN 16 W7 FL 6W 40 50 85 487 DFN 16 CW FL 6W 40 44 67 860 NFL: Narrow Flood FL: Flood NW: Neutral White WW: Warm White W7: Warm White 700K CW: Cool White CBCP: Center Beam Candle Power Huntertarian Museum Lighting Design By David Russ, Hunterian Museum at the University of Glasgow ORDERING INFORMATION \\ DFN 16 WW FL Family Product Color (CCT) Distribution DFN Definity 16 MR16 W7 Warm White 700K FL Flood WW Warm White 3000K NFL Narrow Flood NW Neutral White 4000K CW Cool White 5000K CERTIFICATIONS ENVIRONMENT 16 MOL: 1.94 49.336mm Diameter: 1.97 50.05mm Specifications supplied are nominal. Please refer to the DOE s Lighting Facts Tolerance Guidelines. LM79 results based on 1 Volt DC source 1 See transformer compatibility chart page 6. Savings based on 4000 annual hours of operation, $0.10 average cost per KWH. $40/hr. cost of labor and 15 minutes maintenance time to change lamp. 3 Values are nominal. 4 Early Submission ENERGY STAR Life = 5,000 hours (L70 lumen depreciation design criteria = 50,000 hours.) For directional lamps, Energy Star early submission dictates that manufacturers can only claim 5,000 hour life with 3000 hour actual life test data, 6,000 hour LM80 data and in-situ temperature measurements. Once a product has been fully qualified, manufacturers may increase the lifetime of a product by demonstrating full compliance with the ENERGY STAR criteria at the new lifetime with Lumen Maintenance at the minimum required test period. Refer to Energy Star website. www.lsgc.com I 16
A19 Omni-directional DEFINITY A19 FEATURES Dimmable to 5% of light on most dimmers. 1 ENERGY STAR compliant, Omni-directional design 8/ 13.5 Watts 80% more efficient than comparable 40/60 Watt Incandescent lamps. Maintenance free operation, lasts over 50 times longer than conventional lighting. RoHS compliant contains no mercury or lead. ANNUAL OVERALL SAVINGS Standard Incandescent Maintenance Cost A19 $57 $76 $4 Annual Savings $5 A19 Savings: $949 Standard Incandescent 60W 750 hrs Up to 80% energy savings A19 13.5W 50,000 hrs 17 I www.lsgc.com
A19 Part Number Watts Lumens CRI Life DFN 19 NW V1 10 8 450 85 50,000 DFN 19 WW V1 10 8 45 85 50,000 DFN 19 W7 V1 10 8 400 85 50,000 DFN 19 CW V1 10 8 475 67 50,000 DFN 19 NW V 10 13.5 890 85 50,000 DFN 19 WW V 10 13.5 850 85 50,000 DFN 19 W7 V 10 13.5 800 85 50,000 DFN 19 CW V 10 13.5 945 67 50,000 NW: Neutral White WW: Warm White W7: Warm White 700K CW: Cool White ORDERING INFORMATION \\ DFN 19 WW V 10 Family Product Color (CCT) Light Output Voltage DFN Definity 19 A19 W7 Warm White 700K V1 40W Equivalent 10 10 Volt WW Warm White 3000K V 60W Equivalent NW Neutral White 4000K CW Cool White 5000K CERTIFICATIONS ENVIRONMENT MOL: 4.3 86mm Specifications supplied are nominal. Please refer to the DOE s Lighting Facts Tolerance Guidelines. 1 See dimmer compatibility chart page 5. Savings based on 4000 annual hours of operation, $0.10 average cost per KWH. $40/hr. cost of labor and 15 minutes maintenance time to change lamp. 3 Early Submission ENERGY STAR Life = 5,000 hours (L70 lumen depreciation design criteria = 50,000 hours.) For directional lamps, Energy Star early submission dictates that manufacturers can only claim 5,000 hour life with 3000 hour actual life test data, 6,000 hour LM80 data and in-situ temperature measurements. Once a product has been fully qualified, manufacturers may increase the lifetime of a product by demonstrating full compliance with the ENERGY STAR criteria at the new lifetime with Lumen Maintenance at the minimum required test period. Refer to Energy Star website. www.lsgc.com I 18
DFN19 & DFN5 DEFINITY DFN19 & DFN5 FEATURES Dimmable to 5% of light on most dimmers. 1 8 Watts up to 84% more efficient than comparable 50 Watt Incandescent lamp (G5 version). Maintenance free operation, lasts up to 0 times longer than conventional lighting. RoHS compliant contains no mercury or lead. ANNUAL OVERALL SAVINGS Standard Incandescent Maintenance Cost DFN5 $64 $74 $0 Annual Savings $10 DFN5 Savings: $404 Standard Incandescent 50W 750 hrs Up to 84% energy savings DFN5 8W 0,000 hrs 19 I www.lsgc.com
DFN19 Part Number Lumens CRI Life DFN 19 NW 10 8W 460 85 50,000 DFN 19 WW 10 8W 435 85 50,000 DFN 19 W7 10 8W 395 85 50,000 DFN 19 CW 10 8W 570 67 50,000 DFN5 Part Number Lumens CRI ENERGY STAR 3 DFN 5 NW 10 8W 475 85 DFN 5 WW 10 8W 450 85 DFN 5 W7 10 8W 380 85 DFN 5 CW 10 8W 575 67 NW: Neutral White WW: Warm White W7: Warm White 700K CW: Cool White ORDERING INFORMATION \\ DFN 19 WW 10 \\ DFN 5 WW 10 Family Product Color (CCT) Voltage DFN Definity 19 19 W7 Warm White 700K 10 10 Volt 5 G5 WW Warm White 3000K NW Neutral White 4000K CW Cool White 5000K CERTIFICATIONS ENVIRONMENT 19 MOL: 4.3 86mm G5 MOL: 4.68 118.88mm Specifications supplied are nominal. Please refer to the DOE s Lighting Facts Tolerance Guidelines. 1 See dimmer compatibility chart page 5. Savings based on 4000 annual hours of operation, $0.10 average cost per KWH. $40/hr. cost of labor and 15 minutes maintenance time to change lamp. 3 Early Submission ENERGY STAR Life = 15,000 hours (L70 lumen depreciation design criteria = 50,000 hours.) For decorative lamps, Energy Star early submission dictates that manufacturers can only claim 15,000 hour life with 3000 hour actual life test data, 6,000 hour LM80 data and in-situ temperature measurements. Once a product has been fully qualified, manufacturers may increase the lifetime of a product by demonstrating full compliance with the ENERGY STAR criteria at the new lifetime with Lumen Maintenance at the minimum required test period. Refer to Energy Star website. www.lsgc.com I 0
DEFINITY Lamp Range PAR38 PAR38 Hi-Output PAR30 PAR30 Hi-Output Comparable 90W halogen 10W halogen 75W halogen 95W halogen Equivalence 18 4 15 18 Voltage 10 VAC 10 VAC 10 VAC 10 VAC Beam Angle 5 40 15 10 5 40 15 10 5 40 15 5 40 15 Output (lumens) WW 840 850 850 850 WW 1300 1300 1300 1300 WW 75 70 75 WW 950 950 950 W7 850 864 850 850 W7 150 150 150 150 W7 700 700 710 W7 90 90 90 NW 950 890 950 950 NW 1375 1375 1375 1375 NW 800 769 800 NW 1000 1000 1000 CW 190 109 190 190 CW 1460 1460 1460 1460 CW 943 943 943 CW 1060 1060 1060 Center Beam 5 40 15 10 5 40 15 10 5 40 15 5 40 15 Candle Power WW 3493 1568 6055 1100 WW 500 400 8900 1700 WW 3056 1317 4509 WW 3500 1700 6800 (candelas) W7 3574 1658 6194 1100 W7 5000 50 8500 16500 W7 81 197 504 W7 3450 1600 6600 NW 4099 1766 6977 1600 NW 5500 500 9400 1800 NW 316 1476 504 NW 3700 1800 7100 CW 4711 030 8019 14400 CW 5900 700 10000 1900 CW 4000 1950 7600 CW 4000 1950 7600 Efficacy (lm/w) WW 47 5 49 53 W7 47 53 46 51 NW 53 57 53 56 CW 61 61 63 59 Color Temp WW 3000K 3000K 3000K 3000K W7 700K 700K 700K 700K NW 4000K 4000K 4000K 4000K CW 5000K 5000K 5000K 5000K CRI WW/W7/NW/CW 85/85/85/67 85/85/85/67 85/85/85/67 85/85/85/67 Beam Angle 10, 15, 5, 40 10, 15, 5, 40 15, 5, 40 15, 5, 40 Warranty 5 years 5 years 5 years 5 years MOL 5.08, 19mm 5.08, 19mm 4.57, 116mm 4.57, 116mm Rating cul, FCC, RoHS cul, FCC, RoHS cul, FCC, RoHS cul, FCC, RoHS Dimmable 1 Yes Yes Yes Yes NFL: Narrow Flood FL: Flood SP: Spot NSP: Narrow Spot NW: Neutral White WW: Warm White W7: Warm White 700K CW: Cool White 1 I www.lsgc.com
PAR0 PAR0 Hi-Output BR40 BR30 Comparable 50W halogen 90W halogen 90W Incandescent 75W Incandescent Equivalence 8 8 18 15 Voltage 10VAC 10 VAC 10 VAC 10 VAC Beam Angle 5 40 5 40 Output (lumens) WW 350 350 WW 45 45 WW 900 WW 800 W7 35 310 W7 415 415 W7 875 W7 75 NW 350 370 NW 450 450 NW 950 NW 844 CW 508 508 CW 480 480 CW 1006 CW 895 Center Beam 5 40 5 40 Candle Power WW 1057 650 WW 1400 860 (candelas) W7 1175 570 W7 1350 840 NW 138 714 NW 1450 900 CW 1797 1036 CW 1550 950 Efficacy (lm/w) WW 44 53 50 50 W7 41 5 49 48 NW 44 56 53 56 CW 64 60 56 60 Color Temp 3000K 3000K 3000K 3000K 700K 700K 700K 700K 4000K 4000K 4000K 4000K 5000K 5000K 5000K 5000K CRI WW/W7/NW/CW 85/85/85/67 85/85/85/67 80/80/80/67 80/80/80/67 Beam Angle 5, 40 5, 40 Warranty 5 years 5 years 5 years 5 years MOL 3.46, 86mm 3.4, 86mm 6.565, 166.7mm 5.375, 136.5mm Rating cul, FCC, RoHS cul, FCC, RoHS cul, FCC, RoHS cul, FCC, RoHS Dimmable 1 Yes Yes Yes Yes NFL: Narrow Flood FL: Flood SP: Spot NSP: Narrow Spot NW: Neutral White WW: Warm White W7: Warm White 700K CW: Cool White Specifications supplied are nominal. Please refer to the DOE s Lighting Facts Tolerance Guidelines. 1 See dimmer compatibility chart page 5. 30V Available www.lsgc.com I
DEFINITY Lamp Range MR16 GU10 PAR16 MR16 Comparable 30W Halogen 30W Halogen 0W Halogen Equivalence 6W 60W 6W Voltage 10 VAC 3 10 VAC 3 See page 6 Beam Angle 5 40 5 40 5 40 Output (lumens) WW 35 35 95 300 95 300 W7 315 315 50 50 50 50 NW 345 345 75 318 75 318 CW 365 365 44 44 44 44 Center Beam 5 40 5 40 5 40 Candle Power WW 1100 450 768 584 768 584 (candelas) W7 1050 435 930 487 930 487 NW 1150 470 98 568 98 568 CW 100 510 1516 860 1516 860 Efficacy (lm/w) WW 54 49 49 W7 53 4 4 NW 58 Up to 58 Up to 58 CW 61 71 71 Color Temp WW 3000K 3000K 3000K W7 700K 700K 700K NW 4000K 4000K 4000K CW 5000K 5000K 5000K CRI WW/W7/NW/CW 85/85/85/67 85/85/85/67 85/85/85/67 Beam Angle 5, 40 5, 40 5, 40 Warranty 3 years 3 years 3 years MOL 1.97, 50mm 1.94, 49.33mm 1.94, 49.33mm Rating FCC FCC FCC Dimmable No Yes Yes NFL: Narrow Flood FL: Flood SP: Spot NSP: Narrow Spot NW: Neutral White WW: Warm White W7: Warm White 700K CW: Cool White 3 I www.lsgc.com
A19 DFN19 DFN5 Comparable 60W Incandescent 40W Incandescent 50W Incandescent Equivalence 13.5W 8W 8W Voltage 10 VAC 10 VAC 3 10 VAC 3 Equivalence 40W 60W Output (lumens) WW 45 850 WW 435 WW 450 W7 400 800 W7 395 W7 380 NW 450 890 NW 460 NW 475 CW 475 945 CW 570 CW 575 Efficacy (lm/w) WW 5 61 54 56 W7 50 59 53 48 NW 56 69 58 59 CW 59 73 71 71 Color Temp WW 3000K 3000K 3000K 3000K W7 700K 700K 700K 700K NW 4000K 4000K 4000K 4000K CW 5000K 5000K 5000K 5000K CRI WW/W7/NW/CW 85/85/85/67 85/85/85/67 85/85/85/67 85/85/85/67 Warranty 5 years 5 years 5 years 5 years MOL 4.3 4.3 4.39, 111.6mm 4.68, 118.88mm Rating cul, FCC cul, FCC cul, FCC, RoHS cul, FCC, RoHS Dimmable Yes Yes Yes Yes NFL: Narrow Flood FL: Flood SP: Spot NSP: Narrow Spot NW: Neutral White WW: Warm White W7: Warm White 700K CW: Cool White Specifications supplied are nominal. Please refer to the DOE s Lighting Facts Tolerance Guidelines. 1 For directional lamps, Energy Star early submission dictates that manufacturers can only claim 5,000 hour life with 3,000 hour actual life test data, 6,000 hour LM80 data and in-situ temperature measurements. Once a product has been fully qualified, manufacturers may increase the lifetime of a product by demonstrating full compliance with the ENERGY STAR criteria at the new lifetime with Lumen Maintenance at the minimum required test period. Meets L70 lumen depreciation criteria. See dimmer compatibility chart page 5. 3 30V Available www.lsgc.com I 4
Wall Box Dimmers PAR38\PAR38 Hi-Output Manufacturer Product Model # Min. Max. Lutron Diva DVLV-600P 1 5 Lutron Skylark SELV-300P 1 4 Lutron Nova NVL-600 1 5 Other dimmers include: Ace 34050, 307596, Cooper 9536AD, Leviton 6633-PL, 6684, 6631, IPI06-1LX, Lutron S-600PR-WH, DV-600PR-WH, TG-600PR-WH, AY600P, Q600P, GL600, CN-600PHW, DV-603PG, S-600, S-600P, LG-600P, D-600PH, TT-300NLH, TG-603PG, HW/ LP-RPM-4A-10, HW/LP-RPM-4U-10, QSG-6D, GP(Harrier) Card w/grx-3503, HW/LP- RPM-4A-10, HW/LP-RPM-4U-10, QSG-6D, GP (Harrier) Card w/ GRX-3503, PHPM-WBX w/ DVF-103P, PHPM-PA w/qsg-6d, Legrand DrRD4W PAR30\PAR30 Hi-Output Manufacturer Product Model # Min. Max. Lutron Diva DVLV-600P 1 9 Lutron Nova NLV-600 1 9 Other dimmers include: Ace 34050, 307596, Cooper 9536AD, Leviton 6633-PL, 6684, 6631, IPI06-1LX, Lutron S-600PR-WH, DV-600PR-WH, TG-600PR-WH, AY600P, Q600P, GL600, CN- 600PHW, DV-603PG, S-600, S-600P, LG-600P, D-600PH, TT-300NLH, TG-603PG, HW/LP-RPM- 4A-10, HW/LP-RPM-4U-10, QSG-6D, SZ-6ND, HW/LP-RPM-4A-10, HW/LP-RPM-4U-10, HxD-6ND, QSG-6D, PHPM-WBX w/dvf-103p, PHPM-PA w/qsg-6d, Legrand DrRD4W PAR0\PAR0 Hi-Output Manufacturer Product Model # Min. Max. Lutron Vierti VTELV-600M 1 1 Lutron Diva DVLV-600P 1 7 Lutron Diva DV-600 1 7 Lutron Ariadni AY-600 1 7 Lutron Skylark S-600 1 7 Lutron Diva DV(W)CL-153P 1 18 Lutron Maestro MA-600 1 7 Lutron Maestro MAELV-600 1 1 Lutron Nova T NTLV-600 1 7 Lutron Nova T NTELV-600 1 1 Lutron Skylark SELV-300P 1 6 Lutron Diva DVELV-300P 1 6 Lutron Nova T NELV-450 1 9 Other dimmers include: Ace 34050, 307596, Leviton 6633-PL, 6684, 6631, IPI06-1LX, Lutron S-600PR-WH, DV-600PR-WH, TG-600PR-WH, AY600P, Q600P, GL600, CN-600PHW, DV-603PG, S-600P, LG-600P, D-600P, D-600PH, TT-300NLH, TG-603PGDVCL-153P, RRD-10ND, SZ-6ND, HW-RPM-4A-10, HxD-6ND, QSG-6P, LP-RPM-4A-10, PHPM-WBX, Legrand DrRD4W A19 Omni-directional Manufacturer Product Model # Min. Max. Lutron Vierti VTELV-600M 1 9 Lutron Diva DVLV-600P 1 5 Lutron Diva DV-600 1 5 Lutron Ariadni AY-600 1 5 Lutron Skylark S-600 1 5 Lutron Diva DV(W)CL-153P 1 14 Lutron Maestro MA-600 1 5 A19 Omni-directional cont. Manufacturer Product Model # Min. Max. Lutron Maestro MAELV-600 1 9 Lutron Nova T NTLV-600 1 5 Lutron Nova T NTELV-600 1 9 Lutron Skylark SELV-300P 1 4 Lutron Diva DVELV-300P 1 4 Lutron Nova T NELV-450 1 7 Other dimmers include: Ace 34050, 307596, Leviton 6633-PL, 6684, 6631, IPI06-1LX, Lutron S-600PR-WH, DV-600PR-WH, TG-600PR-WH, AY600P, Q600P, GL600, CN- 600PHW, DV-603PG, S-600P, LG-600P, D-600PH, TT-300NLH, TG-603PG, DVCL-153P, RRD-10ND, SZ-6ND, HW-RPM-4A-10, HxD-6ND, QSG-6P, LP-RPM-4A-10, PHPM-WBX, Legrand DrRD4W DFN19 Manufacturer Product Model # Min. Max. Lutron Vierti VTELV-600M 1 1 Lutron Diva DVLV-600P 1 8 Lutron Diva DV-600 1 8 Lutron Ariadni AY-600 1 8 Lutron Skylark S-600 1 8 Lutron Diva DV-(W)CL-153P 1 18 Lutron Maestro MAELV-600 1 1 Lutron Nova Tn NTLV-600 1 8 Lutron Nova Tn NTELV-600 1 1 Lutron Skylark SELV-300P 1 6 Lutron Diva DVELV-300P 1 6 Lutron Nova NLV-600 1 8 Lutron Nova NELV-450 1 9 Other dimmers include: Ace 34050, 307596, Leviton 6633-PL, 6684, 6631, IPI06-1LX, Lutron S-600PR-WH, DV-600PR-WH, TG-600PR-WH, AY600P, Q600P, GL600, CN- 600PHW, DV-603PG, S-600P, LG-600P, D-600PH, TT-300NLH, TG-603PG, DVCL-153P, RRD-10ND, SZ-6ND, HW-RPM-4A-10, HxD-6ND, QSG-6P, LP-RPM-4A-10, PHPM-WBX, Legrand DrRD4W DFN5 Manufacturer Product Model # Min. Max. Lutron Vierti VTELV-600M 1 15 Lutron Diva DV(W)CL-153P 1 18 Lutron Maestro MAELV-600 1 15 Lutron Nova T NTLV-600 1 8 Lutron Nova T NTELV-600 1 15 Lutron Skylark SELV-300P 1 7 Lutron Diva DVELV-300P 1 7 Lutron Nova NELV-450 1 11 Lutron Nova N-600 1 8 Other dimmers include: Ace 34050, 307596, Leviton 6633-PL, 6684, 6631, IPI06-1LX, Lutron S-600PR-WH, DV-600PR-WH, TG-600PR-WH, AY600P, Q600P, GL600, CN-600PHW, DV-603PG, S-600, S-600P, LG-600P, D-600PH, TT-300NLH, TG-603PG, DVCL-153P, RRD-10ND, SZ-6ND, HW-RPM-4A-10, HxD-6ND, QSG-6P, LP-RPM-4A-10, PHPM-WBX, Legrand DrRD4W 5 I www.lsgc.com
MR16 Transformer Compatability Brand Model Input Voltage (VAC/Hz) Power Rating (W) Type Number of MR16s per Transformer 1 3 4 5 6 Advance 71A9743 10 VAC, 60 Hz 75 MT G G G G G G CHD HUA100600XL 10 VAC, 60 Hz 60 ET G G G G G G ELG 50LED100W 10 VAC, 60 Hz 100 ET G G G G G G 50LED10W 10 VAC, 60 Hz 10 ET G N/A N/A N/A N/A N/A 50AT075T 10 VAC, 60 Hz 75 MT G G G G G G Hatch RS1-15M-LED 10 VAC, 50-60 Hz 15 ET G G N/A N/A N/A N/A PS1-0L 10 VAC, 60 Hz 0 ET F F G N/A N/A N/A RS1-30M-LED 10 VAC, 50-60 Hz 30 ET G G G G N/A N/A RS1-60M 10 VAC, 50-60 Hz 60 ET G G G G G G VS1-60W 10 VAC, 50-60 Hz 60 ET G G G G G G VS1-60WD 10 VAC, 50-60 Hz 60 ET G G G G F G RS1-80M 10 VAC, 50-60 Hz 80 ET G G G G G G RS1-60M-LED 10 VAC, 50-60 Hz 15 ET G G G G G G LCI i60e 30 VAC, 50-60 Hz 60 ET G G G G G G Lightech LET-60 10 VAC, 50-60 Hz 60 ET F F F F F F LET-75 10 VAC, 50-60 Hz 75 ET F F F F F F Ligro E1SC50SA 30 VAC 50 MT G G G G G G Lumex MTR50/1 EN-61558 0VAC, 50 Hz 50 MT G G G G G G MDL 319-0103 10 VAC, 50-60 Hz 10 ET G N/A N/A N/A N/A N/A Mirano BLNET-L50C 50W 0 VAC, 50-60Hz 50 ET G G G G G G Niko 30-0011 30 VAC, 50 Hz 105 ET G G G G G G Nobile EN-60D 30 VAC, 50-60 Hz 60 ET G F F F F F EN-60D 30 VAC, 50-60 Hz 60 ET G F G F F G EN-70D 30 VAC, 50-60 Hz 70 ET F F F G G G EN-80D 30 VAC, 50-60 Hz 80 ET G G G G G G EN-80D 30 VAC, 50-60 Hz 80 ET G G G G F F EN-110D 30 VAC, 50-60 Hz 110 ET G G G G G G EN-110D 30 VAC, 50-60 Hz 110 ET F F F F F F Osram HTM 150/30-40 30-40 VAC, 50-60 Hz 150 ET G G G G G G Philips Primaline 105 30-40 30-40 VAC, 50-60 Hz 105 ET G G G G G G Xitanium 10W Dimmable 0-40 VAC, 50-60 Hz 10 ET G N/A N/A N/A N/A N/A Sunrise H0050-497 10 VAC, 50-60 Hz 50 MT G G G G G G Teca 100D851S 10 VAC, 60 Hz 100 MT G G G G G G Tridonic VIPER 176074 30-40 VAC, 50-60 Hz 105 ET G F G F G F VIPER 17607 30-40 VAC, 50-60 Hz 105 ET G G F F F F VadsBO SET70RE-1 0-40 VAC, 50 Hz 70 ET G G G G G G Vossioh Schwabe EST 70/1.380 30-40 VAC, 50-60 Hz 70 ET G G G G G G EST 105/1.381 30-40 VAC, 50-60 Hz 105 ET G G G G G G EST 150/1.6 30-40 VAC, 50-60 Hz 150 ET G G G G G G WAC EN-1100-R-AR 10 VAC, 50-60 Hz 100 ET G G G G G G Wang WH-601ECA-L 10 VAC, 60 Hz 60 ET G G G G G G Et - Electronic Transformer MT - Magnetic Transformer G - Good F - Flickers N/A - Exceeds Transformer Recommended Power www.lsgc.com I 6
Changing the way the world experiences light. Corporate Office 17 S. Patrick Drive BLDG A Satellite Beach, Florida 3937 t: +1.31.779.550 t: 877.999.574 f: +1.31.779.551 www.lsgc.com North America Asia Australia Europe 011 Lighting Science Group Corporation. All rights reserved. Specifications are subject to change. LSG_054_DFN_Brochure_rev