Multi-Function Ergonomics, Ergonomics and Knobs Handles

Similar documents
Sectional Directional Control Valve RSQ 240

Sectional Directional Control Valve RS 220

2/2-Way Pressure Relief Valve CX DBV (Right-Angle Design)

3/2 Way Ball Valves KHB3K

E / HYDAC KineSys Electric cylinders (HEZ)

Inline filters NF NF 1350 NF 330 NF 750 NF 500 NF FILTER SPECIFICATIONS Nominal pressure

Change-Over Diesel PreCare HDPD up to 1800 l/h

Plastic Tank Systems Standard models

Safety Equipment for Hydraulic Accumulators

Diesel PreCare HDP up to 1800 l/h

Feed Pumps VP / VPB / VPBM

The specified data apply only if actuators/signal indicators are combined with contact blocks and lamp sockets within the same product range.

Change-Over Inline Filter AFLD to API 614

Monoblock Directional Control Valve RM 230

Capacitive Switches

Capacitive Switches

Dual Axis Hydraulic Joystick Series JH4

Change-Over Inline Filter RFLD Weld Version

SHAPELINE PRODUCT OVERVIEW.

Electrohydraulic Drive System EHC-A

Air Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11

3SE03 North American Limit Switches

Safety Equipment for Hydraulic Accumulators

Suction Filter SF/SFM/SFF and Suction Filter Elements S/S..

Air Cooler Mobile AC-LNH 8-14 with hydraulic motor

Plate Heat Exchangers

EN / Modern Duplex Filters for Large Engines

Air Cooler Mobile OK-ELD 0-6 with DC motor

HYDAC (Three-Phase Current) Compact Power Units CO1

G3 UNIVERSAL GRIP CONFIGURATION GUIDE

HYDAC DC Compact Power Units DC1

RAFIX 22 QR. General data. Content

Selector Valve RV 713

Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF

Backflushing Filter AutoFilt RF3

Ceiling Star Installation Instructions

Spearhead Excel 565, 605 & 645T

Change-Over Inline Filter RFLD Welded Version

Stellantriebe. Classic Line. Electrical Actuators

Metal Bellows Accumulators for Heavy Diesel Engines

LUMOTAST FK. General data. Content

Knob handles IP

Return Line Filter HF4R up to 450 l/min, up to 10 bar

Cut out PRODUCT CODE HANDLE BODY FINISH MATERIAL MODUL. 5 mm Double bit 8 mm Square 9 mm Triangular Button. Stainless steel dust cap (Keyed alike) 03

TWO POST 4 TONNE CLEAR FLOOR HOIST

Drawing A Crankcase, Cylinder

ASSEMBLY SPARE PARTS LIST

Preliminary. SS66/SS88 Split Shaft PTO Parts List and Service Manual

GEX16/18/20s. Electric Four-Wheel Forklifts 48V, AC Drive Super Elastic Tyres kg kg kg.

ACCESS SOLUTIONS NEW PRODUCTS BROCHURE.

Change-Over Pressure Filter DFDK

Direct solenoid and solenoid pilot operated valves

Inline Filter LPF D A Flange-Mounted up to 280 l/min, up to 25 bar

APPLICATION AND SWITCH ORDERING GUIDE

SIRIUS Innovations. Technical information for ring terminals SIRIUS. Answers for industry.

Asynchronous generators

Old documentation - Only for your information! Product is not available any more!

HYDAC Quality for Pall Housings: Ecomicron 2-fit.

PITNEY BOWES FLEXIBLE INK JET TRANSPORT 36 FIT BASE: FIT-36. Parts Manual. (BOM: FIT36rev1.0) FIT-36parts_rev0 1

Return Line Filter RFM with 4-Hole Mounting

Return Line Filter RFM with 4-Hole Mounting

Isolator Sandwich Plate

SECTION 7: PARTS LIST FOR MODEL 5KL

GTX16/18/20s. Electric Lift Trucks Superelastic Tires kg kg kg.

Conditioning Module Reservoir Extraction CM-RE

Thermal Overcurrent Circuit Breaker 3120-F...

TPV 1000 (Ex 6-18) Variable Displacement Closed Loop System Axial Piston Pump HY-TRANS THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 109 / 1008 / E

MC SERIES. Illuminated Control Units. Super LED or Incandescent Illumination Removable Contact Blocks

Direct solenoid and solenoid pilot operated valves

Return Line Filter RF

C & S 22 mm NON-ILLUMINATED PUSHBUTTONS METAL BEZEL

Drawing A Cylinder, Engine pan

GTX16/18/20s. Electric Lift Trucks Superelastic Tyres kg kg kg.

MM184 Rev. 12 (9 94)

Thermal Overcurrent Circuit Breaker 3120-F...

SC450 PARTS LIST. Advance models: (1)

Pressure Filter DF...K P, DF...M P, Flange Mounted

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 114 / 0814 / E

Electronic Service Manuals

PART LIST P T O P T O S E R I E S S E R I E S

MAINTENANCE AND PARTS MANUAL

Thermal Overcurrent Circuit Breaker 3120-F...

Flex Finger Tooling 100/125 Series

Connection Housings for Cartridge Valves

Return line and Suction Boost Filter RKM

Bell Housing Accessories

Sales: Technical: Fax:

Direct solenoid and solenoid pilot operated valves

S 370 MODULAR STACK LIGHTS FEATURES. Multifunctional Lamp. 1 lamp, 3 different kinds of lights. Steady, flashing and rotating.

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

MultiRheo Filter MRF 1/2/3/4/5/6/7

Safety Sensor CSS 180 Product Information

Direct solenoid and solenoid pilot operated valves

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min

Direct solenoid and solenoid pilot operated valves

Recommended spare parts and often used accessories

Thermal Overcurrent Circuit Breaker 3120-F...

Actuator LD3. Product Data Sheet Feature

Solenoid interlock AZM 200 The non-contact interlock.

31/05/2013P:\INVENTORY\SLOW\krone\Krone surplus parts31may12 31May13.xls

Transcription:

Multi-Function Ergonomics, Ergonomics and Knobs Handles Introduction The materials are chosen to be suitable for either internal or external use and are resistant to ultra-violet effects. They are also suitable for a wide range of other environmental conditions. The standard straight ergonomic handle is available with a range of switches and push buttons, while the MFE handle range is available with an extensive range of switches and push buttons to suit different operating and environmental conditions. The MFE handle range can be configured to suit either left hand or right hand operation. Different circuit arrangements can be accommodated within the handle and the wiring can be built into connectors to customer specifications. Benefits z Range of knobs for individual lever control z Range of straight levers, with and without switches, for dual axis controls z Extensive range of stylish multi functional lever options z Extensive range of electrical switch and button options z Adaptable to both Hydac and other manufacturers equipment z Circuits and connectors to customer requirements z Switch options allow left hand or right hand operation z Tolerant to many environmental conditions z High durability, low maintenance 1

K Series knobs KB Duroplast knob KB = Duroplast knob KC KD KK KL KP = Technopolymer knob = Duroplast knob with switch = Knob with rubber cap = Knob with len = Spherical knob KW = Knob with switch 6 45 8 Ø5 M10 S Series ergonomic SA = Handle without electric switch SD SS SX SY = Handle with electric switch = Handle with electric switch to close and safety button = Handle with electric switch to close KC Technopolymer knob 65 50 Ø45 Ø10 KP Spherical knob Ø45 42.5 = Handle with electric switch dual rocker type Ø12 KK Knob with rubber cap Ø60 18 6. M12 Ø2 KL Knob with len Ø2 25 42 Ø8 2

KD Duroplast knob with switch SA Without switch Ø52 Ø.5 20 15 M10 Ø1 Input voltage: IP64 1 A 0 V DC For installation dimension see knob KB Wiring diagram KW Duroplast knob with switch SX With one switch on the top Ø52 Ø.5 X 166 166 12 11 - + 12 11 20 M10 Ø1 X Input voltage: IP54 5 A 250 V AC 10 5 cycles For installation dimension see knob KK IP54 16 A Input voltage: 250 V DC - + - + Wiring diagram Wiring diagram

SS With one switch on the top with safety cage SD With one switch on the top and one switch on the side Ø52 Ø52 Ø.5 Ø.5 X X 166 12 11 166 12 54 D 11 20 M10 Ø1 20 M10 Ø1 Input voltage: IP54 16 A 250 V DC X IP54 16 A on X, 1 A on D Input voltage: 250 V DC on X, - + 0 V DC on D + - + - Wiring diagram Wiring diagram X D SY With one position on the top spring centered Ø52 Ø.5 A B 20 166 12 11 M10 Ø1 A B Input voltage: IP54 16 A 250 V DC - + - Wiring diagram 4

Model code MFE = Multifunction-Ergonomic MFE X XXXX XX X X X X XXX Push button/switch option A = Plastic push button with microswitches rated A at 0 V DC B = Sealed push button with microswitches rated A at 0 V DC C = Insulated push button with microswitches rated 0.4 A at 0 V DC E = Serviceable sealed push button with microswitches rated A at 0 V DC Push button/switch in position 1 6 Insert ID letter for each button/switchchosen on the following list and in progressive sequence from position 1 up to position 6: Note: Type C not available in pos. 1 and 4 X = no button switch B = blue G = green R = red Y = yellow W = white (available only for type C and E) L = signalling led Push button/switch in position 8 For each push button/switch, insert ID position numbers and colours (see 1 6 position) and omit ones that are not required (i.e. 8R10G = red push button/switch in position 8 and green push button/switch in position 10) Note: push button/switch in pos.1-14-15 are available only type C push button type A and B are not available in pos. 8 Safety trigger in position X = no safety trigger T = with standard safety trigger TCAP = with capacitive safety trigger Wiring termination 0 = flying leads 2 = with connector (maker and model number to be specified on order) Gaiter collar 0 = basic version without provision for protection boot R = with provision for round boot S = with provision for square boot Mounting adapter 0 = standard straight M10x1.5 1 = tilted 15 forward 2 = tilted 15 right (LH handle) = tilted 15 left (RH handle) 4 = combined tilted 15 forward and 10 right (LH handle) 5 = combined tilted 15 forward and 10 left (RH handle) 6 = with spherical joint, adjustable from 0 up to 20 in any direction Rocker switch option omit if not required 5

Pushbuttons type A Plastic push button IP6 A 0 V DC B Sealed push button IP6 A 0 V DC C Isolated push button IP6 0.4 A 0 V DC E Sealed serviceable push button IP6 A 0 V DC T Safety trigger IP6 A 0 V DC TCAP Capacitive safety trigger EMC tested IP54 2.6 A 10-0 V DC x 6

Rocker switch options S Type Waterproof Life: IP68 10 A (28 V DC) 5 x 10 4 cycles R Type Long life Life: IP6 0.25 A (28 V DC) Vertical mounted Horizontal mounted Two vertical mounted S1B: IP68 Position momentary S2B: IP68 position latched R1B: Long life position momentary R2B: long life position latched S1A: IP68 Position momentary S2A: IP68 position latched R1A: Long life position momentary R2A: long life position latched S4A: IP68 Position momentary S4B: IP68 position latched R4A: Long life position momentary R4B: Long life position latched Vertical mounted left offset Vertical mounted right offset S1C: IP68 Position momentary S2C: IP68 position latched R1C: Long life position momentary R2C: Long life position latched S1D: IP68 Position momentary S2D: IP68 position latched R1D: Long life position momentary R2D: Long life position latched

Other switch options D 4 Way On-Off Switch IP68 1 A (28 V DC) 10 5 cycles DLDRDB switches DLDR 2 switches top DLDB 2 switches left DRDB 2 switches right DL 1 switch left DR 1 switch right DB 1 switch center R Proportional analogue rocker Output signal: IP65 0.01 A 8-0 V DC 0.5-4.5 V DC with 2.5 V in neutral position 2 x 8

Other switch options RP Proportional roller Output signal: IP68 0.028 A (5 V DC max) 0.5-4.5 V DC with 2.5 V in neutral position 2 x RP One centered 2RP Two centered RPD One right offsey RPS One left offset

Compatibility table 1 14 2 1 4 5 6 11 8 12 15 16 10 Push Buttons On-Off Rocker Switch Push Buttons 4 Way Switch Positions Proportional Rocker Key Push Buttons On-Off Rocker Switch Push Buttons 4 Way Switch Positions Proportional Rocker 1 2 4 5 6 8 10 11 12 1 14 15 16 S(R)1B S(R)1A S(R)4A S(R)1C S(R)1D DLDRDB DLDR DLDB DRDB DL DR DB R RP 2RP RPS RPD S(R)2B S(R)2A S(R)4B S(R)2C S(R)2D 1 * 2 4 * 5 6 8 10 11 12 1 14 15 16 S(R)1B S(R)2B S(R)1A S(R)2A S(R)4A S(R)4B * * S(R)1C S(R)2C S(R)1D S(R)2D DLDRDB DLDR DLDB DRDB DL DR DB R * RP 2RP RPS RPD = available combination = not available * Available only Type A 10

Mounting adapters 0 Standard straight 1 Tilted 15 forward 2 Tilted 15 right hand 15 15 Tilted 15 left hand 4 Combined tilting right hand 5 Combined tilting left hand 6 With ball joint 18 182 18 18 Ø16 Ø20 Ø20 10 M10x1.5 1 10.5 M10x1.5 10.5 M10x1.5 15 11 11 Ø20 10.5 M10x1.5 10.5 M10x1.5 Ø20 11 11 20 20 182 182 0 10.5 M10x1.5 Ø20 10 M0x1 Ø6 11 11

Protective boots R Round protection boot Ø20 Ø22.5 Ø6 Ø6 Gaiter collar for standard straight mounting adaptor Gaiter collar for tilted mounting adaptor S Square protection boot Ø40 Ø40 6 2.4 6 2.4.5 86 86 2 2 Gaiter collar for standard straight mounting adaptor Gaiter collar for tilted mounting adaptor Note The information in this brochure relates to the operating conditions and applications described. For applications or operating conditions not described, please contact the relevant technical department. Subject to technical modifications. 12 Head Office HYDAC INTERNATIONAL GMBH Industriegebiet 6680 Sulzbach/Saar Germany Tel.: +4 68 50-01 Fax: +4 68 50-5 E-mail: mobilevalves@hydac.com Internet: www.hydac.com