HPP18V MULTI FLEX Hydraulic Powerpack

Similar documents
HPP09E Hydraulic Powerpack

HPP13D Hydraulic Powerpack

Rhino HPP13 Flex Hydraulic Powerpack

Rhino HPP18V FLEX Hydraulic Powerpack

HH10/HH10RV Hydraulic Breaker

HPP06. Hydraulic Powerpack. HYCON A/S Juelstrupparken 11 DK-9530 Støvring Denmark

HWP2/HWP3/HWP4 Hydraulic Submersible Pumps

Hydraulic Breakers HH35. Prior to Operation. From Serial No Revised We thank you for choosing a HYCON breaker.

HCS14/16/18 Hydraulic Cut-off Saw. Prior to Operation. We thank you for choosing a HYCON cut-off saw.

HPD Hydraulic Post Driver

Operating Manual TYROLIT ( ) A Company within the SWAROVSKI Group

HWP2/HWP3/HWP4 Hydraulic Submersible Pumps

Operating Manual. Type: Hydraulic Submersible Pump 3 inch WARNING! PN: H % electric shock proof. explosion proof.

Rhino HBR 60 Hydraulic Breaker

- the choice of. professionals...

- the choice of. professionals...

LH 25 S/E HYDRAULIC BREAKER OPERATING MANUAL Serial Nos Issued 22/10-03 Revised 11/06-04

LP 9-20 E PAC. Crowder Supply Co., Inc Roslyn St., Commerce City, CO Toll Free:

Ex m Solenoid Operator Type 0519

Safety and operating instructions

PETROL CHAINSAW - THPCS18

Safety and operating instructions

muck-truck It doesn t cost the earth to move it! OWNERS & OPERATIONS INSTRUCTION MANUAL

OPERATION AND MAINTENANCE MANUAL SERIES HIGH GRASS MOWER FT

POWER PACK W/OIL COOLER P/N 32800

Chain-saws (combustion engine powered)

LP DEL PAC. ATLAS COPCO CONSTRUCTION TOOLS AB NACKA SWEDEN No

PREFACE. Thank you for your purchase of the Böhler-AG Petrol Generator.

Safety and operating instructions

F B F B USER MANUAL. spac100. Dok: A-GB 0820

Ride-on lawnmowers (combustion engine powered)

FB 160 FB 175 FB 235 FB 255 FB 265 USER MANUAL IN ORIGINAL

Tillers Motor hoes (combustion engine powered)

PORTABLE CONCRETE VIBRATOR

Safety and operating instructions

Safety and operating instructions

PETROL CHAINSAW - THPCS18

Instruction Manual. Pressure Manhole Covers - HLSD IM70871-EN

Safety and operating instructions

Spa USE AND MAINTENANCE CULTIVATOR MODEL BL300 / BL350

Beton Trowel nv INSTRUCTION MANUEL SLAB SAW BTCS500 - GEBABEBB BBRUBEBB BNP FORTIS: ING: BE BE

30-Aug-11. VCA job number: CSM Date: 30 August Dear Sirs,

LWP 2, LTP 3. Safety and operating instructions. Submersible pumps Construction Tools EOOD No f Original instructions

Hedge trimmers (combustion engine powered)

Safety and operating instructions

Ropox Shower & Changing Bed

11-Feb-14. VCA job number: CSP Date: 11 February Dear Sirs,

SKF Electro-pneumatic Barrel Pump EPB-Pump-ECO (Original operating and maintenance instructions according to EU Directive 2006/42/EC)

Single Phase Floor Grinder

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

PETROL GENERATOR SPG2200, SPG3000, SPG6500 OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.

Instruction Manual. Maple 8/25 Pump. Model

KMR 1200 B (06/99)

Instruction Manual. Unique Single Seat Valve - Manually Operated ESE00523-EN Original manual TD TD

PALLET TRUCK PAINTED OPERATING INSTRUCTIONS MAINTENANCE MANUAL PARTS CATALOGUE DECLARATIONS OF CONFORMITY

DYNAPAC CONCRETE EQUIPMENT RAMIRENT. BG70 Power Floats INSTRUCTIONS & SPARE PARTS CATALOGUE BG70 - IS ENG

REEL ROTATOR SELFRRM/SELFSRRM, SELFRRE/SELFSRRE

EU DECLARATION CONFORMANCE

Instruction Manual. Magnetic Mixer MM UltraPure ESE01696-EN Original manual TD

GARBAGE CANS 120L / 240L

Petrol Driven Water Pump. Model No. CD1-1 Part No OPERATING & MAINTENANCE INSTRUCTIONS

HIGH LIFTER MANUAL, LAKERET

PETROL GENERATOR PGH2200, PGH3000, PGH6500 OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.

PNEUMATIC PUMP Series

IMPORTANT: Read this manual fully before assembly and use and observe all safety rules and operating instructions

Operating Instructions LEO 23 GT

Instruction Manual. Unique Single Seat Valve - Manually Operated ESE00523-EN Original manual TD TD

manual addendum ROBUS Ex

c-go 24V/6A 24V/8A 24V/12A

LDG6000SA DIESEL GENERATOR OWNERS MANUAL

AK / AV 4 & 5 SERIES Metallic Vertical Centrifugal Pumps Installation and Maintenance Instructions

Instruction Manual. * We reserve the right to amend specification without prior notice.

F 167/94 07/ GM-

EU30is POWEREQUIPMENT.HONDA.COM.AU

PANTHER MAXI AC / MINI

BA-4 AIR-JECT AERATOR OPERATOR S MANUAL & PARTS BREAKDOWN

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

PF-4000, PF-4010, PF-4210 MULTI-PURPOSE ENGINE

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

Declaration of Conformity as per Directive 97/23/EC

08-Dec-10. VCA job number: CSL Date: 08 December Dear Sirs,

INSTALLATION, OPERATION & MAINTENANCE MANUAL MODEL BC.

THE UNITED KINGDOM TYPE APPROVAL AUTHORITY

AGREEMENT. done at Vienna on 13 November Addendum 1: Rule No. 1. Revision 1

Differential Proportional Flow Control Valve DPCMEE 16 & 20

FB 300 FB 450 FB 700 USER MANUAL

GPA520 PETROL AUGER OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.

MV Series Motors Operation & Parts Manual

NEPTUNE 8. Supplement to Service Manual NEPTUNE 5 / 7

Technical Data Technical Data. 3.1 Views TE Fig. 3 Digging envelope TE2-03

User manual. B950I, B1000i, B2000i, B3000i

Operating Instructions Gasoline Hedge Trimmer. After Sales Support. TEL: WEB: BG-PH2250 N16188

1100W PORTABLE GENERATOR

Shutdown valves II 2 G. Type 1073

CE DECLARATION OF CONFORMITY

Vacuum Pumps PM80T MORO USA, INC. Use and maintenance manual. ST. LOUIS, MO OFFICE PO Box 632 UNION, MO (866) Fax: (636)

ENGINE DRIVEN 3 FULL TRASH PUMP

Instruction Manual. SMP-BCA Aseptic Mixproof Valve with PTFE Diaphragm IM70811-EN

Instruction Manual. LKAP Air-Operated Valve ESE01993-EN Original manual

BD 1202 BD 1402 BD 2002 BD 2402 BD 3102

Transcription:

HPP18V MULTI FLEX Hydraulic Powerpack From serial number 2124 Revised 12.05.09 Prior to Operation We thank you for choosing a HYCON powerpack. Please note that the powerpack is delivered without hydraulic oil, and therefore it must be filled up with hydraulic oil prior to operation. To ensure smooth operation and long-lasting performance of your new powerpack, we recommend that you study this operating manual carefully and pay special attention to the Safety and Service Precautions HYCON A/S Juelstrupparken 11 DK-9530 Støvring Denmark Tel: +45 9647 5200 Fax: +45 9647 5201 Mail hycon@hycon.dk www.hycon.dk We hope you will be satisfied with your new HYCON powerpack. Best regards HYCON A/S

Contents Page Safety precautions... 2 Filling up hydraulic oil... 2 Technical data... 3 Starting instructions... 4 Setting of flow... 4 Service, maintenance and hydraulic settings... 4 Oil types... 5 EC-Declaration of Conformity... 6 Warranty conditions... 7 Spare parts list... 8 1

Safety Precautions 1. Always use protective earplugs. The powerpack complies with the EU noise limit, but by daily long-lasting operation there is a risk of hearing defects. 2. Always connect hoses before starting. 3. Never add fuel and oil when the engine is running. 4. In case of non-operation or performance of service, always turn off the engine. 5. Never start the engine without side covers. 6. Operation of the powerpack without tool connected and with lever at ON may cause overheating of the system and damage to the powerpack. 7. When lifting the powerpack from a vehicle, we recommend the use of a crane. 8. The pressure relief valves are set at 160 bar from our plant. Never set them higher. 9. Always use filters with by-pass. The use of filters without by-pass may blow the hydraulic hoses and the filter cover. Filling Up Hydraulic Oil To fill up with hydraulic oil, loosen the filter cover on top of the powerpack. Remove the filter element (see photo), and fill up with oil. When oil is showing at the bottom of the filter unit, there is enough oil on the powerpack. Insert the filter element again, mount the cover and the powerpack is ready for use. Please note: When connecting new extension hoses, it is necessary to fill up with extra 2 litres of oil. Therefore always top up the powerpack when connecting new extension hoses. 2

Technical Data Hydraulics The HYCON HPP18V MULTI FLEX open centre powerpack is designed in accordance with the EHTMA categories C, D and E, which prescribe a performance of 20, 30 and 40 l.p.m. respectively at 138 bar. The HYCON powerpack is fully compatible with and sufficient for the common European tools. The powerpack is mounted with a double pump (two independent hydraulic circuits), and it has three connections for each circuit separately or both circuits simultaneously. This way the powerpack can operate two tools simultaneously. For a more detailed description, please refer to the section about Setting of Flow The powerpack is mounted with pressure relief valves to avoid a too high pressure. Furthermore, the very efficient air cooling protects the powerpack against overheating. The powerpack has no POR system, and the engine r.p.m. (oil flow) is adjusted manually by means of the throttle. Oil flow connection A Oil flow connections B and C Working pressure nominal Pressure relief valves Pump Oil temperature Capacity hydraulic oil tank Capacity petrol tank Hydraulic system complete Filter system (filter element) Engine 20 l.p.m. at 1800 r.p.m. 30 l.p.m. at 2700 r.p.m. 40 l.p.m. at 3600 r.p.m. 10 l.p.m. at 1800 r.p.m. 15 l.p.m. at 2700 r.p.m. 20 l.p.m. at 3600 r.p.m. 120 bar Set at 160 bar Double gear pump Max. 70 C Min. 8 litres/max. 11 litres 8.5 litres 12 litres 25 Micron with by-pass Vanguard 2-cylinder 18 HP (gross power) 4-stroke petrol Normal or unleaded petrol Engine oil 1.1 litres Guaranteed sound power level L WA 101 db Sound pressure level 1 m L PA 89 db Dimensions (LxWxH) Weight w/o hydraulic oil 850x625x695 mm 112 kg 3

Starting Instructions Please observe the starting instructions on the front of the powerpack. Start: Stop: Check engine oil level Check hydraulic oil level at sight glass Connect hoses and tool Switch fuel tap to ON Activate choke Turn ignition key Activate electric start or pull recoil starter Set the flow see below Move all levers to OFF Turn off the ignition switch Turn the fuel tap to OFF Setting of Flow The powerpack has three connections, allowing for connection of two tools simultaneously. The connections are marked A, B and C, respectively. The oil flow can be adjusted by regulating the engine r.p.m. by means of the throttle. Connection A can be set to 20-40 l.p.m. Connections B and C can be set to 10-20 l.p.m. Connection A cannot be used simultaneously with connections B and C. Each connection is equipped with an ON-OFF lever. Connections not in use must be set at OFF, and connections in use must be set at ON. Connections B and C can only be used when connection A is OFF. Never turn the lever to ON if no tool is connected. 4

Service, Maintenance and Hydraulic Settings Service/Maintenance Daily Weekly Yearly Engine oil Check 1 x replacement Hydraulic oil Check 1 x replacement Hydraulic oil filter *) 1 x replacement check hoses (tighten up if needed) Air filter 1 x replacement Fuel filter 1 x replacement *) use only filters with by-pass Hydraulic Settings Check the working pressure by means of test equipment. The test equipment must comprise a pressure gauge, a flow meter and a valve for adjustment of pressure. The pressure relief valves are placed on the valve block. There are two pressure relief valves (one for each hydraulic circuit), and they must be adjusted individually. The pressure relief valves are marked with B and C respectively. 1. Connect the test equipment to connection B, start the powerpack and move the B lever to ON and the A and C levers to OFF. Then close the valve on the test equipment and adjust the pressure relief valve B according to the technical data. Adjust the pressure relief valve by loosening the lock nut and turning the adjustment screw in or out. In increases the pressure, and out decreases the pressure. Retighten the lock nut after adjustment. Connect the test equipment to connection C, start the powerpack and move lever C to ON and levers A and B to OFF. Then close the valve on the test equipment and adjust the pressure relief valve C according to the technical data. 2. Having adjusted the pressure relief valves correctly, set the working pressure to 100 bar by means of the valve on the test equipment. At 100 bar the oil flow should correspond to the flow rate which the lever is set at (see Setting of Flow). If correct pressure/oil flow cannot be achieved by following the above instructions, the powerpack must be re-adjusted. If the pressure/oil flow is then still incorrect, the pump is defect and must be replaced. 5

Oil Types The HYCON powerpack uses standard hydraulic oil, i.e. all types of mineral oil and biodegradable oil, which comply with the following values: Recommended viscosity 20-40 cst Permitted viscosity 15-1000 cst Viscosity index Min. 100 Temperature area -20 to +70 C 6

EC-Declaration of Conformity HYCON A/S Juelstrupparken 11 DK-9530 Støvring Denmark Tel: +45 9647 5200 Fax: +45 9647 5201 Mail hycon@hycon.dk www.hycon.dk We hereby declare that HPP18V MULTI FLEX hydraulic powerpack - from serial No. 2124 (with 13.4 kw petrol engine) is manufactured in conformity with the EC Directives 2006/42/EC and 2000/14/EC. Notified Body 1585: AkustikNet A/S Frederikssundsvej 179 B DK-2700 Brønshøj Denmark Guaranteed sound power level: 101 db HYCON A/S Juelstrupparken 11 DK-9530 Støvring Danmark Henrik Steen General Manager 2 January 2006 7

Warranty Conditions We grant 12 months warranty from the first date of operation however, not more than 18 months from the date of delivery. The warranty applies to faults that can be related to construction and production errors. Faults caused by incorrect operation, incorrect handling, lack of maintenance or the like will not be accepted as warranty. The warranty covers the parts necessary for repair and the suggested average time needed for repair. For further warranty details, please contact your local dealer. 8