TURBOGENERATOR DYNAMIC ANALYSIS TO IDENTIFY CRITICAL SPEED AND VIBRATION SEVERITY

Similar documents
Research on vibration reduction of multiple parallel gear shafts with ISFD

Effects of shaft geometric unconformities on the rotor-dynamic behavior in hard coupled equipment

Balancing with the presence of a rub

719. Diagnostic research of rotor systems with variable inertia moment

Forced vibration frequency response for a permanent magnetic planetary gear

Effect Of Bearing Faults On Dynamic Behavior And Electric Power Consumption Of Pumps

Balancing and over-speed testing of flexible rotors

Vibration studies and on-site balancing of GT-1 assembly

Training Courses Information

Analysis and control of vehicle steering wheel angular vibrations

55. Estimation of engine piston system wear using time-frequency method

Vibration Measurement and Noise Control in Planetary Gear Train

Analysis on natural characteristics of four-stage main transmission system in three-engine helicopter

IDENTIFICATION OF ABNORMAL ROTOR DYNAMIC STIFFNESS USING MEASURED VIBRATION INFORMATION AND ANALYTICAL MODELING

CHAPTER 1. Introduction and Literature Review

THE APPLICATION OF WHOLE ENGINE FINITE ELEMENT MODEL ON CRITICAL SPEED ANALYSIS FOR THE COMMERCIAL AERO-ENGINE ROTOR

CRITICAL SPEED ANALYSIS FOR DUAL ROTOR SYSTEM USING FINITE ELEMENT METHOD

Continuous Journey. Regreasing of Bearings. Risk Calculation Methodology. the magazine for maintenance reliability professionals

Trouble Shooting in Vertical Fire Hydrant Pump by Vibration Analysis - A Case Study

ELECTROMECHANICAL OPTIMIZATION AGAINST TORSIONAL VIBRATIONS IN O&G ELECTRIFIED TRAINS MICHELE GUIDI [GE O&G] ALESSANDRO PESCIONI [GE O&G]

Balancing of aeroderivative turbine

Shimmy Identification Caused by Self-Excitation Components at Vehicle High Speed

Experimental research on dynamic characteristics of gas bearing-rotor with different radial clearances

Vibration Diagnostic Software. Proven Automated Diagnostic Technology for Machinery Condition Assessment

DEVELOPMENT OF VIBRATION CONDITION MONITORING SYSTEM APPLYING OPTICAL SENSORS FOR GENERATOR WINDING INTEGRITY OF POWER UTILITIES

ISCORMA-3, Cleveland, Ohio, September 2005

DEVELOPMENT AND IMPLEMENTATION OF VFD ACTIVE DAMPING TO SMOOTH TORSIONAL VIBRATIONS ON A GEARED TRAIN

VALIDATION OF A HUMAN-AND-HARDWARE-IN-THE- LOOP CONTROL ALGORITHM

XY Measurements for Radial Position and Dynamic Motion in Hydro Turbine Generators

CASE STUDY ON RESOLVING OIL WHIRL ISSUES ON GAS COMPRESSOR

ALERT Analysis Systems

Application of Airborne Electro-Optical Platform with Shock Absorbers. Hui YAN, Dong-sheng YANG, Tao YUAN, Xiang BI, and Hong-yuan JIANG*

Vibration Report. : Greater Noida. Date of Visit : 9 th & 10 th March 2016 OUR CONTACT: REPORT PREPARED BY. Mr. Udit Sharma

DAMAGE IDENTIFICATION AND VIBRATION ANALYSIS TECHNIQUE FOR GEAR BOX

Based on the findings, a preventive maintenance strategy can be prepared for the equipment in order to increase reliability and reduce costs.

ON THE DETERMINATION OF BEARING SUPPORT PEDESTAL STIFFNESS USING SHAKER TESTING

PNEUMATIC HIGH SPEED SPINDLE WITH AIR BEARINGS

Case Study - Fluidic Instability

WHITE PAPER. Detecting Rolling Element Bearing Faults Using the Echo Wireless Vibration Monitoring System

Vibration Fundamentals Training System Hands-On Turnkey System for Teaching Vibration Fundamentals

ROTATING MACHINERY DYNAMICS

Passive Vibration Reduction with Silicone Springs and Dynamic Absorber

TURBOLINK BEARINGS L U I D I L M E A R I N G S. Manufcturing Engineering Consulting Service & Retrofit

A Model of Wind Turbine s Flexibility Shaft

Harmonic Analysis of Reciprocating Compressor Crankcase Assembly

The Study of Effect of Imbalance on Vibration of Rotor Bearing System

STIFFNESS CHARACTERISTICS OF MAIN BEARINGS FOUNDATION OF MARINE ENGINE

Measurement Types in Machinery Monitoring

A STUDY OF THE CENTRIFUGAL COMPRESSOR DISCHARGE PIPELINE CONSTRAINED OSCILLATION. KIRILL SOLODYANKIN*, JIŘÍ BĚHAL ČKD KOMPRESORY, a.s.

1. Introduction

Dynamic Vibration Analysis of Gear Box Casing Using ANSYS Software

A CASE STUDY OF A FLOW-INDUCED TORSIONAL RESONANCE

Throwback Thursday :: Bently Nevada Dual Probe Versus Shaft Rider

Using energy storage for modeling a stand-alone wind turbine system

CONTENTS. 5 BALANCING OF MACHINERY Scope Introduction Balancing Machines Balancing Procedures

Theoretical and Experimental Investigation of Compression Loads in Twin Screw Compressor

XXIII Konferencja Naukowa POJAZDY SZYNOWE 2018

RELIABILITY IMPROVEMENT OF ACCESSORY GEARBOX BEVEL DRIVES Kozharinov Egor* *CIAM

Design and Test of Transonic Compressor Rotor with Tandem Cascade

Composite Long Shaft Coupling Design for Cooling Towers

Expand your vibration program to new heights.

HELICOPTER TAIL ROTOR ANALYSIS: EXPERIENCE IN AGUSTA WITH ADAMS

laser shaft alignment

Subsynchronous Shaft Vibration in an Integrally Geared Expander-Compressor due to Vortex Flow in an Expander

Analysis on fatigue life of a certain gear transmission system

Experimental Analyses of Vibration and Noise of Faulted Planetary Gearbox

DESIGN OPTIMIZATION FOR VIBRATION LEVEL OF ROOT BLOWER WITH LOAD CONDITION

Dynamic Responses of Rotor Drops onto Auxiliary Bearing with the Support of Metal Rubber Ring

11 Problems 11 Solutions Case Histories of 11 Machinery Vibration Problems Part 2

Pump Coupling & Motor bearing damage detection using Condition Monitoring at DTPS

Gearbox Misalignment on Combustion Gas Turbine Generator

Tooth Shape Optimization of the NGW31 Planetary Gear Based on Romax Designer

Is Low Friction Efficient?

Advanced Rotordynamic Bearing Technology And Case Histories in the Rotating Machinery Industry

Thermomechanical Analysis of the Turbo-Compressor Sliding Bearing Mount Units

COMPANDER VIBRATION TROUBLESHOOTING. Sébastien Jaouen, Cryostar Cliff Bauer, MOL Stéphane Berger, Flender Alain Guéraud, Cryostar

Detection of Fault in Gear Box System using Vibration Analysis Method

Effect Of Main Steam Temperature At Inlet On Turbine Shaft Vibration

AERO AERODERIVATIVE AND INDUSTRIAL GAS TURBINES NON INTRUSIVE SENSOR SYSTEM

Improving predictive maintenance with oil condition monitoring.

INVESTIGATION OF HIGH VIBRATION ON LOW PRESSURE STEAM TURBINES

Rotor bearing system FEA analysis for misalignment Sachin D.Dere 1, Laxmikant Dhamande 2

TWO PLANE BALANCING OF A CONICAL ROTOR DRIVEN BY VERTICAL BELT SYSTEM DESIGNED TO REDUCE GYRO EFFECT

DEVELOPMENT OF A DRIVING CYCLE FOR BRASOV CITY

Design and Development of Test Setup to Study the Basic Procedure of Vibration analysis

AXLE HOUSING AND UNITIZE BEARING PACK SET MODAL CHARACTERISATION

11 Problems 11 Solutions Case Histories of 11 Machinery Vibration Problems Part 1

Experimental Study on Torsional Vibration of Transmission System Under Engine Excitation Xin YANG*, Tie-shan ZHANG and Nan-lin LEI

Design and Stress Analysis of Crankshaft for Single Cylinder 4-Stroke Diesel Engine

Noise Reduction of Accumulators for R410A Rotary Compressors

Investigations of Oil Free Support Systems to Improve the Reliability of ORC Hermetic High Speed Turbomachinery

APPLICATION OF A NEW TYPE OF AERODYNAMIC TILTING PAD JOURNAL BEARING IN POWER GYROSCOPE

Case History: Field Balancing of a Bowed Steam Turbine Rotor. My Background

Structural Analysis of Pick-Up Truck Chassis using Fem

Transient Speed Vibration Analysis Insights into Machinery Behavior

Condition Monitoring of Electrical Machines ABB MACHsense Solution

ROTOR DYNAMICS ANALYSIS AND VIBRATION MEAS- UREMENT OF THE COMPOSITE FLYWHEEL BEARING SYSTEM FOR ENERGY STORAGE

INTERCONNECTION POSSIBILITIES FOR THE WORKING VOLUMES OF THE ALTERNATING HYDRAULIC MOTORS

A STUDY ON JACK-UP GEARBOX DESIGN FOR DRILLSHIPS

Evaluating and Correcting Subsynchronous Vibration in Vertical Pumps

Transcription:

U.P.B. Sci. Bull., Series D, Vol. 77, Iss. 3, 2015 ISSN 1454-2358 TURBOGENERATOR DYNAMIC ANALYSIS TO IDENTIFY CRITICAL SPEED AND VIBRATION SEVERITY Claudiu BISU 1, Florian ISTRATE 2, Marin ANICA 3 Vibration analysis is the main technique in diagnosing dynamic behavior of industrial machinery and equipment. This technique is applied for the vibration diagnosis 40MW turbo generator which is driven by a gas turbine. Due to high vibration amplitudes of bearings a numerical analysis of the generator rotor is used to highlight the dynamic phenomena and determination of critical speeds. So to validate the numerical model and identify critical speed a complex experimental protocol was conducted to measure both the coupling vibration monitoring system in real time and local measurement by fixing the sensor on the bearing housing. The use of advanced digital signal processing led to highlighting the main faults and obtains the final solution to reduce the amplitude of vibration. Keywords: vibration, critical speed, generator, mechanical looseness 1. Introduction Power plants using gas turbines are one of the most effective solutions for producing electricity. Study of dynamic and thermal phenomena represented and represents topical energy industry around the globe. The importance of these machines required the development of new systems and techniques for monitoring the dynamic behavior of the entire chain of rotor bearings. These solutions are absolutely necessary in operating conditions from becoming more severe. In reality, however, no rotor operation is vibration-free due to various excitations and so attempts of researchers are aimed at minimizing the vibration level [1]. The operating conditions of steam turbine rotor are severe, which include high temperature, high pressure [2] and also high vibration. Turbo-generator rotor shaft may vibrations due to variable stiffness of bearings, a random exciting torque, the rotors misalignment, the whirling shaft, the disturbance of electricity, etc. In the resonance condition the vibration amplitudes may reach very quickly high unacceptable values [1]. Long term operation under such conditions may induce low cycle fatigue in rotor s material [2] and also in other turbine components. Because of the importance of the rotors 1 Associate professor, Dept.of Machines and Production Systems, University POLITEHNICA of Bucharest, Romania, e-mail: claudiu.bisu@upb.ro 2 Eng. Dipl., Istrate Energietechnik, Swiss e-mail: florian.i@istratech.com 3 Eng. Dipl., Digitline Automatizari, Romania, e-mail: office@digitline.ro

224 Claudiu Bisu, Florian Istrate, Marin Anica in the power plant, the dynamic analysis and diagnosis attracts many researchers [3, 4]. Vibration diagnostics allow highlighting the various phenomena which occur during turbine operation. The experimental tests were performed on a 40MW gas turbo-generator. The gas turbo-generator is composed of a compressor, rotor turbine a gear box and the generator with the excitation side. This paper considers the determination of critical speed on the generator and also analyzes vibration severity level. 2. Research context In this paper the main focus is the determination of critical speed of generator rotor shaft and the analysis of the vibrations severity to highlight the most important effect of vibration and to identify the vibration cause. Gas turbine and generator vibrations have been recorded, with the main target to analyze and diagnose the vibration behavior and define the next maintenance activities. The main reason of the measurements was an observation from the control room operation personnel that it is a vibration variation with the reactive power at the generator bearing, load gear. The gas turbo-generator configuration and description of the components elements is show in the figure 1. Fig.1. The configuration of the gas turbo-generator 3. Experimental setup The vibration analysis was performed in two different ways, absolute vibration using the original speed sensors of the turbo-generator in control room and absolute vibration on the bearing housings of the gear-box and generator in local measurement. In order to analyze the vibration signature of the gear-box, accelerometers have been installed and vibration recorded continuously up to a frequency of 10 khz.

Turbogenerator dynamic analysis to identify critical speed and vibration severity 225 The measurements have been performed during the start-up and loading process, to evaluate the critical speeds locations and magnitude, to identify possible changes with load variations. In order to evaluate the vibration amplitude sensitivity with MVAR variation, the unit was loaded gradually at zero MVAR up to a full load of 41 MW and at this active power the reactive was changed. The experimental equipment used for measurement is divided in two groups: control room measurement and local measurement. For the control room monitoring system the equipment consist of a CRIO 9014 National Instrument and Fastview Digitline software, figure 2. The condition monitoring system using in control room is a Mark V cubical and the permanent vibration transmitters provide the signals from vertical direction of the existent bearing sensors with 150mV/IPS sensitivity. The vibrations are measured first as vibration velocity; peak values pk and r.m.s. values. Speed sensors, installed temporary on site, on Turbine side on the extension shaft to high speed gear and on generator side at the exciter side (two laser sensors). The control room acquisition signal settings are performed with 5000 S/s/ch with 24 bits resolution. Fig.2. The experimental setup for control room measurement data On the local measurement the local signal source derived from temporary sensors, accelerometers with 100 mv/g sensitivity which have been installed on vertical, horizontal and axial direction on gearbox housing at high speed gear, load gear and exciter side of generator. The speed reference is the speed laser sensor installed on exciter side of generator. For acquisition and signal processing in local measurement configuration was used two modules National Instruments USB 4432 with a speed of 25kS/s with 24 bits resolution, figure 3.

226 Claudiu Bisu, Florian Istrate, Marin Anica Fig.3. The experimental setup for control room measurement data The exact position of the sensors and measurement protocol in local measurement configuration is shown in Figure 4. Fig.4. Sensor position on the bearing: horizontal (H), vertical (V) and axial direction (A) 5. Vibration issue Vibration measurement is made in terms of gas turbo-generator startup and according with certain operating conditions. The first action of diagnosis is to evaluate the vibration effect and to identify the cause o vibration, the main

Turbogenerator dynamic analysis to identify critical speed and vibration severity 227 purpose of the maintenance report for overhaul. During the start-up the bode diagram highlights a resonance of generator on gearbox bearing side at 1587 RPM and the second one at 2795 RPM which is not a resonance corresponding to the excitation bearing, figure 5. Fig.5. Bode diagram for generator bearing on gear-box side The axial vibration of the gear-box housing is large amplitude and has a resonance at the same speed, figure 6. Local resonance is suspected on the gearbox casing due to the mechanical looseness of the foundation. Fig.6. Bode diagram for gear-box bearing on turbine side The vibration amplitude for generator bearing on excitation side is presented in table 1.

228 Claudiu Bisu, Florian Istrate, Marin Anica Generator Horizontal Vertical Axial mm/s rms Excitation bearing 2.5 4.5 1.2 Gear-box bearing 2.4 5.5 4.8 Table 1 According with the ISO standard 10816 and gas turbo-generator specific data the vibration levels exceed limits. In this case the dynamic rotor theory is used to calculate the critical behavior and to identify critical speed. 6. Theoretical model of generator rotor To characterize the dynamics of generator rotor was made a numerical model to emphasize the critical speed. A typical dynamic behavior in rotating machinery is the critical frequencies where in most cases the flexible rotors are two critical speeds, figure 7 [3, 4, 5]. Fig.7. Theoretical meshing of the generator rotor For critical speed determination for the numerical model require the radial stiffness for the bearings. The stiffness bearings are provided by the manufacturer of the rotor generator, figure 8.

Turbogenerator dynamic analysis to identify critical speed and vibration severity 229 Fig.8. Bearings stiffness on horizontal and vertical direction The model results are shows in figure 9 and 10 for the rotor bearings: excitation side (drive-end DE) and for gearbox side (non drive-end NDE). Fig.9. Critical speed for excitation bearing side (drive-end DE) Fig.10. Critical speed for gearbox bearing side (non drive-end NDE)

230 Claudiu Bisu, Florian Istrate, Marin Anica The first critical speed calculate is around 1700 RPM and the second one is 3200 RPM. The two critical speeds are the result of dynamic rotor model and are also the two critical areas called static and dynamic respectively [5]. The two modes of vibration are confirmed by measurements but do not highlight any critical speed around 2800 RPM which means that this is a local resonance reducer caused by mechanical looseness of the foundation. 6. Vibration analysis and results The proposal repair after vibration diagnosis report consists in: inspection and gear repair; inspection and repair of gearbox anchor foundation system; alignment of the generator and balancing. The vibration trend during the gas turbo-generator after de overhaul is show in the figure 11, 12 and 13. Fig.11. Vibration trend after overhaul horizontal direction The vibration analysis before the outage was indicating a resonance peak on generator bearing gearbox side, on vertical and axial direction at around 2800 rpm. This resonance was a result of the improper loading of the frame and now it is not present (was shifted over 3000 rpm). After the overhaul is observed vibrations shows a much lower level than before repair. The evolution of vibration parameters presents constant amplitude on the synchronization state. These results show that the foundation problems in terms of anchoring can lead to severe dynamic effects. In this configuration, the gas turbo-generator dynamic stability can be strongly influenced by the lack of structural rigidity.

Turbogenerator dynamic analysis to identify critical speed and vibration severity 231 Fig.12. Vibration trend after overhaul - vertical direction Fig.13. Vibration trend after overhaul - axial direction The vibration level after repair status is presented in the table 1. The vibration amplitude on the excitation bearing of the generator is lower than before repair and the same evolution we have for gear-box bearing were on vertical direction the vibration level is quite low. Generator Horizontal Vertical Axial mm/s rms Excitation bearing 1.8 1.9 1.2 Gear-box bearing 2.9 3.2 4.7 Table 2

232 Claudiu Bisu, Florian Istrate, Marin Anica 6. Conclusions Vibration diagnostics allow highlighting the various dynamic phenomena which occur during gas turbo-generator operation. A vibration issue has been detected and it required a complex dynamic analysis. The vibration analysis was performed in two different ways, absolute vibration using the original speed sensors of the turbo-generator in control room and absolute vibration on the bearing housings of the gear-box and generator in local measurement. All tests are performed on three-dimensional configuration. The first action of diagnosis is to evaluate the vibration effect and to identify the cause o vibration. During the start-up the vibration analysis highlights a resonance of generator on gearbox bearing side at 1587 RPM and the second one at 2795 RPM which is not a resonance corresponding to the excitation bearing. For this reason a numerical analysis of the rotor dynamic was achieved by developing a theoretical model that allowed the determination of critical speeds. The vibration analysis show a local resonance reducer caused by mechanical looseness of the foundation. This prediction was confirmed after the repair and reinforcement of the frame structure. The model validation and prediction confirmation was done by testing the gas turbo-generator after repair when the vibration level decreases and the critical speed of 2800 RPM does not exist. A complete analysis is proposed in the future to consider the entire diagnosis such as acceleration, angular position of vibrations vector, unbalance, misalignment, bending shaft, electric parameters etc.. R E F E R E N C E S [1]. Gao Wenzhi, Hao Zhiyong, Active control and simulation test study on torsional vibration of large turbo-generator rotor shaft, Mechanism and Machine Theory 45 (2010) 1326 1336, 2010. [2]. Yong-Jian Sun, Xiao-Qiang Liu, Li-Sheng Hu, Xue-Yan Tang, Online life estimation for steam turbine rotor, Journal of Loss Prevention in the Process Industries 26 (2013). [3]. S.E. Moussavi Torshizi, S.M. Yadavar Nikravesh, A. Jahangiri, Failure analysis of gas turbine generator cooling fan blades, Engineering Failure Analysis 16 (2009) 1686 1695, 2009. [4]. Mel Maalouf, Gas Turbine Vibration Monitoring An Overview, Bently Nevada, Products, GE Energy, Vol.25 No.1 2005. [5]. E.J. Gunter, Field balancing 70MW gas turbine-generators, International Conference on Rotordynamics, 14-17 September, 1986.