INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

Similar documents
READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

INSTALLATION INSTRUCTIONS

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit

OSQ Series IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Area Light TO INSTALL:

Specification Grade Contemporary Wall Mount/Technical Installation Data

Captivate Illuminated Mirror Light

INSTALLATION GUIDE Works in double and single ended wiring.

MAXLITE RKT LED Retrofit Kit

LS1 SERIES IMPORTANT: READ ALL INSTRUCTIONS THOROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF LINEAR SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE.

ELV1abbccd-e. Color Temperature: 30 = 3000K White 35 = 3500K White 40 = 4000K White 45 = 4500K White 50 = 5000K White

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

MOONRING 1.5 MOONRING 3

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised:

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS

Universal Retrofit System Installation Instructions Revised:

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame

INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight

LED 2/3/4ft T8 Tube 120V

Wet Rated Batten LED Luminaire

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

Cable Cubby 1202 and 1402 Installation Guide

Lumination TM LED Luminaires LAL Series - Continuous Run Option

Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps

GETTING STARTED WITH IN-WALL DIMMER SWITCH

IMMERSION. imagination at work. Retrofit Installation Guide. GE Lighting. LED Refrigerated Display Lighting

Tetra minimax. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide

UB-2 2 Universal Button

INSTALLATION INSTRUCTION Bollard Light 12V

LAL SERIES LED LUMINAIRE

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

Lumination TM LED Luminaires Suspended LED Fixture (Series EP14)

Spun Bay Installation Standard Version (non dimmable), Hook Mount

WARNING / AVERTISSEMENT

LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series)

Have a Bright Day! Nicholas Harmon President, Verilux, Inc.

OPTIMAX RADIANT FIELD RETROFIT INSTRUCTIONS

Installation Instructions: External-Driver SEP T8 LED Tube Lamp

Installation Guide. WARNINGS Read all instructions and warnings before attempting installation

INSTALLATION INSTRUCTION Oculux 3.5" Architectural Downlight R3CRN-11, R3CSN-11

Installation Instructions


I. Pendant Mount Installation

INSTALLATION INSTRUCTIONS

Cable Cubby 500 and 700 Installation Guide

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

Cable Cubby 1200 and 1400 Installation Guide

WARNING/AVERTISSEMENT. Coupez l alimentation électrique à la boîte de fusibles ou au disjoncteur avant servicing or installing product.

Installation Instructions

TECTONIC LED CORP. ISO

QTM-eLED INSTALLATION INSTRUCTIONS Must be installed by licensed electrician.

Installation Instructions

IMMERSION. GE Lighting. OEM Installation Guide. imagination at work. LED Display Lighting

Product Installation Instruction LED Tube Lamp Retrofit Kits

Cable Cubby 650 UT Installation Guide

IMMERSION. imagination at work. LED Refrigerated Display Lighting. Vertical Cases RV40 Series LED Drivers GEPS4000NCMUL-SY

Installation Instructions BLTR and 2BLTR Relight Assembly

OmniAire Omnitec Design, Manufacturing Air Purification Equipment Since 1988

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

Horticulture Batten LED Luminaire

960 Montage sur staff préfabriqué Mounting in prefabricated plaster

Installation Instructions

Lumination TM LED Luminaire LUR Series

Have a bright day! Nicholas Harmon President, Verilux, Inc.

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS ModuSys LED Retrofit Kit 2x2, rev. D.02

LED Recessed Troffer Retrofit Kit

Installation Instructions

LED IMPORTANT SAFETY INSTRUCTIONS

Installation Instructions

INSTALLATION INSTRUCTION

Instruction/Installation Manual

INSTALLATION INSTRUCTION

A1100 GUARDIAN OVERFILL PREVENTION SYSTEM

Installation Instructions

Troubleshooting Guide

A1100 GUARDIAN OVERFILL PREVENTION VALVE (with Installation Kit)

Installation Instructions Sero / Qub Pendant RETROFIT CONSTRUCTION- INACCESSIBLE CEILING Mounting Option GP

Optimax Pro Retrofit Instructions

HOMELINK DOOR OPENER KIT

Lumination TM LED Luminaire (IS Series)

INSTALLATION INSTRUCTION Magnetic Transformer

STOP BEFORE YOU BEGIN READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY

INSTALLATION GUIDE FOR VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

Installation Instructions

INSTALLATION INSTRUCTIONS

LUNERA T8 LED RETROFIT KITS 1/2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps

RSA-MRZ Installation Instructions

UNPACKING THE UNIT. Alcohol cleaning pad

CSR COMPACT FUSED INTERLOCKED ARKTITE RECEPTACLE - 30 & 60 AMP Installation & Maintenance Information IF 1440

RAPID SHUTDOWN COMBINER

Fan Relay Board (FRBii) Assembly

M Remote Mounting Kit

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

RSA-MRZ Installation Instructions

poollux Power plx-pw60 & plx-pw100

Transcription:

SAFETY S IMPORTANT SAFETY INFORMATION SUITABLE FOR DRY OR DAMP LOCATIONS. NOT FOR USE WITH PHASE CUT DIMMERS. Risk of shock. Disconnect power before installation. DANGER CONVIENT AUX EMPLACEMENTS HUMIDES. DANGER- RISQUE DE CHOC- COUPER L ALIMENTATION AVANT L INSTALLATION NE PAS UTILISER AVEC GRADATEUR À COUPURE DE PHASE. Risk of fire or electric shock. LED Retrofit Assembly installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Product must be installed in accordance with NEC or your local electrical code. If you are not familiar with these codes and requirements, contact a qualified electrician. ATTENTION- Risque d incendie ou de choc électrique. L installation du kit upgrade LED exige Ia connaissance des systèmes électriques pour luminaires. Si non qualifié, ne tentez pas d installation. Ce produit doit être installé conformément à NEC ou votre code électrique local. Si vous n êtes pas familier avec ces codes et ces exigences, veuillez contacter un électricien qualifié. Risk of fire or electric shock. To prevent wiring damage or abrasion, do not expose wires to the edge of sheet metal or any other sharp objects. ATTENTION- Pour éviter les dégâts de câblage par l abrasion, ne pas mettre en contact les fils électriques avec des bords de tôle ou d autres objets pointus. Risk of fire or electric shock. Install this assembly only in luminaires that have the construction features and dimensions shown in the photographs and/or drawings. ATTENTION- Risque d incendie ou de choc électrique. lnstallez ce kit seulement dans les luminaires qui ont les caractéristiques de construction et les dimensions dans les photographies ou les dessins de Ia page suivante. Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation. IL EST INTERDIT DE FAIRE OU DE MODIFIER UNE OUVERTURE DANS UN BOÎTIER DE CÂBLAGE OU DE COMPOSANTS ÉLECTRIQUES AU COURS DE L INSTALLATION DU NÉCESSAIRE. Risk of fire or electric shock. Check the existing wiring for damage before Installing upgrade assembly. Do not install if existing wires are damaged. ATTENTION- Risque d incendie ou de choc électrique. Vérifier si le câblage existant n est pas endommagé avant l installation du kit upgrade LED. Ne pas installer si des fils sont endommagés. Risk of fire or electric shock. Luminaire wiring and electrical parts may be damaged when drilling for installation of the LED upgrade assembly. Check for enclosed wiring and components. ATTENTION- Risque d incendie ou de choc électrique. Câblage électriques peuvent être endommagés Iors du perçage pour l installation du kit upgrade LED. Vérifier les fils et composants. NOTE THE RETROFIT ASSEMBLY IS ACCEPTED AS A COM- PONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY CSA OR AUTHORITIES HAVING JURISDICTION. LE NÉCESSAIRE DE MODERNISATION EST ACCEPTÉ À TITRE DE COMPOSANT D UN LUMINAIRE LORSQUE LA PERTINENCE DE LA COMBINAISON DOIT ËTRE DÉTERMINÉE PAR LA CSA OU PAR LES AUTORITÉS COMPÉTENTES. UNPACKING THE KIT For installation in 4ft or 8ft strip-style luminaires, suitable for dry or damp locations, with min. 4 inch width and 1-11 / 16 inch depth. Supplied Components: (1) Preassembled EVERLINE LED 4 Assembly Panel with: (1) EVERLINE LED Lensed Module (1) EVERLINE Driver Associated connectors and wires (1) Preassembled EVERLINE LED 4 Assembly Panel (LRA28 only) with: (1) EVERLINE LED Lensed Module (1) Ground screw in bag. NOTE: Consult your local authority regarding disposal or recycling procedures of removed ballast and lamps. Page 1

Fig. 1 Step 1: Verify the fluorescent fixture is a 4ft or 8ft strip fixture of appropriate dimensions as shown in Figure 1. For Fig. 6 fixtures that are connected together in series on the same branch circuit, identify the section to be retrofitted. Step 2: Disconnect power to the fixture. Step 6: Remove the sockets from the mounting plate as shown in Figure 6. Fig. 2 Step 3: Remove existing linear fluorescent lamps as shown in Fig. 7 Figure 2. Dispose of lamps per local regulations. Step 7: Replace mounting plate making sure that the holes are in the same orientation as when removed. Insert the tab on the mounting plate into the slot in the housing as shown in Figure 7. Gently pry the housing outward with a large flat head screw driver as shown in Figure 8 and insert the tab of the mounting plate into the slot in the housing. Fig. 3 Step 4: Locate the ¼-turn fasteners as shown in Figure 3 and remove the cover panels on both strip light sections and Fig. 8 discard. Note the correct orientation of the holes in the mounting plates in Figure 8. Step 8: Repeat steps 5, 6, and 7 for the remaining 3 socket mount plates. Fig. 4 Step 5: Remove the socket mounting plate by gently prying outward on the housing using a large flathead screwdriver. Figures 4 and 5. Note: For some strip light models the lampholder sockets can be removed without removing the socket mounting plate. See steps 8a - 8c. Fig. 8a Alternate Lampholder Socket Removal Steps: Step 8a: Place your finger behind the lampholder socket as shown in Figure 8a and push the lampholder socket towards the center of the light fixture until the lampholder pops out of the socket mounting plate. Fig. 5 Fig. 8b Step 8b: Push the lampholder socket up and over the lampholder socket mounting plate. See Figures 8b and 8c. Page 2

Step 8c: Repeat steps 8a and 8b for all lampholders. Fig. 8c Fig. 13 Fig. 14 Fig. 9 Step 9: Cut the branch circuit wires at the connection to the fluorescent ballast leads in both strip light housings (if Fig. 15 ballasts exist in both housings) as shown in Figure 9. Step 13: Route blue and red leads through the center of the fuxture as shown in Figure 15. Fig. 10 Step 10: Remove the ballast(s) by removing the mounting screw and dispose of properly per local regulations. See Fig. 16 Figure 10. Step 14: Lift the panel such that the lanyards at each end feed through the holes in which they were inserted, as shown in Figure 16. Step 11: Remove the Linear Retrofit Assembly from the packaging. There are one of two panel assemblies: one with a driver and module and one (LRA28 only) with a module only. For 4 retrofits, skip to Step 16. Fig. 11 Fig. 17 For 8 retrofits locate the panel with the module only. Mount and position this assembly to the fixture section furthest from the branch circuit splice connections with the blue and red leads facing the center of the fixture - See Figure 11. For LRA14 kits go straight to Step 12. Step 15: To use the 1/4 - turn fasteners, first remove the knockout. Secure the panel assembly in place onto the strip light housing, and fasten to the lampholder mounting plates with the ¼-turn fasteners located at each end of the assembly as shown in Figures 17 and 18. For alternate mounting using the drill-point screws provided, see Step 21A. Fig. 12 Step 12: Insert the ends of the lanyards at each end of the panel assembly into the indicated holes as shown in Figures 12 and 13. Allow the assembly to hang by the lanyards as shown in Figure 14. For LRA14 kits skip to Step 19. Fig.18 Page 3

Fig. 19 Step 16: Locate the remaining panel assembly with the driver. Fig. 23 Position the panel assembly for ease of connection to the branch circuit wiring in the fixture as shown in Figure 19. Step 19: Locate the Luminaire Disconnect with the ground wire connected. Secure the ground wire to the equipment grounding conductor in the luminaire or to the luminaire housing in accordance with the National Electrical Code (NFPA 70). See Figure 23. A ground screw is provided with the kit if needed. Fig. 20 Step 17: Insert the ends of the lanyards at each end of the panel assembly into the indicated holes as shown in Figure 20 Fig. 24 as done with the previous panel assembly. Allow the assembly to hang by the lanyards. Step 20: From the branch circuit wires strip about 0.40 inches of insulation. Insert the white branch circuit wire into the white hole of the Luminaire Disconnect and the black wire into the black hole. See Figure 24. Fig. 21 Step 18: Locate the red and blue lead wires with the orange 3-position push-in connectors attached and locate the Fig. 25 red and blue lead wires from the other tandem LRA panel assembly previously installed. Push the blue wire into the connector with the other blue wires and the red wire into the connector with the other red wires as shown in Figures 21 and 22. Step 21: Lift the panel such that the lanyards at each end feed through the holes in which they were inserted as performed with the previous panel assembly as shown in Figure 25. Secure the panel in place using the ¼-turn fasteners at each end of the panel. Fig. 22 Note: Optional 0-10V Analog Dimming Interface Use Violet (+) and Gray (-) for connection to 0-10VDC. Capping Violet and Gray separately provides 100% light output. Wiring Violet and Gray together provides minimum light output. The dimming control connections on the LED driver are for Class 2 wiring methods only. Separate the dimming control field wiring from the branch circuit field wiring in the wiring compartment in accordance with the National Electrical Code. Fig. 26 Alternate Mounting Steps Using Screws: Step 21A: Insert the drill-point screws using a cordless drill with a 1/4 hex driver as shown in Figure 26. Use two screws at each end of the panel. LED MODULE WHITE BLACK LED DRIVER RED BLUE SERRATED HEAD SCREW GROUNDS DRIVER TO HOUSING VIOLET GREY 0-10V DIMMING CONTROL LED MODULE Page 4

DRIVER REPLACEMENT Fig. 26 Step 1: Disconnect the power to the fixture. Fig. 29 Step 2: Locate panel assembly that contains the driver. Open the panel and disconnect the Luminaire Disconnect as shown in Figure 26. Step 3: Remove the panel assembly by taking the installation steps in reverse until the panel assembly is completely removed. LRL MODULE REPLACEMENT Step 1: Disconnect the power to the fixture and locate the panel that contains the LRL module to be replaced. Step 2: Open the panel. If the panel contains the driver then disconnect the luminaire disconnect as shown in Figure 29. Fig. 27 Step 4: Disconnect the blue and red leads from the driver LED output terminals by depressing the button next to the lead as shown in Figure 27. Disconnect the black and white wires from the driver input terminals by depressing the button next to the lead as shown in Figure 28. Fig. 30 Step 5: Remove the driver mounting screw and remove the driver from the panel. Step 6: Install replacement driver in the same orientation as the Fig. 28 one removed. See Figures 27 and 28. Fig. 31 Step 7: Reconnect the red and blue leads to the driver LED output terminals as shown in Figure 27. Reconnect the black and white leads to the driver input terminals as shown in Figure 28. Step 3: Trace the red and blue leads from the LRL module to be replaced to the orange 3-position push-in connectors. Remove the leads from the connectors by turning back and forth and pulling gently until they release. See Figure 30. Step 4: Remove the panel using the reverse of the installation instruction steps. Step 5: Remove the LED LRL module mounting screws. Remove the LED module from the panel cover as shown in Figure 31 by gently pulling the lead wires through the hole in the panel. REPLACEMENT COMPONENTS Step 8: Install the panel into the fixture according to the installation instructions. LRA LED Driver LED Replacement Lamp LRA28-40L8xx-U D10CC55UNVTZCP71C LRL14-30L8xx-750CC00I LRA28-46L8xx-U D10CC55UNVTZ-C10C LRL14-30L8xx-750CC00I LRA28-60L8xx-U D15CC55UNVTZ-C10C LRL14-30L8xx-750CC00I LRA28-84L8xx-U D21CC80UNVTZDP79C LRL14-30L8xx-1050PRMCC00I LRA14-23L8xx-U D700C30UNVTZCP72C LRL14-30L8xx-750CC00I LRA14-30L8xx-U D700C30UNVTZCP93C LRL14-30L8xx-750CC00I LRA14-42L8xx-U D10CC55UNVTZCP86C LRL14-30L8xx-1050PRMCC00I LRA14-60L8xx-U D15CC55UNVTWCP91C LRL14-30L8xx-1050PRMCC00I Where xx = 35 (3500K), 40 (4000K), or 50 (5000K) Fig. 32 LEAD WIRE ROUTING Step 6: Unscrew and remove end cap of new replacement lamp. Carefully pull wires under cap as shown in Figure 32. Replace end cap and secure with screw. Step 7: Install replacement LED LRL module using the reverse of the steps for removal. Install panel assembly back into the fixture according to the installation instructions. Page 5