BAPI-Com, Two Wire Multifunction Sensor with Setpoint Slider (BA/BS4SCOM) Temperature/Humidity Sensor

Similar documents
BAPI-Com, Two Wire Multifunction Sensor BA/BS4SCOM Temperature/Humidity Sensor Installation and Operating Instructions

BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint

BAPI-Stat Quantum Temperature Sensor with Display, Button Setpoint, Fan or System Mode Control

BAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series)

BAPI-Stat 3 Room Sensor

CO 2 Room Sensor in the BAPI-Stat Quantum Prime Style Enclosure

CO 2 Room Sensor in the BAPI-Stat 3 Enclosure with Common Ground Configuration

DPS/MPS/RAH/RPS/SWP Space Sensor

VOC Room Sensor in the BAPI-Stat 3 Enclosure with Differential Ground Configuration

Installation and Maintenance Manual IM

Compact Low Pressure Sensor

VOC Duct and Rough Service Sensor

Duct Averaging Transmitters BA/T#-A Temperature Transmitter Installation & Operations

Submersible Averaging Duct Transmitters BA/T#SA Temperature Transmitter Installation & Operations

Digital Room Thermostats with Touch Screen LCD

Low Pressure Sensor. Overview. Specifications. Installation and Operation

Digital Fan Coil Thermostats with 0(2)-10 VDC Fan Output

AD592/592-10K Non-Room Sensors in BAPI-Box, BAPI-Box 2 or BAPI-Box 4 BA/592-x-(BB, BB2, BB4) Temperature Sensor Instructions & Operation

Installation and Operation Instructions DLP Series

Temperature Transmitters

SE8300 Series Installation Guide 24 Vac Low Voltage

Hardware Installation. Tracer AH541 Version 2 Air-Handler Controller CNT-SVN02B-EN

SEN and SEN Outdoor Air Temperature Sensors

GE Measurement & Control

Signet Temperature Transmitter

Figure 1: WPR2 Dimensions and Hardware

INSTALLATION INSTRUCTIONS T-59 SPACE TEMPERATURE SENSOR WITH OVERRIDE & SETPOINT ADJUSTMENT

TS , -850 Series TS , -850 Series TS-57031, TS

Fan Coil Thermostat. Specification & Installation instructions TFC54F3X1. Technical Data

AD592/592-10K Non-Room Units with a Junction Box, Weatherproof (WP) or Weather Tight (EU) Enclosure

Series 1000 Room Temperature Sensors, 1K Ω Platinum (375α) RTD (MBC/RBC/MEC/UC)

Description. functions including single duct pressure dependent or pressure independent systems.

MicroTech III Water Source Heat Pump Wall-Mounted Room Temperature Sensors

SIGNET Temperature Transmitter

SMT-AZC INSTALLATION / OPERATION MANUAL

A419ABG-3C Electronic Temperature Control

Signet Pressure Transmitter

SetPoint 150 Controller Installation Manual

MS Application. Features. Proportional Valve Actuator General Instructions

INSTALLATION INSTRUCTION

TC62D Installation Instructions

Power Switching Devices

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

SetPoint 501 and 501s Controllers Installation and Operation Manual

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Combined Ventilation Controller RVWS-T-224HA

Eco-Propel TM Variable Speed Pump Kit Instruction and Operation Manual, P/N: , Revision 1

SP-32 & SP-32D SP-33, SP-33D SP-34, SP-34D. Description. Specifications. Single Stage Temperature Control

Eco-Propel TM Variable Speed Pump Kit Instruction and Operation Manual, p/n Revision 0

RDG160TU Commercial Thermostat

Signet Pressure Transmitter

Advanced Outdoor Airflow Control, DCV Control and Alarm Solution for OA Applications Document Name: QG_EAC1100_A_R3A

IMC SOLAR EAGLE 2 DIFFERENTIAL TEMPERATURE CONTROLLERS

OE & OE Digital Room Sensor

IMC SOLAR EAGLE 2 DIFFERENTIAL TEMPERATURE CONTROLLERS

SMT-150 Installer Manual

Table of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION...

INSTALLATION INSTRUCTION

USERS MANUAL MCD REMOTE OPERATOR

M9216 Series Electric Spring Return Actuators

User Manual. Solar Charge Controller 3KW

Installation Manual. Mixing Box Control Systems Installation, Operation, and Maintenance Manual. 605 Shiloh Road Plano, Texas

1100 Series Piston Type Differential Pressure Gauges

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

TSMN-90xxx Series TSMN TSMN TSMN Electronic Room Temperature Sensor General Instructions

YCCS TE-6800 Series Temperature Sensors

SLC-811X Series. Single Loop Proportional Temperature Controller General Instructions APPLICATION SPECIFICATIONS

MANUAL TROUBLESHOOTING. ECM Motor. ECM / ECM-DX Series. v100 Issue Date: 08/15/ Price Industries Limited. All rights reserved.

COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2014 Supersedes 8/2012

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

ECONOMIZERS. 5/2012 Supersedes

SE7200 Series Installation Guide

Immersion Temperature Sensors

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Deadband Wireless Pneumatic Thermostat- WPT-800-DB Series

GE Sensing & Inspection Technologies

WIRELESS WALL ADJUSTER INSTALLATION, OPERATION AND MAINTENANCE

PCS 100 SYSTEM INSTALLATION INSTRUCTIONS

MANUAL INSTALLATION. Tracking Controller. TC Series. v100 Issue Date: 02/25/ Price Industries Limited. All rights reserved. Firmware: 1.3.

Instruction Manual. Digital Panel Meter Model 3126 CAUTION. Code Type of T/C Measuring Range Display Range Accuracy

BACnet Lab and Pressurized Room Controllers with Off-board Air Modules

Installation, Operation, and Maintenance Manual CEMLINE CORPORATION

1 Overview. 2 WPT Installation. WPT Installation Manual Document No , Rev 17. Wireless Pneumatic Thermostat- WPT-800 Series

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

Electro Controls. Temperature Controllers WattsIndustries.co.uk

QUICK START GUIDE VAV CONTROLLERS & WALL SENSORS rue Charles, Suite 100, Mirabel, QC, J7J 1X9

ATP-2040 Electric Damper Actuator/Transmitter

Globe Valve Model Description Globe Valve, Hot Water or Steam Applications

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

MiG2 TIME SWITCHES. 1, 2 & 4 Channel, 365 Day, Energy Saving Time Switches

System 350 P352AB Electronic Pressure Control Series

IEC Limit Switches Selection Guide

Heating Cable. Description

ZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators

- Application A Mixing Setpoint Control 153. Mechanical. Electrical 12/08

OpenAir Electric Damper Actuators GBB/GIB Series NSR Rotary 24 Vac - Modulating Control

Aurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 10/14

Blank-off. HVAC unit screws. Spacer for 1" filter ILL. 3. Screw

Transcription:

Product Identification and Overview Power and Communication on Just Two Wires Available with Temperature Sensing, Temperature Setpoint, Optional Occupant Override, Optional Display and Optional %RH Sensing Thermistor, Voltage, Resistance or Dry Contact Outputs Up to 500 Foot Wire Runs Perfect for Existing Wires Many existing buildings have two wire sensors that lack the features customers expect in today s sophisticated systems. The BAPI-Com system uses those existing two wires and offers the owner a full function temperature sensor with temperature setpoint, occupant override, an optional easy-to-read display and optional %RH sensing. The BAPI-Com consists of two modules: the Room Sensor and the Communication Output Module. The Communication Output Module is externally powered and then powers the Room Sensor on two wires. It also communicates with the Room Sensor over those same two power wires to receive the local temperature, humidity, setpoint and override signals as well as powering the display. The Communication Output Module then sends each parameter (temperature, humidity, setpoint and override) to the individual output terminals for the BAS controller to receive and interpret. An Occupied/Unoccupied input is also available on the Communication Output Module to indicate to the Remote Sensor that the control zone is in Occupied or Unoccupied mode for display indication. Note: Not all wires are guaranteed to work. The system has been tested with wires meeting the wire spec of Belden 9841 cable. The units should work to a distance of 500 feet and possibly more on 22AWG to 14AWG wire. Electrical noise is unpredictable but can be limited with wire that is twisted to limit noise imbalance and shielded to limit overall induced noise. If a shield is used, BAPI recommends to only ground the shield at one end to avoid induced ground loop noise. The preferred earth grounding location should be at the Communication Output Module or BAS controller end. Fig 1: BAPI-Com Room Sensor Fig 2: BAPI-Com Communication Output Module Wall Sensor Mounting BAPI recomends mounting to an inside wall away from discharge vents. Avoid baseboard radiation and any sunlit walls. JUNCTION BOX MOUNTING: (Fig. 3) 1. Pull the wire through the wall and out the junction box, leaving about 6 free. 2. Pull the wire through the hole in the base plate. 3. Secure the base to the box using the #6-32x1/2 mounting screws provided. 4. Terminate the unit according to the guidelines in the Termination section. 5. Plug any back box holes or conduit with insulation to avoid wall drafts from affecting the sensor reading. 6. Attach the cover by latching it to the top of the base, rotating the cover down and snapping it into place. Secure the cover by backing out the lock-down screws using a 1/16 Allen wrench until the screws are flush with the cover. Fig 3: Sensor Mounting Mounting hardware is provided for both junction box and drywall installation (junction box installation shown) 1 of 7

Wall Sensor Mounting continued... DRYWALL MOUNTING: 1. Place the base plate against the wall where you want to mount the sensor. 2. Using a pencil to mark out the two mounting holes and the area where the wires will come through the wall. 3. Drill two 3/16 holes in the center of each marked mounting hole. Insert a drywall anchor into each hole. 4. Drill one 1/2 hole in the middle of the marked wiring area. Pull the wire through the wall and out of the 1/2 hole, leaving about 6 free. 5. Pull the wire through the hole in the base plate then secure the base to the drywall anchors using the #6x1 mounting screws provided. 6. Terminate the unit according to the guidelines in the Termination section. 7. Plug any wall holes with insulation to avoid wall drafts from affecting the sensor reading. 8. Attach cover by latching it to the top of the base, rotating the cover down and snapping it into place. Secure the cover by backing out the lock-down screws using a 1/16 Allen wrench until the screws are flush with the cover (see Fig 3). NOTE: In any wall mount application, the mixing of room air and air from within the wall cavity can lead to erroneous readings, condensation and premature failure of the sensor. To prevent this, plug the conduit hole in the junction box with insulation. Communication Output Module Mounting Select an indoor location for the communication module within 500 feet of the sensor and close to the controller so that point wiring is manageable. Blue mounting tabs on the EZ Mount Base are located on top and bottom and can be extended or pushed in by pulling or pushing on the blue tabs for each kind of mounting technique. Blue tabs DIN Rail Mounting: (Fig 4) 1. Pull the blue mounting tabs out. 2. Catch EZ mount hook on DIN rail (shown in Fig 4) and rotate module down until the bottom mounting tab snaps into place on the DIN rail. 3. Connect wires per the Termination Section. 4. To release from the rail, pull both bottom tabs simultaneously. Snaptrack Mounting: (Fig 5) 1. Push the blue mounting tabs in. The edges of the EZ Mount base will fit into the 2.75 snaptrack slots. 2. Connect wires per the Termination Section. Surface Screwed Mounting: (Fig 6) 1. Pull the blue mounting tabs out. 2. Place the EZ unit against the surface and mark the screw holes. 3. Drill 1/8 pilot holes for #6 flathead screws. 4. Screw EZ unit to surface. Note: The mounting holes are elongated to allow for alignment. 5. Connect wires per the Termination Section. Fig 4: DIN Rail Mount Fig 5: Snaptrack Mount Fig 6. Screw Mount Blue tabs 2 of 7

Front Panel Control Descriptions OPTIONAL DISPLAY: The display shows the current temperature unless the setpoint slide is moved, then the display shows the current setpoint for 3 to 4 seconds. The display can also be set up to show only the temperature or only the setpoint. See the Optional Technicians Adjustments section on pg 5. SETPOINT SLIDER: When the setpoint slider is moved enough, the display will show the setpoint and will change the setpoint in 0.1º degree increments across the setpoint range that was specified at the time of the order. (If there is no display, then the user must rely on the side legend to determine the setpoint.) Moving the slider also changes the setpoint output value from the communication output module based on the setpoint output range selected at the time of the order. Sliding upward increases the setpoint and sliding downward decreases the setpoint. (Reverse Acting is field programmable. See the Optional Technicians Adjustments section on pg 5). OPTIONAL OVERRIDE BUTTON FOR DISPLAY UNITS: When the override button is pressed, the BAPI-Man will be displayed as solid (Fig 8) for 3 to 5 seconds and the override output of the communication output module will go to less than 15Ω. (The override signal from the output module can be on the Temperature, Setpoint or Humidity outputs or on a separate Override output depending on how it is ordered.) After pressing the override button, the unit must receive a confirmation closure across the communication output module s Ext. Override Inputs for the BAPI-Man to remain visible on the screen. Pressing the Override button will light the BAPI-Man icon; however, if no confirmation closure is received, then the BAPI-Man will go blank (disappear) after 5 seconds. Sensor Location Typical Engineering Units Override Button Temperature Display in.1 Increments BAPI-Man Occupied or Unoccupied Indicator Setpoint Slider Fig 7: BAPI-Com Room Sensor with Override, Setpoint and Display Solid equals Occupied Hollow equals Unoccupied Fig 8: BAPI-Man Icon Upon receiving a first confirmation closure on the Ext. Override Inputs, the BAPI-Man will show occupied (solid) whenever the closure signal is present and then show unoccupied (hollow) whenever the confirmation signal is removed. The only way to make the BAPI-Man go blank or disappear from the display at this point is to cycle power. OPTIONAL OVERRIDE BUTTON FOR UNITS WITHOUT DISPLAY: When the override button is pressed, the override output on the communication output module will go to less than 15Ω. (The override signal from the output module can be on the Temperature, Setpoint or Humidity outputs or on a separate Override output depending on how the unit is ordered.) Communications Output Module Indicators Green LED Power available Green LED Power available Blue LED Blinks to indicate good communication Red LED Override request Blue LED Blinks to indicate good communication Red LED Override request Fig 9: Communication Output Module Termination with Dedicated Override Output (-J Option) Fig 10: Communication Output Module Termination with Humidity Output 3 of 7

Typical System Termination for BAPI-Com with Override as a Dedicated Output General Wiring Note: All wiring must comply with the National Electric Code (NEC) and local codes. Do NOT run this device s wiring in the same conduit as high or low voltage AC power wiring. BAPI recommends wiring the product with power disconnected. Proper supply voltage, polarity, and wiring connections are important to a successful installation. Not observing these recommendations may damage the product and will void the warranty. BAPI-COM ROOM SENSOR TERMINATION + J1... Power & Communication Out - J1... Power & Communication Out (Purchase 10K-2 Thermistor sensor separately. No polarity) COMMUNICATION OUTPUT MODULE WITH DEDICATED OVERRIDE OUTPUT TERMINATION Terminal Description GND POWER IN... Input Power Common 24 POWER IN... Input Power 24VAC/VDC EXT OVERRIDE INPUT... Override Input Dry Contact to Light the BAPI-Man Icon EXT OVERRIDE INPUT... Override Input Dry Contact to Light the BAPI-Man Icon + POWER OUT... Power & Communication Out to Room Sensor - POWER OUT... Power & Communication Out to Room Sensor (not GND) + TEMP... Temperature Output (0 to 5V, 0 to 10V or resistive value) - TEMP... *Temperature Output (temperature common) + OVR... Independent Override Contact (isolated N.O. contact) - OVR... Independent Override Contact (isolated N.O. contact) + SETPOINT... Setpoint Output (0 to 5V, 0 to 10V or resistive value) - SETPOINT... *Setpoint Output (setpoint common) *In Common Ground (-CG) configuration, - TEMP and - SETPOINT are the same as GND. In Differential Ground (-DF) configuration, - TEMP and - SETPOINT are isolated from GND. Fig 11: BAPI-Com System with Override as a dedicated output 4 of 7

Typical System Termination for BAPI-Com with Humidity as a Dedicated Output General Wiring Note: All wiring must comply with the National Electric Code (NEC) and local codes. Do NOT run this device s wiring in the same conduit as high or low voltage AC power wiring. BAPI recommends wiring the product with power disconnected. Proper supply voltage, polarity, and wiring connections are important to a successful installation. Not observing these recommendations may damage the product and will void the warranty. BAPI-COM ROOM SENSOR TERMINATION + J1... Power & Communication Out - J1... Power & Communication Out (Purchase 10K-2 Thermistor sensor separately. No polarity) COMMUNICATION OUTPUT MODULE WITH DEDICATED OVERRIDE OUTPUT Terminal Description GND POWER IN...Input Power Common 24 POWER IN...Input Power 24VAC/VDC EXT OVERRIDE INPUT...Override Input Dry Contact to Light the BAPI-Man Icon EXT OVERRIDE INPUT...Override Input Dry Contact to Light the BAPI-Man Icon + POWER OUT...Power & Communication Out to Room Sensor - POWER OUT...Power & Communication Out to Room Sensor (not GND) + TEMP...Temperature Output (0 to 5V, 0 to 10V or resistive value) - TEMP...*Temperature Output (temperature common) + HUM...Humidity Output (0 to 5 or 0 to 10 Volts) - HUM...Humidity Output (0 to 5 or 0 to 10 Volts) + SETPOINT...Setpoint Output (0 to 5V, 0 to 10V or resistive value) - SETPOINT...*Setpoint Output (setpoint common) *In Common Ground (-CG) configuration, - TEMP and - SETPOINT are the same as GND. In Differential Ground (-DF) configuration, - TEMP and - SETPOINT are isolated from GND. Fig 12: BAPI-Com System with Humidity as a dedicated output 5 of 7

Optional Technicians Adjustments (The unit is set up in the factory per your order. Adjustments are not required.) The unit is shipped ready to install per the order and does not requires any special setup or programming. The following Setup or Program Menu Changes are available if the installer decides to change the factory settings. The unit must have a display to make these adjustments. ENTERING PROGRAM MODE AND MAKING CHANGES: 1. Remove cover and install the shunt jumper across the J17 pins (see Fig. 13). 2. Use the Up and Down buttons on the back of the circuit board (Fig. 14) to advance to the parameter to adjust. (Moves up or down from page to page or from setting to setting.) 3. Use the Enter button on the back of the circuit board (Fig. 14) to select the menu parameter. This selects the currently displayed menu or selects the new parameter and stores it into memory. You can adjust and quit (remove J17) any time during this procedure. Be sure to press the Enter button to store your selection or it will not be saved. Jumper Off - Run Mode Jumper On - Program Mode Fig 13: J17 Program Jumper PROGRAM MODE MENUS: The Program Mode Menu consists of menu pages P0 through P12 for configuring the sensor. Menu Description P0 ºF or ºC Display: Use the Up/Down buttons to select ºC or ºF. 0 = ºC, 1 = ºF P1 P2 Display Mode: Determines what is displayed on the LCD. 0 - Not used (Do not select) 1 - Temperature Display Only (no setpoint or humidity) 2 - Setpoint Display Only (no temp or humidity) 3 - Temperature and Setpoint Display alternating every 5 seconds (no humidity) 4 - Humidity Display Only (no temperature or setpoint) 5 - Temperature and Humidity Display alternately every 5 seconds (no setpoint) 6 - Setpoint and Humidity Display alternately every 5 seconds (no temperature) 7 - Temperature, Setpoint and Humidity Display alternately every 5 seconds Temperature Offset: Use the Up/Down buttons to change the offset in.1º increments (+10 ºF/ C to -10 ºF/ C maximum) P3 Temperature Max: Use the Up/Down buttons to set the maximum temperature in.1º increments (from +99.9 ºF/ C to -99.9 ºF/ C, span should not exceed 122ºF or 50ºC) P4 P5 P6 Temperature Min: Use the Up/Down buttons to set the minimum temperature in.1º increments (from +99.9 ºF/ C to -99.9 ºF/ C, span should not exceed 122ºF or 50ºC) Setpoint Max: Use the Up/Down buttons to set the max Setpoint temp in.1º increments (from +99.9 ºF/ C to -99.9 ºF/ C) Setpoint Min: Use the Up/Down buttons to set the min Setpoint temp in.1º increments (from +99.9 ºF/ C to -99.9 ºF/ C) P7 Humidity Max: Use the Up/Down buttons to set the max Humidity in.1% increments (from 99.9% to 0%) P8 Humidity Min: Use the Up/Down buttons to set the min Humidity in.1% increments (from 99.9% to 0%) P9 Humidity Offset: Use the Up/Down buttons to change the Humidity offset in.1% increments (from +10% to -10%) P10 P11 P12 Test & Balance: This sets the output of the unit to the maximum and minimum temperature readings 0 - Low Value: Sets the output to the Minimum Temperature (from P4 above) 1 - Normal Value: Sets the output to the Actual Temperature Reading (including the Temperature Offset in P2 above) 2 - High Value: Sets the output to the Maximum Temperature (from P3 above) Note: Leaving page P10 automatically puts the Test & Balance to the Normal mode Sensor Location Indication: Sets the properties of the Location indication on the LCD when the temperature is displayed. 0 - Blank Location Indication: Typically means the sensor is inside the display enclosure. 1 - Inside Location indication: Typically means the sensor is installed away from the sensor display location, possibly in an adjacent clean room or operating room. Requires an External Sensor (-ES option) 2 - Outside Location Indication: Typically means the sensor is installed away from the sensor display location, possibly in an outside air or intake duct or an adjacent room. Requires an External Sensor (-ES option) 3 - Remote Location Indication: Typically means the sensor is installed away from the sensor display location. Requires an External Sensor (-ES option) Reverse Acting: Sets parameter outputs to Reverse Acting (RA) instead of Direct Acting. 0 - All outputs are Direct Acting 1 - Temperature output is Reverse Acting 2 - Setpoint output is Reverse Acting 3 - Temperature and Setpoint outputs are Reverse Acting 4 - Humidity output is Reverse Acting 5 - Temperature and Humidity outputs are Reverse Acting 6 - Setpoint and Humidity outputs are Reverse Acting. 7 - Temperature, Setpoint and Humidity outputs are Reverse Acting Up Down Enter Fig 14: BAPI-Com Setup Buttons (Enter, Up and Down buttons) 6 of 7

Diagnostics Possible Problem No display on the Sensor Possible Solution Check the Room Sensor J1 terminals for 15 to 18VDC Check the voltage on the Communication Output Module Power Out terminals for 18VDC Check the voltage on the Communication Output Module Power In terminals for 20 to 30 VAC/VDC No output on the output module Output module blue led not blinking Check wiring and power. Check connections Specifications ROOM SENSOR Power: 15 to 18VDC, from the Comm. Output Module Wiring: 2 wires, Up to 500ft AWG gauge 22 to 14AWG Twist per foot 5 per ft preferred Shielding Preferred Wire spec typical Belden 9841 External sensor 22 to 18 AWG, TSP, shield grounded, 25 max Temperature Sensor: Thermistor, ±0.36ºF (±0.2ºC) External Sensor: 10K-2 thermistor (Purchased separately) Wired 25 maximum from sensor RH/Temp Sensor: (Communicating Integrated Circuit) Humidity: Capacitive Polymer, ±2% RH (10% to 90%) @25 C, Fully Compensated Temperature: Semiconductor Band Gap, ±0.3 C @ 25 C Communication: Polling system (All messages are confirming) Baud rate 1200 baud Poll Rate 400 ms Type FSK Indication OPT.: LCD, (Temp/Humd/Setpoint/Occupied) Window 2.5 x1.5 Main digit 3.5 digits, 0.6 high, ±99.9 Options: Setpoint Slidepot, Rev. Acting (RA) or Direct Acting (DA) Display Fahrenheit or Celsius Override Pushbutton Test & Balance: Available with display only Adjust Low Temp/Normal/High Temp Material: ABS Plastic, UL94V-0 Ambient: 32º to 122ºF (0º to 50ºC) 0 to 95% RH Non-condensing Agency: RoHS COMMUNICATION OUTPUT MODULE Power in: 20 to 30 VDC/AC, 25mA max 1.7VA @ 30 VAC Terminations: Comm. & PWR Power In Output Override Input Outputs: Volts Contact Resistance Thermistor Input (DI): Indicators: Power Communication Occupied Mounting: DIN Rail Snap Track Screw Mount Material: Ambient: Agency: 2 wires to the sensor, 22-14 AWG 2 wires, 12 to 28 AWG 2 wires per output,12-28 AWG 2 wires, 16 to 30 AWG Three Maximum 0 to 5VDC or 0 to 10VDC, Imax=20mA, DA or RA (Factory Configured only) Reed switch, 0.5A@24VDC 400Ω to 20KΩ span, Vmax=15VDC, DA or RA (Factory Configured only) 10K-2, 10K-3 or 10K-3 [11K] (Factory Configured) External dry contact connection (Closed = Occupied) Green LED (On=Powered) Blue LED, Blinks during normal communication Red LED (On=Occupied request) 3 EZ mount methods 35mm, Quick tab release 4 length, 2.75 wide Four tabs w/0.125 holes ABS Plastic, UL94V-0 32º to 122ºF (0º to 50ºC) 0 to 95% RH Non-condensing RoHS 7 of 7