BEST PRACTICE CEBP9801. Controls Engineering COE. DATE: May, 1998 Delphi Controls COE Best Practice - Flexible Utility Connections

Similar documents
PDI PowerWave 2 Bus System

Ground Mount / Piping / Electrical Quick Reference ECS Membrane Processor: PMC and ISD

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

Conduit and Wire. Wire and Cable Whips. Bus Duct, Cable Trays, Overhead or Under Floor Raceways, Strut or Channel Systems

Users Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions

10 Commercial, Industrial, Agricultural Services

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Quik-Spec Coordination Panelboard Specifications

Put the Power in Your Hands

INLINE 1100 COMPACT, MULTI-PUMP SYSTEM. franklinwater.com

Utility Distribution Systems Installation, Operation, and Maintenance Manual

COMPACT BUSWAY 40 & 60 AMP HOUSING

UTILITY DISTRIBUTION SYSTEMS

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

PRE-INSTALLATION GUIDE

INLINE 1100 COMPACT, MULTI-PUMP SYSTEM

AD-830. Parts Manual thru 1997

PBA Series Prelube Controls

PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST

Service Requirements

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE

Busway Construction. Bus Bars

Form No CE Parts List for:

AMENDMENT ELECTRIC SERVICE MANUAL 2014

SECTION PANELBOARDS

Dry Vacuum System. Part Numbers: V15, 2V15, 3V15 and 4V15 USER S MANUAL. Recommend Daily use of Monarch CleanStream

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

SERVICE BULLETIN SB1212

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

PLASTIC FOLDING ARM KIT This kit is designed for the 1600 model barrier gate operators only. Recommended for low headroom applications.

READ INSTRUCTIONS THOROUGHLY BEFORE OPERATING TC-6 TC-15 TC Fax

SECTION 300 OVERHEAD SERVICE

DIVISION 16 - ELECTRICAL SECTION 16xx0 MANUFACTURED WIRING SYSTEM ACCESS FLOOR

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST

University of California, San Diego Cal (IT) 2 Technical Assignment #2. Brian Smith

INLINE 1100 STAGED PALLET SYSTEM. franklinwater.com

7. Residential Single-Family and Duplex Buildings (Dwellings)

Pyrolance, LLC SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D

Harbor Light Model HL General Specifications

A. This section includes unit capacitors for power factor correction.

Table Summary of Sprinkler System Inspection, Testing, and Maintenance. Reference. Inspection , ,

7 Single Family Service

PRODUCT NUMBERING SYSTEM SERIES PHASE. HD: Heavy Duty (15,000+ hour life) SD: Standard Duty (5,000+ hour life) LD: Light Duty (2,000+ hour life)

Generator Fire Safety: Generator assemblies should be located outside the building.

Lighthouse Power Pedestals,

INTELLIGENT MEDIUM POWERBAR impb

6,000 Watt Generator Item No. PS906025PA Mfg. No Replacement Parts List

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

COMMANDER PRO VARIABLE FREQUENCY DRIVES

POWERBUS 225 Busway and Plug-In Units

SUPER 30 AUTO EJECT -AE

Procenter Delivery, Console Mounted on an Elevance Chair Installation Guide

Packaged Pump Sets FOR DIESEL FUEL OIL APPLICATION. Packaged Pump Sets for Diesel/Fuel Oil Application Page 1

Installation Instructions

Service Requirements

FLO Home TM G5 Model. Installation guide

East Central College

Installation Instructions Capacity 10,000 lbs. (100 Series Lift)

Capital Projects Group General Service Compressed Air System Specification

Commander Pro 100 SUBMERSIBLE SYSTEM Installation, Operation and Trouble-Shooting Manual

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals

Service Entrance Methods

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

Lifeline Medical Systems

Installation Instructions

M-3025CB-AV Fuel Pump

Woda-Sci System Installation Parts Set

Wire Management Products Index

GVB-8 (Boost) Manual

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

ECET 211 Electric Machines & Controls Lecture 1-3 (Part 2) Electrical Safety in the Workplace Electrical Safety in the Workplace

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

A. This section includes enclosed dry type transformers for lighting and power loads, with primaries and secondaries rated 600 volts and less.

168 Georgetown Road Canonsburg, PA USA Phone: Toll Free: Fax:

Owner s Manual. For Automatic Transfer Switch. 50 & 100 Amp. Model Number RTG10EZA1 RTG12EZA1 RTG16EZA1 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:

Control Panel Interface Upgrade Installation Guide For Model 200i and 250i Motorcycle Dynamometers Serial Number 202xxxx.

A. Submit manufacturer's literature and technical data before starting work.

Solar Combiner Solutions

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

Index. Flexcor Wire Mesh Grips K-1

University of Delaware

Temperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

GE 8000-Line Motor Control Centers

Therm-L-Tec Building Systems LLC. Therm-L-Tech. Power Operated Retrofit Kit 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

General Specifications for Lighthouse Power Pedestal

SUBMITTAL DATA WATER PRESSURE BOOSTER SYSTEMS

Pre-plumbed Blowdown Assembly ½ Model

User s and Installation Manual

Power Operated Retrofit Kit for Manual Door 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

Hydropak Booster Systems. Series motralec

8300 Series Installation Guidelines

PARTS LIST PONY 20 SCA

Installation & Operating Manual

PITNEY BOWES FLEXIBLE INK JET TRANSPORT 36 FIT BASE: FIT-36. Parts Manual. (BOM: FIT36rev1.0) FIT-36parts_rev0 1

Pole Mount COD Installations (PMCOD)

Transcription:

BEST PRACTICE CEBP9801 Controls Engineering COE DATE: May, 1998 RE: Delphi Controls COE Best Practice - Flexible Utility Connections EXECUTIVE SUMMARY: The Delphi Automotive Controls Engineering COE has compiled several drawings showing best practice methods to install flexible utilities for lean manufacturing. These drawings are based on the National Electrical Code, NFPA 79 and the experience of several Delphi Automotive plant sites. ATTACHMENTS: Best Practice CEBP9801.PPT Flexible Utility Connections DESCRIPTION: Drawing 1 illustrates a method of installing 460 volt, 3 phase power drops using standard bus drop hardware. The hardware chosen allows coiling some spare cable above the machine and easily relocating the attachment when the machine is moved to keep the vertical riser plumb. The National Electrical Code does not specify a maximum current for flexible drops. Wire sizes larger than 6 AWG (60 amp drop)are not recommended because of the higher bus drop cable costs and the difficulty in working with the larger cable. Rigid conduit with a flexible section to allow some movement should be considered for 100 amp or larger currents. Drawing 2 illustrates a method of installing 115/230 volt, 1 phase power drops using standard electrical wireway, plugs and connectors. Each drop is wired back to an individual fuse or circuit breaker connected to a suitable 115/230 volt, 1 phase power source. The wireway is installed above the machines in the shape of the cell. Drawing 3 illustrates a method of installing 115/230 volt, 1 phase power drops using plug-in busway. The busway is wired to fuses or a circuit breaker connected to a suitable 115/230 volt, 1 phase power source. Each machine is connected to the busway using a fused bus plug. Optional plugs and connectors may be used to connect any or all machines. The busway is installed above the machines in the shape of the cell. This method facilitates the easy relocation of the entire cell. Drawing 4 illustrates a method of installing a flexible air drop using the same hardware used for installing 460 volt, 3 phase power drops (drawing 1). The hardware chosen allows coiling some spare hose above the machine and easily relocating the attachment when the machine is moved to keep the vertical riser plumb. Drawing 5 illustrates a method of installing flexible air drops to several machines in a cell. The header is connected to a lockable safety shut-off valve located at floor level. The safety shut-off valve is connected to the nearest factory air supply header. The header is installed above the machines in the shape of the cell. This method facilitates the easy relocation of the entire cell. Page 1 of 1

FLEXIBLE POWER DROP 460 VOLTS, 3 PHASE, 60 AMPS MAXIMUM BRIDLE RINGS (TYPICAL) ATTACH TO BUILDING STEEL IF POSSIBLE. ADD ADDITIONAL SUPPORT STEEL AS NEEDED. 2 MINIMUM AND 6 MAXIMUM CABLE SAG CABLE SUPPORT RESTRAINT- ADALET SH-XX SKY-TIE BUSWAY 8-0 MAX. BETWEEN CABLE SUPPORTS BUS PLUG LISTED BUS DROP CABLE #10 AWG FOR 30 AMP BUSPLUG #6 AWG FOR 60 AMP BUSPLUG STRAIN RELIEF DEVICES- KELLEMS DELUXE CORD GRIPS 074-01-015 FOR #10 AWG 074-01-023 FOR #6 AWG MAXIMUM OF 10 SPARE CABLE SPRING ADELET SHS-75 BUS DROP CABLE CLAMP- ADALET SH-XX SKY-TIE AND SHD-XX DUPLEX COMPONENT VERTICAL RISER SHOULD BE PLUMB REFERENCE: 1996 NATIONAL ELECTRICAL CODE ARTICLE 364-8 BRANCHES FROM BUSWAYS CONTROL ENCLOSURE Delphi Automotive Controls COE, May 1998. Best Practice # CEBP9801 Drawing 1 of 5

FLEXIBLE POWER DROP 115/230 VOLT, 1 PHASE, 30 AMPS MAXIMUM WITH WIREWAY WIREWAY WIREWAY HANGERS SUPPORTED FROM BUILDING STEEL STRAIN RELIEF DEVICES- KELLEMS DELUXE CORD GRIPS #074-01-018 NOTES: EACH DROP WIRED BACK TO INDIVIDUAL FUSE OR CIRCUIT BREAKER. PLUG AND CONNECTOR. HUBBELL TWIST-LOCK OR EQUIV, NEMA RATED WITH GROUND. REFERENCE NFPA 79 CLUASE 7.11. FLEXIBLE CABLE PER NFPA 79 CLAUSE 15.1.2 CONTROL ENCLOSURE 1. ALL REFERENCES TO NFPA 79 ARE FOR THE 1994& 1997 EDITIONS AND THE DELPHI AUTOMOTIVE ADDENDUM TO NFPA 79. 2. EACH MUST HAVE A LOCKOUT MEANS, EITHER A LOCKABLE SWITCH OR A LOCKING DEVICE TO GO OVER THE PLUG. Delphi Automotive Controls COE, May 1998. Best Practice # CEBP9801 Drawing 2 of 5

FLEXIBLE POWER DROP 115/230 VOLT, 1 PHASE, 30 AMPS MAXIMUM WITH PLUG-IN BUSWAY 115/230 VOLT, 1 PHASE PLUG-IN BUSWAY BUSWAY HANGERS SUPPORTED FROM BUILDING STEEL BUS PLUG WITH FUSE OR CIRCUIT BREAKER STRAIN RELIEF DEVICES- KELLEMS DELUXE CORD GRIPS #074-01-018 NOTES: OPTIONAL PLUG AND CONNECTOR. HUBBELL TWIST-LOCK OR EQUIV, NEMA RATED WITH GROUND. REFERENCE NFPA 79 CLUASE 7.11. FLEXIBLE CABLE PER NFPA 79 CLAUSE 15.1.2 CONTROL ENCLOSURE 1. ALL REFERENCES TO NFPA 79 ARE FOR THE 1994& 1997 EDITIONS AND THE DELPHI AUTOMOTIVE ADDENDUM TO NFPA 79. 2. EACH MUST HAVE A LOCKOUT MEANS, EITHER A LOCKABLE SWITCH OR A LOCKING DEVICE TO GO OVER THE OPTIONAL PLUG. Delphi Automotive Controls COE, May 1998. Best Practice # CEBP9801 Drawing 3 of 5

FLEXIBLE AIR DROP BRIDLE RINGS (TYPICAL) ATTACH TO BUILDING STEEL IF POSSIBLE. ADD ADDITIONAL SUPPORT STEEL AS NEEDED. 2 MINIMUM AND 6 MAXIMUM HOSE SAG CABLE SUPPORT RESTRAINT- ADALET SH-XX SKY-TIE 8-0 MAX. BETWEEN HOSE SUPPORTS MAXIMUM OF 10 SPARE HOSE PUSH ON TYPE HOSE, MINIMUM 300 PSI WORKING PRESSURE. LABELED FOR PUSH-ON HOSE FITTING PUSH-ON SERVICE. BALL VALVE AIR SUPPLY OVERHEAD PIPING IN PLANT. NOTE: HOSE MUST BE CHECKED ANNUALLY FOR CRACKING OR OTHER SIGNS OF DETERIORATION AND REPLACED IF NEEDED. WHIP CHECK REQUIRED. KELLEMS SINGLE EYE BUS DROP GRIP # 073-04-12XX OR EQUIV. CONNECT GRIP EYE TO STAND PIPE WTTH HOSE CLAMP. CONTROL ENCLOSURE AIR FEED TO DRIP LEG SPRING ADELET SHS-75 BUS DROP CABLE CLAMP- ADALET SH-XX SKY-TIE AND SHD-XX DUPLEX COMPONENT HOSE VERTICAL RUN SHOULD BE PLUMB PUSH-ON HOSE FITTING STAND PIPE - 7.5 FT. MINIMUM HEIGHT FROM WORKING SURFACE. ATTACH TO. LOCKABLE SAFETY SHUT-OFF VALVE, WITH VENT, LOCATED NEAR OTHER UTILITY LOCK-OUTS. Delphi Automotive Controls COE, May 1998. Best Practice # CEBP9801 Drawing 4 of 5

FLEXIBLE AIR DROP WITH HEADER PIPE HANGERS SUPPORTED FROM BUILDING STEEL PIPE HEADER WITH TEES FOR AIR DROPS BALL VALVE AND PUSH-ON HOSE FITTING CONTROL ENCLOSURE PUSH ON TYPE HOSE, MINIMUM 300 PSI WORKING PRESSURE. LABELED FOR PUSH-ON SERVICE. WHIP CHECK NOTE: HOSE MUST BE CHECKED ANNUALLY FOR CRACKING OR OTHER SIGNS OF DETERIORATION AND REPLACED IF NEEDED. SEE SLIDE 4 FOR DETAILS SHUTOFF VALVE DRIP LEG Delphi Automotive Controls COE, May 1998. Best Practice # CEBP9801 Drawing 5 of 5