DATA SHEET Automatic Sustainable Controller, ASC Plant Management

Similar documents
ASC SWITCHBOARD DATA SHEET

DATA SHEET Genset Control Unit, GCU 100

Automatic Genset Controller, AGC-4 Display readings Push-button functions Alarm handling Log list

Advanced Genset Controller, AGC 200 Display readings Push-button functions Alarm handling Log list

magellan solar export control solutions Magellan Power Solar Gate

Automatic Genset Controller, AGC-3 Functional description Display unit and menu structure PID-controller Procedure for parameter setup Parameter list

Options G4, G5 and G8 Power management Functional description Display units Power management setup Power management functions Parameter lists

Green approach to fuel savings

magellan solar export control solutions Magellan Power Solar Gate

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

Magellan Utility Scale Energy Storage

Option M4 Engine control and protection Functional description Modes and sequences General product information PID controller Additional functions

Compact Energy Storage Module. Modular Systems, EPDS. Product overview

/ The personal storage solution for 24H sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

ABB central inverters ULTRA-750/1100/ kW to 1560kW

NOT RECOMMENDED FOR NEW DESIGNS. Wind display type WSDI-2 DATA SHEET. Watertight. Displays

Wind display type WSDI-2 DATA SHEET

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A

Technical Information Control of the Active Power Feed-In at the Grid-Connection Point with the SMA CLUSTER CONTROLLER

DEIF A/S. Application Notes. Automatic Gen-set Controller. Single generator set. Automatic mains failure. Parallel with mains (grid)

Delta Products VFD CP2000 Bypass Control Packages.

MAY 2018 Improving CAPEX and OPEX of PV power plants with high power string inverters Gianluca Pieralli (Regional Sales Manager Lat Am) / Gianluca

Application. Battery. Public Grid GS HYBRID INVERTER

Designer s Reference Handbook. Automatic Gen-set Controller/GS Multi-line K SW version 2.40.X. Display unit and menu structure

CATALOG. ABB micro drives ACS55, 0.18 to 2.2 kw

ABB central inverters PVS to 2000 kva

1 EASY COMMISSIONING GUIDE FRONIUS PV-SYSTEM CONTROLLER

Advanced Genset Controller, AGC 200 Functional description Display menu structure PID controller Procedure for parameter setup

DATA SHEET WSS 700 and WSS 750 High performance wind sensors

ABB central inverters PVS to 2091 kva

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

ABB string inverters UNO-DM-1.2/2.0/3.3/4.0/4.6/5.0-TL-PLUS 1.2 to 5.0 kw

ABB string inverters UNO-DM-1.2/2.0/3.3/4.0/4.6/5.0-TL-PLUS-Q 1.2 to 5.0 kw

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

Residential Energy Storage System SH 5K

Low voltage AC drives. ABB component drives ACS to 2.2 kw / 0.25 to 3 hp Catalog

Power Switching Devices

Feed-in management with Solar-Log

Battery Care the new Battery Charger Philosophy Battery Charger and Battery Tester. Charge & Testing. Integrated Electronic Solutions

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

Delomatic 400 (DM 400) based Gas Engine and Combined Heat and Power (CHP) Control and Management System

Low voltage AC drives

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

ABB central inverters PVS to 1000 kw

ILA2D572TC1F0 integrated drive ILA with servo motor V - DeviceNet - indus connector

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

Mains. Great performances. Attractive coloured display. PLC functions inbuilt. Several I/O with possibility of expansion modules

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

ABB central inverters PVS to 1000 kw

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

Energetic independence

DBC-1 DEIF Battery Charger

THREE-PHASE. FRONIUS ENERGY PACKAGE / The personal storage solution for 24 hours of sun. EFFICIENT FLEXIBLE REVOLUTIONARY

9.1.4 Troubleshooting of Faults in LCD Screen

ILE2K661PC1A1 brushless dc motor V- EtherNet/IP interface - L = 174 mm- 18:1

Power Conversion System The Best Technology for your photovoltaic and storage system

Commercial 1000VDC String Inverter XGI Installation and Operation Guide Models: XGI XGI

ABB - DMPC PG Solar, Nov 2016 ABB: a leading company in solar The most comprehensive value proposition

Honeywell CORE Drive FEATURES APPLICATION SPECIFICATION DATA

Solar inverter AX-series

MEC 310 GENSET CONTROLLER

GS2 Series - Introduction

Greater reliability and flexibility for large solar installations. Conext Core XC-NA series central inverters

TCM-2 Thyristor DATA Control SHEETModule DATA SHEET. TCM-2 Thyristor Control Module

FRONIUS SNAPINVERTERS SMARTER, LIGHTER, MORE FLEXIBLE

SMA COMMERCIAL PRODUCTS SUNNY TRIPOWER CORE1. Stands on its own. Up to 60 % faster installation for commercial PV systems

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

High performance Vector Control. Ratings. System configuration

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

L kw Distributed Energy Storage System Unit (SU50)

THYRO-PX SERIES DIGITAL THYRISTOR SCR POWER CONTROLLER UP TO 2900 AMPS

/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

Residential Energy Storage System SH5K PV ESS

D509E. Manual Motor - Starters

Photovoltaics. MPI Hybrid Series

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

TEST REPORT DIN V VDE V

Lexium integrated drives

TEST REPORT DIN V VDE V

Datasheet. Pitch Motor PMSM SP260B8

Datasheet. Pitch Motor PMSM SP190C8

ILE2T661PB1A3 brushless dc motor V - Modbus TCP interface - L = 174 mm - 54:1

Safe, reliable, long lasting Lithium Iron Phosphate battery. Next generation capture and release technology. Increased efficiency for greater savings

Datasheet. Pitch Motor PMSM SP190F8

FRONIUS ENERGY PACKAGE

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

EPS/ELA-Series User Manual EPS/ELA 250W

Galaxy VM. From 160 kva to 1000 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity. schneider-electric.

Sunny Tripower CORE1.

Energy Storage System for Home

SolarMax MT series The all-rounder for trade and industry

ThermoPro TM Series TP10

Technical Data. Low Voltage Regulation System LVRSys. Flexible solution for power utilities. Voltage stabilization for industrial grids

Energy Storage System for Home. High Efficiency - Peak efficiency 97.3% Bi-directional DC-DC converter

Guidelines for the Design of Residential and Community Level Storage Systems Combined with Photovoltaics (PV)

Magellan Stand Alone Power System (1P) Magellan Renewables Range

SOL-ARK 8K. More Affordable: 5-15% less solar panels & 5-20% less batteries than others! World s Most Efficient Battery Inverter

Transcription:

DATA SHEET Automatic Sustainable Controller, ASC Plant Management PV/diesel applications Self-consumption, IPP applications Meteorological data measuring Inverter monitoring SunSpec master and slave interface DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com www.deif.com Document no.: 4921240459D SW version: 1.02.0 or later

1. General information 1.1. Automatic Sustainable Controller, Plant Management...3 2. Application information 2.1. ASC PM Solar...4 2.1.1. Basic rule of operation...4 2.1.2. Minimum genset load...4 2.1.3. Spinning reserve...4 2.1.4. Power ramp...4 2.2. Application types...4 2.2.1. Stand-alone applications...4 2.2.2. Power management applications...6 2.3. Inverter interfacing...8 2.4. Weather station...9 2.5. Monitoring...10 3. Display layout 3.1. ASC PM Solar display...11 4. Hardware, software and options 4.1. Hardware, software and options, ASC PM controller...12 5. Technical information 5.1. Specifications and dimensions...15 5.1.1. Technical specifications...15 5.1.2. Unit dimensions in mm (inches)...18 6. Ordering information 6.1. Order specifications and disclaimer...19 6.1.1. Order specifications...19 6.1.2. Disclaimer...19 DEIF A/S Page 2 of 19

General information 1. General information 1.1 Automatic Sustainable Controller, Plant Management The Automatic Sustainable Controller, Plant Management (ASC PM) is a controller designed to serve as a link between sustainable power plants and genset plants, combining them so they work as one common hybrid plant. The concept of the ASC PM is to maximise sustainable power penetration, depending on the total load demand to the hybrid without compromising constraints such as minimum genset load demand. DEIF A/S Page 3 of 19

Application information 2. Application information 2.1 ASC PM Solar The ASC PM Solar is the variant designed for PV control, and it enables integration of PV power and genset power. 2.1.1 Basic rule of operation The PV plant is handled as a base loading power- and reactive power provider, not as a voltage- and frequency provider. Therefore, the ASC PM only operates the PV in case either utility or a genset constitutes a grid to which the PV can dispatch power. 2.1.2 Minimum genset load A minimum genset load constraint is available in the ASC PM. The constraint applies in off-grid operation only. This constraint will cause the PV penetration to decrease if it is compromised. This is to secure a certain amount of load on the gensets and in this way eliminate the risk of reverse power situations and impure combustion and exhaust problems. In grid-tied operation the minimum genset load must be handled locally by each individual genset. 2.1.3 Spinning reserve Settings for determination of the necessary spinning reserve in the genset plant are included. The spinning reserve is towards the power that is produced by the PV plant. Hence the settings determine how much spinning reserve the genset plant should keep to compensate for a potential decrease in PV production. Spinning reserve applies to power management applications only. 2.1.4 Power ramp To avoid potential oscillations in the hybrid, the ASC PM provides both active and reactive power ramp-up/ ramp-down functionality. This is to be able to control the rate of change of power references for the PV plant and thereby provide the genset plant time to adapt to the changes in the PV production. 2.2 Application types The ASC PM supports two types of applications: Stand-alone applications Power management applications The ASC PM comes with the maximum capability built in, which means that the ASC PM can do both types of applications without any program or firmware change. 2.2.1 Stand-alone applications In stand-alone solutions, the ASC PM does not have much information about the surrounding environment in which it is located. Based on transducer power readings and hardwired feedbacks alone, the ASC PM determines the power references to the PV plant. This approach can be applied to integrate PV power in already commissioned genset plants, whether they are equipped with DEIF controllers or not. The ASC PM can do both pure off-grid, pure grid-tied and a combination of the two. DEIF A/S Page 4 of 19

G ASC Plant Management data sheet Application information Mains Transducer P Q Mains Transducer P Mains breaker (MB) Controller Busbar Consumers Transducer Transducer Q Busbar P P Display Mains breaker (MB) Display Transducer P Transducer P Q Q Consumers Q Q Display Controller Controller ASC Generator breaker (GB 1) Generator breaker (GB 2) PV breaker (PVB) PV breaker (PVB) ASC Generator breaker (GB 1) Controller Generator breaker (GB 2) Controller PV breaker (PVB) ASC G G G Diesel generator set 1 Diesel generator set 2 PV Diesel generator set 1 Diesel generator set 2 PV PV The maximum capability of the stand-alone applications is 16 gensets, one mains and one PV plant. The ASC PM supports four different plant modes: Island mode Fixed power mode Mains power export mode Peak shaving mode Island mode: When the ASC PM is in island mode and only gensets are connected to the busbar, the PV power references are determined on the basis of genset power and reactive power transducer readings alone. The active power reference is maximised to the limit dictated by the minimum genset load constraint. If the gensets are either in reverse power state or being overloaded, the power ramp will be skipped. For reactive power, it can be selected whether the PV plant should contribute with reactive power production to have the PV plant match the same cos phi as the genset plant, or whether the PV plant should not contribute with reactive power at all. In any case, if gensets are driven outside of their capability, the PV plant will pick up the surplus of reactive power. If the PV plant itself is driven outside of its capability, it can be selected whether to prioritise active or reactive production. Fixed power mode: When the ASC PM is in fixed power mode and either mains or genset is connected to the busbar, the PV power reference is determined by the fixed power reference setting in the ASC PM. If mains is connected to busbar, the reactive power reference is determined by the reactive power reference setting in the ASC PM and may depend on the mains reactive power transducer reading, if the selected reactive reference method dictates it. The ASC PM can take in external active and reactive power references. The references can be applied as hardwired signals or via communication. This makes the ASC PM suitable for IPP applications as well. If only gensets are connected, the minimum genset load constraint will be observed and power ramps will be skipped if the gensets are either in reverse power state or being overloaded. It can be selected whether the PV plant should contribute with reactive power production to have the PV plant match the same cos phi as the genset plant, or whether the PV plant should not contribute with reactive power at all. In any case, if gensets are driven outside of their capability, the PV plant will pick up the surplus of reactive power. If the PV plant itself is driven outside of its capability, it can be selected whether to prioritise active or reactive production. DEIF A/S Page 5 of 19

Application information Mains power export and peak shaving mode: When the ASC PM is in mains power export or peak shaving mode and a mains is connected to the busbar, the PV power reference is determined by a combination of reference setting in the ASC PM and the mains power transducer reading. The reactive power reference is determined by the reactive power reference setting in the ASC PM and may depend on the mains reactive power transducer reading, if the selected reactive reference method dictates it. When the mains power export mode is used, the ASC PM is able to keep both zero active power and zero reactive power across the point of connection. This makes the ASC PM suitable for self-consumption applications as well. If only gensets are connected, the minimum genset load constraint will be observed and power ramps will be skipped if the gensets are in reverse power state. It can be selected whether the PV plant should contribute with reactive power production to have the PV plant match the same cos phi as the genset plant, or whether the PV plant should not contribute with reactive power at all. In any case, if gensets are driven outside of their capability, the PV plant will pick up the surplus of reactive power. If the PV plant itself is driven outside of its capability, it can be selected whether to prioritise active or reactive production. The ASC PM can be operated in Auto mode or in Semi mode. Auto mode: When the ASC PM is in auto mode, it can be started if the PVB is closed by means of the auto start/stop input, or via auto start/stop Modbus commands. The PVB will be closed if either mains or any genset is connected to the busbar, applying suitable voltage and frequency. Semi mode: When the ASC PM is in semi mode, the PVB can be opened/closed manually by means of the ASC PM display buttons, or remotely via digital inputs or Modbus commands. If the PVB is closed, and if either mains or any genset is connected to the busbar, applying suitable voltage and frequency, the PV plant can be started/ stopped manually by means of the ASC PM display buttons, or remotely via digital inputs or Modbus commands. 2.2.2 Power management applications In the DEIF power management solution, the ASC PM is fully integrated in the DEIF Application Configuration and SuperVision PC tool. The ASC PM is connected to the CAN bus that constitutes the internal DEIF power management communication link. For that reason, this approach is only applicable if the genset plant is equipped with AGC PM controllers from DEIF. The DEIF power management system fully integrates the PV plant and the genset plant. The ASC PM can do both pure off-grid, pure grid-tied and a combination of the two. The maximum capability of the power management applications is 32 gensets/mains and eight PV plants. DEIF A/S Page 6 of 19

Application information The ASC PM supports five different plant modes: Island mode Fixed power mode Mains power export mode Peak shaving mode Power management mode Island mode: The same functionality as described in the paragraph "Stand-alone applications", except that the power and reactive power data from gensets and mains are received on the internal communication link. Fixed power mode: The same functionality as described in the paragraph "Stand-alone applications", except that the power and reactive power data from gensets and mains are received on the internal communication link. Mains power export and peak shaving mode: The same functionality as described in the paragraph "Stand-alone applications", except that the power and reactive power data from gensets and mains are received on the internal communication link. Power management mode: When the ASC PM is in power management mode, the overall mode is determined by the genset plant. It will follow the mode of the mains unit(s) if such is (are) present in the application, or - if not - it will be forced into island mode. In case only gensets are connected to the busbar, the PV references are determined on the basis of genset power and reactive power data received on the internal communication link. The active power reference is maximised to the limit dictated by the minimum genset load constraint. If the gensets are either in reverse power state or being overloaded, the power ramp will be skipped. For reactive power, it can be selected whether the PV plant should contribute with reactive power production to have the PV plant match the same cos phi as the genset plant, or whether the PV plant should not contribute with reactive power at all. In any case, if gensets are driven outside of their capability, the PV plant will pick up the surplus of reactive power. If the PV plant itself is driven outside of its capability, it can be selected whether to prioritise active or reactive production. If mains is connected to the busbar, the PV power reference is received from the genset plant via the internal communication link. The reactive power reference is determined by the reactive power reference setting in the ASC PM and may depend on the mains reactive power, if the selected reactive reference method dictates it. The reactive power reference can also be received from the genset plant if this is preferred. The AGC PM Mains can take in external active and reactive power references. The references can be applied as hardwired signals or via communication. This makes the system suitable for IPP applications as well. When the mains power export mode is used in the AGC PM Mains, it enables the system to keep zero power across the point of connection. This makes the system suitable for self-consumption applications as well. The ASC PM can be operated in Auto mode or in Semi mode. Auto mode: When the ASC PM is in auto mode, it will close the PV breaker and start the PV plant whenever suitable voltage and frequency are present on the busbar and: at least one genset in auto mode is connected to the busbar, or a mains is connected to the busbar and auto start is applied on the AGC PM mains unit. DEIF A/S Page 7 of 19

Application information Semi mode: When the ASC PM is in semi mode, the PVB can be opened/closed manually by means of the ASC PM display buttons, or remotely via digital inputs or Modbus commands. If the PVB is closed, and if either mains or any genset is connected to the busbar, applying suitable voltage and frequency, the PV plant can be started/ stopped manually by means of the ASC PM display buttons, or remotely via digital inputs or Modbus commands. 2.3 Inverter interfacing The ASC PM offers protocol interface to the inverters listed below: FSC SMA DEIF Open SunSpec Generic SunSpec SMA SunSpec Fronius ConextCL Schneider Electric TRIO ABB PRO-33 ABB PVS800 ABB E-series Gamesa Electric Sungrow 10-60SG Delta RPI Huawei SUN2000 8-28 Huawei SUN2000 33-40 Huawei smart-logger Goodwe DT series Cluster controller SMA imars BG series INVT All the listed interfaces are Modbus-based. Interfaces where the ASC PM serves as the slave are available both as Modbus RTU (requires option H2) and as Modbus TCP. Interfaces where the ASC PM serves as the master are available as Modbus RTU only (requires option H2). For Modbus TCP interfacing, an external Modbus RTU to Modbus TCP gateway such as HD67510 from ADFWeb is required. FSC SMA is a protocol designed for interfacing to the Fuel Save Controller provided by SMA Solar Technology AG. The ASC PM serves as the slave. DEIF Open is a protocol designed by DEIF, where the ASC PM serves as the slave. SunSpec Generic is a generic implementation of the SunSpec standardised protocol. It enables interfacing to any inverter, supporting both monitoring and control via SunSpec. When selected, the ASC PM will initially identify the SunSpec map in the inverter before it goes into normal operation. The ASC PM serves as the master. SunSpec SMA is a protocol where the SunSpec map is preset according to the maker-specific protocol and the ASC PM will not need to initially identify it, as opposed to the SunSpec Generic. The ASC PM serves as the master. DEIF A/S Page 8 of 19

Application information SunSpec Fronius is a protocol where the SunSpec map is preset according to the maker-specific protocol and the ASC PM will not need to initially identify it, as opposed to the SunSpec Generic. The ASC PM serves as the master. ConextCL Schneider Electric is a protocol designed for interfacing to the ConextCL inverter series provided by Schneider Electric. The ASC PM serves as the master. TRIO ABB is a protocol designed for interfacing to the TRIO inverter series provided by ABB. The ASC PM serves as the master. PRO-33 ABB is a protocol designed for interfacing to the PRO-33 inverter provided by ABB. The ASC PM serves as the master. PVS800 ABB is a protocol designed for interfacing to the PVS800 inverter series provided by ABB. The ASC PM serves as the master. Sungrow 10-60SG is a protocol designed for interfacing to the string inverter series provided by Sungrow. The ASC PM serves as the master. Delta RPI is a protocol designed for interfacing to the RPI inverter series provided by Delta. The ASC PM serves as the master. Huawei 8-28 is a protocol designed for interfacing to the 8-28 string inverter series provided by Huawei. The ASC PM serves as the master. Huawei 33-40 is a protocol designed for interfacing to the 33-40 string inverter series provided by Huawei. The ASC PM serves as the master. Huawei smart-logger is a protocol designed for interfacing to the smart-logger provided by Huawei. The ASC PM serves as the master. Goodwe DT series is a protocol designed for interfacing to the DT string inverter series provided by Goodwe. The ASC PM serves as the master. Cluster controller SMA is a protocol designed for interfacing to the STP inverter series from SMA. The ASC PM serves as the master. imars BG series INVT is a protocol designed for interfacing to the imars BG string inverter series provided by INVT. The ASC PM serves as the master. In addition to applying the active and reactive control references, the ASC PM can be set up to poll data from the inverters as well. The ASC PM can include a maximum of 42 inverters in its monitoring scheme. The polled data is made available in a designated Modbus map for a SCADA system to read out. 2.4 Weather station The ASC PM offers the possibility of connecting sensors for weather-related measurements such as Plane of Array irradiation sensors, Back of Module temperature sensors, and so on. Based on these readings, the ASC PM will calculate the instantaneous maximum power that can be generated by the PV plant. If the circumstances dictate that the ASC PM curtails the PV power production, throttle counters will increase and thus reveal the amount of unutilised PV power. The readings are presented in the display and are available via Modbus for a SCADA system to read out. DEIF A/S Page 9 of 19

Application information 2.5 Monitoring The ASC PM already offers Modbus slave functionality with a substantial proprietary protocol, including the inverter monitoring data and weather-related measurements described above. In addition to the proprietary protocol, a SunSpec map has been added to provide a standardised Modbus slave interface to PV SCADA systems. In the SunSpec map, the complete PV plant is treated as an entity. Even though the PV plant may consist of multiple string inverters, it will be aggregated power contribution from each inverter that gives the total PV production which can be read out from the ASC PM SunSpec map. The following SunSpec models are included in the SunSpec Slave support: C001: Common model I103: Inverter model I120: Name plate model I121: Inverter controls basic settings model I122: Inverter controls extended measurements and status model I123: Immediate control model E302: Irradiation model E303: Back of module temperature model E307: Base meteorological model End model DEIF A/S Page 10 of 19

Display layout 3. Display layout 3.1 ASC PM Solar display DEIF A/S Page 11 of 19

Hardware, software and options 4. Hardware, software and options 4.1 Hardware, software and options, ASC PM controller 1 2 3 4 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 CAN A CAN B Ethernet Ethernet Service port Display 9 Power Self check ok Alarm inhibit 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 5 6 7 8 1 : The numbers in the drawing above refer to the slot numbers indicated in the table below. DEIF A/S Page 12 of 19

Hardware, software and options Slot # Option/standard Description 1 Terminal 1-28, power supply Standard 8 to 36 V DC supply, 11 W; 1 status output relay; 5 relay outputs; 2 pulse outputs (kwh, kvarh or configurable open collector outputs); 5 digital inputs 2 Terminal 29-36, communication H2 Modbus RTU (RS-485). Can work as slave or as master for inverter comm. M13.2 7 binary inputs M14.2 4 relay outputs 3 Terminal 37-64, inputs/outputs Standard 13 digital inputs; 4 relay outputs 4 Terminal 65-72, inputs/outputs E2 2 0(4) to 20 ma outputs, transducer M13.4 7 binary inputs M14.4 4 relay outputs 5 Terminal 79-89, AC measuring Standard 3 PV voltage; 3 busbar voltage 6 Terminal 90-97, inputs/outputs F1 2 0(4) to 20 ma outputs, transducer M13.6 7 digital inputs M14.6 4 relay outputs M15.6 4 4 to 20 ma inputs 7 Terminal 98-125, communication, inputs/outputs Standard 8 to 36 V DC supply; 3 multi-inputs; 7 digital inputs; 4 relay outputs Power management communication, CAN port A and B 8 Terminal 126-133, inputs/outputs H2.8 Modbus RTU (RS-485). Can work as slave or as master for power meter comm. M13.8 7 digital inputs M14.8 4 relay outputs M15.8 4 4 to 20 ma inputs DEIF A/S Page 13 of 19

Hardware, software and options Slot # Option/standard Description 9 Terminal 73-78, LED I/F AC measuring Standard 3 PV current; Modbus TCP/IP Standard accessories AOP-1 DU-2 Additional options W1 W2 W3 One-year extended warranty Two-year extended warranty Three-year extended warranty There can only be one hardware option in each slot. For example, it is not possible to select option H2 and option M13.2 at the same time, because both options require a PCB in slot #2. DEIF A/S Page 14 of 19

Technical information 5. Technical information 5.1 Specifications and dimensions 5.1.1 Technical specifications Accuracy Class 0.5-25 to 15 to 30 to 70 C Temperature coefficient: ±0.2 % of full scale per 10 C Operating temperature Storage temperature Positive, negative and zero sequence alarms: Class 1 within 5 % voltage unbalance Class 1.0 for negative sequence current Fast over-current: 3 % of 350 %*In Analogue outputs: Class 1.0 according to total range Option EF4/EF5: Class 4.0 according to total range To IEC/EN 60688-25 to 70 C (-13 to 158 F) -25 to 60 C (-13 to 140 F) if Modbus TCP/IP (option N) is available in the controller (UL/cUL Listed: Max. surrounding air temperature: 55 C/131 F) -40 to 70 C (-40 to 158 F) Climate 97 % RH to IEC 60068-2-30 Operating altitude Measuring voltage Measuring current Current overload 0 to 4000 m above sea level Derating 2001 to 4000 m above sea level: Max. 480 V AC phase-phase 3W4 measuring voltage Max. 690 V AC phase-phase 3W3 measuring voltage 100 to 690 V AC ±20 % (UL/cUL Listed: 600 V AC phase-phase) Consumption: Max. 0.25 VA/phase -/1 or -/5 A AC (UL/cUL Listed: from CTs 1 to 5 A) Consumption: Max. 0.3 VA/phase 4 I n continuously 20 I n, 10 sec (max. 75 A) 80 I n, 1 sec (max. 300 A) Measuring frequency Aux. supply 30 to 70 Hz Terminals 1 and 2: 12/24 V DC nominal (8 to 36 V DC operational). Max. 11 W consumption Battery voltage measurement accuracy: ±0.8 V within 8 to 32 V DC, ±0.5 V within 8 to 32 V DC @ 20 C Terminals 98 and 99: 12/24 V DC nominal (8 to 36 V DC operational). Max. 5 W consumption 0 V DC for 10 ms when coming from at least 24 V DC (cranking dropout) The aux. supply inputs are to be protected by a 2 A slow blow fuse. (UL/cUL Listed: AWG 24) DEIF A/S Page 15 of 19

Technical information Binary inputs Analogue inputs Multi-inputs Relay outputs Open collector outputs Analogue outputs Galvanic separation Response times (delay set to min.) Optocoupler, bi-directional ON: 8 to 36 V DC Impedance: 4.7 kω OFF: <2 V DC -10 to +10 V DC: Not galvanically separated. Impedance: 100 kω (G3) 0(4) to 20 ma: Impedance 50 Ω. Not galvanically separated (M15.X) 0(4) to 20 ma: 0 to 20 ma, ±1 %. Not galvanically separated Binary: Max. resistance for ON detection: 100 Ω. Not galvanically separated Pt100/1000: -40 to 250 C, ±1 %. Not galvanically separated. To IEC/EN60751 RMI: 0 to 1700 Ω, ±2 %. Not galvanically separated V DC: 0 to 40 V DC, ±1 %. Not galvanically separated Electrical rating: 250 V AC/30 V DC, 5 A. (UL/cUL Listed: 250 V AC/24 V DC, 2 A resistive load) Thermal rating @ 50 C: 2 A: Continuously. 4 A: t on = 5 sec, t off = 15 sec (Unit status output: 1 A) Supply: 8 to 36 V DC, max. 10 ma (terminal 20, 21, 22 (com)) 0(4) to 20 ma and ±25 ma. Galvanically separated. Active output (internal supply). Load max. 500 Ω. (UL/cUL Listed: Max. 20 ma output) Update rate: Transducer output: 250 ms. Regulator output: 100 ms Between AC voltage and other I/Os: 3250 V, 50 Hz, 1 min Between AC current and other I/Os: 2200 V, 50 Hz, 1 min Between analogue outputs and other I/Os: 550 V, 50 Hz, 1 min Between binary input groups and other I/Os: 550 V, 50 Hz, 1 min Busbar: Over-/under-voltage: <50 ms Over-/under-frequency: <50 ms Voltage unbalance: <250 ms Inverter: Over-current: <250 ms Over-/under-voltage: <250 ms Over-/under-frequency: <350 ms Overload: <250 ms Digital inputs: <250 ms Emergency stop: <200 ms Multi-inputs: 800 ms Wire failure: <600 ms Mounting Tightening torque DIN rail mount or base mount with six M4 screws 1.5 Nm for the six M4 screws (countersunk screws are not to be used) Safety To EN 61010-1, installation category (over-voltage category) III, 600 V, pollution degree 2 To UL 508 and CSA 22.2 no. 14-05, over-voltage category III, 600 V, pollution degree 2 EMC/CE To EN 61000-6-2, EN 61000-6-4, IEC 60255-26 DEIF A/S Page 16 of 19

Technical information Vibration Shock (base mount) 3 to 13.2 Hz: 2 mm pp. 13.2 to 100 Hz: 0.7 g. To IEC 60068-2-6 & IACS UR E10 10 to 60 Hz: 0.15 mm pp. 60 to 150 Hz: 1 g. To IEC 60255-21-1 Response (class 2) 10 to 150 Hz: 2 g. To IEC 60255-21-1 Endurance (class 2) 10 g, 11 ms, half sine. To IEC 60255-21-2 Response (class 2) 30 g, 11 ms, half sine. To IEC 60255-21-2 Endurance (class 2) 50 g, 11 ms, half sine. To IEC 60068-2-27 Bump 20 g, 16 ms, half sine. To IEC 60255-21-2 (class 2) Material Plug connections Tightening torque Tightening torque Protection Approvals UL markings All plastic materials are self-extinguishing according to UL94 (V1) AC current: 0.2 to 4.0 mm 2 stranded wire. (UL/cUL Listed: AWG 18) AC voltage: 0.2 to 2.5 mm 2 stranded wire. (UL/cUL Listed: AWG 20) Relays: (UL/cUL Listed: AWG 22) Terminals 98-116: 0.2 to 1.5 mm 2 stranded wire. (UL/cUL Listed: AWG 24) Other: 0.2 to 2.5 mm 2 stranded wire. (UL/cUL Listed: AWG 24) 0.5 Nm (5-7 lb-in) Display: 9-pole Sub-D female 0.2 Nm Service port: USB A-B Unit: IP20. Display: IP40 (IP54 with gasket: Option L). (UL/cUL Listed: Type Complete Device, Open Type). To IEC/EN 60529 UL/cUL Listed to UL508 Applies to VDE-AR-N 4105 Wiring: Use 60/75 C copper conductors only Mounting: For use on a flat surface of type 1 enclosure Installation: To be installed in accordance with the NEC (US) or the CEC (Canada) AOP-2: Maximum ambient temperature: 60 C Wiring: Use 60/75 C copper conductors only Mounting: For use on a flat surface of type 3 (IP54) enclosure. Main disconnect must be provided by installer Installation: To be installed in accordance with the NEC (US) or the CEC (Canada) Tightening torque Weight DC/DC converter for AOP-2: Wire size: AWG 22-14 0.5 Nm (4.4 lb-in) Panel door mounting: 0.7 Nm Sub-D screw: 0.2 Nm Base unit: 1.6 kg (3.5 lbs) Option J1/J4/J6/J7: 0.2 kg (0.4 lbs) Option J2: 0.4 kg (0.9 lbs) Option J8: 0.3 kg (0.58 lbs) Display: 0.4 kg (0.9 lbs) DEIF A/S Page 17 of 19

115 (4.528) 165 (6.486) 144 (5.669) ASC Plant Management data sheet Technical information 5.1.2 Unit dimensions in mm (inches) 115 (4.528) 15 (0.59) 115 (4.528) 215(8.465) 230 (9.055) 119(4.689) Display or AOP 220 (8.661) 20.0 (0.787) DEIF A/S Page 18 of 19

Ordering information 6. Ordering information 6.1 Order specifications and disclaimer 6.1.1 Order specifications Variants Type Options specification Type Option Option Option Option Option Example: Type Options specification Type Option Option Option Option Option ASC PM Solar H2 M14.4 M13.6 M15.8 6.1.2 Disclaimer DEIF A/S reserves the right to change any of the contents of this document without prior notice. The English version of this document always contains the most recent and up-to-date information about the product. DEIF does not take responsibility for the accuracy of translations, and translations might not be updated at the same time as the English document. If there is a discrepancy, the English version prevails. DEIF A/S Page 19 of 19