Data Sheet 40.00 Page /8 JUMO MIDAS S05 Pressure transmitter Type 4000 Brief description The JUMO MIDAS S05 pressure transmitter is available with both relative pressure and absolute pressure measurement ranges. The high-quality stainless steel welded measuring system with no seals ensures the instrument can be used in almost all media, even under harsh conditions. The design offers optimum safety against process medium escaping. The instrument features a silicon sensor that is able to handle extreme overload, even in the lowest measurement ranges, and is capable of millions of pressure cycles. Many applications may be found in cooling and air conditioning systems, compressors, mechanical engineering, commercial vehicles, and industrial pneumatic uses. Type 4000/... Key features Welded measuring system without seals Parts in contact with medium made of stainless steel Resistant to coolants Extremely overload-resistant For measuring relative and absolute pressure Available with terminal box to DIN 4650
Data Sheet 40.00 Page /8 Technical data General Reference conditions Per DIN 6 086 and DIN EN 60770 Sensor Material Pressure transfer medium Permissible load change Location Mounting location Calibration location Silicon sensor with stainless steel separating diaphragm Synthetic oil > 0 million Any Device standing vertically, process connection on bottom Input Relative and absolute pressure Measuring range (bar) 0 to 0 to.6 0 to.5 0 to 4 0 to 6 0 to 0 0 to 6 0 to 5 Overload capacity (bar) - to 4 - to 6 - to 0 - to 6 - to 4 - to 40 - to 60 - to 00 Bursting pressure (bar) 6 0 5 4 6 60 00 50 Measuring range (bar) 0 to 40 0 to 60 Overload capacity (bar) - to 00 - to 00 Bursting pressure (bar) 50 Measuring range (bar) - to 0 - to 0.6 - to.5 - to - to 5 - to 9 - to 5 - to 4 Overload capacity (bar) - to 4 - to 6 - to 0 - to 6 - to 4 - to 40 60 00 Bursting pressure (bar) 6 0 5 4 6 60 00 50 All pressure transmitters are vacuum-proof Analog output Output signal Electrical current Output 405 Voltage Output 4 Output 45 Output 48 Output 40 Other outputs Jump response t 90 Burden 4to0mA 0.5 to 4.5 V to5v to6v 0to0V 4to0mA, wires 0.5 to 4.5 V three wires (ratiometrically 0 to 90% of the power supply) 0to0V three wires to 5 V three wires to 6 V three wires on request 5 ms R i (U B - 8 V) / 0.0 A 0 kω 0 kω 0 kω 0 kω
Data Sheet 40.00 Page /8 Measurement deviation Relative and absolute pressure Nominal measuring range (bar) 0 to 0 to.6 0 to.5 0 to 4 0 to 6 0 to 0 0 to 6 0 to 5 Non-linearity (% of full scale) 0. 0.5 0. Total error at +0 C 0.6 (% of full scale) Total error at -0 to +00 C.5 (% of full scale) Nominal measuring range (bar) 0 to 40 0 to 60 Non-linearity (% of full scale) 0. Total error at +0 C 0.5 (% of full scale) Total error at -0 to +00 C.0 (% of full scale) 0.6.5.4..0 Measuring range (bar) - to 0 - to 0.6 - to.5 - to - to 5 - to 9 - to 5 - to 4 Non-linearity (% of full scale) 0. 0.5 0. Total error at +0 C 0.5 (% of full scale) Total error at -0... +00 C. (% of full scale) Non-linearity based on limit point setting Includes: non-linearity, hysteresis, non-repeatability, deviation from initial and final values of measuring range Includes: non-linearity, hysteresis, non-repeatability, deviation from initial and final values of measuring range, thermal effect on initial value of measuring range and span Mechanical properties Materials Process connection Seal Diaphragm Enclosure Threaded sleeve Mx Connector Weight Instrument with process connection 50 (G/4) Stainless steel 04 The measuring system is welded with no seals 4 Stainless steel 6L Stainless steel 04 Stainless steel 0 PBT-GF0 80 g 4 Pressure transmitters with process connection 5 come with an FPM seal Ambient conditions Permissible temperatures with electrical connection 6, 5 or 6 Measuring material Environment Storage With electrical connation Measuring material Environment Storage At ambient temperature -50 C Restricted function Permissible relative humidity Operation Storage -40 to +5 C -40 to +5 C -40 to +5 C -40 to +5 C -40 to +00 C -40 to +00 C Stationary use only, danger of broken cable 00% rel. humidity, incl. condensation on the outer sleeve of the instrument 90% relative humidity, no condensation
Data Sheet 40.00 Page 4/8 Permissible mechanical loading Vibration strength Shock resistance Electromagnetic compatibility Interference emission Interference immunity Enclosure protection to EN 6059 with electrical connection (fixed cable and relative pressure measuring range) (fixed cable and absolute pressure measuring range) 6 (round plug M x ) 5 (Mini Metri Pack series 50) 5 (bayonet connector) 6 (terminal box) 4 0 g at to 000 Hz 50 g for ms 00 g for ms Class A Performance characteristic A IP66 IP67 IP66 IP67 IP67 IP65 Per IEC 60068-6 Per IEC 60068-7 Per EN66 4 Minimum connection line diameter 5 mm, maximum 7 mm Power supply Auxiliary power Terminal assignment Power supply U B for output 405 = 4 to 0 ma for output 4 = 0.5 to 4.5 V for output 45 = 0 to 0 V for output 48 = to 5 V for output 40 = to 6 V Residual ripple Reverse polarity protection Power consumption Circuit Electrical connection = Fixed cable 6 = Round plug M x 5 = Mini Metri Pack series 50 5 = Bayonet connector 6 = Terminal box See page 6/8 8 to 0 V DC, nominal voltage 4 V DC 5V DC ± 0.5 V, nominal voltage 5 V DC.5 to 0 V DC, nominal voltage 4 V DC 8 to 0 V DC, nominal voltage 4 V DC 8 to 0 V DC, nominal voltage 4 V DC Peak voltages must not exceed or fall below the values specified for the supply voltage yes 5 ma SELV 4-core cable, PVC, length m (other lengths available on request) 4-pin, A-coded Mini Metri Pack series 50 DIN 7585 A -. DIN 750 Form A 5 5 Conductor cross-section.5 mm
Data Sheet 40.00 Page 5/8 Electrical connection Connection Terminal assignment Devices with -wire output Power supply for output 4 5 V DC for output 45.5 to 0 V DC for output 48 8 to 0 V DC for output 40 8 to 0 V DC Output 4 = 0.5 to 4.5 V, ratiometric 45 = 0to0V 48 = to 5 V 40 = to 6 V Devices with wire output Power supply for output 405 8 to 0 V DC U B 0V S- S+ U B 0V Cable white + brown - brown - yellow + white + brown - 4 6 Mx + + + - 5 Mini Metri Pack + - - + + - 5 Bayonet + + + 6 Terminal box L+ L- - + L+ L- Output 405 = 4...0 ma, wire Impressed current 4 to 0 ma in power supply voltage S- S+ white brown + - + - + + -
Data Sheet 40.00 Page 6/8 Dimensions 5 Mx ø.6 46 / 48* 8.7 45 / 47* 5.5 4 5 9 56 / 54* 5 9 Pg 9 6 5 5 6 50 504 5 ø5 ø9.5 G/4 ø.5 ø6 ø7.5 6 ø.5 /4-8 NPT G/ ø 9 G /4 8.8 /4-8 NPT.5.6 G /4 0.6 8.5 h 0. ø 5.5 5 56 56 0 G/4 Profiled seal G/4 ø.5 ø9.5.5 ø9.5 7/6-0 UNF 4.5 ø.5 7 7 7/6-0 UNF with internal valve core depresser ø ø 7.5 4.6 G / h 0. SW 7/6-0 UNF ø 6
Data Sheet 40.00 Page 7/8 Order details () Basic type 4000 JUMO MIDAS S05 pressure transmitter () Basic type extensions 000 None 999 Special design () Input 454 0....0 bar relative pressure 455 0....6 bar relative pressure 456 0....5 bar relative pressure 457 0... 4 bar relative pressure 458 0... 6 bar relative pressure 459 0... 0 bar relative pressure 460 0... 6 bar relative pressure 46 0... 5 bar relative pressure 46 0... 40 bar relative pressure 46 0... 60 bar relative pressure 478 -... 0 bar relative pressure 479 -... 0.6 bar relative pressure 480 -....5 bar relative pressure 48 -... bar relative pressure 48 -... 5 bar relative pressure 48 -... 9 bar relative pressure 484 -... 5 bar relative pressure 485 -... 4 bar relative pressure 488 0....0 bar absolute pressure 489 0....6 bar absolute pressure 490 0....5 bar absolute pressure 49 0... 4 bar absolute pressure 49 0... 6 bar absolute pressure 49 0... 0 bar absolute pressure 494 0... 6 bar absolute pressure 495 0... 5 bar absolute pressure 505 0... 40 bar absolute pressure 998 Special measuring range for absolute pressure 999 Special measuring range for relative pressure (4) Output 405 4 to 0 ma wires 4 0.5 to 4.5 V wires 45 0 to 0 V wires 48 to 5 V wires 40 to 6 V wires (5) Process connection (not front-flush) 50 G /4 to DIN EN 87 504 G / to DIN EN 87 5 /4-8 NPT to DIN 87 5 G/4 to DIN 85 T 56 7/6-0 UNF 56 7/6-0 UNF inside, with valve opener (6) Process connection material 0 Stainless steel (7) Electrical connection Fixed cable 6 Round plug M 5 Mini Metri Pack series 50 5 Bayonet connector 6 Terminal box Available on request
Data Sheet 40.00 Page 8/8 (8) Extra codes 000 None 59 Throttle in pressure channel 64 Free of oil and grease 60 Larger channel hole () () () (4) (5) (6) (7) (8) Order code / - - - - - / Sample order 4000 / 000-459 - 405-504 - 0-6 / 000 Accessories Designation Sales no. 4-pin cable connector (straight) M x with m PVC cable 40/00404585 4-pin angle box M x with m PVC cable 40/004094