FEATURES. a coil in horizontal position) Three speed PSC blower motor. Accessory Heater. Designed for 208/240 Volt. Single & Three phase models

Similar documents
MF Series SPECIFICATIONS MODULAR ELECTRIC FURNACE 2THRU5TONSAIRFLOW ACCESSORY 5 KW KW ELECTRIC HEAT

MF Product Specifications

MV Product Specifications

ARUF Series. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons. Contents. Product Features

ELECTRIC HEAT AIR HANDLERS

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT

ELITE SERIES R-410A Ready - Multi-Position

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS

ARUF PRODUCT SPECIFICATIONS AIR HANDLER 1½ TO 5 TONS MULTI-POSITION, THREE-SPEED WITH GALVANIZED CABINET

FORM NO. HSC-543 AIR HANDLERS

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION

PA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE

AIR HANDLERS AIR HANDLERS. RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant. Features

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHR18 THRU 60* WARRANTY

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION FEATURE

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

PAB SERIES 3thru6-1/3Ton. Belt Drive 10 SEER CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT /01

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425)

Ruud High Efficiency Air Handler

BCE5V PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS ACCESSORIES WARRANTY

Q5RD Series Single Packaged Heat Pump, Single Phase

FEM4X, FSM4X, FSU4X. Product Specifications

Typical Applications. Horizontal Installation

Rheem High Efficiency Air Handler

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

P3RC-12 SEER 2 Ton thru 4 Ton Units Cooling: 23,800 to 48,000 Btuh

Dimensions Filter Size in. (mm) lbs. (kg) FVM4X2400B 135 (61) FVM4X2400BT

CONVERTIBLE SINGLE PACKAGE HEAT PUMP

135 (61) FVM4X2400AT. (416 x 546) FVM4X3600A FVM4X3600AT FVM4X4800A FVM4X4800AT FVM4X6000A FVM4X6000AT 1400 (661) 1600 (755) 2000 (944)

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

FEM4P, FSM4P, FSU4P. Product Specifications

GQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY

EBP. Product Specifications. EBP Fan Coils 2 THRU 5 TONS SPLIT SYSTEM FEATURES. Model Number

Rheem High Efficiency Air Handler

Rheem Air Handlers. RHLP- Standard Efficiency X-13 (ECM) Motor

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

Q7RE Series Single Packaged Heat Pump, Single Phase

Multi-Position Air Handler. 1½ to 5 Tons. with Energy-Saving Motor

AIR HANDLERS RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT

ELITE Series R-410A - Upflow / Horizontal

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

AVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

GP5RD Series. Single Packaged Air Conditioner, Single Phase TECHNICAL SPECIFICATIONS

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

BCE5E PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS WARRANTY

BCE3 PRODUCT SPECIFICATIONS STANDARD AIR HANDLER APPLICATION INSTALLATION CABINET COMPONENTS ACCESSORIES WARRANTY

MERIT Series R-410A - Upflow / Horizontal - Variable Speed

PCB COMMERCIAL SERIES

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

GR4GA Series Single Packaged Gas/Electric Units

PHF SERIES. THREE PHASE 50 Hz OPERATION CONVERTIBLE SINGLE PACKAGE HEAT PUMP

BCE3V PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COMPONENTS ACCESSORIES WARRANTY

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

FEM, FSM, FSU. Product Specifications

CFM Range Tons x 21 1 / 8 x x 21 FVM*X4800A 48, FVM*X6000A 60, x 24 x x

ARUF Series Multi-Position

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

FEM, FSM, FSU. Product Specifications FAN COILS

PA55 10 SEER FEATURES 2 THRU 5 TON SINGLE PACKAGE AIR CONDITIONER

GR4GC Series Single Packaged Gas/Electric Units

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

N9MSB. PS 92 Product Specifications. 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL /2/17

Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL

GQ4SD Series. Single Packaged Heat Pump 13 SEER TECHNICAL SPECIFICATIONS

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

AIR HANDLERS UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT PRELIMINARY NOT FOR DISTRIBUTION

PHB SERIES 7-1/2 and 10 TON

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

HMG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler. 13 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)

Q7RE Series Single Packaged Heat Pump, Single Phase

ZHA/ZHB SERIES WARNING

AIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381)

1. Air Handler Features Page Physical data Page Available kits Page Model nomenclature Page 5

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

P5RF Series Single Packaged Air Conditioner Single Phase

HMG*T TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)

95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES

WFSR. Product Specifications 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT

AWUF Series. Wall-Mount Air Handler 1½- to 3-Tons

GQ4SD Series. Single Packaged Heat Pump 13 SEER TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

AIR HANDLERS AIR HANDLERS. UHKA- SERIES featuring R-22 Refrigerant UHKL- SERIES featuring Earth-Friendly R-410A Refrigerant.

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN

DF6SF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Cooling Capacity CFM in. w.c. (125 Pa)

P7RD-A Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

GMH95/GCH9 PRODUCT SPECIFICATIONS 95%/93% AFUE HEAT REPLACEMENT MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE

Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

GMS9/GCS9 SERIES 93% AFUE

Transcription:

ELECTRIC FURNACE 2 THRU 5 TONS SPLIT SYSTEM EF Series FEATURES Electric Furnace, Air Conditioning or Heat Pump ready Upflow or horizontal left or right airflow as shipped. (Horizontal Drain Pan Accessory required if used with a coil in horizontal position) Downflow applications require Subbase Accessory Prepainted galvanized steel cabinet Internally lined with R4.2, 1 Tuf--Skin II insulation Electronic control board with quick connect receptable for electric heat Direct drive slide-out blower assembly Three speed PSC blower motor Accepts EPA and EXA Series of A--coils Multiple condensate drain provisions, allow choice of location for primary and secondary connections Accepts accessory slip-in electric heaters Accepts accessory two stage outdoor thermostats Representative photo only, some models may vary in appearance. Accessory Heater UL listed for sale in U.S.A. and Canada Easy to install with simple plug in connection to Electric Furnace Designed for 208/240 Volt Single & Three phase models 5, 7.5 and 10 nominal KW models available with lug terminals 5, 7.5, 10, 15, 20, 25 and 30 nominal KW models available with Circuit Breakers Auto-reset high temperature limits Listed By Underwriters Laboratories 442 31 2201 03 June 2002

UNIT SPECIFICATIONS - ELECTRIC FURNACE Model Number EF08B1500A EF12F1900A EF16J2200A EF20N2600A Application Upflow / Horizontal / Downflow * Electrical Volts-Phase-Hz. 208 / 230-1 - 60 Data ** Minimum Circuit Ampacity 7.5 7.5 7.5 7.5 Time Delay Fuse (Amps) 15 Fuse or Breaker Size (Amps) 15 Blower Size DD10-7 DD10-8 DD10-9 DD10-9 Data Horsepower - Speed 1/3-3 1/2-3 1/2-3 3/4-3 Full Load / Lock Rotor Amps 2.2 / 4.1 4.0 / 6.8 4.0 / 6.8 6.0 / 13.2 Transformer 40 VA Washable Air Filter Size, I Thick (In.) (Field Supplied) 14-1 / 4 X20-1 / 4 17-3 / 4 X20-1 / 4 21-1 / 4 X20-1 / 4 24-3 / 4 X20-1 / 4 Disposable Air Filter Size, I Thick (In.) (Field Supplied) 14 X 20 18 X 20 20 X 20 25 X 20 Weight Shipping / Net (Lbs.) 54 / 50 54 / 50 75 / 70 85 / 80 * Kit required for Accessory Subbase ** Disregard if electric heat is added. Refer to Electric Heat table. 14-3 / 8 (EF08) 17-7 / 8 (EF12) 21-1 / 2 (EF16) 25-1 / 8 (EF20) 3/4 Low Voltage Alternate LineVoltage Line Voltage 45 (EF08-12) Drain Connections For Horizontal Main 3/4 Fpt Overflow 3/4 FPT Suction- Liquid 54 (EF16-20) CLEARANCES Main/Overflow Drains 3/4 FPT 21 1 / 2 NO HEATERS All Sides... 0 From Supply Duct... 0 Service From Front... 20 (Service for blower, filter if installed) 16-3 / 8 (EF08) 19-7 / 8 (EF12) 23-1 / 2 (EF16) 27-1 / 8 (EF20) Filter Door WITH HEATERS All Sides... 0 From First Three Feet of Supply Duct to Combustibles... 1 From Duct after Three Feet... 0 Service From Front... 20 (Service for blower, filter, heaters if installed)

Airflow Based on no coil, no filter, no electric heat. Deduct heater static shown in heater static table. Deduct filter static shown in filter static table. Deduct coil static, See Coil Specification Sheet. Deduct.10 for Horizontal Drain Pan Kit. Deduct.20 for Downflow Subbase Kit. EF08 EF16 LOW 230V 1053 1013 965 911 856 761 654 552 208V 863 827 788 725 641 568 492 381 MED 230V 1333 1281 1221 1150 1060 990 857 743 208V 1156 1115 1059 997 941 853 738 618 HIGH 230V 1553 1486 1411 1328 1227 1106 1032 865 208V 1394 1336 1272 1195 1096 1023 924 774 EF12 LOW 230V 1103 1092 1086 1060 1024 973 906 803 208V 903 893 877 858 830 781 728 642 MED 230V 1498 1473 1451 1409 1352 1277 1173 1044 208V 1246 1239 1222 1202 1160 1098 1014 906 HIGH 230V 1860 1815 1760 1685 1596 1491 1352 1178 208V 1602 1584 1553 1501 1432 1347 1241 1096 LOW 230V 1103 1088 1067 1040 994 921 849 749 208V 872 847 820 788 750 696 630 530 MED 230V 1500 1493 1470 1438 1383 1303 1143 993 208V 1229 1223 1198 1169 1123 1031 926 798 HIGH 230V 1912 1879 1830 1771 1684 1577 1429 1154 208V 1629 1609 1584 1545 1478 1393 1214 1058 EF20 LOW 230V 1673 1670 1669 1643 1587 1461 1298 1081 208V 1320 1306 1289 1237 1147 1006 810 576 MED 230V 2060 2030 1980 1912 1835 1723 1594 1444 208V 1676 1656 1613 1531 1381 1201 986 683 HIGH 230V 2554 2459 2352 2242 2116 1966 1809 1606 208V 2420 2334 2244 2137 2021 1875 1732 1558 FILTER STATIC PRESSURE DROP *WASHABLE DISPOSABLE CFM MODEL FILTER SIZE FILTER SIZE 600 800 1000 1200 1400 1600 1800 2000 EF08 14 1 / 4 X20 1 / 4 14 X 20 0 0.09 0.13 0.19 -- -- -- -- -- -- -- -- -- -- -- -- EF12 17 3 / 4 X20 1 / 4 18 X 20 -- -- -- -- -- -- -- -- 0.09 0.12 0.17 0.22 -- -- -- -- -- -- EF16 21 1 / 4 X20 1 / 4 20 X 20 -- -- -- -- -- -- -- -- -- -- -- -- -- -- 0.12 0.15 0.19 -- -- -- EF20 24 3 / 4 X20 1 / 4 25 X 20 -- -- -- -- -- -- -- -- -- -- -- -- -- -- 0.09 0.11 0.14 0.18 HEATER STATIC TABLE HEATER KW / STATIC DROP CFM 5 7.5 10 15 20 25 30 600 800 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000.06.06 DO NOT OPERATE IN THIS AREA CFM / KW LIMIT EXCEEDED Deduct heater static shown in heater static table. See Airflow next page. UNIT SPECIFICATIONS - No Heat Kit Overcurrent Supply Wire Supply Branch Protective 75 0 C. Copper Ground No Heat Supply Circuit Circuit Motor Total Circuit Device Max. Wire Model Volts Phase Hertz No. AMPS. AMPS. Ampacity (AMPS.) No. Size Length (Ft) No. Size AMF001NH 240 1 60 Single 6.0 6.0 7.5 15 2 14 104 1 14 208 1 60 Single 6.0 6.0 7.5 15 2 14 90 1 14

ELECTRICAL HEATER DATA TABLE: (Single Phase) ELECTRICAL HEATER DATA TABLE: (Three Phase) Overcurrent Supply Wire Nomil Supply Heater Maxi- Branch Protective 75 0 C. Copper Ground Heater Supply Heating Heat- KWPer Circuit KWPer Heater Motor Total Circuit Device Max. Wire Model Voltage BTUH KW Element No. Circuit AMPS. AMPS. AMP Ampacity (AMPS.) No. Size Length (F No. Siz AMFK05AH 240 16,832 4.8 4.8 Single 4.8 20.0 6.0 26.0 S 32.5 35 2 10 61) 1 10 208 12,287 3.6 3.6 Single 3.6 17.3 6.0 23.3 29.2 30 2 10 59 1 10 AMFK07AH 240 24573 7.2 3.6 Single 7.2 30.0 6.0 36.0 45.0 45 2 8 70 1 10 208 18430 5.4 2.7 Single 5.4 26.0 6.0 32.0 40.0 40 2 8 68 1 10 AMFK10AH 240 32,765 9.6 4.8 Single 9.6 40.0 6.0 46.0 57.5 60 2 6 85 1 10 208 24,574 7.2 3.6 Single 7.2 34.7 6.0 40.7 50.8 60 2 6 83 1 10 240 49,147 14.4 4.8 Single 14.4 60.0 6.0 66.0 82.5 90 2 4 94 1 8 AMFK14AH Mult. 1 9.6 40.0 6.0 46.0 57.5 60 2 6 50 1 10 AMFK15AH Mult. 2 4.8 20.0 0.0 20.0 25.0 25 2 12 1 10 208 36,860 10.8 3.6 Single 10.8 52.0 6.0 58.0 72.5 80 2 4 93 1 8 Mult. 1 7.2 34.7 6.0 40.7 50.8 60 2 6 50 1 10 Mult. 2 3.6 17.3 0.0 17.3 21.7 25 2 12 1 10 240 65,530 19.2 4.8 Single 19.2 80.0 6.0 86.0 107.5 110 2 2 115 1 6 Mult. 1 9.6 40.0 6.0 46.0 57.5 60 2 6 63 1 10 AMFK20AH Mult. 2 9.6 40.0 0.0 40.0 50.0 50 2 8 1 10 208 49,147 14.4 3.6 Single 14.4 69.3 6.0 75.3 94.2 100 2 3 90 1 8 Mult. 1 7.2 34.7 6.0 40.7 50.8 60 2 6 63 1 10 240 81912 24.0 4.8 Single 24.0 100.0 6.0 106.0 132.5 150 2 1/0 148 1 6 Mult. 1 9.6 40.0 6.0 46.0 57.5 60 2 6 50 1 10 Mult. 2 9.6 40.0 0.0 40.0 50.0 50 2 8 1 10 AMFK25AH Mult. 3 4.8 20.0 0.0 20.0 25.0 25 2 12 1 10 208 61,434 18.0 3.6 Single 18.0 75.1 6.0 81.1 101.4 110 2 2 106 1 6 Mult. 1 7.2 34.7 6.0 40.7 50.8 60 2 6 50 1 10 Mult. 3 3.6 17.3 0.0 17.3 21.7 25 2 12 1 10 240 98,294 28.8 4.8 Single 28.8 120.0 6.0 126.0 157.5 175 2 2/0 158 1 6 Mult. 1 9.6 40.0 6.0 46.0 57.5 60 2 6 63 1 10 Mult. 2 9.6 40.0 0.0 40.0 50.0 50 2 8 1 10 AMFK30AH Mult. 3 9.6 40.0 0.0 40.0 50.0 50 2 8 1 10 208 73,721 21.6 3.6 Single 21.6 90.1 6.0 96.1 120.2 125 2 1 112 1 6 Mult. 1 7.2 34.7 6.0 40.7 50.8 60 2 6 63 1 10 Mult. 3 7.2 34.7 0.0 34.7 43.3 45 2 8 1 10 Overcurrent Supply Wire Nomil Supply Heater Maxi- Branch Protective 75 0 C. Copper Ground Heater Supply Heating Heat- KWPer Circuit KWPer Heater Motor Total Circuit Device Max. Wire Model Voltage BTUH KW Element No. Circuit AMPS. AMPS. AMP Ampacity (AMPS.) No. Size Length (F No. Siz AMFH10AH 240 32,765 9.6 3.2 Single 9.6 23.1 6.0 29.1 S 36.4 40 3 8 100 ) 1 10 208 24,574 7.2 2.4 Single 7.2 20.0 6.0 26.0 32.5 35 3 10 61 1 10 240 49,147 14.4 4.8 Single 14.4 34.6 6.0 40.6 50.8 60 3 6 111 1 10 AMFK15AH 208 36,860 10.8 3.6 Single 10.8 30.0 6.0 36.0 45.0 50 3 8 70 1 10 240 65,530 19.2 3.2 Single 19.2 46.2 6.0 52.2 65.2 70 3 4 138 1 8 Mult. 1 9.6 23.1 6.0 29.1 36.4 40 3 8 79 1 10 AMFH20AH Mult. 2 9.6 23.1 0.0 23.1 28.9 30 3 10 1 10 208 49,147 14.4 2.4 Single 14.4 40.0 6.0 46.0 57.5 60 3 6 85 1 10 Mult. 1 7.2 17.3 6.0 23.3 29.2 30 3 10 57 1 10 Mult. 2 7.2 17.3 0.0 17.3 21.7 25 3 12 1 10 240 81912 24.0 4.0 Single 24.0 57.7 6.0 63.7 79.7 80 3 4 113 1 8 Mult. 1 12.0 28.9 6.0 34.9 43.6 45 3 8 83 1 10 AMFH25AH Mult. 2 12.0 28.9 0.0 28.9 36.1 40 3 8 1 10 208 61,434 18.0 3.0 Single 18.0 50.0 6.0 56.0 70.0 80 3 4 111 1 8 Mult. 1 9.0 21.7 6.0 27.7 34.6 35 3 10 57 1 10 Mult. 2 9.0 21.7 0.0 21.7 27.1 30 3 10 1 10 240 98,294 28.8 4.8 Single 28.8 69.3 6.0 75.3 94.1 100 3 3 120 1 8 Mult. 1 14.4 34.6 6.0 40.6 50.8 60 3 6 84 1 10 AMFH30AH Mult. 2 14.4 34.6 0.0 34.6 43.3 45 3 8 1 10 208 73,721 21.6 3.6 Single 21.6 60.0 6.0 66.0 82.6 90 3 4 94 1 8 Mult. 1 10.8 26.0 6.0 32.0 40.0 45 3 8 61 1 10 Mult. 2 10.8 26.0 0.0 26.0 32.5 35 3 10 1 10

HEATER STAGING HEATER MODEL VOLTAGE TOTAL HEAT 1st STAGE (W1) 2nd STAGE (W2) 208V 240V 208V 240V 208V 240V AMFK05AH 208--240/1/60 3.6 4.8 3.6 4.8 -- -- AMFK07AH 208--240/1/60 5.4 7.2 2.7 3.6 2.7 3.6 AMFK10AH 208--240/1/60 7.2 9.6 3.6 4.8 3.6 4.8 AMFK14AH AMFK15AH 208--240/1/60 10.8 14.4 7.2 9.6 3.6 4.8 AMFK20AH 208--240/1/60 14.4 19.2 7.2 9.6 7.2 9.6 AMFK25AH 208--240/1/60 18.0 24.0 7.2 9.6 10.8 14.4 AMFK30AH 208--240/1/60 21.6 28.8 7.2 9.6 14.4 19.2 AMFH10AH 208--240/3/60 7.2 9.6 7.2 9.6 -- -- AMFH15AH 208--240/3/60 10.8 14.4 10.8 14.4 -- -- AMFH20AH 208--240/3/60 14.4 19.2 7.2 9.6 7.2 9.6 AMFH25AH 208--240/3/60 18.0 24.0 9.0 12.0 9.0 12.0 AMFH30AH 208--240/3/60 21.6 28.8 10.8 14.4 10.8 14.4 ACCESSORIES Model Description Use With AMF001NHA No Heat Kit EF08-20 AMFK05AHA* AMFK05AHB 5 KW Single Phase EF08-20 AMFK07AHA* AMFK07AHB 7 1/2 KW Single Phase EF08-20 AMFK10AHA* AMFK10AHB 10 KW Single Phase EF08-20 AMFK14AHB 15 KW Single Phase EF08-20 AMFK20AHB 20 KW Single Phase EF12-20 AMFK25AHB 25 KW Single Phase EF16-20 AMFK30AHB 30 KW Single Phase EF16-20 AMFK20SPA Single Point Wiring Kit 15-20 KW AMFK30SPA Single Point Wiring Kit 25-30 KW AMFH10AHB 10 KW Three Phase EF12-20 AMFH15AHB 15 KW Three Phase EF12-20 AMFH20AHB 20 KW Three Phase EF16-20 AMFH25AHB 25 KW Three Phase EF16-20 AMFH30AHB 30 KW Three Phase EF16-20 *AHA Models are Non -Breaker Models MODEL NUMBER IDENTIFICATION GUIDE EF 12 F19 00 A PRODUCT FAMILY EF = ELECTRIC FURNACE NOMINAL AIRFLOW 08 = 800 CFM 12 = 1200 CFM 16 = 1600 CFM 20 = 2000 CFM SALES CODE FIELD INSTALLED HEATERS MATCHING COIL (NOMINAL WIDTH) ACCESSORIES Model Description Use With AMF002OTA 2 Stage Outdoor Thermostat 7.5 KW & Above AMF001DPA Horizontal Drain Pan Kit EF08-12 AMF002DPA Horizontal Drain Pan Kit EF16-20 AMF015DFA Downflow Kit (Subbase) EF08 AMF019DFA Downflow Kit (Subbase) EF12 AMF022DFA Downflow Kit (Subbase) EF16 AMF026DFA Downflow Kit (Subbase) EF20 AMF015WFA Washable Filter EF08 AMF019WFA Washable Filter EF12 AMF022WFA Washable Filter EF16 AMF026WFA Washable Filter EF20 * Obtain thru Service Parts ACCEPTABLE LOOSE COILS FOR ELECTRIC FURNACES EF08 EPA24B15A EXA24B15A EPA30B15A EPA36B15A EF12 EF16 EF20 EPA30F19A EXA24F19A EPA36J22A EXA36J22A EPA48N26A EXA48N26A EPA36F19A EXA36F19A EPA42J22A EXA42J22A EPA60N26A EXA60N26A EPA42F19A EPA48J22A Shaded coils Have Not been tested with electric furnace See Coil Specification Sheet for most current information. EPA48F19A EPA60J22A ACCESSORIES NUMBER IDENTIFICATION GUIDE A M F 001 DP A PRODUCT GROUP SALES CODE A = Accessories PRODUCT IDENTIFIER PRODUCT TYPE PRODUCT IDENTIFIER NUMBER C = Cooling H = Heating X = Special M = Multi Use (Heating and / or Cooling) SERIES ACCESSORY PRODUCT IDENTIFIER ASSIGNMENT AH -- Auxiliary Heater DP -- Drain Pan Kit OT -- Outdoor Thermostat DF -- Downflow Kit WF -- Washable Filter NH -- No Heat Kit SP -- Single Point Wiring Kit TK -- Thermostatic Expansion Valve