DSE201 Compact design with enhanced protection

Similar documents
DS201 - DS202C New residual current circuit-breakers with overcurrent protection (RCBOs)

The effective choice The benefits of a product with the highest quality standards

Residual current devices

Residual Current Circuit-breaker (RCCB) FH 200 Series

and other modular devices for low voltage installation

Maximum safety and easy installation

ABB STOTZ-KONTAKT GmbH

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

Technical catalogue. System pro M. Residual current devices 2CSC420001D0201

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

Miniature circuit-breaker (MCB) SH200M Series

New System pro M compact All that you need. 2CSC004011B0201

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

RCBOs - Residual current circuit breakers with integral overcurrent protection KZS

W Datasheet: Residual current circuit breaker, series PRIORI, 10kA, Typ B

NEW TX³ RANGE PROTECTION YOU CAN RELY ON

Btdin RCBO 6000A up to 63A (2P)

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

SACE FORMULA New low voltage moulded-case circuit-breakers up to 630 A

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

Domae. The right solution for distribution boards

TX³ RCCBs 2P up to 100 A

BETA Switching Switches and Light Indicators

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

COMPLETE SOLUTIONS FOR POWER PROTECTION

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Selective main circuit breakers S 750 series Technical Data

Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE.

F200 - Ground Fault Equipment Protectors Complete protection of your equipment

COMBINATION CIRCUIT BREAKERS RCBO

Technical Journal September 2012

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

DX³ RCCBs - ID 4P up to 100 A

DX³ 4-pole RCBO 6000 A/10 ka

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

Cat N 3. OVERALL DIMENSIONS

ic60h (6kA) single module combined RCD/MCB units ic60h (10kA) single module combined RCD/MCB units ild residual current circuit breakers idpn N Vigi

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

Residual Current Protective Devices / Arc Fault Detection Devices (AFDDs)

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

MS25, MST25, MS20, MST20

DX³ RCBO 6000 A Phase + Neutral, neutral right side

Low Voltage A GE Power Controls Company. General catalogue

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Electronic circuit breaker EBU10-T

R.C.B.O. SP / 1 module

RESIDUAL CURRENT CIRCUIT BREAKER

Series L9 UL489 Miniature Circuit Breakers

Multi 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com

Residential and light commercial. invicta. panelboards

Simply reliable. ABB Single-phase Transformers. When transformation means safety and control.

MINIATURE CIRCUIT BREAKER

NB1 Miniature Circuit Breaker

Consumer unit solutions to meet the requirements of the new 17th edition amendment 3 regulations

Consumer Switchboards and Circuit Protection Flexible range designed for domestic and commercial installations

QUALITY ASSURANCE & DOCUMENTATION

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

E 90 range of fuse disconnectors and fuseholders Uncompromising performance

W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO

1489-M Circuit Breakers

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

System pro M. Technical catalogue. Miniature circuit-breakers 2CSC400001D0201

DX³ RCBO 6000 / 10 ka Phase + Neutral, neutral on left

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole

Phase + Neutral, neutral on right side

DX³ RCBO 6000A Phase + Neutral, neutral on left

abb.ch ABB Switzerland Ltd. Low Voltage Products Fulachstrasse 150 CH-8201 Schaffhausen Telefon +41 (0) Telefax +41 (0)

xboard safety, reliability effectively combining and performance safety, reliability and performance in commercial and industrial applications

WORKSHOP SPECIFICATIONS

W DATA SHEET: COMBINED FAULT-CURRENT PROTECTIVE SWITCH, SERIES BOLF, 3P+N

Contents. Acti 9 MCBs, RCCB. ic60h circuit breakers (curve B, C, D)... pages 2/2 to 2/4. ic60h and ic60h2 RCB0 10, 30 and 100 ma...

Phase + Neutral, neutral on left side

GROUP TP&N DISTRIBUTION BOARD TYPE B. Distribution boards for modern commercial & industrial installations

RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLFE (6 ka)

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

New DX 3 High rating & breaking capacity

W DATA SHEET: COMBINED RCD/MCB DEVICES BO, 3-POLE

DPX moulded case circuit breakers

Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch

MC FRAME SIZE 1 / UP TO 160A

Wall mounted switchgear

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

Effective discrimination of protective devices

Power systems Protection course

SACE Tmax XT. New low voltage moulded-case circuit-breakers up to 250A.

Selection Guide Motor Control Device Solutions

RX 3 M.C.B A up to 63 A

DX³ RCBO 6000A Phase + Neutral, neutral on right

Working Principle of Earth Leakage Circuit Breaker (ELCB) and Residual Current Device (RCD)

Technical Data. Miniature circuit-breakers for branch circuit protection according to UL 489, CSA C 22.2 No. 5

Technical data. Miniature Circuit Breakers. System pro M. System pro M

Motorized switch-disconnectors OTM 40 to 125 Amperes

MS25, MST25, MS20, MST20

Range 16A to 63A. Sensitivity 30mA, 100mA, 300mA, 500mA. Execution Double Pole, Four Pole. Specification IEC / IS : 2000

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Transcription:

DSE201 Compact design with enhanced protection

The best of safety DSE201 6 ka: the highest level of reliability The 1P+N electronic residual current circuit-breakers with overcurrent protection (RCBOs) DSE201 meet the demand for devices that fully protect modern installations against short-circuit currents, overloads earth fault currents and indirect contacts, providing additional protection against direct contacts (30 ma versions). Each RCBO is fitted with a functional earth wire to guarantee the highest level of safety, even in case of loss of neutral. In only one module width, these electronic residual current circuit-breakers with overcurrent protection offer a technologically advanced and comprehensive range with outstanding features, sizes and tripping characteristics. The 1P+N electronic RCBOs DSE201 share the same profile of the System pro M compact range of modular products, offering a smart retrofit solution for space constrained applications. These electronic RCBO can be installed in countries where the use of 1P+N RCBO with functional earth is consolidated. 2 DSE201. Compact Design with Enhanced Protection

The module for total safety DSE201 6 ka: the highest level of reliability In only one module width, the RCBOs DSE201 combine protection against earthfault currents and overcurrents, providing a breaking capacity of 6 ka. The compact shape of the RCBOs is perfectly integrated with ABB s System pro M compact line of modular products. With the same width as standard MCBs, the RCBOs are fully integrated with ABB s range of Consumer Units and Distribution Boards. Suitable to work from -25 C to +55 C ambient temperatures, the DSE201 RCBOs cover all applications offering, in only one module width, a complete protection of single-phase circuits: short circuit, overload and residual current. The possibility to lock the toggle in ON/OFF positions with a padlock avoids unwanted manipulation of the lines. Installation is made simpler by reduced height (10 cm only) and the availability of two terminals in the bottom part allows the use of both cables and busbars. All operations of installation and removal from busbar and tightening of the terminals are very easy and can be done with a standard insulated screwdriver. Line side terminal is fail-safe type to avoid improper connection, while double clips ensure a secure mounting of the device in any type of consumer unit or distribution board. DSE201. Compact Design with Enhanced Protection 3

The value of quality Made in Italy and attention to details Space for insulated screwdrivers The larger neutral hole allows the use of an insulated screwdriver to tighten the screw of neutral terminals, ensuring maximum operation safety. All versions are equipped with cage type terminals (16mm² load side), with tightening torque of 1.2 Nm. Friendly and protected Fast installation is supported by the two flying leads for neutral cable and functional earth, each integrated in the device, which can be directly connected to the main neutral bar and main earth bar. Product coding All the necessary technical and installation information can be found directly on the device. Product range, tripping characteristics, rated currents, sensitivity, type, breaking capacity, rated voltage, order code, EAN code, electrical scheme, reference standards and many other specifications are laser printed on the front and side of units. Real contact position indicator on toggle Directly connected to the moving contact of the device, it indicates the exact position of the contacts at all times (red: closed contacts, green: open contacts). Anti counterfeiting Each DSE201 is equipped with a RFID tag containing a unique serial number assigned by ABB according to ISO/IEC FCD 15693-3 standard in order to authenticate the product. Through this unique serial number, ABB can easily identify counterfeited products and verify the authenticity of each single device. In control Test button allows the regular check of the functionality of the device. Reduced height Thanks to its reduced height, only 10 cm, DSE201 makes easier wiring operation inside the consumer unit or the distribution board. 4 DSE201. Compact Design with Enhanced Protection

Thanks to the combination of a thermomagnetic circuit breaker and a residual current circuit breaker, the ABB s range DSE201 of 1P+N electronic RCBOs meet all the protection requirements in only one module width. At home or in the office, these devices are essential for the safety of people, utilities and equipment, protecting not only against earth fault residual currents - due to loss of isolation or accidental contact with live parts - but also against overcurrents. The DSE201 RCBOs are particularly compact, flexible and easy to install, either in consumer units or in distribution boards: they offer superior performance and features, and the total integration with ABB s range of modular products. Double slot terminal On the line side, the availability of a terminal with two slots allows to use different types of conductors: one housing is designed for cables up to 25 mm², the other for busbars or cables up to 10 mm². Easy and flexible The double clip eases dismounting even when the unit is installed in a high density system. A single device can be removed from the cluster without disconnecting other units. The same screwdriver used to tighten terminals can also be used to unlock the DIN rail fixing device of the unit. Environmentally friendly The user manual is an integral part of the package. The information have been printed inside the box to make easy the reading and to reduce consumption of paper. DSE201. Compact Design with Enhanced Protection 5

The importance of simplicity Smart solutions for easier and safer installation Due to the compact, flexible design, DSE201 products can be easily installed either in consumer units (mounting on DIN rail) or distribution boards (mounting on chassis). The devices can be supplied with single phase and three phases busbars. LOAD 1 LOAD 2 LOAD 4 Neutral busbar Neutral busbar Earth busbar LOAD 3 neutral wires Example of installation of DSE201 in a consumer unit (DIN rail) in conjunction with other ABB protection devices. LINE (SUPPLY) functional earth wires SD202 F202 S201 S201 DSE201 DSE201 LOAD 1 LOAD 2 LOAD 3 LOAD 4 S201 DSE201 LOAD 5 LOAD 6 LOAD 7 LOAD 8 L1 L2 L3 L1 L1 L2 L3 L1 Example of installation of DSE201 in a distribution board (chassis) in conjunction with other ABB protection devices. L2 L2 L3 L3 functional earth wires neutral busbar Tmax neutral wires incoming neutral LINE (SUPPLY) incoming earth 6 DSE201. Compact Design with Enhanced Protection

The advantage to be flexible Maximum versatility and simplicity A breaking capacity of 6 ka makes the electronic RCBOs suitable for residential and commercial installations. The System pro M compact shape of the DSE201 offers full integration with ABB s range of modular devices. This allows to use the residual current circuit-breakers with overcurrent protection as retrofit solution to renew distribution boards. In only one module width, the residual current circuit breakers with overcurrent protection DSE201 combine the protection against earth-fault currents and overcurrents, and a high breaking capacity of 6 ka. The DSE201 RCBOs are available in A and AC types, with sensitivity of 30 ma and rated currents from 6 to 32A. Type A allows to detect pulsating DC earth fault components generated by modern electronic appliances, such as data communication equipment. DSE201 is also equipped with an overvoltage protection feature in order to monitor the voltage level of the network. When the voltage exceeds a preset threshold (330 V) the DSE201 trips, shielding loads from damage. In this way, more safety is ensured to the installation. DSE201. Compact Design with Enhanced Protection 7

Technical features and overall dimensions Electrical features Standards IEC 61009 Type (wave form of the earth leakage sensed) AC, A Number of poles 1P+N Rated current I n A 6 In 32A Rated sensitivity I Δn ma 30 Rated voltage U e V 230-240 Insulation voltage U i V 500 V AC Overvoltage category III Pollution degree 2 Max. operating voltage V 264 Min. operating voltage for residual current protection V 85 Min. operating voltage of circuit test V 195 Rated frequency Hz 50/60 Rated breaking capacity acc. to IEC 61009 ultimate I cn ka 6 Rated residual breaking capacity I Δm ka 6 Rated impulse withstand voltage (1.2/50) U imp kv 4 kv (test voltage 6,2kV at sea level, 5kV at 2000m) Dielectric test voltage at ind. freq. for 1 min. kv 2.5 kv (50 / 60Hz, 1 min.) Thermomagnetic release - characteristic B: 3 I n I m 5 I n C: 5 I n I m 10 I n Surge current resistance (wave 8/20) A 250 Mechanical data Housing insulation group II, RAL 7035 Toggle insulation group IIIA, black, sealable in ON-OFF positions Contact position indication CPI on toggle (I ON / 0 OFF) Electrical life operations 10000 Mechanical life operations 20000 Protection degree housing IP4X terminals IP2X Shock resistance acc. to IEC/EN 60068-2-27 30g - 2 shocks - 13ms Vibration resistance acc. to IEC/EN 60068-2-6 0,35mm or 5g - 20 cycles at 5 150 5 Hz without load Environmental conditions (damp heat) C/RH 28 cycles with 55 C/90-96% and 25 C/95-100% acc. to IEC/EN 60068-2-30 Reference temperature for setting of thermal element C 30 Ambient temperature (with daily average +35 C) C -25 +55 Storage temperature C -40 +70 8 DSE201. Compact Design with Enhanced Protection

Installation Terminal type top (load side) failsafe cage (shock protected) bottom (line side) failsafe bi-directional cylinder-lift terminal (shock protected) Terminal size for cables load side (top) mm² 16 line side (bottom) mm² 25 Terminal size for busbars load side (top) only for wire connection line side (bottom) mm² 10 (Standard ABB busbar / distribution board system) Tightening torque top (load side) Nm 1.2 bottom (line side) Nm 2.8 Neutral load cable Type low smoke halogen free Lenght mm 750 Section mm² 2.5 up to 20 A; 4 for 25-32 A Color blue Functional earth cable Type low smoke halogen free Lenght mm 750 Section mm² 0,75 Color white Mounting on DIN rail EN 60715 (35 mm) by means of fast clip device in consumer unit Type A according to IEC 60439-1&3, BS EN 60439-1&3, in distribution board Type B according to IEC 60439-1&3, BS EN 60439-1&3. Supply from bottom terminal Dimensions and weight Dimensions (H x D x W) mm 100 x 68,9 x 17,6 Weight g 180 Dimensions 68,9 17,6 58,9 100 Dimensions in mm DSE201. Compact Design with Enhanced Protection 9

Order code DSE201 - Type A DSE201... A30 N. of poles Rated residual current IΔn Rated Current Bbn 8012542 EAN Order details Weight 1 piece [kg] [ma] In [A] Type code Order code B characteristic 1P+N 30 6 399629 2CSR255151R1065 DSE201 B6 A30 0,180 1 10 399728 2CSR255151R1105 DSE201 B10 A30 0,180 1 16 658924 2CSR255151R1165 DSE201 B16 A30 0,180 1 20 658429 2CSR255151R1205 DSE201 B20 A30 0,180 1 25 659921 2CSR255151R1255 DSE201 B25 A30 0,180 1 32 659426 2CSR255151R1325 DSE201 B32 A30 0,180 1 C characteristic 1P+N 30 6 658122 2CSR255151R1064 DSE201 C6 A30 0,180 1 10 659624 2CSR255151R1104 DSE201 C10 A30 0,180 1 16 910923 2CSR255151R1164 DSE201 C16 A30 0,180 1 20 659129 2CSR255151R1204 DSE201 C20 A30 0,180 1 25 658726 2CSR255151R1254 DSE201 C25 A30 0,180 1 32 658221 2CSR255151R1324 DSE201 C32 A30 0,180 1 Pack unit pc. DSE201 - Type AC DSE201... AC30 N. of poles Rated residual current IΔn Rated Current Bbn 8012542 EAN Order details Weight 1 piece [kg] [ma] In [A] Type code Order code B characteristic 1P+N 30 6 659228 2CSR255051R1065 DSE201 B6 AC30 0,180 1 10 658825 2CSR255051R1105 DSE201 B10 AC30 0,180 1 16 658320 2CSR255051R1165 DSE201 B16 AC30 0,180 1 20 659822 2CSR255051R1205 DSE201 B20 AC30 0,180 1 25 659327 2CSR255051R1255 DSE201 B25 AC30 0,180 1 32 658528 2CSR255051R1325 DSE201 B32 AC30 0,180 1 C characteristic 1P+N 30 6 659525 2CSR255051R1064 DSE201 C6 AC30 0,180 1 10 910824 2CSR255051R1104 DSE201 C10 AC30 0,180 1 16 659020 2CSR255051R1164 DSE201 C16 AC30 0,180 1 20 660125 2CSR255051R1204 DSE201 C20 AC30 0,180 1 25 660521 2CSR255051R1254 DSE201 C25 AC30 0,180 1 32 660026 2CSR255051R1324 DSE201 C32 AC30 0,180 1 Pack unit pc. 10 DSE201. Compact Design with Enhanced Protection

Frequently Asked Questions Why is the DSE201 range fitted with two external wires? DSE201 electronic RCBO range is fitted with two external wires to connect neutral and functional earth. Neutral wire (blue wire on photo): In order to ensure residual current protection, the RCBO constantly monitors the flowing current difference between the phase and neutral wires. The neutral must therefore pass into the RCBO. Due to the fact that DSE201 is designed for British Standard distribution boards, that distribute the phases with a fixed busbar system, the neutral connection cannot be on the bottom part of the device. An additional neutral wire is therefore foreseen. Functional earth (white wire): Electronic RCBOs use the line voltage to supply an embedded electronic circuit that manages the residual current protection. In case of loss of neutral the electronic circuit would not be supplied, thus not ensuring RCD protection. In this very uncommon case, the functional earth connection allows the product to work, by using the earth as neutral potential. Even if the risk of loss of neutral is very low, DSE201 range is suited with the functional earth feature in order to guarantee RCD protection in all cases. What happens if I don t connect the functional earth wire? Not connecting the functional earth wire does not affect the standard use of the product unless the neutral connection is interrupted. In this specific case, only thermomagnetic protection is ensured. We warmly recommend connecting the Functional Earth of each device to reach the maximum level of safety. Under which voltages can the DSE201 range be installed? Two voltages values define the working range of the RCBOs: Operating voltage: it indicates the range of voltage under which the RCBOs ensure thermal, magnetic and residual current protections. For DSE201 this range is 85...264V. Test circuit voltage: it indicates the range of voltage under which the testing of the residual current protection (with the test button) can be realized. For DSE201 this range is 204...264 V. The voltage values for which DSE201 can be installed are therefore 204...264V, range in which both RCBO protection and test circuits active. In addition, even in a case of dramatic reduction in voltage, DSE201 would ensure protection down to 85V for a complete safety. What are the advantages of protecting each line with an RCBO instead of a unique RCCB for a group of circuits? Installing an RCBO for each single line guarantees the best continuity of service: in case of residual current fault on a line, only the faulty line turns out of service, maintaining the service on all the others. It is possible to upgrade existing installations, adding RCD protection on each line without additional space, with the electronic RCBOs DSE201. DSE201. Compact Design with Enhanced Protection 11

Contact us ABB SACE A division of ABB S.p.A. Line Protection Devices Viale dell Industria, 18 20010 Vittuone (MI) - Italy www.abb.com/lowvoltage www.abb.com The data and illustrations are not binding. We reserve the right to modify the contents of this document on the basis of technical development of the products, without prior notice. Copyright 2015 ABB. All rights reserved. 2CSC423014B0201-01/2015