lubricants analysis. complete solutions for your lab. Lubricants Analysis

Similar documents
Analysis of Wear Metals Using the Teledyne Leeman Labs Prodigy Plus ICP-OES

MiniLab EL Series for High Performance Engine Development and Maintenance

Analysis of Petroleum Samples Using the Teledyne Leeman Labs

Advanced Petrochemical Applications With ICP-OES. Tina Harville, Ph.D. Application Engineer

MiniLab EL Series for High Performance Engine Development and Maintenance

Refinery and Natural Gas Analysis

The Analysis of Biodiesel for Inorganic Contaminants, including Sulfur, by ICP-OES

VHG Labs, Inc. Standards and Supplies for Spectrochemical Oil Analysis

Analysis of biodiesel oil (as per ASTM D6751 & EN 14214) using the Agilent 5100 SVDV ICP-OES

TSHR 6000 series TN/TS/TX analyzer

TSHR 7000 series TN-TS-TX analyzer

White Paper. Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Introduction. Background Information

breakthrough versatility

Application for Energy and Fuels

Low cost EDXRF elemental analyzer

Certificate of Accreditation

Joint Oil Analysis Program Spectrometer Standards SCP Science (Conostan) Qualification Report For D19-0, D3-100, and D12-XXX Series Standards

Biodiesel Analysis Utilizing Mini-Scan - Handheld Analyzer V.C. Gordon PhD, Bonanza Labs

224 Sulfur Standards 224 Biodiesel 225 Crude Oil 225 Diesel 225 Isooctane 226 Mineral Oil 226 Residual Oil SCP SCIENCE

LIABLE RESULTS AND RELIABLE RESULTS AND EXCEPTIONAL REPRODUCIBILITY

INTERPRETATION OF USED COOLANT ANALYSIS

Joint Oil Analysis Program Spectrometer Standards VHG Labs Inc. Qualification Report For D19-0, D3-100 and D12-XXX Series Standards

MONITORING SOLUTION FOR MARINE MAIN ENGINE CYLINDERS PROTECTION

Determining the Ethanol Content of Denatured Fuel Ethanol Using Near Infrared. Gulf Coast Conference Patrick Ritz PAC LP

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

Determination of Phenolic Antioxidant DBPC and DBP Levels in Electrical Insulating Oil

High-throughput protein aggregate analysis of monoclonal antibodies using a novel dual-channel UHPLC instrument

High-Performing Restek PAL SPME Fibers

MB3600-CH30 Laboratory FT-NIR analyzer for biodiesel applications Suitable for production optimization and product quality assessment

Free and Total Glycerol in B100 Biodiesel by Gas Chromatography According to Methods EN and ASTM D6584

UIN B. Diesel Engine E141. Unit No. Unit: Make Model Serial No.

Elemental Analysis Advanced

Report On Sequence IVB Evaluation Version. Conducted For. NR = Non-reference oil test RO = Reference oil test

MB3600-HP10 Laboratory FT-NIR analyzer for hydrocarbon applications Pre-calibrated for blended gasoline, diesel, reformate and naphtha

UL ALTERNATIVE FUELS & STANDARDS UPDATE

Application for Energy and Fuels

Oxidation Loss of additive effectiveness Dispersancy, Corrosion, Wear Permanent viscosity drop in multi - grade oils

Model 8610C Gas Chromatograph. GC Chassis Types ECD PID FID / DELCD FPD. Mounts up to Six Detectors and Five Injectors

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Group-Type Analysis (PiPNA) in Diesel and Jet Fuel by Flow Modulated GCxGC FID.

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph

Diesel Power. Advanced synthetic technology to protect today s most demanding diesels. SYNTHETIC DIESEL OILS. FuEL.

Detection of Volatile Organic Compounds in Gasoline and Diesel Using the znose Edward J. Staples, Electronic Sensor Technology

Simulated Distillation Analyzers, Software, Standards, Consumables, Training

MB3000. Versatile FT-IR analyzer designed for your industry The most reliable FT-IR, the lowest cost of ownership.

Why we need new Total Nitrogen parameter and methods for CWA reporting. William Lipps Chief Science Officer, Eurofins Eaton Analytical August 2018

CALIBRATION AND VERIFICATION STANDARDS. The benchmark for accurate measurements. Cerium Standards Sulfur-in-Oil Standards Viscosity Standards NEW

Determination of Free and Total Glycerin in Pure Biodiesel (B100) by GC in Compliance with EN 14105

Elemental Analysis of Biofuels with SPECTRO XRF and ICP Spectrometers

Mack T-11 D EGR Engine Oil Test. Report Packet Version No. Conducted For

MESA-7220 Measurement of Sulfur, Chlorine and other elements in Petroleum Products Using Mono-chromatic, Polarized EDXRF Analysis

Bright prospects Solvents for spectroscopy Uvasol

MESA-7220 Multi-Element Analyzer Using EDXRF Technology

ASTM D Standard Specification for Biodiesel Fuel (B 100) Blend Stock for Distillate Fuels

Q200. Aquamax FlashPoint. Q5800 MiniLab 53 MiniLab 153 MicroLab Q1000. Q100 Spectroil M. Q300/310 Q3000 Pat 940 Density 5

Ed Benelli. California Department of Toxic Substances Control. Office of Pollution Prevention and Green Technology

Over-the-Road Trucks SYNTHETIC MOTOR OILS. FuEL. FLuIdS

Application Note. Abstract. Authors. Environmental Analysis

Agilent 7693A Automated Liquid Sampler

Shell IMAA Workshop Making Sense of Oil Analysis

Monitor Chlorine in Crude at Sub-ppm Levels

X-ray Analysis in Petrochemical and Polymer Industries: Challenges and Solutions

Sulfur in Oil Analyzer

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

Water analysis, QC and more:

CALIBRATION AND VERIFICATION STANDARDS

ABB MEASUREMENT & ANALYTICS. Predictive Emission Monitoring Systems The new approach for monitoring emissions from industry

Fleet Solutions for Lubricant & Fluid Analysis

Calibration & Verification Standards

Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel

Prodigy ICP Application Note: # 1039

Measurement made easy. Predictive Emission Monitoring Systems The new approach for monitoring emissions from industry

The Analysis of Biodiesel for Trace Metals and the Development of Certified Biodiesel Standards

Analysis of Sulfur and Trace Element Content in FAME

LISTEN TO THE LIFEBLOOD OF YOUR MACHINE

Set Your Sights on Superior Performance

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS

Certificate of Accreditation

Set Your Sights on Superior Performance

Agilent 7693A Automated Liquid Sampler

Fast Simulated Distillation Based on Agilent 6890N Gas Chromatograph Application

DELIVERING MAXIMUM ENGINE PROTECTION

Thermo Scientific TITAN 4000 Total Nitrogen/Sulfur/ Chlorine Analyzer

Over-the-Road Trucks. FuEL FLuIdS SYNTHETIC MOTOR OILS

Technical Procedure for Gas Chromatography-Mass Spectrometry (GC-MS)

[ APPLICATION NOTE ] INTRODUCTION APPLICATION BENEFITS WATERS SOLUTIONS KEYWORDS

SCOPE OF ACCREDITATION TO ISO/IEC 17043:2010. ASTM INTERNATIONAL 100 Barr Harbor Drive West Conshohocken, PA Amy Meacock

Ultra Clean Gas Filters Reference Guide ULTRA CLEAN GAS FILTERS

Machine and Lubricant Condition Monitoring for Extended Equipment Lifetimes and Predictive Maintenance at Power Plants Abstract 1.

High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System

Automated Liquid Handling Station

ERAVAP NEW! VAPOR PRESSURE TESTING AT ITS BEST. One Vapor Pressure Tester for All Applications:

Phase Technology CPA-70Xi Cloud Point Analyzer

Going Green: The Analysis of BioFuels

Fundamentals of Oil Analysis

3/15/2017. Oil Analysis: When the Oil Speaks, You Should Listen! Oil Analysis. Common Wear Metals Found in Oil. Common Wear Metals Found in Oil

Dual Channel Simulated Distillation of Carbon and Sulfur with the Agilent 7890A GC and 355 Sulfur Chemiluminescence Detector

CALIBRATION AND VERIFICATION STANDARDS

Transcription:

Lubricants Analysis lubricants analysis. complete solutions for your lab.

PerkinElmer capabilities for lubricants analysis. The analysis of lubricants for conformity and process control has always been important to manufacturers and users in providing a high-quality lubricant. Once the lubricant is in the equipment, degradation and contamination become critical measurements. The ability to measure a wide range of analytes cost-effectively can mean the avoidance of damaged equipment or changing the lubricant more frequently than necessary. The level of machine repair and proper lubricant renewal intervals can be precisely evaluated with measurements of additives and wear metals, contaminants and other oil components over the course of use. Machine life can be extended and lubricant costs reduced by proper testing. PerkinElmer offers complete analytical solutions compliant with Caterpillar S O S SM, military JOAP and ASTM methods to facilitate measurements in new and used lubricants. Highly automated, these solutions provide cost-effective analyses with rapid turnaround time to maximize the impact of monitoring trends for any selected machine. Metals in oil The PerkinElmer Optima Series of ICP-OES coupled with two popular offline automated oil dilutors (Figure 1) is the gold standard for the measurement of additives and wear metals in oil. Typical analytes measured using the routine oil method are shown in Table 1 and reflect the different diagnostic capabilities of the various elements for additive depletion, wear indication and contamination. Figure 1. The Optima 8300DV, with the Janus Oil Workstation (l.) and the CETAC APS 1650 (r.), offers the performance required to maximize productivity. 2

Table 1. Routine Oil Analysis Metals. Element Lubricant Role Typical Concentration Ranges* (ppm) Ba additive 1 to 5000 Ca additive 1 to 10,000 Mg additive 1 to 2000 P additive 1 to 2000 S additive 1 to 5000 Zn additive 1 to 2000 B contaminant 1 to 100 K contaminant 1 to 500 Na contaminant 1 to 500 Si contaminant 1 to 500 Ag wear metal 1 to 500 Table 1. Routine Oil Analysis Metals, continued. Element Lubricant Role Typical Concentration Ranges* (ppm) Al wear metal 1 to 500 Cr wear metal 1 to 500 Cu wear metal 1 to 500 Fe wear metal 1 to 2000 Mn wear metal 1 to 1000 Mo wear metal 1 to 500 Ni wear metal 1 to 500 Pb wear metal 1 to 500 Sn wear metal 1 to 500 Ti wear metal 1 to 500 V wear metal 1 to 500 * Higher and lower concentration ranges can be analyzed with appropriate wavelength and standard selection. Both the PerkinElmer Janus Oil Workstation and the CETAC APS 1650 are proven systems for oil dilution in a wide range of oil products. The Janus system is for high-volume labs that want high throughput with minimal waste. The dilutor uses multiple syringes with disposable tips to dilute up to 300 samples per hour with no solvent rinsing. The CETAC APS 1650 is for small to medium labs using a single syringe with a sample probe. It dilutes a sample about every 40 seconds and uses typically under 10 ml of solvent rinsing between samples. Both systems come with liquid level sensing of the oil in each container and can use a variety of racks for the oil and the autosampler. The same computer used to control the Optima ICP-OES system can be used with the oil dilutors. The dilutors automatically create the WinLab32 sample information file (SIF) and place it in the proper location for Optima access. The Optima ICP-OES can measure a sample every 20 to 35 seconds (depending upon accessories), including rinsing and two replicate sample readings. The ICP stability is critical over the course of an 8-10 hour analysis. This can be monitored in real-time through QC samples, reducing the need for recalibration and keeping productivity high. Figure 2 shows excellent recovery of a wide range of analytes in a QC sample run as part of a batch of used oil samples. 70 65 60 55 50 45 40 35 30 50 ppm QC Standard Collected over 8 hours of operation Ag 328.068 Al 394.401 B 249.677 Ba 233.527 Cd 228.802 Cr 205.560 Cu 324.752 Fe 259.939 K 766.490 Mg 279.077 Mn 257.610 Mo 203.845 Na 588.995 Ni 231.604 Pb 220.353 Si 288.158 Sn 189.927 Ti 334.940 V 290.880 Figure 2. Optima 7300 V with the CETAC ASXpress Sampling Valve. www.perkinelmer.com/lubricants 3

Table 2. Typical Infrared Measurements. Parameter Spectral Measurement Regions (cm -1 ) Units Soot 3800 and 1980 Abs/cm FPO Figure 3. The Frontier OilExpress provides complementary measurement of oil contaminants, oxidation and nitration products. Modern analysis of non-metal contaminants and breakdown products Classic FT-IR analysis becomes more efficient FT-IR spectroscopic analysis has been used for many years as a screening test for contaminants and breakdown products in used oils. Advances in technology and software have made the technique highly reproducible, yielding a rapid pass/fail measurement whether in a laboratory or at a remote location. The Frontier OilExpress combines efficient automated liquid handling with FT-IR spectroscopy to provide complementary measurement of oil contaminants, oxidation and nitration products. The Spectrum Two Used Oil Analyzer combines small robust size with battery operation to add portability for taking the instrument to remote locations. Yet it will produce identical data with the lab-based OilExpress. Table 2 shows a list of the parameters routinely measured with this technology and the spectral region monitored. Both the OilExpress and Spectrum Two conform to all ASTM FT-IR methodologies for oils such as ASTM E2412, D7418, D7414, D7415, D7412 and D7674. Hydroxy (water and glycol) 3650-3150 Abs/cm, % water Glycol (mineral oils) 1140-1000 % Oxidation (mineral oils) 1720 Abs/cm NOx/Carboxylate (mineral oils) 1650-1538 Abs/cm NOx 1630 Abs/cm Oxidation/Sulfate 1150 Abs/cm Antiwear Loss (mineral oils) 700-640 Negative Abs/cm Antiwear Loss (synthetic oils) 1000-930 Negative Abs/cm Sulfate 640-590 Abs/cm Fuel Contamination (diesel) 820-800 Abs/cm Fuel Contamination (gasoline) 780-760 Abs/cm Ester Breakdown (synthetic oils) 3720-3590 Abs/cm 4

The Frontier OilExpress takes less than 70 seconds per sample to acquire data and rinse the system, providing twice the throughput of other systems. In addition, less than half the solvent is needed for rinsing when compared to current competitive systems. In spite of the small solvent volume used for rinsing, the carryover is less than 0.1%. Smaller samples are used for measurement, reducing waste and associated disposal costs by half. The system is automated and designed to run samples over a wide range of viscosities (4-700 cst). The zinc-selenide window transmission cell is not degraded by water, a possible lubricant contaminant, minimizing instrument maintenance costs. Figure 4 shows spectra identifying soot and several oil breakdown products. Spectrum Two from PerkinElmer offers trouble-free analysis of in-service lubricants with a manually operated instrument. With an intuitive touch screen interface and a dedicated in-service lubricants applications solution, even inexperienced IR-users can generate clear, high quality results. The compact design provides high-quality and reproducible data both in the laboratory and in harsher environments, even when remote from the main analytical lab. Compact, robust and completely transportable, it allows samples to be run in a central laboratory or in remote locations with no compromise in performance. Results are ready in minutes and meet the same quality standards expected from a full-service laboratory. For areas where a main power supply is not available or is intermittent, the Spectrum Two battery and 12V adaptor supply options ensure that the Spectrum Two will not let you down. Spectrum Two s flow cell can be cleaned using accessible solvents such as kerosene, a practical solution for on-site sampling. TBN increases FT-IR use The total base number (TBN) is a measure of the lubricant base content that can be used to neutralize acids introduced as a result of contamination or component degradation. The base capability is generally provided by a soap additive. Frontier OilExpress coupled with Quant+ software offers an automated and clean alternative as a quick screening tool to ASTM method D2896-01, Titration with Potentiometric Perchloric Acid, to determine the base content. The analysis time is improved by more than three times and the risk of handling and disposal of hazardous components is greatly minimized as you only titrate samples of concern. Figure 4. Spectra of oils obtained using the E2412 (JOAP) method. www.perkinelmer.com/lubricants 5

PerkinElmer offers a complete family of gas chromatography products that can carry out these determinations and are optimized for performance and reliability. The TurboMatrix automated headspace sample handling accessory provides integrated, easy sampling options (Figure 5). ASTM methods generally used for new and used lubricants are shown in Table 3. Figure 5. Clarus GC with liquid and headspace autosamplers for simultaneous determination of fuel dilution and glycol contamination. Gas chromatography Gas chromatography (GC) is a key analytical technique for lubricant analysis. Many analyses, done by simpler techniques in the past, benefit by the added information provided by the more sophisticated GC technique coupled with a variety of detectors. In many cases, the additional information can be generated faster and is more specific. For example, the presence of fuel (whether it is from gasoline, diesel and/or biodiesel) diluent in oil is evidence of mechanical failure. Physical tests, such as specific gravity or viscosity routinely employed in the evaluation of used crankcase oils, might indicate such a condition. However, only gas chromatography can provide a useful quantitative measure of the level of dilution, allowing more precise scheduling of maintenance, thus reducing cost. Although well-proven, many of the ASTM methods were originally developed many years ago and, since then, the needs of the industry for throughput and more detailed information have increased. Newer developments allow the combination of methods D3524 and D3525 for the determination of fuels in used engine oil to provide increased sample throughput in a more cost-effective method. Figure 6 shows the chromatogram of an oil standard and sample with fuel diluent with a run time improved by more than 10 times over the original method. Table 3. ASTM GC Oil Methods. ASTM Number D2887 D3524 D3525 D4291 Title Simulated Distillation for Boiling Point Distribution Diesel Fuel Diluent in Used Diesel Engine Oils by GC Gasoline Diluent in Used Engine Oils by GC Trace Ethylene Glycol in Used Oils by GC Gasoline (2% Standard) Biodiesel (5% Standard) Diesel (5% Standard) Diesel & Biodiesel Mix Figure 6: Typical chromatography for different fuels. 6

Table 4 shows a comparison of fuel diluents from this new version of the method compared with the original version, showing excellent agreement for a single injection. Precision studies show 3% RSD is typical at these concentration levels. Ethylene glycol analysis in used lubricants is a challenging analysis because of the low molecular weight, low volatility, and high polarity of the analyte combined with the high molecular weights of the oil. In order to overcome this challenge, a simple derivatization will improve the glycol volatility. This derivatization can be performed in a headspace vial and the sample extracted automatically from the vial for GC introduction. Gas chromatography, combined with automated headspace sampling, can help provide a cleaner sample preparation, providing reduced system maintenance. PerkinElmer will continue to work closely with customers and consensus-standards groups to improve existing methods and offer technology for new methods. Both the fuel and glycol contamination methods are currently being reviewed at ASTM to become standard methods. Table 4. Comparison of Fuel Diluent Results Between New Version and Original Version of the Method. Sample Fuel Content (%) Fuel Content (%) This Method Reference Method A 1.77 2.41 B 2.33 2.94 C 2.31 2.21 D 4.60 4.45 E 2.96 3.16 F 4.16 5.25 G 2.19 2.49 H 1.37 1.16 I 1.31 1.28 Data handling Trend analysis requires data to be collected frequently, processed and archived reliably. The individual instrument systems provide flexible data processing and reporting. Figure 7 shows a trend analysis for soot using the Frontier OilExpress native software. Many labs are moving to laboratory information management systems (LIMS) to manage the data from several techniques. This data moves seamlessly to multiple other business systems for storage or review. Connecting PerkinElmer instruments to an existing or new LIMS system is straightforward and can be easily accomplished. For a full system, PerkinElmer offers the scalable LABWORKS LIMS system that can evolve as your needs change. The unique ability to build the database and learn the system in a virtual environment before installation makes the transition seamless. Figure 7. Frontier OilExpress software showing database and trend for soot in oil. www.perkinelmer.com/lubricants 7

PerkinElmer, Inc. Dependable, worry-free technology Working with a technology leader brings several benefits. In addition to the existing instruments and applications, you can expect more. Actively pursuing new developments and applications, PerkinElmer is on the forefront of change. For example, some laboratories are now incorporating coolant analysis into their capabilities as a result of new developments. We have demonstrated compliance of Optima ICP-OES technology with ASTM D6130 for the measurement of various elements in new and used coolants. The ability to use the same instrument both for lubricants and coolant analysis minimizes the laboratory s investment and maximizes the laboratory s business flexibility. We will be there to inform you about new options as they develop. New methods are always being refined and we work with consensus groups, such as ASTM, on ICP-OES, FT-IR, GC, UV/Vis, LIMS and a variety of techniques to ensure that new methods are developed representing all perspectives. One Source provides one source to ensure peak performance in your lab With over 60 years of experience, and as world leader in analytical instrumentation, PerkinElmer is the right partner for the lubricants industry. In concert with global distribution of instruments, turnkey systems and consumables, we provide factory-trained global service and support. Our comprehensive worldwide service capability lets you take care of business and set your sights on what matters most results. With our multi-vendor services, One Source, our consolidated instrument support, you have a provider to optimize your lab operations. Over 1500 PerkinElmer professionals serve more than 125 countries worldwide. One Source is your source for instrument care and repair, validation services, software and hardware upgrades, relocation, training, education and more. Whatever you re looking for, we ve got it PerkinElmer is a leading provider of scientific instruments, consumables and services to the petrochemical, pharmaceutical, biomedical, environmental testing and general industrial markets, delivering integrated solutions, from sample handling and analysis to communication of test results. For lubricants analysis, we have the knowledge, products and comprehensive support you need. For more information on lubricants analysis, visit www.perkinelmer.com/lubricants PerkinElmer, Inc. 940 Winter Street Waltham, MA 02451 USA P: (800) 762-4000 or (+1) 203-925-4602 www.perkinelmer.com For a complete listing of our global offices, visit www.perkinelmer.com/contactus Copyright 2011, PerkinElmer, Inc. All rights reserved. PerkinElmer is a registered trademark of PerkinElmer, Inc. All other trademarks are the property of their respective owners. 006812B_01 Printed in USA