JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

Similar documents
JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

JUMO tecline Ci-S. Inductive conductivity and temperature sensor for general process engineering. Installation Instructions T94Z001K000

JUMO tecline CR-4P Conductive 4-Electrode Conductivity Sensor

JUMO tecline CR Electrolytic Conductivity Cells in stainless steel or titanium

Inductive conductivity meter

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications

ph-kompaktelektrodensystem sensopac CPA 320

Digital ph transmitter

Digital ph transmitter

Insertion magnetic inductive flowmeter

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

Inductive conductivity meter

JUMO MIDAS S05 Pressure transmitter Type

Conductivity Measuring Sensor InduMax H CLS 52

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Cleanfit CPA471. Technical Information. Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

JUMO BlackLine Lf-GT / -EC electrolytic 2-electrode conductivity cells

Electromagnetic Flow Monitor magphant

Diaphragm seal with threaded connection Plastic version Model

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

JUMO ecotrans Lf 01/02

Conductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands

Immersion fittings. Brief description. Installation options Standard. Series Page 1/7. Data Sheet

OPTIFLUX 6000 Technical Datasheet

JUMO PEKA Process Connection Adapter

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice

Indumax P CLS50. Technical Information. Highly resistant, inductive conductivity sensor for standard, hazardous and high-temperature applications

Pressure transmitter for elevated media temperatures

ATEX/IECEx RTD temperature probe

Automatic sensor lock-gate for extreme applications with ceramic sealing to the proces

Automatic sensor lock-gate for extreme applications with ceramic sealing to the proces

JUMO flowtrans DP R. Meter run R01 and orifice plate R02. Applications. Brief description. Special features. Customer benefits.

Probe holders for analytical probes

Cleanfit H CPA475. Technical Information. Retractable assembly for ph, ORP measurement under sterile conditions

Operating Instructions (from serial number 3000)

ABB MEASUREMENT & ANALYTICS DATA SHEET. AC200 Series Industrial 2-electrode conductivity cells with rapid temperature response

Technical Information Cleanfit CPA472D

Magnetic Inductive Flow

JUMO heattherm Type Protection temperature limiter, as a panel-mounting thermostat Compensated for ambient temperature

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

Corrosion Resistant and Ultra-Pure Rotameters for Accurate Measurement of Liquids and Gases

JUMO dtrans p20 DELTA

Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam

FLOWX3 F3.60M.S Insertion Magmeter

Conductivity Measuring Cells ConduMax W CLS 19

Ultrasonic filling level sensor UFM 200 / 600 C2 / C4 / R / MD

Electromagnetic Flow Meter Owner s Manual HARDWARE

SE 655 N-GEFFT0AM Digital Toroidal Conductivity Sensor

Cleanfit W CPA450. Technical Information. Retractable assembly for 12 mm sensors for DO/pH/ORP measurement

Praher S4 Ball Valve. manual valves. Materials. Sizes. Pressure Rating. Features. Connections. Valve Dimensions. Actuation.

Praher S4 Ball Valve. manual valves. Materials. Sizes. Pressure Rating. Features. Connections. Valve Dimensions. Actuation.

INSERTION flowmeter with paddle wheel, ELEMENT design

Inline version with application-specific process adaptation

Magnetic-Inductive Flow Meter FMI

Pressure transmitters for industrial applications Type MBS 4510

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

JUMO MIDAS S05. OEM Pressure Transmitter Universal. Applications. Brief description. Customer benefits. Special features

Explosion-protected surface-mounting Thermostat ATH-Ex Series

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

Hydrostatic. Continuous level measurement. Overview Page 186 VEGABAR series 60 Page 188 VEGAWELL 52 Page 192 Accessory Page 194.

JUMO MIDAS Pressure transmitter

Metso Conductivity for sensor series 9400 and 9500

Magnetic-Inductive Flow Meter FMQ

Magnetic-Inductive flow Meter fmi

Magnetic Inductive Flowmeter EP / UMF2 (B)

INSERTION flow sensor for continuous flow measurement

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

GEMÜ 205 Electrically operated solenoid valve

Pressure Transmitter JUMO dtrans p30 Type

INSERTION Adaptor for analysis

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter

Level Limit Switch liquiphant FTL 365 / FTL 366

Electromagnetic Flow Monitor magphant

Measuring Cells for free chlorine, chlorine dioxide, ozone

Pressure transmitter for general purpose Type MBS 1700 and MBS 1750

Signet 2551 Magmeter Flow Sensor

Continuous level sensor NSK

Technical Information Cleanfit CPA451

Flow-Through Fitting ARF 215

N086, N186, N786. Pressure retaining valve, Plastic

JUMO tecline HD ph and JUMO tecline HD Rd

EPI Applications. Features

Liquid Analysis. Innovative solutions for the highest requirements

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

Servo-operated 2/2-way solenoid valves Type EV220A

ETP80. Electronic Transmitter for Pressure, Differential Pressure and Level

Cleanfit P CPA472D. Technical Information. Retractable process assembly for ph, ORP and other industry sensors Heavy-duty version

Plastic tube variable area flowmeter for liquids and gases

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Cable resistance thermometer Model TR40

JUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see "Technical data")

Modular resistance thermometer - Quicktemp TP60/TW39...T500 -

Level Limit Switch liquiphant FTL 360 / FTL 361

JUMO tecline H2O2 JUMO tecline PAA Sensor for hydrogen peroxide and peracetic acid

In-line diaphragm seal with sterile connection For sanitary applications Model , aseptic connection per DIN 11864

Type 561/562 Cone Check Valve

Flow measurement FlexFlow PF20H Hygienic flow sensor

Horizontal And Vertical Centrifugal Pumps

Thermal flow sensor TFS-35

Transcription:

Data Sheet 22943 Page 1/9 JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering Brief description The sensor detects the electrolytic conductivity of a process liquid. It uses the inductive principle of measurement. Because it uses the inductive method of measurement rather than the conductive 2-pin or 4-pin measurement method, the sensor is virtually maintenance-free. The measuring accuracy is practically unaffected by accumulations and grease or oil film on the surface of the sensor. A (Pt1) temperature sensor acquires the process temperature at the same time. The temperature sensor can either be exposed in a stainless steel pocket (ultra-fast response) or be located right inside the plastic body (with PVDF, only the internal option is possible). Internal installation is advisable if the sample media could chemically attack the stainless steel pocket. The standard sensor body material is polypropylene (PP). PVDF is also available as an alternative. A vast number of process connections are available to ensure system flexibility, even to provide spare equipment for older instruments. The JUMO ecoline Ci sensor is designed for connection to the JUMO AQUIS 5 Ci transmitter, as per data sheet 2.2566. Typical areas of application: The sensor is primarily designed for use in water engineering systems. Typical areas of application include general water engineering (drinking water and wastewater), air-conditioning and cooling plants, dilution monitoring in cooling towers, flushing tanks, carwashes, sea water desalination (inlet), monitoring swimming pool water, etc. There is an immersion variant that can be used in open channels and containers. Type 2.2943/1-... Product advantages: Practically maintenance-free conductivity measurement Materials are FDA/food-use approved A variety of process connection variants A fast-response temperature sensor A compact, proven sensor Type 22943/1-... with T-piece made from PVC

Data Sheet 22943 Page 2/9 Technical data Type 22943/1-... 22943/2-... 22943/3-... Conductivity measurement principle Inductive Conductivity meas. range... 1 µs/cm to... 2 ms/cm (depending on connected transmitter) Conductivity accuracy for measuring range: -1mS/cm -1mS/cm -5mS/cm -1mS/cm - 1 ms/cm - 2 ms/cm 1%.5%.5%.5% 1% 1% Cell constant k = 6.25 1/cm k = 4.65 1/cm Temperature sensor Pt1, Class A t 9 temperature a 6s 2min 1 min Permissible ambient temperature -1 to +6 C Permissible storage temperature -2 to +75 C Enclosure protection b IP68 Permissible medium temperature c In operation Momentary Permissible process pressure c at +2 C at +6 C at +8 C at -1 to +1 C Sensor material in contact with medium not in contact with medium Process connection Electrical connection Connection circuit Socket Socket material Cable material Cable lengths Permissible temperature Pressure [bar] 1 8 6 4 2 steel 1.431 (34), stainless steel 1.4571 (316ti), PP, EPDM steel 1.431 (34), PA6, PUR, FPM, PBT/PA, CR/NBR, CuZn see Order details / Dimensions -1 to +8 C +1 C ( 15 min) -1 1 bar 6bar 3bar min. -.1 bar 1 2 3 4 5 6 7 8 9 1 Temperature [ C] steel 1.431 (34), PP steel 1.431 (34), PA6, PUR, FPM, PBT/PA, CR/NBR, CuZn -1 to +1 C +11 ( 15 min) 1 bar 6bar 4bar min. -.1 bar Approvals/marks of conformity Materials in contact with the medium are approved for food use, are physiologically safe and are listed by the FDA. a EN 6751 b EN 6529 c Note: Temperature, pressure and sample medium affect the life of the cell! PVDF steel 1.448, PA6, PUR, PBT/PA, CR/NBR, CuZn JUMO ecoline Ci type inductive conductivity sensors are suitable for connection to JUMO AQUIS 5 Ci type inductive conductivity transmitters/controllers! non-detachable cable M12 socket, 8-pin CuZn, PA6.6 GF3, PUR outer sleeve: PUR see Order details -2 to +75 C Pressure [bar] 1 8 6 4 2-1 1 2 3 4 5 6 7 8 9 1 Temperature [ C]

Data Sheet 22943 Page 3/9 Principle of measurement The inductive method of measurement allows largely maintenance-free acquisition of specific conductivity, even in the toughest media conditions. Compared with the conductive method of measurement, problems such as electrode decomposition and polarization are practically non-existent. Conductivity is measured by an inductive probe. Sinusoidal AC voltage supplies the transmitter coil. Current is induced in the receiver coil, subject to the conductivity of the liquid to be measured. The current is proportional to the conductivity of the medium. Measurement section setup Instrument description Measuring cell The measuring cell consists of a hermetically sealed polypropylene (PP) or polyvinylidene fluoride (PVDF) body, with two measuring coils arranged inside it. A flow-through opening in the measuring cell allows the sample medium to pass through. Electrical isolation between the sample medium and the actual value output is inevitable, because of the principle of measurement. The measuring cell is extremely temperature and pressure stable. JUMO ecoline Ci, inductive conductivity and temperature sensor Cable (component part of JUMO ecoline Ci), standard length 1 m JUMO AQUIS 5 Ci, transmitter/controller for conductivity, concentration and temperature (1a) (4) exposed temperature sensor (1a) option: internal PP cell body measuring coils (4) liquid loop Exposed temperature sensor: The sensor in its stainless steel pocket reacts very quickly to changes in temperature. Internal temperature sensor: The sensor is integrated in the cell body. No metal comes into contact with the sample medium in this version (important for aggressive media). However, temperature acquisition is slower.

Data Sheet 22943 Page 4/9 Sensor details 4 Ø22 Ø 6.7 Guide slot A lug on the T-piece (see Accessories) fits into the 4 mm wide guide slot, thus ensuring that the sensor is correctly aligned to the direction of flow. Exposed temperature sensor This is the standard version. Material in contact with sample medium: stainless steel 1.4571 AISI 316ti and FPM. Internal temperature sensor Extra code 268. Material in contact with sample medium: PP, suitable for food use. PVDF sensor body Cell constant 4.65 1/cm. Not available for process connection 76 (immersion version). Process connection 168 for T-piece installations, PVC union nut (included among the items supplied) Process connection 169 for T-piece installations, stainless steel union nut (included among the items supplied)

Data Sheet 22943 Page 5/9 41 36.5 55 161 55 145 118 81 67 44.5 161 133 78 64 Type 22943/1-168... or -169... DN32 or DN4 Type 22943/1-67-... MK DN5 133 78 64 M12 socket, PBT / PA M16 screw-type cable gland IP68 protection (to.2 m), PBT / PA PP (4) 1.431 stainless steel, AISI 34 Type 22943/1-69-... 2" SMS

Data Sheet 22943 Page 6/9 Dimensions EL ~12 ±1 ~21 22 ø4 161 133 78 64 55 Type 22943/1-617-... or -616-... 2" clamp or 2 1/2" clamp ø4 ø44.5 M12 socket, PBT / PA M16 screw-type cable gland IP68 protection (to.2 m), PBT / PA PP (4) 1.431 stainless steel, AISI 34 Type 22943/1-76-... Immersion version

Data Sheet 22943 Page 7/9 Accessories / Mounting examples L D DN ø D L Material Maximum temperature Sales No. 32 4 98 2/439247 PVC 6 C 4 5 118 2/439249 32 4 88 2/449511 4 5 12 PP 8 C 2/449514 5 63 124 2/449516 T-piece made from PVC or PP suitable for process connections 168 and 169 ~11 ~6.5 ~4 ~22 ~37.5 ~78 ~64 49 66 81 DN5 DN65 DN8 Weld-on threaded adapter DN5, DIN 11851 Sales No. 2/852 suitable for process connection 67 The reducing T-piece shown, DIN, short, SSS, DN5/5, or DN65/5 or DN8/5, must be provided by the customer (not supplied by JUMO)! 18 18 57 6 1 +5 3 1 +5 ø18 3 ø18 ø1 ø165 ø125 ø165 DN32 flange suitable for process connection 76 Sales No. 2/83375 Material: PP DN5 flange suitable for process connection 76 Sales No. 2/83376 Material: PP

Data Sheet 22943 Page 8/9 Order details: JUMO ecoline Ci Inductive conductivity and temperature sensor 22943 Basic type JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering Basic type extension 1 PP sensor body, external temperature sensor (standard) 2 PP sensor body, internal temperature sensor 3 PVDF sensor body, internal temperature sensor Process connection 168 for T-piece installations, with PVC union nut 169 for T-piece installations, with stainless steel union nut 67 MK DN5 milk cone a 616 2" clamp a 617 2 1/2" clamp a 69 2" SMS a 76 Immersion version b (4) Immersion length (EL) without 5 EL = 5 mm c 1 EL = 1 mm c 15 EL = 15 mm c 2 EL = 2 mm (max. value) c (5) Electrical connection 21 Fixed cable with M12 cable socket (6) Length of fixed cable 1 1 m (standard) 2 2 m 3 3 m (7) Extra codes none a Without mounting material (union nuts, retaining clamps, etc.) b For basic type extension 1 or 2 only. c For process connection 76 only. (4) (5) (6) (6) Order code / - - - - /... Order example 22943 / 1-168 - - 21-1 /

Data Sheet 22943 Page 9/9 Stock versions (delivery 3 working days after receipt of order) Type Designation Sales No. 22943/1-168--21-1/ 22943/2-168--21-1/ PP, external temperature sensor, with PVC union nut, 1 m fixed cable PP, internal temperature sensor, with PVC union nut, 1 m fixed cable 2/548189 2/55695 Production versions (delivery 1 working days after receipt of order) Type Designation Sales No. 22943/1-67--21-1/ PP, external temperature sensor, MK DN5, 1 m fixed cable 2/55665 22943/1-76-1-21-1/ PP, external temperature sensor, immersion version 1 m, 1 m fixed cable 2/556316 Accessories (delivery 3 working days after receipt of order) Designation Sales No. Weld-on threaded adapter DN5, DIN 11 851(mating piece for process connection 67) 2/852 PVC DN32 T-piece, including threaded insert (mating piece for process connection 168 or 169) 2/439247 PVC DN4 T-piece, including threaded insert (mating piece for process connection 168 or 169) 2/439249 PP T-piece, DN32 a (mating piece for process connection 168 or 169) 2/449511 PP T-piece, DN4 a (mating piece for process connection 168 or 169) 2/449514 PP T-piece, DN5 a (mating piece for process connection 168 or 169) 2/449516 G1 1/2 union nut, PVC 2/439199 G1 1/2 union nut, stainless steel 2/45239 DN5 grooved union nut, DIN 11 851 2/343368 SMS DN2" grooved union nut 2/345162 DN32 flange b, PP material 2/83375 DN5 flange b, PP material 2/83376 Calibration adapter for inductive conductivity measurement, type 22711/21 2/543395 a With rotation protection - the measuring cell can only be installed in the correct alignment. b In conjunction with sensor with process connection 76 (immersion version) only. Note The following are required for the initial commissioning of the sensor and transmitter/controller or when replacing components: - Transmitter/controller e. g. JUMO AQUIS 5 Ci, data sheet 2.2566 - JUMO ecoline Ci inductive conductivity and temperature sensor - Calibration adapter for inductive conductivity measurement, type 22711/21, data sheet 2.2711