PHONE: (303) FAX: (970) WEBSITE:

Similar documents
PHONE: (303) FAX: (970) WEBSITE:

PHONE: (303) FAX: (970) WEBSITE:

PHONE: (303) FAX: (970) WEBSITE:

PHONE: (303) FAX: (303) WEBSITE:

S BERGIN R BEATTIE Lighting Engineer. Checked Approved

Test Sample Description Catalog Number: Description:

LED Black Housing High Output Remote Capable

Test Sample Description Catalog Number: Description:

NVLAP LAB CODE:

NVLAP LAB CODE:

Test Sample Description Catalog Number: Description:

Test Sample Description Catalog Number: Description:

Report of Test LLIA

Report of Test LLIA

Report of Test LLIA

Report of Test LLIA

Report of Test LLIA

PHONE: (303) FAX: (970) WEBSITE:

Report of Test LLIA

LEN Series 2x2 / 2x4 LED

Report of Test LLIA

Calibration Due Date Chroma Programmable AC Source 61604

Report of Test LLIA

Report of Test LLIA

Number Eight Lighting Company 803/K2-HI-15-XX/DIM /FS-P-1-WH

Osram Sylvania 200 Ballardvale Street Wilmington, Mass

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

IES INDOOR REPORT PHOTOMETRIC FILENAME : LHB K-U80-UNI.IES. DESCRIPTION INFORMATION (From Photometric File)

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

IES INDOOR REPORT PHOTOMETRIC FILENAME : VW4-LED48DMVSSF50.IES. DESCRIPTION INFORMATION (From Photometric File)

Report of Test LLIA A

Report of Test LLIA A

Report of Test LLIA A

IES INDOOR REPORT PHOTOMETRIC FILENAME : C6R UNVE5-35-LG.IES. DESCRIPTION INFORMATION (From Photometric File)

LIGHT LABORATORY, INC E Kaiser Blvd. Anaheim, CA 92808

IES INDOOR REPORT PHOTOMETRIC FILENAME : 4A_ASD-LVP10M-4N3135-PRM_IES.IES. DESCRIPTION INFORMATION (From Photometric File)

Report of Test LLIA A

Report of Test LLIA A-R02*

Report of Test LLIA

Report of Test LLIA A

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Maxlite Jersey Blvd Rancho Cucamonga, CA 91730

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MaxLite 12 York Ave. West Caldwell, NJ.

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

LLIA A-R02*

Report of Test LLIA

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Calibration Due Date Chroma Programmable AC Source 61604

Report of Test LLIA A

Report of Test LLIA A

Report of Test LLIA A

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

Report of Test LLIA A-R01*

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

LIGHT EFFICIENT DESIGN

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

Report of Test LLIA

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

LIGHT EFFICIENT DESIGN, LLC

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

Report of Test LLIA A

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York AveWest Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report For. Model Different: All construction and rating are the same, except CCT

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

LM Test Report. LIGHT EFFICIENT DESIGN (Brand Name:N/A) LED Luminaire

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: N/A) 12 York Ave, West Caldwell, NJ 07006

NVLAP LAB CODE LM Test Report. For. MaxLite lnc. (Brand Name: MaxLED) 12 York Ave West Caldwell NJ 07006,USA

NVLAP LAB CODE LM Test Report. For. MLS CO., LTD (Brand Name: MLS) NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN, GUANGDONG CHINA

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDUCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

Photometric Test Report. MaxLite Inc 10 York Avenue, West Caldwell, NJ Ramesh Raghavan, x146,

Catalog Number UPC Number Features. General Lumen Output: 2300 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA 92503

Catalog Number UPC Number Features. General Lumen Output: 800 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED)

NVLAP LAB CODE LM Test Report. For SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO.,LTD. (Brand Name: SEPICN LED LIGHTING)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO.,LTD. (Brand Name: SEPICN LED LIGHTING)

Wet Locations Use. RoHS. Model: VAC / 28 W PF LM 93 LM/W. Alluminium + Tempered Glass 24-45VDC 0.

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

Photometric Indoor Test Report

Integrating Sphere Test Report

Integrating Sphere Test Report

2 LED Designer Series

Wet Locations Use VAC / 79 W PF LM 92 LM/W. Alluminium + Tempered Glass 25-42VDC 1.95A 88% CXA PCS

LED Stairwell Fixture

Integrating Sphere Test Report

LED E-Series. we know light. LED Cents LED E-Series troffers gives you the appearance of fluorescent technology with a tube-like glow.

Photometric Test Report. Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase2 Extn. Mohit K Mittal, ,

Transcription:

INDEPENDENT LABORATORIES, INC. REPORT NUMBER: ITL88648-GONIOPHOTOMETRY PAGE: 1 OF 7 CATALOG NUMBER: RP-LUM-48-3500-WHT LUMINAIRE: FABRICATED WHITE PAINTED METAL TOP HOUSING/REFLECTOR, 12 WHITE CIRCUIT BOARDS EACH WITH 18 LEDS, 3-PIECE TRANSLUCENT WHITE CYLINDRICAL DROP DIFFUSER RING. 35" ROUND OPEN CENTER. LAMPS: TWO HUNDRED SIXTEEN WHITE LIGHT EMITTING DIODES (LEDS), VERTICAL BASE-UP POSITION. INPUT ELECTRICAL: 120.0 VOLTS, 72.4 WATTS, 0.604 AMPS MOUNTING: SUSPENDED LED DRIVERS: TWO AC ELECTRONICS AC-40CD1.4APMZ, DRIVERS HAVE MULTIPLE LEADS, ONLY LINE INPUT AND LED OUTPUT LEADS CONNECTED FOR THIS TEST, CLIENT STATES EACH DRIVER PROGRAMMED FOR 400mA OUTPUT. NOTE: DATA SHOWN IS ABSOLUTE FOR THE SAMPLE 47 PROVIDED AT RATED INPUT VOLTAGE (120VAC, 60Hz) TO THE DRIVERS. TEST PROCEDURE: IESNA LM-79-08 TEST DISTANCE = 35.0 FEET DEG CANDELA LUMENS 0 1432 35 5 1432 137 15 1416 400 25 1363 629 35 1271 796 45 1146 885 55 993 888 65 811 802 75 602 634 85 331 373 90 234 95 294 322 105 379 397 115 359 356 500 125 319 286 135 268 208 145 207 131 155 141 66 165 74 22 175 23 3 180 16 1000 ZONAL LUMEN SUMMARY ZONE LUMENS %FIXT 0-30 1166 15.9 0-40 1962 26.7 0-60 3735 50.9 0-90 5544 75.6 90-120 1075 14.7 1500 90-130 1361 18.6 90-150 1700 23.2 0 15 30 90-180 1791 24.4 0-180 7335 100.0 EFFICACY = 101.3 lm/w CIE TYPE - SEMI-DIRECT LUMINAIRE SPACING CRITERION = 1.37 BEAM ANGLE (50%) : 139.3 DEGREES FIELD ANGLE (10%): 309.4 DEGREES Checked Approved M KLOPF N WHITE Lighting Engineer 90 75 60 45

INDEPENDENT LABORATORIES, INC. REPORT NUMBER: ITL88648-GONIOPHOTOMETRY PAGE: 2 OF 7 LUMINANCE DATA IN CANDELA/SQ M ANGLE AVERAGE IN DEG 45 1972. 55 1805. 65 1618. 75 1394. 85 1171.

INDEPENDENT LABORATORIES, INC. REPORT NUMBER: ITL88648-GONIOPHOTOMETRY PAGE: 3 OF 7 CANDELA DISTRIBUTION 0.0 1432 5.0 1432 10.0 1427 15.0 1416 20.0 1395 25.0 1363 30.0 1321 35.0 1271 40.0 1212 45.0 1146 50.0 1072 55.0 993 60.0 906 65.0 811 70.0 709 75.0 602 80.0 485 85.0 331 90.0 234 95.0 294 100.0 364 105.0 379 110.0 373 115.0 359 120.0 341 125.0 319 130.0 295 135.0 268 140.0 239 145.0 207 150.0 175 155.0 141 160.0 107 165.0 74 170.0 44 175.0 23 180.0 16

INDEPENDENT LABORATORIES, INC. REPORT NUMBER: ITL88648-GONIOPHOTOMETRY PAGE: 4 OF 7 5-DEGREE 10-DEGREE ZONAL LUMEN SUMMARY ZONAL LUMEN SUMMARY 0-5 34 0-10 137 5-10 102 0-20 537 10-15 169 0-30 1166 15-20 232 0-40 1962 20-25 289 0-50 2847 25-30 340 0-60 3735 30-35 382 0-70 4537 35-40 414 0-80 5171 40-45 437 0-90 5544 45-50 448 0-100 5866 50-55 449 0-110 6263 55-60 439 0-120 6619 60-65 417 0-130 6905 65-70 385 0-140 7113 70-75 343 0-150 7244 75-80 291 0-160 7310 80-85 222 0-170 7332 85-90 151 0-180 7335 90-95 142 95-100 180 100-105 200 105-110 197 110-115 186 115-120 170 120-125 153 125-130 134 130-135 114 135-140 94 140-145 74 145-150 56 150-155 40 155-160 26 160-165 15 165-170 7 170-175 2 175-180 0

INDEPENDENT LABORATORIES, INC. REPORT NUMBER: ITL88648-GONIOPHOTOMETRY PAGE: 5 OF 7 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20 RC 80 70 50 30 10 0 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 0 113113113113 108108108108 98 98 98 88 88 88 80 80 80 76 1 101 96 91 86 96 91 86 82 82 79 75 74 71 69 67 64 62 59 2 91 82 74 68 86 78 71 65 70 65 60 63 59 55 57 53 50 47 3 82 71 62 55 78 68 60 53 61 55 49 55 50 45 49 45 42 38 4 75 62 53 46 71 59 51 44 54 47 41 48 43 38 44 39 35 32 5 68 55 46 39 65 53 44 38 48 41 35 43 37 33 39 34 30 27 6 63 49 40 34 59 47 39 33 43 36 30 39 33 28 35 30 26 23 7 58 44 36 29 55 42 34 28 39 32 27 35 29 25 32 27 23 20 8 54 40 32 26 51 39 31 25 35 28 23 32 26 22 29 24 20 18 9 50 37 29 23 48 35 28 22 32 26 21 30 24 20 27 22 18 16 10 47 34 26 21 45 32 25 20 30 23 19 27 22 18 25 20 16 15 ALL CANDELA, LUMENS, LUMINANCE, AND VCP VALUES IN THIS REPORT ARE BASED ON ABSOLUTE PHOTOMETRY. THE COEFFICIENT OF UTILIZATION VALUES ARE BASED ON THE TOTAL ABSOLUTE LUMEN OUTPUT OF THIS TEST SAMPLE.

INDEPENDENT LABORATORIES, INC. REPORT NUMBER: ITL88648-GONIOPHOTOMETRY PAGE: 6 OF 7 CONE OF LIGHT DIAGRAM (diameter shown is where fc value is half the fc at nadir) Mounting Height in feet FC Diameter in feet 6.0 39.8 8.2 8.0 22.4 11.0 10.0 14.3 13.7 12.0 9.9 16.5 14.0 7.3 19.2 16.0 5.6 22.0

INDEPENDENT LABORATORIES, INC. REPORT NUMBER: ITL88648-GONIOPHOTOMETRY PAGE: 7 OF 7 ADDRESS: 145 YUMA STREET DENVER, CO 80223 THIS ITL REPORT WITH THE USE OF THE NVLAP LOGO SHALL NOT BE USED BY THE CLIENT TO CLAIM PRODUCT CERTIFICATION, APPROVAL, OR ENDORSEMENT BY NVLAP, NIST, OR ANY AGENCY OF THE FEDERAL GOVERNMENT.