JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

Similar documents
JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

JUMO MIDAS S05 Pressure transmitter Type

JUMO MIDAS S07 MA. OEM Pressure Transmitter - Maritime Approved. Applications. Brief description. Special features.

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications

JUMO MIDAS S05. OEM Pressure Transmitter Universal. Applications. Brief description. Customer benefits. Special features

JUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see "Technical data")

JUMO dtrans p20 DELTA

Pressure transmitter for elevated media temperatures

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter

Pressure Transmitter JUMO dtrans p30 Type

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

JUMO dtrans p35. Pressure Sensor with IO-Link. Application. Brief description. Customer benefits. Special features

JUMO dtrans p02. Pressure transmitter. General application. Approvals/marks of conformity. Data Sheet Page 1/6. II 1/2G Ex ia IIC T6 Ga/Gb

JUMO PEKA Process Connection Adapter

Pressure Transmitter JUMO dtrans p30 Type

JUMO MIDAS Pressure transmitter

SITRANS P measuring instruments for pressure

Pressure transmitter JUMO dtrans p02

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Pressure transmitter for industrial applications Type MBS 4510

Pressure transmitters for industrial applications Type MBS 4510

Pressure measurement PP20H Fully welded hygienic pressure sensor with flush membrane

JUMO tecline CR-4P Conductive 4-Electrode Conductivity Sensor

Pressure transmitter for general applications Model S-10, standard version Model S-11, flush diaphragm

Electronic Pressure Switch EDS 3000

fluid technology temperature sensors 1600 intelligent temperature sensor membrane keyboard, USB opto interface

Beck. The differential pressure transmitter for air with IP65

DCT 533. Industrial Pressure Transmitter with IO-Link Interface. Stainless Steel Sensor

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

Pressure Transmitters for Sanitary Applications Model SA-11

Differential Pressure and Flow meters Accessories for the Media Series

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Differential Pressure Sensors

JUMO ecotrans Lf 01/02

SATRON VTe pressure transmitter

Pressure transducer DMU 01K Compact version

In-line diaphragm seal with sterile connection For sanitary applications Model , aseptic connection per DIN 11864

Differential Pressure Sensors

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

2-Color Display High-Precision Digital Pressure Switch

Pressure transmitter PASCAL CV4

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

Insertion magnetic inductive flowmeter

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

Industrial Pressure Transmitters

Mini Pressure Transmitter HA7

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

Pressure Sensors. for liquid and gaseous media

Operating instructions Flow monitors SI6600 SI6700 SI /02 01/2011

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Compact Pressure Transmitter DAN-HH

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Flow measurement FlexFlow PF20H Hygienic flow sensor

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

Pressure transmitter COMPACT ECOnomic

Differential Pressure Sensors

Flush-mounted pressure and level transmitters - KERAMESS KS series 100/101 -

Temperature Sensor without thread

Diaphragm seal with sterile connection With clamp connection (Tri-clamp) Models , and

Pressure transmitter for general purpose Type MBS 1700 and MBS 1750

Electronic pressure switch with integrated analogue output

Diaphragm seal with sterile connection With union nut (milk thread fitting) Models , , and

Pressure Transmitter. Pressure transmitter with compact design Model EDC-K. Electronic. Applications. Special Features.

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

BTE2000 / PTE2000 Series Precision stainless steel pressure transmitters

OEM Pressure Transmitters

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

Pressure transmitter for industrial applications Type MBS 4500

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Diaphragm pressure gauge, flush For sanitary applications, NS 100 Model PG43SA-D, with integrated diaphragm element monitoring

Digital display Pressure range ON/OFF output Linear output Model

Electronic pressure switch with two switching outputs

2-Color Display High-Precision Digital Pressure Switch

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

Pressure transmitter UNIVERSAL CA

FPT Applications. Features

High-quality pressure sensor with mounted diaphragm seal With clamp connection Model DSS22T

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250

Inductive conductivity meter

Diaphragm pressure gauge, flush For sanitary applications Model PG43SA-S, NS 100

Continuous level sensor NSK

Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050

OPTISWITCH 6500 C Technical Datasheet

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

Flush-mounted pressure and level transmitters - TPF series 100/101 -

OPTISWITCH 6500 C Technical Datasheet

Digital Pressure Gauge / Pressure Switch

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Diaphragm seal with sterile connection For sanitary applications Models , , and , threaded connection

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

Electronic Pressure Switches

Transcription:

Data sheet 405052 Page 1/10 JUMO DELOS SI Precision pressure transmitter with switching contacts and display Application Food & pharma CIP/SIP systems Machine and system construction Air conditioning and refrigeration system construction Brief description The JUMO DELOS SI high-precision, electronic pressure switch with analog output meets technical requirements relevant to hygiene. In a readily cleanable design and with a front-flush, sealfree measuring system, it is specifically geared to hygienic process safety standards and has been engineered and certified in compliance with EHEDG guidelines. The nominal measuring ranges set at the factory extend from 400 mbar to 60 bar. They can be rescaled in the ratio 1:4, allowing the user to perform several measurement tasks with just one measuring instrument. The following output variants are available, depending on the application: 1 PNP or 2 PNP switching outputs or 1 PNP switching output and an analog output signal. The process pressure is visualized by a large, positively lit LC display, which changes from an amber color to red, as an alarm function, if the nominal measuring range is exceeded (6.25 % according to NAMUR). Configuration can simply be performed on the measuring instrument, or by using the more convenient setup program. The enclosure can be rotated +/-160 to make it easier to read, and the display can be rotated 180 for overhead mounting. A high-temperature variant is available for hot media up to 200 C (CIP and SIP cleaning systems). Type 405052 Customer benefits Process safety An hygienic design, with parts in contact with the medium made from stainless steel. The system has no dead zones, which prevents microbial contamination and ensures maximum process safety for hygienic processes. Uncomplicated and time-saving Save time with easy, local measuring instrument configuration or configuration via a more convenient setup program. Flexible The enclosure can be turned +/-160 and the display rotated 180 for user-friendly and individual alignment of the measuring instrument for optimum readability, configuration and electrical installation in any mounting position, as well as for running an auto-zero function. Key features Linearity from 0.1 % of FS Sclaing of measuring range 1:4 Large, brilliant two-color display with alarm function Time-saving and simple configuration on the instrument or via a more convenient setup program Flexible mounting variance by rotating the display (180 ), followed by auto zeroing Enclosure can be turned (+/-160 ) to improve readability Option for increased medium temperature up to 200 C (SIP and CIP capability) Approval/approval marks (see Technical Data)

Data sheet 405052 Page 2/10 Technical data General information Reference conditions DIN 16086 and DIN EN 60770 Sensor system Silicium sensor with stainless steel separating diaphragm Pressure transfer means Synthetic oil (silicon oil), FDA-compliant oil Permissible load changes > 10 million Location Mounting position Any Position-dependent zero point offset Device standing upright, process connection on bottom Basic type 000 standard 1 mbar Basic type 004 high-temperature design 10 mbar Display Positively lit display Alignment Display can be rotated 180 via software Enclosure rotatable ±160 (use the combination tool supplied) Size Display field 16 26 mm, font size 7 mm, 2 4-digit Color Normal operation: amber-colored Switching state display K1, K2 Measuring unit mbar, bar, kpa, MPa, psi, % Operation Local Via control element under the screw plug with combination tool or 0.5 3 screwdriver or 2AF hex key Setup interface Pin 5 of the M12 1 round plug Input Relative pressure Nominal measuring ranges start at 0 bar. Nominal measuring range 0.4 1 4 10 25 60 Overload capacity a 4 16 40 100 240 Bursting pressure 2 5 20 50 125 300 Nominal measuring range -0.4 to +0.4-1 to +1-1 to +3-1 to +9-1 to +24 Overload capacity a 4 16 40 100 Bursting pressure 2 5 20 50 125 Absolute pressure Nominal measuring ranges start at 0 bar. Nominal measuring range 0.4 1 4 10 25 60 Overload capacity a 4 16 40 100 240 Bursting pressure 2 5 20 50 125 300 bar bar bar a All measuring ranges can be overloaded to -1 bar (vacuum-proof). Outputs All analog outputs in 3-wire technology/switching outputs: open collector, PNP switching Analog output Current Output 475 Output 476 Voltage Output 477 Step response time (analog input) T 90 Switching output Output 470, 475, 476 or 477 4 to 20 ma (and 1 PNP switching output) 0 to 20 ma (and 1 PNP switching output) 0 to 10 V (and 1 PNP switching output) 100 ms 1 PNP switching output

Data sheet 405052 Page 3/10 Output 471 2 PNP switching outputs Switching type Break contact/make contact Switching function Window/hysteresis Switching capacity Voltage drop from U B PNP 2V Contact rating ON 250 ma/off 1mA Switching cycles > 10 million Response time 20 ms Short-circuit proof Yes Current load check Pulse period 2 s; T ON 40 ms Periodic protective circuit with overcurrent f=0.5hz Display: Err3 switching output K 1, Err4 switching output K 2 Setting range Analog output Measurement range scaling (turn down) 1:4 Switching output Switching point Configurable in the nominal measuring range (> reset point) Reset point Configurable in the nominal measuring range (< switching point) Hysteresis Configurable in the nominal measuring range Input damping 0 to 99.99 s Input delay 0 to 99.99 s Burden Current 4to20mA, three-wire R L (U B -6.5 V) 0.022 A (Ω) 0to20mA, three-wire R L (U B -6.5 V) 0.022 A (Ω) Voltage DC0to10V, three-wire R L 10 KΩ Mechanical properties Process connection Material Stainless steel 316L Surface Ra 0.8 µm Process seal All flange connections are welded and therefore have no seals! Process connection 521, 523, 571, 576, 652 FPM as standard Process connection 575 FPM as standard, O-ring at front; FDA-compliant Process connection 997 JUMO PEKA FPM, VMQ, silicon EPDM; FDA-compliant, options see data sheet 409711 Measuring diaphragm Material Stainless steel 316L Surface Ra 0.8 µm Enclosure Material Stainless steel 316L Surface Ra 0.8 µm Threaded sleeve M12 1 Stainless steel 316L Enclosure seal VMQ silicon; FDA-compliant Display PA (polyamide) Control element screw plug Material Aluminum 3.2315 Surface Eloxal coating Seal VMQ silicon; FDA-compliant Weight 200 g with process connection 504, (G 1/2)

Data sheet 405052 Page 4/10 Ambient conditions Permissible temperatures Medium -25 to +100 C (135 C max 1 hour/day; no function here) For basic type extension 004-25 to +200 C Environment -25 to +75 C Ambient temperature -50 C Restricted function: stationary use only, danger of broken cable, display does not function Storage -40 to +85 C Permissible relative humidity In operation 100 % rel. humidity, including condensation of instrument outer sleeve Storage 90 % rel. humidity, no condensation Permissible mechanical loading Vibration resistance a 20 g, 10 to 2000 Hz Shock resistance b 50 g for 11 ms/100 g for 1 ms Electromagnetic compatibility With 4-pin connecting cable and grounded enclosure only! Interference emission c Class B Interference immunity c Industrial requirements Protection d IP67 a IEC 60068-2-6 b IEC 60068-2-27 c IEC 61326-2-3 d EN 60529 (with suitable mating piece when connected) Accuracy Relative pressure Nominal measuring ranges start at 0 bar. Nominal measuring range 0.4 1 4 10 25 60 bar Linearity a 0.15 0.15 0.1 0.1 0.1 0.1 % of FS of NMR Accuracy at +20 C b 0.35 0.3 0.25 0.25 0.25 0.25 % of FS of NMR Accuracy at -20 to +75 C c 0.7 0.6 0.5 0.5 0.5 0.5 % of FS of NMR Nominal measuring range -0.4 to +0.4-1 to +1-1 to +3-1 to +9-1 to +24 bar Linearity a 0.15 0.15 0.1 0.1 0.1 % of FS of NMR Accuracy at +20 C b 0.35 0.3 0.25 0.25 0.25 % of FS of NMR Accuracy at -20 to +75 C c 0.7 0.6 0.5 0.5 0.5 % of FS of NMR Absolute pressure Nominal measuring range start at 0 bar. Nominal measuring range 0.4 1 4 10 25 60 bar Linearity a 0.15 0.15 0.1 0.1 0.1 0.1 % of FS of NMR Accuracy at +20 C b 0.35 0.3 0.25 0.25 0.25 0.25 % of FS of NMR Accuracy at -20 to +75 C c 0.7 0.6 0.5 0.5 0.5 0.5 % of FS of NMR Long-term stability d 0.2% with reference conditions as per EN 61298-1 a Linearity based on limit point setting b Includes: linearity, hysteresis, repeatability, deviation from initial and final values of measuring range c Includes: linearity, hysteresis, repeatability, deviation from initial and final values of measuring range, thermal effect on initial value of measuring range and span d EN 61298-1

Data sheet 405052 Page 5/10 Auxiliary power Voltage supply U a B Nominal voltage DC 24 V 0 to 20 ma, three-wire, output 476 DC 12 to 30 V 4 to 20 ma, three-wire, output 475 DC 12 to 30 V 0 to 10 V, three-wire, output 477 DC 14 to 30 V Less than the permitted voltage supply Display Err 5 More than the maximum voltage supply The specified properties are no longer met. > DC 34 V Reverse polarity protection YES Power consumption 45 ma without load, 545 ma with load 2 PNP Electrical connection Round plug M12 1, 4-pin, A-coded (for assignment see "Connection diagram ) Circuit SELV a Residual ripple: Peak voltages must not exceed or fall below the values specified for the voltage supply! Approval/marks of conformity Mark of conformity Testing laboratory Certificate/ Certification number Test basis Valid for EHEDG TUM MAK No. 03/2006 Document No. 8 Process connection 997 JUMO PEKA

Data sheet 405052 Page 6/10 Block diagram Pressure Interface Setup program Shaft encoder Operation: turning and pressing Type 405052 Display 2 4 characters, 2-color Switching output 1 Open collector max. 250 ma Analog output 0(4) to 20 ma or DC 0 to 10 V Voltage supply DC 12(14) to 30 V Switching output 2 Open collector max. 250 ma Connection diagram Output 470 Output 471 Output 475-477 1 PNP switching output 2 PNP switching outputs 1 PNP switching output + 1 analog output 3 5 4 2 Voltage supply 1 K1 L+ L- 3 5 4 2 Voltage supply 1 Voltage supply 1 L+ DC 12(14) to 30 V 1 L+ DC 12(14) to 30 V 1 L+ DC 12(14) to 30 V 3 L- (GND) 3 L- (GND) 3 L- (GND) Output Output Output K1 K2 L+ L- 3 5 4 2 1 K1 L+ L- 4 K1 Highside open collector max. 250 ma 2 K2 Highside open collector max. 250 ma 2 analog 0(4) to 20 ma/0 to 10 V 2 nc 4 K1 4 K1 Highside open collector max. 250 ma 5 Interface 5 Interface 5 Interface Color assignment: M12 1 round plug 1 bn Brown 4 bk Black The color assignment applies only 2 wh White 5 gy Gray to A-coded standard cables. 3 bu Blue

Data sheet 405052 Page 7/10 Dimensions 35 Ø42 M 12x1 75 40 30 Type 405052/000-... Type 405052/004-... Process connections, not front-flush 504 511 521 523 E E E E 20 31 15 26 12 A 23.5 14 B 25.5 1/4-18 NPT G 1/4 G 1/2 G 1/2 19 G 1/2 15 1/4-18 NPT 10.4 0.1 Ø 19 G 1/4 1.5 12 0.1 Ø 27 G 1/2 2.5 14 Ø7 A = Profile seal DN G 1/4 B = Profile seal DN G 1/2 E = 27 AF

Data sheet 405052 Page 8/10 Dimensions Process connections, front-flush 571 575 576 F F G C C D G 3/4 16 32 Ø 24 G 3/4 9 20.5 34 H Ø 30 G 1 7 20.5 I 35 G 3/4 G 3/4 Ø 24.5 G 1 Ø 30.5 16 20.5 16 13 20.5 17.5 14 C = Profile seal DN G 3/4 G = 41 AF J = O-ring 29.82 2.62 D = Profile seal DN G 1 H = O-ring 20.35 1.78 F = 32 AF I = O-ring 26.7 1.78 603 to 607 612 to 616 D 2 3 15 L 1 D 1 D 3 D 1 D 2 D 4 Process connection DN Ø D 1 Ø D 2 Ø D 3 Ø D 4 L 1 Process connection DN DIN 32676 DN (inch) Nominal size ISO 2852 Ø D 1 Ø D 2 603 20 36.5 30 RD 44 1/6 54 13 612 20 12 27.5 34 604 25 44 35 RD 52 1/6 63 15 15 12.7 606 40 56 48 RD 65 1/6 78 15 17.2 607 50 68.5 61 RD 78 1/6 92 16 21.3 613 25 1?? 25 43.5 50.5 32 1.5?? 33.7 40 38 616 50 2?? 40 56.5 64 51 623 652 997 hex 27 Ø 45 15 Ø 35 11 Ø19 Ø26 Ø40 3 21 31 RD52 x 1/6 Ø 55 Ø 63 J Process connection for adapter system certified by EHDEDGJUMO PEKA (see data sheet 409711)

Data sheet 405052 Page 9/10 Order details (1) Basic type 405052/000 JUMO DELOS SI - Precision pressure transmitter with switching contacts and display a 405052/004 JUMO DELOS SI - Precision pressure transmitter with switching contacts and display for increased measuring material temperatures up to 200 C b 405052/999 JUMO DELOS SI - Precision pressure transmitter with switching contacts and display, special version (2) Input 447-400 to +400 mbar relative pressure 449-1 to +1 bar relative pressure 452 0 to 400 mbar relative pressure 454 0 to 1 bar relative pressure 457 0 to 4 bar relative pressure 459 0 to 10 bar relative pressure 461 0 to 25 bar relative pressure 463 0 to 60 bar relative pressure 481-1 to +3 bar relative pressure 483-1 to +9 bar relative pressure 485-1 to +24 bar relative pressure 486 0 to 400 mbar absolute pressure 488 0 to 1 bar absolute pressure 491 0 to 4 bar absolute pressure 493 0 to 10 bar absolute pressure 495 0 to 25 bar absolute pressure (3) Output 470 1 PNP switching output 471 2 PNP switching outputs 475 1 PNP switching output and 1 analog output 4 to 20 ma c 476 1 PNP switching output and 1 analog output 0 to 20 ma c 477 1 PNP switching output and 1 analog output 0 to 10 V c (4) Process connection 504 G 1/2 EN 837 511 1/4-18 NPT EN 837 521 G 1/4 DIN 3852-11 523 G 1/2 DIN 3852-11 571 G 3/4 front-flush EN ISO 228-1 575 G 3/4 front-flush with 2-way seal 576 G 1 front-flush with 2-way seal 603 Taper socket with union nut DN 20 DIN 11851 (dairy screw connection) d 604 Taper socket with union nut DN 25 DIN 11851 (dairy screw connection) d 606 Taper socket with union nut DN 40 DIN 11851 (dairy screw connection) d 607 Taper socket with union nut DN 50 DIN 11851 (dairy screw connection) d 612 Clamp DN 10, 15, 20 DIN 32676 613 Clamp DN 25, 32, 40 DIN 32676 616 Clamp DN 50 DIN 32676, 2 ISO 2852 619 Clamp DN 15 DIN 32676, 3/4 ISO 2852 623 Small flange DN 25 DIN 28403 652 Tank connection with grooved union nut DN 25 e 997 JUMO PEKA with EHEDG approval f 998 Suitable for connection to diaphragm seal (5) Process connection material 20 CrNi (stainless steel)

Data sheet 405052 Page 10/10 (6) Electrical connection 36 Round plug M12 1 (7) Measuring system filling medium 01 Silicon oil 12 FDA-compliant oil (8) Extra codes 000 None 100 Customized setting (specify required setting in plain text) 452 Parts in contact with the medium are electropolished, surface roughness Ra 0.8 µm 591 Throttle in pressure channel 624 Free of oil and grease 691 Improved humidity/vibration protection a This JUMO product is licensed under United States and Canadian patents. Purchasers of the JUMO product outside of the United States and Canada should advise JUMO of any planned sales of products incorporating the JUMO product into the United States and Canada. b Measuring devices for increased measuring material temperatures can only be delivered with process connection 571, 575, 576, 603, 604, 606, 607, 612, 613, 623, 652, 997. c Factory setting - the analog output can be freely configured. d Union nut is included in delivery. e Welding socket, seal and groove union nut are included in delivery. f For suitable process connection adapters, see data sheet 409711. (1) (2) (3) (4) (5) (6) (7) (8) Order code - - - - - - / Order example 405052/000-459 - 471-504 - 20-36 - 01 / 000 Stock versions Delivery in 3 working days after receipt of order Type Version Sales no. 405052/000-459-475-504-20-36-01/000 0 to 10 bar rel., 1 PNP switching output and 4 to 20 ma, G 1/2 00520630 405052/000-449-475-504-20-36-01/000-1 to +1 bar rel., 1 PNP switching output and 4 to 20 ma, G 1/2 00523317 405052/000-454-475-504-20-36-01/000 0 to 1 bar rel., 1 PNP switching output and 4 to 20 ma, G 1/2 00527029 405052/004-491-475-504-20-36-01/000 Increased measuring material temperature, 0 to 4 bar abs., 00527725 1 PNP switching output and 4 to 20 ma, G 3/4 405052/000-457-475-504-20-36-01/000 0 to 4 bar rel., 1 PNP switching output and 4 to 20 ma, G 1/2 00528156 405052/000-452-475-504-20-36-01/000 0 to 400 mbar rel., 1 PNP switching output and 4 to 20 ma, G 1/2 00528746 405052/000-461-475-504-20-36-01/000 0 to 25 bar rel., 1 PNP switching output and 4 to 20 ma, G 1/2 00528994 405052/000-452-475-997-20-36-01/000 0 to 400 mbar rel., 1 PNP switching output and 4 to 20 ma, JUMO PEKA 00530067 405052/000-483-475-997-20-36-01/000-1 to +9 bar rel., 1 PNP switching output and 4 to 20 ma, JUMO PEKA 00533816 Accessories Article Sales no. PC interface cable including USB/TTL converter a 00456352 Y transmitter cable, 5 pole a 00507861 Combination tool 00526614 Cable connector, straight, 4 pole, M12 1, 2 m PVC cable 00404585 Cable connector, angled, 4 pole, M12 1, 2 m PVC cable 00409334 Cable socket, 5 pole, M12 1, straight, without connecting cable, assembly by customer 00419130 Measuring device holder for wall and 2" pipe 00597711 CD-setup program a 00522384 a The setup program can only be used for configuration in conjunction with these accessories.