Electrically Released Brakes

Similar documents
For Dynamic Stopping and Cycling Applications

EM Series Electrically Released Brakes

EM Series Electrically Released Brakes

Permanent Magnet Electrically Released Brakes

UM Series UniModule. Pre-assembled, C-face Clutches and Brakes. Original Design Sizes 210 & 215. GEN 2 Design Sizes 50, 100 & 180

Packaged Electromagnetic Clutches/Brakes

EM Series Electro Module

available today from Warner Electric

ATC / ATB Series AT Clutches and Brakes

Shaft Mounted Clutches & Brakes

ATC / ATB Series AT Clutches and Brakes

EC / EB Series Electro Clutches and Brakes

Electro-Module EM-50, EM-100, EM-180, EM-210, EM-215

Primary Clutch/Brake Pin Drive, Spline Drive PCB-825, PCB-1000, PCB-1225 Primary Clutch/Brake Coupling PCBC-825, PCBC-1000, PCBC-1225

Preassembled Clutch/Electrically Released Brake Module

Preassembled Clutch/Electrically Released Brake Module

Electro Clutches and Brakes Shaft Mounted Clutches and Brakes

MB-825 Flange Mounted

Installation Instructions

Primary Brake Spline Drive Armature PB-825, PB-1000, PB-1225, PB-1525

Electro-Brake 375, 475, 650, 825, 1000, 1225

EB Series Electro Brake

Electrically Released Spring-Set Brakes & Unibrake AC Motor Brakes

Preassembled Clutch/Brake Module

Base Mounted Clutch/Brake Combinations in a Rugged Housing

Gen 2 Clutch/Brake UniModule UM-50, UM-100, UM-180

PB-500 Pin Drive, PB-500 Spline Drive PB-650 Pin Drive

Gen 2 Clutch/Brake UniModule UM-50, UM-100, UM-180

SF-120, SF-170, SF-250, SF-400 Bearing Mounted, Flange Mounted, SFC-120, SFC-170, SFC-250, SFC-400 Bearing Mounted, Flange Mounted

Installation Instructions

Service & Installation Instructions. An Altra Industrial Motion Company P WE Vented. Enclosed Version Optional

Installation Instructions

Installation Instructions

MCS-203 Dancer Control

Clutch Coupling. PCC-500 Normal Duty HUB VIEW COLLECTOR RING VIEW. Customer Shall Maintain: Warner Electric ( )

MCS-203 Dancer Control

PC-500 Clutch, PCC-500 Clutch Coupling, PCBC-500 Clutch/Brake Coupling P-203-WE

EB Series Electro Brake

SFC-825, SFC-1000, SFC-1225, SFC-1525 Heavy Duty Clutch Coupling and SFC-1525 High Torque Heavy Duty Clutch Coupling

Stearns Super-Mod Totally-Enclosed Non-Ventilated (TENV) Modules Featuring

Advanced Technology Tension Clutches

Electro-Packs EP-170, 250, 400, 500, 825, 1000, 1525

Primary Brakes PB-120, PB-170, PB-250, PB-400

Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB Size 50, 100, 180

Magnetic Particle Brakes and Clutches

Gen 2 Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB

Electrically Released Brakes FB-375, 475, 650

Easy Access with Removable Cover Panel

Air Champ RPM DPC-15T DPC-13T DPC-11T DPC-11T DPC-9T DPC-9T DPC-9T DPC-9T DPC-9T DPC-9T DPC-9T DPC-9T DPC-9T DPC-9T DPC-9T DPC-9T DPC-9T DPC-9T

Electrically Released Brakes FB-375, 475, 650

Four armature sizes. Simple. Powerful. Controllable.

Introduction to Armature Actuated Brakes (AAB) Operating Principle. Engaged Condition (power off) Disengaged Condition (power on)

Fractional HP Clutches/Brakes. A-Track Linear Actuators

AC Motor Brakes. General Information. Features. Add-On Brakes. Spring Applied Power-Off Operation. Motor Brake Coil Current. Mounting.

180VC WITH B5 FLANGE / M ,6 0, / M l 5,0 0,7 192 / M ,0 0,9 223

Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB

Air Champ DPC-9T & DPC-11T Static Torque in Inch-Pounds. Air Pressure in PSI

Section 5 MagnaShear (Fully Electric) Motor Brakes

TB Series Brakes Tension Control System

Adjustable Torque Controls

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

ERD Series Electrically Released Brakes

DC MOTORS NEMA FRAME SCR RATED

Powerful + Efficient + Reliable

Crane Control Class 5010

CBC-300 & CBC Series Dual Channel Adjust Clutch/Brake Controls

Stearns Heavy Duty Clutches & Brakes... Rugged, Reliable

Blue Max 2000 Vector Duty 2000:1 Constant Torque Motors

Serving Industrial Markets Since 1961:

General Purpose Three Phase Motors TEFC (IP55) High Efficiency. Standard Features

CB Series Clutch / Brake

DC Motors. DC Motors. Gearmotors. AC / DC Controls. Accessories / Kits. Mods / Factory Options. X-Ref / Index. Tech. Information.

Magnetic particle clutches and brakes

Electrical Data Application Engineering

SFP-250 and SFP-400. Installation Instructions. An Altra Industrial Motion Company P-231-WE

Current Controlled Electric Hysteresis Brakes Advantages The superior design of these hysteresis devices provides several inherent advantages over mag

TCS Series Analog/Manual Controls

Standard Street, El Segundo CA BRUSHLESS SERVO MOTORS

Table of Contents. Introduction 1 Brake Selection 2

Combination Clutch/Brake Packages

NEW BRAKE DESIGN For C-FACE Motors from NEMA Frame Motors

PSI Series Features: Trouble-free design for long life. Simple mechanical actuation

MTB II Modular Tension Brakes

Combination Clutch/Brake

SPECIFICATION HOW TO ORDER NOMENCLATURE. Fractional Hp Clutches & Brakes SPECIFICATION HOW TO ORDER NOMENCLATURE PT2--24

Section 15 Unit Selection Procedures

Armature Actuated Brakes RoHS Compliant- meets the requirements of the Restriction of Hazardous Substances Directive


Basic Hydraulic Features. Basic Mechanical Features

Electromagnetic clutch-brake combinations INTORQ

Clutch/Brakes for Lawn & Garden Equipment

Electromagnetic Particle Brakes Model: PRB-H

IEC Metric Motors DC Metric Motors Metric (IEC) Frame - SCR Rated - IP54

ROBATIC ROBA -quick ROBA -takt. Reliable coupling and braking.

BALDOR MN413 Brakes Manual

Tension Control Systems for Light, Medium, and Heavy-Duty Tensioning

Inverter Speed Ratio Information

Now you can get design flexibility and lasting performance from our complete family of AccuDrive Precision Products.

EXPERTS IN MOTION CONTROL I N D U S T R I A L P R O D U C T S

Wrap Spring Clutches and Clutch/Brakes

Transcription:

ER Series Electrically Released Brakes Specifications Inertia lb.ft. Weight lbs. Total Model Bore Size Voltage DC Static Torque lb. ft. Max. RPM Drive Arm. & Carrier Hub Arm. & Carrier Hub Weight lbs. ER-375.500" &.65" 90V 0.5 5000.00.00.60.49 4.5 ER-475.500" to.000" Dodge #008 90V 4500.07.006.3 6.3 ER-650.500" to.375" Dodge #30 90V 56 3600.06.00.3.6 3. ER-85.500" to.65" Pin.33.043 4.783.857 ND Dodge #65 90V 5 3600 Spline.36.006 5.63.834 5.6 ER-85.500" to.500" Pin.33.043 4.783.857 HD Browning #H- 90V 5 3600 Spline.36.006 5.63.834 5.6 ER-5.937" to 3.00" Pin.667.380 0.7 6.76 35-75V 400 3000 ND Dodge #3030 Spline.737.077 3.37 3.58 60.3 ER-5.75" to.687" Pin.667.380 0.7 6.76 HD Browning #Q- 35-75V 400 3000 Spline.737.077 3.37 3.58 60.3 Bushing Part Numbers Bushing Number Shaft Keyway Warner Size Size Electric Browning / /8 x /6 80-000 9/6 /8 x /6 80-0003 5/8 3/6 x 3/3 80-0004 /6 3/6 x 3/3 80-0005 3/4 3/6 x 3/3 80-0006 3/6 3/6 x 3/3 80-0007 7/8 3/6 x 3/3 80-0008 5/6 /4 x /8 80-0009 H- /4 x /8 80-000 -/6 /4 x /8 80-00 -/8 /4 x /8 80-00 -3/6 /4 x /8 80-003 -/4 /4 x /8 80-004 -5/6 5/6 x 5/3 80-005 -3/8 5/6 x 5/3 80-006 -7/6 3/8 x 3/6 80-007 H- -/ 3/8 x 3/6 80-008 3/4 3/6 x 3/3 80-006 3/6 3/6 x 3/3 80-007 7/8 3/6 x 3/3 80-008 5/6 /4 x /8 80-009 /4 x /8 80-0030 -/6 /4 x /8 80-003 -/8 /4 x /8 80-003 -3/6 /4 x /8 80-0033 -/4 /4 x /8 80-0034 -5/6 5/6 x 5/3 80-0035 QI- -3/8 5/6 x 5/3 80-0036 -7/6 3/8 x 3/6 80-0037 -/ 3/8 x 3/6 80-0038 -9/6 3/8 x 3/6 80-0039 -5/8 3/8 x 3/6 80-0040 -/6 3/8 x 3/6 80-004 -3/4 3/8 x 3/6 80-004 -3/6 / x /4 80-0043 -7/8 / x /4 80-0044 -5/6 / x /4 80-0045 / x /4 80-0046 -/6 / x /4 80-0047 -/8 / x /4 80-0048 QI- -3/6 / x /4 80-0049 -/4 / x /4 80-0050 Browning is registered to Emerson Electric Co. Dodge and Browning bushings are also available in metric bores. Bushing Number Shaft Keyway Warner Size Size Electric Browning -5/6 5/8 x 5/6 80-005 -3/8 5/8 x 5/6 80-005 -7/6 5/8 x 5/6 80-0053 -/ 5/8 x 5/6 80-0054 QI- -9/6 5/8 x 5/6 80-0055 -5/8 5/8 x 5/6 80-0056 -/6 5/8 x 5/6 80-0057 / /8 x /6 80-03 9/6 /8 x /6 80-03 5/8 3/6 x 3/3 80-033 /6 3/6 x 3/3 80-034 3/4 3/6 x 3/3 80-035 3/6 3/6 x 3/3 80-036 7/8 3/6 x 3/3 80-037 5/6 /4 x /8 80-038 /4 x /8 80-039 -/6 /4 x /8 80-040 65 -/8 /4 x /8 80-04 -3/6 /4 x /8 80-04 -/4 /4 x /8 80-043 -5/6 5/6 x 5/3 80-044 -3/8 5/6 x 5/3 80-045 -7/6 3/8 x 3/6 80-046 -/ 3/8 x 3/6 80-047 -9/6 3/8 x 3/6 80-048 -5/8 3/8 x 3/6 80-049 5/6 /4 x /8 80-06 /4 x /8 80-063 -/6 /4 x /8 80-064 -/8 /4 x /8 80-065 -3/6 /4 x /8 80-066 -/4 /4 x /8 80-067 -5/6 5/6 x 5/3 80-068 -3/8 5/6 x 5/3 80-069 3030-7/6 3/8 x 3/6 80-070 -/ 3/8 x 3/6 80-07 -9/6 3/8 x 3/6 80-07 -5/8 3/8 x 3/6 80-073 -/6 3/8 x 3/6 80-074 -3/4 3/8 x 3/6 80-075 -3/6 / x /4 80-076 -7/8 / x /4 80-077 Bushing Number Shaft Keyway Warner Size Size Electric Browning -5/6 / x /4 80-078 / x /4 80-079 -/6 / x /4 80-080 -/8 / x /4 80-08 -3/6 / x /4 80-08 -/4 / x /4 80-083 -5/6 5/8 x 5/6 80-084 -3/8 5/8 x 5/6 80-085 -7/6 5/8 x 5/6 80-086 3030 -/ 5/8 x 5/6 80-087 -9/6 5/8 x 5/6 80-088 -5/8 5/8 x 5/6 80-089 -/6 5/8 x 5/6 80-090 -3/4 5/8 x 5/6 80-09 -3/6 3/4 x 3/8 80-09 -7/8 3/4 x 3/8 80-093 -5/6 3/4 x 3/8 80-094 3 3/4 x 3/8 80-095 / /8 x /6 80-040 9/6 /8 x /6 80-04 5/8 3/6 x 3/3 80-04 /6 3/6 x 3/3 80-043 3/4 3/6 x 3/3 80-044 008 3/6 3/6 x 3/3 80-045 7/8 3/6 x 3/3 80-046 5/6 /4 x /6 80-047 /4 x /6 80-048 / /8 x /6 80-04 9/6 /8 x /6 80-04 5/8 3/6 x 3/3 80-043 /6 3/6 x 3/3 80-044 3/4 3/6 x 3/3 80-045 3/6 3/6 x 3/3 80-046 7/8 3/6 x 3/3 80-047 5/6 /4 x /6 80-048 30 /4 x /8 80-049 -/6 /4 x /8 80-0430 -/8 /4 x /8 80-043 -3/6 /4 x /8 80-043 -/4 /4 x /8 80-0433 -5/6 5/6 x 5/3 80-0434 -3/8 5/6 x 5/3 80-0435 Warner Electric 800-34-3369

Electrically Released Brakes ER-375, ER-475, ER-650 ER Series C L M* N** Removable plug in ends for /" conduit P Mounting holes are within 0.00 of true position relative to pilot diameter. H J* K Q X dia. (Y) holes equally spaced on Z dia. A AB AC For Bore & Keyway sizes see chart below R AA Pilot S T D G** U dia. (V) holes equally spaced on W dia. B E F * Inside Mounting ** Outside Mounting Mounting Requirements Customer Shall Maintain:. Squareness of brake mounting face with armature hub shaft within.006 T.I.R.. Concentricity of brake mounting pilot diameter with armature hub shaft within.00 T.I.R. 3. If magnet mounting surface is a magnetic material, the magnet is to be insulated approximately /" from that surface with a plate or spacers of non-magnetic material. ER-375 available outside mounted only. Bore and Keyway Dimensions Size Bore Dia. Keyway 375.50/.500 /8 x /6.66/.65 3/6 x 3/3.500 -.56 /8 x /6 475.65 -.875 3/6 x 3/3.937 -.000 /4 x /8.500 -.56 /8 x /6 650.65 -.875 3/6 x 3/3.000 -.50 /4 x /8.3 -.375 5/6 x 5/3 All dimensions are nominal, unless otherwise noted. Size A Max. B Max. C Max. D E F Max. G H Max. J K L M N P 375 4.078.583.583.03.40.600 5/6-8 UNC-3A 3.35.547 3.750 475 5.7 3.95 3.74.03.630.43 3/8-6 UNC-3A.390 8-3 3.875.547.354.36 3.750 650 6.578 3.55 3.55.03.880.54 5/6-8 5/6-8 UNC-3A.54 UNC-3A 4.800.547 3.750 Size Q Max. R S T Sq. U V W Dia. X Y Z Dia. AA Dia. AB AC 5.65.350 375 4.505 3 5.000 3/3-3/4 5.63.34 6.500.49.08.065-3/6 I.M. 475 5.000 45 5.000 4 5.875 8.375 9/3 6.498.403.0.06 -/6 O.M. 8.000.358.358.8 650 5.844 45 6.500 4 7.50 4 3.688 -/3-3/8 7.998.338.338.80 Warner Electric 800-34-3369

ER Series Electrically Released Brakes ER-85, ER-5 ER-85 and ER-5 Normal Duty (N.D.) ER-85 and ER-5 Heavy Duty (H.D.) K J K J Removable plug in ends for /" conduit Q I G I G Pilot Dia. V R A B M D E N P O H A B C L D E N P O H S dia. (T) holes equally spaced on U dia. Mounting holes are within 0.005 of true position relative to pilot diameter ER-85 & ER-5 Magnet View (Same for Pin Drive and Spline Drive) Mounting Requirements Customer Shall Maintain:. Squareness of magnet mounting face with armature shaft within.006 T.I.R.. Concentricity of magnet mounting pilot diameter with armature shaft within.00 T.I.R. 3. If magnet mounting surface is a magnetic material, the magnet is to be insulated approximately /" from that surface with a plate or spacers of non-magnetic material. A B C D E G H I J K L Size Max. Dia. Max. Min. Min. 85 N.D. 8.656 4.65.593.500 5.65.53 85 H.D. 8.656.500.56.50.765 5.65.53 5 N.D..67 6.875 3.000 3.000 7.67.546 5 H.D..67 4.093.34.500.7 7.67.546 M N O P Q R S T U V Size When New Max. Max. 85 N.D..093.56 85 H.D..53 5 N.D..56.593 5 H.D..56.080 6.750 4.359 3.750.338 3.50.080 6.750.338 3.546 3.750 3.50.500 8.796 6.8 3.750.338 6.376.500 8.796 5.03 3.750.338 6.376 5/6-8.687.546 UNC-3A 5/6-8.687.546.06 UNC-3A 5/6-8.78.546 UNC-3A 5/6-8.78.546.06 UNC-3A.358 6 4.50 3.503.358 6 4.50 3.503.358 6 7.50 6.378.358 6 7.50 6.378 Bore and Keyway Dimensions ER-85 Bore Dia. Keyway Pin.500 -.56 /8 x /6 Drive.65 -.875 3/6 x 3/3.937 -.50 /4 x /8.3 -.375 5/6 x 5/3.437 -.500 3/8 x 3/6.56 -.65* 3/8 x 3/6 Spline.500 -.56 /8 x /6 Drive.375 -.65 3/6 x 3/3.937 -.87 /4 x /8.50* /4 x /8.3-.375* 5/6 x 5/3.437 -.500* 3/8 x 3/6 ER-5 Pin.937 -.50 /4 x /8 Drive.3 -.375 5/6 x 5/3.437 -.750 3/8 x 3/6.8-.50 / x /4.3 -.750 5/8 x 5/6.87-3.000* 3/4 x 3/8 Spline.750 -.875 3/6 x 3/3 Drive.937-.50 /4 x /8.3 -.375 5/6 x 5/3.437 -.750 3/8 x 3/6.8 -.06 / x /4.5 -.50* / x /4.3 -.687 5/8 x 5/6 *Key furnished Warner Electric 800-34-3369 3

Electrically Released Brakes For Dynamic Stopping and Cycling Applications Warner Electric s modular design brakes and clutch/brake units offer material handling system users a high performance alternative to spring-set brakes. These modular units provide long life, maintenance free operation, and consistent performance with minimal downtime. Permanent Magnet Modules Brake Modules (FBB) For mounting between a C-face motor and a gearbox or reducer These brakes are offered in power-off types for double shaft motors and for installation between C-face motor and reducer or other drive device. Powerful permanent magnets generate braking torque. The brakes release when voltage is applied to the coil, countering the force of the permanent magnets. No power is required to stop or hold a load. An optional integral conduit box provides simple wiring direct from the motor power leads. Designed for dynamic stopping operations Brake automatically engages when power is turned off High cycle rate capability Never needs adjustment automatically compensates for wear Powerful permanent magnets provide braking force Choice of open or enclosed brakes Prepackaged, preburnished UM version EM Series Shaft mounted, vented housing Use for brake alone applications. EUM Series Shaft mounted, totally enclosed non-vented housing Three C-face Compatible Designs The UM Series (UniModule Clutch/Brakes) are preassembled clutch/electrically released brake modules. The UM-00-FBC brake/motor clutch combination is used for clutch/power-off brake applications. It mounts directly to C-face compatible components. The UM-030-FBC brake/input clutch combination is used for clutch/power-off brake applications. It has shafts on both the input and output sides for base mounting. The EUM Series (Enclosed Motor Brakes) are totally enclosed non-vented units that keep wear particles in and contaminants out. Features Single armature for brake alone applications Output shaft Permanent magnets UL listed and CSA certified EM-FBB Available in 4 sizes EUM-FBB Available in 4 sizes The EUM-FBB brake unit can be mounted between two C-face compatible components. The EUM-MBFB motor brake is mounted directly to the rear of a double-shafted motor. The EM Series (Electro Module Brakes and Clutch/Brakes) are comprised of individual units that may bolt together to form various combinations: The EM-FBB brake module mounts between a C-face motor and a gear box or reducer. The EM-MBFB motor brake module is mounted to the rear of a double-shafted motor. The EM-FBC brake module is used in combination with a motor clutch or input clutch unit to make a cluch/electrically released brake or can be used alone as a brake only. EM-FBB Electro Module brake unit between a motor and a reducer. 4 Warner Electric 800-34-3369

Permanent Magnet Modules Motor Brake Modules (MBFB) For mounting directly to the rear of a double-shafted motor Electrically Released Brakes C-face Compatible Brakes and Clutch/Brakes Clutch/Brake Modules (FBC) Clutch/Fail-safe brake for mounting between a C-face motor and a gearbox or reducer EM Series vented housing Use as a motor brake on C-face type motors. EUM Series totally enclosed non-vented housing EM Series Modular unit with C/B capability UM Series Fully assembled C/B combination package Combine with a motor or input clutch for clutch/brake applications or use alone as a brake only. Features Single armature design Complete torque control Precision cast housing Ceramic type permanent magnets EM-MBFB Available in 4 sizes EUM-MBFB Available in 5 sizes Features Dual armature for clutch/brake combination Output shaft Can be base mounted for use as a separate drive unit. EM-FBC Available in 3 sizes UM-FBC Available in 4 size combinations Typical mounting of an MBFB module on the back of a C-face motor EM-FBC Electro Module brake unit combined with a motor clutch module UM-FBC UniModule clutch/brake mounted on a base Warner Electric 800-34-3369 5

Electrically Released Brakes UniModule Clutch/Electrically Released Brake Combination UM-FBC Series Fan cooled for long life and consistent performance. Completely sealed coils NEMA C-face compatible design Easy set screw access Single conduit entrance Bearing mounted rotor. Heavy duty bearings maintain tight concentricity and running efficiency. Autogaps automatically adjust for wear. High torque, long life, asbestos-free friction material Finned design for maximum heat dissipation. Warner Electric offers the convenience of pre-assembled UniModule clutch/electrically released brake packages. Assembly, alignment, and pre-burnishing have been done at the factory. Bolt it on, wire it up, and your clutch/electrically released brake is ready to go. Available in both C-face and base mounted versions. Warner Electric s unique design employs powerful permanent magnets for maximum torque when power is removed from the brake coil. A small amount of electrical power applied to the brake coil nullifies the permanent magnets and the brake releases. No springs to limit cycle rates. Never any adjustments. No lubrication. These brakes are recommended for dynamic cycling operations only. 6 Warner Electric 800-34-3369

UM-FBC Series Electrically Released Brakes Selection UniModule clutch/electrically released brake units may be mounted directly to NEMA C-face motors and reducers, or can be base mounted.. Select Configuration a. NEMA C-face Mounting (00 Configuration) Verify the unit will be cycled frequently. To select the correct UniModule package, determine the NEMA frame size of your motor and/or reducer, and choose the corresponding size UniModule from the Frame Size Selection chart. Verify torque ratings. b. Base Mounting (030 Configuration) Verify the unit will be cycled frequently. Select the correct size module from the Horsepower vs. Shaft Speed chartby determining the motor horsepower and RPM at the module location. The correct size UniModule is shown at the intersection of the HP and operating speed. For additional sizing information, refer to the technical sizing procedure (step ). Horsepower vs. Shaft Speed HP /4 / 3/4 -/ 3 5 7-/. Determine Technical Requirements Technical considerations for sizing and selection are torque and heat dissipation. Each merits careful consideration, especially heat dissipation as over time, use in excessive temperature environments will have an adverse effect on bearing life and coil wire insulation integrity. Compare the calculated torque requirement with the average dynamic torque ratings. Select a unit with adequate torque. If the unit selected on torque is different than the unit selected based on heat, select the larger size unit. SHAFT SPEED AT CLUTCH (IN RPM) 00 00 300 400 500 600 700 800 900 000 00 00 500 800 000 400 3000 3600 UM-50 UM-00 or UM-80 UM-0 or UM-5 Frame Size Selection and Technical Ratings Chart Static Torque Static Torque NEMA UniModule Brake Clutch Max. Voltage Frame Size Size lb.ft. lb. RPM DC 56C/48Y 8C/43TC 84C/45TC 3C/8TC 5C/84TC UM-50* 0.5 6 UM-00** 30 3600 4 or 90 UM-80 30 3600 4 or 90 UM-0 56 95 3600 4 or 90 3TC/5TC UM-5 56 95 3600 4 or 90 *For 56C/48Y C-frame motors 3/4 HP and smaller, the UM-00 size may be used where extended life is desirable. **The UM-00 size is recommended for motors HP and larger. Warner Electric 800-34-3369 7

Electrically Released Brakes UM-FBC Series a. Heat Dissipation Sizing Friction surfaces slip during the initial period of engagement and, as a result, heat is generated. The clutch/brake selected must have a heat dissipation rating greater than the heat generated by the application. Therefore, in high inertia or high cycle rate applications, it is necessary to check the heat dissipation carefully. Inertia, speed and cycle rate are the required parameters. Heat dissipation requirement is calculated as follows: E =.7 x WR x (N/00) x F where: Heat Dissipation Curves Size 50 Heat Dissipation (ft. lbs./min.) Maximum Speed 3600 RPM 000 0000 8000 50 F 6000 4000 00 F 000 0 0 900 800 700 3600 Speed (RPM) E = Heat (lb. ft./min.) WR = Total reflected inertia at the clutch/brake shaft. Include the clutch/brake output inertia. (lb.ft. ) N = Speed in revolutions per minute. (RPM) F = Cycle rate in cycles per minute (CPM) Compare the calculated heat generated in the application to the unit ratings using the heat dissipation curves. Select the appropriate unit that has adequate heat dissipation ability. Heat Dissipation (ft. lbs./min.) Size 00/80 8000 5000 000 9000 6000 3000 0 Maximum Speed 3600 RPM 50 F 00 F 0 900 800 700 3600 Speed (RPM) Heat Dissipation (ft. lbs./min.) Size 0/5 36000 30000 4000 8000 000 6000 0 Maximum Speed 3600 RPM 50 F 00 F 0 900 800 700 3600 Speed (RPM) 8 Warner Electric 800-34-3369

UM-FBC Series Electrically Released Brakes b. Torque Sizing For most applications, the correct size clutch/brake can be selected from the Horsepower vs. Shaft Speed chart on page 7. Determine the motor horsepower and the RPM at the clutch/brake. The correct size unit is shown at the intersection of horsepower and shaft speed. If the static torque requirements are known, refer to the technical ratings chart to select a unit. For some applications, the torque requirement is determined by the time allowed to accelerate and decelerate the load. (This time is generally specified in milliseconds.) For these applications, it is necessary to determine the torque requirement based on load inertia and the time allowed for engagement. The torque requirements are calculated as follows: T = (WR x N) / (308 x t) where: T = Average Dynamic Torque (lb. ft.) WR = Total reflected inertia at the clutch/brake shaft. Include the clutch/brake output inertia. (lb. ft. ) N = Speed in revolutions per minute. (RPM) t = Time allowed for the engagement (sec) C-face Electrically Released Brake Dynamic Torque Curves Dynamic Torque (lb.ft.) Dynamic Torque (lb.ft.) Dynamic Torque (lb.ft.) Size 50 6 4 0 8 6 4 Size 00/80 3 8 4 0 6 8 4 0 0 Size 0/5 96 Maximum Speed 3600 RPM Static Torque 0.5 lb.ft. 50% Current 0 0 900 800 700 3600 84 7 60 48 36 4 0 0 00% Current Speed Difference in RPM Maximum Speed 3600 RPM Static Torque lb.ft. 50% Current 900 800 700 3600 Speed Difference in RPM Maximum Speed 3600 RPM Static Torque 56 lb.ft. 50% Current 00% Current 00% Current 900 800 700 3600 Speed Difference in RPM C-face Clutch Dynamic Torque Curves Dynamic Torque (lb.ft.) Dynamic Torque (lb.ft.) Dynamic Torque (lb.ft.) Size 50 6 4 0 8 6 4 Maximum Speed 3600 RPM Static Torque 0.5 lb.ft. 00% Current 50% Current 0 0 900 800 700 3600 Speed Difference in RPM Size 00/80 Maximum Speed 3600 RPM 3 8 4 0 6 8 4 0 0 96 84 7 60 48 36 4 0 0 Static Torque lb.ft. 00% Current 50% Current 900 800 700 3600 Speed Difference in RPM Size 0/5 Maximum Speed 3600 RPM Static Torque 95 lb.ft. Speed Difference in RPM 00% Current 50% Current 900 800 700 3600 Warner Electric 800-34-3369 9

Electrically Released Brakes UM-FBC Series Specifications (Max. Speed 3600 RPM) Component Inertia WR (lb. ft. ) 00 030 Nominal Weight (lbs.) Armature Rotor w/fan Output Input Rotor w/fan NEMA Size Voltage DC 00 030 (both) Hub Shaft and Hub Shaft Shaft and Hub Frame Size 50 00 80 0 5 4 90 4 90 5.08.00.00.00.00.00.00 56C/48Y 6 9.046.00.00.046.00.00.046 56C/48Y 4 8C/43TC 90 6 9.046.00.00.046.00.00.046 84C/45TC 4 3C/8TC 36 47.6.06.04.90.06.05.83 90 5C/84TC 4 90 37 48.6.06.06.90.07.06.83 3TC/5TC 3. Select Options Warner Electric Enclosed UniModules can be fitted with several accessories to extend their capacity and ease of mounting. 4. Select Control All electrically released modules require a control with a potentiometer that will vary brake channel output. UM-FBC units require either a CBC-300 or a CBC 500/550 control. UM Combination UM Model No. Voltage DC Part No. UM-50-00FBC 4 5370-73-037 UM-50-00FBC 90 5370-73-036 UM-00-00FBC 4 5370-73-53 UM-00-00FBC 90 5370-73-5 Motor Clutch/ UM-80-00FBC 4 5370-73-047 ER Brake UM-80-00FBC 90 5370-73-046 UM-0-00FBC 4 537-73-03 UM-0-00FBC 90 537-73-0 UM-5-00FBC 4 537-73-099 UM-5-00FBC 90 537-73-079 UM-50-030FBC 4 5370-73-04 UM-50-030FBC 90 5370-73-04 UM-00-030FBC 4 5370-73-54 Input Clutch/ UM-00-030FBC 90 5370-73-55 ER Brake UM-80-030FBC 4 5370-73-05 UM-80-030FBC 90 5370-73-05 UM-0-030FBC 4 537-73-08 UM-0-030FBC 90 537-73-07 UM-5-030FBC 4 537-73-00 UM-5-030FBC 90 537-73-0 Accessories Description UM Size Part No. Conduit Box Base Mount Kit for 030 FBC Motor Mount Kit for 00 FBC UM series All sizes 5370-0-04 50/00 5370-0-036 80 5370-0-037 0/5 537-0-039 50/00 5370-0-00 80 5370-0-0 0/5 537-0-0 How to Order. Specify model number and voltage or the corresponding part number.. Specify conduit box, if desired. See the Controls Section. 3. Specify required control unit. See the Controls Section. Ordering Example UM-50-00FBC, 90V or 5370-73-036; 5370-0-04 conduit box; CBC-300 control. 0 Warner Electric 800-34-3369

UM-FBC Series Electrically Released Brakes UM-00 FBC Motor Clutch/Electrically Released Brake F Optional Conduit Box V A /" Conduit Hole Both Ends /" Conduit Hole Both Ends H G K M J C N D E L 0 Motor Clutch 0 Brake B Note: Conduit box is optional and is ordered separately. All dimensions are nominal, unless otherwise noted. Size A B C D E F G H J K L M N (Key) 50 7.8 5.375.83 6.750.65.938 6.688 3.50.88 75 5.53 4.438 3/6 x 3/6 x -/4 00 7.8 5.375.83 6.750.65.938 6.688 3.50.88 75 5.53 4.438 3/6 x 3/6 x -/4 80 7.359 5.375.89 6.750.875.938 6.688 3.50.88 75 5.53 4.438 3/6 x 3/6 x -/4 0 9.688 7.03.500 9.50.5.65 9.688 3.50.88 70 6.869 5.766 /4 x /4 x 5 0.568 7.44 3.5 9.5.375. 9.688 3.50.88 70 6.869 5.766 5/6 x 5/6 x Motor Mount (M) F (4) slots E B For use with 00, 040, 0, 0 FBB and 00 FBC Combinations. A D C Size A B C D E F Part No. 50/00 9.5 8.5.00 8.000 3.50.797 x.406 5370-0-00 80 9.5 8.5.00 8.000 4.50.797 x.406 5370-0-0 0/5.50 0.50.00 9.000 5.5.750 x.406 537-0-0 Warner Electric 800-34-3369

Electrically Released Brakes UM-030 FBC Input Clutch/Electrically Released Brake UM-030 FBC-Input Clutch/Electrically Released Brake Base Mounted UM-FBC Series V B A P R T U I Optional Conduit Box /" Conduit Hole Both Ends /" Conduit Hole Both Ends Q C C D S K 30 Input Clutch 0 Brake L J H F G E F H N O M N Note: Mounting base and conduit box are optional and are ordered separately. All dimensions are nominal, unless otherwise noted. Size A B C Min. D E F G H I J K 50 6.50 0.047.83.65 6.9.09 4.000.344 6.688 3.500 6.844 80 6.50 0.88.89.875 6.9.09 4.000.344 6.688 4.500 7.844 0 8.56 3.766.500.5 8.938.469 6.000.438 9.688 5.50 9.906 Size L M N O P Q R S T U V 50.000 6.000.500 5.000 3.50.88 75 5.53 4.438.5.03 80 3.000 6.65.83 5.000 3.50.88 75 5.53 4.438.5.03 0 3.375 9.000.65 7.750 3.50.88 70 6.859 5.766.65.03 Base (B) E (4) Slots For use with 030 FBC units. Size A B C D E F G Part No. 50/00 6.000 5.000 6.9 4.000.750 X.406 3.500.000 5370-0-036 80 6.65 5.000 6.9 4.000.750 X.406 4.500 3.000 5370-0-037 0 9.000 7.750 8.938 6.000.750 X.53 5.50 3.375 537-0-09 F G A D C B Warner Electric 800-34-3369

Enclosed UniModules Electrically Released Brakes Preassembled, Totally Enclosed, Electrically Released Brake Units Rugged, cast housing provides strength Totally enclosed Never needs adjustment Permanent magnets provide holding torque NEMA C-face compatible design FBB Brake Module MBFB Motor Brake Module Available in Two Design Styles EUM-FBB Brake Module Use for brake alone applications. Mounts between a motor and gear box or reducer. Available in four sizes. EUM-MBFB Motor Brake Module Mounts to a double shafted C-face motor. Available in five sizes. Warner Electric offers the convenience of pre-assembly in UniModule electrically released brake packages. Assembly, alignment, and preburnishing have been done at the factory. Bolt it on, wire it up, and your electrically released brake is ready to go. (Control and conduit box optional) Care must be exercised to assure proper sizing and selection of electrically released brakes. Motor brakes are used for dynamic stopping and holding of loads when power is removed from the motor. Typical applications include conveyors, process equipment, and lifting devices. Warner Electric brakes are designed for NEMA C-face motors which match the motor frame size and shaft diameter to the brake. To select a brake, determine the motor frame size and pick an MBFB for double shafted motors or an FBB for mounting between a motor and a gear reducer. Select the torque required for the application. Higher torque brakes stop loads faster. Lower torque models provide softer stopping to prevent boxes on conveyors from tipping or skidding. They are sized to provide nominal stopping of a motor in the event of power loss. If your application requires true Fail safe braking, the brake must be sized to meet or exceed peak motor torque and placed as close to the load shaft as possible. Peak motor torque can be determined by the formula: (HP x 550) Peak Torque = Motor Speed Warner Electric 800-34-3369 3

Electrically Released Brakes EUM-FBB, EUM-MBFB Selection Enclosed UniModules Warner Electric Electrically Released Enclosed UniModules are available in two styles. The EUM-FBB Brake Module is used in brake only applications and mounts between a C-face motor and a gear box or reducer. The EUM-MBFB Motor Brake Module mounts to the back of a double shafted motor. Note: Care must be exercised when selecting a brake to ensure it is sized properly for your application.. Select Configuration a. FBB for NEMA C-face Mounting Between a Motor and Reducer b. MBFB for NEMA C-face Mounting on the Back of a Double Shafted Motor Verify that the brake will be cycled frequently. Determine the NEMA C-face frame size of your motor and/or reducer, and choose the corresponding size Enclosed UniModule MBFB from the Frame Size Selection chart, and verify that the motor shaft diameter and mounting bolt circle are the same for the brake and the motor. Size EUM-00 modules utilize a 5/8" diameter shaft to fit 56C/48Y motor frames with components of EUM-80 units for higher torque and heat dissipation capacity than the EUM-50. EUM-MBFB Frame Size Selection. Determine Technical Requirements Technical considerations for sizing and selection are torque and heat dissipation. Each merits careful consideration, especially heat dissipation as over time, use in excessive temperature environments will have an adverse effect on bearing life and coil wire insulation integrity. Compare the calculated torque requirement with the average dynamic torque ratings. Select a unit with adequate torque. If the unit selected on torque is different than the unit selected based on heat, select the larger size unit. Verify that the brake will be cycled frequently. Determine the NEMA C-face frame size of your motor and/or reducer, and choose the corresponding size Enclosed UniModule from the Frame Size Selection chart. Size EUM-00 modules utilize a 5/8" diameter shaft to fit 56C/48Y motor frames with components of EUM-80 units for higher torque and heat dissipation capacity than the EUM-50. EUM-FBB Frame Size Selection NEMA Frame Size 56C/48Y 8C/43TC 84C/45TC 3C/8TC 5C/84TC EUM Size EUM-50* EUM-00** EUM-80 EUM-0 3TC/5TC EUM-5 *For 56C/48Y C-frame motors 3/4 HP and smaller, the EUM-00 size may be used where extended life is desirable. **The EUM-00 size is recommended for motors HP and larger. NEMA EUM Bolt Hole Motor Shaft Frame Size Brake Size Mounting Circle Dia. 56C/48Y EUM-50* 5.875 0.65 EUM-00** 8C/43TC 84C/45TC EUM-80 5.875 0.875 3C/8TC EUM-0-7/8 7.5 0.875 5C/84TC EUM-0 7.5.5 *For 56C/48Y C-frame motors 3/4 HP and smaller, the EUM-00 size may be used where extended life is desirable. **The EUM-00 size is recommended for motors HP and larger. Horsepower vs. Shaft Speed HP /4 / 3/4 -/ 3 5 7-/ 0 SHAFT SPEED AT CLUTCH (IN RPM) 00 00 300 400 500 600 700 800 900 000 00 00 500 800 000 400 3000 3600 EUM-0/5 EUM-00/80 EUM-50 4 Warner Electric 800-34-3369

Enclosed UniModules Electrically Released Brakes a. Heat Dissipation Sizing Friction surfaces slip during the initial period of engagement and, as a result, heat is generated. The clutch/brake selected must have a heat dissipation rating greater than the heat generated by the application. Therefore, in high inertia or high cycle rate applications, it is necessary to check the heat dissipation carefully. Inertia, speed and cycle rate are the required parameters. Heat Dissipation Curves EUM 50 Heat dissipation requirement is calculated as follows: E =.7 x WR x (N/00) x F where: E = Heat (lb. ft./min.) WR = Total reflected inertia at the clutch/brake shaft. Include the clutch/brake output inertia. (lb.ft. ) N = Speed in revolutions per minute. (RPM) F = Cycle rate in cycles per minute (CPM) EUM 00/80 Compare the calculated heat generated in the application to the unit ratings using the heat dissipation curves. Select the appropriate unit that has adequate heat dissipation ability. EUM 0/5 (fan not available for 5) Heat Dissipation (lb.ft./min.) 0000 8000 Fan Cooled 6000 4000 Standard 000 0 900 800 700 3600 Speed (RPM) Heat Dissipation (lb.ft./min.) 0000 8000 6000 4000 000 Standard Fan Cooled 0 900 800 700 3600 Speed (RPM) Heat Dissipation (lb.ft./min.) 0000 6000 000 8000 4000 Fan Cooled Standard 0 900 800 700 3600 Speed (RPM) b. Torque Sizing For most applications, the correct size clutch/brake can be selected from the Horsepower vs. Shaft Speed chart. Determine the motor horsepower and the RPM at the clutch/brake. The correct size unit is shown at the intersection of horsepower and shaft speed. If the static torque requirements are known, refer to the technical ratings chart to select a unit. For some applications, the torque requirement is determined by the time allowed to accelerate and decelerate the load. (This time is generally specified in milliseconds.) For these applications, it is necessary to determine the torque requirement based on load inertia and the time allowed for engagement. The torque requirements are calculated as follows: T = (WR x N) / (308 x t) where: T = Average Dynamic Torque (lb. ft.) WR = Total reflected inertia at the clutch/brake shaft. Include the clutch/brake output inertia. (lb. ft. ) N = Speed in revolutions per minute. (RPM) t = Time allowed for the engagement (sec) C-face Electrically Released Brakes Dynamic Torque Curves Dynamic Torque (lb.ft.) Size 50 6 4 0 8 6 4 Maximum Speed 3600 RPM Static Torque 0.5 lb.ft. 00% Current 50% Current 0 0 900 800 700 3600 Speed Difference in RPM Dynamic Torque (lb.ft.) Size 00/80 Maximum Speed 3600 RPM Static Torque lb.ft. 3 8 4 0 6 8 4 0 0 00% Current 50% Current 900 800 700 3600 Speed Difference in RPM Dynamic Torque (lb.ft.) Size 0/5 Maximum Speed 3600 RPM Static Torque 56 lb.ft. 96 84 7 60 48 36 4 0 50% Current 00% Current 0 900 800 700 3600 Speed Difference in RPM Warner Electric 800-34-3369 5

Electrically Released Brakes Preassembled, Totally Enclosed, Electrically Released Brake Units Enclosed UniModules Specifications Component Inertia WR (lb.ft. ) FBB MBFB Static Max. Total Armature Hub Shaft NEMA Size Voltage DC Torque (lb.ft.) Speed (RPM) Weight (lbs.) (lb.ft. ) Hub Shaft Spliced Input Frame Size 50 90 6 3600 8.6.009.00.0005.00.0003 56C/48Y 00 90 3600 0.5.03.00.00.00.00 56C/48Y 80 90 3600 0.5.03.00.00.00.00 0 90 3 3600 7.08.06.06.06.007 8C/43TC 84C/45TC 3C/8TC 5C/84TC 3. Select Options Warner Electric Enclosed UniModules can be fitted with several accessories to extend their capacity and ease of mounting. 4. Select Control All electrically released modules require a control with a potentiometer that will vary brake channel output. For FBB and MBFB brake modules, the CBC-60, CBC-00, CBC-300, or CBC-500/550 is recommended. The FBC units require either a CBC-300 or a CBC 500/550 control. 6 Warner Electric 800-34-3369

Enclosed UniModules Electrically Released Brakes Selection/Ordering Information Selection Procedure Note: Care must be exercised when selecting the proper brake size for your application. The selection charts list NEMA motor frame sizes, motor shaft diameters, and the matching FBB or MBFB brakes. To select a brake:. Determine the motor NEMA C-face frame size.. Select brake configuration a. FBB to mount between a NEMA C-face motor and a gear reducer. b. MBFB to mount on double shafted NEMA C-face motors. 3. Select the brake model from the charts by the torque required higher torque for faster stopping, lower torque for longer, soft stopping. Note: Size 00 brakes are typically used on motors with a rating of HP or greater. 4. Important: Verify that the motor shaft diameter and mounting bolt circle dimensions are the same for the brake selected and the motor. Control Selection An optional conduit box enclosure is available. All electrically released units require a control with a potentiometer to vary brake channel output. For FBB and MBFB brake modules, control models CBC-60, CBC-00, CBC-300, or CBC- 500/550 are recommended. (See Controls Section.) Frame Size FBB MBFB NEMA Bolt Hole Motor to Motor Brake EUM Size Frame Size Mounting Circle Reducer Shaft Dia. Shaft Dia. EUM-50 56C 5 7/8 5/8 5/8 EUM-00 56C 5 7/8 5/8 5/8 EUM-80 43TC 45TC 5 7/8 7/8 7/8 EUM-0-7/8 3TC 5TC 7 /4 N/A 7/8 EUM-0 8TC 84TC 7 /4 /8 /8 EUM-5 3TC 5TC 7 /4 3/8 N/A How to Order. Specify model number and voltage or the corresponding part number.. Specify conduit box, if desired. See the Controls Section. 3. Specify required control unit. See the Controls Section. EUM Description EUM Model No. Static Torque (lb.ft.) Part No. FBB Brake Module (90VDC) Ordering Example EUM-50-0FBB-6, 90V or 5370-69-983; 5370-0-04 conduit box; CBC-60- control. EUM-50-0FBB-6 6 5370-69-983 EUM-50-0FBB-0 0.5 5370-69-986 EUM-00-0FBB- 5370-69-989 EUM-00-0FBB- 5370-69-99 EUM-80-0FBB- 5370-69-995 EUM-80-0FBB- 5370-69-998 EUM-0-0FBB-3 3 537-69-078 EUM-0-0FBB-56 56 537-69-08 EUM-5-0FBB-3 3 537-69-086 EUM-5-0FBB-56 56 537-69-090 EUM-50-0MBFB-6 6 5370-69-965 EUM-50-0MBFB-0 0.5 5370-69-968 EUM-00-0MBFB- 5370-69-97 MBFB EUM-00-0MBFB- 5370-69-974 Motor Brake Module EUM-80-0MBFB- 5370-69-977 (90VDC) EUM-80-0MBFB- 5370-69-980 EUM-0-7/8-0MBFB-3 3 537-69-064 EUM-0-7/8-0MBFB-56 56 537-69-068 EUM-0-0MBFB-3 3 537-69-056 EUM-0-0MBFB-56 56 537-69-060 Accessories Description FBB Size Part No. Conduit Box FBB series All sizes 5370-0-04 Motor Mount Kit 50/00/80 5370-0-0 for 0 FBB 0/5 537-0-0 Warner Electric 800-34-3369 7

Electrically Released Brakes EUM-FBB Brake Module EUM-FBB Series C B A D E P Optional Conduit Box T F N K L G H J M /" conduit hole both ends S R All dimensions are nominal, unless otherwise noted. Size A Max. B C Max. D E Max. F G Dia. H Dia. 3/8-6 UNC-A 50 5.88 3.5.500.000.56 (4) Equally Spaced 6.688.65 on 5.875 Dia. 3/8-6 UNC-A 00 5.66 3.5.500.000.56 (4) Equally Spaced 6.688.65 on 5.875 Dia. 3/8-6 UNC-A 80 5.66 3.5.500.000.56 (4) Equally Spaced 6.688.875 on 5.875 Dia. /-3 UNC-A 0 7.578 4.609.594.500.33 (4) Equally Spaced 9.344.5 on 7.50 Dia. /-3 UNC-A 5 7.578 4.609.594.500.33 (4) Equally Spaced 9.344.375 on 7.50 Dia. Size J Key K Min. L Pilot Dia. M Dia. N P R S Integral Key T 50 3/6 x 3/6 x -/4.83 4.500.65 30.88 45 3/6 x 3/6 3.5 00.3/6 x 3/6 x -/4.89 4.500.65 30.88 45 3/6 x 3/6 3.5 80 3/6 x 3/6 x -/4.89 4.500.875 30.88 45 3/6 x 3/6 3.5 0 /4 x /4 x.500 8.500.5 5.88 45 /4 x /4 3.5 5 5/6 x 5/6 x.500 8.500.375 5.88 45 5/6 x 5/6 3.5 8 Warner Electric 800-34-3369

EUM-MBFB Series Electrically Released Brakes EUM-MBFB Motor Brake Module E A B C Optional Conduit Box J F K D I G H /" conduit hole both ends All dimensions are nominal, unless otherwise noted. H Max. Size A B C Max. D E Max. F G Dia. Dia. Length Integral Key I J K 50 3.5.000.56.9.300 3/8-6 UNC-A 6.688.65.094 3/6 x 3/6 30.88 3.5 00 3.5.000.56.9.300 3/8-6 UNC-A 6.688.65.094 3/6 x 3/6 30.88 3.5 80 3.5.000.56.9.500 3/8-6 UNC-A 6.688.875.063 3/6 x 3/6 30.88 3.5 0-7/8" 4.609.500.33.50.594 /-3 UNC-A 9.344.875.766 3/6 x 3/6 30.88 3.5 0 4.609.500.33.50.594 /-3 UNC-A 9.344.5.766 /4 x /4 30.88 3.5 Warner Electric 800-34-3369 9

Electrically Released Brakes Electro Module, Electrically Released Brakes and Clutch/Brake Units for Dynamic Stopping and Cycling Applications Electro Modules NEMA C-face compatible design Never needs adjustment; automatically compensates for wear. Holding torque provided by powerful ceramic type permanent magnets. Complete torque control for soft starts and stops or instantaneous engagement. Rugged precision cast housing Brake automatically engages when power fails. UL Listed and CSA Certified Shaft Mounted Units FBB Brake Module FBC Brake Module for use with a clutch MBFB Motor Brake Module Warner Electric s unique design employs powerful permanent magnets for maximum torque when power is removed from the brake coil. A small amount of electrical power applied to the brake coil nullifies the permanent magnets force and the brake releases. No springs to limit cycle rates. Never nay adjustment. No lubrication. These brakes are recommended for dynamic cycling operations only. Specifications Available in Three Design Styles EM-FBB Brake Module Use for brake alone applications. Mounts between a C-face motor and a gear box or reducer. Available in five sizes. EM-MBFB Motor Brake Module Mounts to the back of a double shafted motor. Available in four sizes. EM-FBC Brake Module for use with a Clutch Combine with a motor or input clutch for clutch/brake applications. Three sizes are available. Component Inertia WR (lb.ft. ) Static Torque (lb.ft.) Max. Total Armature NEMA Size Voltage DC Brake Clutch Speed (RPM) Weight (lbs.) FBB/MBFB FBC Hub Shaft Frame Size EM-50 4 90 0.5 6 3600 8.6.007.04.003.00 56C/48Y EM-00 90 3600 0.5.08.004.00 56C/48Y EM-80 EM-0 4 8C/43TC 30 3600 0.5.08.036.004.00 90 84C/45TC 4 3C/8TC 56 95 3600 7.08.6.07.07 90 5C/84TC 30 Warner Electric 800-34-3369

Electro Modules Electrically Released Brakes EM-FBB, EM-FBC, EM-MBFB Selection Warner Electric Electrically Released Electro Modules are available in three styles. The EM-FBB Brake Module is used in brake only applications and mounts between a C-face motor and a gear box or reducer. The EM-MBFB Motor Brake Module mounts to the back of a double shafted motor. The EM-FBC Brake Module is combined with a motor clutch (EM-0) or an input clutch (EM-30) for clutch/electrically released brake applications. Note: Care must be exercised when selecting a brake to ensure it is sized properly for your application.. Select Configuration a. For FBB and MBFB Modules NEMA C-face Mounting Size EM-00 modules utilize a 5/8" diameter shaft to fit 56C/48Y motor frames with components of EM-80 units for higher torque and heat dissipation capacity than the EM-50 Select Brake Configuration: use an EM- FBB for mounting between a motor and a reducer; or an EM-MBFB for mounting on the rear of a double shafted motor. NOTE: When selecting an MBFB, ensure the shaft dimensions on the rear of the motor are compatible with the EM-MBFB unit selected. b. For FBC Modular Units, NEMA C-face Mounting Verify that brake will be cycled frequently, and will be used with a motor mounted clutch (EM-0) for C-face mounting. Determine the NEMA C-face frame size of your motor and/or reducer, and choose the corresponding size Electro Module from the Frame Size Selection chart. FBC Frame Size Selection NEMA EM Frame Size Size EM-50* 56C/48Y EM-00** 8C/43TC 84C/45TC EM-80 3C/8TC 5C/84TC EM-0 For torque ratings, refer to the Specifications chart. Note that separate torque ratings are listed for the clutch and brake segments of the module. * For 56C/48Y C-frame motors 3/4 HP and smaller, the EM-00 size may be used where extended life is desirable. ** The EM-00 size is recommended for motors HP and larger. c. For FBC Modular Units, Base Mounting Verify that the brake will be cycled frequently. Determine the NEMA C-face frame size of your motor and/or reducer, and choose the corresponding size Electro Module from the Frame Size Selection chart. FBB AND MBFB Frame Size Selection NEMA Frame Size 56C/48Y 8C/43TC 84C/45TC 3C/8TC 5C/84TC EM Size EM-50* EM-00** EM-80 EM-0 3TC/5TC EM-5 *For 56C/48Y C-frame motors 3/4 HP and smaller, the EM-00 size may be used where extended life is desirable. **The EM-00 size is recommended for motors HP and larger. Horsepower vs. Shaft Speed HP /4 / 3/4 -/ 3 5 7-/ Verify that brake will be cycled frequently, and will be used with an input clutch (EM-30) for base mounting. Select the correct size module from the Horsepower vs. Shaft Speed chart (at the bottom of this page) by determining the motor horsepower and RPM at the module location. The correct size EM is shown at the intersection of the HP and operating speed. For additional sizing information, refer to the technical sizing procedure (step ). SHAFT SPEED AT CLUTCH (IN RPM) 00 00 300 400 500 600 700 800 900 000 00 00 500 800 000 400 3000 3600 EM-50 EM-00 or EM-80 EM-0 or EM-5 Warner Electric 800-34-3369 3

Electrically Released Brakes Electro Modules. Determine Technical Requirements Technical considerations for sizing and selection are torque and heat dissipation. Each merits careful consideration, especially heat dissipation as over time, use in excessive temperature environments will have an adverse effect on bearing life and coil wire insulation integrity. Compare the calculated torque requirement with the average dynamic torque ratings. Select a unit with adequate torque. If the unit selected on torque is different than the unit selected based on heat, select the larger size unit. a. Heat Dissipation Sizing Friction surfaces slip during the initial period of engagement and, as a result, heat is generated. The clutch/brake selected must have a heat dissipation rating greater than the heat generated by the application. Therefore, in high inertia or high cycle rate applications, it is necessary to check the heat dissipation carefully. Inertia, speed and cycle rate are the required parameters. Heat dissipation requirement is calculated as follows: E =.7 x WR x (N/00) x F where: E = Heat (lb. ft./min.) WR = Total reflected inertia at the clutch/brake shaft. Include the clutch/brake output inertia. (lb.ft. ) N = Speed in revolutions per minute. (RPM) F = Cycle rate in cycles per minute (CPM) Compare the calculated heat generated in the application to the unit ratings using the heat dissipation curves. Select the appropriate unit that has adequate heat dissipation ability. Heat Dissipation Curves Heat Dissipation (ft. lbs./min.) Heat Dissipation (ft. lbs./min.) Heat Dissipation (ft. lbs./min.) Size 50 000 0000 8000 6000 4000 000 Size 00/80 8000 5000 000 9000 6000 3000 0 Size 0/5 36000 30000 4000 8000 000 6000 0 Maximum Speed 3600 RPM Maximum Speed 3600 RPM 0 900 800 700 3600 Speed (RPM) Maximum Speed 3600 RPM 50 F 00 F 0 0 900 800 700 3600 Speed (RPM) 50 F 00 F 50 F 00 F 0 900 800 700 3600 Speed (RPM) b. Torque Sizing For most applications, the correct size clutch/brake can be selected from the Horsepower vs. Shaft Speed chart on page 3. Determine the motor horsepower and the RPM at the clutch/brake. The correct size unit is shown at the intersection of horsepower and shaft speed. If the static torque requirements are known, refer to the technical ratings chart to select a unit. For some applications, the torque requirement is determined by the time allowed to accelerate and decelerate the load. (This time is generally specified in milliseconds.) For these applications, it is necessary to determine the torque requirement based on load inertia and the time allowed for engagement. The torque requirements are calculated as follows: T = (WR x N) / (308 x t) where: T = Average Dynamic Torque (lb. ft.) WR = Total reflected inertia at the clutch/brake shaft. Include the clutch/brake output inertia. (lb. ft. ) N = Speed in revolutions per minute. (RPM) t = Time allowed for the engagement (sec) 3 Warner Electric 800-34-3369

Electro Modules Electrically Released Brakes C-face Electrically Released Brakes Dynamic Torque Curves Dynamic Torque - (lb.ft.) Dynamic Torque - (lb.ft.) Dynamic Torque - (lb.ft.) Size 50 6 4 0 8 6 4 Size 00/80 3 8 4 0 6 8 4 0 0 Size 0/5 96 Maximum Speed 3600 RPM Static Torque 0.5 lb.ft. 50% Current 0 0 900 800 700 3600 84 7 60 48 36 4 0 0 00% Current Speed Difference in RPM Maximum Speed 3600 RPM Static Torque lb.ft. Speed Difference in RPM 50% Current 900 800 700 3600 Maximum Speed 3600 RPM Static Torque 56 lb.ft. 50% Current 00% Current 00% Current 900 800 700 3600 Speed Difference in RPM 3. Select Accessories Warner Electric Electro Modules can be fitted with several accessories to extend their capacity and ease of mounting. 4. Select Control All electrically released modules require a control with a potentiom eter that will vary brake channel output. For FBB and MBFB brake modules, the CBC-60, CBC-00, CBC-300, or CBC-500/550 is recommended. The FBC units require either a CBC-300 or a CBC 500/550 control. How to Order. Specify model number and voltage or the corresponding part number.. Specify conduit box, if desired. See the Controls Section. 3. Specify required control. See the Controls Section. Ordering Example EM-50-0FBB, 90V or 5370-69-058; 5370-0-04 conduit box; CBC-60- control. EM Description EM Model No. Voltage DC Part No. EM-50-0FBB 4 5370-69-066 EM-50-0FBB 90 5370-69-058 FBB EM-00-0FBB 4 5370-69-00 Brake EM-00-0FBB 90 5370-69-084 Module EM-80-0FBB 4 5370-69-068 for use as EM-80-0FBB 90 5370-69-059 brake only EM-0-0FBB 4 537-69-03 EM-0-0FBB 90 537-69-09 EM-5-0FBB 4 537-69-00 EM-5-0FBB 90 537-69-054 EM-50-0FBC 4 5370-69-065 FBC EM-50-0FBC 90 5370-69-056 Brake EM-00-0FBC 4 5370-69-09 Module EM-00-0FBC 90 5370-69-08 for use with EM-80-0FBC 4 5370-69-067 EM clutch EM-80-0FBC 90 5370-69-057 EM-0-0FBC 4 537-69-03 EM-0-0FBC 90 537-69-08 EM-50-0MBFB 4 5370-69-063 EM-50-0MBFB 90 5370-69-060 MBFB EM-00-0MBFB 4 5370-69-007 Motor EM-00-0MBFB 90 5370-69-085 Brake EM-80-0MBFB 4 5370-69-069 Module EM-80-0MBFB 90 5370-69-06 EM-0-7/8-0MBFB 4 537-69-0 EM-0-7/8-0MBFB 90 537-69-07 EM-0-0MBFB 4 537-69-033 EM-0-0MBFB 90 537-69-030 Accessories Description EM Size Part No. Conduit Box Base Mount Kit for 030 FBC Motor Mount Kit for 0 FBB, 00 FBC EM series All sizes 5370-0-04 50/00 5370-0-036 80 5370-0-037 0/5 537-0-09 50/00 5370-0-00 80 5370-0-0 0/5 537-0-0 Warner Electric 800-34-3369 33

Electrically Released Brakes EM-0 FBB Brake Module EM-FBB Series C B A D E P F G K L N /" NPT H M J S R All dimensions are nominal, unless otherwise noted. Size A Max. B C Max. D E Max. F G Dia. H Dia. J K Min. L Pilot Dia. M Dia. N P Min. R S Key 3/8-6 UNC-A 3/6 x 50/00 5.88 3.5.500.000.56 (4) Equally Spaced 6.688.65 3/6 x.83 4.500.65 30 36 45 3/6 x 3/6 on 5.875 Dia. -3/8 3/8-6 UNC-A 3/6 x 80 5.66 3.5.500.000.56 (4) Equally Spaced 6.688.875 3/6 x.89 4.500.875 30 36 45 3/6 x 3/6 on 5.875 Dia. -3/8 /-3 UNC-A /4 x 0 7.578 4.609.594.500.33 (4) Equally Spaced 9.344.5 /4 x.500 8.500.5 5 36 45 /4 x /4 on 7.50 Dia. /-3 UNC-A 5/6 x 5 7.578 4.609.594.500.33 (4) Equally Spaced 9.344.375 5/6 x.500 8.500.375 5 36 45 5/6 x 5/6 on 7.50 Dia. 34 Warner Electric 800-34-3369

EM-FBC Series Electrically Released Brakes EM-0FBC Brake Module for use with a Clutch C B Electrical Connection A D E Q F G K L P /" NPT H M J S N Mounting accessory plate R All dimensions are nominal, unless otherwise noted. Size A Max. B C Max. D E Max. F G Dia. H Dia. J K Min. L Pilot Dia. M Dia. N Max. P Q Min. R S Key 3/8-6 UNC-A 3/6 x 3/6 x 50/00 5.88 3.5.500.000.56 (4) Equally Spaced 6.688.65 3/6 x.83 4.500.65.53 30 36 45 3/6 on 5.875 Dia. -3/8 3/8-6 UNC-A 3/6 x 3/6 x 80 5.66 3.5.500.000.56 (4) Equally Spaced 6.688.875 3/6 x.89 4.500.875.53 30 36 45 3/6 on 5.875 Dia. -3/8 /-3 UNC-A /4 x /4 x 0 7.578 4.609.594.500.33 (4) Equally Spaced 9.344.5 /4 x.500 8.500.5.797 5 36 45 /4 on 7.50 Dia. Warner Electric 800-34-3369 35

Electrically Released Brakes EM-0 MBFB Motor Brake Module EM-MBFB Series E A B C /" NPT F D J I G H All dimensions are nominal, unless otherwise noted. H Size A B C Max. D E Max. F G Dia. Diameter Max. Length Required Key Size I J Min. 50/00 3.5.000.56.9.300 3/8-6 UNC-A 6.688.65.094 3/6 x 3/6 30 36 80 3.5.000.56.9.500 3/8-6 UNC-A 6.688.875.063 3/6 x 3/6 30 36 0-7/8" 4.609.500.33.50.594 /-3 UNC-A 9.344.875.766 3/6 x 3/6 30 36 0 4.609.500.33.50.594 /-3 UNC-A 9.344.5.766 /4 x /4 30 36 36 Warner Electric 800-34-3369

NEMA Frame Standards Ordering Information AH S R BF ES AJ U AK T BB BF Specifications AH AJ AK BB BF ES R S T U Shaft Mtg. Bolt Mtg. Flange Pilot Mtg. Bolt Keyway Depth Over Keyway Mtg. Bolt Shaft Module Size Length Center Dia. Pilot Dia. Depth Size, Qty. Length Keyway Width Ref. Dia. 50.06 5.875 4.500 5/3 00.06 5.875 4.500 5/3 80.04 5.875 4.500 5/3 0.56 7.50 8.500 5/6 5 3. 7.50 8.500 5/6 3/8-6 UNC 4 @ 90 3/8-6 UNC 4 @ 90 3/8-6 UNC 4 @ 90 /-3 UNC 4 @ 90 /-3 UNC 4 @ 90 Note: Warner Electric Modules are designed to comply with the NEMA frame standards for mounting. Reference to each particular frame size is given in the individual selection tables for each type of Warner Electric module. -/4.57 3/6 45.65 -/4.57 3/6 45.65 -/4.77 3/6 45.87 5.986 /4 45.5.0 5/6 45.375 Warner Electric 800-34-3369 37

Electrical Data/Coil Ratings EC/EB-375 EC EB Voltage DC 90 4 6 90 4 6 Resistance @ 0 C Ohms 453.5 9.3.0 446.8 9.3.96 Current Amperes.98.8.85.0.8 3.07 Watts 7 0 7 8 0 8 Coil Build-up milliseconds 6 60 59 50 60 5 Coil Decay milliseconds 3 4 5 8 4 0 EC/EB-000 EC EB Voltage DC 90 4 6 90 4 6 Resistance @ 0 C Ohms 48.7 9.7.3 48.7 9.7.3 Current Amperes.36. 4.87.36. 4.87 Watts 33 9 9 33 9 9 Coil Build-up milliseconds 50 35 0 35 0 05 Coil Decay milliseconds 70 75 80 70 75 80 EC/EB-475 EC EB Voltage DC 90 4 6 90 4 6 Resistance @ 0 C Ohms 368.9 37.8.3 443. 8.8.05 Current Amperes.44.64.58.03.88.93 Watts 5 6 8 8 Coil Build-up milliseconds 9 9 90 80 75 70 Coil Decay milliseconds 8 7 6 8 9 9 EC/EB-5 EC EB Voltage DC 90 4 6 90 4 6 Resistance @ 0 C Ohms 07.3 5..04 6.7.3.33 Current Amperes.43.59 5.79.34.08 4.5 Watts 39 38 35 3 6 7 Coil Build-up milliseconds 500 490 480 460 445 435 Coil Decay milliseconds 0 30 40 90 60 40 EC/EB-650 EC EB Voltage DC 90 4 6 90 4 6 Resistance @ 0 C Ohms 5 7.7.6 57. 8.3.4 Current Amperes.4.36 5.9.35.3 4.84 Watts 36 33 3 3 3 9 Coil Build-up milliseconds 0 5 0 08 05 Coil Decay milliseconds 0 0 0 3 4 ATC, ATTC, ATB, ATTB-5 ATC ATB Voltage DC 6 4 90 6 4 90 Resistance @ 0 C Ohms.37 0. 90.37 0. 90 Current Amperes 4.38.9.3 4.38.9.3 Watts 6.3 8.6 7.9 6.3 8.6 7.9 Coil Build-up milliseconds 45 45 45 45 45 45 Coil Decay milliseconds 8 8 8 9 9 9 FB/ER-375, 475, 650 FB-375 FB-475 FB-650 Voltage DC 90 4 90 4 90 4 Resistance @ 0 C Ohms 446 9 30 35 6 Current Amperes.0.8.300.09.380.46 Watts 8 9 7 6 34 34 Coil Build-up milliseconds 40 40 80 80 90 90 Coil Decay milliseconds 5 0 8 0 0 0 ATC, ATTC, ATB, ATTB-55 ATC ATB Voltage DC 6 4 90 6 4 90 Resistance @ 0 C Ohms. 9.6 30. 9.6 30 Current Amperes 4.96..39 4.96..39 Watts 9.8 9.3 35. 9.8 9.3 35. Coil Build-up milliseconds 00 00 00 0 0 0 Coil Decay milliseconds 0 0 0 35 35 35 ER-85, 5 ER-85 ER-5 Voltage DC 90 35-75 Resistance @ 0 C Ohms 304 35 Current Amperes.9.383 Watts 6 35 Coil Build-up milliseconds 400 700 Coil Decay milliseconds 0 0 ATC, ATTC, ATB, ATTB-5 ATC ATB Voltage DC 6 4 90 6 4 90 Resistance @ 0 C Ohms.0 6.5 8.0 6.5 8 Current Amperes 5.9.46.50 5.9.46.50 Watts 35.4 35 44.6 35.4 35 44.6 Coil Build-up milliseconds 45 45 45 50 50 50 Coil Decay milliseconds 40 40 40 45 45 45 EC/EB-85 EC EB Voltage DC 90 4 6 90 4 6 Resistance @ 0 C Ohms 0.9.098 3.3 0.4.7 Current Amperes.407.5 5.464.4.8 4.74 Watts 37 8 33 36 8 8 Coil Build-up milliseconds 5 00 80 70 70 70 Coil Decay milliseconds 30 5 80 75 70 38 Warner Electric 800-34-3369

Electrical Data Coil Ratings UM/EM/UMFB/EMFB UM/EM UMFB/EMFB Clutch Brake Clutch Brake Clutch Brake Brake 90 90 4 4 6 6 90 Voltage DC EM-50 45 45 3.8 3.8.86.86 446 Resistance EM-00 39 39 6.7 6.7.80.80 30 (ohms) EM-80 39 39 6.7 6.7.80.80 30 EM-0/5 48 48 7.9 7.9.. 05 EM-50.99.99.755.755 3.3 3.3.0 Amperes EM-00.30.30.896.896 3.30 3.30.300 EM-80.30.30.896.896 3.30 3.30.300 EM-0/5.363.363.34.34 4.90 4.90.380 EM-50 8 8 8 8 9 9 8 Watts EM-00.5.5 0 0 7 EM-80.5.5 0 0 7 EM-0/5 33 33 3 3 30 30 34 EM-50 5 53 5 53 5 53 40 Build-up EM-00 7 75 7 75 7 70 80 (millisecond) EM-80 7 75 7 75 7 70 80 EM-0/5 0 00 0 00 0 00 90 EM-50 6. 5.0 6. 5.0 6.5 5.0 5 Decay EM-00 0 0 0 8 (millisecond) EM-80 0 0 0 8 EM-0/5 0 0 0 0 0 0 0 Warner Electric 800-34-3369 39

Application Data Form Mail or FAX to: Warner Electric Brake and Clutch Application Engineering 449 Gardner Street, South Beloit, Illinois 6080 Phone number: 800-85-9050 FAX number: 85-389-58 Date Company Address City State Zip Name Title Phone ( ) Application: New Existing Torque required: oz. in. lb. in. lb. ft. Desired life: Static Dynamic Cycles Months Years Prime mover: Environmental ambient temp: F Frame size H.P. Speed of: Additional comments about application or sketch: Clutch/Brake Reducer ratio Belt/Chain ratio Linear velocity Load inertia to be accelerated and/or decelerated (WR ): State units How is clutch/brake to be controlled? On/off Torque adjust OEX Switching method? PLC Relay Sensor System friction: lb. in. oz. in. Distant moved per cycle: degrees Total single cycle time: Maximum cycle rate: Per min. Per hour Per day 40 Warner Electric 800-34-3369

Clutch and Brake Controls Contents Warner Electric s electronic controls are designed to provide simple setup and maximum performance when used with electric clutches and brakes. Our controls offer a range of functions from on-off to torque control to over-excitation. Selection Many parameters beyond function can impact control selection. Warner Electric produces a variety of control options to suit numerous application requirements. Control selection parameters include: Mounting Location Panel or conduit box mounting Switching Relay switching of A.C. or D.C. lines or solid state switching Output Voltage Controls are available for 6, 4 and 90 VDC clutch/brake coils Input Voltage Controls with input power transformers are available for connection to high voltage mains. If your application requires something special, please call us. We will be happy to provide solutions. Clutch and Brake Controls......................... 4 On-Off Controls CBC-00.......................................... 44 CBC-50.......................................... 44 CBC-60.......................................... 45 CBC-80.......................................... 46 CBC-80.......................................... 47 CBC-400.......................................... 48 CBC-450.......................................... 49 Adjustable Torque Controls MCS-03-........................................ 50 MCS-805-........................................ 5 MCS-805-........................................ 5 CBC-00.......................................... 5 CBC-300.......................................... 5 CBC-500.......................................... 53 CBC-550.......................................... 54 CBC-85R........................................ 56 Overexcitation Controls CBC-700.......................................... 58 CBC-750.......................................... 60 Closed Loop Position Control CBC-000......................................... 6 Appendix......................................... 64 Questions & Answers............................. 65 Warner Electric 800-34-3369 4

Clutch and Brake Controls Functions On-Off (Basic start-stop) Many applications are controlled by energizing the clutches and brakes with their rated D.C. voltages. Warner Electric controls are available with various mounting, input voltage and switching options. Control Type On-Off Conduit Box Mount Adjustable Torque (Soft start-stop) The torque transmitted by a clutch or brake is proportional to the coil current. Warner Electric offers several products that provide torque control for smooth and repeatable starts and stops. Adjustable Accel-Decel (Soft start-stop with full torque) Warner Electric offers a control that allows for adjustment of the acceleration and deceleration time ramps to achieve a repeatable soft start or stop while still allowing for full torque. On-Off Octal Socket Mount On-Off Panel Mount Adjustable Torque Overexcitation (Rapid cycling) The clutch/brake speed of response can be increased for improved accuracy and performance through overexcitation, which is the application of a short high voltage pulse to provide nearly instantaneous torque. Adjustable Accel-Decel Position Loop (Programmable cycling) Warner Electric s CBC-000 position loop control system offers servo system performance with electric clutch/brake economy in high accuracy indexing applications. The unique error correction capability of the CBC-000 to achieve repeatability and accuracy makes this an ideal control for many applications. Overexcitation Position Loop 4 Warner Electric 800-34-3369

Clutch and Brake Controls Torque A.C. D.C. Customer Supplied Model No. of Control Input Output Over- Switching Page Number Channels Channels Voltages Voltages Excitation Options Description Number CBC-00- No 0 90 No Relay A.C. Single channel control to CBC-00- No 0/40 mount inside standard 44 conduit box CBC-50- No 0 90 No Relay A.C. Dual channel control CBC-50- No 0/40 for clutch/brake to 44 mount inside module conduit box CBC-60-0 Single channel control with CBC-60-0/40 90 No Relay A.C. torque adjust for module 45 electrically released brakes CBC-80- No 0 90 No Relay D.C. Dual channel control for CBC-80-0/40 clutches and/or brakes 46 CBC-80 No 0 90 No Transistor or Dual channel control with Relay D.C. transistor switching 47 CBC-400-90 No 0 90 No Dual channel control for CBC-400-4 No 4-30 4 No Transistor or use with clutches 48- CBC-450-90 No 0/0/40/380/480 90 No Relay D.C. and/or brakes; 49 CBC-450-4 No 0/0/40/380/480 4 No Emergency stop input and AUX power supply MCS-03-0 90 No Relay D.C. Dual channel control with torque adjust 50 for one channel MCS-805-0/40 35-75 No Relay D.C. Single adjustable channel control 5 MCS-805- for use with ER-5 brake. CBC-00 0 90 No Transistor or Dual channel control with Relay D.C. one adjustable current 5 and one fixed voltage CBC-300 0 90 No Transistor or Dual channel adjustable 5 Relay D.C. current control CBC-500-90 0 90 No Dual channel control for two CBC-500-4 4-30 4 No Transistor or clutches and/or brakes with 53- CBC-550-90 0/0/40/380/480 90 No Relay D.C. two torque adjust channels; 55 CBC-550-4 0/0/40/380/480 4 No Emergency stop input CBC-85-R 0 90 No Transistor or Dual channel adjustable Relay D.C. time ramp with short 56 circuit protection CBC-700-90 No 0 90 Yes Transistor or Dual channel compact CBC-700-4 4 8 4 Relay D.C. overexcitation control for 58 4 or 90 volt clutches and brakes CBC-750-6-4-90 0/0/40 6,4,90 Yes Transistor, Dual channel full function Relay D.C. or overexcitation control; 60 Triac A.C. provides input/output logic, torque adjustable current and remote inputs CBC-000 N.A. 0/30 N.A. N.A. N.A. Error correction control to be used with one of 6 the above Warner Electric 800-34-3369 43

CBC-00, CBC-50 Integral/Conduit Box Mounted Controls On-Off Controls The CBC-00 and CBC-50 series are UL listed, conduit box mounted controls for 90 volt clutches and brakes. Models are available for either 0 VAC or 0/40 VAC input. CBC-00 series Single unit capacity The CBC-00 mounts inside a standard Warner Electric conduit box and includes rectification and suppression circuits. Specifications CBC-00- CBC-00- CBC-50- CBC-50- Part No. 6003-448-0 6003-448-03 6004-448-00 6004-448-00 0 VAC 0/40 VAC 0 VAC 0/40 VAC Input 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 90 VDC full wave 90 VDC half wave 90 VDC full wave 90 VDC half wave Output rectified rectified.8 Amp max..8 Amp Dual.8 Amp Dual.8 Amp Ambient -0 to 3 F (-9 to 45 C) Temperatures Switching External to control, accomplished on A.C. line using relay or triac. SPST SPST SPDT SPDT Solid State (maximum 40 VAC, 80 VAC, 40 VAC, 80 VAC, leakage Amp min. Amp min. Amp min. Amp min. current < ma) Electro- 0 VAC, 40 VAC, 0 VAC, 40 VAC, mechanical Amp min. Amp min. Amp min. Amp min. and Compact Single channel Mounts inside conduit box Connection diagrams CBC-00-, - FUSE CBC-00-0 VAC HOT CBC-00-0/40 VAC NEUTRAL SWITCH BLACK/ RED USER FURNISHED WHITE CBC-00 RED RED/WHITE 90 VOLT Dimensions CBC-00-, - 0.65" 0.66" DIA. MOUNTING HOLE FOR #6 SCREW 0.65".8" MAX..34" MAX. CBC-50-, - CBC-50-, - CBC-50 series Dual channel capacity The CBC-50 replaces the cover on the standard module conduit box (part no. 5370-0-04). Provides rectification and suppression for two devices. Green LED indicates power to clutch. Red LED indicates power to brake. CBC-50-0 VAC HOT CBC-50-0/40 VAC CBC-50-,- FUSE SWITCH BLACK/ CHANNEL RED RED + (RED) - USER FURNISHED NEUTRAL WHITE RED/WHITE CHANNEL BLUE/WHITE - (BLUE) + BLACK/ BLUE BLUE 90 VOLT CLUTCH OR BRAKE 0." MIN. 4 HOLES.88" 3.3" MAX..80".0" 0.56" MAX. and Dual channel All dimensions nominal unless otherwise specified..5" Replaces the cover on the module conduit box 44 Warner Electric 800-34-3369

On-Off Controls CBC-60 Integral/Electrically Released Motor Brake Controls CBC-60 The CBC-60 series clutch/brake controls provide a single 90 VDC adjustable output for use with any clutch/brake unit. The adjustable output will provide consistent and repeatable release for Warner Electric s 90 VDC permanent magnet electrically released brakes. The CBC-60 mounts as the cover on the standard module conduit box (part number: 5370-0-04). The 60- accommodates 0 volts A.C. motors. Adjustable 30-00 VDC LED indicator 0 volt A.C. input The power to the 60- control can come from either a 30 volt or 460 volt A.C. motor. Customer-provided switching is accomplished through the motor starter on the A.C. input. This allows convenient retrofit of spring-set style motor brakes and inexpensive installation of new applications. Adjustable 30-00 VDC Power from motor Easy retrofit 30/460 motors Dimensions 0.", 4 HOLES Connection Diagram 0 VAC 460 VAC T T T3 T7 T8 T9 T4 T5 T6 (MOTOR TERMINALS) 30 VAC T T T3 T7 T8 T9 T4 T5 T6 (MOTOR TERMINALS) 460 VAC T T T3 T7 T8 T9 T4 T5 T6 (MOTOR TERMINALS) Specifications HOT FUSE NEUTRAL WYE Connected Motor CBC-60-50 RED RED/WHITE 0 00 + - 90 VDC BRAKE CBC-60- BLACK/RED RED + 50 30 VAC 90 VDC BRAKE WHITE RED/WHITE - 30 VAC 30 VAC SWITCH BLACK/ RED USER FURNISHED DELTA Connected Motor CBC-60- WHITE BLACK/RED WHITE BLACK/RED WHITE CBC-60- Part No. 603-448-00 603-448-00 Input 0 VAC, 50/60 Hz 0/40 VAC, 60 Hz, Phase, 00 VA max. Status Indicator Output Ambient Temperatures Switching Red LED indicates power to the brake Single Channel, 30-00 VDC half-wave rectified nominal, 0.8 Amps maximum 0 to F (-8 to 50 C) Accomplished through motor starter or on A.C. line using relay or triac 0 00 CBC-60-50 RED/WHITE 0 00 CBC-60-50 RED RED RED/WHITE 0 00 + - + - 90 VDC BRAKE 90 VDC BRAKE 30 VAC.8"." T T T3 T7 T8 T9 T4 T5 T6 30 VAC BLACK/RED WHITE CBC-60-50 RED + RED/WHITE 0 00-90 VDC BRAKE (MOTOR TERMINALS).88" 3.30" 0.56".5" All dimensions nominal unless otherwise specified. Warner Electric 800-34-3369 45

CBC-80 Plug-in Octal Socket Power Supplies On-Off Controls The CBC-80 is a basic on-off power supply that provides full voltage to a 90 volt clutch or brake and is activated by an external switch. This type of power supply is sufficient for many clutch/brake applications. CBC-80 series Multi-unit capacity The CBC-80 is a plug-in power supply which is used with an octal socket. The wiring connections are made at the socket. The CBC-80 will operate two units separately or simultaneously. Octal socket is purchased separately. For basic on-off operation Wiring connections made at octal socket Arc suppression circuitry extends switch life Fused for overload protection LED output indicators DIN rail mountable Specifications Dimensions.968" ±.03" SQ..78" ±.03" STD. OCTAL KEYED PLUG.437" ±.06" CBC-80- CBC-80- Part No. 600-448-004 600-448-006 Input Voltage 0 VAC, 50/60 Hz 0/40 VAC, 50/60 Hz Output 90 VDC,.5 A max. Circuit Protection Ambient Temperature Max. Cycle Rate Switching Status Indicator Mounting Fused.6 Amp, 50 V fast-blo -3 to 6 F (-3 to 47 C) Limited by the clutch or brake, variable with application Single pole, double throw Minimum contact rating: 0 Amp, 8 VDC resistive or 0 Amp, 0 VAC inductive Red LED indicates brake is energized, Green LED indicates clutch is energized Two versions of octal socket are available: 600-0-00 foot mount 600-0-00 DIN rail mount Connection Diagram OCTAL SOCKET.57" (39.9) DIN RAIL MOUNT SOCKET.39" (60.7).70" (7.8).7" (8) NEUTRAL 0 VAC 50/60 Hz HOT Connection diagram for operating clutch/brake separately. 90 V CLUTCH 6 5 4 3 OCTAL SOCKET 7 + 8 90 V BRAKE STOP SWITCH START USER FURNISHED.57" (39.9).40" (6) All dimensions nominal unless otherwise specified. NEUTRAL 0 VAC 50/60 Hz HOT 90 V CLUTCH 6 5 4 3 OCTAL SOCKET + 7 8 Connection diagram for operating clutch/brake simultaneously. SWITCH USER FURNISHED 90 V BRAKE 46 Warner Electric 800-34-3369

On-Off Controls CBC-80 Plug-in Octal Socket Power Supplies Specifications CBC-80 PLC compatible The CBC-80 is a power supply with solid state circuits for load switching. A brake and clutch may be operated separately or, two brakes or two clutches, one unit on at a time. The CBC-80 mounts on an octal socket (purchased separately), and the wiring connections are made at the socket terminals. Octal socket sold separately, refer to mounting specifications for part number. Plug-in power supply with solid state switching circuits increases switch service life Adjustable time delay for controlling clutch/brake overlap Internally fused for overload protection DIN rail mountable CBC-80 Part No. 600-448-00 Input Output Status Indicator Circuit Protection Ambient Temperature Leakage Current Max. Cycle Rate Switching Adjustments Mounting: Connection Diagram NEUTRAL 0 VAC 50/60 Hz HOT 0 VAC, 50/60 Hz 90 VDC, 0.5 A max. Red LED indicates brake energized. Green LED indicates clutch energized. Fused 0.5 Amps, 50 V -0 to 3 F (-9 to 45 C) 500 ua max. for solid state switches Limited by the clutch or brake, variable with application Momentary contact, maintained contact, or solid state open collector logic Minimum contact rating 0 VDC resistive, 0.0 Amps Minimum input pulse millisecond Externally adjusted potentiometer sets overlap between clutch and brake from 0 to 30 MS. Two versions of octal socket are available: 600-0-00 foot mount 600-0-00 DIN rail mount 6 ST SWITCH USER FURNISHED 90 V BRAKE OCTAL SOCKET OP 90 V CLUTCH 5 4 3 7 8 LED output indicators Dimensions 3.56".437" OCTAL SOCKET.70" (7.8) 3.75".57" (39.9).39" (60.7) DIN RAIL MOUNT SOCKET.7" (8) STD. OCTAL KEYED PLUG.06" All dimensions nominal unless otherwise specified..57" (39.9).40" (6) Warner Electric 800-34-3369 47

CBC-400 Panel Mounted Control Specifications CBC-400-90 CBC-400-4 Part No. 6006-448-003 6006-448-00 Input Voltage 0 VAC 4-30 VAC Output Voltage 90 VDC 4 VDC Output Current Auxiliary Supply Circuit Protection Ambient Temperature Amp/Channel 5 Amps/Channel Amps Total 5 Amps Total VDC 50 ma Fused.5 Amp, 50 V fast-blo +3 to F (0 to 50 C) Status Indicators Red LED indicates channel is energized. Adjustments Inputs Connection Diagram SWITCHING CHANNEL INPUT (0-30 VDC) CHANNEL INPUT (0-30 VDC) CHANNEL OVERRIDE (0-30 VDC) AUXILIARY SUPPLY + VDC, 50 ma + + + + Fused 6.3 Amp, 50 V fast-blo Jumper for single or dual operation. See appendix for explanation. 3 Optically isolated, 0-30 VDC, 3-9 ma for Channel, Channel and Channel override (applies full voltage to channel output). 3 4 5 6 7 8 (CHANNEL LED) Single CBC-400 WARNER ELECTRIC POWER/OUTPUT (CHANNEL LED) 8 + CHANNEL 7 - (CLUTCH OR BRAKE) + 6 CHANNEL - (CLUTCH OR BRAKE) 5 J 4 Dual 3 } N/C NEUTRAL CBC-400-90 0 VAC HOT CBC-400-4 4-30 VAC All dimensions nominal unless otherwise specified. On-Off Controls CBC-400 series Dual channel controls The CBC-400 series is a basic on-off control which supplies 4 or 90 VDC for electric clutch/brake operation. They offer optically isolated switching inputs for start, stop, and emergency stop (E-stop). These controls can be set up to operate the two outputs alternately (single) or simultaneously (dual). Refer to the Appendix for additional setup and switching information. 4 or 90 Volt DC output Auxiliary V supply Fast coil suppression Single or dual channel operation Optically isolated input switching Enclosure (Optional) Lift off hinge Quick-release latches Conforms to NEMA Type 3 European Standard IEC 59, IP65 Dimensions.0" 3.90" Part No. 604-0-004 Size.5".75" 0.90".40".5" 8"H x 6"W x 4"D (03. x 5.4 x 0.6 mm).0" R 6.40" 6.00" 48 Warner Electric 800-34-3369

On-Off Controls CBC-450 series Dual channel control with transformer for variable input voltage The CBC-450 series is a basic on-off control which supplies 4 or 90 VDC for electric clutch/brake operation. They offer optically isolated switching inputs for start, stop, and emergency stop (Estop). These controls can be set up to operate the two outputs, alternately (single) or simultaneously (dual). Refer to the Appendix for additional setup and switching information. The CBC- 450 series has a power transformer which will operate with a 0, 0, 40, 380 or 480 VAC input. 4 or 90 Volt DC output Auxiliary V supply Specifications Fast coil suppression Single or dual channel operation Optically isolated switching Dimensions CBC-450 Panel Mounted Control Enclosure (Optional) Lift off hinge Quick-release latches Conforms to NEMA Type 3 European Standard IEC 59, IP65 Part No. 6006-0-007 Size 6"H x 6"W x 6"D (5.4 x 5.4 x 5.4 mm) CBC-450-90 CBC-450-4 Part No. 6006-448-006 6006-448-005 Input Voltage 0/0/40/380/480 VAC Output Voltage 90 VDC 4 VDC Output Current Auxiliary Supply Circuit Protection Ambient Temperature Status Indicators Adjustments Inputs Amp/Channel 4 Amps/Channel. Amps Total 4 Amps Total VDC 50 ma Fused.5 Amp +3 to F (0 to 50 C) Red LED indicates channel is energized. Fused 5 Amp Jumper for single or dual operation. See appendix for explanation. 3 Optically isolated, 0-30 VDC, 3-9 ma for Channel, Channel and Channel override (E-stop). 3.90" 4.60" 4.08" 4.50" Connection Diagram AC INPUT 480 VAC 380 VAC 40 VAC 0 VAC 0 VAC 0 VAC 3 4 5 6 SWITCHING CHANNEL INPUT (0-30 VDC) CHANNEL INPUT (0-30 VDC) CHANNEL OVERRIDE (0-30 VDC) AUXILIARY SUPPLY VDC, 50 ma + - + - + - + - CONNECT NEUTRAL TO TERMINAL 6 AND HOT TO CORRESPONDING AC INPUT VOLTAGE. 3 4 5 6 7 8 (CHANNEL LED) Single J CBC-450 WARNER ELECTRIC (CHANNEL LED) Dual 8 7 6 5 4 3 OUTPUT + CHANNEL - (CLUTCH OR BRAKE) + - } CHANNEL (CLUTCH OR BRAKE) N/C (DO NOT USE) 4.7".85" 3.50" All dimensions nominal unless otherwise specified. Warner Electric 800-34-3369 49

MCS-03- Adjustable Torque Control The MCS-03- is an enclosed control complete with a cover and mounting provisions. A brake and clutch may be operated separately with this control or up to four units, two at a time. The external wiring is connected to the terminal strip located behind the cover. Can be used with electrically released brakes Torque control for one 90 VDC clutch or brake Operates up to four units, two on at a time Easy-to-install. Compact. 0 VAC input Convenient terminal strip behind an easy-to-remove cover Adjustable Torque Controls Dimensions.75".75" 4.38".9" DIA. MTG. HOLES (4).56" 5.50" 6.63".50" CONDUIT SIZE BOTH SIDES.00".50" 3.00".69" All dimensions nominal unless otherwise specified. Specifications MCS-03- Part No. 600-448-00 Input Output Circuit Protection Ambient Temperature Maximum Cycle Rate Mounting External Switches (User furnished) 0 VAC, 50/60 Hz.5 Amp 90 V full wave rectified for one unit and adjustable from 0-90 volts full wave rectified for second unit Fused.5 Amp, 50 V -0 to 3 F (-9 to 45 C) Limited by the clutch or brake and will vary with application. Mounting centers 5-/" wide, 3" high. Knockouts for /" conduit Double pole, double throw maintained contact. Minimum contact rating: 0 Amp, 8 VDC resistive or 0 Amp, 0 VAC inductive. Contact ratings given will operate all Warner Electric brake and clutch units. However, switches with ratings less than those given may be used with fractional horsepower units provided the rating is equal to or greater than the coil current. Connection Diagrams (NEUT) (HOT) 0 VAC 50/60 Hz (USER FURNISHED) (NEUT) (HOT) 0 VAC 50/60 Hz (USER FURNISHED) Energize K, Brake released Energize K & K, Softstop Brake Full Brake On as shown 0 VAC 50/60 Hz SWITCH STOP 3 +90V SWITCH 3 +90V 3 +90V START 4 +ADJ. VOLTAGE 4 ADJ. VOLTAGE 4 ADJ. OUTPUT 5 6 TORQUE CONTROL 90 VOLT UNIT 7 CLUTCH ELECTRICALLY RELEASED BRAKE 5 6 7 + CLUTCH + BRAKE RHEOSTAT 000Ω 50W 600-0-00 (not included) K K 5 6 7 + - ELECTRICALLY RELEASED BRAKE 90 VOLT UNIT Normal Clutch/Brake Operation (One unit on at a time) Clutch/Electrically Released Brake Operation (Both units on at a time) Soft Stop for Electrically Released Brake 50 Warner Electric 800-34-3369

Power Supply MCS-805-, MCS-805- The DC voltage required to release the Warner Electric ER-5 Brake is supplied by the MCS-805- or MCS-805- Power Supply. The correct brake release voltage approximately 35-75 volts DC is set by adjusting the power supply at the time of brake installation. Temperature compensating circuits provide proper operation over the entire operating range of 0 F to 50 F. Switching may be provided on either the AC or DC side of the power supply. The MCS-805- may be mounted on its back panel or on /" conduit. The MCS-805- has a torque adjustment capability for soft stop applications. The MCS-805- requires two switching circuits when used for those applications requiring soft engagement. Specifications MCS-805- MCS-805- Part No. 6090-448-006 6090-448-007 Input 5/30 VAC, 50/60 Hz ±0% 5/30 VAC, 50/60 Hz ±0% Output 0.4 Amp, 35/75 VDC 0.4 Amp, 35/75 VDC Ambient Temperature -0 to 50 F (-9 to 65 C) -0 to 50 F (-9 to 65 C) Maximum Limited by the clutch or brake and will vary with application. Cycle Rate Consult factoryfor specifics. External Switches For DC switching: single pole, single throw. (User furnished) Minimum contact rating amp, 0 volts DC resistive. For AC switching: single pole, single throw. Minimum contact rating amp, 0 volts AC. Circuit Protection.75 Amp 50V Slow Blow 3 AG Dimensions FRONT SIDE 0.8 Diameter (4) Mtg Holes Clearance for.5" Screw BACK TOP AND BOTTOM 3.44 7.5 6.0.5.65 0.875 Diameter Knockouts for 0.50 Conduit Both Ends Typical 0.56 Connection Diagram Connect the MCS-805- or MCS-805- Power Supply per the following diagram and instructions: MCS 805-3 4 3 4 5.0 MCS 805-3 4 3.44 0.53 3.75 4.8 5.0 3 4 0 VAC S S Open brake engaged S 30 VAC 0 VAC S Closed brake released or tq. adj. mode per S 30 VAC 3 4 5 6 7 8 9 + AC INPUT 0/30 VAC 50/60 Hz S GND Brake DC Switching (Jumper if not used) For AC switching, switch may be in series with input supply. For DC switching, use terminals 7 and 8 as shown. DO NOT put switch in series with load on terminals 5 and 6. 3 4 5 6 7 8 9 + AC INPUT 0/30 VAC 50/60 Hz S GND Brake DC Switching Closed brake release Open brake in tq. adj. mode Warner Electric 800-34-3369 5

CBC-00, CBC-300 Single or Dual Channel Adjustable Torque Control Adjustable Torque Controls The CBC-00 and CBC-300 Controls provide single/dual torque control when connected to any of Warner Electric s 90 volt clutches and brakes. Common features and Current monitored output maintains consistent torque regardless of variation in coil temperature. Switch selection tunes control to exactly match power requirements and operating characteristics of each clutch or brake. Individual torque adjust allows preset maximum torque tailored to application requirements. Short circuit protection, line to line. Torque limiting protects machine components from damage. Can be used with electrically released brakes. Dimensions.500" (63.5).50" ±.00" NOM..60" (57. ±.54).095" (5.7).83" (7.8) REF. REF. (46.) NOM..063" (5.4) NOM. 5.87" ± (3.7 ±.508) 6.500" (65.) NOM..80" (.46) DIA. MTG. HOLE.00" 4.460" (3.3) NOM. CBC-00 Dual channel/single channel torque adjust The CBC-00 is a dual channel control with one adjustable current and one fixed voltage. Specifications CBC-00 CBC-300 Part No. 60-448-00 60-448-00 Input Power 0 VAC +0% -5%, 50/60 Hz, single phase, 5 VA max. Output Pulse-width modulated full wave rectified D.C. Constant current, switch selectable ranges, 0-90 volt Ambient +3 F to +3 F (0 C to 45 C) with plastic cover installed Temperature +3 F to +50 F (0 C to 66 C) with plastic cover removed Circuit Internal line to line short circuit protection Protection Optional customer supplied fusing on A.C. line,.5 Amps, 50 VAC. Fast-acting fuse recommended Current Adjust (via front panel Single adjustable channel Dual adjustable channels potentiometers) Status POWER green LED indicates A.C. power is applied to the indicators control. SHORT red LED indicates a short circuit condition exists on one or both outputs. Set DIP switches SW and SW to suit the current draw of the connected Internal Adjustments External Switching CBC-300 Dual channel/dual channel torque adjust The CBC-300 has two adjustable current channels. connected clutch/brake coil: Switch Range 3 4 5 Max Current Draw (ma) 60 75 45 305 533 Mechanical or electromechanical customer supplied: Amp, 5 V minimum rating Solid-state, NPN isolated transistor customer supplied: Amp, J50 V minimum rating. Maximum off state leakage current < ma.750" ±.00" (9. ±.508).345" ±.00" (34. ±.508).750" ±.00" (44.5 ±.54) Connection Diagram 0 VAC 50/60 Hz TB G H N G H N 3 4 5 6 7 8 9 + - + - CBC-300 IS ADJUSTABLE BOTH CHANNELS. OR CBC-00 IS FIXED VOLTAGE CHANNEL -/ A CH- CH- SW SW ADJUSTABLE VOLTAGE CHANNEL 5 Warner Electric 800-34-3369

Adjustable Torque Controls Specifications CBC-500-90 CBC-500-4 Part No. 604-448-003 604-448-00 Input Voltage 0 VAC 4-30 VAC Output Voltage 0-90 VDC 0-4 VDC Output Current Amp/Channel 5 Amps/Channel Amps Total 5 Amps Total Auxiliary Supply VDC 50 ma VDC 50 ma Circuit Fused Fused Protection.5 Amp, 50 V Fast-blo 6.3 Amp, 50 V Fast-blo Ambient Temperature +3 to F (0 to 50 C) Status Indicators Red LED indicates channel is energized. Two potentiometers for voltage adjustment of channel and channel output Adjustments from 0 to full rated voltage. Frequency adjustment from 60 to 400 Hz to reduce clutch/brake Hum associated with machine frequencies. Jumper for single or dual operation. See appendix for explanation. Inputs: 3 Optically coupled, 0-30 VDC, 3-9 ma for Channel, Channel and Channel override (applies full voltage to channel output) CBC-500 Panel Mounted CBC-500 series Dual torque adjustable power supplies The CBC-500 series is a dual channel adjustable voltage control with optically isolated input switching for 4 and 90 volt electric clutches and brakes. These controls can be set up to energize the two outputs alternately (single) or simultaneously (dual). Refer to the Appendix for additional setup and switching information. Dual adjustable channels Optically isolated input switching Single or dual channel operation Auxiliary V supply Can be used with electrically released brakes Enclosure (Optional) Lift off hinge Quick-release latches Conforms to NEMA Type 3 European Standard IEC 59, IP65 Connection Diagram SWITCHING CHANNEL INPUT (0-30 VDC) CHANNEL INPUT (0-30 VDC) CHANNEL OVERRIDE INPUT (0-30 VDC) AUXILIARY SUPPLY VDC, 50 ma + - + - + - + - 3 4 5 6 7 8 (CHANNEL LED) (CHANNEL ADJUST) J J Dual Single CBC-500 WARNER ELECTRIC (CHANNEL LED) (CHANNEL ADJUST) FREQUENCY ADJUST 8 7 6 5 4 3 + - + - } POWER/OUTPUT CHANNEL (CLUTCH OR BRAKE) CHANNEL (CLUTCH OR BRAKE) N/C (DO NOT USE) CBC-500-90 0 VAC CBC-500-4 4-30 VAC 0.0" 3.90" Part No. 604-0-004 Size Dimensions.75" 8"H x 6"W x 4"D (03. x 5.4 x 0.6 mm) 6.40" 6.00" All dimensions nominal unless otherwise specified. 0.90".40".5" Warner Electric 800-34-3369 53

CBC-550 Panel Mounted Adjustable Torque Controls CBC-550 series Dual adjustable with power transformer The CBC-550 series is a dual channel adjustable voltage control with optically coupled switching for 4 and 90 volt electric clutches and brakes. These controls can be set up to energize the two outputs alternately (single) or simultaneously (dual). Refer to the Appendix for additional setup and switching information. The CBC-550 series has a power transformer which will operate with a 0, 0, 40, 380, or 480 VAC input. Dual adjustable channels Optically isolated input switching Single or dual channel operation Can be used with electrically released brakes Specifications CBC-550-90 CBC-550-4 Part No. 604-448-006 604-448-005 Input Voltage 0/0/40/380/480 VAC Output Voltage 0-90 VDC 0-4 VDC Output Current Amp/Channel 4 Amps/Channel. Amps Total 4 Amps Total Auxiliary Supply VDC 50 ma VDC 50 ma Circuit Fused Fused Protection.5 Amp, 50 V fast-blo 5 Amp, 50 V fast-blo Ambient Temperature +3 to F (0 to 50 C) Status Indicators Red LED indicates channel is energized. Two potentiometers for voltage adjustment of channel and channel output Adjustments from 0 to full rated voltage. Frequency adjustment from 60 to 400 Hz to reduce clutch/brake Hum associated with machine frequencies. Jumper for single or dual operation. See appendix for explanation. Inputs 3 Optically coupled, 0-30 VDC, 3-9 ma for Channel, Channel and Channel override (applies full voltage to channel output) Enclosure (Optional) Lift off hinge Quick-release latches Conforms to NEMA Type 3 European Standard IEC 59, IP65 Part No. 6006-0-007 Size 6"H x 6"W x 6"D (5.4 x 5.4 x 5.4 mm) 54 Warner Electric 800-34-3369

Adjustable Torque Controls CBC-550 Panel Mounted Dimensions 4.60" 3.90" 4.08" 4.50" 4.7".85" 3.50" Connection Diagram AC INPUT 480 VAC 380 VAC 40 VAC 0 VAC 0 VAC 0 VAC 3 4 5 6 SWITCHING CHANNEL INPUT (0-30 VDC) CHANNEL INPUT (0-30 VDC) CHANNEL OVERRIDE (0-30 VDC) AUXILIARY SUPPLY VDC, 50 ma CONNECT NEUTRAL TO TERMINAL 6 AND HOT TO CORRESPONDING AC INPUT VOLTAGE. + - + - + - + - 3 4 5 6 7 8 (CHANNEL LED) (CHANNEL ADJUST) J J Dual Single CBC-550 WARNER ELECTRIC (CHANNEL LED) (CHANNEL ADJUST) FREQUENCY ADJUST All dimensions nominal unless otherwise specified. 8 7 6 5 4 3 OUTPUT + CHANNEL - (CLUTCH OR BRAKE) + - } CHANNEL (CLUTCH OR BRAKE) N/C (DO NOT USE) Warner Electric 800-34-3369 55

CBC-85R Panel Mounted Adjustable Torque Controls CBC-85R series The CBC-85R is designed to provide consistent and repeatable acceleration and deceleration when used with Warner Electric 90 VDC clutches and brakes. Current to each channel is introduced along an adjustable time ramp and monitored continuously. Adjustments include initial pull-in pulse, hold level, maximum torque, and ramp time. LEDs are provided on the circuit board to indicate power is applied to the clutch or brake unit. Note: It is recommended that the auto-gap springs be removed from the clutch and brake for successful accel-decel application. Specifications CBC-85R Part No. 85-448-00 Input Voltage Output Current Auxiliary Supply Circuit Protection Status Indicators Ambient Temperature Switching 0 VAC, 50/60 Hz, 00 VA maximum Current driven PWM, compatible with 90 VDC clutch/brake (switch selectable current output) VDC 50 ma Input Fused.5 Amp, 50 V fast-blo clutch and brake outputs are short circuit protected Clutch and brake LEDs indicate output is energized Short circuit LED indicates a fault 0 to F (-8 to 50 C) Contact rating: 5 ma @ 5 V, open collector NPN ma maximum allowable leakage current and V maximum saturation voltage Current Set-up Initial Pulse Adjustment Hold Level Adjustment Ramp Time Adjustment Time All dimensions nominal unless otherwise specified. Torque Adjustment 56 Warner Electric 800-34-3369

Adjustable Torque Controls CBC-85R Panel Mounted Dimensions 4.50" (4) 5.00" (7) 0.5" (6.4) 4.5" (08) 6.50" (65) 5.00" (7) 0.3" TYP. (7.9) 5.00" (7) 0.75" (9) 0.5"R TYP. (3.8) TOP VIEW BACK VIEW Connection Diagram HOLD LEVEL SET-UP SWITCH (Up: Normal, Down: Set-Up) CLUTCH SWITCH CLUTCH LED BRAKE LED SHORT CIRCUIT LED OPEN: CLUTCH CLOSED BRAKE SELECT OUTPUT INHIBIT COMMON 4 3 F U S E 7 6 5 4 3 0 VAC BRAKE CLUTCH + VDC CLUTCH INITIAL PULSE CLUTCH RAMP TIME CLUTCH HOLD LEVEL CLUTCH TORQUE ADJUST BRAKE RAMP TIME BRAKE HOLD LEVEL BRAKE TORQUE ADJUST BRAKE INITIAL PULSE FRONT VIEW Warner Electric 800-34-3369 57

CBC-700 General Purpose OEX Control Overexcitation Controls CBC-700 series Simple, compact, high performance OEX control for either 90 or 4 VDC clutches and brakes. OEX spike duration and anti-overlap times delay are adjustable. Two optically isolated inputs. High performance Switch selectable OEX duration Force decay suppression with adjustable anti-overlap time delay Compact, flexible mounting Models for 4 or 90 volt clutches and brakes Cycle rate limited by clutch/brake Specifications CBC-700-90 CBC-700-4 Part No. 604-448-003 604-448-00 Input 0 VAC, 50/60 Hz 4-8 VAC, 50/60 Hz Output Voltages Steady State 90 VDC 4 VDC Overexcitation 340 VDC 05 VDC Output Current (Per channel.5 Amps 3.5 Amps alternately) OEX Pulse Adjustable through logic board dip switches Duration (see service manual) Inputs Two-optically isolated (0-30 VDC) Ambient Temperature 0 F to 40 F (-8 C to +60 C) Range Maximum Off State Leakage < ma (inputs) Circuit Protection.5A Slo-Blo (5 x 0 mm) 5A Slo-Blo (5 x 0 mm) Auxiliary Supply VDC, 50 ma maximum Enclosure (Optional) Lift off hinge Quick-release latches Conforms to NEMA Type 3 European Standard IEC 59, IP65 Part No. 604-0-004 Size 8"H x 6"W x 4"D (03. x 5.4 x 0.6 mm) 58 Warner Electric 800-34-3369

Overexcitation Controls CBC-700 General Purpose OEX Control Dimensions 5.00" (.70).50" (.7) 3.5" (8.5) 4.65" (8.).50" (.7) All dimensions nominal unless otherwise specified..95" (4.).5" (3.)R TYP. Connection Diagram TYPICAL 3 WIRE SWITCHING CONFIGURATION HOT NEUTRAL 0 VAC 50/60 Hz AUXILIARY SUPPLY (+V) BRAKE INPUT (0-30VDC) CLUTCH INPUT (0-30VDC) + + + 3 4 5 6 7 8 CR SW 9 0 BK CL NOTE: CR, SW user furnished switch options for use with control. CR normally open relay contact SW normally open push button switch Warner Electric 800-34-3369 59

CBC-750 Rapid Acceleration/Deceleration Overexcitation Controls CBC-750 series Dual channel, current based OEX with switching logic Warner Electric s CBC-750 series of Constant Current Overexcitation Clutch/Brake Controls are solid-state electronic controls designed to increase the cycle rate capabilities and accuracies of electromagnetic clutches and brakes. The controls accomplish this by sending a momentary high voltage overexcitation spike to the clutch and/or brake magnetic coil to build a high density magnetic flux field almost instantaneously. By using overexcitation, the response time is reduced as dramatically as performance is increased. For example, the current build up time of a 5 inch, 6 volt magnet is reduced from 84 milliseconds to milliseconds. The CBC-750 user selects either 0, 0 or 40 VAC operation at the time of installation. Models for 6 volt, 4 volt, or 90 volt clutches and brakes are available. LED indicators on the faceplate of each control tell the user the status of input signals, output activation and any auxiliary inputs. A reset switch resets the output should a short be detected. Remote torque adjust potentiometer inputs are also provided. Appropriate current range for each size clutch or brake is selected by a dip switch. Constant current for each level is assured by the control s design. Specifications Shown with optional cover, part number 604-0-004 Maintains torque at preset levels regardless of temperature variations Automatically controls OEX pulse duration for optimum response without overheating coils Automatically prevents clutch and brake overlap Configurable as an analog follower control through remote top input Integral switching logic through auxiliary, inhibit and override inputs High performance OEX control Constant current output capability Models for 6, 4, and 90 V clutches and brakes Outputs short circuit protected. AC/DC optically isolated inputs Transformer isolation Remote torque potentiometer capability Input/Output inhibit functions Switch selectable OEX function Automatic CH/CH anit-overlap feature Heavy duty suppression circuits Selectable output current ranges Remote status indicators inputs and outputs CBC-750-6 CBC-750-4 CBC-750-90 Part No. 604-448-00 604-448-00 604-448-003 Input Power 0/0/40 VAC, ±0%, 50/60 Hz, 350 VA (switch selectable) Opto-isolated 0-30 VDC @ 0-35 ma nominal sinking or sourcing, or Control Inputs 4 VAC (50/60Hz) @ ma nominal, or 0 VAC (50/60 Hz) @ 0 ma nominal Clutch/brake Output Steady State Output Current controlled.90 to 4.34 A max..7 to.75 A max..060-.30 A max. Current Rise Time Dependent on clutch/brake size Current Fall Time Depending on clutch/brake size Overexcitation Voltage 75 VDC nom. 40 VDC nom. 450 VDC nom. Overexcitation Time Automatic adjustment by control feedback Anti-overlap Time Automatic adjustment by control feedback Power Supply Output VDC, ±0.6 VDC, 50 ma max. Auxiliary Indicator Opto-isolated NPN transistors Outputs 4 VDC maximum, 0 ma max., reverse polarity protected Circuit Protection Internal short circuit protection on each output channel. Fusing AC Input Line Amp, 50 V Slo-Blo OEX Supply 0 Amp, 3 V Slo-Blo 5 Amp, 50 V Slo-Blo Amp, 50 V Slo-Blo 60 Warner Electric 800-34-3369

Overexcitation Controls CBC-750 Rapid Acceleration/Deceleration Seven optically isolated inputs accept 0-30V A.C./D.C. (TB) or 0 VAC (TB3), configured through set-up switches. Channel Input. Channel Input Inhibit (disregards channel input signal) 3. Auxiliary Input 4. Channel Input 5. Channel Input Inhibit (disregards channel input signal) 6. Output Inhibit (deactivates both output channels) 7. Channel Override (applies full voltage to channel output) Connection Diagram Q CR Dimensions 3 4 5 6 7 3 4 5 6 7 Minimum Connection Diagram using DC inputs. TB COMMON CONNECTIONS TB 0-30 VDC CONNECTION TB5 3 4 5 6 7 8 + - NOTE: Q, CR user furnished switch options for use with control. Q NPN transistor CR normally open relay contact AUXILIARY SUPPLY VDC CHANNEL OPTIONAL REMOTE TORQUE POTENTIOMETER CHANNEL OPTIONAL REMOTE TORQUE POTENTIOMETER TB6 3 4 5 6 7 4.0" (355.85) 0/0/40 VAC 50/60 Hz CHANNEL (CLUTCH OR BRAKE) CHANNEL (CLUTCH OR BRAKE) 5.69" (44.53) 3.00" (330.0).50" (9.0) 9.77" (44.6) 7.50" (90.50) 9.56" 4.78" (4.8) (.4) All dimensions nominal unless otherwise specified..69" (68.33).5" (3.75).8" (5.54) DIA. MTG. HOLES (4) 3.00" (76.0) 3.6" (80.6) 0.75" (73.05).88" (.35) DIA. CONDUIT ENTRANCE (3) 3.09" (78.49)." (8.45) DIA. Setup Switches SW: AC Voltage selection switch on terminal board inside control unit Max. Current Output (SW7 & SW8 settings) Nominal Voltage 3 4 5 6 0.90.35 3.83 3.760 4.340 4 0.7 0.64 0.88 0.940.75 90 0.060 0.76 0.56 0.8 0.30 SW8 Channel current range selector (settings in diagram below) SW8 SW6 SW0 SW3 SW7 Channel current range selector (settings in diagram below) SW6 Channel OEX enable ( ) disable ( ) SW7 SW0 Channel input invert ( ) ( ) SW5 SW SW SW4 All switches are in the down ( ) position from factory Channel Torque Adjust (0-Full Voltage) Channel Torque Adjust (0-Full Voltage) SW3 Level/pulse selector level ( ) pulse ( ) SW5 Channel OEX enable ( ) / disable ( ) SW Channel local ( ) or remote ( ) torque adjust SW4 Channel local ( ) or remote ( ) torque adjust SW Auxiliary input selector Channel ( ) Channel ( ) Warner Electric 800-34-3369 6

CBC-000 System Accuracy CBC-000 Position-loop control with error correction compensation Warner Electric s CBC-000 is a closedloop positioning control with error compensation designed for industrial clutch/brake applications. The position loop is closed through encoder feedback which generates pulses proportional to load motion. The CBC-000 uses this feedback to determine the optimum brake actuation point. The control can be programmed to operate in one of two distinct modes: absolute or incremental. The CBC-000 includes eight solid state control outputs, a batch counter and a serial communications interface. The CBC-000 system consists of four key elements: the CBC-000, a clutch/brake, a clutch/brake control, and an encoder. Nearly any electric clutch/brake size and configuration can be used. The clutch/brake control should have solid-state compatibility. Simple onoff, soft start/stop, and overexcitation controls may all be utilized based on the desired velocity profile. Accessories Description Part Number Encoder Cable (Accessory) 6060-0-00 00 PPR Encoder w/0' cable 6060-0-00 50 PPR Encoder w/0' cable 6060-0-05 600 PPR Encoder w/0' cable 6060-0-060 00 PPR Encoder w/0' cable 6060-0-0 500 PPR Encoder w/0' cable 6060-0-50 5000 PPR Encoder w/0' cable 6060-0-500 (PPR Pulse Per Revolution) Serial Interface Module Specifications Part No. 6060-448-00 Closed Loop Position Control Input Power 00 to 30 VAC, 50/60 Hz, 0VA (00 to 60 VAC selectable) Auxiliary Supply VDC @ 75 ma Used for powering encoder, etc. Main Counter Range 6 Decades Reset Input External and front panel Count Rate (0 khz external input frequency) Batch Counter Range 6 Decades Reset Through front panel only Signal A and B Inputs Input Frequency D.C., 0 khz quadrature max. Input High Level 3.5 VDC min. Input Low Level.75 VDC max. Control Inputs Input Frequency D.C. to 0 Hz max. each input Input Type Single ended, current sinking Input Logic Both Edge and Level sensitive as defined by input use Input High Level 0 VDC min. to 0 VDC max. Input Low Level 0 VDC min. to VDC max. Input Current.5 ma steady state Display Decades 7 Decade, 0.6" red LED Decimal Point User programmable Range: xxx.xxx to xxxxxx Program Security Program LOCK of lines - 33 Control Outputs Type 8 Solid State 00 ma sink max., 4 VDC max. Serial Interface Type RS-4A/485 compatible Baud Rate Selectable: 300, 600, 00, 400 Parity Selectable: None, Odd, Even Data ASCII Diagnostics Mechanical Enclosure Weight Environmental Operating Temp. Storage Temp. Ambient Humidity Nine Self-Test Diagnostics Aluminum extrusion with molded VALOX bezel..5 lbs. 0 to +50 C (3 to F) -8 to 85 C (0 to 86 F) 90% and noncondensing Performs the necessary voltage level conversions to interface the RS-4A/485 output of the CBC-000 to RS-3C equipment. Part Number: 6060-0-3 6 Warner Electric 800-34-3369

Closed Loop Position Control CBC-000 CBC-000 Application Procedure. Select the proper clutch/brake Determine torque and inertia requirements Calculate heat dissipation for required cycle rate For best accuracy, mount clutch/brake directly on nip or drive shaft; avoid backlash. Select quadrature encoder Select encoder PPR for desired system resolution (i.e. inches/pulse, degrees/pulse, etc.) Determine input frequency; do not exceed 0,000 pulses/sec. Mount encoder directly to nip or drive shaft for best accuracy 3. Select clutch/brake power supply Use CBC-700 overexcitation control for best accuracy Use CBC-500/550 for soft starting and/or stopping Brake autogap may have to be removed for best accuracy 4. Plan system logic (switching requirements) Use absolute mode for indexing applications such as conveyors and turntables or cutoff applications where close registration is required Use incremental mode for cutoff applications Determine switching and relays required for machine operation 5. Select serial interface module if applicable. Timing Diagram Inputs: (Active Low) Outputs: (Momentary) (Edge Triggered) Velocity (Speed) Start Stop Start Early Warning Brake On Zero Speed Zero Speed + Delay Time 0 0 0 0 0 0 Zero Speed + Delay Time 0 Auxiliary Start 0 Start Point Early Warning Point Brake On Point 0 Delay Time Delay Time Braking Distance Time (Count) Operation Successful operation will require knowledge of the following definitions and their relationships to the timing diagram. Batch Complete 0 Function Key Definitions Count Move Present Early Warning Batch COUNT MOV PST 3 E.W. 6 BATCH The actual move distance, in pulses or scaled into engineering units (inches, feet, rotations, degrees, etc.) displayed dynamically. The desired move distance in pulses or scaled into engineering units. This is the value the opooerator enters to selecet a new move distance. A distance prior to Move Preset at which the early warning output is activated. Expressed as pulses or engineering units, this output can be used to accomplish a soft brake (slow down), energize valves, etc. A cumulative batch counter that can be dynamically displayed to show the number of operations, cycles, etc. When this counter reaches the value programmed by the Batch Preset (key 7) the Batch Complete Output is activated. The batch counter can be manually or automatically reset. Batch 7 A programmable batch counteractivates the batch complete output when the Preset BCH PST value programmed has been reached by the batch (key 6) Braking Distance 8 BRK DIS The actual distance required to stop. This value is dynamically updated to determine the brake actuation point. Factory default is 5 pulses or engineering units which is only used for the first cycle after power-up. After the first cycle thje CBC-000 will tune to the particular brake being utilized. The amount of cycles needed for tuning depends on how far the true braking distance value is from the default of 5. Warner Electric 800-34-3369 63

Appendix CBC-400/450/500/550 Single vs Dual Operation The CBC 400 and 500 series controls allow operation in either a single or dual mode. The mode of operation is determined via the position of a jumper on the main control board. The controls are shipped with the jumper in the J or single mode position. A variety of output logic can be accomplished via the single/dual jumper position and whether the control is wired to one input switching device (-wire mode) or two input switching devices (3-wire mode). The following diagrams show how each channel (output) of the control can be either alternately or simultaneously energized. -wire Switching Option Control s switching terminal block Channel Input Channel Input + + Switch (shown open) Jumper Mode Switch Channel Channel Auxiliary VDC Supply + 3 4 7 8 J Single J Dual Open Off Powered Closed Powered Off Open Powered Powered Closed Off Off CBC-500/550 Dual J J Jumper 3-wire Switching Option Control s switching terminal block CBC-400/450 Single Single Dual Channel Input Channel Input + + Auxiliary VDC Supply + 3 4 7 8 J Switch (shown open) Switch (shown open) Jumper Switch Switch Channel Channel Mode J Single J Dual Closed Open Latched On Off Open Closed Off Latched On Closed Open Off Off Open Closed Latched On Latched On 64 Warner Electric 800-34-3369

Questions and Answers. What transformers can be used with controls requiring 4-30 VAC input? Part Manufacturer Number Primary Secondary Abbott 6B -60 5 VAC 4V @ 6 amps Quality 6-K-9VBR 5/30 VAC 4V @ 8 amps Signal 4-6 5 VAC 4V @ 6 amps Signal DP4-6 5/30 VAC 4V @ 6 amps Triad F-60-U 5 VAC 4V @ 6 amps. When a single clutch or brake is used with a CBC-00 and no switch is used, a jumper wire is required across terminals 5 & 6 to get output at terminals 4 & 5. 4 5 6 7. Is the CBC-000 a stand-alone control? No. The CBC-000 provides closed loop feedback for a clutch/brake system. A common system will consist of four components: a Warner Electric brake and clutch a Warner Electric power supply an Encoder a CBC-000 position control The application criteria will determine which clutch/brake and which control will be appropriate selections. 8. Which of the controls would allow for the independent operation of two clutches or two brakes? Four controls allow for completely independent operation of two clutches or brakes. That is, that a clutch and brake can both be on at once, both off at once, or one on and one off. These controls are: CBC-80- and CBC-80-, MCS-03-, CBC-00, CBC-300 coil jumper wire 3. What is the difference between a MCS-80 and a CBC-80- or between a MCS-03 and a MCS-03-? There is no performance difference between the MCS-03 and MCS-03-. There is no performance difference between the MCS-80 and CBC-80-. The CBC-80- is roughly /4 shorter than the MCS-80. The units wire and work exactly the same. 4. Which power supplies can be used with the SF 55HT and SFC 55HT coil? The SF and SFC 55 High Torque clutch coils require.794 amps of current to provide full rated torque. The following power supplies and controls will provide the needed power. CBC-00.8 amps CBC-450 amp CBC-50.8 amps MCS-03-.5 amps CBC-80.5 amps CBC-500 amp CBC-400 amp CBC-550 amp 5. Can I use a CBC-60 with a variable frequency drive and AC motor? No. As the voltage to the drive is varied, the output to the electrically released brake would also vary. This would cause the brake to re-engage when it should be released. The CBC-400/450 and CBC-500/550 allow for operation of both channels on at once, both channels off at once or cycling between channel one and two. However, in the bothon/both-off mode, you cannot also do independent single channel operation. 9. Are there any controls that can be used to control the torque of a 90 volt clutch or brake via an analog signal input? Not currently. However, the TCS-00 and TCS-00- both provide signal following capabilities for use with units with 4 volt coils. These units can follow a 0 0 volt or 4 4 ma input signal. 0. Which controls can be used with electrically released brakes? The CBC-60- and CBC-60- are designed specifically to use with the conduit box of EM and EUM electrically released brake designs. The CBC-60- and CBC-60- can also be used with ER and FB brake designs. The MCS-03-, CBC-00, CBC-300 and CBC-500/550 can all be used with ER, FB as well as UM-FBC, EM and EUM-FBB and EM and EUM-MBFB designs. The MCS 805- and MCS 805- are for use only with the ER 5 brakes. The ERS series brakes can be used with the CBC-00 or CBC-80 power supplies. 6. Which power supplies offer a VDC power source that could be used to power auxiliary switch inputs such as inductive or photoelectric sensors? CBC-400, CBC-450, CBC-500, CBC-550, CBC-700, CBC-750 Warner Electric 800-34-3369 65

Ordering Information Model Part Number Page CBC-00-...6003-448-0...44 CBC-00-...6003-448-03...44 MCS-03-...600-448-00...50 CBC-50-...6004-448-00...44 CBC-50-...6004-448-00...44 CBC-60-...603-448-00...45 CBC-60-...603-448-00...45 CBC-00...60-448-00...5 CBC-300...60-448-00...5 CBC-400-4...6006-448-00...48 CBC-400-90...6006-448-003...48 CBC-450-4...6006-448-005...49 CBC-450-90...6006-448-006...49 CBC-500-4...604-448-00...53 CBC-500-90...604-448-003...53 CBC-550-4...604-448-005...54 CBC-550-90...604-448-006...54 CBC-85R...85-448-00...56 CBC-700-4...604-448-00...58 CBC-700-90...604-448-003...58 CBC-750-6...604-448-00...60 CBC-750-4...604-448-00...60 CBC-750-90...604-448-003...60 CBC-80-...600-448-004...46 CBC-80-...600-448-006...46 Octal Socket, Foot Mount...600-0-00...46,47 Octal Socket, DIN Rail Mount...600-0-00...46,47 CBC-80...600-448-00...47 CBC-000...6060-448-00...6 Serial Interface Module...6060-0-3...6 Encoders: Cable (Accessory)...6090-0-00...6 00 PPR...6060-0-00...6 50 PPR...6060-0-05...6 600 PPR...6060-0-060...6 00 PPR...6060-0-0...6 500PPR...6060-0-50...6 5000PPR...6060-0-500...6 Optional Enclosure: CBC-400, CBC-500, CBC-700...604-0-004...48, 53,58 Optional Enclosure CBC-450, CBC-550...6006-0-007...49, 54 MCS-805-...6090-448-006...5 MCS-805-...6090-448-007...5 66 Warner Electric 800-34-3369

Packaged Performance Products Service Parts Contents C-face Compatible Units Electro Modules EM Series Modular Clutches, Brakes and Motor Brakes.................... 69 UniModules UM Series Clutch and Clutch/Brake Combinations........................ 76 UM-C Series Ceramic Faced Clutch/Brakes............................. N/A Enclosed UniModules EUM Series Clutch and Clutch/Brake Combinations....................... 84 EUM-W Series Washdown Clutch/Brakes............................... 84 Shaft and Base Mounted Units Electro Clutches and Brakes EC Series Shaft Mounted Clutches.................................... 90 EB Series Shaft Mounted Brakes..................................... 96 Advanced Technology Clutches and Brakes ATC Series Clutches............................................... 0 ATB Series Brakes................................................ 04 Packaged Stationary Field Clutches SFP Clutches.................................................... N/A Electro Pack EP Series Base Mounted Clutch/Brakes................................ 06 EP-C Series Ceramic Faced Base Mounted Clutch/Brakes.................. N/A Electrically Released Brakes Spring-Set Brakes ERS Series Static Engaged Brakes.................................... N/A ERD Series Dual Purpose Engagement Brakes........................... N/A Permanent Magnet Brakes FB Series Shaft Mounted Brakes..................................... 4 ER Series Flange Mounted Brakes.................................... 6 EM UM-FBC Series Clutch/Electrically Released Brakes....................... 8 EM-FBB, EM-FBC, EM-MBFB Series Brake Modules...................... Bushing Part Numbers........................................... 35 Service Parts Warner Electric 800-34-3369 67

Replacement Service Parts When replacing components in clutches and brakes several guidelines are appropriate. In all cases, when replacing worn friction surfaces both the components need to be replaced. In many cases, the splined hubs should be inspected and replaced if worn. Common Replacement practices: EM/UM/EUM clutches Replace rotor and armature Inspect splined hub EM/UM/EUM clutch/brakes Replace clutch rotor and armature Replace brake magnet and armature Inspect splined hub EC clutches Replace clutch rotor and armature EB brakes Replace magnet and armature ATC clutches Replace clutch rotor facing and armature facing Inspect splined hub ATB brakes Replace magnet facing and armature facing Inspect splined hub Electro-Pack clutch/brake Replace clutch rotor and armature Replace brake magnet and armature Inspect splined hub Electrically released brakes On all Electrically released brakes the magnet and armature are only sold as a matched set and must be replaced as a set. A note on burnishing: When new friction surfaces are installed it will be necessary to burnish the unit prior to returning to full production rates. Burnishing is the act of wearing in the friction faces to ensure full engagement and therefore full torque. Burnishing is achieved by simply cycling the unit under less than full load (machine empty, if possible). Most units will achieve full torque in less than 00 cycles. Refer to the service manual for more details. Service Parts 68 Warner Electric 800-34-3369

EM Series Electro Module 0 Motor Clutch Module 3 5 5-3 5-4 4 5-5- EM-50 Only Note: As of June, 000 all rotors are manufactured as a single piece design. The rotor assembly part number remains the same and now includes the hub and set screws. Component Parts EM-50 EM-00 EM-80 EM-0 Item Description Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty. * Rotor Assembly w/fan & hub 5370-75-00 5370-75-03 5370-75-007 537-75-005 Field 6 volt 5370-45-0 5370-45-0 5370-45-0 537-45-00 4 volt 5370-45-04 5370-45-04 5370-45-04 537-45-03 90 volt 5370-45-0 5370-45-0 5370-45-0 537-45-0 3 Setscrew 797-047 4 4 Adapter 04-0096 Mounting Accessory 5370-0-08 5370-0-03 5370-0-03 537-0-008 5- Capscrew 797-093 4 797-093 4 797-093 4 797-078 4 5 5- Lockwasher 950-08 4 950-08 4 950-08 4 950-00 4 5-3 Capscrew 797-075 4 5-4 Lockwasher 950-003 4 *Shipped Assembled Refer to Service Manual P-3. These units meet the standards of UL 508 and are listed under guide card #NMTR, file #5964. These units are CSA certified under file #LR543. Service Parts Warner Electric 800-34-3369 69

Electro Module 0 Brake Module EM Series 6a 4-4 5 4 3 4 9 4-4- 8 4-3 5 6b 3 7 0 Service Parts 70 Warner Electric 800-34-3369

EM Series Electro Module 0 Brake Module Component Parts EM-50 EM-00 EM-80 EM-0 EM-5 Item Description Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty. Armature 5370--0 5370--03 5370--03 537--005 537--005 Armature Hub 540-638 540-684 540-64 540-074 540-039 3 Retaining Ring 748-0445 748-0676 748-0676 4 Lockwasher 950-037 6 950-037 6 5 Capscrew 797-008 6 797-008 6 6a Retaining Ring 748-03 748-00 748-00 748-0 748-0 6b Retaining Ring 748-03 748-00 7 Ball Bearing 66-049 66-00 66-00 66-04 66-04 Magnet 8 6 Volt 5370-63-008 5370-63-00 5370-63-00 537-63-00 4 Volt 5370-63-00 5370-63-005 5370-63-005 537-63-005 90 Volt 5370-63-007 5370-63-003 5370-63-003 537-63-003 537-63-003 9 Housing 535-030 535-03 535-03 535-0033 535-0033 0 Setscrew 797-047 4 797-047 4 797-047 4 797-047 4 797-047 4 Shaft 798-0045 798-07 798-0086 798-0050 798-068 Key - Output 590-009 590-009 590-009 590-009 590-04 3 Ball Bearing 66-055 66-043 66-043 66-044 66-044 Mounting Accessory 5370-0-07 5370-0-07 5370-0-03 537-0-007 537-0-007 4- Capscrew 797-0353 4 797-0353 4 797-0353 4 797-08 4 797-08 4 4 4- Washer 950-0354 4 950-0354 4 950-0354 4 950-0033 4 950-0033 4 4-3 Spacer 807-08 4-4 Collar 66-000 66-0003 66-0003 5 Key 590-0043 590-0084 590-0084 Key Accessory - Input 5370-0-07 5370-0-07 5370-0-07 537-0-043 537-0-044 Refer to Service Manual P-3. These units meet the standards of UL 508 and are listed under guide card #NMTR, file #5964. These units are CSA certified under file #LR543. Service Parts Warner Electric 800-34-3369 7

Electro Module EM-50-0MB, EM-80-0MB, EM-0-0MB EM Series 4 3 9-3 9-4 9-7 6 8 9 5 3 5 6 7 8 0 4 9-3 Spacer used only if module interferes with motor housing. Service Parts 7 Warner Electric 800-34-3369

EM Series Electro Module EM-50-0MB, EM-80-0MB, EM-0-0MB Component Parts EM-50 EM-80 EM-0 Item Description Part No. Qty. Part No. Qty. Part No. Qty. Fan Assembly 5370-04-00 5370-04-00 748-05 Follow-up Spring 808-004 808-007 808-009 3 Retaining Ring 748-0440 748-0450 748-0455 4 Armature 5370--0 5370--03 537--005 Magnet 5 6 Volt 5370-63-008 5370-63-00 537-63-00 4 Volt 5370-63-00 5370-63-005 537-63-005 90 Volt 5370-63-007 5370-63-003 537-63-003 6 Capscrew 797-008 6 7 Lockwasher 950-037 6 8 Retaining Ring 748-0445 9 Key 590-0043 590-0084 0 Splined Hub 540-646 540-647 540-04 Hub 540-08 540-076 540-00 Retaining Ring 748-03 748-00 748-0 3 Retaining Ring 748-0676 4 Bearing 66-049 66-00 66-04 5 Retaining Ring 748-0556 748-0555 748-0554 6 Housing 535-036 535-034 535-0050 7 Plug 680-008 680-008 680-007 8 Setscrew 797-047 4 797-047 4 797-047 4 Mounting Accessory 5370-0-07 5370-0-03 537-0-007 9- Capscrew 797-0353 4 797-0353 4 797-08 4 9 9- Lockwasher 950-0354 4 950-0354 4 950-0033 4 9-3 Spacer 807-08 9-4 Collar 66-000 66-0003 Key Accessory - Input 5370-0-073 5370-0-073 537-0-043 Refer to Service Manual P-3. These units meet the standards of UL 508 and are listed under guide card #NMTR, file #5964. These units are CSA certified under file #LR543. Service Parts Warner Electric 800-34-3369 73

Electro Module 30 Input Clutch Module EM Series 3 9 3-3- 4 5 6a 7 6b 4 8 0 3 Component Parts Service Parts 74 Warner Electric 800-34-3369 EM-50 EM-00 EM-80 EM-0 Item Description Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty. Rotor Assembly w/fan 5370-75-006 5370-75-009 5370-75-009 537-75-007 Capscrew 797-039 4 797-4 5 797-4 5 797-0083 6 3 Lockwasher 950-0436 4 950-0436 5 950-0436 5 950-037 6 4 Spacer 807-006 807-006 807-006 Field (with housing EM-50-30 only) 5 6 volt 5370-45-07 5370-45-007 5370-45-007 537-45-00 4 volt 5370-45-074 5370-45-005 5370-45-005 537-45-005 90 volt 5370-45-073 5370-45-008 5370-45-008 537-45-003 6a Retaining Ring 748-03 748-00 748-00 748-0 6b Retaining Ring 748-03 7 Ball Bearing 66-049 66-00 66-00 66-04 8 Retaining Ring 748-007 9 Housing 535-064 535-064 535-09 0 Setscrew 797-047 4 797-047 4 797-047 4 797-047 4 Shaft 798-0047 798-09 798-04 798-03 Ball Bearing 66-055 66-043 66-043 66-044 Mounting Accessory 537-0-00 3 3- Capscrew 797-075 4 3- Lockwasher 950-003 4 4 Key 590-009 590-009 590-009 590-009 Refer to Service Manual P-3. These units meet the standards of UL 508 and are listed under guide card #NMTR, file #5964. These units are CSA certified under file #LR543.

EM Series Electro Module 40 Output Clutch Module 3 3-3- 4 6 7 8 0 5 3 9 4 Component Parts EM-50 EM-00 EM-80 EM-0 Item Description Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty. Armature 5370--0 5370--03 5370--03 537--005 Capscrew 797-008 3 Lockwasher 950-037 6 4 Retaining Ring 748-0445 748-0676 748-0676 5 Hub 540-638 540-64 540-64 540-074 6 Retaining Ring 748-03 748-00 748-00 748-0 7 Ball Bearing 66-049 66-00 66-00 66-04 8 Retaining Ring 748-03 9 Housing 535-03 535-033 535-033 535-0034 0 Shaft 798-0046 798-08 798-0085 798-005 Key 590-009 590-009 590-009 590-009 Ball Bearing 66-055 66-043 66-043 66-044 Mounting Accessory 5370-0-07 5370-0-07 5370-0-07 3 3- Capscrew 797-0353 4 797-0353 4 797-0353 4 3- Lockwasher 950-0354 4 950-0354 4 950-0354 4 4 Key 590-0043 590-0084 590-0084 Key Accessory - Input 5370-0-07 5370-0-07 5370-0-07 537-0-043 Refer to Service Manual P-3. These units meet the standards of UL 508 and are listed under guide card #NMTR, file #5964. These units are CSA certified under file #LR543. Service Parts Warner Electric 800-34-3369 75

UniModule UM-00 Clutch/Brake Combination UM Series 6 7 3 4-3 0 4 4-4 4-5 9 8 8 5 4 3 6b 9 7 6a 0 4-4- 5 3 0 Service Parts 76 Warner Electric 800-34-3369

UM Series UniModule UM-00 Clutch/Brake Combination Component Parts UM-50 UM-00 UM-80 UM-0 UM-5 Item Description Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty. Armature Assembly 5370--0 5370--03 5370--03 537--005 537--005 Armature Hub 540-638 540-64 540-64 540-074 540-074 3 Retaining Ring 748-0445 748-0676 748-0676 4 Lockwasher 950-037 6 950-037 6 5 Capscrew 797-008 6 797-008 6 6a Retaining Ring 748-03 748-00 748-00 748-0 748-0 6b Retaining Ring 748-03 7 Ball Bearing 66-049 66-00 66-00 66-04 66-04 Magnet 8 6 volt 5370-63-008 5370-63-00 5370-63-00 537-63-00 537-63-00 4 volt 5370-63-00 5370-63-005 5370-63-005 537-63-005 537-63-005 90 volt 5370-63-007 5370-63-003 5370-63-003 537-63-003 537-63-003 9 Housing 535-065 535-06 535-06 535-063 535-063 0 Setscrew 797-047 4 797-047 4 797-047 4 797-047 4 797-047 4 Shaft 798-0046 798-08 798-0085 798-005 798-054 Key 590-009 590-009 590-009 590-009 590-04 3 Ball Bearing 66-055 66-043 66-043 66-044 66-044 Mounting Accessory 5370-0-040 5370-0-040 5370-0-040 537-0-00 537-0-00 4- Capscrew 797-378 4 797-378 4 797-378 4 797-440 4 797-440 4 4 4- Washer 950-0354 4 950-0354 4 950-0354 4 950-0 4 950-0 4 4-3 Adapter 807-08 04-03 04-03 4-4 Capscrew 797-44 4 797-44 4 4-5 Washer 950-00 4 950-00 4 5 Key 590-0043 590-0084 590-0084 6 Rotor Assembly 5370-75-09 5370-75-0 5370-75-07 537-75-0 537-75-03 (with fan and hub) Field (with housing) 7 6 volt 5370-45-06 5370-45-057 5370-45-057 537-45-07 537-45-07 4 volt 5370-45-064 5370-45-059 5370-45-059 537-45-09 537-45-09 90 volt 5370-45-063 5370-45-058 5370-45-058 537-45-08 537-45-08 8 Retaining Ring 748-00 748-00 748-00 748-0558 748-0558 9 Bearing 66-050 66-00 66-00 66-068 66-068 0 Retaining Ring 748-008 748-000 748-000 748-0067 748-0067 3 Conduit Box (Optional) 5370-0-04 5370-0-04 5370-0-04 5370-0-04 5370-0-04 4 Set Screw 797-098 797-0069 797-0069 797-098 797-098 Key 5370-0-07 5370-0-07 5370-0-07 537-0-043 537-0-044 Refer to Service Manual P-3. These units meet the standards of UL 508 and are listed under guide card #NMTR, file #5964. These units are CSA certified under file #LR543. Note: As of June, 000 all rotors are manufactured as a single piece design. The rotor assembly part number remains the same and now includes the hub and set screws. Service Parts Warner Electric 800-34-3369 77

UniModule UM-040 Clutch Combination UM Series - 3-3 3 5-4 -5 4 0 9 8 3 6 4 5 - - 8 9 0 7 Service Parts 78 Warner Electric 800-34-3369

UM Series UniModule UM-040 Clutch Combination Component Parts UM-50 UM-00 UM-80 UM-0 UM-5 Item Description Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty. Rotor Assembly 5370-75-09 5370-75-0 5370-75-07 537-75-0 537-75-03 (with fan and hub) Field (with housing) 6 volt 5370-45-06 5370-45-057 5370-45-057 537-45-07 537-45-07 4 volt 5370-45-064 5370-45-059 5370-45-059 537-45-09 537-45-09 90 volt 5370-45-063 5370-45-058 5370-45-058 537-45-08 537-45-08 3 Retaining Ring 748-00 748-00 748-00 748-0558 748-0558 4 Bearing 66-050 66-00 66-00 66-068 66-068 5 Retaining Ring 748-008 748-000 748-000 748-0067 748-0067 8 Armature Assembly 5370--0 5370--03 5370--03 537--005 537--005 9 Capscrew 797-008 6 797-008 6 0 Lockwasher 950-037 6 950-037 6 Retaining Ring 748-0445 748-0676 748-0676 Hub 540-638 540-64 540-64 540-074 540-074 3 Retaining Ring 748-03 748-00 748-00 748-0 748-0 4 Ball Bearing 66-049 66-00 66-00 66-04 66-04 5 Retaining Ring 748-03 6 Housing 535-067 535-068 535-068 535-069 535-069 7 Shaft 798-0046 798-08 798-0085 798-005 798-054 8 Key 590-009 590-009 590-009 590-009 590-04 9 Ball Bearing 66-055 66-043 66-043 66-044 66-044 0 Key 590-0043 590-0084 590-0084 Mounting Accessory 5370-0-040 5370-0-040 5370-0-040 537-0-00 537-0-00 - Capscrew 797-378 4 797-378 4 797-378 4 797-440 4 797-440 4 - Lockwasher 950-0354 4 950-0354 4 950-0354 4 950-0 4 950-0 4-3 Adapter 807-08 04-03 04-03 -4 Capscrew 797-44 4 797-44 4-5 Lockwasher 950-00 4 950-00 4 Conduit Box 5370-0-04 5370-0-04 5370-0-04 5370-0-04 5370-0-04 (Optional) 3 Set Screw 797-098 797-0069 797-0069 797-098 797-098 Key 5370-0-07 5370-0-07 5370-0-07 537-0-043 537-0-044 Refer to Service Manual P-3. These units meet the standards of UL 508 and are listed under guide card #NMTR, file #5964. These units are CSA certified under file #LR543. Note: As of June, 000 all rotors are manufactured as a single piece design. The rotor assembly part number remains the same and now includes the hub and set screws. Service Parts Warner Electric 800-34-3369 79

UniModule UM-030 Clutch/Brake Combination UM Series 5 3 3 0 9 8 7 4 6 3 4 3 5 9 8 0 7 6 4 3 30 7 8 9 6 5 Service Parts 80 Warner Electric 800-34-3369

UM Series UniModule UM-030 Clutch/Brake Combination Component Parts UM-50 UM-00 UM-80 UM-0 UM-5 Item Description Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty. Rotor Assembly w/fan 5370-75-006 5370-75-009 5370-75-009 537-75-007 537-75-007 Capscrew 797-94 4 797-4 5 797-4 5 797-0083 6 797-0083 6 3 Lockwasher 950-0436 4 950-0436 5 950-0436 5 950-037 6 950-037 6 4 Spacer 807-006 807-006 807-006 807-006 Field (with housing UM-50-030 only) 5 6 volt 5370-45-07 5370-45-007 5370-45-007 537-45-00 537-45-00 4 volt 5370-45-074 5370-45-005 5370-45-005 537-45-005 537-45-005 90 volt 5370-45-073 5370-45-008 5370-45-008 537-45-003 537-45-003 6 Retaining Ring 748-03 748-00 748-00 748-0 748-0 7 Ball Bearing 66-049 66-00 66-00 66-04 66-04 8 Retaining Ring 748-03 9 Retaining Ring 748-007 0 Housing 535-064 535-064 535-09 535-09 Setscrew 797-047 4 797-047 4 797-047 4 797-047 4 Shaft 798-0047 798-09 798-04 798-03 798-055 3 Bearing 66-055 66-043 66-043 66-044 66-044 4 Key 590-009 590-009 590-009 590-009 590-04 5 Armature Assembly 5370--0 5370--03 5370--03 537--005 537--005 6 Armature Hub 540-638 540-64 540-64 540-074 540-074 7 Retaining Ring 748-0445 748-0676 748-0676 8 Lockwasher 950-037 6 950-037 6 9 Capscrew 797-008 6 797-008 6 0 Retaining Ring 748-03 748-00 748-00 748-0 748-0 Retaining Ring 748-03 Ball Bearing 66-049 66-00 66-00 66-04 66-04 Magnet 3 6 volt 5370-63-008 5370-63-00 5370-63-00 537-63-00 537-63-00 4 volt 5370-63-00 5370-63-005 5370-63-005 537-63-005 537-63-005 90 volt 5370-63-007 5370-63-003 5370-63-003 537-63-003 537-63-003 4 Housing 535-065 535-06 535-06 535-063 535-063 5 Setscrew 797-047 4 797-047 4 797-047 4 797-047 4 797-047 4 6 Shaft 798-0046 798-08 798-0085 798-005 798-05 7 Key 590-009 590-009 590-009 590-009 590-04 8 Ball Bearing 66-055 66-043 66-043 66-044 66-044 9 Key 590-0043 590-0084 590-0084 30 Capscrew 797-0353 4 797-0353 4 797-0353 4 797-075 4 797-075 4 3 Lockwasher 950-0354 4 950-0354 4 950-0354 4 950-003 4 950-003 4 3 Conduit Box (Optional) 5370-0-04 5370-0-04 5370-0-04 5370-0-04 5370-0-04 Refer to Service Manual P-3. These units meet the standards of UL 508 and are listed under guide card #NMTR, file #5964. These units are CSA certified under file #LR543. Service Parts Warner Electric 800-34-3369 8

UniModule UM-3040 Clutch Combination Base Mounted UM Series 3 30 0 9 8 7 4 6 5 3 4 5 6 7 8 9 0 3 9 8 5 6 7 4 Service Parts 8 Warner Electric 800-34-3369

UM Series UniModule UM-3040 Clutch Combination Base Mounted Component Parts UM-50 UM-00 UM-80 UM-0 UM-5 Item Description Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty. Rotor Assembly w/fan 5370-75-006 5370-75-009 5370-75-009 537-75-007 537-75-007 Capscrew 797-94 4 797-4 5 797-4 5 797-0083 6 797-0083 6 3 Lockwasher 950-0436 4 950-0436 5 950-0436 5 950-037 6 950-037 6 4 Spacer 807-006 807-006 807-006 807-006 Field (with housing UM-50-3040 only) 5 6 volt 5370-45-07 5370-45-007 5370-45-007 537-45-00 537-45-00 4 volt 5370-45-074 5370-45-005 5370-45-005 537-45-005 537-45-005 90 volt 5370-45-073 5370-45-008 5370-45-008 537-45-003 537-45-003 6 Retaining Ring 748-03 748-00 748-00 748-0 748-0 7 Ball Bearing 66-049 66-00 66-00 66-04 66-04 8 Retaining Ring 748-03 9 Retaining Ring 748-007 0 Housing 535-064 535-064 4 535-09 535-09 Setscrew 797-047 4 797-047 4 797-047 4 797-047 4 Shaft 798-0047 798-09 798-04 798-03 798-055 3 Bearing 66-055 66-043 66-043 66-044 66-044 4 Key 590-009 590-009 590-009 590-009 590-04 5 Armature Assembly 5370--0 5370--03 5370--03 537--005 537--005 6 Capscrew 797-008 6 797-008 6 7 Lockwasher 950-037 6 950-037 6 8 Retaining Ring 748-0445 748-0676 748-0676 9 Hub 540-638 540-64 540-64 540-074 540-074 0 Retaining Ring 748-03 748-00 748-00 748-0 748-0 Ball Bearing 66-049 66-00 66-00 66-04 66-04 Retaining Ring 748-03 3 Housing 535-067 535-068 535-068 535-069 535-069 4 Shaft 798-0046 798-08 798-0085 798-005 798-05 5 Key 590-009 590-009 590-009 590-009 590-04 6 Ball Bearing 66-055 66-043 66-043 66-044 66-044 7 Key 590-0043 590-0084 590-0084 8 Capscrew 797-0353 4 797-0353 4 797-0353 4 797-075 4 797-075 4 9 Lockwasher 950-0354 4 950-0354 4 950-0354 4 950-003 4 950-003 4 30 Conduit Box (Optional) 5370-0-04 5370-0-04 5370-0-04 5370-0-04 5370-0-04 Refer to Service Manual P-3. These units meet the standards of UL 508 and are listed under guide card #NMTR, file #5964. These units are CSA certified under file #LR543. Service Parts Warner Electric 800-34-3369 83

Enclosed UniModule EUM-00 Clutch/Brake Combination EUM-W-00 Clutch/Brake Combination EUM/EUM-W Series 0 8 7 7a a Optional 0 0W 5 5W 4 3 9 5 4 Optional 6 7a 3 3a 3 W 8 a 6 6W 6a 7b EUM-W Modification 6W 6W 9 Spare Parts W 9a 4W Service Parts 84 Warner Electric 800-34-3369

EUM/EUM-W Series Enclosed UniModule EUM-00 Clutch/Brake Combination EUM-W-00 Clutch/Brake Combination Component Parts EUM-50 EUM-00 EUM-80 EUM-0 EUM-5 Item Description Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty. Armature Assembly 5370--0 5370--03 5370--03 537--005 537--005 Armature Hub 540-638 540-64 540-64 540-074 540-074 a Key 590-0043 590-0084 590-0084 3 Retaining Ring 748-0445 748-0676 748-0676 4 Lockwasher 950-0 6 950-0 6 5 Capscrew 797-008 6 797-008 6 6 Retaining Ring 748-03 748-00 748-00 748-0 748-0 7a Ball Bearing 66-049 66-00 66-00 66-04 66-04 7b Ball Bearing 66-055 66-043 66-043 66-044 66-044 8 Endbell/Brake 456-04 456-09 456-09 456-07 456-07 Brake Magnet 9 6 volt 5370-63-037 5370-63-00 5370-63-00 537-63-00 537-63-00 4 volt 5370-63-038 5370-63-005 5370-63-005 537-63-005 537-63-005 90 volt 5370-63-036 5370-63-003 5370-63-003 537-63-003 537-63-003 9a Set Screws 797-047 4 797-047 4 797-047 4 797-047 4 797-047 4 Clutch Field/Endbell Assembly 0 6 volt 5370-45-077 5370-45-086 5370-45-086 537-45-033 537-45-033 4 volt 5370-45-078 5370-45-087 5370-45-087 537-45-034 537-45-034 90 volt 5370-45-076 5370-45-085 5370-45-085 537-45-03 537-45-03 Rotor/Hub Assembly 5370-75-03 5370-75-035 5370-75-04 537-75-04 537-75-033 a Set Screws 797-098 797-0069 797-0069 797-098 797-098 Mounting Accessory Kit 5370-0-040 5370-0-040 5370-0-040 537-0-04 537-0-04 3 Cover Plate 686-055 686-055 686-055 686-055 686-055 3a Cover Plate Screws 797-0575 4 797-0575 4 797-0575 4 797-0575 4 797-0575 4 4 Center Housing 535-076 535-076 535-076 535-077 535-077 5 Conduit Box (optional) 5370-0-04 5370-0-04 5370-0-04 5370-0-04 5370-0-04 6 Shaft 798-0046 798-08 798-0085 798-005 798-054 6a Key 590-009 590-009 590-009 590-009 590-04 7 Retaining Ring 748-00 748-00 748-00 748-0558 748-0558 7a Ball Bearing 66-050 66-0300 66-0300 66-068 66-068 8 Retaining Ring 748-008 748-008 748-008 748-0067 748-0067 9 Assembly Bolts 797-433 797-433 797-433 797-438 797-438 0 Connector 80-0038 80-0038 80-0038 80-0038 80-0038 Accessory Fan (optional) 5370-0-055 5370-0-055 5370-0-054 537-0-09 N/A Washer 950-044 950-044 950-044 950-044 950-044 3 Insulator 57-037 57-037 57-037 57-037 57-037 EUM-W Unique Parts W Washdown Mounting Kit 5370-0-05 5370-0-05 5370-0-05 537-0-08 537-0-08 4W Center Housing for Washdown 535-08 535-08 535-08 535-08 535-08 5W Conduit Box Kit 5370-0-045 5370-0-045 5370-0-045 5370-0-045 5370-0-045 6W Shaft 798-063 798-065 798-06 798-059 798-067 0W Conduit Connector 80-0058 80-0058 80-0058 80-0058 80-0058 W Fan Kit (optional) 5370-0-060 5370-0-060 5370-0-06 537-0-033 N/A 6W Gasket/Seal Repair Kit 5370-0-058 5370-0-058 5370-0-058 537-0-03 537-0-03 Key 5370-0-07 5370-0-07 5370-0-07 537-0-043 537-0-044 Refer to Service Manual P-3. These units meet the standards of UL 508 and are listed under guide card #NMTR, file #5964. These units are CSA certified under file #LR543. Service Parts Warner Electric 800-34-3369 85

Enclosed UniModule EUM-040 Clutch Combination EUM Series 9 7 6 6a 0a Optional 0 9 4 3 8 5 4 Optional 6a 6a 7a 3 a 0 8 a 5 5a 7b Spare Parts Service Parts 86 Warner Electric 800-34-3369

EUM Series Enclosed UniModule EUM-040 Clutch Combination Component Parts EUM-50 EUM-80 EUM-0 Item Description Part No. Qty. Part No. Qty. Part No. Qty. Armature Assembly 5370--0 5370--03 537--005 Armature Hub 540-638 540-64 540-074 a Key 590-0043 590-0084 3 Retaining Ring 748-0445 748-0676 4 Lockwasher 950-0 6 5 Capscrew 797-008 6 6a Retaining Ring 748-03 748-00 748-0 6b Retaining Ring 748-03 7a Ball Bearing 66-049 66-00 66-04 7b Ball Bearing 66-055 66-043 66-044 8 Endbell 456-04 456-09 456-07 9 Clutch Field/Endbell Assembly 90 Volt 5370-45-076 5370-45-085 537-45-03 0 Rotor/Hub Assembly 5370-75-03 5370-75-04 537-75-04 0a Set Screws 797-098 797-0069 797-098 Mounting Accessory Kit 5370-0-040 5370-0-040 537-0-04 Cover Plate 686-055 686-055 686-055 a Cover Plate Screws 797-0575 4 797-0575 4 797-0575 4 3 Center Housing 535-076 535-076 535-077 4 Conduit Box (optional) 5370-0-04 5370-0-04 5370-0-04 5 Shaft 798-0046 798-0085 798-005 5a Key 590-009 590-009 590-009 6 Retaining Ring 748-00 748-00 748-0558 6a Ball Bearing 66-050 66-0300 66-068 7 Retaining Ring 748-008 748-008 748-0067 8 Assembly Bolts 797-433 797-433 797-438 9 Connector 80-0038 80-0038 80-0038 0 Accessory Fan (optional) 5370-0-055 5370-0-054 537-0-09 Washer 950-044 950-044 950-044 Insulator 57-037 57-037 57-037 Key 5370-0-07 5370-0-07 537-0-043 Service Parts Warner Electric 800-34-3369 87

Enclosed UniModule EUM-030 Clutch/Brake Combination EUM-W-030 Clutch/Brake Combination EUM/EUM-W Series 0 8 7 3 b a Optional 6a W 0 0W 9 8 5 5W 0a 9a 5 9 4 6 9a 5 4 6a 7 6b EUM-W Modification 8W 3 6a 4 Spare Parts 3a 3 () 8W a (6) 6 6W (8) 7W 4W Service Parts 88 Warner Electric 800-34-3369

EUM/EUM-W Series Enclosed UniModule EUM-030 Clutch/Brake Combination EUM-W-030 Clutch/Brake Combination Component Parts EUM-50 EUM-80 EUM-0 Item Description Part No. Qty. Part No. Qty. Part No. Qty. Armature Assembly 5370--0 5370--03 537--005 Armature Hub 540-638 540-64 540-074 a Key 590-0043 590-0084 3 Retaining Ring 748-0445 748-0676 4 Lockwasher 950-0 6 5 Capscrew 797-008 6 6a Retaining Ring 748-03 748-00 748-0 6b Retaining Ring 748-00 7 Ball Bearing 66-049 66-00 66-04 8 Endbell/Brake 456-04 456-09 456-07 Brake Magnet 9 6 volt 5370-63-037 5370-63-00 537-63-00 4 volt 5370-63-038 5370-63-005 537-63-005 90 volt 5370-63-036 5370-63-003 537-63-003 9a Set Screws 797-047 4 797-047 4 797-047 8 Field (with Endbell EUM-50 and EUM-80) 0 6 volt 5370-45-08 5370-45-090 537-45-00 4 volt 5370-45-083 5370-45-09 537-45-005 90 volt 5370-45-08 5370-45-089 537-45-003 0a Endbell (EUM-0 only) 456-08 Rotor 5370-75-033 5370-75-034 537-75-006 a Screw 797-94 4 797-4 5 797-008 6 b Washer 950-00 4 950-00 5 950-0 6 Shaft/Clutch 798-0047 798-04 798-03 3 Cover Plate 686-055 686-055 686-055 3a Screws 797-0575 4 797-0575 4 797-0575 4 4 Center Housing 535-076 535-076 535-077 5 Conduit Box (optional) 5370-0-04 5370-0-04 5370-0-04 6 Shaft/Brake 798-0046 798-0085 798-005 6a Key 590-009 590-009 590-009 7 Retaining Ring 748-03 748-00 748-0 8 Retaining Ring 748-007 748-00 9 Assembly Bolts 797-477 797-477 797-476 0 Connector 80-0038 80-0038 80-0038 Bearing 66-049 66-00 66-04 Bearing 66-055 66-043 66-044 3 Spacer 807-006 807-006 4 Bearing 66-055 66-043 66-044 5 Washer 950-044 950-044 950-044 6 Insulator 57-037 57-037 57-037 EUM-W Unique Parts W Shaft/Clutch 798-064 798-06 798-060 4W Center Housing for Washdown 535-08 535-08 535-08 5W Conduit Box Kit (optional) 5370-0-045 5370-0-045 5370-0-045 6W Shaft/Brake 798-063 798-06 798-059 0W Conduit Connector 80-0058 80-0058 80-0058 7W Washdown Mounting Kit 5370-0-05 5370-0-05 537-0-07 8W Gasket/Seal Repair Kit 5370-0-058 5370-0-058 537-0-03 Refer to Service Manual P-3. These units meet the standards of UL 508 and are listed under guide card #NMTR, file #5964. These units are CSA certified under file #LR543. Service Parts Warner Electric 800-34-3369 89

Electro Clutch EC-375, EC-475, EC-650 EC Series 7 8 9 A 7 7 0 3 4 A 4-8 5 6 6 3 4 5 7-4 - - -5 For information on Coil Data see page 38. -3 Electrical and Mechanical Data Static Max. Inertia WR (lb. ft ) Total Model Voltage Torque Speed Armature Outer Inner Weight Size DC (lb. ft.) RPM & Carrier Rotor Sleeve Sleeve lbs. 6 6 lb. ft. 5000.00.08.00.00 4 EC-375 4 6 lb. ft. 5000.00.08.00.00 4 90 6 lb. ft. 5000.00.08.00.00 4 6 30 lb. ft. 4500.07.033.006.00 8 EC-475 4 30 lb. ft. 4500.07.033.006.00 8 90 30 lb. ft. 4500.07.033.006.00 8 6 95 lb. ft. 3600.06.0.00.03 8 EC-650 4 95 lb. ft. 3600.06.0.00.03 8 90 95 lb. ft. 3600.06.0.00.03 8 Service Parts 90 Warner Electric 800-34-3369

EC Series Electro Clutch EC-375, EC-475, EC-650 Component Parts EC-375 EC-475 EC-650 Item Description Part No. Qty. Part No. Qty. Part No. Qty. Armature & Carrier Assembly 5380-0-006 58-0-003 58-0-003 - Capscrew 797-4 3 797-4 3 797-0086 3 - Lockwasher 950-00 3 950-00 3 950-00 3-3 Autogap Accessory 580-0-0 3 58-0-00 4 58-0-00 4-4 Carrier 5380-95-00 58-95-00 58-95-00-5 Armature 580--00 58--00 58--00 Inner Sleeve /" Bore 803-0054 5/8" Bore 803-0055 803-0044 3/4" Bore 803-004 7/8 Bore 803-0043 " Bore 803-0047 -/8" Bore 803-0049 -/4" Bore 803-0048 -3/8" Bore 803-0050 3 Screw 797-050 6 797-039 4 797-0083 4 4 Lockwasher 950-005 6 950-00 4 950-003 4 5 Retainer Plate 748-039 748-0393 748-0389 6 Rotor 580-75-00 58-75-00 58-75-00 7 Ball Bearing 66-049 66-009 66-00 8 Retainer ring 748-007 748-003 748-000 9 Outer Sleeve 580-04-00 58-04-00 58-04-00 0 Sleeve Bearing 66-077 66-079 66-078 Oil Seal 795-007 795-008 795-006 Retainer Ring 748-00 748-00 748-004 3 Ball Bearing 66-050 66-00 66-004 Field 6 volt 580-45-00 58-45-00 58-45-00 4 4 volt 580-45-004 58-45-004 58-45-004 90 volt 580-45-005 58-45-005 58-45-005 4- Terminal Accessory 503-0-00 503-0-00 53-0-00 5 Retainer Ring 748-008 748-000 748-0004 6 Set Collar 66-00 66-00 66-000 Accessory, W/Keys /" Bore 580-0-00 5/8" Bore 580-0-00 58-0-00 3/4" Bore 58-0-00 7 7/8" Bore 58-0-00 " Bore 58-0-00 -/8" Bore 58-0-00 -/4" Bore 58-0-00-3/8" Bore 58-0-00 8 Conduit Box 500-0-00 500-0-00 500-0-00 These units when used with the correct Warner Electric conduit box, meets the standards of UL508 and are listed under guide care #NMTR, file #5964. These units are CSA Certified under file #LR543. Refer to Service Manual P-0. Service Parts Warner Electric 800-34-3369 9

EC-85 Electro Clutch EC Series 0 c b 8 0 7 9 a 5 6 5 8 3 4 6 4 9 7 3 3 0 Service Parts 9 Warner Electric 800-34-3369

EC Series Electro Clutch EC-85 Component Parts EC-85 Item Description Part No. Qty. Armature Assembly 58--00 a Hub 540-98 b Autogap Accessory 50-0-068 3 c Armature 58--00 Capscrew 797-008 4 3 Lockwasher 950-003 4 Inner Sleeve 4 -/8 Bore 803-0069 -/4 Bore 803-0070 -3/8 Bore 803-007 5 Capscrew 797-0086 4 6 Lockwasher 950-003 4 7 Rotor Assembly 58-75-00 8 Ball Bearing 66-00 9 Retainer Ring 748-00 0 Retainer Ring 748-000 Rotor Adapter 58-05-00 EC-85 Item Description Part No. Qty. Roller Bearing 66-078 3 Oil Seal 795-006 4 Retainer Ring 748-004 5 Ball Bearing 66-004 6 Retainer Ring 748-0004 Field 7 6 volt 58-45-00 4 volt 58-45-004 90 volt 58-45-005 8 Set Collar 66-000 9 Conduit Box 500-0-0 0 Mounting Accessory with Keys 58-0-00 Refer to Service Manual P-0. These units when used with the correct Warner Electric conduit box, meets the standards of UL508 and are listed under guide care #NMTR, file #5964. These units are CSA Certified under file #LR543. Service Parts Warner Electric 800-34-3369 93

Electro Clutch EC-000, EC-5 EC Series -5 0 9 0 6 7 8 - - -3 5-4 9 3 4 0 6 7 8 5 4 3 Service Parts 94 Warner Electric 800-34-3369

EC Series Electro Clutch EC-000, EC-5 Component Parts EC-000 EC-5 Item Description Part No. Qty. Part No. Qty. Armature & Carrier Assembly 583--00 584--00 - Capscrew 797-63 6 797-63 8 - Lockwasher 950-0 6 950-0 8-3 Autogap Accessory 50-0-008 3 50-0-008 4-4 Hub 540-338 540-340 -5 Armature 530--03 5385--003 Inner Sleeve 3/8" Bore 803-007 -/" Bore 803-066 -5/8" Bore 803-008 -5/8" Bore 803-0078 -7/8" Bore 803-0030 -/8" Bore 803-003 3 Capscrew 797-0083 8 797-046 8 4 Lockwasher 950-003 8 950-006 8 5 Rotor Assembly 583-0-00 584-0-006 6 Ball Bearing 66-068 66-070 7 Retainer Ring 748-0067 748-0503 8 Outer Sleeve 803-005 803-003 9 Roller Bearing 66-080 66-08 0 Oil Seal 795-009 795-0033 Adapter Ring 748-0480 748-0466 Ball Bearing 66-063 66-063 3 Retainer Ring 748-050 748-050 4 Retainer Ring 748-04 748-04 Field 5 6 volt 583-45-00 584-45-00 4 volt 583-45-00 584-45-00 90 volt 583-45-003 584-45-003 6 Lockwasher 950-0355 6 950-0359 6 7 Capscrew 797-0083 6 797-046 6 8 Set Collar 66-005 66-006 9 Set Screw 797-0468 797-030 0 Terminal Accessory 53-0-00 53-0-00 Mounting Accessory with Keys -3/8" Bore 583-0-005 -/" Bore 583-0-009-5/8" Bore 583-0-006 584-0-007-7/8" Bore 584-0-00 -/8" Bore 584-0-00 Conduit Box 500-0-0 500-0-0 Refer to Service Manual P-0. These units when used with the correct Warner Electric conduit box, meets the standards of UL508 and are listed under guide care #NMTR, file #5964. These units are CSA Certified under file #LR543. Service Parts Warner Electric 800-34-3369 95

Electro Brake EB-375, EB-475, EB-650 EB Series -4-5 - - -3 4 9 0 8 5 3 5 6 7 3 3 Optional 4 Service Parts 96 Warner Electric 800-34-3369

EB Series Electro Brake EB-375, EB-475, EB-650 Component Parts EB-375 EB-475 EB-650 Item Description Part No. Qty. Part No. Qty. Part No. Qty. Armature & Carrier Assembly 5380-0-006 538-0-004 538-0-005 - Capscrew 797-4 3 797-4 4 797-0086 4 - Lockwasher 950-00 3 950-00 4 950-003 4-3 Autogap Accessory 580-0-0 3 58-0-00 4 58-0-00 4-4 Carrier 5380-95-00 538-95-003 538-95-00-5 Armature 580--00 58--00 58--00 *Bushing 80-040-80-048 80-04-80-0435 / to bore / to -3/8 bore Hub 540-054 540-053 3 /" Bore 540-050 5/8" Bore 540-059 Set Screw 4 /" Bore 797-0368 5/8" Bore 797-0366 5 Retainer Ring 748-00 748-00 748-004 6 Ball Bearing 66-050 66-00 66-004 7 Retainer Ring 748-008 748-000 748-0004 Magnet 8 6 volt 5380-63-003 538-63-003 538-63-003 4 volt 5380-63-004 538-63-004 538-63-005 90 volt 5380-63-00 538-63-00 538-63-00 9 Locknut 66-0050 66-005 66-0004 0 Washer 950-009 950-006 950-0030 Rod End Bearing 66-086 66-087 66-088 Torque Arm Rod Assembly 5380--00 538--00 538--00 3 Terminal Accessory 53-0-00 53-0-00 53-0-00 Adapter (optional) 5/8" Motor Shaft 5380-0-005 4 7/8" Motor Shaft 5380-0-004 -/8" Motor Shaft 538-0-003-3/8" Motor Shaft 538-0-003-5/8" Motor Shaft 538-0-00 5 Conduit Box 500-0-00 500-0-00 500-0-00 *See page 35 for specific part numbers. Refer to Service Manual P-. These units when used with the correct Warner Electric conduit box, meets the standards of UL508 and are listed under guide care #NMTR, file #5964. These units are CSA Certified under file #LR543. Service Parts Warner Electric 800-34-3369 97

EB-85 Electro Brake EB Series c b a 7 9 8 3 0 5 4 3 6 Service Parts 98 Warner Electric 800-34-3369

EB Series Electro Brake EB-85 Component Parts EB-85 Item Description Part No. Qty. Armature Assembly 5383--00 a Hub 540-99 b Autogap Assembly 50-0-008 3 c Armature 58--00 *Bushing 80-000 to 80-008 /" to -/" Bore 3 Ball Bearing 66-068 4 Retainer Ring 748-00 5 Retainer Ring 748-0584 6 Adapter Ring 748-063 EB-85 Item Description Part No. Qty. Magnet Assembly 7 6 volt 5383-63-00 4 volt 5383-63-004 90 volt 5383-63-005 8 Capscrew 797-0079 6 9 Lockwasher 950-037 6 0 Terminal Accessory 53-0-00 Conduit Box 500-0-0 Torque Arm Rod Assembly 538--00 3 Rod End Assembly 538-0-007 *See page 35 for specific part numbers. Refer to Service Manual P-. These units when used with the correct Warner Electric conduit box, meets the standards of UL508 and are listed under guide care #NMTR, file #5964. Service Parts Warner Electric 800-34-3369 99

Electro Brake EB-000, EB-5 EB Series -5 3-4 -3 - - 3-4 3-3 - 3 Optional -3-8 0 9 4 7 4 5 6 5 3-3- -4-3 - - -3-5 - Service Parts 00 Warner Electric 800-34-3369

EB Series Electro Brake EB-000, EB-5 Component Parts EB-000 EB-5 Item Description Part No. Qty. Part No. Qty. Armature & Carrier Assembly 5384--003 5385--004 - Capscrew 797-63 6 797-63 8 - Lockwasher 950-0 6 950-0 8-3 Autogap Accessory 50-0-008 3 50-0-008 4-4 Hub 540-339 540-34 -5 Armature 530--03 5385--003 *Bushing 80-03-80-049 80-085-80-07 /" to -5/8" bore /" to -/" bore 3 Hub 540-0579 540-0578 4 Ball Bearing 66-064 66-063 5 Retainer Ring 748-06 748-04 6 Retiner Ring 748-050 748-0074 7 Adapter Ring 748-0467 748-0465 Magnet Assembly 8 6 volt 5384-63-00 5385-63-00 4 volt 5384-63-009 5385-63-009 90 volt 5384-63-003 5385-63-003 9 Capscrew 797-046 6 797-046 6 0 Lockwasher 950-006 6 950-006 6 Terminal Accessory 53-0-00 53-0-00 Torque Arm Rod Assembly 5385-757-00 5385-757-00 - Ball Joint 585-000 585-000 - Jam Nut 66-00 3 66-00 3-3 Lockwasher 950-04 3 950-04 3-4 Threaded Rod 756-0030 756-0030 -5 Bracket 74-0073 74-0073 Torque Arm Mounting Accessory 5385-0-00 5385-0-00 3- Capscrew 797-093 797-093 3 3- Lockwasher 950-0354 950-0354 3-3 Jam Nut 66-00 66-00 3-4 Lockwasher 950-04 950-04 Adapter (optional) -5/8" Motor Shaft 5384-0-008 4-7/8" Motor Shaft 5384-0-007 -/8" Motor Shaft 5384-0-00 5385-0-008-3/8" Motor Shaft 5385-0-007 5 Conduit Box 500-0-0 500-0-0 *See page 35 for specific part numbers. Refer to Service Manual P-. These units when used with the correct Warner Electric conduit box, meets the standards of UL508 and are listed under guide care #NMTR, file #5964. These units are CSA Certified under file #LR543. Service Parts Warner Electric 800-34-3369 0

AT Clutch ATC-5, ATC-55, ATC-5 ATC Series 5 Optional 7-3 7-4 7-4 3 4 3 5 7-3 7-9 0 8-5 8-8- 8-3 8-4 6 Optional 8 6 7- Service Parts 0 Warner Electric 800-34-3369

ATC Series Component Parts AT Clutch ATC-5, ATC-55, ATC-5 ATC-5 ATC-55 ATC-5 Item Description Part No. Qty. Part No. Qty. Part No. Qty. Armature Hub 540-0907 540-085 540-0863 Retaining Ring 748-073 748-076 748-0737 3 Retaining Ring 748-073 748-078 748-0736 4 Bearing 66-078 66-077 66-079 5 Spacer 807-09 807-06 807-063 Splined Hub /" Bore 540-090 5/8" Bore 540-09 3/4" Bore 540-09 540-50 6 7/8" Bore 540-093 540-50 " Bore 540-503 -/8" Bore 540-504 540-0857 -/4" Bore 540-0858 -3/8" Bore 540-0859 -/" Bore 540-0860 *7- Armature 0-00 0-08 0-03 *7- Screw 797-59 4 797-46 6 797-463 6 *7-3 Lockwasher 950-0436 4 950-0355 6 950-0355 6 *7-4 Flatwasher 950-003 950-003 *8 Rotor 56-75-00 56-75-00 563-75-00 8- Facing Assembly 56-445-003 56-445-003 563-445-003 8- Retainer Plate 686-008 8-3 Detent Ring 748-03 748-038 748-00 8-4 Wave Spring 808-0404 808-040 808-0384 8-5 Machine Screw 797-389 8 797-389 8 797-389 8 *9 Bearing 66-083 66-084 66-079 Field Assembly 0 6 volts DC 56-45-00 56-45-00 563-45-00 90 volts DC 56-45-003 56-45-003 563-45-003 4 volts DC 56-45-004 56-45-004 563-45-004 * Retainer Ring 748-008 748-077 748-0737 Adapter 04-0300 3 Screw 797-396 4 4 Lockwasher 950-00 4 Optional Accessory Items 5 Conduit box 00-56-0-00 56-0-00 56-0-00 6 Restraining Arm Assembly 56-0-004 56-0-004 563-0-004 Kit Items * Clutch Rebuild Kit 56-0-0 56-0-0 563-0-0 (includes items 7-, 7-, 7-3, 7-4, 8, 9, ) Note: In some versions of this product, item 8 consists of a one () piece rotor. Friction Face Replacement Kit 56-0-007 56-0-007 563-0-007 For Clutches with Replaceable Friction Face Only Mounting Accessory Kits (not shown) / Bore - 3/4 Bore 56-0-00 - Ring Retainer Ext. 748-0734 - Wire Retainer 74-007 -3 Key 590-004 -4 Setscrew 797-393 7/8 Bore 56-0-00 - Ring Retainer Ext. 748-0734 - Wire Retainer 74-007 -3 Key 590-004 -4 Collar and Setscrew 66-003 3/4 Bore - Bore 56-0-00 - Ring Retainer Ext. 748-075 - Wire Retainer 74-006 -3 Key 590-003 -4 Setscrew 797-386 -/8 Bore 56-0-00 - Ring Retainer Ext. 748-075 - Wire Retainer 74-006 -3 Key 590-003 -4 Setscrew 797-077 -5 Collar 66-003 All bore sizes 563-0-00 - Ring Retainer Ext. 748-0738 - Wire Retainer 74-006 -3 Key 590-005 -4 Setscrew 797-395 Service Parts Warner Electric 800-34-3369 03

AT Brake ATB-5, ATB-55, ATB-5 ATB Series 6 (Optional) 7 (Optional) 7-7- 7-3 6 7-4 7-5 7-6 8 5 3 4 5 7-4 7-5 9 3 4 0 Electrical and Mechanical Data Model Voltage Resistance Current Coil Build Up Coil Decay Inertia* WR Max. Weight Size DC Unit (Ohms) (Amps) Watts (MMS) (MMS) (lb.ft. ) RPM lbs. 6.37 4.38 6.3 45 9.048 3600 8 5 4 Brake 0..9 8.6 45 9.048 3600 8 90 90.3 7.9 45 9.048 3600 8 6. 4.96 9.8 0 35.73 3600 8 55 4 Brake 9.6. 9.3 0 35.73 3600 8 90 30.39 35. 0 35.73 3600 8 6.0 5.9 35.4 50 45.483 3600 8 5 4 Brake 6.5.46 35 50 45.483 3600 8 90 8.50 44.6 50 45.483 3600 8 Service Parts 04 Warner Electric 800-34-3369

ATB Series AT Brake ATB-5, ATB-55, ATB-5 Component Parts ATB-5 ATB-55 ATB-5 Item Description Part No. Qty. Part No. Qty. Part No. Qty. Retainer 748-008 748-077 748-0737 Screw 797-03 3 797-03 4 797-03 4 3 Plate 686-066 686-06 686-07 4 Wave Spring 808-0404 808-040 808-0384 5 Detent Ring 748-03 748-038 748-00 6 Armature Hub 540-0908 540-085 540-0864 * 7- Armature 0-00 0-08 0-03 * 7- Facing Assembly 56-445-003 56-445-003 563-445-003 * 7-3 Screw 797-389 6 797-389 8 797-389 8 * 7-4 Screw 797-59 4 797-46 6 797-463 6 * 7-5 Lockwasher 950-0436 4 950-0355 4 950-0355 6 * 7-6 Flatwasher 950-003 950-003 Magnet Assembly 6 volts DC 59-63-00 59-63-00 593-63-00 8 4 volts DC 59-63-004 59-63-004 593-63-004 90 volts DC 59-63-003 59-63-003 593-63-003 9 Setscrew 797-393 797-386 797-395 Splined Hub /" Bore 540-090 5/8" Bore 540-090 3/4" Bore 540-0903 540-5 0 7/8" Bore 540-0904 540-53 " Bore 540-54 -/8" Bore 540-55 540-0866 -/4" Bore 540-0867 -3/8" Bore 540-0868 -/" Bore 540-0869 Ball Bearing 66-083 66-077 66-079 Retainer Ring 748-008 748-076 748-0737 3 Shim 80-035 80-034 80-036 4 Backplate 686-067 686-063 686-07 5 Screw 797-39 4 797-0437 3 797-0447 3 Optional Accessory Items 6 Conduit box 56-0-00 56-0-00 56-0-00 7 Torque Arm 59-0-00 59-0-00 593-0-00 Kit Items Friction Face Replacement Kit 56-0-007 56-0-007 563-0-007 *8 (includes items 7-, 7-, 7-3, 7-4, 7-5, 7-6) Brake Rebuild Kit 59-0-006 59-0-006 593-0-006 9 (includes items,,, 4, 5, 7-, 7-, 7-3, 7-4, 7-5, 7-6, 9,,, 5) Refer to Service Manual P-8. Service Parts Warner Electric 800-34-3369 05

Electro Pack EP-70, EP-50, EP-400 EP Series 9 0 3 3a 9 9a 6 3 5 6 6 7 7-8 8 3 5 4 7-5 6 9 9a 3 4 5 4 4 8 0 7 Service Parts 06 Warner Electric 800-34-3369

EP Series Electro Pack EP-70, EP-50, EP-400 Component Parts EP-70 EP-50 EP-400 Item Description Part No. Qty. Part No. Qty. Part No. Qty. Magnet Assembly 6 volt 5375-63-003 539-63-00 55-63-00 4 volt 5375-63-005 539-63-003 55-63-003 90 volt 5375-63-007 539-63-005 55-63-004 - Terminal Accessory 503-0-00 503-0-00 Armature Assembly with Autogap 0-0 530--008 53--00 3 Housing 535-0079 535-008 535-0083 4 Armature Spacer 807-0 5 Splined Armature Hub 540-50 540-635 540-034 6 Rotor Assembly 5603-75-09 503-75-00 504-75-034 Field Assembly 7 6 volt 5603-45-047 503-45-00 504-45-03 4 volt 5603-45-049 503-45-004 504-45-033 90 volt 5603-45-05 503-45-007 504-45-034 7- Terminal Accessory 503-0-00 503-0-00 8 Ball Bearing 66-0 66-04 66-06 9 Key 590-0095 590-004 9a Key 590-006 0 Shaft, Brake 798-036 798-033 798-03 Retainer Ring 748-0346 748-0347 748-0348 Retainer Ring 748-004 748-004 748-00 3 Key 590-0089 590-0088 590-0087 3a Key 590-006 4 Capscrew 797-9 8 797-9 8 797-0 8 5 Lockwasher 950-035 8 950-035 8 950-0355 8 6 Bearing Housing 535-0080 535-008 535-0084 7 Ball Bearing, with Retainer 66-0 66-03 66-05 8 Shaft, Clutch 798-035 798-034 798-03 9 Cover Plate 686-07 686-08 686-09 0 Screw 797-005 4 797-005 4 797-005 4 Dust Plug 680-0037 680-0037 680-0037 Gasket 495-0003 495-0004 495-0005 3 Insulator 57-0573 57-057 57-0574 4 Vertical Mfg. Spring Kit Optional 5603-0-00 503-0-006 504-0-005 5 Ground Screw 797-45 797-45 6 Terminal 900-06 900-006 Lead wires used on EP-70. These units meet the standards of UL508 and are listed under guide card #NMTR, file #5964. These units are CSA certified under file #LR543. Service Parts Warner Electric 800-34-3369 07

EP-500 Electro Pack EP Series 3 6-6 5-3 -4-5 - - - - - -3-4 -5 7 8 4 6 5 9 0 9 3 8 7 9 0 5 6 3 4 0 8 4 7 Component Parts Item Description Part No. Qty. Magnet Assembly 6 volt 5300-63-009 4 volt 5300-63-00 90 volt 5300-63-0 - Terminal Accessory 53-0-00 Armature Assembly 530--00 - Armature 530--00 - Retainer Ring 748-0355 -3 Spring 808-04 -4 Retainer Plate 748-0364 -5 Screw 797-008 3 Mounting Frame 74-008 4 Splined Hub 540-035 5 Rotor 530-75-00 Field 6 6 volt 530-45-003 4 volt 530-45-005 90 volt 530-45-00 Refer to Service Manual P-. These units meet the standards of UL508 and are listed under guide card #NMTR, file #5964. These units are CSA certified under file #LR543. Service Parts 08 Warner Electric 800-34-3369 Item Description Part No. Qty. 6- Terminal Accessory 53-0-00 7 Capscrew 797-046 8 8 Lockwasher 950-007 8 9 Ball Bearing 66-05 0 Key 590-000 Retainer Ring 748-036 Shaft, Brake 798-00 3 Key 590-00 4 Retainer Ring 748-0335 5 Capscrew 797-048 8 6 Lockwasher 950-007 8 7 Endbell Housing 535-000 8 Ball Bearing 66-07 9 Key 590-00 0 Shaft, Clutch 798-008 Cover Drip Proof 87-0068 Capscrew 797-4 6 3 Lockwasher 950-00 6

EP Series Electro Pack EP-85 7 8 6 5-4 5 5-4 5-3 5-6 6 7 8 9 0 - - -3-5 5-5-5 - -4 7 0 3 0 4 7 5 6 5 4 3 4 5 6 3 3 8 9 Component Parts Item Description Part No. Qty. Magnet Assembly 6 volt 53-63-00 4 volt 53-63-003 90 volt 53-63-004 Armature Assembly & Splined Adapter 53--00 - Screw 797-07 3 - Autogap Accessory 53-0-006-3 Splined Adapter 04-0008 -4 Armature 53--0-5 Locknut 66-0004 3 3 Frame 74-009 4 Splined Hub 540-030 5 Armature & Splined Adapter 50--00 5- Locknut 66-0004 3 5- Splined Adapter 04-0008 5-3 Autogap Accessory 53-0-006 5-4 Spacer 748-0333 3 5-5 Armature 53--0 5-6 Screw 797-034 3 6 Bushing, -/4" Bore 80-03 7 Rotor Hub 540-003 8 Rotor 50-75-003 Field 9 6 volt 50-45-006 4 volt 50-45-008 90 volt 50-45-00 Item Description Part No. Qty. 0 Mounting Accessory 50-0-007 Mounting Accessory 53-0-00 Screw 797-008 8 3 Oil Seal 795-003 4 Retainer Plate 686-003 5 Ball Bearing 66-06 6 Retainer Ring 748-0336 7 Key 590-009 3 8 Shaft, Brake 798-009 9 Retainer Ring 748-0335 0 Capscrew 797-035 8 Lockwasher 950-0354 8 Endbell Housing 535-0005 3 Ball Bearing 66-05 4 Key 590-008 5 Shaft, Clutch 798-000 6 Cover, Drip Proof 87-0069 7 Capscrew 797-4 6 8 Lockwasher 540-00 6 Refer to Service Manual P-. These units meet the standards of UL508 and are listed under guide card #NMTR, file #5964. These units are CSA certified under file #LR543. Warner Electric 800-34-3369 09

EP-000 Electro Pack EP Series 4 3 6 5 4 9 9-0 9-9-6 9-4 7 - -3 - -5 8 9-3 9-5 5 9 8-3 5 3 6 9 0-6 9 8 7-3 -4 0 39 5 6 8 30 7 4 7 Service Parts 0 Warner Electric 800-34-3369

EP Series Electro Pack EP-000 Component Parts Item Description Part No. Qty. Magnet Assembly 6 volt 53-63-004 4 volt 53-63-005 90 volt 53-63-006 - Wire Assembly 53-954-003 - Wire Assembly 53-954-004-3 Terminal Accessory 53-0-00 Armature & Splined Adapter 53--00 - Button Head Screw 797-07 - Autocap Accessory 53-0-004-3 Splined Arm, Adapter 04-0009 -4 Armature 53--036-5 Locknut 66-0004 3 3 Frame 74-0043 4 Dust Cover 87-005 5 Button Head Screw 797-75 8 6 Lockwasher 950-003 8 7 Splined Armature Hub 540-006 8 Bushing, -7/8" Bore 80-077 9 Armature & Splined Adapter 50--00 9- Locknut 66-0004 3 9- Splined Armature Adapter 04-0009 9-3 Autogap Accessory 53-0-004 9-4 Spacer 748-0333 3 Item Description Part No. Qty. 9-6 Cap Screw 797-034 3 0 Bushing, " Bore 80-079 Rotor Hub 540-035 Rotor 50-75-003 Field Assembly 3 6 volt 50-45-004 4 volt 50-45-006 90 volt 50-45-007 4 Mounting Accessory 53-0-00 5 Mounting Accessory 50-0-007 6 Mounting Accessory 53-0-00 7 Oil Seal 795-004 8 Button Head Screw 797-008 8 9 Retainer Plate 686-0047 0 Retainer Ring External 748-0504 Ball Bearing 66-030 Retainer Ring Internal 748-0375 3 Key 590-004 4 Shaft, Brake 798-006 5 Cap Screw 797-036 8 6 Lockwasher 950-036 8 7 Bearing Housing 535-00 8 Ball Bearing 66-03 9 Key 590-005 9-5 Armature 53--036 30 Shaft, Clutch 798-005 Refer to Service Manual P-. These units meet the standards of UL508 and are listed under guide card #NMTR, file #5964. These units are CSA certified under file #LR543. Service Parts Warner Electric 800-34-3369

Electro Pack EP-55, EP-55HT EP Series 3 7 4 4 6 5 0-0- 0 0-6 0-7 9 8 - -3 - -6 9 0-4 0-3 0-5 5 9 7-3 6 7 4 0-4 -5 - -3 6 3 9 0 8 7 4 6 7 9 5 3 8 5 8 Service Parts Warner Electric 800-34-3369

EP Series Electro Pack EP-55, EP-55HT Component Parts Service Parts EP-55 EP-55HT Item Description Part No. Qty. Part No. Qty. Magnet 6 volt 534-63-004 4 volt 534-63-006 90 volt 534-63-005 534-63-005 *- Wire Assembly 53-954-003 53-954-003 *- Wire Assembly 53-954-004 53-954-004 *-3 Terminal Accessory 53-0-00 53-0-00 Armature & Splined Adapter 534--00 534--00 *- Button Head Screw 797-07 8 797-07 8 *- Armature Plate 686-0003 686-0003 *-3 Autogap Accessory 533-0-00 533-0-00 *-4 Splined Armature Adapter 04-00 04-00 *-5 Armature 534--034 534--034 *-6 Locknut 66-0004 8 66-0004 8 3 Frame 74-0044 74-0044 4 Dust Cover 87-0040 87-00 5 Button Head Screw 797-75 8 797-75 8 6 Lock Washer 950-003 8 950-003 8 7 Eye Bolts 7-0006 4 7-0006 4 8 Splined Armature Hub 540-0063 540-0063 9 Bushing, -3/8" Bore 80-05 80-05 0 Armature & Splined Adatper 504--004 504--004 *0- Cap Screw 797-034 8 797-034 8 *0- Splined Armature Adapter 04-00 04-00 *0-3 Autogap Accessory 533-0-00 533-0-00 *0-4 Retainer Plate 686-0003 686-0003 *0-5 Armature 534--034 534--034 *0-6 Spacer 748-0333 8 748-0333 8 *0-7 Locknut 66-0004 8 66-0004 8 Rotor Hub 534-54-00 534-54-00 Rotor 504-75-00 504-75-00 Field Assembly 3 6 volt 504-45-03 4 volt 504-45-066 90 volt 504-45-06 504-45-006 4 Mounting Accessory 53-0-00 53-0-00 5 Mounting Accessory 53-0-00 53-0-00 6 Mounting Accessory 53-0-00 53-0-00 7 Screw 797-094 8 797-094 8 8 Oil Seal 795-005 795-005 9 Retainer Plate 686-0048 686-0048 0 Retaining Ring External 748-0503 748-0503 Ball Bearing 66-03 66-03 Bearing Seal 795-0036 795-0036 3 Retainer Ring Internal 748-055 748-005 4 Key 590-008 590-008 5 Shaft 798-007 798-007 6 Cap Screw 797-036 797-036 7 Lock Washer 950-036 950-036 8 Bearing Housing 535-003 535-003 9 Ball Bearing 66-033 66-033 * Shipped Assembled Refer to Service Manual P-. These units meet the standards of UL508 and are listed under guide card #NMTR, file #5964. These units are CSA certified under file #LR543. Warner Electric 800-34-3369 3

Electrically Released Brakes FB-375, FB-475, FB-650 Permanent Magnet 6 9 3 4 5 8 7 Service Parts 4 Warner Electric 800-34-3369

FB Series Electrically Released Brakes FB-375, FB-475, FB-650 FB-375 FB-475 FB-650 Item Description Part Number Qty Part Number Qty Part Number Qty Optional Parts *Bushing N/A 80-040 /" bore 80-04 /" bore to 80-048 " bore to 80-0435 -3/8" bore Adapter (optional) 5/8" motor shaft 5380-0-005 7/8" motor shaft 5380-0-004 -/8" motor shaft 538-0-003-3/8" motor shaft 538-0-003-5/8" motor shaft 538-0-00 Service Parts 3 Retainer ring 748-00 748-00 748-004 4 Ball bearing 66-050 66-00 66-004 5 Retainer ring 748-008 748-000 748-0004 6 Torque arm mount assembly 5380-0-007 538-0-006 538-0-007 7 Torque arm rod assembly 5380--00 538--00 538--00 8 Terminal accessory 53-0-00 53-0-00 53-0-00 9 Conduit Box 500-0-00 500-0-00 500-0-00 *See page 35 for specific part numbers. These units, when used with the correct Warner Electric conduit box, meet the standards of UL508 and are listed under guide card #NMTR, file #5964 and are CSA certified under file #LR543. Magnet and armature are not field replaceable. Service Parts Warner Electric 800-34-3369 5

Electrically Released Brakes ER-375, ER-475, ER-650 ER Series 3A, 3B 3A-, 3B- 5 5 3A- 3B- 4 3B 4 3A Inside Mounted Outside Mounted Component Parts ER-375 ER-475 ER-650 Item Description Part Number Qty Part Number Qty Part Number Qty Bushing 80-040-048 80-04-0435 (/" to " Bore) (/" to -3/8" Bore) Hub 540-0849 540-0848 /" Bore 540-0846 5/8" Bore 540-0847 3A Magnet and Armature (Inside Mounted, 90 Volt) Sold only in matched pairs* 555-5 556-6 3A- Autogap Accessory 539-0-003 4 539-0-003 4 3A- Terminal Accessory 503-0-00 503-0-00 3B Magnet and Armature (Outside Mounted, 90 Volt) Sold only in matched pairs* 554-555-6 556-7 3B- Autogap Accessory 5390-0-00 3 539-0-003 4 539-0-003 3B- Terminal Accessory 503-0-00 503-0-00 503-0-00 Mounting Accessory 4 Inside Mount 555-0-00 556-0-003 Outside Mount 554-0-00 555-0-00 556-0-003 5 Conduit Box 500-0-00 500-0-00 500-0-00 See page 35 for specific part numbers. * Magnets and armatures sold only in pre-burnished sets to assure rated torque available upon installation. These units, when used with the correct Warner Electric conduit box, meet the standards of UL508 and are listed under guide card #NMTR, file #5964 and are CSA certified under file #LR543. Service Parts 6 Warner Electric 800-34-3369

ER Series Electrically Released Brakes ER-85, ER-5 7 9 4 3 5 6-6 Heavy Duty 7 Normal Duty 8 Component Parts ER-85 ER-85 ER-5 ER-5 Normal Duty Heavy Duty Normal Duty Heavy Duty Item Description Part Number Qty. Part Number Qty. Part Number Qty. Part Number Qty. Bushing 80-037-80-049 80-0008-80-008 80-06-80-095 80-006-80-0057 7/8" to-5/8" Bore 7/8" to -/" Bore 5/6" to 3" Bore 3/4" to -/6" Bore Armature Hub 540-0394 540-005 3 Splined Hub 540-0057 540-0064 4 Retainer Ring 748-0006 748-0005 5 Mounting Accessory, I.M. 53-0-00 53-0-00 53-0-00 53-0-00 6 & 7 Magnet (I.M., 90 volt) and Armature sold only in matched pairs* 550-30 550-5 55-9 55-4 6- Terminal Accessory 53-0-00 53-0-00 53-0-00 53-0-00 8 Autogap Accessory 50-0-008 3 50-0-008 4 9 Conduit Box 500-0-00 500-0-00 500-0-00 500-0-00 See page 35 for specific part numbers. * Magnets and armatures sold only in pre-burnished sets to assure rated torque available upon installation. These units, when used with the correct Warner Electric conduit box, meet the standards of UL508 and are listed under guide card #NMTR, file #5964 and are CSA certified under file #LR543. Service Parts Warner Electric 800-34-3369 7

Electrically Released Brakes UM-00 FBC Motor Clutch/Electrically Released Brake UM-FBC Series - 6 5-5 7 3 4 6 6 5 5-3 5-4 9 8 3 0 4a 5 4b 7 5-4 5-3 0 9 8 Service Parts 8 Warner Electric 800-34-3369

UM-FBC Series Electrically Released Brakes UM-00 FBC Motor Clutch/Electrically Released Brake Component Parts UM-50 UM-00 UM-80 UM-0 UM-5 Item Description Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty Rotor Assembly w/fan and hub 5370-75-09 5370-75-0 5370-75-07 537-75-0 537-75-03 - Setscrew 797-098 797-0069 797-0069 797-098 798-098 Field w/housing 4 volt 5370-45-064 5370-45-059 537-45-09 90 volt 5370-45-063 5370-45-058 5370-45-058 537-45-08 537-45-08 3 Capscrew 797-45 797-45 797-45 797-45 797-45 4 Lockwasher 950-0436 4 950-00 950-0436 5 950-037 950-00 5 Retaining Ring 748-00 748-00 748-00 748-0558 748-0558 6 Ball Bearing 66-050 66-00 66-00 66-068 66-068 7 Retaining Ring 748-008 748-00 748-000 748-0067 8 Armature 5370--0 5370--03 5370--03 537--005 537--005 Magnet and Armature (sold only in 9 matched pairs)* 4 volt 5370-6 5370-8 537-3 90 volt 5370-5370- 5370-537- 537-0 Armature Hub 540-640 540-644 540-644 540-0835 540-040 Retaining Ring 748-0445 748-0676 748-0676 Capscrew 797-008 6 797-008 6 3 Lockwasher 950-037 6 950-037 6 4a Retaining Ring 748-03 748-00 748-00 748-0 748-0 4b Retaining Ring 748-03 5 Ball Bearing 66-049 66-00 66-00 66-04 66-04 6 Spacer 807-085 807-085 807-085 807-053 807-053 7 Housing 535-070 535-07 535-07 535-07 535-07 8 Setscrew 797-047 4 797-047 4 797-047 4 797-047 4 797-047 9 Shaft 798-0046 798-08 798-0085 798-005 798-054 0 Key 590-009 590-009 590-009 590-009 590-04 Ball Bearing 66-055 66-043 66-043 66-044 66-044 Key 590-0043 590-0084 590-0084 3 Capscrew 797-94 797-94 797-0083 4 797-0083 4 4 Lockwasher 950-037 4 950-037 4 Mounting Accessory 5370-0-043 5370-0-043 5370-0-043 537-0-039 537-0-039 5- capscrew 797-440 4 797-440 4 797-440 4 797-453 4 5 5- lockwasher 950-0354 4 950-0354 4 950-0354 4 950-0 4 5-3 capscrew 797-44 4 5-4 lockwasher 950-00 4 5-5 adapter 04-03 6 Conduit Box (Optional) 5370-0-04 5370-0-04 5370-0-04 5370-0-04 Key for rotary assembly-not shown 5370-0-07 5370-0-07 5370-0-07 537-0-043 Refer to Service Manual P-3. *Magnets and armatures sold only in pre-burnished sets to assure maximum torque is available upon installation. Service Parts Warner Electric 800-34-3369 9

Electrically Released Brakes UM-030FBC Input Clutch/Electrically Released Brake UM-FBC Series 3 34 5 0 9 8 7 6 4 4 3 3 6 5 8 0 9 a b 33 3 7 4 3 30 7 9 6 8 5 Service Parts 0 Warner Electric 800-34-3369

UM-FBC Series Electrically Released Brakes UM-030FBC Input Clutch/Electrically Released Brake Component Parts UM-50 UM-80 UM-0 Item Description Part No. Qty. Part No. Qty. Part No. Qty. Rotor Assembly w/fan 5370-75-006 5370-75-009 537-75-007 Capscrew 797-94 4 797-4 5 797-0083 6 3 Lockwasher 950-0436 4 950-0436 5 950-037 6 4 Spacer 807-006 807-006 Field (with housing UM-50-0FBC only) 5 4 volt 5370-45-074 5370-45-005 537-45-005 90 volt 5370-45-073 5370-45-008 537-45-003 6 Retaining Ring 748-03 748-00 748-0 7 Ball Bearing 66-049 66-00 66-04 8 Retaining Ring 748-03 9 Retaining Ring 748-007 0 Housing 535-064 535-09 Setscrew 797-047 4 797-047 4 Shaft 798-0047 798-04 798-03 3 Bearing 66-055 66-043 66-044 4 Key 590-009 590-009 590-009 5 Armature Assembly 5370--0 5370--03 537--005 Magnet and Armature (sold only in pairs)* 6 4 volt 5370-6 5370-8 537-3 90 volt 5370-5370- 537-7 Armature Hub 540-640 540-644 540-0835 8 Retaining Ring 748-0445 748-0676 9 Capscrew 797-008 6 0 Lockwasher 950-037 6 a Retaining Ring 748-03 748-00 748-0 b Retaining Ring 748-03 Ball Bearing 66-049 66-00 66-04 3 Spacer 807-085 807-085 807-053 4 Housing 535-070 535-07 535-07 5 Setscrew 797-047 4 797-047 4 797-047 4 6 Shaft 798-0046 798-0085 798-005 7 Key 590-009 590-009 590-009 8 Ball Bearing 66-055 66-043 66-044 9 Key 590-0043 590-0084 30 Capscrew 797-94 797-0083 4 3 Lockwasher 950-037 4 3 Capscrew 797-0346 4 797-0346 4 797-357 4 33 Lockwasher 950-0354 4 950-0354 4 950-0033 4 34 Conduit Box (Optional) 5370-0-04 5370-0-04 5370-0-04 Refer to Service Manual P-3. *Magnets and armatures sold only in pre-burnished sets to assure maximum torque is available upon installation. Service Parts Warner Electric 800-34-3369

Electrically Released Brakes EM-0FBB Brake Module EM-FBB Series 3 4 8 7 6 5 4 3 7 5 7 6 9 0 Component Parts EM-50 EM-00 EM-80 EM-0 Item Description Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty. Magnet and Armature & (sold only in matched pairs)* 4 volt 5370-6 5370-8 5370-8 537-3 90 volt 5370-5370- 5370-537- 3 Armature Hub 540-638 540-677 540-64 540-074 4 Retaining Ring 758-0445 748-0676 748-0676 748-0 5 Lockwasher 950-037 6 6 Capscrew 797-008 6 7 Retaining Ring 748-03 748-00 748-00 8 Bearing 66-049 66-00 66-00 66-04 9 Housing 535-030 535-048 535-048 535-044 0 Setscrew 797-047 4 797-047 4 797-047 4 797-047 4 Shaft 5370-798-00 5370-798-005 5370-798-00 537-798-00 Key 590-009 590-009 590-009 590-009 3 Bearing 66-055 66-043 66-043 66-044 4 Mounting Accessory 5370-0-07 5370-0-07 5370-0-07 537-0-007 5 Key 590-0043 590-0084 590-0084 6 Capscrew 797-4 797-4 797-0083 7 Lockwasher 950-037 Refer to Service Manual P-3. *Magnets and armatures sold only in pre-burnished sets to assure maximum torque is available upon installation. Service Parts Warner Electric 800-34-3369

EM-MBFB Series Electrically Released Brakes EM-0 MBFB Motor Brake Module 5 6 3 7 6 4 0 8 3 4 5 7 9 Component Parts EM-50 EM-00 EM-80 EM-0 Item Description Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty. Magnet and Armature & (sold only in matched pairs)* 4 volt 5370-6 5370-8 5370-8 537-3 90 volt 5370-5370- 5370-537- 3 Capscrew 797-008 6 4 Lockwasher 950-037 6 5 Retaining Ring 748-0445 6 Key 590-0043 590-0084 590-0084 7 Splined Hub 540-638 540-677 540-64 540-074 8 Hub 5370-54-00 5370-54-004 5370-54-003 537-54-00 9 Retaining Ring 748-003 748-00 748-00 748-0 0 Retaining Ring 748-0676 748-0676 Bearing 66-049 66-00 66-00 66-4 Housing 535-036 535-050 535-050 535-049 3 Plug 680-008 680-008 680-008 680-007 4 Setscrew 797-047 4 797-047 4 797-047 4 797-047 4 5 Mounting Accessory 5370-0-07 5370-0-07 5370-0-03 537-0-007 6 Magnet mounting Screw 797-4 797-4 797-0083 7 Lockwasher 950-037 Refer to Service Manual P-3. *Magnets and armatures sold only in pre-burnished sets to assure maximum torque is available upon installation. Service Parts Warner Electric 800-34-3369 3

Electrically Released Brakes EM-0FBC Clutch/Brake Module EM-FBC Series 9 6 5 4 3 7 3 5 4 6 5 8 7 0 Component Parts 4 Warner Electric 800-34-3369 EM-50 EM-80 EM-0 Item Description Part No. Qty. Part No. Qty. Part No. Qty. Magnet and Armature & (sold only in matched pairs)* 4 volt 5370-6 5370-8 537-3 90 volt 5370-5370- 537-3 Armature Hub 540-640 540-644 540-0835 4 Retaining Ring 758-0445 748-0676 748-0 5 Lockwasher 950-037 6 6 Capscrew 797-008 6 7 Retaining Ring 748-03 748-00 8 Bearing 66-049 66-00 66-04 9 Armature 5370--0 5370--03 537--005 0 Housing 535-030 535-045 535-044 Setscrew 797-047 4 797-047 4 797-047 4 Shaft 798-0045 798-0086 798-0050 3 Key 590-009 590-009 590-009 4 Bearing 66-055 66-043 66-044 5 Mounting Accessory 5370-0-033 5370-0-034 537-0-08 6 Key 590-0043 590-0084 7 Capscrew 797-4 797-0083 8 Lockwasher 950-037 Refer to Service Manual P-3. *Magnets and armatures sold only in pre-burnished sets to assure maximum torque is available upon installation. Service Parts

Part Numbers Electro Modules - EM Description Model Part No. Voltage Pg. No. Motor Clutch 5370-70-00 6 Module EM-50-0 5370-70-030 4 3 5370-70-05 90 5370-70-045 6 EM-00-0 5370-70-056 4 3 5370-70-046 90 5370-70-0 6 EM-80-0 5370-70-055 4 3 5370-70-07 90 537-70-0 6 EM-0-0 537-70-07 4 3 537-70-009 90 Brake Module 5370-69-043 6 EM-50-0 5370-69-045 4 3 5370-69-04 90 5370-69-040 6 EM-00-0 5370-69-07 4 3 5370-69-04 90 5370-69-050 6 EM-80-0 5370-69-07 4 3 5370-69-05 90 537-69-0 6 EM-0-0 537-69-034 4 3 537-69-03 90 EM-5-0 537-69-076 90 3 Motor Brake 5370-69-047 6 EM-50-0MB 5370-69-06 4 3 5370-69-048 90 5370-69-053 6 EM-80-0MB 5370-69-073 4 3 5370-69-054 90 537-69-05 6 EM-0-0MB 537-69-035 4 3 537-69-06 90 Input Clutch 5370-70-09 6 Module EM-50-30 5370-70-05 4 3 5370-70-06 90 5370-70-047 6 EM-00-30 5370-70-054 4 3 5370-70-048 90 5370-70-049 6 EM-80-30 5370-70-053 4 3 5370-70-050 90 537-70-03 6 EM-0-30 537-70-06 4 3 537-70-04 90 Output Clutch EM-50-40 5370-536-008 3 Module EM-00-40 5370-536-007 3 EM-80-40 5370-536-009 3 EM-0-40 537-536-005 3 UniModules - UM Ordering Information C-face Compatible Units Description Model Part No. Voltage Pg. No. Clutch/Brake 5370-73-06 6 UniModule UM-50-00 5370-73-08 4 7 Fully Assembled 5370-73-07 90 Brake/Clutch Unit 5370-73-0 6 UM-50-030 5370-37-03 4 7 5370-73-0 90 5370-73-06 6 UM-00-00 5370-73-08 4 7 5370-73-07 90 5370-73-03 6 UM-00-030 5370-73-033 4 7 5370-73-03 90 5370-73-006 6 UM-80-00 5370-73-008 4 7 5370-73-007 90 5370-73-0 6 UM-80-030 5370-73-03 4 7 5370-73-0 90 537-73-00 6 UM-0-00 537-73-004 4 7 537-73-003 90 537-73-007 6 UM-0-030 537-73-009 4 7 537-73-008 90 537-73-076 6 UM-5-00 537-73-077 4 7 537-73-078 90 537-73-043 6 UM-5-030 537-73-044 4 7 537-73-045 90 Clutch 5370-7-004 6 UniModule UM-50-040 5370-7-006 4 7 Fully Assembled 5370-7-005 90 Clutch Unit 5370-7-009 6 UM-50-3040 5370-7-0 4 7 5370-7-00 90 5370-7-04 6 UM-00-040 5370-7-06 4 7 5370-7-05 90 5370-7-09 6 UM-00-3040 5370-7-03 4 7 5370-7-030 90 5370-7-04 6 UM-80-040 5370-7-06 4 7 5370-7-05 90 5370-7-09 6 UM-80-3040 5370-7-0 4 7 5370-7-00 90 537-7-00 6 UM-0-040 537-7-004 4 7 537-7-003 90 537-7-007 6 UM-0-3040 537-7-009 4 7 537-7-008 90 537-7-06 6 UM-5-040 537-7-07 4 7 537-7-08 90 537-7-0 6 UM-5-3040 537-7-0 4 7 537-7-03 90 UM 00 with UM-50-00 5370-9 Pre-Installed UM-00-00 5370-0 Controls UM-80-00 5370-73- 7 (CBC 50-) UM-0-00 537-4 UM-5-00 537-73-090 Warner Electric 800-34-3369 5

Ordering Information C-face Compatible Units UniModules Ceramic Faced UM-C Description Model Part No. Voltage Pg. No. C-face Mount 5370-73-077 6 UM-50-00-C 5370-73-078 4 37 5370-73-079 90 5370-73-073 6 UM-80-00-C 5370-73-074 4 37 5370-73-075 90 537-73-035 6 UM-0-00-C 537-73-036 4 37 537-73-037 90 Base/Foot Mount 5370-73-085 6 UM-50-030-C 5370-73-086 4 37 5370-73-087 90 5370-73-08 6 UM-80-030-C 5370-73-08 4 37 5370-73-083 90 537-73-039 6 UM-0-030-C 537-73-040 4 37 537-73-04 90 Enclosed UniModules EUM Description Model Part No. Voltage Pg. No. C-face Mount 5370-73-058 6 EUM-50-00 5370-73-059 4 46 5370-73-057 90 EUM-50-040 5370-7-050 90 46 5370-73-09 6 EUM-00-00 5370-73-093 4 46 5370-73-09 90 5370-73-066 6 EUM-80-00 5370-73-067 4 46 5370-73-065 90 EUM-80-040 5370-7-05 90 46 537-73-08 6 EUM-0-00 537-73-09 4 46 537-73-07 90 EUM-0-040 537-7-04 90 46 537-73-08 6 EUM-5-00 537-73-083 4 46 537-73-084 90 Base/Foot Mount 5370-73-06 6 EUM-50-030 5370-73-063 4 46 5370-73-06 90 5370-73-070 6 EUM-80-030 5370-73-07 4 46 5370-73-069 90 537-73-03 6 EUM-0-030 537-73-033 4 46 537-73-03 90 Accessories for EM, UM, UM-C and EUM Description Model Part No. Voltage Pg. No. Conduit Box All Sizes 5370-0-04 3 Controls CBC-50-6004-448-00 0 VAC 37, 8 CBC-50-6004-448-00 0 VAC 37, 8 Base Mount EM/UM-50/00 5370-0-004 7, 37 Kits EM/UM-80 5370-0-00 7, 37, 50 for 030 and 3040 EUM-50/00/80 5370-0-0 4 EM/EUM/UM-0 EM/EUM/UM-5 537-0-00 7, 37 Motor Mount EM/UM-50/00 5370-0-00 7 Kits EM/UM-80 for 0, 00, 040 EUM-50/00/80 5370-0-0 7 EM/EUM/UM-0 537-0-0 7 EM/EUM/UM-5 Fan Kits for 00 EUM-50/00 UM-50-C EUM-80 UM-80-C EUM-0 UM-0-C Enclosed UniModules Washdown Models EUM-W Part Numbers 5370-0-055 37, 46 5370-0-054 37, 46 537-0-09 37, 46 Description Model Part No. Voltage Pg. No. C-face Mount 5370-73-00 6 EUM-50-00W 5370-73-0 4 46 5370-73-099 90 5370-73-08 6 EUM-00-00W 5370-73-09 4 46 5370-73-07 90 5370-73-6 6 EUM-80-00W 5370-73-7 4 46 5370-73-5 90 537-73-056 6 EUM-0-00W 537-73-057 4 46 537-73-055 90 537-73-086 6 EUM-5-00W 537-73-087 4 46 537-73-088 90 Base/Foot Mount 5370-73-04 6 EUM-50-030W 5370-73-05 4 46 5370-73-03 90 5370-73-0 6 EUM-80-030W 5370-73- 4 46 5370-73-9 90 537-73-060 6 EUM-0-030W 537-73-06 4 46 537-73-059 90 Accessories for EUM-W ConduitBox All Sizes 5370-0-047 46 Controls CBC-50-6004-448-00 0 VAC 46 All Sizes CBC-50-6004-448-00 0 VAC 46 Base EUM-50W/80W 5370-0-047 46 Mount EUM-0W 537-0-05 46 Motor EUM-50W Mount EUM-00W 5370-0-049 46 EUM-80W EUM-0W EUM-5W 537-0-06 46 Fan Kits EUM-50W/00W 5370-0-060 46 EUM-80W 5370-0-06 46 EUM-0W 537-0-033 46 6 Warner Electric 800-34-3369

Part Numbers Electro Clutches - EC Description Model Part No. Voltage Pg. No. EC-375 580-7-006 6 EC-375-/ 580-7-004 4 53 580-7-009 90 580-7-00 6 EC-375-5/8 580-7-008 4 53 580-7-005 90 EC-475 58-7-004 6 EC-475-5/8 58-7-008 4 53 58-7-007 90 58-7-003 6 EC-475-3/4 58-7-009 4 53 58-7-005 90 58-7-00 6 EC-475-7/8 58-7-00 4 53 58-7-006 90 EC-650 58-7-004 6 EC-650-58-7-08 4 53 58-7-007 90 58-7-00 6 EC-650--/8 58-7-09 4 53 58-7-005 90 58-7-009 6 EC-650--/4 58-7-00 4 53 58-7-008 90 58-7-003 6 EC-650--3/8 58-7-06 4 53 58-7-006 90 EC-85 58-7-00 6 EC-85--/8 58-7-008 4 53 58-7-0 90 58-7-003 6 EC-85--/4 58-7-009 4 53 58-7-0 90 58-7-004 6 EC-85--3/8 58-7-00 4 53 58-7-03 90 EC-000 583-7-00 6 EC-000--3/8 583-7-00 4 53 583-7-003 90 EC-000--/ 583-7-0 4 583-7-03 90 53 583-7-004 6 EC-000--5/8 583-7-0 4 53 583-7-005 90 EC-5 584-7-008 6 EC-5--5/8 584-7-03 4 53 584-7-00 90 584-7-00 6 EC-5--7/8 584-7-04 4 53 584-7-003 90 584-7-004 6 EC-5--/8 584-7-05 4 53 584-7-005 90 Electro Brakes - EB Adapters for Electro Brakes Ordering Information Shaft Mounted Units Description Model Part No. Voltage Pg. No. EB-375 5380-70-005 6 EB-375-/ 5380-70-006 4 59 5380-70-004 90 5380-70-003 6 EB-375-5/8 5380-70-007 4 59 5380-70-00 90 EB-475 538-70-003 6 EB-475 538-70-004 4 59 538-70-00 90 EB-650 538-70-003 6 EB-650 538-70-005 4 59 538-70-00 90 EB-85 5383-70-00 6 EB-85 5383-70-004 4 59 5383-70-005 90 EB-000 5384-70-003 6 EB-000 5384-70-005 4 59 5384-70-00 90 EB-5 5385-70-003 6 EB-5 5385-70-005 4 59 5385-70-00 90 Adapter No. Part Number Pg. No. 375-3/8 5380-0-005 08 375-7/8 5380-0-004 08 475--/8 538-0-003 08 650--3/8 538-0-003 08 650--5/8 538-0-00 08 000--5/8 5384-0-008 60 000--7/8 5384-0-007 60 000--/8 5384-0-00 60 5--/8 5385-0-008 60 5--3/8 5383-0-007 60 Bushings for Electro Brakes Bushing No. Part Number Pg. No. 008 30 H-, H- 65 57 Specify Bore Size 80-040 to 80-048 Specify Bore Size 80-04 to 80-0435 Specify Bore Size 80-000 to 80-008 Specify Bore Size 80-03 to 80-049 Specify Bore Size 80-085 to 80-07 Warner Electric 800-34-3369 7

Ordering Information Shaft Mounted Units AT Clutches - ATC Description Model Part No. Voltage Pg. No. ATC-5 56-7-00 6 ATC-5-/ 56-7-00 4 69 56-7-003 90 56-7-004 6 ATC-5-5/8 56-7-0 4 69 56-7-005 90 56-7-006 6 ATC-5-3/4 56-7-0 4 69 56-7-007 90 56-7-008 6 ATC-5-7/8 56-7-03 4 69 56-7-009 90 ATC-55 56-7-00 6 ATC-55-3/4 56-7-00 4 69 56-7-003 90 56-7-004 6 ATC-55-7/8 56-7-0 4 69 56-7-005 90 56-7-006 6 ATC-55-56-7-0 4 69 56-7-007 90 56-7-008 6 ATC-55--/8 56-7-03 4 69 56-7-009 90 ATC-5 563-7-00 6 ATC-5--/8 563-7-00 4 69 563-7-003 90 563-7-004 6 ATC-5--/4 563-7-0 4 69 563-7-005 90 563-7-006 6 ATC-5--3/8 563-7-0 4 69 563-7-007 90 563-7-008 6 ATC-5--/ 563-7-03 4 69 563-7-009 90 AT Brakes - ATB Part Numbers Description Model Part No. Voltage Pg. No. ATB-5 59-70-00 6 ATB-5-/ 59-70-00 4 7 59-70-003 90 59-70-004 6 ATB-5-5/8 59-70-0 4 7 59-70-005 90 59-70-006 6 ATB-5-3/4 59-70-0 4 7 59-70-007 90 59-70-008 6 ATB-5-7/8 59-70-03 4 7 59-70-009 90 ATB-55 59-70-00 6 ATB-55-3/4 59-70-00 4 7 59-70-003 90 59-70-004 6 ATB-55-7/8 59-70-0 4 7 59-70-005 90 59-70-006 6 ATB-55-59-70-0 4 7 59-70-007 90 59-70-008 6 ATB-55--/8 59-70-03 4 7 59-70-009 90 ATB-5 593-70-00 6 ATB-5--/8 593-70-00 4 7 593-70-003 90 593-70-004 6 ATB-5--/4 593-70-0 4 7 593-70-005 90 593-70-006 6 ATB-5--3/8 593-70-0 4 7 593-70-007 90 593-70-008 6 ATB-5--/ 593-70-03 4 7 593-70-009 90 Stationary Field Clutches - SFP Description Model Part No. Voltage Pg. No. SFP-50 503-7-00 6 SFP-50-3/8 503-7-006 4 75 503-7-00 90 503-7-003 6 SFP-50-7/6 503-7-007 4 75 503-7-0 90 503-7-004 6 SFP-50-/ 503-7-009 4 75 503-7-0 90 503-7-005 6 SFP-50-5/8 503-7-008 4 75 503-7-03 90 Description Model Part No. Voltage Pg. No. SFP-400 504-7-006 6 SFP-400-/ 504-7-06 4 75 504-7-0 90 504-7-007 6 SFP-400-5/8 504-7-07 4 75 504-7-0 90 504-7-008 6 SFP-400-3/4 504-7-08 4 75 504-7-03 90 504-7-009 6 SFP-400-7/8 504-7-09 4 75 504-7-04 90 504-7-00 6 SFP-400-504-7-00 4 75 504-7-05 90 8 Warner Electric 800-34-3369

Part Numbers Base Mounted Units Electro Pack - EP Model Part No. Voltage Pg. No. 5633-73-00 6 EP-70 5633-73-003 4 77 5633-73-005 90 530-73-03 6 EP-50 530-73-03 4 77 530-73-034 90 53-73-009 6 EP-400 53-73-00 4 77 53-73-0 90 530-73-003 6 EP-500 530-73-0 4 77 530-73-00 90 53-73-003 6 EP-85 53-73-004 4 77 53-73-00 90 53-73-003 6 EP-000 53-73-005 4 77 53-73-00 90 EP-55 534-73-003 6 534-73-00 90 77 EP-55HT 534-73-07 4 534-73-0 90 Electro Pack Ceramic Faced - EP-C Model Part No. Voltage Pg. No. EP-70-C EP-50-C 5633-73-08 4 5633-73-09 90 530-73-053 4 530-73-054 90 Spring-Set Brakes (Static Holding) - ERS Description Model Part No. Voltage Pg. No. ERS ERS-6 ERS-4 ERS-49 ERS-57 ERS-68 558-70-06 4 558-70-05 90 55-70-00 4 55-70-00 90 555-70-00 4 555-70-00 90 553-70-003 4 553-70-00 90 554-70-00 4 554-70-00 90 ERS Mounting Flanges (Optional) Model Part No. Pg. No. ERS-6 686-08 93 ERS-4 686-083 93 ERS-49 686-084 93 ERS-57 686-085 93 ERS-68 686-086 93 77 84 84 93 93 93 93 93 Ordering Information Spring-Set Electrically Released Brakes ERS Splined Hubs - ERS Model Bore Size Part No. Pg. No. ERS-6.50 558-54-006 93.3 558-54-007 93.375 558-54-008 93 ERS-4.375 55-54-00 93.500 55-54-003 93.65 55-54-004 93.750 55-54-005 93 ERS-49.375 555-54-00 93.500 555-54-003 93.65 555-54-004 93.750 555-54-005 93.875 555-54-006 93 ERS-57.500 553-54-004 93.65 553-54-005 93.750 553-54-006 93.875 553-54-007 93.000 553-54-008 93 ERS-68.000 554-54-005 93.5 554-54-006 93.50 554-54-007 93.375 554-54-008 93.500 554-54-009 93 Conduit Box 554-0-00 93 EM/ERS Spring-Set Brake Modules Model Part No. Voltage Pg. No. EM-50/ERS-4 EM-50/ERS-49 5370-70- 4 5370-70-3 90 5370-70-4 4 5370-70-5 90 EM-80/ERS-57 5370-70-6 4 96 5370-70-7 90 EM-0/ERS-68 537-70-04 4 96 537-70-043 90 Spring-Set Brakes - ERD Model Part No. Pg. No. ERD 5 00 ERD 0 00 ERD 0 00 ERD 35 00 ERD 60 00 ERD 00 00 ERD 70 00 ERD 300 00 ERD Rectifiers ACG830AP 03 ACG830AP 03 96 96 Warner Electric 800-34-3369 9

Ordering Information Electrically Released Brakes-Permanent Magnet Permanent Magnet Brakes (Dynamic Cycling) Description Model Part No. Voltage Pg. No. FB FB-375-/ FB-375-5/8 FB-475 FB-650 5390-70-0 90 5390-70-04 4 5390-70-0 90 5390-70-03 4 539-70-009 90 539-70-0 4 539-70-007 90 539-70-00 4 07 07 07 07 ER ER-375 Drawing I-5766 90 UniModules - UM-FBC ER-475 Drawing I-5755 90 ER-650 Drawing I-5767 90 ER-85 (N.D.) Drawing I-5577 90 ER-85 (H.D.) Drawing I-5578 90 ER-5 (N.D.) Drawing I-569 36-75 ER-5 (H.D.) Drawing I-560 35-75 Description Model Part No. Voltage Pg. No. Clutch/Brake UM-50-00FBC 5370-73-037 4 0 UniModules 5370-73-036 90 UM-00-00FBC 5370-73-53 4 0 5370-73-5 90 UM-80-00FBC 5370-73-047 4 0 5370-73-046 90 UM-0-00FBC 537-73-03 4 0 537-73-0 90 UM-5-00FBC 5370-73-099 4 537-73-079 90 0 UM-50-030FBC 5370-73-04 4 5370-73-04 90 0 UM-00-030FBC 5370-73-54 4 0 5370-73-55 90 UM-80-030FBC 5370-73-05 4 0 5370-73-05 90 UM-0-030FBC 537-73-08 4 0 537-73-07 90 UM-5-030FBC 537-73-00 4 0 537-73-0 90 Accessories for UM-FBC, EUM-FBB/MBFB, and EM-FBB/FBC/MBFB Description Model Part No. Voltage Pg. No. Conduit Box All Sizes 5370-0-04 09 Controls CBC-60-603-448-00 0 VAC 9 All Sizes CBC-60-603-448-00 0 VAC 9 Base Mount UM-50/00 5370-0-036 Kits UM-80 5370-0-037 030 (FB only) UM-0 537-0-09 Motor Mount EM/UM-50/00 5370-0-00 37, Kits EM/UM-80 37, for 0FBB and EUM-50/00/80 5370-0-0 00FBC EM/EUM/UM-0 37, 537-0-0 EM/EUM/UM-5 Electro Modules Part Numbers Description Model Part No. Voltage Pg. No. Brake Module 5370-69-066 4 EM-50-0FBB 33 5370-69-058 90 Motor Brake Shaft Mounted, Flange Mounted and C-face Compatible Units EM-00-0FBB EM-80-0FBB EM-0-0FBB EM-5-0FBB EM-50-0FBC EM-00-0FBC EM-80-0FBC EM-0-0FBC EM-50-0MBFB EM-00-0MBFB EM-80-0MBFB 5370-69-00 4 5370-69-084 90 5370-69-068 4 5370-69-059 90 537-69-03 4 537-69-09 90 537-69-00 4 537-69-054 90 5370-69-065 4 5370-69-056 90 5370-69-09 4 5370-69-08 90 5370-69-067 4 5370-69-057 90 537-69-03 4 537-69-08 90 5370-69-063 4 5370-69-060 90 5370-69-007 4 5370-69-085 90 5370-69-069 4 5370-69-06 90 33 33 33 33 33 33 33 33 33 33 33 EM-0-7/8-0MBFB 537-69-0 4 33 537-69-07 90 EM-0-0MBFB Enclosed UniModules 537-69-033 4 537-69-030 90 33 Description Model Part No. Voltage Pg. No. Brake EUM-50-0FBB-6 5370-69-983 90 7 Module EUM-50-0FBB-0 5370-69-986 90 7 EUM-00-0FBB- 5370-69-989 90 7 EUM-00-0-FBB- 5370-69-99 90 7 EUM-80-0FBB- 5370-69-995 90 7 EUM-80-0FBB- 5370-69-998 90 7 EUM-0-0FBB-3 537-69-078 90 7 EUM-0-0FBB-56 537-69-08 90 7 EUM-5-0FBB-3 537-69-086 90 7 EUM-5-0FBB-56 537-69-090 90 7 Motor EUM-50-0MBFB-6 5370-69-965 90 7 Brake EUM-50-0MBFB-0 5370-69-968 90 7 EUM-00-0MBFB- 5370-69-97 90 7 EUM-00-0MBFB- 5370-69-974 90 7 EUM-80-0MBFB- 5370-69-977 90 7 EUM-80-0MBFB- 5370-69-980 90 7 EUM-0-7/8-0MBFB-3 537-69-064 90 7 EUM-0-7/8-0MBFB-56 537-69-068 90 7 EUM-0-0MBFB-3 537-69-056 90 7 EUM-0-0MBFB-56 537-69-060 90 7 30 Warner Electric 800-34-3369

Page Model Number Part Number Service Parts Page 75 SFP 50 503-7-00 75 SFP 50 503-7-003 75 SFP 50 503-7-004 75 SFP 50 503-7-005 75 SFP 50 503-7-006 75 SFP 50 503-7-007 75 SFP 50 503-7-008 75 SFP 50 503-7-009 75 SFP 50 503-7-00 75 SFP 50 503-7-0 75 SFP 50 503-7-0 75 SFP 50 503-7-03 75 SFP 400 504-7-006 75 SFP 400 504-7-007 75 SFP 400 504-7-008 75 SFP 400 504-7-009 75 SFP 400 504-7-00 75 SFP 400 504-7-06 75 SFP 400 504-7-07 75 SFP 400 504-7-08 75 SFP 400 504-7-09 75 SFP 400 504-7-00 75 SFP 400 504-7-0 75 SFP 400 504-7-0 75 SFP 400 504-7-03 75 SFP 400 504-7-04 75 SFP 400 504-7-05 77 EP50 530-73-03 06 77 EP50 530-73-03 06 77 EP50 530-73-034 06 84 EP 50C 530-73-053 84 EP 50C 530-73-054 77 EP400 53-73-009 06 77 EP400 53-73-00 06 77 EP400 53-73-0 06 93 ERS 4 55-70-00 93 ERS 4 55-70-00 93 ERS 4 55-54-00 93 ERS 4 55-54-003 93 ERS 4 55-54-004 93 ERS 4 55-54-005 93 ERS 57 553-70-00 93 ERS 57 553-70-003 93 ERS 57 553-54-004 93 ERS 57 553-54-005 93 ERS 57 553-54-006 93 ERS 57 553-54-007 93 ERS 57 553-54-008 93 ERS 68 554-70-00 93 ERS 68 554-70-00 93 ERS 68 554-54-005 93 ERS 68 554-54-006 93 ERS 68 554-54-007 93 ERS 68 554-54-008 93 ERS 68 554-54-009 93 ERS 49 555-70-00 93 ERS 49 555-70-00 93 ERS 49 555-54-00 93 ERS 49 555-54-003 93 ERS 49 555-54-004 93 ERS 49 555-54-005 93 ERS 49 555-54-006 93 ERS 6 558-70-05 93 ERS 6 558-70-06 Service Parts Index Page Model Number Part Number Service Parts Page 93 ERS 6 558-54-006 93 ERS 6 558-54-007 93 ERS 6 558-54-008 69 ATC5 56-7-00 0 69 ATC5 56-7-003 0 69 ATC5 56-7-004 0 69 ATC5 56-7-005 0 69 ATC5 56-7-006 0 69 ATC5 56-7-007 0 69 ATC5 56-7-008 0 69 ATC5 56-7-009 0 69 ATC5 56-7-00 0 69 ATC5 56-7-0 0 69 ATC5 56-7-0 0 69 ATC5 56-7-03 0 69 ATC55 56-7-00 0 69 ATC55 56-7-003 0 69 ATC55 56-7-004 0 69 ATC55 56-7-005 0 69 ATC55 56-7-006 0 69 ATC55 56-7-007 0 69 ATC55 56-7-008 0 69 ATC55 56-7-009 0 69 ATC55 56-7-00 0 69 ATC55 56-7-0 0 69 ATC55 56-7-0 0 69 ATC55 56-7-03 0 69 ATC5 563-7-00 0 69 ATC5 563-7-003 0 69 ATC5 563-7-004 0 69 ATC5 563-7-005 0 69 ATC5 563-7-006 0 69 ATC5 563-7-007 0 69 ATC5 563-7-008 0 69 ATC5 563-7-009 0 69 ATC5 563-7-00 0 69 ATC5 563-7-0 0 69 ATC5 563-7-0 0 69 ATC5 563-7-03 0 53 EC375 580-7-00 90 53 EC375 580-7-004 90 53 EC375 580-7-005 90 53 EC375 580-7-006 90 53 EC375 580-7-008 90 53 EC375 580-7-009 90 53 EC475 58-7-00 90 53 EC475 58-7-003 90 53 EC475 58-7-004 90 53 EC475 58-7-005 90 53 EC475 58-7-006 90 53 EC475 58-7-007 90 53 EC475 58-7-008 90 53 EC475 58-7-009 90 53 EC475 58-7-00 90 7 ATB5 59-70-00 04 7 ATB5 59-70-003 04 7 ATB5 59-70-004 04 7 ATB5 59-70-005 04 7 ATB5 59-70-006 04 7 ATB5 59-70-007 04 7 ATB5 59-70-008 04 7 ATB5 59-70-009 04 7 ATB5 59-70-00 04 7 ATB5 59-70-0 04 Warner Electric 800-34-3369 3

Index Page Model Number Part Number Service Parts Page 7 ATB5 59-70-0 04 7 ATB5 59-70-03 04 7 ATB55 59-70-00 04 7 ATB55 59-70-003 04 7 ATB55 59-70-004 04 7 ATB55 59-70-005 04 7 ATB55 59-70-006 04 7 ATB55 59-70-007 04 7 ATB55 59-70-008 04 7 ATB55 59-70-009 04 7 ATB55 59-70-00 04 7 ATB55 59-70-0 04 7 ATB55 59-70-0 04 7 ATB55 59-70-03 04 7 ATB5 593-70-00 04 7 ATB5 593-70-003 04 7 ATB5 593-70-004 04 7 ATB5 593-70-005 04 7 ATB5 593-70-006 04 7 ATB5 593-70-007 04 7 ATB5 593-70-008 04 7 ATB5 593-70-009 04 7 ATB5 593-70-00 04 7 ATB5 593-70-0 04 7 ATB5 593-70-0 04 7 ATB5 593-70-03 04 77 EP500 530-73-00 08 77 EP500 530-73-003 08 77 EP500 530-73-0 08 77 EP85 53-73-00 09 77 EP85 53-73-003 09 77 EP85 53-73-004 09 77 EP000 53-73-00 0 77 EP000 53-73-003 0 77 EP000 53-73-005 0 77 EP55 534-73-00 77 EP55 534-73-003 77 EP55 HT 534-73-0 77 EP55 HT 534-73-07 4 ER85 550-5 7 4 ER85 550-30 7 4 ER5 55-4 7 4 ER5 55-9 7 3 ER375 554-6 3 ER475 555-5 6 3 ER475 555-6 6 3 ER650 556-6 6 3 ER650 556-7 6 53 EC650 58-7-00 90 53 EC650 58-7-003 90 53 EC650 58-7-004 90 53 EC650 58-7-005 90 53 EC650 58-7-006 90 53 EC650 58-7-007 90 53 EC650 58-7-008 90 53 EC650 58-7-009 90 53 EC650 58-7-06 90 53 EC650 58-7-08 90 53 EC650 58-7-09 90 53 EC650 58-7-00 90 53 EC85 58-7-00 9 53 EC85 58-7-003 9 53 EC85 58-7-004 9 53 EC85 58-7-008 9 Page Model Number Part Number Service Parts Page 53 EC85 58-7-009 9 53 EC85 58-7-00 9 53 EC85 58-7-0 9 53 EC85 58-7-0 9 53 EC85 58-7-03 9 53 EC000 583-7-00 94 53 EC000 583-7-003 94 53 EC000 583-7-004 94 53 EC000 583-7-005 94 53 EC000 583-7-00 94 53 EC000 583-7-0 94 53 EC000 583-7-0 94 53 EC000 583-7-03 94 53 EC5 584-7-00 94 53 EC5 584-7-003 94 53 EC5 584-7-004 94 53 EC5 584-7-005 94 53 EC5 584-7-008 94 53 EC5 584-7-00 94 53 EC5 584-7-03 94 53 EC5 584-7-04 94 53 EC5 584-7-05 94 7 UM-50-00/CBC-50 5370-9 76 7 UM00-00/CBC50 5370-0 76 33 EM 00-0MBFB 5370-69-007 3 33 EM 00-0FBB 5370-69-00 3 EM00-0 5370-69-040 70 3 EM00-0 5370-69-04 70 3 EM50-0 5370-69-04 70 3 EM50-0 5370-69-043 70 3 EM50-0 5370-69-045 70 3 EM50-0MB 5370-69-047 7 3 EM50-0MB 5370-69-048 7 3 EM80-0 5370-69-050 70 3 EM80-0 5370-69-05 70 3 EM80-0MB 5370-69-053 7 3 EM80-0MB 5370-69-054 7 33 EM 50-0FBC 5370-69-056 4 33 EM 80-0FBC 5370-69-057 4 33 EM 50-0FBB 5370-69-058 33 EM 80-0FBB 5370-69-059 33 EM 50-0MBFB 5370-69-060 3 33 EM 80-0MBFB 5370-69-06 3 3 EM50-0MB 5370-69-06 7 33 EM 50-0MBFB 5370-69-063 3 33 EM 50-0FBC 5370-69-065 4 33 EM 50-0FBB 5370-69-066 33 EM 80-0FBC 5370-69-067 4 33 EM 80-0FBB 5370-69-068 33 EM 80-0MBFB 5370-69-069 3 3 EM80-0 5370-69-07 70 3 EM00-0 5370-69-07 70 3 EM80-0MB 5370-69-073 7 33 EM 00-0FBB 5370-69-084 33 EM 00-0MBFB 5370-69-085 3 33 EM 00-0FBC 5370-69-08 4 33 EM 00-0FBC 5370-69-09 4 7 EUM50-0MBFB-6 5370-69-965 7 EUM50-0MBFB-0 5370-69-968 7 EUM00-0MBFB- 5370-69-97 7 EUM00-0MBFB- 5370-69-974 7 EUM80-0MBFB- 5370-69-977 7 EUM80-0MBFB- 5370-69-980 7 EUM50-0FBB-6 5370-69-983 Service Parts 3 Warner Electric 800-34-3369

Page Model Number Part Number Service Parts Page 7 EUM50-0FBB-0 5370-69-986 7 EUM00-0FBB- 5370-69-989 7 EUM-00-0FBB- 5370-69-99 7 EUM80-0FBB- 5370-69-995 7 EUM80-0FBB- 5370-69-998 96 EM 50/ERS-4 5370-70- 96 EM 50/ERS-4 5370-70-3 96 EM 50/ERS-49 5370-70-4 96 EM 50/ERS-49 5370-70-5 96 EM 80/ERS-57 5370-70-6 96 EM 80/ERS-57 5370-70-7 3 EM50-0 5370-70-05 69 3 EM50-30 5370-70-06 74 3 EM80-0 5370-70-07 69 3 EM50-30 5370-70-09 74 3 EM50-0 5370-70-00 69 3 EM80-0 5370-70-0 69 3 EM50-0 5370-70-030 69 3 EM00-0 5370-70-045 69 3 EM00-0 5370-70-046 69 3 EM00-30 5370-70-047 74 3 EM00-30 5370-70-048 74 3 EM80-30 5370-70-049 74 3 EM80-30 5370-70-050 74 3 EM 50-30 5370-70-05 74 3 EM80-30 5370-70-053 74 3 EM00-30 5370-70-054 74 3 EM80-0 5370-70-055 69 3 EM00-0 5370-70-056 69 7 UM 50-040 5370-7-004 78 7 UM 50-040 5370-7-005 78 7 UM 50-040 5370-7-006 78 7 UM 50-3040 5370-7-009 8 7 UM 50-3040 5370-7-00 8 7 UM 50-3040 5370-7-0 8 7 UM80-040 5370-7-04 78 7 UM80-040 5370-7-05 78 7 UM80-040 5370-7-06 78 7 UM80-3040 5370-7-09 8 7 UM80-3040 5370-7-00 8 7 UM80-3040 5370-7-0 8 7 UM00-040 5370-7-04 78 7 UM00-040 5370-7-05 78 7 UM00-040 5370-7-06 78 7 UM00-3040 5370-7-09 8 7 UM00-3040 5370-7-030 8 7 UM00-3040 5370-7-03 8 46 EUM 50-040 5370-7-050 86 46 EUM80-040 5370-7-05 86 7 UM 80-00 5370-73-006 76 7 UM 80-00 5370-73-007 76 7 UM 80-00 5370-73-008 76 7 UM 80-030 5370-73-0 80 7 UM 80-030 5370-73-0 80 7 UM 80-030 5370-73-03 80 7 UM 50-00 5370-73-06 76 7 UM 50-00 5370-73-07 76 7 UM 50-00 5370-73-08 76 7 UM 50-030 5370-73-0 80 7 UM 50-030 5370-73-0 80 7 UM 50-030 5370-73-03 80 7 UM 00-00 5370-73-06 76 7 UM 00-00 5370-73-07 76 7 UM 00-00 5370-73-08 76 Index Page Model Number Part Number Service Parts Page 7 UM 00-030 5370-73-03 80 7 UM 00-030 5370-73-03 80 7 UM 00-030 5370-73-033 80 0 UM 50-00FBC 5370-73-036 8 0 UM 50-00FBC 5370-73-037 8 0 UM 50-030FBC 5370-73-04 0 0 UM 50-030FBC 5370-73-04 0 0 UM 80-00FBC 5370-73-046 8 0 UM 80-00FBC 5370-73-047 8 0 UM 80-030FBC 5370-73-05 0 0 UM 80-030FBC 5370-73-05 0 46 EUM 50-00 5370-73-057 84 46 EUM 50-00 5370-73-058 84 46 EUM 50-00 5370-73-059 84 46 EUM 50-030 5370-73-06 88 46 EUM 50-030 5370-73-06 88 46 EUM 50-030 5370-73-063 88 46 EUM80-00 5370-73-065 84 46 EUM80-00 5370-73-066 84 46 EUM80-00 5370-73-067 84 46 EUM80-030 5370-73-069 88 46 EUM80-030 5370-73-070 88 46 EUM80-030 5370-73-07 88 37 UM 80-00C 5370-73-073 37 UM 80-00C 5370-73-074 37 UM 80-00C 5370-73-075 37 UM 50-00C 5370-73-077 37 UM 50-00C 5370-73-078 37 UM 50-00C 5370-73-079 37 UM 80-030C 5370-73-08 37 UM 80-030C 5370-73-08 37 UM 80-030C 5370-73-083 37 UM 50-030C 5370-73-085 37 UM 50-030C 5370-73-086 37 UM 50-030C 5370-73-087 46 EUM00-00 5370-73-09 84 46 EUM00-00 5370-73-09 84 46 EUM00-00 5370-73-093 84 46 EUM 50-00W 5370-73-099 84 46 EUM 50-00W 5370-73-00 84 46 EUM 50-00W 5370-73-0 84 46 EUM 50-030W 5370-73-03 88 46 EUM 50-030W 5370-73-04 88 46 EUM 50-030W 5370-73-05 88 46 EUM00-00W 5370-73-07 84 46 EUM00-00W 5370-73-08 84 46 EUM00-00W 5370-73-09 84 46 EUM80-00W 5370-73-5 84 46 EUM80-00W 5370-73-6 84 46 EUM80-00W 5370-73-7 84 46 EUM80-030W 5370-73-9 88 46 EUM80-030W 5370-73-0 88 46 EUM80-030W 5370-73- 88 7 UM 80-00/CBC50 5370-73- 76 0 UM 00-00FBC 5370-73-5 8 0 UM 00-00FBC 5370-73-53 8 0 UM 00-030FBC 5370-73-54 8 0 UM 00-030FBC 5370-73-55 8 3 EM00-40 5370-536-007 75 3 EM 50-40 5370-536-008 75 3 EM80-40 5370-536-009 75 7 UM 50-00/CBC50 5370-9 76 3 EM 0-0 537-69-0 70 3 EM 0-0 537-69-03 70 Service Parts Warner Electric 800-34-3369 33

Packaged Products Page Model Number Part Number Service Parts Page 3 EM 0-0MB 537-69-05 7 3 EM 0-0MB 537-69-06 7 33 EM 0-0FBC 537-69-08 4 33 EM 0-0FBB 537-69-09 33 EM 0-0MBFB 537-69-030 3 33 EM 0-0FBC 537-69-03 4 33 EM 0-0FBB 537-69-03 33 EM 0-0MBFB 537-69-033 3 3 EM 0-0 537-69-034 70 3 EM 0-0MB 537-69-035 7 33 EM 5-0FBB 537-69-054 7 EUM 0-0MBFB-3 537-69-056 7 EUM 0-0MBFB-56 537-69-060 7 EUM 0-7/8-0MBFB-3 537-69-064 7 EUM 0-7/8-0MBFB-56 537-69-068 33 EM 0-7/8-0MBFB 537-69-07 3 3 EM 5-0 537-69-076 70 7 EUM 0-0FBB-3 537-69-078 7 EUM 0-0FBB-56 537-69-08 7 EUM 5-0FBB-3 537-69-086 7 EUM 5-0FBB-56 537-69-090 33 EM 5-0FBB 537-69-00 33 EM 0-7/8-0MBFB 537-69-0 3 96 EM 0/ERS-68 537-70-04 96 EM 0/ERS-68 537-70-043 3 EM 0-0 537-70-009 69 3 EM 0-0 537-70-0 69 3 EM 0-30 537-70-03 74 3 EM 0-30 537-70-04 74 3 EM 0-30 537-70-06 74 3 EM 0-0 537-70-07 69 7 UM 0-040 537-7-00 78 7 UM 0-040 537-7-003 78 7 UM 0-040 537-7-004 78 7 UM0-3040 537-7-007 8 7 UM0-3040 537-7-008 8 7 UM0-3040 537-7-009 8 7 UM5-3040 537-7-0 8 7 UM5-3040 537-7-0 8 7 UM5-3040 537-7-03 8 46 EUM0-040 537-7-04 86 7 UM5-040 537-7-06 78 7 UM5-040 537-7-07 78 7 UM5-040 537-7-08 78 7 UM0-00 537-73-00 76 7 UM0-00 537-73-003 76 7 UM0-00 537-73-004 76 7 UM0-030 537-73-007 80 7 UM0-030 537-73-008 80 7 UM0-030 537-73-009 80 0 UM0-00FBC 537-73-0 8 0 UM0-00FBC 537-73-03 8 0 UM0-030FBC 537-73-07 0 0 UM0-030FBC 537-73-08 0 46 EUM0-00 537-73-07 84 46 EUM0-00 537-73-08 84 46 EUM0-00 537-73-09 84 46 EUM0-030 537-73-03 88 46 EUM0-030 537-73-03 88 46 EUM0-030 537-73-033 88 37 UM 0-00C 537-73-035 37 UM 0-00C 537-73-036 37 UM 0-00C 537-73-037 37 UM 0-030C 537-73-039 Service Parts 34 Warner Electric 800-34-3369 Page Model Number Part Number Service Parts Page 37 UM 0-030C 537-73-040 37 UM 0-030C 537-73-04 7 UM5-030 537-73-043 80 7 UM5-030 537-73-044 80 7 UM5-030 537-73-045 80 46 EUM0-00W 537-73-055 84 46 EUM0-00W 537-73-056 84 46 EUM0-00W 537-73-057 84 46 EUM0-030W 537-73-059 88 46 EUM0-030W 537-73-060 88 46 EUM0-030W 537-73-06 88 7 UM5-00 537-73-076 76 7 UM5-00 537-73-077 76 7 UM5-00 537-73-078 76 0 UM5-00FBC 537-73-079 46 EUM5-00 537-73-08 84 46 EUM5-00 537-73-083 84 46 EUM5-00 537-73-084 84 46 EUM5-00W 537-73-086 84 46 EUM5-00W 537-73-087 84 46 EUM5-00W 537-73-088 84 7 UM5-00/CBC50 537-73-090 76 0 UM 5-030FBC 537-73-00 8 0 UM 5-030FBC 537-73-0 8 7 UM0-00/CBC50 537-4 76 3 EM0-40 537-536-005 75 46 EUM0-00W 537-73-055 84 59 EB375 5380-70-00 96 59 EB375 5380-70-003 96 59 EB375 5380-70-004 96 59 EB375 5380-70-005 96 59 EB375 5380-70-006 96 59 EB375 5380-70-007 96 59 EB475 538-70-00 96 59 EB475 538-70-003 96 59 EB475 538-70-004 96 59 EB650 538-70-00 96 59 EB650 538-70-003 96 59 EB650 538-70-005 96 59 EB85 5383-70-00 98 59 EB85 5383-70-004 98 59 EB85 5383-70-005 98 59 EB000 5384-70-00 00 59 EB000 5384-70-003 00 59 EB000 5384-70-005 00 59 EB5 5385-70-00 00 59 EB5 5385-70-003 00 59 EB5 5385-70-005 00 07 FB375 5390-70-0 4 07 FB375 5390-70-0 4 07 FB375 5390-70-03 4 07 FB375 5390-70-04 4 07 FB475 539-70-009 4 07 FB475 539-70-0 4 07 FB650 539-70-007 4 07 FB650 539-70-00 4 77 EP70 5633-73-00 06 77 EP70 5633-73-003 06 77 EP70 5633-73-005 06 84 EP 70C 5633-73-08 84 EP 70C 5633-73-09

Browning Bushing Shaft Size Keyway Size Electric 8 x 6 80-000 9 6 8 x 6 80-0003 5 8 3 6 x 3 3 80-0004 6 3 6 x 3 3 80-0005 3 4 3 6 x 3 3 80-0006 3 6 3 6 x 3 3 80-0007 7 8 3 6 x 3 3 80-0008 5 6 4 x 8 80-0009 4 x 8 80-000 6 4 x 8 80-00 8 4 x 8 80-00 3 6 4 x 8 80-003 4 4 x 8 80-004 5 6 5 6 x 5 3 80-005 3 8 5 6 x 5 3 80-006 7 6 3 8 x 3 6 80-007 3 8 x 3 6 80-008 3 4 3 6 x 3 3 80-006 3 6 3 6 x 3 3 80-007 7 8 3 6 x 3 3 80-008 5 6 4 x 8 80-009 4 x 8 80-0030 6 4 x 8 80-003 8 4 x 8 80-003 3 6 4 x 8 80-0033 4 4 x 8 80-0034 5 6 5 6 x 5 3 80-0035 3 8 5 6 x 5 3 80-0036 7 6 3 8 x 3 6 80-0037 3 8 x 3 6 80-0038 9 6 3 8 x 3 6 80-0039 5 8 3 8 x 3 6 80-0040 6 3 8 x 3 6 80-004 3 4 3 8 x 3 6 80-004 3 6 x 4 80-0043 7 8 x 4 80-0044 5 6 x 4 80-0045 x 4 80-0046 6 x 4 80-0047 8 x 4 80-0048 3 6 x 4 80-0049 4 x 4 80-0050 5 6 5 8 x 5 6 80-005 3 8 5 8 x 5 6 80-005 7 6 5 8 x 5 6 80-0053 5 8 x 5 6 80-0054 9 6 5 8 x 5 6 80-0055 5 8 5 8 x 5 6 80-0056 6 5 8 x 5 6 80-0057 (Browning is registered to Emerson Electric Co.) Bushing Number Warner Browning H Type- H Type- Q Type- Q Type- Dodge Bushing Shaft Size Bushing Part Numbers Keyway Size Electric 8 x 6 80-00 9 6 8 x 6 80-00 5 8 3 6 x 3 3 80-003 6 3 6 x 3 3 80-004 3 4 3 6 x 3 3 80-005 3 6 3 6 x 3 3 80-006 7 8 3 6 x 3 3 80-007 5 6 4 x 8 80-008 4 x 8 80-009 6 4 x 8 80-00 8 4 x 8 80-0 3 6 4 x 8 80-0 4 4 x 8 80-03 8 x 6 80-06 9 6 8 x 6 80-07 5 8 3 6 x 3 3 80-08 6 3 6 x 3 3 80-09 3 4 3 6 x 3 3 80-00 3 6 3 6 x 3 3 80-0 7 8 3 6 x 3 3 80-0 5 6 4 x 8 80-03 4 x 8 80-04 6 4 x 8 80-05 8 4 x 8 80-06 3 6 4 x 8 80-07 4 4 x 8 80-08 8 x 6 80-03 9 6 8 x 6 80-03 5 8 3 6 x 3 3 80-033 6 3 6 x 3 3 80-034 3 4 3 6 x 3 3 80-035 3 6 3 6 x 3 3 80-036 7 8 3 6 x 3 3 80-037 5 6 4 x 8 80-038 4 x 8 80-039 6 4 x 8 80-040 8 4 x 8 80-04 3 6 4 x 8 80-04 4 4 x 8 80-043 5 6 5 6 x 5 3 80-044 3 8 5 6 x 5 3 80-045 7 6 3 8 x 3 6 80-046 3 8 x 3 6 80-047 9 6 3 8 x 3 6 80-048 5 8 3 8 x 3 6 80-049 8 x 6 80-055 9 6 8 x 6 80-056 5 8 3 6 x 3 3 80-057 6 3 6 x 3 3 80-058 3 4 3 6 x 3 3 80-059 3 6 3 6 x 3 3 80-060 7 8 3 6 x 3 3 80-06 5 6 4 x 8 80-06 4 x 8 80-063 6 4 x 8 80-064 8 4 x 8 80-065 3 6 4 x 8 80-066 4 4 x 8 80-067 Bushing Number Warner Dodge 0 5 65 0 Service Parts Warner Electric 800-34-3369 35

Bushing Part Numbers Shaft Size Keyway Size Bushing Number Warner Dodge Electric 5 6 5 6 x 5 3 80-068 3 8 5 6 x 5 3 80-069 7 6 3 8 x 3 6 80-070 3 8 x 3 6 80-07 9 6 3 8 x 3 6 80-07 5 8 3 8 x 3 6 80-073 6 3 8 x 3 6 80-074 3 4 3 8 x 3 6 80-075 3 6 x 4 80-076 7 8 x 4 80-077 5 6 x 4 80-078 x 4 80-079 8 x 6 80-085 9 6 8 x 6 80-086 5 8 3 6 x 3 3 80-087 6 3 6 x 3 3 80-088 3 4 3 6 x 3 3 80-089 3 6 3 6 x 3 3 80-090 7 8 3 6 x 3 3 80-09 5 6 4 x 8 80-09 4 x 8 80-093 6 4 x 8 80-094 8 4 x 8 80-095 3 6 4 x 8 80-096 4 4 x 8 80-097 5 6 5 6 x 5 3 80-098 3 8 5 6 x 5 3 80-099 7 6 3 8 x 3 6 80-000 3 8 x 3 6 80-00 9 6 3 8 x 3 6 80-00 5 8 3 8 x 3 6 80-003 6 3 8 x 3 6 80-004 3 4 3 8 x 3 6 80-005 3 6 x 4 80-006 7 8 x 4 80-007 5 6 x 4 80-008 x 4 80-009 6 x 4 80-00 8 x 4 80-0 3 6 x 4 80-0 4 x 4 80-03 5 6 5 8 x 5 6 80-04 3 8 5 8 x 5 6 80-05 7 6 5 8 x 5 6 80-06 5 8 x 5 6 80-07 5 6 4 x 8 80-03 4 x 8 80-04 6 4 x 8 80-05 8 4 x 8 80-06 3 6 4 x 8 80-07 4 4 x 8 80-08 5 6 5 6 x 5 3 80-09 3 8 5 6 x 5 3 80-030 7 6 3 8 x 3 6 80-03 3 8 x 3 6 80-03 9 6 3 8 x 3 6 80-033 5 8 3 8 x 3 6 80-034 0 57 300 Shaft Size Keyway Size Bushing Number Warner Dodge Electric 6 3 8 x 3 6 80-035 3 4 3 8 x 3 6 80-036 3 6 x 4 80-037 7 8 x 4 80-038 5 6 x 4 80-039 x 4 80-040 6 x 4 80-04 8 x 4 80-04 3 6 x 4 80-043 4 x 4 80-044 5 6 5 8 x 5 6 80-045 3 8 5 8 x 5 6 80-046 7 6 5 8 x 5 6 80-047 5 8 x 5 6 80-048 9 6 5 8 x 5 6 80-049 5 8 5 8 x 5 6 80-050 6 5 8 x 5 6 80-05 3 4 5 8 x 5 6 80-05 3 6 3 4 x 3 8 80-053 7 8 3 4 x 3 8 80-054 5 6 3 4 x 3 8 80-055 3 3 4 x 3 8 80-056 5 6 4 x 8 80-06 4 x 8 80-063 6 4 x 8 80-064 8 4 x 8 80-065 3 6 4 x 8 80-066 4 4 x 8 80-067 5 6 5 6 x 5 3 80-068 3 8 5 6 x 5 3 80-069 7 6 3 8 x 3 6 80-070 3 8 x 3 6 80-07 9 6 3 8 x 3 6 80-07 5 8 3 8 x 3 6 80-073 6 3 8 x 3 6 80-074 3 4 3 8 x 3 6 80-075 3 6 x 4 80-076 7 8 x 4 80-077 5 6 x 4 80-078 x 4 80-079 6 x 4 80-080 8 x 4 80-08 3 6 x 4 80-08 4 x 4 80-083 5 6 5 8 x 5 6 80-084 3 8 5 8 x 5 6 80-085 7 6 5 8 x 5 6 80-086 5 8 x 5 6 80-087 9 6 5 8 x 5 6 80-088 5 8 5 8 x 5 6 80-089 6 5 8 x 5 6 80-090 3 4 5 8 x 5 6 80-09 3 6 3 4 x 3 8 80-09 7 8 3 4 x 3 8 80-093 5 6 3 4 x 3 8 80-094 3 3 4 x 3 8 80-095 300 3030 Shaft Size Keyway Size Bushing Number Warner Dodge Electric 8 x 6 80-036 9 6 8 x 6 80-037 5 8 3 6 x 3 3 80-038 6 3 6 x 3 3 80-039 3 4 3 6 x 3 3 80-0330 3 6 3 6 x 3 3 80-033 7 8 3 6 x 3 3 80-033 5 6 4 x 8 80-0333 4 x 8 80-0334 6 4 x 8 80-0335 8 4 x 8 80-0336 3 6 4 x 8 80-0337 4 4 x 8 80-0338 5 6 5 6 x 5 3 80-0339 3 8 5 6 x 5 3 80-0340 7 6 3 8 x 3 6 80-034 3 8 x 3 6 80-034 9 6 3 8 x 3 6 80-0343 5 8 3 8 x 3 6 80-0344 8 x 6 80-040 9 6 8 x 6 80-04 5 8 3 6 x 3 3 80-04 6 3 6 x 3 3 80-043 3 4 3 6 x 3 3 80-044 3 6 3 6 x 3 3 80-045 7 8 3 6 x 3 3 80-046 5 6 4 x 8 80-047 4 x 8 80-048 8 x 6 80-04 9 6 8 x 6 80-04 5 8 3 6 x 3 3 80-043 6 3 6 x 3 3 80-044 3 4 3 6 x 3 3 80-045 3 6 3 6 x 3 3 80-046 7 8 3 6 x 3 3 80-047 5 6 4 x 6 80-048 4 x 8 80-049 6 4 x 8 80-0430 8 4 x 8 80-043 3 6 4 x 8 80-043 4 4 x 8 80-0433 5 6 5 6 x 5 3 80-0434 3 8 5 6 x 5 3 80-0435 60 008 30 Service Parts 36 Warner Electric 800-34-3369

Other Warner Electric Clutch/Brake Products Warner Electric engineers, manufactures and markets, electromechanical components and systems for controlling motion. Designed to help increase productivity, our products are incorporated into new equipment designs and are used to upgrade performance on machines already in service. With an international organization of stocking distributors and sales centers, Warner Electric offers the most extensive network of its kind for locally available products and professional, on-the-spot customer service. Basic Design Clutches/Brakes Electromagnetic clutches and brakes Custom design with off-the-shelf components Maximum mounting versatility Wide range of sizes, torque ratings and configurations Ideal for space restrictive applications Catalog P-64 Tension Control Systems Up to,500 lb. ft. stopping torque Complete system for unwind applications Patented, new technology electric brakes Sophisticated control systems Load cell controls Accurate, smooth, long life Magnetic Particle Clutches & Brakes Torque range in. lb. to 40 in. lb. For controlled starts and stops, tension control, torque limiting and cycling applications High thermal ratings Smooth, quiet frictionless operation Catalog P-77 Wrap Spring Clutches and Clutch/Brakes Accurate positioning with high torqueto-size ratio Long life, Maintenance free Fast, repeatable performance Pre-assembled, easy to install Torque range from 5 lb.in. to,500 lb.in. Over 5 sizes available Catalog P-30 Overrunning Clutches Torque loads to 700,000 lb. ft. (94900 Nm) Overrunning, indexing and backstopping applications Instantaneous action, no backlash More torque, less space Full sprag complement with infinitely changing wear parts Catalog P-956 Precision Tork Fast, precise torque Smooth, consistent torque to speed No external control or power source required Long life, accurate Versatile mounting: Easy to retrofit Off-the-shelf availability Catalog P-36 Sensors, Switches & Safety Technology Products Full line of Sensing, Switching and Safety Technology Products Non Contact Photoelectric, Ultrasonic, Inductive, Capacitive and Magnetic Sensors Contact Limit Switches, Footswitches, Cable Pull Switches, and Conveyor Belt Alignment Switches Safety Switches Safety Interlock Switches (key and hinge styles), Solenoid Lock, Spring Lock, Cable Pull, Footswitch and Coded Magnetic Safety Switches Catalog P-0A ERD Designed to keep load in position in the event of power failure Sizes from 3.3 in. to 9.9 in., 4 to ft.lbs. of torque Stops loads from speeds up to 3600 RPM Quiet operation Bi-directional stopping capability Metric and inch standard bore sizes Catalog P-083

Warner Electric Electromagnetic Clutches and Brakes - USA South Beloit, IL 6080 85-389-377 For application assistance: -800-85-9050 Electromagnetic Clutches and Brakes - Europe St Barthelemy d Anjou, France +33 (0) 4 4 4 For sales office: +33 (0) 4 4 76 Precision Electric Coils and Electromagnetic Clutches and Brakes - USA Columbia City, IN 4675 60-44-683 Inertia Dynamics Spring Set Brakes; Power On and Wrap Spring Clutch/Brakes Torrington, CT 06790 860-48-4444 Matrix International Electromagnetic Clutches and Brakes, Pressure Operated Clutches and Brakes Brechin, Scotland +44 (0) 356 60000 Warner Linear Linear Actuators and Guideways - USA Belvidere, IL 6008 85-547-06 For application assistance: -800-85-9050 Boston Gear Enclosed and Open Gearing, Electrical and Mechanical P.T. Components, Precision Gearheads, Precision Couplings Quincy, MA 07 67-38-3300 For customer service: -888-999-9860 For application assistance: -800-86-5608 Huco Dynatork Precision Couplings and Air Motors Hertford, England +44 (0) 99 50900 Formsprag Clutch Overrunning Clutches and Holdbacks Warren, MI 48089 586-758-5000 For application assistance: -800-97-36 Marland Clutch Roller Ramp and Sprag Type Overrunning Clutches and Backstops Burr Ridge, IL 6057 630-455-75 Stieber Clutch Overrunning Clutches and Holdbacks Heidelberg, Germany +49 (0)6 30 47 0 Wichita Clutch and Industrial Clutch Pneumatic and Oil Immersed Clutches and Brakes - USA Wichita Falls, TX 7630 940-73-3400 Pneumatic Clutches and Brakes - Europe Bedford, England +44 (0)34 3503 Twiflex Limited Caliper Brakes and Thrusters Twickenham, England +44 (0) 0 8894 6 Ameridrives Couplings Gear Couplings, Mill Spindles, Universal Joints Erie, PA 65 84-480-5000 Bibby Transmissions Disc, Gear, Grid Couplings, Overload Clutches Dewsbury, England +44 (0) 94 46080 Nuttall Gear and Delroyd Worm Gear Worm Gear and Helical Speed Reducers Niagara Falls, NY 430 76-98-400 Saftek Friction Non-asbestos Brake and Clutch Materials Telford, England +44 (0) 95 58 Altra Industrial Motion - Asia Pacific and Africa China 85 65 933 Taiwan 886 577 856 Singapore 65 487 4464 Thailand 66 3 048 Australia 6 9894 033 S. Africa 7 98 470 www.warnerelectric.com Warner Electric, Inc. 449 Gardner Street South Beloit, IL 6080 85-389-377 Fax: 85-389-58 www.warnerelectric.com P-34 8/0**** Printed in USA