M SERIES TECHNICAL DATA INFORMATION PACKET

Similar documents
D SERIES TECHNICAL DATA INFORMATION PACKET

D SERIES TECHNICAL DATA INFORMATION PACKET

S1 SERIES TECHNICAL DATA INFORMATION PACKET

PROFIRE E SERIES TECHNICAL DATA INFORMATION PACKET

PROFIRE V SERIES TECHNICAL DATA INFORMATION PACKET

Product Information. Model: LNVG, LNVLG Burner Sizes: 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

D SERIES BURNERS 4.2 TO 42.0 MMBTU/HR

PROFIRE. 4.2 TO 42.0 mmbtu/hr High-efficiency burner technology for the most stringent emissions requirements.

PROFIRE TO 92.4 mmbtu/hr High turndown burner for large firetube and watertube applications.

Power Flame Incorporated

M/SERIES. Installation, Operation, Service, and Parts Manual

XL/LNXL SERIES. Installation, Operation, and Service Manual for Vertical Configuration

FD68 BURNERS SELECTION GUIDE & ENGINEERING SPECS

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE

D/LND SERIES. Installation, Operation, and Service Manual

IMMERSION FIRED HOT WATER BOILER

GAS BURNERS TYPE JR Forced Draft Burners 3450 RPM motor and squirrel cage blower Leakage test, pilot and main gas cocks Gas electric pilot and gas ign

COMBUSTION. Model HDR - RF. Manual Addendum. (To be used in conjunctin with HORS-RF Manual) For Gas, Oil and Combination burners

FD68 Series Axial-Flow Packaged Burners MODELS: FD68 / FD68-LN / FD68-RF SIZE RANGE: 50-1,500 HP

MULTIFIRE. High temperature dual fuel burner

Model CBEX Elite HP

Eclipse Vortometric Burners Series HI

420-19,100 MBH GPH MODEL ACO/ACGO GAS AIR OR STEAM LIGHT OIL ATOMIZING FORCED DRAFT BURNERS

X4 Installation and Operation Manual - POWER FLAME INCORPORATED

1630 SERIES CYCLOPS TM ULTRA 4 LOW NOX TM HOT AIR BAFFLE BURNER

Manual C888 Rev.709 Copyright Power Flame Incorporated 2004 Printed U.S.A.

Economite RE Series. Power Gas Burners. MADE in the USA

Model HDS and HDSX Burner

VALUPAK. Packaged gas burners

1466 SERIES COLD AIR GAS/OIL BURNER

Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility

BOILER RATINGS. Net Ratings Oil Gas

Table Of Contents. Profire M Burner. Gas, #2-5 Oil, #2-6 Oil, or Combination. Installation Operation Maintenance Parts

KINEMAX. Medium velocity gas or oil burners

1470 SERIES HOT AIR GAS BURNER

Start-up Instructions

Info 110 4/98. RatioMatic Burners. RM Series version through 600 Sizes. 750 through 2000 Sizes

ICEMINI & Vertical MTI Units

Design and Application Details

779PAC TO 786PAC PROPORTIONING COMBINATION BURNERS

7. SERVICING AND COMPONENT ADJUSTMENTS

MODEL IFG INDIRECT FIRED MAKE-UP AIR HEATER

VALUPAK. Packaged gas burners


Packaged Gas Burner. Low CO and NOx emissions. Direct spark ignition. Factory pre-set for ease of start-up and operation

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models)

1200 SERIES FTR HOT AIR BAFFLE BURNER

Design and Application Details

OPEN FIRED STARJET BASIC UNIT SJ075 SJ260

Burner Capacity Information, BBC 1110/2110. Burner Capacity Information, BBC 3110

1032 SERIES LARGE CAPACITY DUAL FUEL OIL/GAS, AMBIENT OR PREHEATED AIR BURNER

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

Specifications of OPTIMA SLS Burners

Low emissions, high performance natural gas burners

1070 SERIES ULTRA LOW NO X

Features Enclosed Burner. Enclosed Burner. No visible flame. Controlled Combustion environment with natural draft design

Direct Gas-Fired Heating

02. Purpose : Heating / Drying / Calcination etc. 04. Feeder System : 0.5 H.P. Motorized Screw Feeder with VFD.

Specifications of MAXON VALUPAK burners for 50 Hz operation

97311T. Features T Enclosed Burner with Touch Screen Control Panel. No visible flame. Touch Screen Control Panel

Doing more for clean environment and energy saving

Surefire II TM Pilot Forced Draught Gas Pilot type SP-32-NG/PG-FD Instruction Manual

Model 4WI HP 4 Pass Wet-Back with Integral Burner

Table of Contents GF801U Series

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. )

MP GS/GD. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)

Design and Application Details

TROUBLESHOOTING. 1. What is the model and serial number? If you don t know, how old is it? Give description.

Applies to: Models F, B, FE, and BE with spark pilot

Power Flame Incorporated

Fig Blast tube 2.Asbestos gasket 3.Flange 4.Body gasket 5. Brake plate. 6. Oil n ozzle 7.Heater 8.Rubber block 9. Transformer 10.

Model CBLE Boilers HP

HEAVY DUTY RANGES GRIDDLE TOP

BBC Multi-fuel Combination Beta Burner

CLEAVER-BROOKS. ProFire Burner. Operation, Maintenance, and Parts Manual. Addendum to:

SureFire II TM Natural Draught Gas Pilot type SP-48-NG/PG-ND Instruction Manual

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

HVAC INDOOR MAKE-UP AIR HANDLERS

North American 4575 HiRAM

CATALOG OF REPLACEMENT PARTS

Date: Project #: Engineer: Prepared By: Bid Date:

SureFire II TM Pilot Forced Draught. Gas pilot type SP-32-xx-FD. Instruction Manual 1. INTRODUCTION 2. OPERATION PRINCIPLE AND TECHNICAL SPECIFICATION

Rheem Classic Plus Series Downflow Gas Furnace

2.0 Burner Operating Parameters and Requirements

DESCRIPTION SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DBUC/DBHB NOMINAL TONS 8.5 EER

100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Eclipse RatioAir Burners

product WM 10 oil, gas and dual fuel version Weishaupt monarch WM10 burners flexible application Information on oil, gas and dual fuel burners

TriOx Triple Air Staged Ultra Low NOx Burner

NON PRESSURIZED, GALVANIZED PREP ROOM Model #ENCG C-PREP

TGIF-3. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16

1500 SERIES LARGE CAPACITY ULTRA 2 LOW NO X

Oil, Gas and Dual Fuel Burners

North American Automatic Manual Reset and Motorized Valves

Replacement Parts List. Knight Fire Tube Boilers KHB 055 thru 285 Series 100 & _ _Rev B

BURNER SERVICE MANUAL 37

INDUSTRIAL MICRODIFFUSION DUAL-FUEL BURNERS

UPFLOW/ HORIZONTAL GAS FURNACE

Transcription:

M SERIES TECHNICAL DATA INFORMATION PACKET

Table of Contents Uncontrolled Emissions MG, MM#2, MMG#2 Technical Data Sheet... Ratings Table...4 Dimensions Table...5 Uncontrolled Emissions MM, MMG Technical Data Sheet...6 Ratings Table...7 Dimensions Table...8 Uncontrolled Emissions ME, MEG Technical Data Sheet...9 Ratings Table...10 Dimensions Table...11

Technical Data Uncontrolled Emissions Configuration (MG, MM#2, MMG#2) 1.4-10.5 MM BTU/H NG; 10-75 GPH #2 OIL UL listed with choice of NFPA, CSD-1, GAP, and FM for U.S. or Canadian units Standard equipment: 450 RPM motor, panel signal lights (Power On, Main Fuel, Ignition, Flame Failure), dry oven and gasket, combustion air proving switch, high fire air proving switch, 120/1/60 control circuit, burner mounted panel, hinged blast tube with right-hand swing. Gas and gas/oil units only: shipped loose gas train. Combustion Control System options: Parallel Positioning Combustion Control System with O 2 Trim and Variable Frequency Drive (VFD) Fuel options: Main Fuel: Natural gas (MG), #2 oil - air atomized (MM#2) or Combination gas/ #2 oil - air atomized (MMG#2). Igniter Fuel: Natural gas and/or propane. Fuel Changeover Switch: Combination gas/oil units only (MMG#2). Series Features Optional Feature Flame Safeguard UV Scanner Mode of Operation Full Modulation Firing Auto-Manual Firing Rate Control 1 1 1 1 1 1 Cam Trim Ignition Gas/Electric Pilot and Ignition Transformer 2 2 2 2 2 Direct Spark (ML) Oil Components -Way Solenoid Valve 2-Way Solenoid Valve -Way ized POC Valve 2-Way ized POC Valve Atomizing Air Proving Switch Low Oil Pressure Switch Burner Mounted Integral Oil/Air System Gas Components Butterfly Rate Control Valve High & Low Gas Pressure Interlocks Gas Shutoff Cocks (2) ized Valve w/o POC & Solenoid Valve ized Valve w/ POC & Solenoid Valve 1 Standard for full modulation; optional on select parallel positioning systems 2 Standard for MG and MMG#2 burners M-14 to M-22 M-25 M-28 to M-0 M-4 to M-42 M-54 to M-6 M-84 to M-105

Standard Ratings MG - MM#2 - MMG#2: Gas, #2 Oil, Gas/Oil Configuration Gas Input MBH #2 Oil Input GPH BHP @ 80% Eff. Blower HP "S" 1 Blower HP "P" 2 Integral Oil/ Air System HP Phase Standard Gas Train Pipe Size (in.) Min. Gas Press. ("w.c.) Model No. & Frame Size M-14-1 1,400 10.0 1/2 - /4 1 10.9 M-16-1 1,680 12.0 40 1/2 - /4 1 15.7 M-19-1 1,960 14.0 47 1/2 - /4 1 1/2 8.8 M-22-1 2,200 15.7 52 1/2 - /4 1 1/2 10. M-25-2 2,490 18.0 59 2 - /4 1 1/2 10.1 208 / 20 / 460 / M-28-2 2,800 20.0 67 2 - /4 1 1/2 12.0 M-0-2,150 22.5 75 2 - /4 1 1/2 14.9 M-4-,500 25.0 8 2 2 1 1 1/2 19.0 M-42-4,200 0.0 104 2 2 1 2 9.2 20 / 460 / M-54-5,600 40.0 1 2 1 2 16.1 M-6-6,00 45.0 150 2 2 20. M-84-4 8,400 60.0 200 5 7 1/2 2 2 1/2 18.0 460 / M-105-4 10,500 75.0 250 7 1/2 7 1/2 2 16.0 1 Use model "S" up to 0.75" w.c. furnace pressure, consult factory for higher pressures 2 Use model "P" up to 2.0" w.c. furnace pressure, consult facotry for higher pressures Standard gas pressures only, consult factory for lower gas pressures Input is based on fuel BTU content, listed furnace pressure and altitude of 2,000 feet or less. If altitude > 2,000 feet and < 8,000 feet, derate capacity 4% per 1,000 feet over 2,000. Consult factory for higher altitudes. If furnace pressure exceeds listed value, derate capacity 5% for every 0.5" w.c. of pressure in excess of stated. Consult factory if derate exceeds 20%. Gas input is based on natural gas with 1,000 BTU/cu.ft. and 0.60 gravity. For total pressure at manifold, add furnace pressure. Oil input based on 140,000 BTU/gal and the aforementioned conditions. Consult factory for 50 Hz. applications. 4

Standard Dimensions MG - MM#2 - MMG#2: Gas, #2 Oil, Gas/Oil Configuration Burner Frame Size Boiler HP DIM Size 1 Size 2 Size Size 4 Length in inches Overall length E 40 41 /4 44 7/8 54 /4 Width in inches Center line to right side K 14 7/8 1 7/8 14 /8 15 1/8 Center line to left side L 18 19 /4 19 /8 24 Height in inches Center line to top G 9 1/4 10 10 /4 16 1/2 Center line to bottom H 12 /8 15 1/2 19 2 Dry oven dimensions in inches Diameter of dry oven A 12 1 15 7/8 19 Depth of dry oven C 6 6 9 10 Mounting flange dimensions in inches Diameter B 15 16 20 2 Flange to hinge D 2 1/2 25 /8 28 7/8 5 1/8 Bolt hole diameter M 1/2 1/2 15/16 15/16 Bolt circle diameter P 1 /4 14 1/2 18 1/2 21 Hinge swing dimensions in inches Hinge swing radius Q 2 24 25 Center line to outer hinge clearance R 24 1/2 25 /8 26 4 1/8 Gas inlet dimensions in inches Mounting flange to gas inlet F 1 7/8 1 7/8 5/8 /4 Accompanying dimensions, while sufficiently accurate for layout purposes, must be confirmed for construction. 5

Technical Data Uncontrolled Emissions Configuration (MM, MMG) 1.4-10.5 MM BTU/H NG; 9.6-72.4 GPH #2-5 OIL UL listed with choice of NFPA, CSD-1, GAP, and FM for U.S. or Canadian units Standard equipment: 450 RPM motor, panel signal lights (Power On, Main Fuel, Ignition, Flame Failure), dry oven and gasket, combustion air proving switch, high fire air proving switch, 120/1/60 control circuit, burner mounted panel, hinged blast tube with right-hand swing. Gas and gas/oil units only: shipped loose gas train. Combustion Control System options: Parallel Positioning Combustion Control System with O 2 Trim and Variable Frequency Drive (VFD) Fuel options: Main Fuel: #2-5 oil - Air atomized (MM) or Combination natural gas/ #2-5 oil - air atomized (MMG). Igniter Fuel: Natural gas and/or propane. Fuel Changeover Switch: Combination gas/oil units only (MMG). Series Features Optional Feature Flame Safeguard IR Scanner Mode of Operation Full Modulation Firing Auto-Manual Firing Rate Control 1 1 1 1 1 1 Cam Trim Ignition Gas/Electric Pilot and Ignition Transformer 2 2 2 2 2 Direct Spark (MM) Oil Components -Way Solenoid Valve 2-Way Solenoid Valve -Way ized POC Valve 2-Way ized POC Valve Atomizing Air Proving Switch Low Oil Pressure Switch Burner Mounted Integral Oil/Air System Nozzle Line Heater with Cold Oil Lockout Gas Components Butterfly Rate Control Valve High & Low Gas Pressure Interlocks Gas Shutoff Cocks (2) ized Valve w/o POC & Solenoid Valve ized Valve w/ POC & Solenoid Valve 1 Standard for full modulation; optional on select parallel positioning systems 2 Standard for MM and MMG burners Standard for #4-5 oil only M-14 to M-22 M-25 M-28 to M-0 M-4 to M-42 M-54 to M-6 M-84 to M-105 6

Standard Ratings MM - MMG: #2-5 Oil, Gas/Oil Configuration Gas Input MBH #2-5 Oil Input GPH BHP @ 80% Eff. Blower HP "S" 1 Blower HP "P" 2 Integral Oil/ Air System HP Phase Nozzle Line Heater Phase (kw) Standard Gas Train Pipe Size (in.) Min. Gas Press. ("w.c.) Model No. & Frame Size M-14-1 1,400 9.6 1/2 - /4 1 10.9 M-16-1 1,680 11.6 40 1/2 - /4 1 15.7 M-19-1 1,960 1.5 47 1/2 - /4 1 1/2 8.8 M-22-1 2,200 15.2 52 1/2 - /4 1 1/2 10. M-25-2 2,490 17.4 59 2 - /4 1 1/2 10.1 208 / 20 / 460 / M-28-2 2,800 19. 67 2 - /4 1 1/2 12.0 M-0-2,150 21.7 75 2 - /4 1 1/2 14.9 M-4-,500 24.1 8 2 2 1 1 1/2 19.0 M-42-4,200 29.0 104 2 2 1 2 9.2 20 / 460 / M-54-5,600 8.6 1 2 1 2 16.1 M-6-6,00 4.5 150 2 2 20. M-84-4 8,400 58.0 200 5 7 1/2 2 5 2 1/2 18.0 460 / M-105-4 10,500 72.4 250 7 1/2 7 1/2 2 5 16.0 1 Use model "S" up to 0.75" w.c. furnace pressure, consult factory for higher pressures 2 Use model "P" up to 2.0" w.c. furnace pressure, consult facotry for higher pressures Standard gas pressures only, consult factory for lower gas pressures Input is based on fuel BTU content, listed furnace pressure and altitude of 2,000 feet or less. If altitude > 2,000 feet and < 8,000 feet, derate capacity 4% per 1,000 feet over 2,000. Consult factory for higher altitudes. If furnace pressure exceeds listed value, derate capacity 5% for every 0.5" w.c. of pressure in excess of stated. Consult factory if derate exceeds 20%. Gas input is based on natural gas with 1,000 BTU/cu.ft. and 0.60 gravity. For total pressure at manifold, add furnace pressure. Oil input based on 145,000 BTU/gal and the aforementioned conditions. Consult factory for 50 Hz. applications. 7

Standard Dimensions MM - MMG: #2-5 Oil, Gas/Oil Configuration Burner Frame Size Boiler HP DIM Size 1 Size 2 Size Size 4 Length in inches Overall length E 40 41 /4 44 7/8 54 /4 Width in inches Center line to right side K 15 5/8 14 1/2 15 15 /4 Center line to left side L 18 19 /4 19 /8 24 Height in inches Center line to top G 9 1/4 10 10 /4 16 1/2 Center line to bottom H 12 /8 15 1/2 19 2 Dry oven dimensions in inches Diameter of dry oven A 12 1 15 7/8 19 Depth of dry oven C 6 6 9 10 Mounting flange dimensions in inches Diameter B 15 16 20 2 Flange to hinge D 2 1/2 25 /8 28 7/8 5 1/8 Bolt hole diameter M 1/2 1/2 15/16 15/16 Bolt circle diameter P 1 /4 14 1/2 18 1/2 21 Hinge swing dimensions in inches Hinge swing radius Q 2 24 25 Center line to outer hinge clearance R 24 1/2 25 /8 26 4 1/8 Gas inlet dimensions in inches Mounting flange to gas inlet F 1 7/8 1 7/8 5/8 /4 Accompanying dimensions, while sufficiently accurate for layout purposes, must be confirmed for construction. 8

Technical Data Uncontrolled Emissions Configuration (ME, MEG) 1.4-10.5 MM BTU/H NG; 9. - 70 GPH #2-6 OIL UL listed with choice of NFPA, CSD-1, GAP, and FM for U.S. or Canadian units * ME & MEG 14-0 are not UL listed Standard equipment: 450 RPM motor, panel signal lights (Power On, Main Fuel, Ignition, Flame Failure), dry oven and gasket, combustion air proving switch, high fire air proving switch, 120/1/60 control circuit, burner mounted panel, hinged blast tube with right-hand swing. Gas and gas/oil units only: shipped loose gas train. Combustion Control System options: Parallel Positioning Combustion Control System with O 2 Trim and Variable Frequency Drive (VFD) Fuel options: Main Fuel: #6 oil - air atomized (ME) or Combination natural gas/ #6 oil - air atomized (MEG). Igniter Fuel: Natural gas and/or propane. Fuel Changeover Switch: Combination gas/oil units only (MEG). Series Features Optional Feature Flame Safeguard IR Scanner Mode of Operation Full Modulation Firing Auto-Manual Firing Rate Control 1 1 1 1 1 1 Cam Trim Ignition Gas/Electric Pilot and Ignition Transformer 2 2 2 2 2 Oil Components -Way Solenoid Valve 2-Way Solenoid Valve -Way ized POC Valve 2-Way ized POC Valve Atomizing Air Proving Switch Low Oil Pressure Switch Burner Mounted Oil Metering System Separately Mounted Air Compressor Module Nozzle Line Heater with Cold Oil Lockout Gas Components Butterfly Rate Control Valve High & Low Gas Pressure Interlocks Gas Shutoff Cocks (2) ized Valve w/o POC & Solenoid Valve ized Valve w/ POC & Solenoid Valve 1 Standard for full modulation; optional on select parallel positioning systems 2 Standard for ME and MEG burners Standard for #4-5 oil only M-14 to M-22 M-25 M-28 to M-0 M-4 to M-42 M-54 to M-6 M-84 to M-105 9

Standard Ratings ME - MEG: #2-6 Oil, Gas/Oil Configuration Gas Input MBH #2-6 Oil Input GPH BHP @ 80% Eff. Blower HP "S" 1 Blower HP "P" 2 Integral Oil/Air System HP Phase Separate Compressor Module HP Oil Metering System HP Nozzle Line Heater Phase (kw) Standard Gas Train Pipe Size (in.) Min. Gas Press. ("w.c.) Model No. & Frame Size M-14-1 1,400 9. 1/2 - /4 - - 1 10.9 M-16-1 1,680 11.2 40 1/2 - /4 - - 1 15.7 M-19-1 1,960 1.1 47 1/2 - /4 - - 1 1/2 8.8 M-22-1 2,200 14.7 52 1/2 - /4 - - 1 1/2 10. M-25-2 2,490 16.8 59 2 - /4 - - 1 1/2 10.1 208 / 20 / 460 / M-28-2 2,800 18.7 67 2 - /4 - - 1 1/2 12.0 M-0-2,150 21.0 75 2 - /4 - - 1 1/2 14.9 M-4-,500 2. 8 2 2-1/2 1 1/2 19.0 M-42-4,200 28.0 104 2 2-1/2 2 9.2 20 / 460 / M-54-5,600 7. 1 2-1/2 2 16.1 M-6-6,00 42.0 150-1/2 2 20. M-84-4 8,400 56.0 200 5 7 1/2-1/2 5 2 1/2 18.0 460 / M-105-4 10,500 70.0 250 7 1/2 7 1/2-1/2 5 16.0 1 Use model "S" up to 0.75" w.c. furnace pressure, consult factory for higher pressures 2 Use model "P" up to 2.0" w.c. furnace pressure, consult facotry for higher pressures Standard gas pressures only, consult factory for lower gas pressures Input is based on fuel BTU content, listed furnace pressure and altitude of 2,000 feet or less. If altitude > 2,000 feet and < 8,000 feet, derate capacity 4% per 1,000 feet over 2,000. Consult factory for higher altitudes. If furnace pressure exceeds listed value, derate capacity 5% for every 0.5" w.c. of pressure in excess of stated. Consult factory if derate exceeds 20%. Gas input is based on natural gas with 1,000 BTU/cu.ft. and 0.60 gravity. For total pressure at manifold, add furnace pressure. Oil input based on 150,000 BTU/gal and the aforementioned conditions. Consult factory for 50 Hz. applications. 10

Standard Dimensions ME - MEG: #2-6 Oil, Gas/Oil Configuration Burner Frame Size Boiler HP DIM Size 1 Size 2 Size Size 4 Length in inches Overall length E 40 41 /4 44 7/8 54 /4 Width in inches Center line to right side K 15 5/8 14 1/2 15 15 /4 Center line to left side L 18 19 /4 19 /8 24 Height in inches Center line to top G 9 1/4 10 10 /4 16 1/2 Center line to bottom H 12 /8 15 1/2 19 2 Dry oven dimensions in inches Diameter of dry oven A 12 1 15 7/8 19 Depth of dry oven C 6 6 9 10 Mounting flange dimensions in inches Diameter B 15 16 20 2 Flange to hinge D 2 1/2 25 /8 28 7/8 5 1/8 Flange to gas inlet F 1 7/8 1 7/8 5/8 /4 Bolt hole diameter M 1/2 1/2 15/16 15/16 Bolt circle diameter P 1 /4 14 1/2 18 1/2 21 Hinge swing dimensions in inches Hinge swing radius Q 2 24 25 Center line to outer hinge clearance R 24 1/2 25 /8 26 4 1/8 Gas inlet dimensions in inches Mounting flange to gas inlet F 1 7/8 1 7/8 5/8 /4 Accompanying dimensions, while sufficiently accurate for layout purposes, must be confirmed for construction. 11 11

51 21st Street, Monroe, WI 5566 USA 608.25.141 info@ind-comb.com ind-comb.com Printed in the USA 201 Industrial Combustion IC-SA-1614 06/1