FUME HOOD SELECTION GUIDE

Similar documents
General Purpose Walk-In Fume Hood

General Purpose Walk-In Fume Hood

new fume hoods providing performance and protection

Fume Hoods Overview OVERVIEW

F. VAV hoods shall have a restricted bypass plate.

Requires Ductwork and Blower

Protector XStream Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector

Supreme AirLV- FUME HOODS. KEWAUNEE encouraging new discovery LOW CONSTANT VOLUME

Protector XStream Laboratory Hoods

LABORATORY FUME HOODS

LABORATORY FUME HOODS OF 5

BMC. Laboratory Fume Hoods SEFA SCIENTIFIC EQUIPMENT & FURNITURE ASSOCIATION M E M B E R

RDM. Laboratory Fume Hoods SEFA SCIENTIFIC EQUIPMENT & FURNITURE ASSOCIATION

th Avenue Spring Lake, MI Ph:

V05 General Purpose Bench Fume Hood

Fume hood construction details. VANGUARD FUME HOODS Listed by Intertek to UL 1805 standard page 1. Features

LABORATORY FUME HOODS

Section Fume Hoods Specifications 6/1/14 LABORATORY FUME HOODS

Fume hood construction details VANGUARD FUME HOODS. Listed by Intertek to UL 1805 standard. page 1. Features

Laboratory Demonstration Space Located at Price Research Center North Winnipeg. Fume Hoods. ehpricesales.com

Thermo Scientific Hamilton Air Flow Products. Table of Contents

CORPORATION DURALAB CORPORA

Supreme Air. Fume Hoods KEWAUNEE LABORATORY. encouraging new discovery

.1 Special Building Areas 8. Laboratories..3 Laboratory Casework (section ).4 Chemical storage cabinets (section )

SECTION LABORATORY FUME HOODS UNIFLOW LE SERIES

DetectAir KEWAUNEE FILTERED FUME HOODS. encouraging new discovery

Protector Special Application Hoods Laboratory Hoods for Radioisotope, Perchloric Acid and Acid Digestion Use Fiberglass 28, Demonstration and Canopy

Protector XL Floor-Mounted Laboratory Hoods Features & Benefits

Laboratory Fume Hoods & Enclosures

HEMCO. Laboratory Fume HoodsR

LABORATORY CABINETRY AND SPECIALTIES: FUME HOODS

AUDIO-VISUAL EQUIPMENT

SECTION LABORATORY FUME HOODS

Supreme Air Fume Hood Option Availability

Bedcolab Vanguard Laboratory Fume Hoods

AUDIO-VISUAL EQUIPMENT

Accessories Standard Service Fixture Kits

Protector Airo Filtered Fume Hoods

Protector Demonstration Hoods

January, 2014 Page 1 of 6

Polypropylene Total Exhaust Fume Hoods

Quotations are invited for Fume Hoods for Chemistry Laboratory Pre Qualification Criteria

Lab Safety & Energy Optimization. Introduction & Agenda

Fume Hood Program. Program originated: 08/2008 Updated: 06/2016. Gordon Krueger Environmental Safety Specialist

User s Manual. LabShield. Laboratory Fume Hoods. Air Foil By-Pass Models: 6714, 6716, ADA Models: 8796, 8798, Demonstration Hood 6725G

DEPAUL UNIVERSITY. Fume Hoods Manual. Environmental Health & Safety. April 2017

Protector. Storage Cabinets, Base Stands & Fume Hood Accessories

High Performance Ductless Balance Enclosures

Completing Your Fume Removal System

Fume cupboards and extraction devices

The Green Solution Hood (Chemical Filtration) 2. Eliminator HP Series High Performance Energy Efficient Hood 6

PERCHLORIC ACID FUME HOOD H25. Fume Hoods. 48"- 60"- 72"- 96" long

Ductless Nanoparticle Containment Enclosures

Laboratory Fume Hoods & Enclosures

Laboratory Fume Hood. Operation & Maintenance Manual APR 2005

Annexure-1. Annexure- 1 TECHNICAL SPECIFICATIONS FOR THE MODULAR LABORATORY FURNITURE (CNSNT/RL-4)

How to Use a Chemical Fume Hood Safely

Ductless mobile fume hoods with modular filtration column

Design Requirements The system shall be designed, manufactured, tested and installed in compliance with the current versions or issuance of:

Ductless Nanoparticle Containment Enclosures

Ductless Nanoparticle Containment Enclosures

Fume Hood Standard. The appropriate maintenance/engineering division on each campus or other business unit operating on UofT property shall:

General Application Ductless Fume Hoods

Protector. Storage Cabinets, Base Stands & Fume Hood Accessories

Supreme Air Venturi KEWAUNEE. Laboratory Fume Hoods. encouraging new discovery...worldwide

HEMCOR ISO 9001:2008 Certified Company

Design Standard - Fume Hoods & Fume Hood Exhausts

Protector Echo Filtered Fume Hoods

LFBC - LATERAL FLOW BIO CONTAINMENT FOR HPAPI PROCESSING FLOW SCIENCES, INC.

Element D Services Heating Ventilating and Air Conditioning ODG010107

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

Modified Downdraft Paint Booth Nut and Bolt Assembly Pre-Punched Panel Flanges

DESIGN STANDARDS WASHINGTON UNIVERSITY SCHOOL OF MEDICINE

Laboratory Fume Hoods

Refrigerators/Freezers

3.5 Exposure Control Measures

Labconco 48, 60, and 72 Hoods

Thermo Scientific 1300 Series A2. Class II, Type A2 Biological Safety Cabinets. Good for you good for the environment

Fume Hood Operation & Maintenance Manual

REDISHIP Biosafety Cabinets, Fume Hoods and Balance Enclosures

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Element D Services Heating, Ventilating, and Air Conditioning

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

Frontier. Laboratory Fume Hood. Perfectly tailored solutions for your fume containment needs

Ventilated Balance Enclosures

Global Finishing Solutions Table of Contents

Element D Services Heating, Ventilating, and Air Conditioning

Automatic Cyanoacrylate Fuming Chamber XL. Safely Obtain Quality Latent Prints and Reproducible Results

biolus BIO SAFETY CABINET

STATE UNIVERSITY CONSTRUCTION FUND

Laboratory Fume Hood

Supreme Air Venturi Laboratory Fume Hood Catalog. ehpricesales.com

INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD

Thermo Scientific Hamilton Horizon Fume Hoods. Operation, Maintenance and Installation Instructions

Series. Ductless Fume Hoods The Safe, Energy Efficient Solution for Modern Chemistry

Series 301. Horizontal Laminar Flow Clean Bench. C l e a n B e n c h e s. s o l u t i o n s. Series 301 Horizontal Laminar Flow Clean Bench

Compounding Safety Solutions.

Alpha System ADAPTABLE KEWAUNEE LABORATORY FURNITURE. encouraging new discovery

INSTALLATION INSTRUCTIONS K SERIES LINER INSERT

Laboratory Carts & Benches

Transcription:

FUME HOOD SELECTION GUIDE

FUME HOOD SELECTION GUIDE Laboratory fume hoods are one of the most vital pieces of safety equipment in a working laboratory. Fume hoods are designed to safely exhaust dangerous fumes, unpleasant odors, vapors, and particulates away from the user and safely out of the building. This guide will help you safely select the best fume hood for your particular application. Why Genie? ChemTough The most durable general purpose fume hood liner on the market comes as the standard option on Genie hoods. PowerLink Robust chain and sprocket sash counter balance system that will never fail, we guarantee it! SlideSafe Horizontal sliding doors that hang from a heavy duty ibeam via rugged jump proof carriers for enhanced ease of use and safety. No more worrying about broken or gunked-up lower track wheels. SpillSafe Fume hood work surfaces are dished to safely contain spills inside the hood. AirDirect Bench top and distillation hoods are fitted with an aerodynamic airfoil to direct air across the work surface ensuring floor sweep for safe operation. DirectConnect All our hoods are fitted with a simple round exhaust collar for connection to building HVAC. No complicated or expensive ductwork transition pieces needed, just a simple round connection UL Listed Genie hoods are UL 1805 Listed SEFA Member Member of the Scientific Equipment and Furniture Association California OSHA As a CA company our hoods meet and exceed all CAL/OSHA 5154.1. Ventilation requirements for laboratory fume hoods. ASHRAE 110 Tested Our hoods are ASHRAE 110 tested Important: Fume hoods only function safely when connected to a properly engineered and balanced HVAC system and building utility services. Failure to verify compatibility with your building can result in an unsafe system. Consult the proper trade professionals and a Genie fume hood expert with questions.

where you ll find it Step 1: Determine Needed Interior Working Dimensions 2 Standard Fume Hood Sizes 3 Step 2: Select Fume Hood Type 4 Step 2A: Any Special Purpose Requirements? 4 Step 3: Select Sash Style 5 Bench Top Sash Options 5 Walk-In and Distillation Sash Options 6 Step 4: Select Interior Liner Material 7 Step 5: Identif y Air Flow Requirements, Exhaust and Bypass Type 8 Sash Operating Positions 8 Exhaust System and Fume Hood Bypass Type 9 Step 6: Select Accessories 10 6A: Base Units 10 6B: Plumbing 10 6C: Electrical 10 6D: Specialty Accessories 10 6E: Exhaust Blowers 10

2 INTERIOR WORKING DIMENSIONS STEP 1 DETERMINE NEEDED INTERIOR WORKING DIMENSIONS Based on the chemistry, apparatus, equipment and required interior working dimensions Genie will help you select the proper fume hood. All Genie hoods come in several standard widths and depths. If a standard size does not fit your needs we can easily customize to meet your requirements. Building custom fume hoods is our specialty. What are your needed interior working dimensions? D" B" C" A = interior width B = interior depth A" C = interior height D = max opening height for setup

STANDARD FUME HOOD SIZES 3 A" C" BENCH TOP HOODS* width depth A B C D B" 28" Full Open 47" D" 54 1/2" 36 27 32.5 24 48 39 38.5 30 60 51 44.5 36 72 63 96 87 120 111 elevation view bench top fume hood section view *Based on PowerLink Vertical Rising Sash. Different sash type will affect interior dimensions. A" C" WALK-IN HOODS (Floor Mounted) width depth A B C D 48 18.25 33.5 24 60 25.25 39.5 30 72" Full Open B" 72" 89" 95" 72 30.25 44.5 36 96 39.25 57.5 48 120 51.25 144 61.25 elevation view walk-in fume hood D" section view *Based on SlideSafe horizontal doors on two tracks. 48 72 Hoos have (2) doors, 96 144 have (4) doors. Different sash type will affect interior dimensions. A" C" DISTILATION HOODS* width depth A B C D 57" Full Open 77" 69" 77" 48 39 36 24 60 51 42 30 72 63 48 36 B" D" 96 87 60 48 120 111 *Based on (2) vertical rising PowerLink Sashes. Different sash type will affect interior dimensions. elevation view distilation fume hood section view DON T SEE WHAT YOU NEED? GIVE US A CALL.

4 FUME HOOD TYPES STEP 2 SELECT FUME HOOD TYPE BENCH TOP FUME HOOD Mounts on SpillSafe top and base unit(s), most commonly cabinets. WALK-IN FUME HOOD (Floor Mounted) Sits directly on the floor Designed for large apparatus set ups and roll in equipment Building extra-large walk-in hoods in a specialty of Genie DISTILLATION FUME HOOD Mounts on SpillSafe top & low height base unit(s) Extra interior height to accommodate tall apparatus, most commonly distillation racks STEP 2A ANY SPECIAL PURPOSE REQUIREMENTS? ADA Compatible Pass-Thru (Double Sided Hood)

BENCH TOP SASH OPTIONS 5 STEP 3 SELECT SASH STYLE VERTICAL RISING SASH Driven by PowerLink Frameless piece of laminated safety glass that moves up and down Most common sash type HORIZONTAL SASH Panes of laminated safety glass that move left and right in a track Contact Genie for # of panes per hood COMBINATION SASH Driven by PowerLink Consists of a framed vertical rising sash that also has horizontal sliding panes of safety glass SPLIT SASH Driven by PowerLink Two framed safety glass sashes that can move up and down independently of each other with a disappearing center post

6 WALK-IN / DISTILLATION SASH OPTIONS STEP 3 CONTINUED SELECT SASH STYLE SLIDESAFE HORIZONTAL SASH Horizontal sliding doors that hang from a heavy duty ibeam via rugged jump-proof carriers VERTICAL RISING SASH Driven by PowerLink Dual framed pieces of laminated safety glass that move up and down Allows for threshold free access COMBINATION SASH Driven by PowerLink Consists of dual framed vertical rising sash that also have horizontal sliding panes of safety glass

INTERIOR LINER MATERIAL 7 STEP 4 SELECT INTERIOR LINER MATERIAL The fume hood exterior (powder coated) and superstructure (galvanized) are made from steel. The interior is lined with a specialty material selected to withstand your chemistry. Liner Material Advantages Disadvantages ChemTough Standard Genie liner Bright White, 0.25 thick Phenolic Resin Superior general purpose liner High chemical resistance to broad range of chemicals Fire Rated Excellent Structural strength Stainless Steel T304/T316 #4 Finish, 18ga High tolerance to flames & heat Easy to clean and sterilize Subject to attack by some chemicals Polypropylene White, 0.25 thick Superior resistance to corrosives Poor tolerance to flames & heat Other liner options available. Speak with a Genie fume hood expert for more information.

8 AIR FLOW STEP 5 IDENTIFY AIR FLOW REQUIREMENTS, EXHAUST AND BYPASS TYPE Fume hoods have two distinct sash operating positions. This ensures better protection of users and helps reduce the amount of supply air needed from your HVAC system. SASH OPERATING POSITIONS 1. FULL OPEN SETUP POSITION: The max opening of the sash to allow for loading and setup of the experiment. It is very important to double check your required full open dimensions, particularly when selecting walk-in and distillation hoods. You want to ensure you can get the intended items into the fume hood. The experiment should never be performed in the full open setup position! 2. OPERATING POSITION: Position of the sash while the experiment is being performed. As a California company Genie adheres to the CAL-OHSA standard of 100FPM face velocity calculated at the sash operating position. SETUP OPERATING 28" 18" 28" Full Open 18" Operating Position

STEEL LAB FURNITURE 9 EXHAUST SYSTEM AND FUME HOOD BYPASS TYPE Open Bypass-Constant Volume Exhaust System A constant volume exhaust system will exhaust the same amount of air (CFM) regardless of the sash position. An open bypass is used to divert air from the face opening when the sash is lowered to help limit variation to the face velocity. This is the most common type of exhaust system. Open bypass SASH OPEN SASH CLOSED Restricted Bypass-Variable Air Volume (VAV) Exhaust System A VAV is an exhaust system that typically maintains constant fume hood face velocity by adjusting blower motor speeds and duct dampers in response to changes in sash position. Normally only used with a multitude of fume hoods. The hood bypass is restricted to limit air entering the unit. Bypass is closed w/restricted panel SASH OPEN SASH CLOSED

10 SELECT ACCESSORIES STEP 6A BASE UNITS (Bench and Distillation Only) Standard Cabinets Corrosive Storage (ACID/BASES) Flammable Solvent Storage Vacuum Pump Cabinets Table Stand ADA Height Cabinets and Tables STEP 6B PLUMBING Remote Plumbing Service Fixtures Sinks STEP 6C ELECTRICAL 120v GFI Duplex* Light Switch* Blower Switch* Vapor Proof T8 Fluorescent light fixture* Airflow Alarm Analog* Digital Explosion Proof Fixtures for Class 1 Division 1 Environments Additional voltage outlets STEP 6D SPECIALTY ACCESSORIES Secondary containment trays Cord Ports Ceiling Enclosure Panel Distillation Racks Sash stops STEP 6E EXHAUST BLOWERS Genie can specify and provide the correct exhaust fan for your fume hood, along with accessories like exhaust stacks. WHITE WHITE wh121 GRAY BLUE ral5008 SILK GRAY ral7044 PURPLE RED 3004 ANTIQUE WHITE wh16 PASTEL BLUE 5024 LIGHT GRAY gr230 TEXTURE SILVER gr673 BEIGE bg02 BRILLIANT BLUE 5007 LIGHT GUNMETAL gr10 SEMI GLOSS BLACK bk05 *Standard Electrical package on Genie hoods *The standard colors above are a representation only; color may vary slightly from finished product. Powder coated steel samples are available upon request. Genie Scientific, Inc. 800.545.8816 p 714.545.1838 f 714.641.0496 17430 Mt. Cliffwood Circle, Fountain Valley, CA 92708 www.geniescientific.com MADE IN THE USA