Surge arrester POLIM-H..N

Similar documents
Surge arrester POLIM-H..SD

Surge arrester POLIM-H.. ND

Surge arrester POLIM-C.. HD

Voltage limiting device HVL

Voltage limiting device HVL

Zinc-Oxide Surge Arrester TEXLIM Q-C

Zinc Oxide Surge Arrester EXLIM R

Surge arresters Product overview

Overview Overvoltage protection

High Voltage Surge Arresters Buyer s Guide Section PEXLIM R

Product Brochure. Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant

Zinc Oxide Surge Arrester PEXLIM Q

High Voltage Surge Arresters Buyer s Guide Section PEXLIM P-Y

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

Product overview. ABB High Voltage Products Surge arresters

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

HIGH VOLTAGE SURGE ARRESTER SPECIFICATION

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

3EK7 Medium Voltage Silicone Insulated Surge Arresters

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers

Energy Division. PCA Single Column Polymeric Surge Arrester

Product brochure Generator circuit-breaker HVS-63S System type GCB with innovative built-in monitoring

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

CONTENTS About the company 1. Low-voltage arresters LVA type 2. Metal-oxide surge arresters for distribution systems. 3.

3EP1 Surge Arrester. Metal-oxide surge arrester without series gaps for high-voltage systems up to U m. = 170 kv

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

Electronic overload relays EF205 and EF370

PRODUCT BROCHURE. ABB Ability Wireless Monitor for surge arrester Enabling reliability and availability of power supply

BOWTHORPE EMP MCA/MDA SURGE ARRESTERS (IEC) ENERGY /// MCA/MDA SURGE ARRESTERS IEC

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance

BOWTHORPE EMP MEH SURGE ARRESTERS (IEC) ENERGY /// MEH SURGE ARRESTERS IEC

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

Electronic overload relay EF65, EF96 and EF146

GENERAL. CONSTRUCTION External

MEDIUM VOLTAGE NETWORKS

Thermal overload relay TF140DU and TF140DU-V1000

Type POLIM-S Surge Arresters Maximum System Voltage 2.52 to 245 kv

Mini contactors B6, BC6 with 3 pole

MEDIUM VOLTAGE PRODUCTS. Fault Current Limiters I S. -limiter and FC-Protector The worldʼs fastest switching devices

3EK7 Distribution Class Surge Arresters. Answers for energy.

ABB Switzerland Ltd Phone Surge arresters Telefax:

power pazifik Metal Oxide Surge Arrester with composite polymer insulator Type series SBK-I to IV /10.3

Low voltage bushings for pad-mounted distribution transformers Technical information guide

Low voltage capacitors CLMD Improving power factor and enhancing power quality of your network

Type HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv

EMPAC Metal enclosed capacitor bank for wind applications

3EK7 Distribution Class Surge Arresters. Answers for energy.

Surge arresters for railway applications. Product guide. Siemens HP-AR 41. siemens.com/arresters

ZX2 Gas-insulated medium voltage switchgear

Micafil transformer oil-sf 6 bushings GARIP / RTKG kv. Power and productivity for a better world TM ABB

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

MICAFIL RIP Transformer Bushings AirRIP / RTKF kv

Thermal overload relay TF65 and TF96

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

ABB MEASUREMENT & ANALYTICS DATA SHEET. Series and Katharometer power supply units

MEDIUM VOLTAGE PRODUCT. KECA 250 B1 Current Sensor Instructions for installation, use and maintenance

ZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket

3EP6 porcelain surge arrester

Manual motor starter magnetic only MO325

COMPONENTS. Off-load Switch for Fixed Installation Title type SW

ENERGY /// TRANSMISSION LINE SURGE ARRESTERS IEC. Bowthorpe EMP Transmission Line Surge Arresters (IEC)

SACE Emax 2/ML Low-voltage air circuit breakers for naval applications

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

LV Capacitors QCap-L series Capacitors for power factor correction

ZX-Family Gas-insulated medium voltage switchgear

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

MEDIUM VOLTAGE PRODUCT. KECA 80 C85 Current Sensor Instructions for installation, use and maintenance

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

MEDIUM VOLTAGE PRODUCT. KECA 80 D85 Current Sensor Instructions for installation, use and maintenance

I Surge Arresters. UltraSIL Polymer-Housed VariSTAR Type U3 Surge Arrester for Systems through 275 kv IEC 10 ka; Line Discharge Class 3 GENERAL

Selective main circuit breakers S 750 series Technical Data

Station Class Polymeric Surge Arresters

Surge Arrester 3EL2 superior protection up to 550 kv

3EQ Composite Housed Surge Arresters Saving Money and Space, Gaining Reliability

Directly Molded Polymer Surge Arresters

Bowthorpe EMP LV/MV Outdoor Surge Arresters

ZK2.5-D-CH PI-Spring Terminal Blocks Component holder

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

ZK2.5-SP PI-Spring Terminal Blocks Disconnect with plug - with test sockets

Thermal Overload Relays

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

ZS4-D-CH Screw Clamp Terminal Blocks Component holder

VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified

Transformer bushings, type GOH. Technical guide

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Outdoor vacuum breaker for railway applications - FSK II

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

3EQ Composite Housed Surge Arresters

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

MKV-Capacitor B25836-A4197-A372 4RB AB 40

ZS10-ST Screw Clamp Terminal Blocks Test disconnect with sliding link

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Manual motor starter MS116

VariSTAR Type AZG2 Surge Arrester, 10,000 A, Line Discharge Class 2 IEC (99-4)

Transcription:

Data sheet Surge arrester POLIMH..N Technical data Arrester class SH, Station High Line discharge class (LD) 4 Nominal discharge current I n (8/20 µs) 20 ka peak Repetitive charge transfer rating Q rs 2.4 As ( C ) Rated thermal energy W th at T amb = 40 C 12 kj/kv (U r ) = 15 kj/kv (U c ) W th at T amb = 55 C 10.5 kj/kv (U r ) = 13.1 kj/kv (U c ) High current impulse I hc (4/10 µs) 100 ka peak Long duration current impulse 1350 A for 2000 µs Shortcircuit rating I s (50Hz) 63 ka rms for 0.2 s Product description Surge arrester with metal oxide resistors without spark gaps (MO surge arrester), direct molded silicone housing, grey color, designed and tested according to IEC 600994. Overvoltage protection of Transformers Motors and cable terminations Cable sheaths Traction systems fixed installations Rolling stock and high speed trains Capacitors and capacitor banks Medium voltage equipment Application Systems with alternating current (AC) Outdoor and indoor installations Generators Cables Additional certification Fire and smoke behaviour tested and classified according to EN 455452 Power frequency voltage versus time characteristic (TOV) without prior duty energy input U TOV at t = 1 s 1.125 U r = 1.406 U c U TOV at t = 3 s 1.090 U r = 1.363 U c U TOV at t = 10 s 1.060 U r = 1.325 U c Power frequency voltage versus time characteristic (TOV) with prior duty energy input of 10.5 kj/kv (U r ) = 13.1 kj/kv (U c ) U TOV at t = 1 s 1.105 U r = 1.381 U c U TOV at t = 3 s 1.074 U r = 1.342 U c U TOV at t = 10 s 1.033 U r = 1.291 U c Mechanical loads Torque 100 Nm Tensile strength axial 4000 N Short term load SSL perpendicular to axis 4000 Nm Long term load SLL perpendicular to axis 2000 Nm Service conditions Ambient air temperature T amb (for temperatures up to 80 C consider instructions of application guidelines) Altitude up to 1800 m (for higher altitudes contact manufacturer) Frequency of system voltage 16.7/50/60 Hz

Electrical data U c U r Residual voltage U res at specified impulse current Continuous operating voltage Rated voltage Steep current impulse wave 1/ µs Lightning current impulse wave 8/20 µs Switching current impulse wave 30/60 µs 10 ka 20 ka 2 ka 5 ka 10 ka I n=20 ka 40 ka 500 A 1000 A 2000 A kv rms kv rms kv peak kv peak kv peak kv peak kv peak kv peak kv peak kv peak kv peak kv peak 4 5.0 12.7 13.6 10.6 11.2 11.6 12.7 14.2 9.8 10.1 10.4 5 6.3 15.9 17.0 13.3 13.9 14.5 15.9 17.7 12.3 12.6 13.0 6 7.5 19.0 20.4 15.9 16.7 17.4 19.0 21.3 14.7 15.2 15.6 7 8.8 22.2 23.8 18.6 19.5 20.3 22.2 24.8 17.2 17.7 18.2 8 10.0 25.3 27.2 21.2 22.3 23.2 25.3 28.4 19.6 20.2 20.8 9 11.3 28.5 30.6 23.9 25.1 26.1 28.5 31.9 22.1 22.7 23.4 10 12.5 31.7 34.0 26.5 27.8 29.0 31.7 35.4 24.5 25.2 26.0 11 13.8 34.8 37.4 29.2 30.6 31.9 34.8 39.0 27.0 27.7 28.6 12 15.0 38.0 40.8 31.8 33.4 34.8 38.0 42.5 29.4 30.3 31.2 13 16.3 41.1 44.2 34.5 36.2 37.7 41.1 46.0 31.9 32.8 33.8 14 17.5 44.3 47.6 37.1 38.9 40.6 44.3 49.6 34.3 35.3 36.4 15 18.8 47.5 50.9 39.8 41.7 43.5 47.5 53.1 36.8 37.8 39.0 16 20.0 50.6 54.3 42.4 44.5 46.4 50.6 56.7 39.2 40.3 41.6 17 21.3 53.8 57.7 45.1 47.3 49.3 53.8 60.2 41.7 42.8 44.2 18 22.5 56.9 61.1 47.7 50.1 52.2 56.9 63.7 44.1 45.4 46.8 19 23.8 60.1 64.5 50.4 52.8 55.1 60.1 67.3 46.6 47.9 49.4 20 25.0 63.3 67.9 53.0 55.6 58.0 63.3 70.8 49.0 50.4 52.0 21 26.3 66.4 71.3 55.7 58.4 60.9 66.4 74.3 51.4 52.9 54.6 22 27.5 69.6 74.7 58.3 61.2 63.8 69.6 77.9 53.9 55.4 57.2 23 28.8 72.8 78.1 60.9 63.9 66.7 72.8 81.4 56.3 57.9 59.7 24 30.0 75.9 81.5 63.6 66.7 69.6 75.9 85.0 58.8 60.5 62.3 25 31.3 79.1 84.9 66.2 69.5 72.5 79.1 88.5 61.2 63.0 64.9 26 32.5 82.2 88.3 68.9 72.3 75.4 82.2 92.0 63.7 65.5 67.5 27 33.8 85.4 91.7 71.5 75.1 78.3 85.4 95.6 66.1 68.0 70.1 28 35.0 88.6 95.1 74.2 77.8 81.2 88.6 99.1 68.6 70.5 72.7 29 36.3 91.7 98.4 76.8 80.6 84.1 91.7 102.7 71.0 73.0 75.3 30 37.5 94.9 101.8 79.5 83.4 87.0 94.9 106.2 73.5 75.6 77.9 31 38.8 98.0 105.2 82.1 86.2 89.9 98.0 109.7 75.9 78.1 80.5 32 40.0 101.2 108.6 84.8 89.0 92.8 101.2 113.3 78.4 80.6 83.1 33 41.3 104.4 112.0 87.4 91.7 95.7 104.4 116.8 80.8 83.1 85.7 34 42.5 107.5 115.4 90.1 94.5 98.6 107.5 120.3 83.3 85.6 88.3 35 43.8 110.7 118.8 92.7 97.3 101.5 110.7 123.9 85.7 88.2 90.9 36 45.0 113.8 122.2 95.4 100.1 104.4 113.8 127.4 88.2 90.7 93.5 37 46.3 117.0 125.6 98.0 102.8 107.3 117.0 131.0 90.6 93.2 96.1 38 47.5 120.2 129.0 100.7 105.6 110.2 120.2 134.5 93.1 95.7 98.7 39 48.8 123.3 132.4 103.3 108.4 113.1 123.3 138.0 95.5 98.2 101.3 40 50.0 126.5 135.8 106.0 111.2 116.0 126.5 141.6 98.0 100.7 103.9 41 51.3 129.7 139.2 108.6 114.0 118.9 129.7 145.1 100.4 103.3 106.5 42 52.5 132.8 142.6 111.3 116.7 121.8 132.8 148.6 102.8 105.8 109.1 43 53.8 136.0 145.9 113.9 119.5 124.7 136.0 152.2 105.3 108.3 111.7 44 55.0 139.1 149.3 116.5 122.3 127.6 139.1 155.7 107.7 110.8 114.3 2 POLIMH Surge arrester

Housing U c Creepage Flashover Recommended Height H Weight Insulation withstand voltage of empty housing Continuous distance distance minimum clearances operating 50 Hz, 60 s wet condition voltage E min F min required guaranteed required guaranteed values values acc. to IEC acc. to IEC kv rms mm mm mm mm mm kg kv peak kv peak kv rms kv rms 4 358 196 100 190 210 5.7 17 118 8 34 5 358 196 101 190 210 5.8 21 118 10 34 6 493 227 111 190 240 6.6 25 137 12 39 7 493 227 121 190 240 6.7 29 137 14 39 8 493 227 131 190 240 6.8 33 137 16 39 9 648 277 141 191 290 8.0 38 167 18 48 10 648 277 151 201 290 8.1 42 167 20 48 11 648 277 161 211 290 8.2 46 167 22 48 12 648 277 171 221 290 8.3 50 167 24 48 13 823 346 181 231 360 10.0 54 208 26 59 14 823 346 191 241 360 10.1 58 208 28 59 15 823 346 201 251 360 10.2 62 208 30 59 16 823 346 212 261 360 10.3 66 208 32 59 17 823 346 221 271 360 10.4 70 208 34 59 18 823 346 231 281 360 10.6 74 208 36 59 19 823 346 242 292 360 10.7 79 208 38 59 20 823 346 252 301 360 10.8 83 208 39 59 21 978 396 262 311 410 12.0 87 238 41 68 22 978 396 272 322 410 12.1 91 238 43 68 23 978 396 282 332 410 12.2 95 238 45 68 24 978 396 292 342 410 12.3 99 238 47 68 25 978 396 302 352 410 12.4 103 238 49 68 26 1133 446 312 362 460 13.7 107 268 51 76 27 1133 446 322 372 460 13.8 112 268 53 76 28 1133 446 332 382 460 13.9 116 268 55 76 29 1133 446 342 392 460 14.0 120 268 57 76 30 1423 527 352 402 540 16.0 124 317 59 90 31 1423 527 362 412 540 16.1 128 317 61 90 32 1423 527 372 422 540 16.2 132 317 63 90 33 1423 527 382 432 540 16.3 136 317 65 90 34 1423 527 392 442 540 16.4 140 317 67 90 35 1423 527 402 452 540 16.6 144 317 69 90 36 1423 527 412 462 540 16.7 148 317 71 90 37 1597 596 423 472 610 18.0 153 358 73 102 38 1597 596 432 482 610 18.1 157 358 74 102 39 1597 596 442 492 610 18.2 161 358 76 102 40 1597 596 453 502 610 18.3 165 358 78 102 41 1733 627 463 512 640 19.3 169 377 80 107 42 1733 627 473 522 640 19.4 173 377 82 107 43 1733 627 483 533 640 19.5 177 377 84 107 44 1733 627 493 543 640 19.6 181 377 86 107 Surge arrester POLIMH 3

TOV and Dimensions Powerfrequency voltageversustime characteristic (TOV) based on U r Powerfrequency voltageversustime characteristic (TOV) based on U c Ì ã Ë ÌÑÊ ñ ïòîë ïòîð ïòïë ïòïð ïòðë ïòðð ðòçë ðòçð ðòèë ðòèð ïòðð ðòðï ðòï ï ïð ïðð ïððð ïðððð ðòðï ðòï ï ïð ïðð ïððð ïððð𠱫± ¼²» ¹ ² «ô ²¹»³» êðpý ñ ±«± ¼²» ¹ ² «ô ²¹»³» êð pý ñ ± ¼«ïðòë µöñµê ø ã ïíòï µöñµê ø ½»²» ¹ ² «ô ²¹»³» êðpý ± ¼«ïðòë µöñµê ø ã ïíòï µöñµê ø ½»²» ¹ ² «ô ²¹»³» êðpý Ì ã Ë ÌÑÊ ñ ½ ïòêð ïòëð ïòìð ïòíð ïòîð ïòïð Dimensions (mm) Dimensions according to outline drawing HAAR481686 Outline drawings with accessories on request Structure of type designation (Example) POLIMH 36 N Type of arrester U c = Continuous operating voltage Housing Structure of type designation with optional accessories (Example) POLIMH 36 N / 1200 / 2200 Type of surge arrester Type of top accessory (optional) Type of bottom accessory (optional) 4 POLIMH Surge arrester

Common Top Accessories (optional) Dimensions (mm) Type 1200 Flat terminal (aluminium alloy) Type 1201 Flat terminal (stainless steel) Type 1220 Stud ø 30 x 80 (stainless steel) Type 1209 Line terminal (bracket: aluminium alloy, other parts: stainless steel) Surge arrester POLIMH 5

Common Bottom Accessories (optional) Dimensions (mm) 3points base R = 130 (galvanized steel) Type 2200 Type 2201 (insulated) 3points base R = 95 (galvanized steel) Type 2202 Type 2203 (insulated) 6 POLIMH Surge arrester

Common Bottom Accessories (optional) Dimensions (mm) Type 2204 3points reinforced base R = 130 for railway application (aluminium alloy) Type 2206 3points reinforced base R = 95 for railway application (aluminium alloy) Type 2225 3points reinforced base R = 80 for all application (aluminium alloy) Surge arrester POLIMH 7

For further information please contact: ABB Switzerland Ltd High Voltage Products Surge Arresters Jurastrasse 45 CH5430 Wettingen/Switzerland Tel. +41 58 585 29 11 Fax +41 58 585 55 70 Email: sales.sa@ch.abb.com www.abb.com/arrestersonline Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG. Copyright 2015 ABB All rights reserved Our products are certified according ISO 9001, 14001, 18001 and IRIS 1HC0075856 EN AD For detailed information regarding the dimensioning of our products see the following ABB documents: Application guidelines Overvoltage protection Metal oxide surge arresters in medium voltage systems Application guidelines Overvoltage protection Metal oxide surge arresters in railway facilities For pdf or print version please send Email to: sales.sa@ch.abb.com