VELA INDUSTRIAL INSTALLATION MANUAL

Similar documents
FITTING AND CONNECTION INSTRUCTIONS

SCUTI INSTALLATION INSTRUCTIONS FOR AUTOMATING COUNTER BALANCED DOORS USING THE SCUTI OPERATOR

VERG 24V BARRIER. English

FEATURES AND SPECIFICATIONS

MOUNTING AND CONNECTING INSTRUCTIONS 1. GATE ARRANGEMENT ENGLISH

SLIDE NEW CONTROL BOARD

INSTALLATION MANUAL (cod )

INSTALLATION MANUAL ENGLISH ALPHA 200 ALPHA 330. L C (stroke) 960 mm 1160 mm

JOINT INSTALLATION MANUALS AND SAFETY INFORMATION

Contents. EC DECLARATION OF CONFORMITY FOR MACHINES... p. 10. WARNINGS FOR THE INSTALLER... p. 10

BAYT 980. Oil-hydraulic OIL-HYDRAULIC BARRIER FOR TRAFFIC CONTROL INSTALLATION MANUAL. code 4425 Post with fixing base. POLO 44 - optional -

Installation Manual. Swing Gate System. Leading the way...

IMPORTANT NOTICE FOR THE INSTALLER

HYDRAULIC OPERATOR FOR SWING GATE FULL TANK. SEA S.r.l. Zona Ind. S.Atto TERAMO Italy Tel Fax

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

CONTROL UNIT BIOS2. Manual for installation. Programmable Control board for wings gates.

IRREVERSIBLE OPERATOR FOR SWING GATES AND DOORS

D Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES

Installation manual ASTER AUTOMATION FOR SWING GATES 11_16

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

SARGON S - M - L. All rights reserved INSTALLATION MANUAL

MEKO OPENER FOR RACK-DRIVEN SLIDING MOTOR

TECHNICAL DATA HYDRAULIC UNIT

Type of installation. external motor. underground motor. Leaf max length (m) Leaf max length (m) Max leaf weight (kg) V V V

Installation manual. English. mystrike OPENER FOR RACK-DRIVEN SLIDING MOTOR

Automatic concealed bollards 275 H600 and 275 H800 with pit

CICLÓN ATTUATORE ELETTROMECCANICO IRREVERSIBILE A BRACCIO SNODATO PER CANCELLI A BATTENTE

EC DECLARATION OF CONFORMITY

UNDERGROUND OPERATOR FOR SWINGING GATES. WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack

INSPECTIONS AND MAINTENANCE

Typical Installation Schematic

FORCE SPD 800/1500/2000

INSTRUCTIONS FOR INSTALLATION

Automation systems for swing gates hydraulic

L /2012 rev 0 BISON 30 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC)

L /2013 rev 0 BISON 35 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC) WARNINGS FOR THE INSTALLER

Electromechanical gear motor for sliding gates ACHILLES

INDEX CE DECLARATION OF CONFORMITY FOR MACHINES... 2 WARNINGS FOR THE INSTALLER DESCRIPTION AND TECHNICAL SPECIFICATIONS...

Instructions manual. Below ground oil-hydraulic operator for swinging gates. pages 17-32

MASTIFF 300/300M SWING GATE OPENER USER MANUAL

ARACHNE 230V 24V- 12V

BULL 424 ESA BULL 624 ESA

Ditec LUXO Swing gates automation (Original instruction)

L /2012 rev 0 BISON 45 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

with leaves up to 2 m Kg

Automation Swing Gate Opener

24 V ENCODER SAFE VERSATILE SETTING. Ditec Qik Automatic barriers for passages up to 7.6 m.

EC DECLARATION OF CONFORMITY FOR MACHINES WARNINGS FOR THE INSTALLER

SLIDE & OL USER'S AND INSTALLER'S MANUAL V1.0 REV. 06/2017

FITTING AND CONNECTION INSTRUCTIONS

GROUND GROUND - ( ) Interrati elettromeccanici ISTRUZIONI PER L INSTALLAZIONE. Electromechanical underground INSTRUCTIONS FOR INSTALLATIONS

GB Instructions Manual

TOONA 5 HS. Quick manoeuvres: 90 opening in about 16* seconds.

Owner s Manual. For SOLAR BOOM GATE. Model: CA-5000 SOLAR

BIG Series. D_MNL0BIG Rev.18. IT - Istruzioni originali

Cross Automations for sliding gates

BISON 20 OM BISON 25 OTI

BARRY BARRIER GATE AUTOMATION

Oil-hydraulic operator for swinging gates

AUTOMATION SYSTEM FOR SWING GATES FROG SERIES INSTALLATION MANUAL SUPERFROG

E R A I GATE AUTOMATION DIVISION

Hansa. Sliding Gate. Operators. 10 NiceHansa Catalogue NiceHansa Catalogue

IGLOO IGLOO EASY INSTRUCTION MANUAL

NYOTA 115. Electro-mechanical sliding gate operator. Instruction manual

kinggates collection

dynamos Automation for sliding gates up to 1000 Kg

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

NY 55 Mall Drive, Commack, NY LA Earl St, Torrance CA 90503

CE DECLARATION OF MACHINE CONFORMITY

INSTALLATION MANUAL ACE. Gearmotor for swing gates 01_17

1-24. Oil-hydraulic. Oil-hydraulic road barrier for traffic control from 3 to 8 metres

EL5600 Series Electric Linear Actuators Installation and Maintenance Instructions

Ditec PWR25H/35H Automation for hinged gates

ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS

B.M.P. DOORS LTD INDUSTRIAL RAPID DOORS

Recommended control units: Mindy A824/110. Aluminium Nice release: user-friendly, effortless, sturdy. Flashing light. Digital or key switches

SUBWING 700 USER S AND INSTALLER S MANUAL V1.0 REV. 04/2017

IN-GROUND OPERATOR FOR SWING GATES FROG SERIES INSTALLATION MANUAL FROG-A 230V

TRAFFIC BARRIERS COST EFFECTIVE BARRIER SOLUTIONS

INSTRUCTION INVERTER COMPACT FOR SLIDING GATES /R0 10/11/2017

Automatic concealed bollards 275 H600 and 275 H800 Control station

Single foot switches PX and PA series

TRAFFI BARRIE COST EFFECTIVE BARRIER SOLUTIONS TRAFFIC BARRIERS

MOTOR REDUCER 120 V~ FOR SLIDING GATES

MOTOR. The electric motor. DC - direct current voltage.

so increased accessibility

Clamping and drive module

Ditec PWR Automation system for swing gates with wings up to 5 metres

CHECKING AND MAINTENANCE:

PW320/PW330 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL. Flashing Light. Push Button. Control box. Gate 2.

SWING GATE OPENERS 24V DC GEAR MOTOR

INSTALLATION AND OWNER S MANUAL MODEL ASW Actuator Swing Gate Operator

IP2160 EN. Ditec NEOS Sliding Gates. Technical Manual. (Original instructions)

1 GENERAL SAFETY PRECAUTIONS

Ditec QIK80EH Electromechanical barrier. IP2085EN Technical Manual. (Original instructions)

Model Specifications Code Price FOTOSWITCH

SLIDING GATE OPENER USER MANUAL

Ditec PWR50H/HV/HR Automation for swing gates

Transcription:

GB English VELA INDUSTRIAL INSTALLATION MANUAL BARRIER Mod.: '11701005' 5mt DX; 11701020' 5mt SX; 11701010 6mt DX; 11701025' 6mt SX; 11701015' 7mt DX; 11701030' 7mt SX; 11701035' 7,5mt DX; 11701040 7,5mt SX SEA s.r.l. is glad to congratulate and thank you for choosing our product. Your choice will allow you to understand how our factory, according to studies, research and above all the needs of our clients, wants to gather technology, reliability and safety together keeping in mind use and installation easiness. General characteristics Vela Industrial is an hydraulic automation for big carriage entrances (5, 6, 7 and 7.5 m). The places for fitting are multiple; Vela Industrial is ideal for camp entrances, hospitals, yards, private roads, port and airport entrances, public parkings with half-intensive working cycles. It is provided with an anti-crush device that ensures a strength not higher than 15 Kg on the beam so to ensure people and things against accidents. An accurate slowing down system guarantees the total control of the momentum strength. The manual release makes the beam independent from the hydraulic unit so to allow the manual closing and opening. The automation is constitued by: 1 Vela Industrial case which protects all mechanic and electric devices from atmospheric agents. It is made by a steel sheet which is processed with cathaphoresis and epossidic dust painting. On request SEA provides the inox steel case. 2 Balancing spring which is available in 4 different sizes so to accomplish with the four beam length (See spring tab.) 3 GATE 1 electronic control unit; an advanced device which allows for the programming and control of all working and safety systems. 4 Hydraulic unit with manual release for the manual opening of the beam in case of damages and two screws for couple adjustment. 5 Double effect hydraulic piston which gives movement to the beam by the beam balance assembly. 6 Yoke which holds the beam; completely steel built, processed like the case. 7 Beam in extruded aluminium, available in four sizes: 4,55, 5,55, 6,55, 7,05 m. 8 Mounting plate built with steel sheet coated with zinc. 7 9 6 Name of the most important parts: 1 4 5 1 Vela Industrial Series case 2 Balancing spring 3 GATE 1 Electronic Control Unit 4 Hydraulic pump unit 5 Piston 6 Yoke 7 Aluminium beam 8 Vela Industrial mounting plate 9 Beam balance assembly 2 3 8

Technical data Voltage supply Absorbed current Motor power Motor revolutions Operating temperature Thermal cut out Pump rating Opening time Protection class Working logics Manual release Use frequency : 230 Vac ± 5% - 50/60 Hz single phase : 1.1 A : 230 W : 1400 RPM/min. : -20 + 55C : 130 C : 2 L./min. : 12 s : IP 55 : Autom. Semi-autom. Dead-man : Hydraulic : 50% Barrier Length L (m) 5 6 7 7,5 BEAM TABEL Beam Length L1 (m) 4,55 5,55 6,55 7,05 CONTOUR ALUMINIUM BEAM Spring (mm) 10,5 11 12 12B 100 Spring code 66400005 66400010 66400015 66400020 Sp. 3 mm 50 L1 Dimensions: L 1) Position of spring and piston FITTING INSTRUCTIONS Right hand closing barrier Left hand closing barrier The versatile barrier you are going to install allows for left or right closing according to requirements. To make sure that the barrier closes your desired side open the carter and check that the piston is on the side you like. Ex. With right hand piston the closing is on the right (Fig 1 and 2). If the barrier provided does not close your desired side you can invert it following the instructions we are going to provide. Fig.1 Fig.2

Example: Barrier with left closing (fig, 2) Necessity of right closing (fig1) - Remove spring and piston by unscrewing the bolts shown in Fig.3 - Position the piston on the right hand side of the case (where the spring was fixed) and thighten the fixing bolts. - Position the spring on the left hand side (where the piston was fixed). *The spring is fixed (in the lower part) on a support that in case of a spring/piston switch must be moved with the same spring. The fixing screw is placed behind the two spring tension adjusting bolts. Spring fixing screws * Spring tensioning bolt Spring support Piston fixing screws Fig. 3 2) Mounting plate fixing - Dig a hole 800x600x400 0 - Widen the foundation plate clamps at 60 (Fig. 4) - Fill the hole with R425 concrete and place the foundation plate as in Fig. 4. - Level the plate with care. *The plate has got a central hole for electric wiring so before filling the hole with concrete put an elettric wire sheathing on the hole. Concrete 4 0 0 Vire sheating C l a m p s 6 0~ 800 Fondation plate to be levelled Fig. 4 3) Fixing the column on the fondation plate - Place the column so that the holes at the base correspond to the screws that emerge from the foundation plate. - Make sure that the wire sheathing is fixed on the big central hole at the base of the column. - Tighten the column to the foundation plate screwing the provided nuts and bolts with care. Fixing nuts & bolts Hole for wire sheathing Fig. 5

4) Oil Filler plug When the barrier has been bolted down to the ground remove the oil reservoir transport plug from the upper part of the hydraulic pump unit (fig.6) and replace it for the breather plug supplied with the system. 5) Mounting the yoke and beam - Insert one half of the beam yoke onto the splined shaft vertically and fix it in place by using the bolt and washer supplied (Fig. 6). - Turn the manual release valve anti-clockwise (detail Fig.6). - Rotate the half yoke to the horizontal position and re-lock the manual release (turn clockwise). - Insert the beam into the already installed half of the beam yoke; install the second beam yoke as you did for the first one. - Fix the beam in the beam yoke using the 6 nuts and bolts supplied. Half yoke Nuts and bolts for beam fixing Beam Splined shaft Oil filler plug to be replaced by the breather cork before working Hydraulic pump Hydraulic pump release Fig. 7 Fig. 6

6) Balancing the spring - Turn the manual release valve anti-clockwise to release the hydraulic locking so that the beam can be opened and closed manually. - Lift the beam to an angle of approximately 45 degrees. - Tight or untight the spring adjusting bolt locknut so that the spring reaches a balance point with the 0 beam at 45 (Fig 8). If the beam is correctly balanced it should stay stoptped in position (Fig.8). - After balancing fix the spring adjusting bolt locknut with the bolt and block the hydraulic unit. 7) Slow down adjustment: HYDRAULIC Hydraulic pump unit 45 ~ 45 ~ Spring tension adjusting bolt 15 Fig. 8 Spring bolt locknut Hydraulic pump manual release Pressure adjusting valves 8) Barrier power supply You can now feed the barrier with 220V 50/60 Hz power supply. Check wiring the connectors (paragraph 12) for more details. 9) Force adjustment If necessary the piston force can be adjusted by the two adjusting screws (grey and yellow) placed on the front lower place of the hydraulic pump unit (Fig. 9). *The automation is adjusted at 15 Kg force ex works so to guarantee the anti-crush safety. We recommend to adjust it only in case of necessity. Fig. 9

Spring balance lever Limit switch adjusting screws 10) Levelling the beam This manoeuvre must be done only if at the end stroke the beam is not perfectly horizontal in closing or vertical in opening. - Unlock the hydraulic unit by the release screw so that the beam opens and closes manually. - Release the end stroke screws unscrewing the lock nuts on the beam balance assembly (Fig.10). - Screw or unscrew the end stroke screws so that the beam stays perfectly vertical in opening and perfectly horizontal in closing (Fig.10). - After levelling, fix the end stroke by tightening the lock nuts on the beam balance assembly and block the hydraulic unit. Fig. 10 Lock nuts 11) Wiring In Fig. 11 you find the wiring necessary for the barrier installation. The two numbers placed nearby the electrical cables show their quantity and section. 5 6 4 2 7 1 3 1) Vela Industrial electronic control unit 2) Photocell (receiver) 3) Photocell (transmitter) 4) Key switch 5) Radio receiver 6) Warning light 7) Push button board 8) Differential switch 2x 1 4x1 3x1.5 2x1 2x1 3x1 8

AERI AL NEGATIVE 24 V dc P h ot oc ell Limit swit c h o p e n ing L imi t s wi tch c lo sing S T A R T Comm o n Au x ili a ry Inpu t Cosng l i ENCO D ER Ope ni ng S T O P Phase NE G AT I VE Gr o und NEGAT IVE Neutral Sistemi elettronici 12) Connectors connection The electronic control unit is located inside the box. The panel controls all the device functions. It is technologically advanced and you will choose the logic function that suits you most. CN3 1 2 3 4 5 6 7 8 9 10 1112 1314 15 24 V War n ing ligh t 2 4 V T X Ph o toc e l l Ou tp ut 24Vdc A u xiliary CN1 DIP ON ON = Function active 1 2 3 1 2 3 4 5 6 7 8 9 10 11 12 Operating logic Auxiliary input configuration Pre-flashing Automatic closing Photocell autotest Encoder activation Soft start Brake (slow-down) Leaf locking Closing direction 1 2 3 4 5 6 7 ~ M CN2 Capa cito r 220V F la s hi ng lamp

WARNING The electric installation and the working logic choice must be done according to the existing laws. A 16A - 0,030A differential switch must be incorporated into the source of the operators main electrical supply and the entire system properly earth bonded. Keep the power cables (motors, power supply) and the control ones (push buttons, photocells, radio etc.) separated. You can use two different sheaths to avoid interference. Note: Use cable clips and/or duct/box pipes fitting close to the control panel box so to protect the interconnection cables against pulling efforts. INTENDED USE The Vela industrial has been designed to be solely used to automate barriers. SPARE PARTS To obtain spare parts contact: SEA s.r.l. ZONA Ind.le, 64020 S.ATTO Teramo Italia. SAFETY AND ENVIRONMENTAL COMPATIBILITY We recommend not to spoil the environment with product and circuit packing material. CONFORMITY REQUIREMENTS The VELA IND. oprerator conforms to the following: 89/392/E (Machine Directive) 89/336/E (Electromagnetic Compatibility) 73/23/EC (Electric Safety) STORAGE STORAGE TEMPERATURES T min T max Humidity min Humidity max -40 C +80 C 5% no condensation 90% no condensation When being transported this product must be properly packaged and handled with care. MAINTENAN AND OUT OF SERVI The decommission and maintenance of this unit must only be carried out by specialised and authorised personnel. LIMIT OF GUARANTEE Vela industrial is guaranteed for a period of 24 months. The guarantee period starts from the date stamp printed on the unit. The guarantee will be void if the unit has been incorrectly installed, not used for the purpose intended, tampered with or modified in any way. The validity of this guarantee only extends to the original purchaser of the unit. NOTE: THE MANUFACTURER CAN NOT BE DEEMED RESPONSIBLE FOR ANY DAMAGE OR INJURY CAUSED BY IMPROPER USE OF THIS PRODUCT. SEA reserves the right to modify or adjust the products and information provided in this manual with no obligation to notice.