Supplemental Installation Instructions -- August 2016

Similar documents
Supplemental Installation Instructions -- August 2016

Electrical Data Supplement

Electrical Data Supplement

Electrical Data Supplement

Electrical Data Supplement

Owner s Information Manual

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS TABLE OF CONTENTS

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

CRECOMZR054B00 CRECOMZR055B00. VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS WARNING TABLE OF CONTENTS

Installation Instructions

Supplement Installation Instructions

Installation Instructions

ENERGY RECOVERY SYSTEM 60 HZ

Installation Instructions

Installation Instructions

3900 Dr. Greaves Rd. Kansas City, MO (816) FAX (816)

Installation Instructions

Advanced Product Data

Installation Instructions

Factory Option Codes L M E S P R D V F F H E

Installation Instructions

Installation and Start Up Instructions

Installation Instructions DNECOMZR020A02, DNECOMZR021A03 (For 3 to 12.5 Ton Units) and DNECOMZR062A00 (For RHS 12.5 Ton Heat Pump Units)

INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS. Part Number: P DM

Product Data Supplement

Installation Instructions

SYST0101ZP Ion Damper Control Installation and Start---Up Instructions

Installation Instructions

Installation Instructions

Installation Instructions

SERVICE INSTRUCTIONS

INSTALLATION INSTRUCTIONS

IMPORTANT ATTENTION INSTALLERS:

Package Unit Modulating Economizer Installation Instructions

Installation Instructions

REFRIGERATION COOLERS

Installation Instructions

50PG Ultra High Efficiency Single Package Electric Cooling with Optional Electric Heat Commercial Rooftop Units with PURON

Installation, Start-Up and Service Instructions

INSTALLATION INSTRUCTIONS

TECHNICAL SUPPORT MANUAL Coils for Manufactured Housing EMA2X, EMA4X

Model 436 V-Head Pipe Stand

INSTALLATION, START-UP AND SERVICE INSTRUCTIONS

LIGHT COMMERCIAL - 3 HP ECM MOTOR / CONTROLLER HIGH STATIC DRIVE KITS

AHKD SERIES ELECTRIC RESISTANCE HEAT KITS INSTALLATION & OPERATING INSTRUCTIONS

Installation and Start-Up Instructions

READ AND SAVE THESE INSTRUCTIONS. ComfortBreeze UV360-1 SYSTEM 24V Ultra-Violet Air Cleaner. Trion

TECHNICAL SUPPORT MANUAL WT A Coils for Replacement Service EXA, EPA

Installation Instructions

Auto-Flo Air-Assist Automatic Dispensing Valve

Installation Manual. English. French

TECHNICAL SUPPORT MANUAL Split System Heat Pump H2H3, 3 Phase

Installation, Start-Up and Service Instructions

TECHNICAL SUPPORT MANUAL Split System Heat Pump R2HM, R2H3, WCH3**2

TECHNICAL SUPPORT MANUAL Split System Air Conditioner H4A3, 3 Phase

Model G14SD Vapor Management System

Auto-Flo Panel Reinforcement Automatic Dispensing Valve

Installation Instructions

PLATFORM WELDER PACKAGE MANUAL

ERU ENERGY RECOVERY UNIT

Installation Instructions

MicroMetl INSTALLATION INSTRUCTIONS FOR 0689ZJ36EC

INSTALLATION INSTRUCTIONS

TECHNICAL SUPPORT MANUAL Fan Coils FSM4X6000AT

Galaxy VM. Battery Breaker Box Installation 09/

Package Unit Modulating Economizer Installation Instructions

Installation Instructions Read these instructions completely before attempting to install the Vertical EconoMi$er X Accessory.

Installation Instructions

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

Electronically Commutated Motor Wiring Manual

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

Emergency De-Icer (HSTAT-R Series) Instruction Manual

Installation Instructions

ERV ENERGY RECOVERY VENTILATOR 60 HZ. Indoor / Outdoor 500 to 10,000 cfm Capacity ERV I - D - D - P - 1 MODEL NUMBER IDENTIFICATION

Installation Instructions

Installation Instructions

Product Data FF1E LEGACY LINE FAN COIL SIZES 018 THRU 037 FEATURES

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS

A. NU2035 HRV Specifications NU2035

This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.

Transcription:

EnergyX R System Factory---Installed Energy Recovery Ventilator 48/50HC WeatherMasterr Commercial Rooftop Units 7.5 to 12.5 Nominal Tons with Puronr (R---410A) Refrigerant and ComfortLink Controls Supplemental Installation Instructions -- August 2016 This document is a supplemental Installation Instruction for the EnergyX factory-installed energy recovery ventilator. Use this document in conjunction with the following existing documents: Installation Instructions for the 48/50HC 6-10 ton and 48/50HC 12.5 ton rooftop units, ComfortLink Controls manual, and Supplemental Installation Instructions for the 48/50HC 3 to 12.5 ton Rooftop units with the EnergyX system. NOTE: Read the entire instruction manual before starting the installation. This supplement covers 48/50HC size 08, 09, 11, 12, and 14 units with the EnergyX (ERV) option. This supplement provides Physical Data and Airflow curves for units that have a 450 -mm (17.72 -in) electrically commutated backward -curved blower. Units that have a 500 -mm (19.69 -in) blower are not addressed in this supplement; data from previous literature provided with the unit is still applicable.

SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock or other conditions which may cause personal injury or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or agency must use factory-authorized kits or accessories when modifying this product. Refer to the individual instructions packaged with the kits or accessories when installing. Follow all safety codes. Wear safety glasses and work gloves. Use quenching cloths for brazing operations and have a fire extinguisher available. Read these instructions thoroughly and follow all warnings or cautions attached to the unit. Consult local building codes and appropriate national electrical codes (in USA, ANSI/NFPA 70, National Electrical Code (NEC); in Canada, CSA C22.1) for special requirements. It is important to recognize safety information. This is the safety-alert symbol. When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury. Understand the signal words DANGER, WARNING, CAUTION, and NOTE. These words are used with the safety-alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices, which may result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.! WARNING ELECTRICAL SHOCK HAZARD Failure to follow this warning could cause personal injury or death. Before performing service or maintenance operations on unit, always turn off main power switch to unit and install lock(s) and lockout tag(s). Unit may have more than one power switch. Ensure electrical service to rooftop unit agrees with voltage and amperage listed on the unit rating plate.! CAUTION UNIT DAMAGE HAZARD Failure to follow this caution may cause equipment damage. This unit uses a microprocessor-based electronic control system. Do not use jumpers or other tools to short out components or to bypass or otherwise depart from recommended procedures. Any short -to-ground of the control board or accompanying wiring may destroy the electronic modules or electrical components.! CAUTION CUT HAZARD Failure to follow this caution may result in personal injury. Sheet metal parts may have sharp edges or burrs. Use care and wear appropriate protective clothing, safety glasses and gloves when handling parts and servicing air conditioning equipment. 2

Table 1 Physical Data Model 48/50HC Sizes 08/09/11/12 (7.5/8.5/10/10 Ton) EnergyX Size NON ECONO CFM ECONO CFM EnergyX Unit Type Modulating Air Flow Capability ERV WHEEL OA (CFM) Range 900---2000 ERV WHEEL EA (CFM) Range 900---2000 ENERGY RECOVERY WHEEL Enthalpy Lightweight Polymer with Silica Gel Desiccant Coating MODEL (AirXchange) ERC-3019C SIZE (Dia. X Depth) (in.) 30 --- in x 3 --- in NOMINAL DRIVE MOTOR HP 0.10 SUPPLY FAN #1 1 - Backward Curved Direct (DIAMETER) 400mm (15.75--- in) NOMINAL MOTOR HP 1.2 SUPPLY FAN #2 NOMINAL MOTOR HP EXHAUST FAN #1 1 - Backward Curved Direct 450mm (17.72--- in) NOMINAL MOTOR HP 3.7 EXHAUST FAN #2 NOMINAL MOTOR HP FILTERS 2-in. Pleated, 30% Efficiency SUPPLY AIR (QTY) - SIZE (2) 16 --- in x 16 --- in x 2 --- in EXHAUST AIR (QTY) - SIZE (2) 16 --- in x 16 --- in x 2 --- in Aluminum Water Filter Water Entrapment (QTY) - SIZE (1) 35.75 --- in x 17.5 --- in x 1 --- in 3

Table 1 - Physical Data (cont) Model 48/50HC Size 14 (12.5 Ton) EnergyX Size NON ECONO CFM ECONO CFM EnergyX Unit Type Modulating Air Flow Capability ERV WHEEL OA (CFM) Range 1300---3675 ERV WHEEL EA (CFM) Range 1300---3675 ENERGY RECOVERY WHEEL Enthalpy Lightweight Polymer with Silica Gel Desiccant Coating MODEL (AirXchange) ERC-3628 SIZE (Dia. X Depth) (in.) 36 --- in x 3 --- in NOMINAL DRIVE MOTOR HP 0.05 SUPPLY FAN #1 1 - Backward Curved Direct (DIAMETER) 450mm (17.72--- in) NOMINAL MOTOR HP 3.7 SUPPLY FAN #2 NOMINAL MOTOR HP EXHAUST FAN #1 1 - Backward Curved Direct 450mm (17.72--- in) NOMINAL MOTOR HP 3.7 EXHAUST FAN #2 NOMINAL MOTOR HP FILTERS 2-in. Pleated, 30% Efficiency SUPPLY AIR (QTY) - SIZE (2) 16 --- in x 20 --- in x 2 --- in EXHAUST AIR (QTY) - SIZE (2) 16 --- in x 20 --- in x 2 --- in Aluminum Water Filter Water Entrapment (QTY) - SIZE (1) 48.219---in x 17.15---in x 1---in 4

3500 ECONOMIZER MODE 3000 ERV MODE 2500 2000 CFM 1500 1000 500 0 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 External Sta c Pressure (in H 2 O) Fig. 1-7.5, 8.5, 10 Ton Unit ERV Supply Exhaust Fan Performance Curves 5000 ECONOMIZER MODE 4500 ERV MODE 4000 3500 3000 CFM 2500 2000 1500 1000 500 0 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 External Sta c Pressure (in H 2 O) Fig. 2-12.5 Ton Unit ERV Supply Exhaust Fan Performance Curves 5

ECarrier Corporation 2016 Edition Date: 09/16 Printed in U.S.A. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Catalog No: ERV1 --- 8 --- 14 --- 01SI Replaces: New 8