Axial Piston Variable Pump A7VO

Similar documents
Axial Piston Fixed Pump A2FO

2-Circuit Axial Piston Fixed Pump A18FDO

Axial Piston Fixed Pump A17FNO

Axial Piston Variable Pump A18VLO

Axial Piston Variable Pump KVAA

Axial Piston Variable Pump A18VLO Series 11

Axial Piston Variable Double Pump A8VO

Axial Piston Fixed Motor A2FNM for Fan Drives and Flywheel Mass

Axial Piston Fixed Pump A17FNO Series 10

Axial piston fixed pump A17FO Series 10

Axial piston fixed pump A17FNO Series 10

Axial Piston Variable Pump A10VSNO

Axial Piston Variable Pump A4VTG

Axial Piston Variable Pump A4VTG

Axial piston fixed pump AA2FO

Fixed Displacement Pump A2FO

Axial Piston Variable Pump A10VSO

Axial Piston Variable Pump A18VO Series 11

Axial Piston Variable Pump A17VO

Axial Piston Fixed Displacement Pump KFA

Variable Plug-In Motor A6VE

Axial Piston Variable Pump AA11VO

Fixed Plug-In Motor A2FE

Axial piston variable pump A4VG Series 40

Axial Piston Fixed Motor A2FM

Axial piston variable pump A4VG Series 40

Axial Piston Variable Pump A10VSNO

Axial piston variable pump A10VSO Series 31

Axial piston variable pump A1VO series 10

Axial Piston Variable Pump A11VO

Axial piston variable pump A10V(S)O Series 31

Axial piston variable pump A4VG Series 40

Axial Piston Variable Motor A6VM

Axial Piston Variable Pump A10VO

Axial Piston Variable Pump A1VO Series 10

Axial piston variable pump A10VSO series 32. Americas. RE-A Issue: Replaces:

Axial Piston Variable Pump A10VSO

Variable Displacement Plug-In Motor A6VE

Axial piston variable pump A10V(S)O Series 31. Americas. RE-A Edition: Replaces:

Axial Piston Variable Pump A4VG

Axial piston variable pump A7VO

Axial piston fixed motor A2FM Series 70 A2FE Series 70

Axial piston variable pump A18VO series 11

Axial piston variable pump (A)A10VSO Series 31. Americas. RE-A Edition: Replaces:

Fixed Displacement Motor A10FM A10FE

Axial piston variable pump A10VSO series 32

Axial piston variable pump A4VG Series 40. Americas. RE-A Edition: Replaces:

Axial piston variable pump A10VO series 52 and 53

Axial piston variable pump A4VG Series 32. Europe. RE-E Edition: Replaces:

Axial Piston Variable Pump AA10VG

Axial Piston Variable Motor A6VM

Axial Piston Variable Displacement Pump AA11VO

Variable Plug-in Motor A6VE

Axial Piston Variable Pump A10VO (US-Version)

Axial Piston Variable Pump A2VK

Axial piston fixed motor A2FM series 70. Americas. RE-A Edition:

Axial piston variable pump A10VO Series 32

Axial piston variable pump A15VSO, A15VLO series 10 (US-Version)

Axial Piston Variable Pump AA4VG

Axial piston variable pump A11V(L)O series 40

Axial piston variable pump A10VO series 52 and 53. Americas. RE-A Edition: Replaces:

Axial piston variable pump A10VO series 52 and 53

Axial Piston Variable Pump A15VSO

Axial Piston Variable Pump A10VO

Axial piston variable double pump A28VLO Series 10

Fixed Displacement Motor A2FM

Axial Piston Variable Pump A4VG

Axial piston variable pump A11V(L)O Series 40

Axial piston variable pump A1VO Series 10

Axial piston variable motor A6VM series 71

Axial Piston Variable Motor AA6VM (A6VM)

Fixed Plug-In Motor A2FE

Axial piston variable pump A10VO series 52 and 53

Fixed Displacement Plug-In Motor A2FE

Variable Axial Piston Pump A10V Series - 52/53

Variable Displacement Plug-In Motor A6VE

Axial piston fixed motor A2FM for explosive areas II 2G ck IIB Tx

Variable Displacement Pump A4VG for closed circuits

Axial piston variable pump. A10VNO series 53. RE Edition: Replaces:

Brueninghaus Hydromatik Rexroth A2FO Pump & A2FM Motor

Radial piston pump, fixed displacement

Fixed Displacement Motor AA2FM (A2FM)

Radial piston pump PR4 Series 1X

Axial piston variable motor A6VM Series 63. Europe. RE-E Edition: Replaces:

Axial piston variable pump (A)A4VSO

Fixed Displacement Pump A4FO Series 10 Axial Piston Unit, Swashplate Design

Axial Piston Variable Pump A15VSO

Radial piston pump PR4 series 1X

Axial piston variable pump A10VSO Series 31 for explosive areas ATEX II 3G ck IIB T4

Axial Piston Variable Motor A6VM

Fixed displacement radial piston pump

Axial piston variable pump A4CSG Series 3x

Variable Displacement Motor AA6VM (A6VM)

ENGINEERING DATA. Variable Axial Piston Pump A10V Series - 52/53. w w w. F l u i D y n e F P. c o m E m a i l : F l u i D y n e F P.

Axial piston variable pump with electro-proportional control A10VO... EP../EK..

Counterbalance Valve BVD

Axial Piston Variable Motor A6VM (US-Version)

Brueninghaus Hydromatik Rexroth A6VM Motor

Axial piston variable motor A6VM series 65. Americas. RE-A Edition: Replaces:

Axial piston variable pump. A10VNO series 53. Americas. RE-A Edition: Replaces:

Transcription:

Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics ervice Axial Piston Variable Pump A7VO E 92 202/03.06 1/32 eplaces: 07.95 Technical data sheet eries 6 izes 28...160 Nominal pressure 350 bar Peak pressure 400 bar open circuit Contents Ordering Code / tandard Program 2 Technical Data 3...6 Power Control 7...9 D Pressure Control 10...12 HD Hydraulic Control, Pilot Pressure elated 13...14 EP Electrical Control with Proportional olenoid 15 nit Dimensions, ize 28 16...18 nit Dimensions, ize 55 19...21 nit Dimensions, ize 80 22...24 nit Dimensions, ize 107 25...27 nit Dimensions, ize 160 28...30 Installation Notes 31 General Notes 32 Features Variable pump with axial tapered piston rotary group of bent axis design for hydrostatic drives in open circuit se in mobile and industrial applications The output flow is proportional to the drive speed and pump displacement and is steplessly variable between maximum and zero (q v max to q v min = 0) Wide selection of regulating and control devices ugged, compact bearing system with long service life

2/32 Bosch exroth AG A7VO E 92 202/03.06 Ordering Code / tandard Program A7V O / 63 B 01 01 02 03 04 05 06 07 08 09 10 Axial piston unit 01 Bent axis design, variable, nominal pressure 350 bar, peak pressure 400 bar A7V Operation mode 02 Pump, open circuits O ize 03 Displacement V g max in cm 3 28 55 80 107 160 see E 92203 250 355 500 Control device 28 55 80 107 160 Power control with pressure cut-off with pressure cut-off and stroke limiter negative characteristic Δp = 25 bar DH1 D 04 with stroke limiter negative characteristic Δp = 25 bar H1 Pressure control D remote controlled DG with load sensing D Hydraulic control, pilot pressure related Δp = 10 bar HD1 for pressure cut-off, remote controlled Δp = 10 bar HD1G pilot pressure related Δp = 25 bar HD2 for pressure cut-off, remote controlled Δp = 25 bar HD2G Electrical control, with proportional solenoid for pressure cut-off, remote controlled EP EPG eries 28 55 80 107 160 05 eries 6, Index 3 63 Direction of rotation 28...160 Viewed on shaft end clockwise 06 counter-clockwise L eals 28 55 80 107 160 07 NB (nitril-caoutchouc), shaft seal in FKM (fluor-caoutchouc) N 08 haft end 28 55 80 107 160 plined shaft, DIN 5480 Z Parallel keyed shaft, DIN 6885 Mounting flange 28 55 80 107 160 09 4-hole IO 3019-2 B ervice line ports 28 55 80 107 160 10 AE pressure port, rear (metric fastening thread) 01 AE suction port, rear (metric fastening thread) P = preferred program

E 92 202/03.06 A7VO Bosch exroth AG 3/32 Technical Data Hydraulic fluid Before starting project planning, please refer to our data sheets E 90220 (mineral fluid), E 90221 (environmentally acceptable press ure fluids) and E 90223 (HF pressure fluids) for detailed information regarding the choice of pressure fluids and conditions of use. The A7VO variable pump is not suitable for use with HFA. If HFB, HFC and HFD or environmentally acceptable pressure fluids are being used, the limitations regarding technical data and seals mentioned in E 90221 and E 90223 must be observed. When ordering please indicate the used hydraulic fluid. Viscosity range We recommend that a viscosity (at operating temperature) for optimum efficiency and service life purposes of ν opt = optimum viscosity 16...36 mm 2 /s be chosen, taken the tank temperature (open circuits) into account. Limits of viscosity range The following values apply in extreme cases: ν min = 5 mm 2 /s short term (t < 3 min) at max. permitted temperature t max = +115 C. ν max = 1600mm 2 /s, short term (t < 3 min) with cold start (p < 30 bar, n 1000 rpm, t min = -40 C). Note that the maximum hydraulic fluid temperature of 115 C must not be exceeded locally either (e.g. bearing area). The temperature in the bearing area is - depending on pressure and speed-up to 12 K higher than the average leakage fluid temperature. pecial measures are necessary at temperatures between -40 C and -25 C. Please contact us. ee E 90300-03-B for detailed information about use at low temperatures. election diagram -40-20 1600 1000 600 400 vis co si ty ν in mm 2 /s 200 100 60 40 20 10 0 20 40 60 80 100 1600 5 5-40 -25-10 0 10 30 50 70 90 115 tem pe ra ture t in C t min = -40 C VG 22 VG 32 VG 46 VG 68 VG 100 hydraulic fluid temperature range 36 16 t max = +115 C Details regarding the choice of hydraulic fluid The correct selection of hydraulic fluid requires knowledge of the operating temperature in relation to the ambient temperature, in an open circuit the tank temperature. The hydraulic fluid should be selected so that within the operating temperature range, the operating viscosity lies within the optimum range (ν opt ) (see shaded section of the selection diagram). We recommend that the highest possible viscosity range should be chosen in each case. Example: At an ambient temperature of X C an operating temperature of 60 C is set in the circuit. In the optimum viscosity range (ν opt ; shaded area) this corresponds to the viscosity classes VG 46 or VG 68; to be selected: VG 68. Please note: The leakage fluid temperature, which is affected by pressure and rotational speed, is always higher than the tank temperature. At no point in the system may the temperature be higher than 115 C. If this cannot be achieved due to unusual operating parameters or high ambient temperatures, we recommend to apply bearing flushing at port. Filtration The finer the filtration, the cleaner the fluid and the longer theservice life of the axial piston unit. To ensure proper function of the axial piston unit, the hydraulic fluid must have a cleanliness level of at least 20/18/15 according to IO 4406. At very high hydraulic fluid temperatures (90 C to max. 115 C), a cleanliness level of at least 19/17/14 according to IO 4406 is required. Please contact us if these cleanliness leveles cannot be achieved.

4/32 Bosch exroth AG A7VO E 92 202/03.06 Technical Data Operating pressure range Inlet Pressure at port The minimum inlet pressure depends on the speed. The following limits may not be exceeded. p abs min 0,8 bar The maximum pressure p abs max also depends on speed (see succeeding diagram). Minimum inlet pressure at suction port with increased speed In order to avoid damage of the pump a minimum inlet pressure at the suction port must be assured. The minimum inlet pressure is related to the rotational speed and the displacement of the variable pump. 1,5 2,3 n n max 1 peed 1,4 2,0 1,9 1,3 1,8 1,7 1,6 1,2 1,5 1,4 1,3 1,1 1,2 1,1 1,0 1,0 0,9 0,9 0,8 0,8 0,6 0,7 0,8 0,9 1,0 Displacement V g V g max Note: max. permissible speed n max perm. (speed limit, see page 5) min. and max. permissible inlet pressure at port permissible values for the shaft seal ring Outlet Maximum pressure at port A or B (pressure specifications in according to DIN 24312) no radial loading (coupling) with radial loading 1 ) (pinion or belt drive) Nom. pressure p N Inlet pressure pabs in bar Peak pressure p max 350 bar 400 bar 315 bar 400 bar 1 ) please observe the permissible radial loading, see page 6 Leakage fluid The leakage fluid chamber is connected to the suction chamber. A leakage fluid line to the tank is not required (both ports are plugged). Exception: A leakage fluid line for discharge from port T 1 to the tank is imperatively necessary for pressure control or pressure cut-off. haft seal ring Permissible pressure load The service life of the shaft seal ring is affected by the speed of the pump and the leakage fluid pressure (max. permissible leackage fluid pressure 6 bar abs. at reduced speed, as to diagram). hort-term (t < 5 s) pressure spikes of up to 10 bar absolute are permitted. The more frequently the pressure peaks are occurring, the shorter the service life of the shaft seal ring. It is recommended the average permanent leakage fluid pressure must not exceed 3 bar absolute. The pressure in the case must be equal to or greater than the external pressure on the shaft seal ring. The pure mechanical resistance to case pressure is approximately 20 bar. Perm. pressure pabs. max. (bar) 6 5 4 3 2 1 size 107 size 160 size 28 size 55 size 80 0 2000 4000 6000 peed n (rpm) Temperature range The FKM shaft seal ring is admissible for a case temperature range from -25 C to +115 C. Note: For applications below -25 C a NB shaft seal ring is necessary as special version (admissible temperature range -40 C to +90 C). When ordering indicate NB shaft seal ring in clear text. Direction of flow Direction of rotation, viewed on shaft end clockwise counter-clockwise to B to A

E 92 202/03.06 A7VO Bosch exroth AG 5/32 Technical Data Table of values (theoretical values, ignoring η mh and η v ; values rounded) ize 28 55 80 107 160 Displacement V g max cm 3 28,1 54,8 80 107 160 peed max. 1 ) at V g max n max1 rpm 3150 2500 2240 2150 1900 at V g < 0,74 V g max (see diagram, page 4) n max2 rpm 4250 3400 3000 2900 2560 peed max. 2 ) n max perm. rpm 4750 3750 3350 3200 2850 Flow at n max1 and V g max q v max1 L/min 89 137 179 230 304 Power at q v max1 and Δp = 350 bar P max1 kw 52 80 105 134 177 Torque at V g max and Δp = 350 bar T max Nm 156 305 446 596 891 Mass moment of inertia (of the rotating parts) J kgm 2 0,0042 0,0042 0,0080 0,0127 0,0253 Filling capacity V L 0,5 0,75 1,2 1,5 2,4 Mass (approx.) m kg 17 25 40 49 71 1 ) The values shown are valid for an absolute pressure (p abs ) of 1 bar at the suction port and when operated on mineral fluid with a specific mass of 0,88 kg/l. 2 ) Maximum speed (speed limit) for an increase in the inlet pressure p abs at the suction port and V g < V g max Determining the size Flow q v = Torque T = Power P = V g n η v 1000 V g Δp 20 π η mh 2 π T n = q v Δp 60000 600 η t L/min Nm kw V g = Displacement per revolution in cm 3 Δp = Differential pressure in bar n = peed in rpm η v = Volumetric efficiency η mh = Mechanical-hydraulic efficiency η t = Overall efficiency

6/32 Bosch exroth AG A7VO E 92 202/03.06 Technical Data Permissible radial and axial loading on the drive shaft The values given are maximum values and do not apply to continuous operation. ize 28 55 80 107 160 adial force, max. F q Fq max N 5696 9280 11657 13580 18062 at distance a from shaft collar a a mm 12,5 15 17,5 20 22,5 adial force/bar operating pressure 1 ) F q /bar N/bar 14,2 23,2 29,1 34 45,2 Axial force, max. 2 ) - +F ax max N 315 500 710 900 1120 F ax + F ax max N 315 500 710 900 1120 Perm. axial force/bar operating pressure ±F ax zul. /bar N/bar 4,6 7,5 9,6 11,3 15,1 1 ) at gear drive (DIN 867) with smallest PCD of pinion D min and V g max (D min = 2,5 x diameter of drive shaft). Preload required/bar operating pressure (radial force) to transmit torque at V-belt drive (DIN 7753) with smallest pulley diameter D K min und V g max (D K min = 5 x diameter of drive shaft). 2 ) max. permissible axial force when stopped or when axial piston unit working in pressureless conditions When considering the permissible axial force, the force-transfer direction must be taken into account: F ax max = increase in service life of bearings + F ax max = reduction in service life of bearings (avoid if at all possible) Effect of radial force F q on the service life of the bearings By selecting a suitable force-transfer direction of F q, the stress on the bearing caused by the internal transmission forces can be reduced, thus achieving the optimum service life for the bearing. ecommended position of mating gear depending on direction of rotation. Examples: Gear drive V-belt drive ϕ opt = 45 ϕ opt = 45 ϕ opt = 70 ϕ opt = 70 Clockwise direction of rotation Pressure on port B Counter-clockwise direction of rotation Pressure on port A Clockwise direction of rotation Pressure on port B

E 92 202/03.06 A7VO Bosch exroth AG 7/32 Power Control The power control regulates the displacement of the pump depending on the operating pressure so that a given drive power is not exceeded at constant drive speed. p B V g = constant p B = operating pressure; V g = displacement The precise control with a hyperbolic control characteristic, provides an optimum utilization of available power. The operating pressure acts on a rocker via a piston. An externally adjustable spring force counteracts this, it determines the power setting. If the operating pressure exceeds the set spring force, the control valve is actuated by the rocker, the pump swivels back (direction V g min ). The lever length at the rocker is shortened and the operating pressure can increase at the same rate as the displacement decreases without the drive powers being exceeded (p B V g = constant). In zero pressure non-running condition, the pump is swivelled to its starting position (V g max ) by means of the control spring. etting range for start of control 50 220 bar The output power (characteristic) is influenced by the efficiency of the pump. tate in clear text in the order: drive power P in kw drive speed n in rpm max. flow q V max in l/min After clarifying the details a power diagram can be created by our computer. Characteristic Operating pressure pb in bar V g min Displacement V g max Circuit diagram V g min 220 bar etting range tart of control 50 bar V g max B (A) A1 X3 T1

8/32 Bosch exroth AG A7VO E 92 202/03.06 Power Control D Power control with pressure cut-off Characteristic D Pressure cut-of is a pressure control that adjusts the pump displacement back towards V g min when a preset pressure value is reached. This function overrides the power control, i.e. below the preset pressure value, the power function is effective. The pressure cut-off is preset to a specified value at the factory. etting range for pressure cut-off 200 350 bar When ordering, state in clear text the setting of the pressure cut-off. Note: Operating pressure pb in bar etting range 350 max 200 min At the start of control of the power control the max. permissible setting of the pressure cut-off has to be multiplied by factor 5. Example: tart of control (power control): 50 bar max. perm. setting of pressure cut-off: 50 bar 5 = 250 bar The version with pressure cut-off necesitates a leakage fluid line from port T 1 to the tank. With plugged leackage fluid port a permissible duration of operation of the pressure cut-off 2 min is resulting at t tank 50 C. Any pressure relief valve included in the circuit to limit the max. pressure must be set to a cracking pressure at least 20 bar above the pressure control setting. V g min Circuit diagram D Displacement V g min V g max V g max A1 B (A) X3 T1

E 92 202/03.06 A7VO Bosch exroth AG 9/32 Power Control... Power control with stroke limiter Circuit diagram H1 The hydraulic stroke limiter can be used to vary or limit the displacement of the pump continuously over the whole control range. The displacement is set with the pilot pressure p t (max. 40 bar) applied to port X 1. The power control overrides the hydraulic stroke limiter control, i.e. below the hyperbolic power characteristic, the displacement is controlled, by the pilot pressure. When exceeding the power characteristic with a set flow or load pressure, the power control overrides and reduces the displacement following the hyperbolic characteristic. X1 V g min V g max Y3 B (A) A1 X3 A control pressure of 40 bar is required to swivel the pump from its starting position V g min to V g max. The required control pressure is taken either from the operating pressure, or from the externally applied control pressure at the port. T1 To ensure the control even at low operating pressure < 40 bar the port must be supplied with an external control pressure of approx. 40 bar. Circuit diagram DH1 H1 Hydraulic stroke limiter (negative characteristic) X1 Y3 Control from V g max to V g min With increasing pilot pressure the pump swivels to a smaller displacement. etting range for start of control 4 15 bar When ordering, state in clear text the start of control. V g max B (A) A1 tarting position without control signal (pilot pressure): V g max Characteristic H1 Increase in pilot pressure (V g max V g min ) Δp = 25 bar 40 35 V g min X3 T1 Pilot pressure pt in bar 30 25 20 15 10 4 0 0,2 0,4 0,6 0,8 1,0 V g min Displacement V g max etting range

10/32 Bosch exroth AG A7VO E 92 202/03.06 D Pressure Control The pressure control keeps the pressure in a hydraulic system constant within its control range even under varying flow conditions. The variable pump only moves as much hydraulic fluid as is required by the actuators. If the operating pressure exceeds the setpoint set at the integral pressure control valve, the pump displacement is automatically swivelled back until the pressure deviation is corrected. In zero pressure non-running condition, the pump is swivelled to its starting position V g max by means of the control spring. etting range for pressure control 50 350 bar When ordering, state in clear text the setting of the pressure control. Note: The version with pressure control D necesitates a leakage fluid line from port T 1 to the tank. Any pressure relief valve included in the circuit to limit the max. pressure must be set to a cracking pressure at least 20 bar above the pressure control setting. Zero stroke operation The standard pump unit is designed for intermittent constant pressure operation. hort-term operation at zero stroke (< 10 min.) is permissible up to a operating pressure p max = 315 bar at a tank temperature of 50 C. For long-term periods of zero stroke operation, port should be used for bearing flushing. Flushing port Characteristic D Operating pressure pb in bar etting range 350 max 50 min max. 10 bar Flushing flow (recommended) ize 28 55 80 107 160 q v flush (L/min) 3 4 6 8 12 Temperatur of flushing fluid tank temperatur Flow q v in L/min Circuit diagram D B (A) V g min V g max A1 X3 T1

E 92 202/03.06 A7VO Bosch exroth AG 11/32 D Pressure Control DG Pressure control, remote controlled A sequence valve with port plate takes over the function of the pressure cut-off. The valve is mounted separate from the pump, and the simple piping length should not exceed 5 m. High pressure is supplied from the pump to the valve via port, and the valve control pressure is fed back to the pump via port, causing the pump to swivel back towards V g min. Port T of the sequence valve and port T 1 of the pump must be connected back to tank (cooler). etting range for pressure control 50 315 bar When ordering, state in clear text the setting of the pressure control. Note: Any pressure relief valve included in the circuit to limit the max. pressure must be set to a cracking pressure at least 20 bar above the pressure control setting. The sequence valve and port plate must be ordered separately. equence valve: DZ5DP2-1X/315YMO21 (Mat.No. 900495604) Port plate: G 115/1 (Mat.No. 900424379) Characteristic DG Operating pressure pb in bar etting range 315 50 max min max. 10 bar Flow q v in L/min Circuit diagram DG (1) B (A) P A T V g min V g max A1 X3 T1 Position (1) is not included in the pump supply.

12/32 Bosch exroth AG A7VO E 92 202/03.06 D Pressure Control D Pressure control with load sensing Characteristic D The load sensing control is a flow control option that operates as a function of the load pressure to regulate the pump displacement to match the actuator flow requirement. The flow depends here on the cross section of the external sensing orifice (1) fitted between the pump outlet and the actuator. The flow is independent of the load pressure below the pressure cut-off setting and within the control range of the pump. The sensing orifice is usually a separately arranged load sensing directional valve (control block). The position of the directional valve piston determines the opening cross section of the sensing orifice and thus the flow of the pump. The load-sensing control compares pressure before and after the sensing orifice and maintains the pressure drop across the orifice - and therefore the pump flow - constant as a function of the orifice size. If the differential pressure Δp increases, the pump is swivelled back towards V g min and, if the Δp decreases the pump is swivelling out towards V g max until the pressure drop across the sensing orifice in the valve is restored. Δp orifice = p pump p actuator etting range for Δp 14 25 bar Operating pressure pb in bar etting range 350 max 50 min Circuit diagram D Flow q v in L/min X4 B (A) V g min V g max A1 (1) max. 10 bar tandard setting 18 bar (please state in clear text when ordering) The stand-by pressure in zero stroke operation (sensing orifice plugged) is slightly above the Δp setting. (1) The sensing orifice (control block) is not included in the pump supply. X3 T1 Position (1) is not included in the pump supply.

E 92 202/03.06 A7VO Bosch exroth AG 13/32 HD Hydraulic Control, Pilot Pressure elated With the pilot pressure related control the pump diplacement is adjusted in proportion to the pilot pressure applied to port X 1. Maximum permissible pilot pressure p t max = 40 bar Control from V g min to V g max. Circuit diagram HD X1 Y3 With increasing pilot pressure the pump swivels to a higher displacement B (A) etting range for start of control 4-15 bar When ordering, state in clear text the start of control. V g min A1 A control pressure of 40 bar is required to swivel the pump from its starting position V g min to V g max. The required control pressure is taken either from the operating pressure, or from the externally applied control pressure at the port. To ensure the control even at low operating pressure < 40 bar the port must be supplied with an external control pressure of approx. 40 bar. V g max X3 Characteristic HD1 Increase in pilot pressure V g min to V g max Δp = 10 bar 40 35 Pilot pressure pt in bar etting range 30 25 20 15 10 4 0 0,2 0,4 0,6 0,8 1,0 V g min Displacement V g max Characteristic HD2 Increase in pilot pressure V g min to V g max Δp = 25 bar 40 35 Pilot pressure pt in bar etting range 30 25 20 15 10 4 0 0,2 0,4 0,6 0,8 1,0 V g min Displacement V g max

14/32 Bosch exroth AG A7VO E 92 202/03.06 HD Hydraulic Control, Pilot Pressure elated HD.G Hydraulic control, for pressure cut-off, remote controlled A sequence valve with port plate takes over the function of the pressure cut-off. The valve is mounted separate from the pump, and the simple piping length should not exceed 5 m. High pressure is supplied from the pump to the valve via port. The control pressure of the pump is directed to the valve via the port and led into the tank at port A located on the port plate of the sequence valve. In this case the pump is regulated to V g min in case of access of the set-point pressure value. etting range for pressure control 50 315 bar When ordering, state in clear text the setting of the pressure control. Note: The port A of the sequence valve must be connected back to tank (cooler). Any pressure relief valve included in the circuit to limit the max. pressure must be set to a cracking pressure at least 20 bar above the pressure control setting. The sequence valve and port plate must be ordered separately. equence valve: DZ5DP2-1X/315XYMO20 (Mat.No. 900490554) Port plate: G 115/1 (Mat.No. 900424379) Characteristic HD.G Operating pressure pb in bar etting range 315 50 max min max. 10 bar Circuit diagram HD.G X1 V g max V g min Position (1) is not included in the pump supply. Y3 B (A) Note The spring centering in the pilot control unit is not a safety device Through contamination in the control unit e.g. in hydraulic fluid, wear particles, or particles out of a system the valve spool can get stuck in an undefined position. In this case, the pump flow does not follow the command inputs of the machine operator anymore. Make sure that a proper emergency shut down function can bring the driven machine movements to a safe position immediately (e.g. stop). Adhere to the speci fi ed cleanliness level 20/18/15 (<90 C) or 19/17/14 (>90 C) to IO 4406. A1 X3 (1) P X A Flow q v in L/min

E 92 202/03.06 A7VO Bosch exroth AG 15/32 EP Electrical Control with Proportional olenoid With the electrical control with proportional solenoid, the pump displacement is adjusted proportionally to the solenoid current, resulting in a magnetic control force, acting directly onto the control spool that pilots the pump control piston. Characteristic EP 800 700 Control from V g min to V g max With increasing control current the pump swivels to a higher displacement. A control pressure of 40 bar is required to swivel the pump from its starting position V g min to V g max. The required control pressure is taken either from the operating pressure, or from the externally applied control pressure at the port. To ensure the control even at low operating pressure < 40 bar the port must be supplied with a external control pressure of approx. 40 bar. Control current I in ma 600 500 400 300 200 100 0 0,2 0,4 0,6 0,8 1,0 V g min Displacement V g max Note: Install pump with EP control in the fluid tank only when using mineral hydraulic fluids and an fluid temperature in the tank of max. 80 C. Circuit diagram EP Y3 To control the proportional solenoids the following electronic amplifi er and controller are available (also as to the Internet under www.boschrexroth.com/mobile-electronic): B (A) BODA controller C (E 95200) and application software V g min A1 Analog amplifier A (E 95230) By using an proportional amplifier control of swivel time is also possible. Technical data of solenoids V g max X3 EP Voltage 24 VDC (±20%) Control current EP.G see HD.G Electrical control, for pressure cut-off, remote controlled tart of control at V g min 200 ma End of control at V g max 600 ma Limiting current 0,68 A Nominal resistance (at 20 C) 19,5 Ω Dither frequency 100 Hz Duty cycle 100% Type of protection (HICHMANN) IP65 to DIN EN 60529 Note The spring centering in the pilot control unit is not a safety device Through contamination in the control unit e.g. in hydraulic fluid, wear particles, or particles out of a system the valve spool can get stuck in an undefined position. In this case, the pump flow does not follow the command inputs of the machine operator anymore. Make sure that a proper emergency shut down function can bring the driven machine movements to a safe position immediately (e.g. stop). Adhere to the specified cleanliness level 20/18/15 (<90 C) or 19/17/14 (>90 C) to IO 4406.

16/32 Bosch exroth AG A7VO E 92 202/03.06 nit Dimensions, ize 28 Power control Note: All control versions are shown with clockwise direction of rotation. Before finalizing your design, please request approved installation drawing. Dimensions in mm. 26 16 215 209 (A1) 207 T 1 45 45 92 ø100-0.022 ø62 13.4 max 25 Flange IO 3019-2 7 12 30' 198 209 (X3) 29 119 18 20 33 Y 118 ø125 ø11 118 View Y counter-clockwise rotation T 1 View Y clockwise rotation 71 49 79 60 52 T 1 50.8 ø19 24 ø38 69.9 A B 23.8 49 108.5 35.7

E 92 202/03.06 A7VO Bosch exroth AG 17/32 nit Dimensions, ize 28 haft ends Before finalizing your design, please request approved installation drawing. Dimensions in mm. Z plined shaft DIN 5480 W25x1,25x30x18x9g 19 6 P Parallel keyed shaft DIN 6885, A8x7x40 19 6 ø35 M8x1.25 1 ) 2 ) 43 15 ø25 +0.002 +0.015 M8x1.25 1 ) 2 ) 28 ø35 50 Ports A, B ervice line ports (high pressure series) AE J518 3/4 in fastening thread DIN 13 M10x1,5; 17 deep 2 ) uction port (standard series) AE J518 1 1/2 in fastening thread DIN 13 M12x1,75; 20 deep 2 ) Bearing flushing (plugged) DIN 3852 M16x1,5; 12 deep 100 Nm 2 ) Air bleed (plugged) DIN 3852 M18x1,5; 12 deep 140 Nm 2 ) High pressure (plugged) DIN 3852 M12x1,5; 12 deep 50 Nm 2 ) T 1 Pilot fluid drain (plugged, only D,..D.. open) DIN 3852 M12x1,5; 12 deep 50 Nm 2 ) Override (plugged) DIN 3852 M12x1,5; 12 deep 50 Nm 2 ) External control pressure (plugged) DIN 3852 M14x1,5; 12 deep 80 Nm 2 ) X 1 Pilot pressure DIN 3852 M14x1,5; 12 deep 80 Nm 2 ) 1 ) centering bore according to DIN 332 (thread according to DIN 13) 2 ) please observe the general notes for the max. tightening torques on page 32

18/32 Bosch exroth AG A7VO E 92 202/03.06 nit Dimensions, ize 28 D Power control with pressure cut-off Before finalizing your design, please request approved installation drawing. Dimensions in mm. D 236 124 108.5 D/DG Pressure control, remote controlled D 236 DG HD1/HD1G/HD2/HD2G Hydraulic control for pressure cut-off, remote controlled 216 EP/EPG Electrical control for pressure cut-off, remote controlled 216 Y3 76 (X3) 78 (A1) 153 77 92 (DG) 170 199 132 (D) 76 (X3) 78 (A1) 153 274 77 4.5 15 49 X 1 155 (X1) 159 (Y3) 187 (A1) 188 (X3) X 1 49 15 159 (Y3) 187 (A1) 188 (X3)

E 92 202/03.06 A7VO Bosch exroth AG 19/32 nit Dimensions, ize 55 Power control Note: All control versions are shown with clockwise direction of rotation Before finalizing your design, please request approved installation drawing. Dimensions in mm. 32 20 262 241(T1) 232 T 1 140 45 45 ø125-0.025 ø70 12 30' 35 12 35 36 Y ø160 ø13.5 150 14.6 max 31 Flange IO 3019-2 7.5 241 (A1) 242 (X3) 142 150 View Y counter-clockwise rotation View Y clockwise rotation 76 90 57 62 12 T 1 T 1 50.8 ø19 32 77.8 ø49 A B 23.8 42.9 49 100

20/32 Bosch exroth AG A7VO E 92 202/03.06 nit Dimensions, ize 55 haft ends Before finalizing your design, please request approved installation drawing. Dimensions in mm. Z plined shaft DIN 5480 W30x2x30x14x9g 28 9.5 P Parallel keyed shaft DIN 6885, A8x7x50 28 9.5 M12x1.75 1 ) 2 ) ø45 ø45 8 35 +0.015 ø30 +0.002 M12x1.75 1 ) 2 ) 33 60 Ports A, B ervice line ports (high pressure series) AE J518 3/4 in Fastening thread DIN 13 M10x1,5; 17 deep 2 ) uction port (standard series) AE J518 2 in Fastening thread DIN 13 M12x1,75; 20 deep 2 ) Bearing flushing (plugged) DIN 3852 M18x1,5; 12 deep 140 Nm 2 ) Air bleed (plugged) DIN 3852 M18x1,5; 12 deep 140 Nm 2 ) High pressure (plugged) DIN 3852 M14x1,5; 12 deep 80 Nm 2 ) T 1 Pilot fluid drain (plugged, only D,..D.. open) DIN 3852 M12x1,5; 12 deep 50 Nm 2 ) Override (plugged) DIN 3852 M14x1,5; 12 deep 80 Nm 2 ) External control pressure (plugged) DIN 3852 M14x1,5; 12 deep 80 Nm 2 ) X 1 Pilot pressure DIN 3852 M14x1,5; 12 deep 80 Nm 2 ) X 4 Load pressure DIN 3852 M14x1,5; 12 deep 80 Nm 2 ) 1 ) centering bore according to DIN 332 (thread according to DIN 13) 2 ) please observe the general notes for the max. tightening torques on page 32

E 92 202/03.06 A7VO Bosch exroth AG 21/32 nit Dimensions, ize 55 D Power control with pressure cut-off D 128 Before finalizing your design, please request approved installation drawing. Dimensions in mm. DH1 Power control with pressure cut-off, stroke limiter X 1 12 D 262 257 (X1) 252 (Y3) X 1 105 127 170 119 D/DG Pressure control, remote controlled 119 D Pressure control with load sensing D DG X 4 6 300 D 238 X 4 114 (DG) 135 (D) 141 151 HD1/HD1G/HD2/HD2G Hydraulic control for pressure cut-off, remote controlled 256 EP/EPG Electrical control for pressure cut-off, remote controlled 256 82 101 170 Y A 3 1 X 1 192 221 100 82 101 170 Y A 3 1 296 100 12 12 57 186 (X1) 190 (Y3) 209 (A1) 221 (X3) X 1 12 12 57 190 (Y3) 209 (A1) 221 (X3)

22/32 Bosch exroth AG A7VO E 92 202/03.06 nit Dimensions, ize 80 Before finalizing your design, please request approved installation drawing. Dimensions in mm. Power control Note: All control versions are shown with clockwise direction of rotation 287 270 (T1) 253 23 32 45 45 T 1 144 ø13.5 ø140-0.025 ø83 12 30' 37 17 38 40 Y ø180 165 157 165 7.5 14.6 max Flange IO 3019-2 31 265 (X3) 270 (A1) View Y clockwise rotation 80 102 View Y counter-clockwise rotation 62 22 70 64 T 1 T 1 57.2 ø25 34 ø62 88.9 A B 27.8 50.8 57 111

E 92 202/03.06 A7VO Bosch exroth AG 23/32 nit Dimensions, ize 80 haft ends Before finalizing your design, please request approved installation drawing. Dimensions in mm. Z plined shaft DIN 5480 W35x2x30x16x9g 28 9.5 P Parallel keyed shaft DIN 6885, A10x8x56 28 9.5 M12x1.75 1 ) 2 ) ø50 38 ø50 8 40 +0.018 ø35 +0.002 M12x1.75 1 ) 2 ) 70 Ports A, B ervice line ports (high pressure series) AE J518 1 in Fastening thread DIN 13 M12x1,75; 17 deep 2 ) uction port (standard series) AE J518 2 1/2 in Fastening thread DIN 13 M12x1,75; 17 deep 2 ) Bearing flushing (plugged) DIN 3852 M18x1,5; 12 deep 140 Nm 2 ) Air bleed (plugged) DIN 3852 M18x1,5; 12 deep 140 Nm 2 ) High pressure (plugged) DIN 3852 M16x1,5; 12 deep 100 Nm 2 ) T 1 Pilot fluid drain (plugged, only D,..D.. open) DIN 3852 M12x1,5; 12 deep 50 Nm 2 ) Override (plugged) DIN 3852 M16x1,5; 12 deep 100 Nm 2 ) External control pressure (plugged) DIN 3852 M14x1,5; 12 deep 80 Nm 2 ) X 1 Pilot pressure DIN 3852 M14x1,5; 12 deep 80 Nm 2 ) X 4 Load pressure DIN 3852 M14x1,5; 12 deep 80 Nm 2 ) 1 ) centering bore according to DIN 332 (thread according to DIN 13) 2 ) please observe the general notes for the max. tightening torques on page 32

24/32 Bosch exroth AG A7VO E 92 202/03.06 nit Dimensions, ize 80 D Power control with pressure cut-off D Before finalizing your design, please request approved installation drawing. Dimensions in mm. DH1 Power control with pressure cut-off, stroke limiter 290 14 284 (X1) X 279 (Y3) 1 D X 1 132 116 138 182 130 130 D/DG Pressure control, remote controlled D DG D Pressure control with load sensing 6 327 X 4 D 265 X 4 125 (DG) 139 (D) 151 161 HD1/HD1G/HD2/HD2G Hydraulic control for pressure cut-off, remote controlled 287 EP/EPG Electrical control for pressure cut-off, remote controlled 287 X 1 92 113 187 209 240 114 92 113 187 315 114 22 14 62 207 (X1) 212 (Y3) 237 (A1) 241 (X3) X 1 22 14 62 212 (Y3) 237 (A1) 241 (X3)

E 92 202/03.06 A7VO Bosch exroth AG 25/32 nit Dimensions, ize 107 Power control Note: All control versions are shown with clockwise direction of rotation Before finalizing your design, please request approved installation drawing. Dimensions in mm. 25 40 307 286 (T1) 272 45 45 ø160-0.025 ø90 12 30' 41 18 Y 170 37 46 150 ø200 ø17.5 190 14.6 max 39 Flange IO 3019-2 7.5 284 (X3) 289 (A1) 190 View Y clockwise rotation View Y counter-clockwise rotation 88 105 70 74 22 72 T 1 T 1 57.2 ø25 36 ø62 88.9 A B 27.8 50.8 55 115

26/32 Bosch exroth AG A7VO E 92 202/03.06 nit Dimensions, ize 107 haft ends Before finalizing your design, please request approved installation drawing. Dimensions in mm. Z plined shaft DIN 5480 W40x2x30x18x9g 28 9.5 P Parallel keyed shaft DIN 6885, A12x8x63 28 9.5 M12x1.75 1 ) 2 ) ø60 43 ø60 8 45 +0.018 ø40 +0.002 M12x1.75 1 ) 2 ) 80 Ports A, B ervice line ports (high pressure series) AE J518 1 in Fastening thread DIN 13 M12x1,75; 17 deep 2 ) uction port (standard series) AE J518 2 1/2 in Fastening thread DIN 13 M12x1,75; 17 deep 2 ) Bearing flushing (plugged) DIN 3852 M18x1,5; 12 deep 140 Nm 2 ) Air bleed (plugged) DIN 3852 M18x1,5; 12 deep 140 Nm 2 ) High pressure (plugged) DIN 3852 M16x1,5; 12 deep 100 Nm 2 ) T 1 Pilot fluid drain (plugged, only D,..D.. open) DIN 3852 M12x1,5; 12 deep 50 Nm 2 ) Override (plugged) DIN 3852 M16x1,5; 12 deep 100 Nm 2 ) External control pressure (plugged) DIN 3852 M14x1,5; 12 deep 80 Nm 2 ) X 1 Pilot pressure DIN 3852 M14x1,5; 12 deep 80 Nm 2 ) X 4 Load pressure DIN 3852 M14x1,5; 12 deep 80 Nm 2 ) 1 ) centering bore according to DIN 332 (thread according to DIN 13) 2 ) please observe the general notes for the max. tightening torques on page 32

E 92 202/03.06 A7VO Bosch exroth AG 27/32 nit Dimensions, ize 107 D Power control with pressure cut-off D 138 Before finalizing your design, please request approved installation drawing. Dimensions in mm. DH1 Power control with pressure cut-off, stroke limiter X 1 18 D 309 300 (X1) 295 (Y3) X 1 122 144 189 134 134 D/DG Pressure control, remote controlled D Pressure control with load sensing D DG X 4 D 352 290 X4 154 167 132 (DG) 145 (D) HD1/HD1G/HD2/HD2G Hydraulic control for pressure cut-off, remote controlled 306 EP/EPG Electrical control for pressure cut-off, remote controlled 306 X 1 100 119 199 221 252 122 100 119 199 327 122 22 18 70 220 (X1) 225 (Y3) 254 (A1) 259 (X3) X 1 22 18 70 225 (Y3) 254 (A1) 259 (X3)

28/32 Bosch exroth AG A7VO E 92 202/03.06 nit Dimensions, ize 160 Before finalizing your design, please request approved installation drawing. Dimensions in mm. Power control Note: All control versions are shown with clockwise direction of rotation 349 328 (T1) 310 28 40 T 1 160 45 45 ø180-0.025 ø100 12 30' 47 55 46 Y 193 27 ø224 ø17.5 210 14.9 max 39 7.5 210 Flange IO 3019-2 327 (X3) 331 (A1) View Y clockwise rotation 100 126 View Y counter-clockwise rotation 78 22 84 T 1 T 1 66.7 ø32 40 ø75 106.4 A B 31.8 66 61.9

E 92 202/03.06 A7VO Bosch exroth AG 29/32 nit Dimensions, ize 160 haft ends Before finalizing your design, please request approved installation drawing. Dimensions in mm. Z plined shaft DIN 5480 W45x2x30x21x9g 36 12 P Parallel keyed shaft DIN 6885, A14x9x70 36 12 M16x2 1 ) 2 ) ø70 48.5 ø70 8 50 +0.018 ø45 +0.002 M16x2 1 ) 2 ) 90 Ports A, B ervice line ports (high pressure series) AE J518 1 1/4 in Fastening thread DIN 13 M14x1,5; 19 deep 2 ) uction port (standard series) AE J518 3 in Fastening thread DIN 13 M16x1,5; 24 deep 2 ) Bearing flushing (plugged) DIN 3852 M22x1,5; 14 deep 210 Nm 2 ) Air bleed (plugged) DIN 3852 M26x1,5; 16 deep 230 Nm 2 ) High pressure (plugged) DIN 3852 M16x1,5; 12 deep 100 Nm 2 ) T 1 Pilot fluid drain (plugged, only D,..D.. open) DIN 3852 M12x1,5; 12 deep 50 Nm 2 ) Override (plugged) DIN 3852 M16x1,5; 12 deep 100 Nm 2 ) External control pressure (plugged) DIN 3852 M14x1,5; 12 deep 80 Nm 2 ) X 1 Pilot pressure DIN 3852 M14x1,5; 12 deep 80 Nm 2 ) X 4 Load pressure DIN 3852 M14x1,5; 12 deep 80 Nm 2 ) 1 ) centering bore according to DIN 332 (thread according to DIN 13) 2 ) please observe the general notes for the max. tightening torques on page 32

30/32 Bosch exroth AG A7VO E 92 202/03.06 nit Dimensions, ize 160 D Power control with pressure cut-off D Before finalizing your design, please request approved installation drawing. Dimensions in mm. DH1 Power control with pressure cut-off, stroke limiter 351 19 340 (X1) 334 (Y3) X 1 D X 1 150 140 162 207 145 145 D/DG Pressure control, remote controlled D Pressure control with load sensing 392 X 4 D 329 X 4 150 (DG) 155 (D) 172 185 D DG HD1/HD1G/HD2/HD2G Hydraulic control for pressure cut-off, remote controlled 348 EP/EPG Electrical control for pressure cut-off, remote controlled 348 120 139 X 3 A X 1 1 137 225 248 278 120 139 225 353 137 22 19 78 249 (X1) 253 (Y3) 290 (A1) 294 (X3) X 1 22 19 78 253 (Y3) 290 (A1) 294 (X3)

E 92 202/03.06 A7VO Bosch exroth AG 31/32 Installation Notes General During commissioning and operation, the axial piston unit must be filled with hydraulic fluid and air bled. This is also to be observed following a relatively long standstill as the system may empty via the hydraulic lines. The leakage fluid chamber is internally connected to the suction chamber. A leakage fluid line to the tank is not required. Exception: Operation with pressure control or pressure cut-off. In all operating states, the suction line must flow into the tank below the minimum fluid level. The minimum suction pressure at port must not fall below 0,8 bar absolute. Installation position As to the examples mentioned below. Further installation positions are possible upon consultation. Installation below the tank (standard) Pump below minimum fluid level in tank. ecommendation installation position: 1 and 2. 1 2 1 2 2 1 3 4 2 1 1 2 Installation position Air bleed Filling 1 1 2 2 3 1, 2 4

32/32 Bosch exroth AG A7VO E 92 202/03.06 General Notes The A7VO pump is designed to be used in open circuits. Project planning, assembly and commissioning of the pump require the involvement of trained personnel. The working and functional ports are only designed to accommodate hydraulic piping. There is a danger of burns from the pump and especially the solenoids during and shortly after operation. uitable safety precautions, e.g. protective clothing plan. The characteristic curve may shift depending on the operating status (operating pressure, fluid temperature) of the pump. Tightening torques: - The tightening torques specified in this data sheet are maximum values and may not be exceeded (maximum value for screw thread). Manufacturer specifications for the max. permissible tightening torques of the used fittings must be observed! - For DIN 13 fastening screws we recommend checking the tightening torque individually according to VDI 2230 Edition 2003. The data and information contained herein must be adhered to. Bosch exroth AG Hydraulics Product egment Axial Piston nits Elchingen Plant Glockeraustrasse 2 89275 Elchingen, Germany Phone +49 (0) 73 08 82-0 Facsimile +49 (0) 73 08 72 74 info.brm-ak@boschrexroth.de www.boschrexroth.com/axial-piston-pumps This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch exroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging. ubject to change.