Unitized Quick Install Switches for Substation Applications

Similar documents
Unitized Quick Install Switches for Transmission Applications

CLEAVELAND / PRICE INC. Type RL-C Side Break Switch kv A. Bulletin DB-104E12

Copper Double Break Switch

Operators/Accessories. Type V2-CA Aluminum. Vertical Break Switch. Ordering Information Furnish: Available Accessories. Standard Operator Features

Aluminum Vertical Break Switch kv A.

Copper Vertical Break Switch kv A.

Aluminum Vertical Break Switch 345 kv, 1300 kv BIL 2000 A A.

Switchgear Skid, C1192

INSTRUCTIONS For Field Assembly and Installation

Transmission Switching

Indoor or Outdoor 2400 to 14,400 Volts 600 to 14,400 Kvac, 3 Phase, 60 Hz

Transmission Switching

MODULAR BARGE SYSTEM

Outdoor vacuum breaker for railway applications - FSK II

INSTRUCTIONS. S&c Circuit-Switchers - Mark v Grounding Switches - 70,000 Amperes Momentary Outdoor Transmission I INTRODUCTION INSTRUCTION SHEET 7 1 1

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

The Standard Mounting Arrangements for S&C Omni-Rupter Switches

Packaging Processing. Bid on Equipment TANKS PROCESS SYSTEMS & EQUIPMENT

24 k B788 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

TYPE EE and EEB CENTER- SIDE-BREAK SWITCH TYPE VEE and CBV CENTER BREAK V SWITCH 1200, 1600, 2000 & 3000 Amperes 7.

Installation And Operation

POWERCON CORPORATION

S&C TripSaver II. Cutout-Mounted Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv

Publication No.: PSG

S&C Circuit-Switchers Mark VI Installed on S&C Mounting Pedestals 84- through 102-inch Phase Spacing Outdoor Transmission (69 kv through 138 kv)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

CENTER BREAK GROUP OPERATED AIR BREAK SWITCHES RATED 15.5kV THROUGH 170kV EFFECTIVE DATE: 10/25/16 REV B

University of Houston Master Construction Specifications Insert Project Name

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

Power & High Voltage Joslyn Hi-Voltage Overhead Reclosers & Switches H-220. Series HVI Hi-Velocity Interrupter Attachment

S&C Alduti-Rupter Switches. Outdoor Distribution, 14.4 kv through 69 kv

Service Bulletin 161 SUBJECT: Upgrade to current production level

Horizontal Circuit Switchers

S&C Circuit-Switcher Mark VI Outdoor Transmission (69 kv through 138 kv)

IRON HORSE SEATING Series OWNER S MANUAL

Gas-insulated medium-voltage switchgear. For the mining industry. Answers for energy.

WORKING SAFELY NEXT TO WEST MIDLANDS METRO

ON LOAD GEARS OPERATIONAL AND MAINTENANCE MANUAL VACUUM CIRCUIT BREAKER TYPE VS36

TYPE V CENTER BREAK SWITCH

Modular Standardized Electrical and Control Solutions for Fast Track Projects

PUB NLH 174 Island Interconnected System Supply Issues and Power Outages Page 1 of 4

Medium voltage NEX switchgear Withdrawable circuit breaker. Quite simply efficient

IB-FAS3 Mar Type FAS THRU 115Kv Amp 61 KA Momentary. Vertical-Break, Gang-Operated Outdoor Air Disconnect Switch.

ON LOAD GEARS OPERATIONAL AND MAINTENANCE MANUAL VACUUM CIRCUIT BREAKER TYPE VS12

ABB Automation & Power World: April 18-21, 2011 EPO How 38kV R-MAG Can Be Used in Wind Farm Applications. ABB Inc. April 20, 2011 Slide 1

Padmount Solid Dielectric Switchgear Catalog

TRANSFORMER SERVICE. ABB Ability inspection for transformers TXplore Oil-filled transformer internal inspection service

Instructions for Installation and Operation

TECMAN PEDESTAL ROCKBREAKER BOOMS

S&C Mini-Rupter Switches Application The Standard Mounting Arrangement Scheme for S&C Mini-Rupter Switches Typical ED, reduced from full 11 size.

B kv T&D GAS INSULATED SWITCHGEAR

PASS M00. Multifunctional modules for high voltage substations kv; A;... 31,5 ka

Substation Committee K2 TF1 of the GIS Subcommittee GIS/GIL/SF 6 -Tutorials

SION vacuum circuit-breaker.

Gas-insulated medium-voltage switchgear. For the metal industry. Answers for energy.

Dead Tank Outdoor Vacuum Circuit Breaker, Type VOX

When power interruptions happen.

Detail Bill of Material Page 1 of 1 Project Name: Amphi School - MVS Replacement Negotiation No: TU700213X7K2 General Order

Solid Dielectric, Single Phase Recloser

D'Shannon Products, Ltd County Road 134 Buffalo, MN Supplemental Type Certificate SA2200SW. Installation Instructions

Medium Voltage Products Table Of Contents

The 42 K.1 fast-erecting crane. Highly adaptable

S&C Series 2000 Circuit Switchers Outdoor Transmission (69 kv through 230 kv)

IB PowlVac ITE-HK Remote Racking Device

B-03 ELECTRICIAN TRAINING SKILL DEVELOPMENT GUIDE

JCB ATTACHMENTS FOR MINI AND MIDI EXCAVATORS A class-leading range of attachments suitable for mini and midi excavators.

Installation. S&C Omni-Rupter Switches Outdoor Distribution 14.4 kv and 25 kv

Extra-High-Voltage SF 6 Gas-Insulated Switchgear

Horizontal Circuit Switchers

High voltage products PASS M0S 252 kv Innovative solution for transmission substation up to 252 kv

GTX UNIT SUBSTATION Installation, Maintenance & Operation Manual

FA Off-Load Switches. Up to 8000 A and 3000 V AC/DC Expertly engineered for reliable performance

SPECIFICATION BULLETIN

Medium Voltage Drives. ABB Value Provider Program Partnership for growth and profit

Extensible Unit - VCE2a

Power IT MV Live Tank Vacuum Circuit Breaker Model VBF

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

SM-1700 Secondary Shunt Trip Coil Assembly. Powered by Safety

Medium Voltage Products Table Of Contents

B kv Gas-insulated Substations

ECO 250 CUTTER SUCTION DREDGER

Overview Gas Insulated Switchgear Modular and flexible, kV. ABB Group April 17, 2009 Slide 1

PJM Generation Interconnection Request Queue #A55 Lakewood 230kV Facilities Study Report

Hydro Power Synchronous Generators. Power range MW

Instructions for Installation and Operation

Overview Gas Insulated Switchgear Modular and flexible, kV. ABB Group May 15, 2013 Slide 1

EE064D: Circuit Breakers & Switchgears: Design, Testing, Commissioning, Maintenance, Repair & Troubleshooting

Albany RR1000. Mechanical Installation Manual. PN: 6410T0029 Version - Rev: 04/23/2014. ASSA ABLOY Entrance Systems

M Damper Mount Linkage Kit Installation. Item Description Quantity Item Description Quantity Nuts 2

Asphalt Machines. Lots of different shapes and sizes

Structure of Wind Supply Chain Onshore to Offshore. Ed Weston Director, GLWN Copyright 2012 GLWN A WIRE-Net Initiative

COMMERCIAL QUICK REFERENCE

FOR PRICES ON DSII and DSLII BREAKERS, REFER TO PRICE LIST PL.22B.01.P.E

ibusway for Data Center

Power IT MV Live Tank Vacuum Circuit Breaker. Model OVB-SDB

High-speed folding doors. F Series

Instructions for Installation

Xtreme Air Command. Step 1 Prepare the components. Step 2 Select a mounting location. Parts list

Transcription:

Bulletin DB-680A15 Unitized Quick Install Switches for Substation Applications CLEAVELAND / PRICE INC. 14000 Rt. 993, Trafford, PA 15085 (724) 864-4177 FAX (724) 864-9040 Email: sales@cleavelandprice.com

Cleaveland/Price Quick Install Substation Switches Cleaveland/Price Quick Install switches are unitized switches that ship from the factory fully assembled and adjusted on a mounting frame or on a customer s mounting structure. These unitized switches are available for any group operated switch design from 15 kv through 230 kv for installation in a substation. Unitized switches are also available for transmission line applications (Reference bulletin DB-605A12). Quick install switches are engineered to customer specifications. The customer stipulates switch type, rating, structure type (number of support legs), mounting position, phase spacing, and distance from the ground to bus centerline (when applicable); Cleaveland/ Price takes care of the rest. Drawings for approval are submitted prior to fabrication. Cleaveland/Price Cost switch assemblers take the effective guesswork out of switch adjustment. Each pole unit is expertly adjusted on the factory floor and the three phases are further adjusted Quick Install Substation Switches Easy to install Switch adjustment is not necessary during or after installation Customized to customer specifications Ideal for situations that require a fast switch installation Reduces the amount of crane time necessary at site to work in perfect unison. The switch arrives at site ready to install. Once the design is tried and proven, it can become a standard that takes all of the headaches and sweat out of future installations. Options in supplying unitized switches are: The entire mounting structure can be supplied by Cleaveland/Price or be supplied by the customer and drop shipped to Cleaveland/ Price. The switch would be mounted to a platform and the manual or motor operator and vertical operating pipe would be installed on the support pedestal or legs. Cleaveland/Price can supply the switch on a platform for installation on customer s pedestal. With Cleaveland/Price Quick Install switches, you can take advantage of our expertise while reducing your installed asset costs. Utilities that use contractors to install switches find that Quick Install switches solve all of their skill level problems. How Well Does It Work? A major northeast utility had a critical location substation at which they needed to replace twenty-one 230 kv vertical break switches in a short outage window. All of the switches had ground blades on one or both ends of the switch. The utility planned three outages of three days each to accomplish this task and they turned to Cleaveland/Price to help make it happen. Cleaveland/Price had introduced the unitized switch concept to the utility on an earlier project. Over the course of three weeks, Cleaveland/ Price delivered seven fully assembled and adjusted Quick Install switches per week. The utility worked efficiently to remove the existing switches and install the new unitized switches. During each outage, seven switches were installed in two days. No adjustments were required on any of the twenty-one switches. By using Cleaveland/Price Quick Install switches, the utility was able to meet their aggressive schedule and avoid significant system costs that would have been incurred by longer outages.

Switch Installation - It s this easy! 1 2 The switch pole units are assembled and mounted on a structural platform. Interphase operating linkage is installed and the main switch and ground switches are then adjusted. The unitized switches ship from the Cleaveland/Price factory fully assembled and adjusted on the structural platform. When at the jobsite, 3 4 the vertical structural support legs with operating mechanism attached are removed from the truck and fastened to the foundation anchor bolts. The unitized switch is removed from the truck and positioned over the vertical supports. 5 6 Coupler The switch platform is bolted to the two vertical support legs and the operating mechanism vertical pipe is bolted to the outboard bearing assembly via a coupler. Eleven bolts after the structure legs are anchored, the motor operated switch is completely installed and operating electrically! Installation time for this 230 kv switch with hinge and jaw end ground blades was less than one hour. No field adjustment was needed.

We were from truck to pole and gone in 45 minutes! 6.00 36.00 36.00 7.00 17.00 17.00 7.00 DETAIL A 16.38 46.00 10.25 A 6.00 11.37 36.00 42.00 5.00 15 kv, 2000 A. V2-CA unitized vertical break switch with direct drive to the center phase rotating insulator.

69 kv Double Break Quick Install Switch In this application, the customer was isolating a breaker and needed to disconnect both sides of the breaker. Cleaveland/Price supplied two vertically oriented double break switches mounted back-to-back on a frame. The frame was engineered to attach to two tall vertical structure members supplied by the customer. The two vertical members were shipped to Cleaveland/Price for pre-delivery mounting of the operating linkage. The switch shipped with all the operating linkage in place and only needed the joining of two couplers to be operable. The switches and structure were built in the factory to install the operating mechanism linkage and adjust the switch. After the switch was adjusted, it was removed from the vertical supports and loaded on a flatbed, ready to be reassembled at the jobsite. At site, the vertical supports were erected and the switch mounting frame was attached to the supports. Coupling the vertical operating pipes to the outboard bearing assemblies completed the installation.

THIS CHANNEL ASSEMBLY MUST BE REMOVED PRIOR TO ENERGIZATION THIS CHANNEL ASSEMBLY MUST BE REMOVED PRIOR TO ENERGIZATION ROTATES APPROX. 180ºCCW TO OPEN 5-6 5-6 ALTERNATE DRIVE LOCATION ROTATES APPROX. 180ºCCW TO OPEN 10-0 ALTERNATE DRIVE 9.75 LEVER POSITION 11-0 10-0 7.58R 2-0 2-0 ALTERNATE DRIVE LOCATION 1-0 8-8 115 kv, 1200 A. V2-CA unitized vertical break switch with vacuum interrupters mounted on the customer s vertical supports. Unitized switch assembled at the factory. The unitized switch is attached to the supports. The switch is lifted into place. Installation is complete in less than one hour. www.cleavelandprice.com