SECTION ROLLER WINDOW SHADES

Similar documents
D. Operation and Maintenance Data. In addition to items specified in Division 1 Section "Operation and Maintenance Data," include the following:

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

ROLLER SHADE SPECIFICATIONS

Multi-Institutional Academic Health Science & Research Center Evansville, IN

SOMFY SYSTEMS, INC. MASTER SPECIFICATION Rev 06/2013

University of Houston Master Construction Specifications Insert Project Name

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

SECTION VARIABLE FREQUENCY DRIVE UNITS

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

University of Delaware

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

Special Specification 6058 Battery Back-Up System for Signal Cabinets

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

PDI PowerWave 2 Bus System

TECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III

SECTION ENCLOSED CONTROLLERS

SECTION LIFT ARM PARKING GATES

Model LA 4400 Time Delay OFF Controller

IN2 Enclosed Switches and Circuit Breakers

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

Quik-Spec Coordination Panelboard Specifications

SECTION MOTORS AND CONTROLS FOR WINDOW COVERINGS. Logo Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

1250W 12VDC PowerVerter Ambulance/EMS Inverter/Charger with 2 Hospital Grade Outlets

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Patient Care Facility

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

750W PowerVerter RV Inverter/Charger with Hardwire Input/Output

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

Model LA 4100 Time Delay OFF Controller

Industry Compliance The cabinet and modules are Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc.

Paralleling Equipment

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

3000W PowerVerter RV Inverter/Charger with Hardwire Input/Output

Model LA 4300 Time Delay OFF Controller

This Manu-Spec specifies automatic swinging gate operators and accessories for residential, commercial, and industrial use GATE OPERATORS

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

ROLLER SHADE SPECIFICATIONS

Illuminator Series CR NEMA 3R

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Patient Care Facility Multiple Room Configuration Style 3 W/ Ver 4.41 pcb & Pulse Relay pcb(s)

SECTION VistaGard ROLLING GRILLES CLEAR PANEL DESIGN

WARREN COUNTY, N.Y. M/E REFERENCE

BUSWAY Low Voltage (Pow-R-Flex)

Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

Specification Guide. for RMAX. Direct Replacement. AC Low Voltage. Power Circuit Breakers

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

MODEL NUMBER: APS2448UL

Sola 3000 Guide Specifications

3000W PowerVerter RV Inverter/Charger with Hardwire Input/Output

OTEC Transfer switch open transition

Uninterruptible Power Supplies

ElectroShade Motorized Shade System Table of Contents

Smart Room Control Solution & Programmable Controllers Now Enabling DALI Lighting Control

EXTRUDED ALUMINUM TEMPERED GLASS BALANCED DOORS AND ENTRANCES

Patient Care Facility

Installation Instructions Central Battery Units

SECTION WIRING DEVICES

PROJ. NO SECTION HYDRONIC PUMPS

PNEUMATIC CONTROL SYSTEMS DESIGN AND CONSTRUCTION STANDARD PART 1 - GENERAL. A. Codes and Standards that are Standard at the University:

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

Model #: RV1012ULHW. 12V DC or 120V AC input; 120V AC output (hardwired)

A.C.E.S. Series ACES 3 & 6 MODULE PANELS. System Manual. Touch-Plate Lighting Controls. ACES 3 & 6 Module System Manual

Wilo Stratos Z Variable Speed, Wet Rotor Inline Pumps. Engineering Specification

SECTION MOTOR CONTROL

SECTION DC POWER SUPPLY/BATTERY CHARGER

SECTION RAPIDVIEW MODEL 999. Copyright ARCAT, Inc. All rights reserved

SECTION CENTRIFUGAL HVAC FANS

ElectroShade Motorized Shade System Table of Contents

MECHANICAL AND ELECTRICAL COORDINATION SECTION MECHANICAL AND ELECTRICAL COORDINATION PART 1 - GENERAL

Model #: APS3636VR. 36V DC or 120V AC input; 120V AC output (hardwired)

Transfer switch OTEC and OTECSE open transition

DORMA Automatics, Inc. 924 Sherwood Drive Lake Bluff, Illinois U.S.A. Toll Free: Fax:

Sola/Hevi-Duty S3K Series Mini-Tower UPS

Quick Start Guide TS 910 & TS 920

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

SECTION AXIAL HVAC FANS

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

SECTION [ ] HIGH PERFORMANCE OVERHEAD HIGH SPEED DOORS. Display hidden notes to specifier. (Don't know how?

SECTION HYDRAULIC FOUR FOLD DOORS MODEL 48 LOUVERS

din rail mounted active tracking filters with surge protection Product Guide DIN RAIL MOUNTED INDUSTRIAL DC UPS Product Guide

DER Commissioning Guidelines Community Scale PV Generation Interconnected Using Xcel Energy s Minnesota Section 10 Tariff Version 1.

DIVISION 16 - ELECTRICAL SECTION 16xx0 MANUFACTURED WIRING SYSTEM ACCESS FLOOR

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

VERTICAL LIFT FIRE/BLAST DOORS

INSTRUCTION BOOK FOR. Cosmopolitan Electrol For Sizes Up To 9' x 12'

PowerVerter 750W RV Inverter/Charger with Hardwire Input/Output

Rotary Disconnect Switches, Bulletin 194R

Transcription:

SECTION ROLLER WINDOW SHADES Specifier: The Specifier/Design Professional is responsible for the accuracy of all project specifications, including system application and coordination with related sections. This guide specification is provided as a convenience and requires editing to match actual project requirements. CRESTRON ELECTRONICS, INC. SHALL NOT BE LIABLE FOR ANY DAMAGES ARISING OUT OF THE USE OF ANY OF ITS GUIDE SPECIFICATIONS. For Crestron design assistance and design review please contact Sales Support Services Department at 800.237.2041 or techsales@crestron.com. PART 1 GENERAL 1.1 SUMMARY A. Section includes: 1. Controlled motorized roller shade system for interior installation. B. Related Requirements: 1.2 REFERENCES 1. Section 06 10 00 - Rough Carpentry 2. Section 07 90 00 - Joint Protection 3. Section 09 20 00 - Plaster and Gypsum Board 4. Section 09 51 23 - Acoustical Tile Ceilings 5. Section 25 13 16 - Integrated Automation Control and Monitoring Network Integration Panels 6. Section 25 14 00 - Integrated Automation Local Control Units 7. Section 25 14 16 - Integrated Automation Application-Specific Control Panels 8. Section 25 15 16 - Integrated Automation Software for Control and Monitoring Networks 9. Section 25 30 00 - Integrated Automation Instrumentation and Terminal Devices 10. Section 25 50 00 - Integrated Automation Facility Controls 11. Section 26 05 00 - Common Work Results for Electrical 12. Section 26 09 23 - Lighting Control Devices 13. Section 26 09 36 - Modular Dimming Controls 14. Section 26 09 43 - Network Lighting Controls 15. Section 27 15 00 - Communications Horizontal Cabling 16. Section 27 41 16 - Integrated Audio-Video Systems and Equipment A. Abbreviations and Acronyms: 1. Nm: newton-meter, unit of torque. CRESTRON: ROLLER WINDOW SHADES 1

2. VAC: alternating current voltage. 3. VDC: direct current voltage. 4. AV: audio-visual. 5. RF: radio frequency. 6. TCP/IP: transmission control protocol/internet protocol. B. Definitions 1. Control: Effecting a change in state by one PC program onto a microprocessor or device. 2. Daylight Harvesting: The dimming of electric lighting sources when natural daylight is available. 3. Load Shedding: Intentional reduction of power consumption to avoid total power disruption due to overloading the circuits or reduction of power consumption to avoid crossing an agreed on threshold of power usage. Load shedding lighting ballasts reduce the light level in response to a signal on the power line. 4. Monitor: Acquisition and presentation of status or operating condition of microprocessors or electrical devices in the network of the monitoring device or program. 5. Scene: Predetermined position of shades and light levels. 6. Scene Selection: Grouping of lighting and window shade controls into groups that will respond to a single scene command. 7. Shading Groups: Grouping rooms for common control of window shades. 8. Transmission Control Protocol/Internet Protocol (TCP/IP): Networking protocols for exchanging data over the World Wide Web and Local Area Networks. 1.3 ACTION SUBMITTALS A. Shop Drawings - Indicate the following: 1. Schematic diagram showing complete motorized shade system and integrated control equipment and accessories. B. Window Treatment Schedule: 1. List each roller shade, location, options, size and special requirements. 1.4 QUALITY ASSURANCE A. Source Requirements: Provide motorized roller shade system, [lighting control system, and AV system] with integrated control, automation and monitoring capability from single manufacturer. 1.5 DELIVERY, STORAGE, AND HANDLING A. Deliver product in unopened factory packaging to predetermined location. B. Store products in unopened factory packaging in a controlled environment: 1. Ambient Temperature: 32 to 104 degrees Fahrenheit. CRESTRON: ROLLER WINDOW SHADES 2

1.6 SITE CONDITIONS 2. Humidity: 0 to 85 percent. A. Environmental Conditions Range: 1.7 WARRANTY 1. Temperature: 32 104 degrees F (0-40 degrees C). 2. Relative Humidity: 10 90 percent, noncondensing. A. Special Warranty: Manufacturer's standard form in which manufacturer agrees to repair or replace components of motorized roller shades and control system that fail in materials or workmanship within the specified warranty period following substantial completion. PART 2 PRODUCTS 2.1 ROLLER WINDOW SHADE SYSTEM A. Basis-of-Design Manufacturer: Subject to compliance with requirements, provide products of Crestron Electronics, Inc., Rockleigh, NJ 07647, Phone (800)237-2041, Fax: (201)767-1903, www.crestron.com B. Description: Motorized roller window shade system shall be composed of the following integrated components: 1. Motorized Roller Shades: a. Internal 24 VDC shade motor. b. Mounting brackets. c. Shade Fabric. 2. Shade Motor Power Supplies. 3. Control Processors. 4. Automation Control Sequences. 5. Control User Interfaces. C. Method of Control Communication: 1. Wired Control. 2. Wireless RF Control. 2.2 MOTORIZED ROLLER SHADES TYPE 1 A. Basis of Design Product: Crestron custom motorized roller shades. B. Roller Shade shall be available in the following mounting types: 1. Inside mount. 2. Outside mount. 3. Coupled mount. CRESTRON: ROLLER WINDOW SHADES 3

4. Pocket mount. 5. Dual mount. C. Motorized Roller Shade Motors: Motorized Roller Shade units shall be equipped with roller drive motors based on shade fabric weight and size and control and power requirements. D. Shade Motor Type 1 1. Basis of Design Product: Crestron, QMT50 DC motor. 2. Tubular, 24 VDC motor. 3. Shade width support: 37 5/8 inch 15 feet. 4. Maximum current draw: 50 Watts. 5. Concealed within shade motor tube. 6. Torque: 6 Nm. 7. Provide wired real-time activity and status feedback to processor. 8. Connections: a. Wired Control: SPECIFIER: The QMT50 connects via Cresnet and ships with cable mounted Cresnet connector and mating Cresnet connector to be connected to installed Cresnet cable. E. Shade Motor Type 2: 1) System connection: Provide power and control via multi-conductor Class 2 cable connected directly to power panel motor terminal. 1. Basis of Design Product: Crestron, QMT30 DC motor. 2. Tubular, 24 VDC motor. 3. Minimum shade width: 18 1/2 inch. 4. Concealed within shade motor tube. 5. Torque: 2 Nm. 6. Provide wireless real-time activity and status feedback to processor. 7. Connections Shade motor shall be available with the following control options: SPECIFIER: The QMT30 will ship with one of two interfaces. Wired control utilizes the CSC-DCCN motor interface (Cresnet cable required for control and 24 VDC power). Wireless control utilizes the CSC-DCEX motor interface (Class 2 cable required for 24 VDC power). 2.3 SHADE FABRIC a. Wired Control: Provide power and communication via multi-conductor Class 2 cable connected from motor interface to power panel motor terminal. b. Wireless Control: Provide power via Class 2 cable connected from motor interface to power panel motor terminal or plug-in transformer. A. Roller shades shall be available with the following fabric options: CRESTRON: ROLLER WINDOW SHADES 4

B. Openness factor: 1. Translucent. 2. Blackout. 3. Transparent 1 percent. 4. Transparent 3 percent. 5. Transparent 5 percent. 6. Transparent 7 percent. 7. Transparent 10 percent. 8. Transparent 17 percent. C. Fabric design: 1. Roller Shade fabric shall be available in multiple design types. D. Fabric color: 1. Roller Shade fabric shall be available in multiple color groups: a. Black. b. Black blends. c. Dark tone. d. Mid tone. e. Neutral. f. White. 2.4 SHADE MOTOR POWER SUPPLIES A. Power Supply Type 1 1. Basis of Design Product: Crestron, CSA-PWS225 panel mounted roller shade power supply and communication hub. 2. Power supply rating and compliance: a. UL Listed. b. FCC Part 15 Class B Digital Device. 3. Motor connection port: a. Three power segments, each segment includes two motors connections. b. Power Segment: 1) Each power segment shall supports two 24 VDC motors. 2) Motors segment power: 75 W Continuous; 100 W Peak. 3) Over current protection: self-resetting thermal fuse. 4) Short circuit protection: replaceable 4A fuse. 4. Communication connection port: a. Two data ports provide connectivity to control network. CRESTRON: ROLLER WINDOW SHADES 5

5. Operation and status Indicator LEDs: a. Main Power. c. Data activity and short circuit. B. Power Supply Type 2 1. Basis of Design Product: Crestron, CSA-PWS450 panel mounted roller shade power supply and communication hub. 2. Power supply rating and compliance: a. UL Listed. b. FCC Part 15 Class B Digital Device 3. Motor connection port: a. Six power segments, each segment includes two motors connections. b. Power Segment. 1) Each power segment shall supports two 24 VDC motors. 2) Motors segment power: 75 W Continuous; 100 W Peak. 3) Over current protection: self-resetting thermal fuse. 4) Short circuit protection: replaceable 4A fuse. 4. Communication connection port: a. Two data ports provide connectivity to control network. 5. Operation and status Indicator LEDs: a. Main Power. c. Data activity and short circuit. C. Power Supply Type 3 1. Basis of Design Product: Crestron, CSA-PWS40 single motor roller shade power supply. 2. Power supply rating and compliance: a. UL Listed. b. FCC Part 15 Class B Digital Device. 3. Motor interface connection: a. 24 VDC flying leads. 1) Support for one 24 VDC motor. 2) Power: 40 W. 3) Over current protection: internal self-resetting thermal fuse. CRESTRON: ROLLER WINDOW SHADES 6

D. Power Supply Type 4 1. Basis of Design Product: Crestron, CSA-PWS300-CAEN integrated enclosure and power. 2. Power supply rating and compliance: a. UL Listed. b. FCC Part 15 Class B Digital Device. 3. Power and Motor interface connection: a. Power supply: 1) Support for up to eight 24 VDC motors. 2) Power: 300 Watts. 3) Short circuit protection: replaceable 4A fuse. b. Power Segment 1) Each power segment shall supports one 24 VDC motor. 2) Motor segment power: 75 W Continuous; 100 W maximum. 3) Over current protection: electronic circuit breaker. 4. Communication connection port: a. One data port provides connectivity to control network. 5. Power indicator LEDs: a. Main power. 6. Overload indicator LEDs: a. Main Power. 7. Data network activity LED. a. Main network. 8. Integrated steal enclosure: a. Surface or flush mount. b. UL and C-UL listed. E. Power Supply Type 5 1. Basis of Design Product: Crestron, CSA-PWS600-CAEN integrated enclosure and power. 2. Power supply rating and compliance: a. UL Listed. b. FCC Part 15 Class B Digital Device. 3. Power and Motor interface connection: a. Power supply: CRESTRON: ROLLER WINDOW SHADES 7

1) Support for up to sixteen 24 VDC motors. 2) Power: two 300 W units. 3) Short circuit protection: replaceable 4A fuse per unit. b. Power Segment: 1) Each power segment shall supports one 24 VDC motor. 2) Motor segment power: 75 W Continuous; 100 W maximum. 3) Over current protection: electronic circuit breaker. 4. Communication connection port: a. One data port provides connectivity to control network. 5. Power indicator LEDs: a. Main power. 6. Overload indicator LEDs: a. Main Power. 7. Data network activity LED. a. Main network. 8. Integrated steal enclosure: 2.5 CONTROL PROCESSORS a. Surface or flush mount. b. UL and C-UL listed. A. As specified in Section 25 50 00. 2.6 AUTOMATION CONTROL SEQUENCES A. Motorized Roller Shade System capabilities: 1. Individual shade control. 2. Grouped shade control. 3. Unlimited grouping capability. 4. Control of individual shade motor or shade group shall not be limited by shade location, shade type, or location of power supply or control unit. 5. Grouping of shade motors shall not be limited by shade location, shade type, or location of power supply or control unit. 6. Actions for individual shades and shade groups: a. Automatically aligned preset stop positions at any user-defined shade height level, measured in percentage of total opening height. b. Automatic, all shades open and all shades closed presets. CRESTRON: ROLLER WINDOW SHADES 8

c. Raise and lower to any position within total range of shade movement. 7. Automated Control: a. All control capabilities shall be accessible by automated event actions. 8. Automated Event Actions: a. System shall dynamically execute any controlled shade action, group of actions, or sequence of actions initiated by events composed of fulfilled conditions and criteria. 9. Automation Event Criteria: a. System states. 2.7 SYSTEM INTEGRATION b. Time-clock register. c. Scheduled occurrences. d. Dynamic conditions. e. Pre-programmed composite of criteria. A. Shade system processor shall support native control network protocol of lighting control system, and AV control system. B. The following integrated systems shall allow unlimited access of sensor data between control processors and systems interfaces. 1. Lighting systems. 2. BMS systems. 3. AV systems. 4. HVAC systems. C. All integrated systems shall communicate via a single unified control protocol. 1. The single control communication protocol shall be the protocol native to user interfaces and control processors. 2. Unified control protocol adaptors and interfaces for the following systems shall be acceptable upon approval by A/E: a. BMS b. HVAC 2.8 CONTROL USER INTERFACES A. As specified in Division 25. PART 3 EXECUTION CRESTRON: ROLLER WINDOW SHADES 9

3.1 EXAMINATION A. Prior to installation, examine work area to verify measurements, and that commencing installation complies with manufacturer's requirements. 3.2 INSTALLATION A. Comply with requirements of Section 12 05 00 - Common Work Results for Furnishings. B. Do not install roller shade or control devices until space is enclosed, HVAC systems are running, and overhead and wet work in roller shade work space are complete. C. Install roller shades, power supplies and control devices in accordance with manufacturer's instructions. D. Install user interfaces in accordance with manufacturer's instructions. E. Grounding: Provide electrical grounding in accordance with NFPA 70. F. Perform setup for each roller shade component. 3.3 PREINSTALLATION MEETING A. Installer of roller shade system to coordinate a meeting of the mechanical and electrical engineer, mechanical and electrical contractor, lighting, and HVAC equipment manufacturers. Include any designers and contractors for any other direct digital control system designed to interact with product of this Section. 1. Discuss interoperability of integrated systems and overall integrated system management and control. 3.4 OPERATING SOFTWARE INSTALLATION A. Install and program software in accordance with this Section to meet the Owner's requirements. Provide current system control and user interface programs and backup copies for the Owner's use. 3.5 SYSTEM STARTUP A. Provide system startup and adjustment to occupied conditions in accordance with manufacturer's recommendations. 3.6 ADJUSTING A. Within 2 months of the date of Substantial Completion provide onsite service to adjust the system to account for actual occupied conditions. 3.7 DEMONSTRATION A. Schedule roller shade system demonstration with Owner to allow verification that shade system controls function as required. B. Instruct owner's staff to adjust, operate and maintain roller shade system. CRESTRON: ROLLER WINDOW SHADES 10

3.8 FIELD QUALITY CONTROL A. Manufacturer's Field Services: Qualified manufacturer's field representative to perform on-site system inspection, startup, and owner demonstration and training. 1. Participation in Pre-installation Conference and pre-wire inspection. 2. Installation inspection. 3. Owner programming conference. 4. Installation of system software and system startup. 5. Owner demonstration and training. 3.9 CLOSEOUT ACTIVITIES A. Demonstration: Schedule roller shade system demonstration with Owner to allow verification that shade system controls function as required. B. Instruct owner's staff to adjust, operate and maintain roller shade system. C. Furnish set of approved submittals and record drawings of actual installation for Owner's personnel in attendance at training session. END OF SECTION CRESTRON: ROLLER WINDOW SHADES 11