Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

Similar documents
GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

Go Power! Manual. GP-SW1500 Inverter. Table of Contents. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4

V 2.0 DC TO AC POWER INVERTER PWRINV500012W PWRINV500024W PWRINV500036W PWRINV500048W. Instruction Manual

Pure Sine Wave Inverter GP-HS1500. Owner s Manual

GSL Electronics Modified Sine Wave Power Inverters

S150,S300 Series Pure Sine Wave Inverter User s Manual

Power InverterTM Watt. Continuous. User's Manual. WAGAN Corp. Limited Warranty Registration Form. Item no

USER MANUAL FOR 2000 WATTS POWER INVERTER USER S MANUAL--Read before operating this equipment

DC TO AC POWER INVERTER

Go Power! Manual. GP-Smart Charger

PureWatts Elite Power Inverter. Instruction Manual 1000 / 2000 WATTS

ATD WATT INVERTER

OWNER S MANUAL. Please read installation and operation instruction before using this Power inverter.

Inverter User Manual

Pure Sine Wave Inverter User Manual

installation kit Ask your retailer!

S600,S600R Series Pure Sine Wave Inverter User s Manual

HG PI2000. How Your HG PI2000 Power Inverter Works Watt Power Inverter. Nothing comes close to a Cobra TM

HQST 500W (12V) HQST 1000W (12V) Modified Sine Wave Inverter. User Manual

ATD WATT INVERTER

TABLE OF CONTENTS. 300 W Mobile Power Outlet SAVE THESE INSTRUCTIONS!

3000W POWER INVERTER. User Manual

PROwatt 150 DC to AC Power Inverter. Owner s Guide

CHEROKEE. DC To AC POWER INVERTER USERS MANUAL

Owner s Guide. DC TO AC Power Inverter

Owner Manual POWER INVERTERS E1000 / E1500 / E2000 / E2000GF (GFCI) HD1200 / HD1800 / HD2500 HDi1800 / HDi3000

800 WATT POWER INVERTER

O W N E R ' S M A N U A L

12VDC TO 230VAC INVERTERS

800 WATT POWER INVERTER

Xantrex Inverter 300. Owner s Guide

S600,S600R Series Pure Sine Wave Inverter User s Manual

Raptor USA

1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY

PureSine 150/300 Pure Sine Wave Inverter User s Manual

DC TO AC POWER INVERTER PWRIC150012W INSTRUCTION MANUAL

Table of Contents 文管中心 發行章

DC TO AC POWER INVERTER PWRINV150W INSTRUCTION MANUAL

Installation and Operation Guide. Tundra HD 2500 Power Inverter. for the. Webasto BlueCool Truck System

Operating Instructions for Your Cobra 300 Watt POWER INVERTER M ODEL CPI 300. Nothing comes close to a Cobra

Power Inverter Vehicle Power System Converts DC Vehicle Power to 115 Volt AC Household Power

XP1200i/XP1600i/XP2000i/XP3000i POWER INVERTER OWNER S MANUAL. XP1200i. XP1600i. XP2000i. XP3000i

800 WATT POWER INVERTER

PSE-12100A PSE-12150A PSE-12250A

Battery Power Inverters

XP800i POWER INVERTER OWNER S MANUAL

DC TO AC PURE SINE POWER INVERTER PWRI18012S INSTRUCTION MANUAL

VLT SERIES. True Sine Wave AC Power Inverter. Owner s Manual. Owner s Manual D Rev.B

DC-AC MODIFIED SINE-WAVE INVERTER OWNER S MANUAL SI-750HP MODEL: Please read this manual before operating your inverter.

1RECHARGEABLE APPLIANCES

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

XPower Inverter 450. Owner s Manual

MODIFIED SINE WAVE INVERTER GP-225/400/800/1000HD

PI1500X Power Inverter User s Manual

FOR YOUR SAFETY The use of the appropriate Tundra CM Series installation kit is highly recommended

ADI-125/750 ADI-125/1500 ADI-125/2500

powerdriveinverters.com Owner s Guide Please Save for Future Reference 1500 Watt DC to AC Power Inverter

OWNER S MANUAL POWER INVERTER

SA-1000K & SA-3000K Series Pure Sine Wave Inverter User s Manual

Table of Contents. Introduction. How Your Cobra Power Inverter Works. Rechargeable Appliances 1. Quick Checkout 2-3. Operation 4

CAR series. Modified Sine Wave Inverter. P series. Pure Sine Wave Inverter. User Manual POWER INVERTER

SINE WAVE INVERTER OWNER'S MANUAL

MODIFIED SINE WAVE INVERTER GP-1750/3000/5000HD

powerdriveinverters.com Owner s Guide Please Save for Future Reference 300 Watt DC to AC Power Inverter

Operating Instructions for Your Cobra 150 Watt POWER INVERTER M ODEL CPI 150 FAULT OFF. Nothing comes close to a Cobra

powerdriveinverters.com Owner s Guide Please Save for Future Reference 750 Watt DC to AC Power Inverter

The Power of Reliability INSTRUCTION MANUAL

S600,S600R Series Pure Sine Wave Inverter User s Manual

Model: PIF-2000 Power Inverter Converts 12V DC Battery Power to AC Household Power

Toll Free DX100. Owner's Guide. Printed in China

EN120 EN180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free

XPower Inverter Owner s Guide UL

WF-5110R True Sine Wave Inverter

Owner s Manual. PowerVerterDC-to-AC Inverter

DC-AC Power Inverter SAM Manual. Please read this manual before installing your inverter

This file was converted to PDF format. If you are interested in a Microsoft PowerPoint formatted file send a request to:

XPower Inverter 3000 Plus. Owner s Guide

Table of Contents. Introduction. How Your Cobra Power Inverter Works. Rechargeable Appliances 1. Quick Checkout 2-3. Operation 4

AC Anywhere. User Manual. Power Inverter. (Class II product) Please read the installation and operations instructions before using the Power Inverters

OWNERS MANUAL JANUARY 2007 ISO

DX100. Owner's Guide Conforms to UL Std Toll Free

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) USER GUIDE

WARNING: CAUTION: Notice : XR175 Owner's Guide

SAM Series Power Inverter

FOR YOUR SAFETY The use of the appropriate Tundra CM Series installation kit is highly recommended

1000 Watt Pure Sine Wave Power Inverter, Users Manual

WF-5110R True Sine Wave Inverter

AUTOMOTIVE POWER INVERTERS INSTRUCTIONS. Item #31463, #31464, #31465

XPower Inverter 175 Plus, 400 Plus, 700 Plus. Owner s Manual

DC to AC Power Inverters

Pure Sine Wave Power Inverter SSW A SSW A SSW A SSW A SSW A

Model: PI-140 Power Inverter Converts 12V DC battery power to 120V AC household power

VertaMax Power Inverter

2500 WATT POWER INVERTER

PURE SINE WAVE DC-AC INVERTERS

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Item no Smart AC 200 USB. User s Manual

user s manual Model number

10 AMP ON BOARD BATTERY CHARGER

MEANWELL DC/AC POWER INVERTERS

Transcription:

Go Power! Manual GP-1750HD Inverter GP-2500 Inverter Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: 866-247-6527 Fax: 866-607-6527 Email: info@gpelectric.com

Table of Contents 1. INTRODUCTION... 3 2. SPECIFICATIONS... 3 3. FEATURES... 4 4. INSTALLATION... 7 5. OPERATION... 10 6. OPERATING LIMITS... 11 7. TROUBLESHOOTING... 12 8. MAINTENANCE... 13 9. WARRANTY... 13 10. RV SUPPLEMENT... 14 Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Toll Free Tel: 866-247-6527 Toll Free Fax: 866-607-6527 Email: info@gpelectric.com Rev3.3 05/05 GPModifiedSWInstallGuide.doc 2

1. Introduction The Go Power! Inverter series provides mobile power for people on the go. Run standard AC appliances wherever you travel. Silent, lightweight and simple to use, Go Power! Inverters can be used in a wide range of applications including remote homes, RVs, boats and long haul trucks. It will operate most televisions and VCR's, personal computers and small appliances including drills, sanders, grinders, mixers, blenders and microwaves. To get the most out of your power inverter, it must be installed and used properly. Please read the instructions in this manual before installing and using your inverter. 2. Specifications 2.1 GP-2500 Inverter Continuous Output Power 2500 W Surge Rating 3600 W Output Waveform Modified Sine Wave Output Voltage 115 VAC RMS +5%/-10% Output Frequency ±1% 60 Hz Input Voltage 10.5-15 VDC Efficiency 80-90% No Load Current Draw 0.8 A Protection Overload, Over Temp, Over Voltage, Under Voltage Low Battery Alarm ± 2% 10.5 V Low Battery Shut-Down ± 2% 10.0 V Operating Temperature Range 0-40 C / 32 F - 104 F Storage Temperature Range -30 C - 70 C / -22 F- 158 F Cooling Continuous fan AC Receptacle 2 Dimensions (L x W x H) mm inches 475 x 242 x 89 19 x 9.7 x 3.6 Weight kg / lbs 6 / 13.2 Warranty 1 Year Inverter Install Kit GP-DC Kit 4 2.2 GP-1750HD Inverter Continuous Output Power 1500 W Surge Rating 2100 W Output Waveform Modified Sine Wave Output Voltage 115 VAC RMS +5%/-10% Output Frequency ±1% 60 Hz Input Voltage 10.5-15 VDC Efficiency 80-90% No Load Current Draw 1.1 A Protection Overload, Over Temp, Over Voltage, Under Voltage Low Battery Alarm ± 2% 10.5 V Low Battery Shut-Down ± 2% 10.0 V Operating Temperature Range 0-40 C / 32 F - 104 F Storage Temperature Range -30 C - 70 C / -22 F - 158 F Cooling Thermostatically-controlled fan AC Receptacle 2 Dimensions (L x W x H) mm inches 482 x 240 x 83 19 x 9.4 x 3.3 Weight kg / lbs 5.5 / 12.1 Warranty 1 year Inverter Install Kit GP-DC Kit 3 3

Go Power! Modified Sine Wave Inverter 3. Features 3.1 Front view GP-2500 b. AC outlets c. Voltage graph a. Bar graph meters d. Overload indicator g. Over temp indicator e. On/Off switch f. Remote On / Off a) Bar graph meters: Display battery voltage and current. Current should be in the green zone for continuous operation. The inverter will operate for several minutes when the current is in the yellow zone. Operation with battery voltage or current in the red zone of a meter will result in protective shutdown of inverter. b) AC outlet: Outlet sockets available: North America See RV supplement if wiring to breaker panel. c) Voltage graph. d) Overload indicator: Lights up when inverter shuts down due to overloading. Turn inverter OFF, remove cause of overload and turn inverter ON to reset. e) ON/ OFF switch: Leave in the OFF position during installation. f) Remote ON/ OFF switch: Leave in the OFF position during installation. g) Over Temp. indicator: Lights up when inverter protects itself against overheating. Inverter shuts down while indicator is on. Inverter will restart automatically and indicator will turn OFF when the inverter cools. 4

3.2 Front view GP-1750HD a. Bar graph meters b. Over Temp. indicator f. Remote On/Off connector c. AC outlets d. Overload indicator e. On/Off a) Bar graph meters: Display battery voltage and current. Current should be in the green zone for continuous operation. The inverter will operate for several minutes when the current is in the yellow zone. Operation with battery voltage or current in the red zone of a meter will result in protective shutdown of inverter. b) Over Temp. indicator: Lights up when inverter protects itself against overheating. Inverter shuts down while indicator is on. Inverter will restart automatically and indicator will turn OFF when the inverter cools. c) AC outlet: Outlet sockets available: North America See RV supplement if wiring to breaker panel. d) Overload indicator: Lights up when inverter shuts down due to overloading. Turn inverter OFF, remove cause of overload and turn inverter ON to reset. e) ON/ OFF switch: Leave in the OFF position during installation. f) Optional remote plug is on bottom of inverter. 5

Go Power! Modified Sine Wave Inverter 3.3 Rear view GP-2500 b. Battery terminals a. Ventilation port Warning! Operation of the inverter without a proper ground connection may result in an electrical safety hazard. a) Ventilation port: Do not obstruct, allow at least 1 inch for air flow. b) Battery terminals: Connect to 12 V battery or other 12 V power source. Note that "+" is positive, "-" is negative. Reverse polarity connection will blow internal fuse and may damage inverter permanently. 6

Go Power! Modified Sine Wave Inverter 3.4 Rear view GP-1750HD a. Ventilation window b. Battery terminals c. Chassis ground a) Ventilation port: Do not obstruct, allow at least 1 inch for air flow. b) Battery terminals: Connect to 12 V battery or other 12 V power source. Note that "+" is positive, "-" is negative. Reverse polarity connection will blow internal fuse and may damage inverter permanently. c) Chassis ground lug: Connect to earth ground or to vehicle chassis using #8 AWG wire. *DC inverter cables not included Minimum inverter DC cable & DC inverter fuse sizes, See Section 4.3 and 4.4. 4. Installation 4.1 Where to install The power inverter should be installed in a location that meets the following requirements: Caution Do not connect this inverter and another AC source (generator or utility power) to the AC wiring or AC loads at the same time. Doing so will destroy the inverter and void the warranty, regardless whether the inverter is switched on or off. If you are using more than one AC source for the AC wiring or AC loads, it is highly recommended that you install an automatic transfer switch (GP-TS), available from Go Power! Electric Inc. a) Dry - Do not allow water to drip or splash on the inverter. b) Cool - Ambient air temperature should be between 0 C and 40 C (the cooler the better). c) Ventilated - Allow at least two inches of clearance around the inverter for air flow. Ensure the ventilation openings on the rear and bottom of the unit are not obstructed. 7

d) Safe - Do not install the inverter in the same compartment as batteries or in any compartment capable of igniting flammable liquids such as gasoline. e) Inverter should be located within 10 feet of the batteries. 4.2 Hook-up and testing To hook-up the inverter please follow these guidelines: Caution! A reverse polarity connection will permanently damage the inverter. Damage caused by reverse polarity connection is not covered by our warranty. Warning! You may observe a spark when you make this connection since current may flow to charge capacitors in the power inverter. Do not make this connection in the presence of flammable fumes, as explosion or fire may result. Caution! Connecting this inverter to AC distribution wiring or AC loads in which the neutral and ground are connected (bonded) will damage the unit and void the warranty. 1. Unpack and inspect your Go Power! Inverter, check to see that the power switch is in the OFF position. We recommend using DC Install Kits whenever installing a GP Inverter. 2. When attaching the DC inverter cables to the power input terminals on the rear panel of the power inverter. The (+) terminal is positive and (-) terminal is negative. Connect the cables into the terminals by placing the lug connector between the washers and tighten the terminal screw or nut to clamp the wires securely. Ensure connections are tight. 3. First connect the cable from the negative terminal of the inverter to the negative terminal of the battery. Make a secure connection. Caution! Loose connections result in excessive voltage drop and may cause overheated wires and melted insulation. Ensure connections are tight. 4. Before proceeding further, carefully check that the cable you have just connected is going from the negative terminal of inverter to the negative output terminal of the power source (battery). 5. Install the inverter fuse into the positive lead. Fuse should be located within 12 of battery. Ensure all connections are tight and secure. 6. Connect the cable from the positive terminal of inverter to the positive terminal of the battery. Make a secure connection. Check your polarity. Caution! This inverter cannot supply power to any AC distribution wiring or AC loads in which the neutral and ground are connected (bonded). Doing so will destroy the unit and void the warranty. If you do not understand neutral to ground bonding then please have a professional install your system for you. See Grounding for more information. 7. Set the power switch to the ON position. Check the meters and indicators on the front panel of the inverter. The voltage bar graph should indicate 11 to 14 volts depending on the voltage of the power source. If it is does not, check your battery bank and the connections to the inverter. The other indicators should be OFF. 8. Set the power inverter switch to the OFF position. The indicator lights may blink and the internal alarm may sound momentarily. This is normal. Plug the test load into the AC receptacle on the front panel of the inverter. 9. Set the power inverter switch to the ON position and turn the test load on; the inverter should supply power to the load. If you plan to measure the output voltage of the inverter, a true r.m.s. meter must be used for accurate readings. 4.3 DC Kits Go Power! DC Installation Kits include everything you will need to properly connect your 8

Go Power! Inverter to the batteries. GP-2500, GPSW-2000-12 Use GP Install Kit 4 GP-1750HD, GPSW-1500-12, GPSW-2000-24 Use GP Install Kit 3 GP-1000, GPSW-300, GPSW-600, GPSW-1000, GPSW-1500-24 - Use GP Install Kit 2 4.4 Cables DC to AC inverters require high amperage to operate properly; connect inverter DC input terminals to battery with heaviest wire available. See chart below: Max. Watts Out Approx. Amps Req'd (12 VDC) Wire Gauge 300 W 30 A #10 600 W 60 A #6 1000 W 100 A #4 1500 W 150 A #2 1750 W 175 A #2 2500 W 250 A 2 / 0 *Cable length is not recommended to exceed 10 feet in length. 4.5 Inverter fuse A class T inverter fuse should be included in all installations. GP-2500-300 amp fuse GP-1750HD 200 amp fuse GP-1000 110 amp fuse Caution! The negative DC input of the power inverter is connected to the chassis. Do not install the power inverter in a positive ground DC system. A positive ground DC system has the positive terminal of the battery connected to the chassis of the vehicle or to the grounding point. Warning! Do not operate the power inverter without connecting it to ground. Electrical shock hazard may result. 4.6 Grounding The power inverter has a lug on the rear panel: "Chassis Ground." This is to connect the chassis of the power inverter to the ground. The ground terminals in the AC outlets on the front panel of the inverter are also connected to the ground lug. To ground the GP- 2500, connect grounding wire to one of the mounting screws and sand the connection before attaching the wire. The chassis ground lug must be connected to a grounding point, which will vary depending on where the power inverter is installed. In a vehicle, connect the chassis ground to the chassis of the vehicle. In a boat, connect to the boat's grounding systems. In a fixed location, connect the chassis ground lug to earth. The neutral (common) conductor of the power inverter AC output circuit is not bonded to the chassis ground. Therefore, when the chassis is connected to ground, the neutral conductor will not be grounded. At no point should the chassis ground and the neutral conductor of the inverter be bonded. Bonding the chassis ground and the neutral conductor of the inverter or connecting the inverter to household or recreational AC distribution wiring will damage the unit and void the warranty. 9

*Installation using two 12 volt batteries _ GP Inverter Fuse + 12 V 12 V * Installation using two 12 volt batteries. Fuse _ + 6 V _ * Installation using two 6 V batteries. GP Inverter + 6 V 5. Operation To operate the power inverter, turn it on using the ON/OFF switch on the front panel. The power inverter is now ready to deliver AC power to your loads. If you are operating several loads from the power inverter, turn them on separately after the inverter has been turned ON. This will ensure that the power inverter does not have to deliver the starting currents for all the loads at once. 5.1 Controls and indicators The ON/OFF switch turns the control circuit in the power inverter ON and OFF. It does not disconnect power from the power inverter. When the switch is in the OFF position, the power inverter draws no current from the battery. When the switch is in the ON position but with no load, the power idle current is approximately 1 A (see product specifications for exact current draw). 5.2 Optional On / Off remote The optional remote switch can be used to turn the inverter on and off from a location up to 25 feet away. The inverter should be OFF when plugging remote in. Once the remote is installed the inverter ON/OFF switch must be in the ON position. 10

5.3 Battery voltage indicator The battery voltage bar graph indicates the voltage at the input terminals of the power inverter. At low input current, this voltage is very close to the battery voltage. At high input current, this voltage will be lower than the battery voltage. Ideally, the voltage should remain in the green areas of the bar graph. If the voltage goes into the red area at the top or bottom of the graph, the inverter may shut-down. 5.4 Battery current indicator The battery current bar graph indicates the current drawn from the battery by the power inverter. It will not indicate current by other loads also connected to the battery. For long-term operation, the current should be in the green area of the bar graph. Short-term operation is possible with current in the yellow area. If the current rises to the red area, the inverter will shut itself down and the overload indicator will light. 5.5 Overtemp indicator The overtemp indicator indicates that the power inverter has shut itself down because the inverter has become overheated. The power inverter may overheat because it has been operated at power levels above its rating, or because it has been installed in a location which does not allow it to dissipate heat properly. The power inverter will restart automatically once it has cooled off. 5.6 Overload indicator The overload indicator indicates that the power inverter has shut itself down because its output circuit has been short circuited or drastically overloaded. Switch the ON/OFF switch to OFF, correct the fault condition, and then switch the ON/OFF switch back to ON. 6. Operating limits 6.1 Power output The inverter will operate most AC loads within its power rating. When determining whether a microwave oven can be operated by the GP-1750 Inverter, remember that the power commonly advertised for microwave ovens is the cooking power (the power delivered to the food), not the power actually consumed by the microwave oven. The microwave oven will consume 40% to 100% more than its advertised cooking power. Check the rating sticker on the back of the oven to determine its actual power draw. The GP-1750HD inverter will operate small microwave ovens (0.2 to 0.3 cubic foot capacity) that draw about 1700 watts. It will provide 10 to 45 minutes of cooking time. Some induction motors used in refrigerators, freezers, pumps and other motor operated equipment require very high surge currents to start. The power inverter may not be able to start some of these motors, even though their rated current draw is within the power inverter. If the motor refuses to start, observe the battery voltage indicator while trying to start the motor. If the battery voltage indicator drops below 11 volts while the inverter is attempting to start the motor, this may be why the motor will not start. Make sure that the battery connections are good and that the battery is fully charged. If the connections are good and the battery is charged, but the voltage still drops below 11 volts, you may need to use a larger battery. 11

6.2 Input voltage The power inverter will operate from input voltage ranging 10 V 15 V. If the voltage drops below 10.7 V, an audible low battery warning will sound and the voltage indicator will be in the lower red zone. The power inverter will shut down if the input voltage drops below 10 V. This protects your battery from being over discharged. The power inverter will also shut down if the input voltage exceeds 15 V. This protects the inverter against excessive input voltage. The voltage indicator will be in the upper red zone. Although the power inverter incorporates protection against overvoltage, it may still be damaged if the input voltage is allowed to exceed 20 V. 7. Troubleshooting Note: There are audible low voltage / over load alarms on all inverters. 7.1 Common problems a) Buzz in audio systems Some inexpensive stereo systems will emit a buzzing noise from their loudspeakers when operated from the power inverter. This is due to the power supply in the device does not adequately filter the modified sine wave produced by the power inverter. The only solution is to use a sound system that incorporates a higher quality power supply. b) Television interference Operation of the power inverter can interfere with television reception on some channels. If this situation occurs, the following steps may help to alleviate the problem. Make sure that the chassis ground lug on the back of the power inverter is solidly connected to the ground system of your vehicle, boat or home. With the exception of the GP-2500 which would connect to one of the mounting screws. Do not operate high power loads with the power inverter while watching television. Make sure that the antenna feeding your television provides an adequate ("snow free") signal and that you are using good quality cable between the antenna and the television. Move the television as far away from the power inverter as possible. Keep the cables between the battery and the power inverter as short as possible and twist them together with about 2 to 3 twists per foot. This minimizes radiated interference from the cables. 7.2 Troubleshooting guide Problem and Symptoms Possible Cause Solution Low AC output voltage 95-105 VAC. Using standard voltmeter. Use true RMS averaging meter. Low output voltage and current indicator in red zone. Overload. Turn off. Reduce load, turn on. No output voltage and voltage indicator in lower red zone. Low DC input voltage. Recharge battery, check connections and cable. 12

No output voltage, no voltage indication. No output voltage, voltage indicator in upper red zone. Low battery alarm on all the time, voltage indicator below 11 V No output voltage, Over Temp indicator on, load in excess of: 2500 W: 210 A 1750 W: 145 A No output voltage, Over Temp indicator On, load less than: 2500 W: 210 A 1750 W: 145 A No output voltage, Over Load indicator on Inverter switched off. No power to inverter. Internal fuse open. Reverse DC polarity. High input voltage. Poor DC wiring, poor battery condition. Thermal shutdown. Thermal shutdown. Short circuit or wiring error. Very high power load Turn inverter on. Check wiring to inverter. Have qualified service technician check and replace. Have qualified service technician check and replace fuse, OBSERVE CORRECT POLARITY. Make sure that inverter is connected to 12 V battery. Check regulation of charging system. Use proper cable and make solid connections. Use new battery. Allow inverter to cool off. Reduce load if continuous operation required. Improve ventilation; make sure ventilation openings in inverter are not obstructed. Reduce ambient temperature. Check AC wiring for short circuit or improper polarity (hot and neutral reversed). Remove load. 8. Maintenance Very little maintenance is required to keep your inverter operating properly. You should clean the exterior of the unit periodically with a dry cloth to prevent accumulation of dust and dirt. At the same time, tighten the screws on the DC input terminals. 9. Warranty We warrant this product against defects in materials and workmanship for a period of 12 months from the date of purchase and will repair or replace any defective Go Power! Inverter when directly returned, postage prepaid, to the manufacturer. This warranty will be considered void if the unit has suffered any obvious physical damage or alteration either internally or externally, and does not cover damage arising from improper use such as plugging the unit into an unsuitable power sources, attempting to operate products with excessive power consumption requirements, reverse polarity, or use in unsuitable climates. This is the only warranty and the company makes no other warranties, express or implied, including warranties of merchantability and fitness for a particular purpose. Repair or replacement are your sole remedies and shall not be liable for damages, whether direct, incidental, special or consequential, even though caused by negligence or other fault. 13

10. RV Supplement 10.1 Installing the GP-2500, GP-1750HD, and without an automatic transfer switch Plug main power cord into inverter (a 15 amp adapter may be required). Battery inter-connects should be a minimum of 4 gauge. Ensure converter is turned Off when plugging into inverter. To avoid hidden loads turn inverter off when power is not required. On/Off Remote (Optional) Go Power! Fuse RV Power Cord GP Inverter 12 V Batteries *DC connections use appropriate GP DC Install Kit. 10.2 Installing the GP-2500, GP-1750HD, and with an automatic transfer switch Battery inter-connects should be a minimum of 4 gauge. Ensure converter is turned Off when inverter is operating. To avoid hidden loads turn inverter off when power is not required. Shore Power Cord Remote On/Off (Optional) Go Power! Fuse Converter Go Power! Transfer Switch AC to Plug GP Inverter *DC connections use appropriate GP DC Install Kit. 12V Batteries 14