Electromagnetic Flow Measurement

Similar documents
Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop.

OPTIFLUX 6000 Technical Datasheet

SENSOR MUT2300. Electromagnetic flowmeter. The electromagnetic flowmeter designed for the toughest applications DS401-1-ENG

MS 2500 FLANGED SENSOR WITH A WIDE RANGE OF FLANGE SIZES. Warranty conditions are available on this website: only in English version

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

SENSOR MUT2300. Electromagnetic flowmeter. The electromagnetic flowmeter designed for the toughest applications DS401-1-USA

SITRANS F M flow sensors 711/A and 711/911E

WATERFLUX 3000 Technical Datasheet

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

Electromagnetic Flow Meter Owner s Manual HARDWARE

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date

Magnetic Inductive Flowmeter EP / UMF2 (B)

LCMass Series Mass Flow Sensor

INSTRUCTIONS SITRANS F M MAGFLO Electromagnetic flowmeter type MAG 1100 FOOD, DN 10 - DN 100

OPTIFLUX 2000 Quick Start

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

유량계전문제조업체. Electro Magnetic FLOWMETER

Electromagnetic Flowmeters. Product Overview.

Magnetic-inductive flow meter for hazardous areas

VERSAFLOW MAG 4000 Quick Start

Electromagnetic flowmeters

OPTIFLUX Electromagnetic Flow Sensor

SENSOR MUT2200EL. Electromagnetic flowmeter. The electromagnetic flowmeter for all applications DS100-6-ENG

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

BATCHFLUX 5500 C Technical Datasheet

Electromagnetic Flow Monitor magphant

Electromagnetic Flow Monitor magphant

E M F. Description. Principle of Operation. Introduction for EMF Series of Electromagnetic Flowmeters

SITRANS P measuring instruments for pressure

MULTICHANNEL ULTRASONIC FLOW METER AFLOWT UF

Field IT Electro-Magnetic Flowmeters Sensors

WATERFLUX 3070 Technical Datasheet

EPS / UMF2. Magnetic Inductive Flowmeter for Conductive Liquids

TEK-F LUX 1400A. Electromagnetic Flowmeter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW

AquaMaster4 Electromagnetic flowmeter flanged sensor

SENSOR MUT2400EL. Electromagnetic flowmeter. The electromagnetic flowmeter designed for food industry DS200-1-ENG

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

INSTALLATION AND OPERATION

ULTRASONIC FLOW SENSOR IFX-M4-01

Electro-Magnetic Flowmeters Sensors MagMaster MFE

Insertion magnetic inductive flowmeter

Ensuring Premium Performance with Foxboro I/A Series Pulsed dc Magnetic Flowmeters

Model 1100 Turbine Flow Meter

INSTRUCTION MANUAL MS 3810

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual

ProcessAutomatic EZ-Mag

ABB Instrumentation. MagMaster MFE Series Electromagnetic Sensors. Specifications. MagMaster - bringing unsurpassed flowmetering performance

FIELD DEVICES - FLOW PSS 1-6F9 A. Product Specifications

CSO/STORMWATER MANAGEMENT. HYDROVEX FluidMid Flow Monitoring & Regulating Station with Siphon (Type G)

OPTIMASS 3000 Technical Datasheet

RUN ACCUM. TOTAL STOP BAT LOW HIGH

Electromagnetic flowmeters for water and seewage

Magnetic Inductive Flow

OPTIMASS 2000 Technical Datasheet

WATERFLUX 3070 Quick Start

Botlek Studiegroep Basics Electro Magnetic Flowmeters

Full Profile Insertion

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been

Liquid Turbine Flow Meter OwnerÊs Manual

Danyal Education (Contact: ) A commitment to teach and nurture. c) sketch a graph of voltage output against time for a simple a.c.

Electromagnetic amplifier Primo Advanced for all detectors

Superstatic 749. Fluidic Oscillation Compact Heat Meter

PROCESSAUTOMATIC MAGNETIC FLOWMETER

Technical Information Proline Promag 10L

Electromagnetic amplifier type ModMAG M10 for all detectors

Fluidic Oscillation Compact Heat Meter

ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products Rev PK KMS501W & KMS502F- TW. Electromagnetic TRADEWASTE Flowmeters FEATURES:

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice

Electromagnetic flowmeter EMKO E

Appendix. Clearance. Skewed profiles. Application Schematics

WATERFLUX 3070 Technical Datasheet

AP Physics B: Ch 20 Magnetism and Ch 21 EM Induction

Motional EMF. F = qvb

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

UniMag DT Series Electromagnetic Flow Tubes

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter

IFX-M4-03 IFX-M4-03_D_E_2017_05_REV.0

Fluidic Oscillation Compact Heat Meter of High-Tech Composite

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application

Continuous level sensor NSK

CHAPTER THREE DC MOTOR OVERVIEW AND MATHEMATICAL MODEL

ELECTROMAGNETIC FLOWMETERS INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Continuous level sensor NSK

MODEL 1100 TURBINE FLOW METER

Volumeter TRZ 03-K PRODUCT INFORMATION. Reliable Measurements of Gas

FLOWX3 F3.60M.S Insertion Magmeter

Flow measurement FlexFlow PF20H Hygienic flow sensor

Model TUR-200D Turbine Flowmeter

Fundamental Training. Flow Con t

Residential Water Meters

STEEMCO Flowmeter for Steam

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2

ISTEC MAGNETIC METERS

Simply a question of better measurement

Electromagnetic Flow Measuring System PROline promag 10 W

Turbine flowmeters Series TM

STUF-280W. Features: Ultrasonic Water Meter, DN15~DN40. Ultrasonic Water Meter DN50~DN600

Unit 8 ~ Learning Guide Name:

MOD. MASTER METER INSTALLATION OPERATION AND MAINTENANCE. PETROL INSTRUMENTS S.r.l APRILIA (LT) - ITALY

ORIMAS Mass Flowmeter

Transcription:

Electromagnetic Flow Measurement

INDEX CERTIFICATION AND COMPLIANCE 3 MEASURING PRINCIPLE 4 MEASURING SYSTEM 5 DIAMETER SELECTION 6 INSTALLATION 7 INLET AND OUTLET 7 MOUNTING POSITION 7 VIBRATIONS 8 AIR VENTING 8 MOUNTING LOCATION AND PARTIALLY FILED PIPES 8 PUMPS INSTALLATIONS 9 INSERTION PROBES 9 WAFER SENSORS 9 GROUNDING 10 IP68 11 CALIBRATION 12 VERIFICATION 12 Isoil Industria is a worldwide leading supplier of electromagnetic flowmeters. On the market since 1958, the company has been concentrating its efforts and expertise through the years towards the evolution of the electromagnetic fl ow-meters technology. It is worldwide recognized and present in all Countries through distributors and agents, and with a branch office in Brasil.

CERTIFICATION AND COMPLIANCE ISOIL INDUSTRIA CERTIFICATIONS Reference UNI EN ISO 9001:2008 OHSAS 18001 : 2007 CH-MI001-07008-01 CH-MI004-08008-02 R49/2006-CH1-09.02 WRAS BS 6920 3A SSI : Sanitary Standards ISOIL INDUSTRIA - ISOMAG PRODUCT LINE COMPLIANCE Reference ISO 4064 UNI EN14154: 2007 EN61010-1:2010 EN61326-1:2006 EN13480-3:2007 2006/95/CE 2004/108/CE CH-MI001-07008-01 CH-MI004-08008-02 Title Quality Management System Occupational Health and Safety Series 2004/22/CE European Measurement Instrument Directive, Annex MI001, Meters for cold water Std. OIML R 49-1/2 MOD. D 2004/22/CE European Measurement Instrument Directive, Annex MI004, Meters for hot water & Heat Meters standard UNI EN 1434/1/2/3/4:2007 MOD. D OIML R49-1/2:2006 Water Meters intended for measurement of cold potable water or hot water Water Regulations Advisory Scheme, Effects on Quality of Water Certification for use of meters in Sanitary Applications Standard : 28-04 Title Measurement of water flow in fully charged closed conduits Meters for cold and hot potable water Specifications, Installations and Testing European Regulation for Water Meters Safety requirements for electrical equipment for measurement, control, and laboratory use European Union s EMC standard for electrical equipment for measurement, control, and laboratory use European Pressure Equipments Directive (PED) 97/23/CE European Low Voltage Directive European Electromagnetic Compatibility Directive 2004/22/CE European Measurement Instrument Directive, Annex MI001, Meters for cold water Std. OIML R 49-1/2 MOD. B 2004/22/CE European Measurement Instrument Directive, Annex MI004, Meters for hot water & Heat Meters standard UNI EN 1434/1/2/3/4:2007 MOD. B 3

ISOMAG METERS The ideal flow-meter for your application ISOMAG is a line of electromagnetic fl ow meters including several electronics (converters) able to energize and read data from a set of sensors (fl anged, wafer, threaded or insertion type). From DN03 to DN 2000 and more Wide range of process connections Battery powered system GSM/GPRS wireless communication High speed converter PID controller Energy meter Sanitary approval MID-MI001 & OIML R49 approvals MID-MI004 (EN1434) approval Flow-meters used in different industries Mag meters are suitable for a high variety of applications, where liquids to be measured have a conductivity of at least 5 μs/cm such as: Agriculture Building automation Chemical&Pharmaceutical Energy Filling Food & Beverage Pulp & Paper Water & Waste Water NRW DMAs MEASURING PRINCIPLE The operating principle of magnetic fl ow-meters is based upon Faraday s Law of electromagnetic induction which states that a voltage will be induced in a conductor moving through a magnetic field. The magnitude of the induced voltage e is directly proportional to the velocity v of the conductor width L, and B being the strength of the magnetic field. This is the formula: e = k B L v Magnetic field coils placed on opposite sides of the pipe generate a magnetic field. As the conductive process liquid moves through the field with average velocity v, electrodes sense the induced voltage. The width of the conductor is represented by the distance between electrodes. An insulating liner prevents the signal from shorting to the pipe wall. The only variable in this application of Faraday s law is the velocity of the conductive liquid v because field strength is controlled constant and electrode spacing is fixed. Therefore, the output voltage e is directly proportional to liquid velocity, resulting in the linear output of the magnetic fl ow-meter. Flowrate Q is calculate as Q = const. e Insertion probes are a valid alternative to full bore meters for use in survey applications such as leakage monitoring and network analysis and in permanent locations where cost or space limitations preclude the use of conventional closed pipe meters. The principle is the same, the lay of Faraday, but the magnetic field in this case is only punctual, while in the full bore case all area is interested. Insertion probes are installed either at 1/8 or 7/8 of the internal diameter of the pipe, where the mean velocity vector passes, or in the middle of the pipe, where the maximum speed vector passes. Pipe must always be full. 4

MEASURING SYSTEM An electromagnetic fl ow-mater is made of a sensor, which is the primary element installed in the pipeline and a converter, which is the secondary element, energizing the coils inside the sensor and detecting the electrical signal. Sensors can be fl anged, fl angeless or insertion type and with different kind of internal liners. The electronic can be mounted on top in compact version, or separated by cables in remote version. A wide variety of converters answers to the request in terms of accuracy, communication protocols and powering needs. SENSORS CONVERTERS CABLES It is recommended to install the connection cables away from, or protect against sources of electromagnetic noise. Allowed cable length according to conductivity level. CONDUCTIVITY (μs/cm) 200 150 100 50 ML110 ML210/ML211/ML212 5 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95100 CABLES LENGHT (m) A distance up to 500 meters is possible by adding a pre-amplifier on top of the sensor. 5

DIAMETER SELECTION Selecting the proper sensor diameter is mandatory to obtain a good result in the measure. The first practical rule is selecting the sensor diameter according to the pipe diameter. However, it is often necessary to increase the flow rate value by reducing the sensor diameter. This might lead to an increase of the cost of the installation which is by the way compensated by the lower cost of the meter. As a recommendation, the velocity of the fluid inside the meter should be: 1 < v < 3 m/s for an optimal working condition; v < 2 m/s with abrasive fluids in order for the liquid not to have high velocity causing possible deamage to the internal liner; v > 2 m/s with coating fluids in order not to incur in deposit of solid parts on the electrodes. The correct balancing of the above elements should help in the selection of the proper sensor diameter. Adapters and pressure loss calculation Nominal diameters and measuring range pressure loss in mbar max. 8 d D 100 8 m/s 7 m/s 6 m/s 10 5 m/s 4 m/s 3 m/s 2 m/s 1 1 m/s 0,5 0,6 0,7 0,8 0,9 ratio of diameters d/d DN mm Minimum Full scale value v=0,4 m/s Maximum Full scale value v=10 m/s 3 0...10 l/h 0...250 l/h 6 0...40 l/h 0...1000 l/h 10 0...120 l/h 0...2800 l/h 15 0...240 l/h 0...6000 l/h 20 0...500 l/h 0...11500 l/h 25 0...0,72 m 3 /h 0...18 m 3 /h 32 0...1,16 m 3 /h 0...29 m 3 /h 40 0...1,80 m 3 /h 0...45 m 3 /h 50 0...2,88 m 3 /h 0...72 m 3 /h 65 0...4,80 m 3 /h 0...120 m 3 /h 80 0...7,20 m 3 /h 0...180 m 3 /h 100 0...11,20 m 3 /h 0...280 m 3 /h 125 0...18,00 m 3 /h 0...450 m 3 /h 150 0...25,60 m 3 /h 0...640 m 3 /h 200 0...45,20 m 3 /h 0...1130 m 3 /h 250 0...70,80 m 3 /h 0...1770 m 3 /h 300 0...100,80 m 3 /h 0...2520 m 3 /h 350 0...138,00 m 3 /h 0...3450 m 3 /h 400 0...180,00 m 3 /h 0...4500 m 3 /h 450 0...228,80 m 3 /h 0...5720 m 3 /h 500 0...284,00 m 3 /h 0...7100 m 3 /h 600 0...408,00 m 3 /h 0...10200 m 3 /h 700 0...560,00 m 3 /h 0...14000 m 3 /h 800 0...720,00 m 3 /h 0...18000 m 3 /h 900 0...920,00 m 3 /h 0...23000 m 3 /h 1000 0...1140,00 m 3 /h 0...28500 m 3 /h 1200 0...1600,00 m 3 /h 0...40000 m 3 /h 1400 0...2200,00 m 3 /h 0...55000 m 3 /h 1600 0...2880,00 m 3 /h 0...72000 m 3 /h 1800 0...3640,00 m 3 /h 0...91000 m 3 /h 2000 0...4520,00 m 3 /h 0...113000 m 3 /h 2400 0...6400,00 m 3 /h 0...160000 m 3 /h 6

INSTALLATION Please note the following instructions to ensure a correct procedure from the unpacking to the correct measurements and in order to avoid damage to the measuring installation. Inspect the cartons carefully for damage or signs of rough handling. Report damage to the carrier and to the local office of the manufacturer. Check the packing list to check if you received completely all that you ordered. Packages may contain soft and hard information material. Look at the device nameplate to ensure that the device is delivered according to your order. Check for the correct supply voltage printed on the nameplate. INLET AND OUTLET 3 DN 2 DN Any mean of turbulence, such as valves, elbows, T-pieces, etc might cause inaccuracies in the meter s reading. The effect of such turbulences varies according to the installation and surrounding conditions and are not predictable. In case of presence of other devices nearby the meter straight pipeline length must be verified according to plant layout and/or international standards reccomendations such as ISO 7145 BS 1042. In spite of the fact that ISOMAG meters have been tested and certified to be able to work also with no upstream and downstream straight DN, the recommendation is to foreseen at least 3 DN in the inlet and 2 x DN in the outlet. MOUNTING POSITION Vertical a) Optimum position for upward flow direction: entrained solids will sink; fatty particles will rise out of range of the measuring electrodes if the fluid stops flowing; pipe will remain always full even if the fluid stops flowing. Horizontal b) install sensor in line with the pipe axis; pipe flange faces must be parallel to each other. 7

VIBRATIONS Avoid vibrations in the pipe. Separate mounting of sensor and converter might help in reducing the negative effect of vibrations on the measuring. Long pipes need mechanical supports to minimize the effect of the vibrations. > 10 m AIR VENTING 2 Air in the pipe may cause, among others: faulty water meter readings; corrosion; acceleration of cavitation. 1 5 m 1 If installed as shown on the left, please ensure a >5 m downward pipe to avoid vacuum 2 Air ventilation point MOUNTING LOCATION AND PARTIALLY FILED PIPES A mandatory requirement for an accurate measurements is that pipes are filled. Therefore the following installation sites have to be avoided: a) In case of installation like in the picture besides: do not mount sensors at the lowest point (solids may accumulate); use a siphon-type installation. b) a) highest point (accumulation of air); b) in front of a free pipe outlet in a downward pipe. The picture on the left shows the alternative installation. h > 2 x DN > 2 x DN In any case ISOMAG meters have an Empty Pipe System which helps in case of such a situation of no water in the pipe. > 3...5 x DN The minimum conductivity of the liquid medium to ensure correct functionality of the empty pipe detection is 20 μs/cm 8

PUMPS INSTALLATIONS A mandatory requirement for an accurate measurements is that pipes are filled. Therefore the following installation sites have to be avoided: Sensors must not be installed on the inlet of pumps. Such installation might create vacuum. INSERTION PROBES Insertion probes follow the same rules as the full bore ones. All requirements specified in the previous paragraphs are still valid also for this type of meters. Install the sensor away from disturbances (curves, T junctions, valves and equipment that protrudes in to the pipe). Pipe must be always full. When installing in vertical pipes, ascending fl ow direction is recommendable. Probes can be installed at 1/8, 1/2 or 7/8 of the internal diameter of the pipe. WAFER SENSORS Place the sensor between fl anges. The studs should be aligned with the markings on the rings that correspond to the fl ange you are using Installation, Studs Nuts and Washers Centering sleeves (optional) Customer-supplied Gasket FLOW Insert the remaining studs, washers and nuts. Tighten to the torque specifications as indicated in the technical data sheet. Do not over tighten the bolts. Otherwise the liner may be damaged. Note: The sensor requires a gasket at each of its connections to adjacent devices or piping. The gasket must be a full face gasket to cover the entire sealing surface of the meter, and the material selected must be compatible with the process fl uid and operating conditions. Metallic or spiral-wound gaskets can damage the liner. Gaskets are required on each side of a grounding ring. 9

GROUNDING Proper grounding of magnetic fl ow-meters (in accordance with the applicable safety regulations) is important for an accurate and reliable measurement performance. In addition to safety reasons, the EMF must be grounded also for metrological reasons. The signal voltage induced in the electrodes has a value of approximately one millivolt or less. The signal converter can only process such small signals without interference if this voltage is referred to a fixed potential (ground). Grounding in pipelines that are electrically conductive inside (e.g. stainless steel pipelines) The EMF is electrically connected to the pipeline in an equipotential bonding sense. The pipeline is grounded, thus providing a fixed reference potential for the process liquid and the signal voltage. SEALING GASKET Grounding in pipelines with electrically insulating inside walls METALLIC RINGS SEALING GASKET In pipelines made of plastics or concrete, or those which have an insulating lining or coating inside, the process liquid needs to be grounded by additional measures. For this purpose, metal grounding rings are normally used whose inside face is in contact with the process liquid and which are fitted and grounded between the pipe and fl owmeter fl anges. Grounding in pipelines with cathodic protection METALLIC RINGS For pipelines with cathodic protection meters must be correctly grounded and isolated from pipeline using insulating bushes on both to avoid risk of making cathode protection ineffective. INSULATING BUSH Grounding rings are often used in pipes to ground unwanted electrical signals. In flow measurement, grounding rings are commonly installed upstream and downstream of magnetic flow meters. Grounding rings provide an electrical grounding pathway around the flow meter to safely eliminate accumulated voltage or induced current in the flowing conductive fluid. Additionally grounding rings act as a protective wear plate to prevent erosion of the leading edge of the flow meter liner. Grounding can also be achieved by using additional ground electrodes in the EMF, which in some cases are less expensive than grounding rings. 10

GROUNDING OF INSERTION PROBES Insertion probes requirements are the same as full bore meters, therefore they require sensor and liquid to be at the same potential. Always connect both sensor and converter to a proper ground. GROUNDING OF THE ELECTRONICS For the correct operation of the meter both sensor and the converter are required to be grounded. M3 L (+) N ( ) IP68 IP s l (i) s = solids, l = liquids and i = impact (optional) First Index - Foreign Bodies Protection, Solids Index Protection against Human/Tool Contact Protection against solid objects (foreign bodies) 0 No special protection 1 Back of hand, Fist Large foreign bodies, >50mm 2 Finger Medium-sized foreign bodies, >12 3 Tools and wires etc with a thick. >2.5mm Small foreign bodies, >2.5mm 4 Tools and wires etc with a thick. >1mm Granular foreign bodies, >1mm 5 Complete protection, (limited ingress permitted) 6 Complete protection Dust-proof Dust protected; dust deposits are permitted, but their volume must not affect the function of the unit. The term protection class generally indicates the type of protector of a device or the internal workings of a device against direct contact and against the infiltration of foreign bodies, such as objects, dust or water. The resistance to stress arising from prevailing working conditions is defined using international protection (IP) classes. These protection classes are, in turn, indicated in IP standards (DIN EN 60529), whereby a combination of two digits specifies the level of protection. The first digit indicates the level of resistance to foreign bodies and dust, the second digit the level of resistance to water infiltration. Second Index - Water Protection, Liquids Index Protection against water Protection from condition 0 No special protection 1 Water dripping/falling vertically Condensation/Light rain 2 Water sprayed at an angle Light rain with wind (up to 15º degrees from the vertical) 3 Spray water Heavy rainstorm (any direction up to 60º degrees from the vertical) 4 Spray water from all directions, Splashing (limited ingress permitted) 5 Low pressure water jets from all directions, (limited ingress permitted) Hose down, residential 6 High pressure jets from all directions, (limited ingress permitted) Hose down, commercial. eg. Ship decks 7 Temporary immersion, 15 cm to 1m Immersion in tank 8 Permanent Immersion, under pressure For use on Titanic recovery vehicle A higher value of the relevant digit (first digit 0-6, second digit 0-8) indicates a higher level of protection. IP68 protection grade means that the instrument has complete protection against dust infiltration (first digit 6) and it is suitable for continuous immersion in water. As a standard, immersion is usually guaranteed up to 1 meter. However, higher depths are possible. 11

CALIBRATION The only way to properly calibrate any meter is using either a Master Meter or a Volumetric Prover or a Weigh Scale. For this purpose, you mainly need to refer to the manufacturer or to an authorized laboratory. Anyhow, this might result unpractical and in any case need to stop the line, remove the meter and ship to calibration place. Currently, time intervals for re-calibration might be different country by country according to local rules / laws; you might need to refer to your local authorities to check if such a kind of requirements is regulated in your own country. In addition to local rules, where the meter generates revenues (water billing, in example) it might be interest of the owner to have the meters inspected at defined intervals. 02/2013 gandini-rendina.com VERIFICATION - Sensor Coils Resistance Impedance Electrodes Insulation Current to coils - Converter Digital Impulse outputs Frequency Easier to perform and good practice as preventive maintenance plan, in-situ verification can be performed on regular basis without interrupting the service. Electromagnetic Flow Meters are electronic equipments with linear operation. As far as main vital parameters remain unchanged in time, the meter will reasonably maintain original operating performances. Analog outputs 4/20mA Communication ports In some countries, a full verification is requested to be performed every second year. Between two full verifications, electronics only are requested to be verified by fl ow simulators. ISOCAL Verificator ISOCHECK Flow Simulator 12 Cinisello B. - Mi (Italy) - Tel. +39 02 66027.1 - sales@isoil.it - www.isomag.eu The solutions that count