Protective Link Expulsion Fuse Type Prolink, Oil Immersed, PTAP-APR925 IZUA Technical Guide 15 kv, 23 kv, & 35 kv

Similar documents
Dry Well Cannister Type CLT, OIL Immersed PTAP-AFH926. Technical Guide Load-break, Dead-break

DO-III Fuse Holder TPL , May 2000, Page 1 of 4. General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder. ABB Inc.

Load Break Switch Type LBOR-II, Oil Immersed PTAT-LIR975 IZUA Technical Guide Nut Mount Weld Mount

LV Bushing Oil to Air Dry Insulation PTAB-SLV832

CSP Circuit Breaker Three Phase

OVERALL LENGTH (B) " ( mm) " ( mm) " ( mm) " ( mm)

K-Limiter high ampere Companion II fuse

Fusing Equipment. Kearney Fuse Links. general. Internal Construction. tin element

Figure 1. Non-removable buttonhead Edison Links. TABLE 1 Edison Link Fuse Designs. System Fuse Ampere Rating Type Rating

ABB Power T&D Company Inc. General Information: DT-100 DT-150 DV-100 DV-150. De-energized Switches TPL , July 1999, Page 1 of 4

Kearney fuse links. Technical Data General. Effective March 2014 Supersedes December 2013

K-SEC 030. Fusing Equipment. Kearney Fuse Links GENERAL INTERNAL CONSTRUCTION SINGLE TIN ELEMENT

Kearney fuse links. Technical Data General. Effective December 2013 Supersedes November 2009

Technical Specification For Outdoor Substation Harmonic Filter Banks

PROTECTION AND CONTROL

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

X-Limiter full-range current-limiting fuse

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Design Tests for the 38.0 kv ELSP Current-limiting Fuse per ANSI/IEEE C

Product Selection Guide

EE 741 Over-voltage and Overcurrent. Spring 2014

A. Submit manufacturer's literature and technical data before starting work.

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

Companion II 8.3kV, 17.2kV and 23kV 12K - 40K Backup Fuses

www. ElectricalPartManuals. com CPL Station Arrester Controlled Protective Level Page 1 Indoor-Outdoor Altitude 0-10,000 feet KV

CMU medium voltage power fuses

Fusing Equipment. Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly GENERAL INSTALLATION

26.3. Power Breakers, Contactors and Fuses. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents.

Recommended Procedures

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

Type DTU De-energized Tap Changer Application, Installation & Selection Guide. IL A Instruction Leaflet Page 1 September, 2003

Figure 1. Two and Three-phase MagneX.

NX indoor current-limiting fuses

3.5. Current Limiting Fuses. Contents. CLPT and NCLPT Type Fuses. CLPT and NCLPT Type Fuses

Outdoor Distribution (15 kv through 25 kv) S&C Fault Tamer Fuse Limiter

S&C Fault Tamer Fuse Limiter. Outdoor Distribution (15 kv through 25 kv)

8.3kV, 9.9kV, 15.5kV, 17.2kV and 23kV Cooper ELSP Backup Fuses Testing per C

FX Full-Range Current-Limiting Fuse

Molded Current-Limiting Fuse

COOPER POWER SERIES. K-Limiter back-up current-limiting fuse installation instructions. Fusing Equipment MN132010EN

Fusing Equipment. Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly GENERAL INSTALLATION

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

General Purpose US Fuses

Mica Element Support. Compacted Quartz Sand. Length B

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

SURGE DURABILITY AND IMPROVED TRANSFORMER PROTECTION

S&C Manual PME Pad-Mounted Gear

SWITCHGEAR DIVISION PRODUCT PROFILES

Secondaries. arc flash note Introduction. By Mike Lang, engineer and. Services Supervisor

your Green Power WIND POWER SOLUTIONS only Greener

Subject: Trans-Guard EX Full-Range Current-Limiting Capacitor Fuses Date: 4/10/09 File: PCUP _EX

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A

2.7. Expulsion Fuses. Contents. RBA/RDB Type Fuses (Including Superseded BA Fuses) RBA/RDB Type Fuses (Including Superseded BA Fuses)

Power Fuses. > Power Fuses > BPA & HPA kv AMPs

Medium Voltage Metal-Enclosed Switches

Figure 1. ELSG Current-Limiting fuses. TABLE 1 Maximum Interrupting Current (rms symmetrical) INSTALLATION

Table 1.-Elemsa code and characteristics of Type K fuse links (Fast).

ELF -LR current-limiting fuse

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

3.2. Current Limiting Fuses. Contents

Medium Voltage Fuses

2.7. Expulsion Fuses. Contents. RBA/RDB Type Fuses (Including Superseded BA Fuses) RBA/RDB Type Fuses (Including Superseded BA Fuses)

38 kv Bay-O-Net Cartridge and Fuse Assemblies Certified Test Report

Visual comparison of Plain & Hazy PP Film

Edison modular fuse, vault application products

RBA Catalog Numbers and Information

3.6. Current Limiting Fuses. Contents. ACLS, BCLS, CLS, HCLS and NCLS Type Fuses. ACLS, BCLS, CLS, HCLS and NCLS Type Fuses

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

Engineering Dependable Protection

Medium Voltage Metal-Enclosed Switches

Power Quality and Protective Device Coordination: Problems & Solutions Part 1 Undersizing of Utility Main Service Transformers

www. ElectricalPartManuals. com Engineering Dependable Protection

www. ElectricalPartManuals. com Instructions for Load Break Air Switch, Type LBF, for Power Centers

Shippensburg University

Expulsion Fuses. 2.2 Fuse Selection. 2.3 Application. 2.4 BA Type Fuses. 2.5 DBA Type Fuses. 2.6 DBU Type Fuses. 2.7 RBA and RDB Type Fuses

Technical Specification for Pole Mounted Capacitor Rack

Boric Acid Fuse Links

BUSSMANN. 8.3kV E-Rated SERIES. Medium voltage fuses for feeder circuit, switchgear and transformer. protection. Technical Data 10352

Selection Guide. HHD-BPT, DIN Style, Current-Limiting, Back-Up, Potential Transformer Protection

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT

Chapter 6 Generator-Voltage System

SafeGear TM Motor Control Center Arc resistant metal-clad construction

Elastimold & Hi-Tech Fuse Products

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003

Equipment Protection. Transformers 600V or Less

Appendix C. Interval Every 2 Year. Functional Test Weekly Monthly Quarterly. Semi. Every 3. Engineering Studies

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

FEBRUARY 14, 2017 Elastimold Solid dielectric switchgear customer presentation

Selection Guide S&C ELECTRIC COMPANY. For Transformer-Primary Fuses in Medium- and High-Voltage

25 kv class fused loadbreak elbow connector

Specifications. S&C Alduti-Rupter Switches with Power Fuses Outdoor Distribution (14.4 kv through 46 kv)

Oil Circuit Breakers

SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin

FUSES. Safety through quality

Fuse Link Designation

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Underground Distribution Switchgear

Transcription:

Protective Link Expulsion Fuse Type Prolink, Oil Immersed, PTAP-APR925 IZUA 5670-100 Technical Guide 15 kv, 23 kv, & 35 kv

General Description The Protective link is an oil immersed, expulsion type, fuse assembly for use in the high voltage circuit of a distribution transformer. Used in coordination with the CSP circuit breaker, the protective link s function is to disconnect a defective transformer from the feeder circuit, and to limit the severity of the damage to the transformer in case of an internal fault. The link consists of a fuse wire element contained within a hard fiber tube. The wire is welded to a top electrode at one end and crimped to a bottom electrode or welded directly to the cable lead at the other end. Protective links are available in a wide variety of fuse sizes and kv classes for proper coordination with CSP circuit breakers. Application Information Fuse Curve Selection When designing a CSP protection scheme, the secondary CSP circuit breaker is selected first. After the secondary circuit breaker is selected, the protective link is chosen so that proper coordination between the primary side protective link and the secondary side circuit breaker is achieved. The simplest way to determine if proper coordination has been achieved is to compare the time versus current characteristics curves (TCC curves) of both devices. Coordination is acceptable when, Figure 1: Schematic Diagram of CSP Transformer Table 1: Interruption Rating 2 1 Interrupting Rating Application Voltage (rms symmetrical Amperes) 2,400 5,000 4,800 4,800 7,200 3,500 12,000 3,000 14,400 2,500 23,000 1,200 34,500 1,200 1 Application Voltage listed as: Single Phase: Line to Ground Three Phase: Line to Line 2 Interruption ratings are based on a well constructed round tank distribution transformer. Ratings will generally be greater for pad mounted distribution transformers because of the rectangular tank's ability to absorb a considerable ammount of energy during high current fault interruption. for all values of secondary fault current, the circuit breaker will clear the fault before the protective link melts. The protective links are produced in a wide range of fuse sizes which are described on curve drawing 697700 for minimum melt characteristics and curve drawing 735701 for average clearing characteristics. Circuit Connection The protective link is connected between the primary winding and high voltage bushing. In a transformer with a single high voltage bushing (where one end of the primary winding is connected to the ground), one protective link per transformer is used. In a transformer with two high voltage bushings, two protective links are used. A typical CSP transformer schematic diagram is shown in Figure 1. A jack bolt (style number 240A394H01 ordered separate) fits into the 0.25 x 28 thread in the top terminal of the protective link and may be used to make up the top connection to the link. In lieu of this bolt, any standard 0.25 diameter x 28 threads per inch x 0.38 thread length bolt will work. The lower connection to the protective link is made through the flexible cable lead. The flexible cable lead is specified on the dimension sheets as: number of wire strands - individual wire strand thickness (example 259-0.005 = 259 strands of 0.005 diameter wire). Mounting Information Protective links may be mounted in any orientation as long as the expulsion arc will be under oil during arc interruption. Standard mounting configuration is in a near vertical to vertical 2

position in round tank transformers and horizontal to vertical in pad mounted units. All energized parts of the protective link must be under oil and spaced away from all other energized or grounded parts with sufficient distance to withstand all operating and test voltages. The transformer tank design must be capable of absorbing the arc energy of the protective link through tank venting or other means. The interrupting rating of this device is a function of the tank design and the live part insulation. See the appropriate breaker application manual for coordination with CSP breakers. Mounting Accessories Three different methods may be used to mount Protective Links: a narrow groove flat clip bolted to an insulator, retaining rings and terminal block, or directly mounted to an insulating mounting block. The narrow groove flat clip (75D0426H01) is placed in the small groove around the protective link, the ends are closed together, the mounting bolt is run through the eye ends of the mounting clip, and is bolted to the insulating structure. The bolt holds the clip closed around the protective link, as well as securing the link to the insulating structure. The retaining rings (style number 9820A65H05) fit into two small grooves on the fiber tube body and secures the fuse in the terminal block (style number 584B903H01). This mounting arrangement is shown in Figure 3. The protective link may also be mounted using an insulating block. This mounting scheme is shown in Figure 4. Details Protective Link Figure 3: Block Mounting - 584B903H01 Mounting Hole - bolt to insulating member of transformer superstructure Retaining Clips (above & below) Terminal Block Cable Lead Flat Clip Groove Figure 2: Part Identification and dimensional information for this block may be found on Dimension Sheet 44-889 Pg 13. Link Operation When the fuse wire melts due to a fault current, an arc is established within the fiber tube. The interaction of the arc on the fiber tube s interior wall generates gases, which (in combination with the expulsive action of the protective link) extinguishes the arc rapidly and clears the circuit. Features & Advantages Top Electrode Fiber Tube Cable Lead Multiple Ratings Protective links are manufactured in three voltage classes and up to thirteen different fuse curve variations. The three voltage classes are 15 kv, 23 kv, and 35 kv. These ratings apply to a single phase transformer s line to ground voltage, or a three phase transformer s line to line voltage. For example, a three phase transformer connected to an 11kV system would use the 15kV links and if connected to a 22kV system would use the 23kV links. The various fuse curves are shown on TCC curves 697700 and 735701. 3

Ordering Information Curve Number Current Rating < = 15kV < =23 kv <=35 kv 2 4. 5 592B581G01 779C667G01 345B995G21 3 6. 2 592B581G02 779C667G02 345B995G29 3A 7 592B581G11 779C667G03 345B995G22 4 8. 2 592B581G06 779C667G08 345B995G33 5 11 592B581G03 779C667G04 345B995G23 5A 13 592B581G12 779C667G09 345B995G24 6 16 592B581G04 779C667G05 345B995G28 7 21 592B581G05 779C667G06 345B995G25 7A 24 592B581G13 779C667G33 345B995G34 8 30 592B581G07 779C667G07 345B995G26 9 49 592B581G08 779C667G34 345B995G27 10 71 592B581G09 Contact 345B995G31 11 102 592B581G14 Contact 345B995G32 12 160 592B581G31 Contact 13 230 592B581G32 Contact Contact Contact Printed in USA by Tennessee Industrial Printing Services, Inc. Figure 4: Block Mounted 35kV Protective Link Inc. 1128 S. Cavalier Drive Alamo, TN 38001, USA Telephone: 731-696-5561 Fax: 731-696-5362 www.abb.com Design Tests The protective link assembly has passed a series of design tests which offer verification of the design reliability: 1. Interruption Tests 2. Minimum Melt Tests 3. Safe Transit Test Production Tests In addition to the initial design testing that was performed, the following tests are run on daily production units: 1. Dimension check to verify critical dimensions. 2. Visual inspection to verify assembly process. Warning The misapplication of the protective link constitutes a potential hazard to life & property. Accordingly, the user must exercise due care in utilizing this information to ensure that the protective link is properly applied. IZUA 5670-100en Replaces TPL 44-839, February 2003