Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

Similar documents
Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

EM DC Multi-Function DC Energy Meter

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Powerterm L120C Single Output PSU/Battery Chargers Model C2199A-1 (12V/8A) or Model C2199A-2 (24V/6A)

premier product range

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Surface mounting, flush mounting, and DIN track mounting

Electronic timers CT-E range Selection and ordering details

SonoMeter 30 Energy Meters

SonoMeter 30 Energy Meters

DGC-2020 DIGITAL GENSET CONTROLLER

RVS-DN Digital Reduced Voltage Motor Starter

MCD 200 Series Soft Starters

SD Series Non-Fused Load Switches

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

Industrial Power Supplies

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A

LDX-C120 Series is a 120 W integrated DIN Rail Battery Charger / DC UPS Power Supplies, suitable for wide variety of industrial applications.

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

Safety technique. Emergency Stop Module BH 5928, BI 5928

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Technical Data Sheets

Technical Data Sheets

Electronic timers CT-S range Function diagrams

Technical Data Sheets

M Series 140.D Data Sheet. Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial RW 96 RP 96

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

AC/DC Converter MBP250-2A13D13M

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

1 potential-free change-over contact (max. 24 V DC/1 A) for SIL collective failure signal SIL functions - safety functions Standard: Safe ESD

DIN Panel Meters Long Scale

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

IRT 4000 AT-S/M/L. Technical Manual. quality IN MOTION. quality IN MOTION

Technical Data Sheets

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Pneumatic Timer. TECHNICAL DATA Display digit roll s, s or s, depending on version Operating pressure 2...

Stepping Motor and Driver Package. High-Efficiency AR Series. DC Power-Supply Input. Built-in Controller Type Pulse Input Type

Transfer switch OTEC open or delayed transition

Lexium integrated drives

LDX-U20 is a microprocessor controlled DC-UPS rated 20 A usable in 12 V or 24 V systems.

EG1299. Variable Speed Engine Controller for Telecom Backup Gensets SEDEMAC EG1299 HIGHLIGHTS

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

OPERATING INSTRUCTIONS ECON-M

CTi Automation - Phone: Fax: Web:

D509E. Manual Motor - Starters

MagFlux Q 8200 Series

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

EPS/ELA-Series User Manual EPS/ELA 250W

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

3. Input KJ: Thermocouple P: Platinum resistance thermometer G: Thermistor T: Thermocouple/platinum resistance thermometer (universal-input)

Technical Data Sheets

Digital Time Switches

Micro Controller based Motor Protection Relay & Motor Management System

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

USERS MANUAL MCD REMOTE OPERATOR

CP Automatic capacitor bank

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

Scheda prodotto Relè Series E

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

AuCom - Soft Starters

Acuvim-L Series. Multifunction Power Meter. Max & Min

825-P Modular Protection System for motors Specification Guide

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Cat N 3. OVERALL DIMENSIONS

Lexium integrated drives

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

M Series 010.D Data Sheet. Analog Meters with Moving-Coil Movement, 90 Dial PSQ 48 PQ 72 RS PQ 96 RS PQ 144 RS

HMI Components. Series. Indicator Illuminated pushbutton Mushroom-head pushbutton Key lock switch

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

Energy Storage System for Home

RVS-DX Digital Reduced Voltage Motor Starter

HIGH POWER SOLENOID DRIVER 1

POWERTRONIX QUASAR 5-40 KVA

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

SIGMA SERIES DE METER

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

3 Uninterruptible Power Systems

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

ALR output Powerfull PROGRAMMABLE POWER SUPPLY 640 WATTS 0-32V 0-20A POWERFUL. Specifications

INTECH Micro 2300-RTD6

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Energy Storage System for Home. High Efficiency - Peak efficiency 97.3% Bi-directional DC-DC converter

POWER SUPPLIES. Control Transformers p8-1 Modular Power Supplies p8-2 Switching Power Supplies p8-3 Automatic Battery Chargers p PAGE

Defining a timer in simple terms. Which actions are executed? Which market are they used frequently? Benefits and Advantages

Open Frame Power Supplies

SmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA

A21M. Introduction: Functional Overview: Key Protection & Control Functions:

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

OTEC Transfer switch open transition

Transcription:

Preliminary Datasheet Technical Datasheet Compact DC Energy Meter RISH EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control the target system Multi-channel support RTC with Data Storage RS485 Output Isolated Voltage Channel Alarming & Protection Onsite Programmable Load Profile Analysis Page 1 of 6

Block Diagram: Timekeeper for time stamping of values Display 4 line 8 digits LED display Applications: Solar Photovoltaic Systems Battery chargers and systems Wind Power Generation Measurement Inputs 1 channel Voltage Relay Outputs 4 RO Electroplating Industries Power Distribution for Telecommunication Industrial DC control Systems Modbus-RTU Measurement Inputs 4 channel Current Standard Optional Power Supply 60-300 V AC/DC USB-based Serial Port Possible applications of Relay Outputs: Alarming via lamp or horn Load shedding Remote controlling Product Features: Multi-Channel Support: Single meter measures energy consumption of four independent loads connected to one Voltage source Bi-Directional Voltage & Current measurement: The meter has a unique feature of measuring both charging and discharging current Isolated Voltage Channel (optional): The Voltage channel is galvanically isolated from rest of the circuitry Event Logging: Previous 5 Events of factory-default parameters can be logged with Date and Time stamp Data Logging: User Selectable parameters (1 to 30) can be logged at regular intervals (1 to 60 min) with Date & Time stamp in internal memory and can be accessed via Modbus Max Records can vary from 8532 to 91010 depending upon number of selected parameters Load Profile Analysis: Logging of Energy consumed and Peak Demand (Power & Current) in a day and in a month for efficient tracking of load behaviour Daily Data is available for last 1 year and Monthly Data is available for last 14 years Direct Remote Access (optional): Remote configuration of the Instrument and access of measured parameters via MODBUS Programmable baud rates up to 57.6kbps 4 - line 8 digit Ultra-bright LED Display: 4 - line LED display provides easily readable data on meter front with a display range of 99999999 Reverse Locking: Energy and Ampere Hour accumulation can be blocked for Reverse Power and Current resp. Reverse condition can be set as Import or Export Onsite Configuration: Configuration can be done via Front Keys, USB-based Serial Interface or RS485 (MODBUS) Relay Functions: Limit Switch - For protection against over-shoot or under-shoot of any selected parameter Pulse Output - To drive an external counter for energy measurement Timer - Cyclic ON-OFF operation of relay for user-defined cycles with programmable ON-OFF Delays Remote Operation - Relays can be activated remotely via Modbus Reverse Locking Alarm RTC Relay - Relay can be activated & deactivated at predefined ON & OFF Time on any or all Days of Week Enclosure Protection for dust and water: Conforms to IP 54 (front face) as per IEC60529 Compliance to International Safety standards: Compliance to International Safety standard IEC 61010-1 - 2010 EMC Compatibility: Compliance to International standard IEC 61326-2012 Page 2 of 6

96mm 92mm+0.8 RISH EM DC Dimensions Details: 96 mm Display Area Front View 3.15 80mm Side View 92mm+0.8 Panel Cutout Technical Specifications: Input Voltage: Nominal Input Voltage Range Max continuous input voltage Input Current: No of Channels 4 Current Sensor Shunt Setting Range Full Scale Setting Range Max continuous input current Operating Measuring Range: Voltage Current Auxiliary Supply: Higher Aux Nominal Value VA Burden: Nominal input voltage burden Nominal input current burden Auxiliary Supply burden Accuracy: Relay Output: Max Load Voltage Max Load Current 10 ~ 60 VDC 61 ~ 200 VDC 201 ~ 1000 VDC 125% of nominal value External Shunt 1 A to 20 ka 125% of nominal value 60 V 300 V AC-DC, 45 to 65 Hz range < 0.4 W approx. < 0.1 W approx. per channel < 6 VA approx Reference Conditions 23 C +/- 2 C Voltage ±0.5% of Nominal value (±5 to ±120%) Current ±0.5% of Nominal value (±5 to ±120%) Power ±0.5% of Nominal value (±5 to ±120%) Energy Class 1 Temperature Drift Display: Type Display Height Overload Indication Display Range: 50 ~ 150 mv 0.1%/ C 4 line 8-digit LED Display 9 mm Voltage 0 to ±9999 Current 0 to ±9999 Power 0 to ±9999 Energy (Import & Export) 0 to 99999999 Real Time Clock (RTC): Uncertainty ±2 to ±125% of nominal value ±0.2 to ±125% of nominal value 230 V AC-DC, 50/60 Hz for AC Aux -ol- (Above 126% of nominal value) 250 VAC / 30 VDC 5 A ±2 minutes / month (23 C +/- 2 C) NOTE: Variation due to influence Quantity is 100% of class index Page 3 of 6

Installation: Meter PANEL SLIDE IN THIS DIRECTION AND LOCK Electrical Connection: Vdc- Vdc+ Aux Supply Technical Specifications: Optional RS485 Communication: Protocol Baud rate Distance Overload Withstand: Voltage Current Applicable Standards: Modbus-RTU 4800, 9600, 19200, 38400, 57600 bps 1200 m EMC IEC 61326-2012 Immunity Safety IP for water & dust IEC 60529 (IP 54) Pollution degree 2 Installation category Protective Class 2 High Voltage Test (DC, 1 minute) (Optional) 2 x rated value for 1 second, repeated 10 times at 10 second intervals 20x rated value for 1 second, repeated 5 times at 5 min intervals IEC 61000-4-3. 10V/m min Level 3 industrial Low level IEC 61010-1-2010, Permanently connected use 1000V CATII, 600V CATIII (Measuring Inputs) 300V CATIII (Power Supply) 6.22 kv DC, Enclosure versus all electrical circuits 5.23 kv DC, Auxiliary Supply versus all other electrical circuits 3.11 kv DC, Measuring Terminals versus all other electrical circuits 3.11 kv DC, Relay versus Relay 3.11 kv DC, USB & RS485 versus all other electrical circuits 3.11 kv DC, Voltage versus Current Shunt LOAD 1 LOAD 2 LOAD 3 LOAD 4 2 5 8 11 1 3 4 6 7 9 V+ V- I1+ I1- I2+ I2- I3+ I3- I4+ I4-13 14 L N Environmental: Operating temperature -10 to +55 C Storage temperature -20 to +70 C Relative humidity 0... 90% non condensing Warm up time Minimum 3 minute Shock 15g in 3 planes Vibration 10... 55...10 Hz, 0.15mm amplitude Number of Sweep Cycles 10 per axis Dimensions & Weights : Bezel Size 96 mm x 96 mm DIN 43 718 Panel Cut-out 92 + 0.8 mm x 92 + 0.8 mm Overall Depth 80 mm Weight 620 gm. approx. It is recommended that the wires used for connections to the instrument should have lugs soldered at the end. That is, the connections should be made with Lugged wires for secure connections. The Maximum diameter of the lug should be 7.0 mm and maximum thickness 3.5mm. Permissible cross section of the connections wires: <= 4.0 mm sqr. single wire or 2x2.5mm sqr. fine wire Page 4 of 6

Measured Parameters: Sr No Parameters Sr No Parameters 1 Voltage 2 Current channel 1 3 Current channel 2 4 Current channel 3 5 Current channel 4 6 Total Import & Export Power 7 Power channel 1 8 Power channel 2 9 Power channel 3 10 Power channel 4 11 Total Import & Export Energy 12 Import and Export Energy channel 1 13 Import and Export Energy channel 2 14 Import and Export Energy channel 3 15 Import and Export Energy channel 4 16 Total Import & Export Ampere Hour 17 Import and Export Ampere Hour channel 1 18 Import and Export Ampere Hour channel 2 19 Import and Export Ampere Hour channel 3 20 Import and Export Ampere Hour channel 4 21 Total Import & Export Power Demand 22 Import and Export Power Demand channel 1 23 Import and Export Power Demand channel 2 24 Import and Export Power Demand channel 3 25 Import and Export Power Demand channel 4 26 27 28 29 30 Total Import & Export Current Demand Import and Export CurrentDemand channel 1 Import and Export CurrentDemand channel 2 Import and Export CurrentDemand channel 3 Import and Export CurrentDemand channel 4 31 On Hour 32 Run Hour channel 1 33 Run Hour channel 2 34 35 Run Hour channel 3 Run Hour channel 4 36 Max and Min Voltage 37 Max and Min Current channel 1 38 Max and Min Current channel 2 39 Max and Min Current channel 3 40 Max and Min Current channel 4 41 Max Import and Export Power Demand channel 1 42 Max Import and Export Power Demand channel 2 43 Max Import and Export Power Demand channel 3 44 Max Import and Export Power Demand channel 4 45 Max Import and Export Current Demand channel 1 46 Max Import and Export Current Demand channel 2 47 Max Import and Export Current Demand channel 3 48 Max Import and Export Current Demand channel 4 49 Number of Interrruptions 50 Old Import and Export Energy channel 1 51 Old Import and Export Energy channel 2 52 Old Import and Export Energy channel 3 53 Old Import and Export Energy channel 4 54 Old Import and Export Ampere Hour channel 1 55 56 57 58 Old Import and Export Ampere Hour channel 2 Old Import and Export Ampere Hour channel 3 Old Import and Export Ampere Hour channel 4 Old Max Import and Export Power Demand channel 1 59 Old Max Import and Export Power Demand channel 2 60 Old Max Import and Export Power Demand channel 3 61 62 Old Max Import and Export Power Demand channel 4 Old Max Import and Export Current Demand channel 1 63 Old Max Import and Export Current Demand channel 2 64 Old Max Import and Export Current Demand channel 3 65 Old Max Import and Export Current Demand channel 4 66 Old On Hour 67 Old Run Hour channel 1 68 Old Run Hour channel 2 69 Old Run Hour channel 3 70 Old Run Hour channel 4 71 Old Number of Interruptions Page 5 of 6

Ordering Information: Ordering information Model Basic Model (without USB, RTC & Datalogging) Higher Model (with USB, RTC & Datalogging) Ordering Code RISH EM DC 6001 6002 Nominal Input Voltage 10-60 V 61-200 V 201-1000 V Voltage Isolation With Isolated Voltage Channel With Non-Isolated Voltage Channel 60 200 1000 V NV Auxiliary Supply Voltage 60-300 V AC DC HA Communication MODBUS (RS485) MODBUS Option not used C NC Output Options No Relay Output 2 Relay Outputs 4 Relay Outputs NR 2R 4R Order Code Example: RISH EM DC - 6002-60 - V - HA - C - 2R RISH EM DC Higher Model, Voltage Range 10-60 V, with Isolated Voltage Channel, Higher external aux 60V 300V AC/DC, with MODBUS (RS485) communication, 2 relay outputs. Page 6 of 6