Automatic Transfer System - ATS

Similar documents
MV Air Insulated Switchgear TAP17. Technical Data TGOOD

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

Benefits, typical uses

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

24kV Medium Voltage Switchgear Metal-Enclosed (LSC2A)

MESG 12 / 17.5 / 24 / 36 KV

HHD HIGH VOLTAGE FUSES GERMAN DIN STANDARD. The temperature limiting function of the fuse striker pin. Design and construction.

This small footprint makes a BIG impact

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction.

CGMCOSMOS Fully gas-insulated modular and compact (RMU) system Up to 24 kv

8DJ. Maintenance-free for lifetime

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

Medium voltage switchgear type W 12. rated voltage 12 kv rated current 630 A

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

NXPLUS C Single busbar. Maintenance-free for lifetime

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

SF6 Load Break Switch 2017 FIL3 - S. Indoor Medium Voltage LBS With or without fuse 12kV- 24kV FIL3 D FIL3. 24KV SF6 Load Break Switch

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

cpg.0 GIS-type medium-voltage switchgear with full insulation in SF 6 gas, up to 40.5 kv in accordance with IEC Standards

ATR-MIX. METAL ENCLOSED SWITCHGEAR kV A ka

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

Vacuum Circuit Breaker

ZX-Family Gas-insulated medium voltage switchgear

Power Xpert UX 36 High-voltage switchgear system. Reliable and safe for high performance applications

Air-insulated medium-voltage secondary distribution switchgear

FUSES. Safety through quality

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

PIX-H Metal-clad switchgear up to 17.5kV

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

DIRECT CONTACT. Switchgear Sales Team TEL : ~9 CHANGWON PLANT Switchgear Design Team TEL : ~9

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

Fixed-Mounted Circuit-Breaker Switchgear Type 8DA and 8DB up to 40.5 kv, Gas-Insulated

ZX2 Gas-insulated medium voltage switchgear

UniSec Operation and maintenance manual

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

Product Specification

EMPAC Metal enclosed capacitor bank for wind applications

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

GE Electrical Distribution. Gerapid High Speed DC Circuit Breakers. On the move. imagination at work

Switchgear Type 8DJH 36 for Secondary

atalog Welcome to ATO.com! Contact us... Tel: (Toll-free) Website:

Electronic Circuit Breaker ESS20

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

MSR01. Water heating controller with solar panel support

Essential Loads also use stand by generator systems mostly in process industries as they relate to high restarting times or high down times.

Electronic Circuit Breaker ESS20-0..

Power systems Protection course

High-voltage high-breaking capacity VV fuse-links

Fixed-Mounted Circuit-Breaker Switchgear Type 8DA and 8DB up to 40.5 kv, Gas-Insulated


SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

1. Safety practices General Introduction Standards...3

Ultra Fast Earthing Switch UFES retrofit Overview

OTPC-SE Service entrance transfer switch open transition

TECHNICAL DESCRIPTION

Medium-Voltage Switchgear OPERATING INSTRUCTIONS

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

Emergency Back-up Power Generation for Water & Wastewater Facilities

Magnetic and Hydraulic-Magnetic Circuit Breaker

OVERVIEW DESCRIPTION AND CHARACTERISTICS APPARATUS AND TYPES AVAILABLE SWITCHGEAR CHARACTERISTICS INSTRUMENT TRANSFORMERS MEASUREMENT SENSORS

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

Xiria the smart solution

Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines

Power Systems PU. HYOSUNG Standard High-voltage Switchgear ProSWGR. Medium Voltage Metal-clad Switchgear

The Key Link for all your Distributions Needs. A Comprehensive Range for All Your Needs

Date Issued: 10 August 2009 Status: ISSUED Review Date: 10 August 2011 Ref: NS5.3 DISTRIBUTED GENERATION TECHNICAL REQUIREMENTS TABLE OF CONTENTS

Air-insulated switchgear UniGear type ZS1

VD4 Installation and service instructions kv A ka

MEDIUM VOLTAGE SWITCHGEAR. DW-2, Primary switchgear, air insulated and metal clad.

High-voltage high-breaking capacity VV fuse-links

INTER PLANT STANDARD STEEL INDUSTRY SPECIFICATION FOR STATIC EXCITATION CONVERTORS FOR SYNCHRONOUS MOTORS (FIRST REVISION)

Medium Voltage Distribution Catalogue Flusarc Make the most of your energy

شركة كهرباء محافظة القدس المساهمة المحدودة

Rex Healthcare Medium Voltage System Presentation APEC 2015 March 15-19, 2015

AutoLink Frequently Asked Questions

Thermal-magnetic Miniature Circuit Breaker 4230-T...

e 2 ALPHA -2S Medium Voltage Double Busbar Switchgear K Catalogue EN

Rated voltage 12 kv to 38.5 kv Rated current 630 A to 2500 A

SIMOVAC and SIMOVAC-AR. Medium-voltage controllers 2.3 kv kv. usa.siemens.com/simovac

Vacuum Generator Circuit Breaker - A trend-setting power plant technology

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

UniGear. Technical Guide

UniSec licensed by ABB, produced by Metix WHERE ENERGY LIVES COMPLETE SOLUTIONS

Vacuum Circuit-Breakers, Type HVX kv, of cassette design, cassette with motor drive

Pretest Module 29 High Voltage Unit 1

The need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where uninterrupted

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

FMX. Power Xpert FMX - IEC Medium Voltage Switchgear. User manual G01 01

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

CPG.0 Single busbar gas-insulated cubicles

Xiria the smart solution

Outdoor vacuum breaker for railway applications - FSK II

TECHNICAL MANUAL AND APPLICATION GUIDE. Engineering Your Power

Transcription:

Annex (B) Automatic Transfer System - ATS Generator ATS change over between 11kv generator and 11Kv Distribution lines Auto SW Mode In the event of a voltage loss in distribution line service (SW) after a time delay T1 the ATS send opening command to SW at same time generator start- up order. The reminding operation of the changeover sequence depending on configuration of generator channel closing option: Case 1 Generator channel closing after Generator power on the Generator channel closing order is sent only when Generator voltage is detected. Case 2 Generator channel closing after generator start- up order. Immediately after sending generator start- up order closing order given to Generator Channel, without waiting until the generator actually started [opening SW,closing SWG ] As soon as voltage returns on the main line (SW) after a time delay T2 the ATS changes back to main line the generator stoppage order is activate [Opining of SWG, closing of SW if the paralleling option is not activate] [Closing of SW, opening of SWG if the paralleling option is activated] 1- Semi - auto SW SWG The ATS does not change back to the main line, except in the event of a voltage loss on the Generator due to the generator stoppage or opening of switch upstream of the SWG

3-Seme Auto SW SWG In the event of a voltage loss in distribution line service (SW) after a time delay T1 the ATS send opening command to SW at same time generator start- up order. The reminding operation of the changeover sequence depending on configuration of generator channel closing option: Case 1 Generator channel closing after Generator power on the Generator channel closing order is sent only when Generator voltage is detected. Case 2 Generator channel closing after generator start- up order. Immediately after sending generator start- up order closing order given to Generator Channel, without waiting until the generator actually started [opening SW,closing SWG ] As soon as voltage returns on the main line (SW) after a time delay T2 the ATS changes back to main line the generator stoppage order is activate [Opining of SWG, closing of SW if the paralleling option is not activate] [Closing of SW, opening of SWG if the paralleling option is activated]

Other functions ATS in ON/OFF mode The ATS system can be switched on or off from the local control panel or remotely (Scada system).when the ATS is OFF, the ATS switches can be electrically actuated by local or remote control (operation in parallel mode is therefore possible). ATS in parallel mode upon Auto return Activating this option enables paralleling of the channels by the automatic transfer system, during the phase of automatic return to the priority channel. To be used when the ATS is in Auto mode. Application: synchronization of the voltages of the main power supply line and the backup line allows return to the main line without any interruption. Generator ON override command Activation of the ATS and transfer on Generator can be activated upon an order: remotely or through dedicated digital input. Applications: Periodic maintenance tests of the ATS/Generator system switch on Generator when the Network is overloaded. During peak hours, and if network is overloaded, Utility can send a remote order that will activate Generator. Having this facility, it will allow a private customer to negotiate better tariff of electricity.

Motorization Switch, circuit breaker Motor mechanism Switch operating mechanism The switch operating mechanism includes a space that is reserved for the installation of a geared motor. This can be installed at the factory, but it can also the installed on-site, by the customer, without de-energizing the unit, and without dismantling the operating mechanism. An electrical interlocking assembly prohibits any false operations. Once motorized, integrates perfectly into a telecontrol system. Earthling switch Closing Hand lever Opening Hand lever Motor option for switch-units and circuit breakers the operating mechanism functions motorized DC power supply (V) 24V Power (W) 240 General operation conditions for indoor switchgears IEC 62271-1 (common specifications for high voltage switchgear and control gear) Ambient temperature: class 25 C indoor lower than or equal to 40 C without de rating lower than or equal to 35 C on 24 hours average without de rating Greater than or equal to 25 C. Altitude: lower than or equal to 1000 m above 1000 m and up to 2000 m with directed field connectors Greater than 2000 m: please consult us for specific precaution. DE-Mt needs voltage de rating after 1 000m. Please consider altitude and temperature when selecting Q function fuses. IEC 62271-200 (A.C. metal enclosed switchgear and control gear for rated voltage Above 1 kv and up to and including 52 kv) Switchgear classification: (metallic partitioning) Loss of service continuity: LSC2B class for circuit breaker and switch (LSC2A for fuse-switch combinations) Internal arc classification: class A-FL up to 20 ka 1 s on request (Access restricted to authorize personnel only, for front and lateral access). Maximum relative humidity: 95%

Main characteristics Unit characteristics