TX³ RCCBs 2P up to 100 A

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

DX³ RCCBs - ID 4P up to 100 A

R.C.B.O. SP / 1 module

up to 63 A (1 module per pole)

Phase + Neutral, neutral on left side

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DX³ 4-pole RCBO 6000 A/10 ka

Phase + Neutral, neutral on right side

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

(1,5 modules per pole)

DX³ RCBO 6000 A Phase + Neutral, neutral right side

RX 3 M.C.B A up to 63 A

RX 3 M.C.B A up to 63 A

DX³ RCBO 6000A Phase + Neutral, neutral on left

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DX³ RCBO 6000 / 10 ka Phase + Neutral, neutral on left

DX³ RCBO 6000A Phase + Neutral, neutral on right

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

Cat N 3. OVERALL DIMENSIONS

Btdin RCBO 6000A up to 63A (2P)

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

Industrial Contactors CTX 3 3P 185A - 800A

DPX Magnetic only

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX moulded case circuit breakers

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

COMPLETE SOLUTIONS FOR POWER PROTECTION

Low Voltage A GE Power Controls Company. General catalogue

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

Vistop TM isolating switches 63 to 160A

New DX 3 High rating & breaking capacity

NEW TX³ RANGE PROTECTION YOU CAN RELY ON

DPX earth leakage DPX 3 -I earth leakage

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

K50H004UP cam changeover switch - 4-pole A - screw mounting

DRX 250 B/N/H Circuit breaker (not adjustable)

DRX 100 B/N/H Circuit breaker (not adjustable)

AF40... AF96 3-pole contactors Technical data

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Multi 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

DPX 1600 Electronic release

cor Long Run Experience

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

DMX 3 -I 2500 switch disconnectors

K30H001YP cam star-delta switch - 3-pole A - screw mounting

K63F003UP cam changeover switch - 3-pole A - screw mounting

K50F003UP cam changeover switch - 3-pole A - screw mounting

Residual current devices

Contents. Acti 9 MCBs, RCCB. ic60h circuit breakers (curve B, C, D)... pages 2/2 to 2/4. ic60h and ic60h2 RCB0 10, 30 and 100 ma...

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Thermal magnetic and trip-free switches

MCBs and RCDs LR TM 6000

DRX 125 Circuit breaker (not adjustable)

DPX 630 Electronic release

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

DPX Electronic + earth leakage

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

D509E. Manual Motor - Starters

Modular contactors and relays

Protection components

3 - Protection components Motor circuit-breakers

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

NB1 Miniature Circuit Breaker

Domae. The right solution for distribution boards

Miniature Circuit Breaker

Viking 3 - Screw connection Disconnect terminal blocks

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

QUALITY ASSURANCE & DOCUMENTATION

W DATA SHEET: COMBINED FAULT-CURRENT PROTECTIVE SWITCH, SERIES BOLF, 3P+N

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

DSE201 Compact design with enhanced protection

Breaking and protection devices

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Electronic overload relay EF65, EF96 and EF146

Offers. QOvs RCBO residual current devices. Protection Earth leakage protection. Variants

RESIDUAL CURRENT CIRCUIT BREAKER

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V

Essential equipment for all your requirements

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

DS201 - DS202C New residual current circuit-breakers with overcurrent protection (RCBOs)

CABINETS AND ENCLOSURES. XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Thermal overload relay TF65 and TF96

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Short form catalogue. Motor protection & control

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

XB5AD33 SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Transcription:

87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s 0090 00/01/02/06/07/11/12/13/14 0/01/02/06/07/11/12/13/14/18/19/23/24/25/26/ /18/19/23/24/25/26/45/46 45/46 0090 48/49, 0091 40/41/42/43/46/47/48/49/58/59 43/46/47/48/49/58/59/ CONTENTS PAGES 1. Electrical and mechanical characteristics... 1 2. Installation... 4 3. Standards... 4 4. Environment... 4 5. Overall dimensions... 5 6. Marking... 5 7. Derating... 5 8. Association with upstream protection... 6 9. Residual current tripping curves... 7 Symbol : Technology :. Electromagnetic residual current operating by sensitive relay Product range :. Four pole - 4 module (4 x 17,8 mm). Version with neutral on right side Rated current : 25 / 32 / 40 / 63 / 80 A Sensitivity : 30 ma / 100 ma / 300 ma / 500 ma Type :. AC (residual sinusoidal alternating current). A (residual alternating current with a DC component). AC-S (selective). A-S (selective). AC-G (protected from unwanted trippings). A-Hpi (protected from unwanted trippings) Rated voltage / Frequency :. 400 V ~ - 50/60 Hz Insulation voltage :. Ui = 500 V Pollution degree :. 2 Rated residual breaking capacity :. I m = 1000 A according to EN/IEC 61008-1 Rated making and breaking capacity : According to EN/IEC 61008-1 In = 25 / 32 / 40 A : Im = 500 A In = 63 A : Im = 630 A In = 80 A : Im = 800 A Rated conditional short-circuit current :. Inc = 10 ka according to EN/IEC 61008-1 Rated conditional residual short-circuit current :. I c = 10 ka according to EN/IEC 61008-1 Ambient working temperature :. - 25 C / + 40 C Ambient storage temperature :. - 40 C / + 70 C Insulation against an impulse voltage :. Uimp = 6 kv Working positions : Operation at 400Hz :. Do not operate Dielectric strength :. 2000 V 50 Hz Insulation resistance :. 2 MΩ 1 / 8

Total dissipated power :. By device loaded at In I n 25 A 40 A 63 A 80 A 30 ma 25 and 40 A Type A and AC 11 W 24 W --------- - --------- - All others : 8.5 W 14.5 W 36.5 W 50 W Protection against unwanted tripping :. 0.5µs/100 khz ring wave : 200A. 8/20 µs surge current: - type A - AC : 250 A - type S, Hpi, G : 3000 A Mechanical and electrical endurance :. According to EN/IEC 61008-1 : - 20 000 operations without load - 10 000 operations with load (under In x Cos ϕ 0,9) - 1000 operations by test - 1000 operations by earth fault current Limit rated voltages for test operation triphase network with or without neutral :. Rated voltage for operation : 400 V 0090 48/49, 0091 40/41/42/43/46/47/48/49/58/59/ Closing and opening forces by handle operation :. 4.2 kg at closing (every rated currents). 1.3 kg at opening (every rated currents) Heat and fire resistance :. Self extinguishing (glow wire test) : Base, Top and Test : 960 C Handle : 750 C Average weight per item : 0.38 kg Volume and quantity when packed : For all rated currents Volume Packaging 0.7 dm3 par 1 I n type U mini U maxi 30 ma all 195 V * 440 V 100 ma all 230 V 440 V 300 ma A / AC 215 V 440 V 300 ma S 230 V 440 V 300 ma Hpi / G 190 V * 440 V 500 ma A / AC 295 V 440 V 500 ma S 230 V 440 V 500 ma Hpi / G 210 V 440 V * Operate in 230 V triphase network Protection degree :. Terminals protection against touching : IP20 (connected device). Front face protection against touching : IP40. Class II refered to metallic parts. Protection against shocks : IK04 Isolating distance (distance between contacts) :. Handle in open position (OFF) : - Neutral pole : over 4,5 mm - Phase pole : over 5,5 mm 2 / 8

0090 48/49, 0091 40/41/42/43/46/47/48/49/58/59/ Mains parts of R.C.C.B. : DIN rail clamp Terminals IN OUT Mecanism lock Plug-in Contacts Handle Test bottom Polarized relay with shield plate Core subassembly Terminals 3 / 8

2. INSTALLATION Fixing :. On symmetric rail EN 50.022 or DIN 35 Supply :. From the top or the bottom Connection :. Terminals with release type captive screw (feeder equipped preventing the insertion of a wire cable under the terminal, terminal half-opened or closed). Alignment and spacing of terminals allowing busbar connection with other products of the same range. Terminal depth : 14 mm. Terminal capacity : 60 mm². Max acceptable wire size : - 35 mm² flexible cables - 50 mm² rigid cables. Screw head : mixed, slotted and philips/pozidriv n 2 Tightening torque :. Minimum / Maximun : 1,2 Nm / 3,5 Nm. Recommended: 2,5 Nm Wire : Without ferrule With ferrule /02/06/07/11/12/13/14/18/19/23/24/25/26/45/46 0090 48/49, 0091 40/41/42/43/46/47/48/49/58/59/ 2. INSTALLATION installation software:. XL PRO Auxiliaries clipped ped on the left-hand side of the R.C.C.B. s Auxiliaries list : Signalisation auxiliaries:. Auxiliary changeover switch (ref. 073 50) (0,5 module). Fault signalling changeover switch (ref. 073 51) (0,5 module). Auxiliary changeover switch, can be modified to a fault signalling switch (ref. 073 53) (0,5 module). Auxiliary changeover switch + fault signalling switch, can be modified to 2 auxiliary changeover switches (ref. 073 54) (1 module) Control auxiliaries :. Shunt trip (ref. 073 60/61) (1 module). Undervoltage release (ref. 073 65/66/68) (1 module) Possible combinations of auxiliaries and R.C.C.B. s : Maximum number of auxiliaries = 3.. Maximum number of 0.5 module auxiliary = 1. Maximum number of signalling auxiliaries = 2. Maximum number of control auxiliaries = 1. Control auxiliary must be positioned on the left-hand side of signalling auxiliaries in case of use of these two kinds of auxiliaries with the same R.C.C.B. Rigid cables Flexible cables 1 x 0,75 à 50 mm² ou 2 x 0,75 à 16 mm² 1 x 0,75 à 35 mm² ou 1 x 0,75 à 25 mm² 3. STANDARDS Compliance with standards :. NF EN 61008-1 / IEC 61008-1. EN/IEC 60 529 (IP). EN 50 102 (IK) 4. RESPECT OF ENVIRONMENT 2 x 0,75 à 16 mm² Wiring accessories :. Supply busbar (réf. 049 44/45). Terminal screw covers (réf. 044 44). Lexiclic line distributor (réf. 37 316/317) + wires Tools required :. For terminals : - 5,5 mm or pozidriv n 2 screwdriver recommended. For fixing : - 5,5 mm recommended screwdriver Sealing :. Possible in open or closed position Locking :. Possible with support for padlock (ref. 044 42) Marking :. Circuits marking on front (with label holder). With label design software. With electronic title printer + ribbon. With plates of symbols Compliance with European Union Rules :. Conformity with directive 2002/95/CE of 27/01/03 called «RoHS» that provides interdiction of dangerous material like lead, mercury, cadnium, hexavalent chrome, retarding of polybromobiphenyles (PBB) and polybromodiphnylethers (PBDE) bromed flame from july 2006 the 1st.. Conformity with directive 91/338/CEE of 18/06/91 and decree 94-647 of 27/07/94. Plastic material :. Enclosure plastic parts without halogen : - Base, Top and Test : PA 6 - Handle : PBT. Plastic parts marking according to ISO 11469 and ISO 1043 Packaging :. Packing design and manufacture according to decree 98-638 of 20/07/98 and directive 94/62/CE 4 / 8

0090 48/49, 0091 40/41/42/43/46/47/48/49/58/59/ 8/49/58/59/ 5. OVERALL DIMENSIONS 70mm 44mm 93mm 83mm 45mm 71.2mm 60mm 76mm 6. MARKING Front face marking : by permanent pad printing. T 3 5 N 4 6 N Im =5 00A I m =1000A 400 V 10000 I n=0,03 A TEST 30mA Fréquent Frequently 5 / 8

8. ASSOCIATION WITH UPSTREAM PROTECTION Protection against overloads :. R.C.C.B. must be protected (upstream or downstream) against overloads by a m.c.b. or a fuse at maximum with the same rate. 0090 48/49, 0091 40/41/42/43/46/47/48/49/58/59/ 8. ASSOCIATION WITH UPSTREAM PROTECTION Protection against short-circuits :. R.C.C.B. must be protected (upstream) against short-circuits by a m.c.b. or u fuse according to the hereunder tables.. 400/415 V three phases + neutral network : Maximum value of short-circuit withstand of R.C.C.B. s in terms of associated protection downstream R.C.C.B upstream M.C.B. DX DX-h DX-L DPX 125 25 A 10 ka 20 ka 50 ka 25 ka 32 / 40 A 10 ka 15 ka 50 ka 25 ka 63 A 10 ka 12.5 ka 50 ka 25 ka 80 A 10 ka 12.5 ka 50 ka 25 ka downstream R.C.C.B upstream gg FUSE Rated current 25 A 40 A 63 A 80 A 25 A 100 ka 100 ka 50 ka 15 ka 32 / 40 A 100 ka 100 ka 50 ka 15 ka 63 A 100 ka 100 ka 50 ka 15 ka 80 A 100 ka 100 ka 50 ka 15 ka 6 / 8

0090 48/49, 0091 40/41/42/43/46/47/48/49/58/59/ 66/67/71/72/73/77/78/79, /78/79, 6021 08/09/10/18, 9. RESIDUAL CURRENT TRIPPING CURVES Curve of tripping time in terms of residual current TYPE AC 1 T (s) 0.5 30 ma 100 0 ma 300 ma 500 0 ma 0.1 0.05 Type S Type G Type Standard 0.01 10 0 10 1 10 2 10 3 I (ma) 10 4 7 / 8

0090 48/49, 0091 40/41/42/43/46/47/48/49/58/59/ 9. RESIDUAL CURRENT TRIPPING CURVES Curve of tripping time in terms of residual current TYPE A 1 T (s) 0.5 100 0 ma 300 ma 500 0 ma 0.1 30 ma 0.05 Type S Type Hpi Type Standard 0.01 10 0 10 1 10 2 10 3 I (ma) 10 4 8 / 8