Operating Instructions for Float Flow Meter / Monitor. Model: SWK

Similar documents
Operating Instructions for Float Flow Meter / Monitor. Model: SWK

Operating Instructions for Polysulfone Paddle Monitor. Model: PPS-..

Operating Instructions for Plastic Flow Meter. Model: KSK

Operating Instructions for Paddle Bellows Flow Monitor. Model: FPS-P...

Operating Instructions for Flow Indicator. Model: DAA

Operating Instructions for Paddle Flowswitch Model: PPS-...

Operating Instruction for Flowmonitor. Model: DF-WM

Operating Instructions for Magnetic Filter. Model: MFR-00

Operating Instructions for Viscosity Compensated Flow Meter / Monitor. Model: VKM

Operating Instructions for Oval Wheel Flowmeter. Model: DOC

Operating Instructions for Torsion Paddle Flow Meter / Monitor. Model: DPT-...

Operating Instruction for Electronic Pressure Switch. Model: PDD

Operating Instructions for Pressure Transmitter with Digital Display. Model: PDA

Operating Instructions for Paddle Flow Monitor. Model: PSR-..., PSE-...

Operating Instructions for Oval Wheel Flowmeter. Model: DOE

KOBOLD VKA FLOWMETER/SWITCH. User Instructions. Manual-VKA_03-04

For industrial applications For marine applications With proximity switch. Piston type flow switches

KOBOLD SV FLOWMETER/SWITCH. User Instructions

Instruction Manual. Ex-Time 40 / 50

Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

OPERATING INSTRUCTIONS

Series TNS/TNF Thermometers Installation/Operation Instructions

Schmidt Mess- und Regeltechnik

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

RESOL SBS 1000 * * Connection Operation

FLOW. control. switch measure. Flow Switches

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

Flow. Oval Wheel Flowmeter Model DOE

HST -LS Interlocking device (Translation of Original Manual)

Differential pressure gauges with Bourdon tube

Installation manual wall-mounted distributor

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Catalyser Introduction. 3. Hazard Information. 2. Area of Application. 3.1 Symbology

Instruction Manual DP03 Plastic paddle-type flow switch with cable

OPERATING INSTRUCTIONS

SEBA HYDROMETRIE, User Manual KLL

Tension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference!

OPERATING INSTRUCTIONS

Declaration of Conformity as per Directive 97/23/EC

Float-operated condensate pump ARI Condensate pump (mechanical) Displacement: 16,5-20 litres. High temperature steel. Stainless steel.

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

KOBOLD KSK FLOWMETER. User Instructions

Exchange of rollers from the XTS-Mover

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

A408 GB. Pneumatic oil and diesel pumps 1:1

Spare parts list Return line filter RFM with 2-hole attachment

Oil-free piston compressors KK and piston vacuum pumps KV

Spare Parts List Return line filter RF

User manual. AGRETO Soil Compaction Tester AGRETO electronics GmbH

Katalysator Nr /

Hand pump PUMP1000-4L-CONTROL. User manual

Operating Data Installation Maintenance Instructions. For Level Sensor. Large Multi-Level

RTD Temperature Sensor omnigrad T -TR 470

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type

Operating manual eviro vibration motors series A12

Brief operating manual for hydraulic power pack type MPN

Operating Instructions for Oval Wheel Flowmeter High pressure. Model: DON-H...R0/H0/Z1/Z2/Z3

Spare Parts List Tank-Top Return Line Filter RFN with Elements to DIN up to 630 l/min, up to 10 bar

PSR/PSE Paddle Flow Monitor for Liquids Switching ranges: L/min water p max : 250 bar, t max

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

ProFlow TO BE REALLY SURE. Vane Meters. Experience in flow measurement. Introduction

Spare Parts List Return Line Filter RFM with 4-hole attachment

Swing Piston Compressors and Vacuum Pumps

Simple float switch TCL001/8181

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

High Precision Turbine Wheel Flow Meter for Liquids

Installation manual portable distributors

Translation of the Original operating instructions Lifting device Z 70 /...

Compressed Air-Supply Meter

Surface-mounting Thermostats Series ATH-SW

KOBOLD DF-MA Flow Transmitter. User Instructions

Braking Devices BR 230/ Assembly- and Commissioning Instructions

KOBOLD DF-WM Flow Monitor. User Instructions

NGS. Dual-Magnet Float Switch. Pressure: up to 25 bar. Density: > 0.7 kg/dm 3. High switch capacity. Material: stainless steel 1.

MAN-P. Diaphragm Pressure Gauges. according to EN for Stringent Demands

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Commissioning & Maintenance Instructions. for. COBRA linear stepping motors

Differential-Pressure Flow Meter

Operating Instructions (Translation)

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Cable thermocouple Model TC40

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

Assembly and operating Instructions Bypass Flow Meter DST

Assembly Instructions

Softstarter SAS SAS 11PUST, 22PUST Assembly- and Commissioning Instructions

Type 6213 EV, 6281 EV

System 6. Solenoid Coils Armature Assemblies Valve Systems

Condensate Drain Valve AK 45. Original Installation Instructions English

DOR. Insertion Paddle Wheel Flowmeter/Monitor. for low viscous liquids. Flow range: ,300 l/s to ,000 l/s. Flow velocity range: 0.

KM-165, KM-185, KM-200 OVERVIEW. Flow Monitor & Flow Indicator. Features. Operation

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

Paddle Flow Monitor Model PSR/PSE

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use!

System 8. Solenoid Coils Armature Assemblies Valve Systems. Nass Controls LP Nass Magnet GmbH Precision Controls Kft.

Magnetic Field Sensor for pneumatic cylinders BIM-UNT-AP6X-0.3-PSG3S/3GD

Operating Instructions

Operating Instructions Garlock Butterfly Valves DN : mm / 2-24

PRO-TYP II. Single and 3-phase Test Adapter with Type 2 Plug for Testing Electric Charging Stations with PROFITEST MTECH+ and MXTRA

Transcription:

Operating Instructions for Float Flow Meter / Monitor Model: SWK

1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5 7. Electrical Connection...5 8. Operation / Configuration / Adjustments...6 8.1. Adjustment of Limit-Value (SWK-1...)...6 8.2. Adjustment of Limit-Value (SWK-2...)...6 9. Technical Information...7 10. Maintenance...7 11. Dimensions...8 12. Declaration of Conformance...9 Manufactured and sold by: Kobold Messring GmbH Nordring 22-24 D-65719 Hofheim Tel.: +49(0)6192-2990 Fax: +49(0)6192-23398 E-Mail: info.de@kobold.com Internet: www.kobold.com page 2 SWK 12/03

2. Note Please read these operating instructions before unpacking and putting the unit into operation. Follow the instructions precisely as described herein. The devices are only to be used, maintained and serviced by persons familiar with these operating instructions and in accordance with local regulations applying to Health & Safety and prevention of accidents. When used in machines, the measuring unit should be used only when the machines fulfil the EWG-machine guidelines. as per PED 97/23/EG In acc. with Article 3 Paragraph (3), "Sound Engineering Practice", of the PED 97/23/EC no CE mark. Diagram 8, Pipe, Group 1 dangerous fluids 3. Instrument Inspection Instruments are inspected before shipping and sent out in perfect condition. Should damage to a device be visible, we recommend a thorough inspection of the delivery packaging. In case of damage, please inform your parcel service / forwarding agent immediately, since they are responsible for damages during transit. Scope of delivery: The standard delivery includes: Float Flow Meter / Monitor Operating Instructions Model: SWK SWK 12/03 page 3

4. Regulation Use These units of type SWK are used with a view to measure and monitor the liquid flow. Only clean, low-viscous and homogeneous liquids may be measured which do not chemically attack the materials used in the construction of these units. An attempt to measure high-viscous liquids may lead to considerable measurement errors. Large dirt-particles can cause the blockage of float and subsequently turn on error indications. Also, ferrite particles, which deposit on float(with embedded magnets), can generate the same effect (we recommend a magnet-filter). These units are configured in the following manner: Housing made of Brass, St. Steel or PVC Screwed reed contact N/O with 1m PVC cable (Brass version) Screwed reed contact N/O with 2m PVC cable (PVC/VA version) Screwed and aligned pointer display (option) 5. Operating Principle KOBOLD Flow Meter/Monitor of type SWK according to the well known float principle, however without making use of generally employed extended measuring tube. Inside a cylindrical lead-pipe a float with aperture moves in the direction of the flow against the recoiling force of a spring. Within the float, a pair of magnets is located which trigger a potential-free protective-gas reed contact. The reed contact is mounted on the exterior of flow-housing and drives a pointer display. This arrangement allows the unit to be operated without consideration to mounting position and keeps the installation measures to a minimum. Flow monitors of type SWK generally find application where small volume flow needs to be measured in a fail-safe manner. page 4 SWK 12/03

6. Mechanical Connection Before installation: Make sure that the permitted max. operating pressure and the operating temperature of the device are not exceeded. Make sure that the electrical supply of the devices corresponds with the operational data of the device. Make sure that no remains of packing material exist within the device. The devices should not be installed within an inductive field. If possible, it should be checked after the mechanical installation whether the connection joints/ piping is properly sealed. Attention! A displacement of switching range occurs if the flow takes place from top to bottom. 7. Electrical Connection Attention! Make sure that the voltage values of your system correspond with the voltage values of the measuring unit, mentioned on type-label. Make sure that the supply wires are de-energized. The connection of bistable reed contact succeeds through the cable on contact housing. The potential-free contact closes on rising level above the adjusted flow value. SWK 12/03 page 5

8. Operation / Configuration / Adjustments The commissioning of these units is prohibited in machines (as long as the guidelines 89/392/EWG remain enforced), which do not comply with these guidelines. The unit is supplied in 'ready for operation' condition. The switching point is adjusted on the lowest scale value. 8.1. Adjustment of Limit-Value (SWK-1...) Loosen the knurled nut on reed contact. Adjust the marking on the contact for the desired value on the scale. In this position the knurled nut should be tightly screwed. 8.2. Adjustment of Limit-Value (SWK-2...) Loosen the knurled nut on reed contact. Connect a suitable continuity-tester on cable ends. Case 1: On an installed unit Open the supply line, and let the flow-medium enter slowly, till the pointer display shows the desired flow value, at which the rising flow should operate the switch(the value for the decreasing flow lies below due to the hysteresis). Case 2: On an upgraded unit the adjustment may be performed by lifting the float with a suitable tool. Switch-housing is dislocated from top to bottom, till the reed contact just closes (electrical continuity). In this position, align the contact by rotating the knurled nut. The unit is now adjusted and ready for operation. On correct adjustment, the limit-value contact performs bistable action. That means, even on crossing the adjusted limit-values, the contact remains closed. Hysteresis Hysteresis is an indication of difference between switch-on and switch-off points of a contact. The average hysteresis corresponds to a float-centre movement of about 3 mm. page 6 SWK 12/03

9. Technical Information Housing/Float: SWK-x1..:Brass (Ni-plated), Ms 58 SWK-x2..: St. Steel, 1.4301 SWK-13..: PVC Connection: G 1/2 female Spring: St. Steel 1.4310 Magnets: Ceramic Stop rings: SWK-x1..: Brass, Ms 58 SWK-x2..: St. Steel, 1.4301 SWK-13..: PVC Max. temperature: SWK-x1.., SWK-x2: 100 C SWK-13..: 60 C Max. pressure: SWK-x1.., SWK-x2: 250 bar SWK-13..: 6 bar Mounting position: Switching point: Switching power: Elect. connection: Switching hysteresis: Repeatability: Weight: arbitrary bistable reed contact N/O on increasing flow max. 230 V AC ; max. 3 A, max. 60 VA/Watt 1 m PVC-cable 3 mm on scale (mean value) < 2.5 % (contact) ± 4% measuring value (display) ~ 350 g Protection cat.: IP 65 10. Maintenance In case the medium to be measured is not contaminated, the device SWK is almost maintenance-free. With lime or such depositions within inner sections the device should be cleaned regularly. Attention! Before the commencement of maintenance work, make sure that the supply wires are de-energized. SWK 12/03 page 7

11. Dimensions G 1/2 22,5 SW 27 22,4 15 90 15 G 1/2 G ½ 0 9 l/min. HO 2 Typ: SWK G ½ 51 Approx. 70 page 8 SWK 12/03

12. Declaration of Conformance We, KOBOLD Messring GmbH, Hofheim-Ts, Germany, declare under our sole responsibility that the product: Float Flow Meter / Monitor Model: SWK... to which this declaration relates is in conformity with the standards noted below: DIN EN 61010-1 1994-03 Safety requirements for electrical equipment for measurement, control and laboratory use IEC529, DIN VDE 0470-1 1992-11 Protection through housing (IP-Code) Also, the following EWG guidelines are satisfied: 73/23 EWG 97/23/EG PED Diagram 8, Pipes, Liquids, Group 1 dangerous fluids Module D, mark CE0098 notified body: Germanischer Lloyd Germany Signed: date: 26.09.03 H. Peters M. Wenzel SWK 12/03 page 9