MS300 P latform S cale

Similar documents
Digital Scale. Revision 1.0 August 17, Contents subject to change without notice.

MARINER MODEL WPS12 WATERPROOF DIGITAL PORTION SCALE OWNER S MANUAL

FX 220 User Instructions

MODEL PS-4 DIGITAL PORTION SCALE

8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A USER S MANUAL. Charges & Maintains. Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries

Adam Equipment CPW COMPACT SCALE

SPC Series. Digital Scale. Operation Manual

User Guide. Digital Shipping Scale S150


Price Computing Scale D Series Operation Manual

BatteryChargers. Quick Start Guide AA RECHARGER POWERCHARGER

LED Recessed Troffer Retrofit Kit

Solar Powered Wireless Temperature Station & Sensor

Cab Control Operators Manual

BATTERY CHARGER INSTRUCTION MANUAL. model no. ACG112CL

M1800.

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013)

Bounce & Spin ZebraTM

Compact Scales. Software Revision V1.25 & above

L

Lots of Action in the Jungle!

SolarWrap. Quick Start Guide. Model # PP1040/PP1025

INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1107

L

PerfectTilt RF Motorized Shutter User Manual

Assembled Parts. Terminal Base. Barn Roof. Air Track with Tabs. 2 Barn Walls. Barn Base. 4 Air Tracks with Connectors. Air Track with Support

Valor 2000 Series Instruction Manual

Adam Equipment MIW-20 BABY SCALE. ADAM EQUIPMENT CO. LTD. p.n. 4295, Rev. B, March 2004

4 WAY WIRELESS REMOTE CONTROL SYSTEM. User Manual

USE AND CARE GUIDE 4 FT. LED WRAP LIGHT

Cruising Charger Series OWNER S MANUAL

Instruction Manual. Blink HQ Charger. Charge on. a CarCharging Company

Use and Care Guide.

WIRELESS SMART CHARGING PAD OPERATING INSTRUCTIONS PLEASE READ BEFORE OPERATING THIS EQUIPMENT

Navigator TM Series Balances Instruction Manual

P OWER CUBE PLEASE READ BEFORE OPERATING THIS EQUIPMENT. Powerful Universal Portable Charger T M

V-D2425 and V-D2440 Digital Clock

User Manual Industrial Power Storage System (ips) ips-m Series Battery System

WPS600. Hydraulic Pressure Transducer. User s Guide. 600 bar 60 MPa 8700 psi

(((temporary title page))) Please read these instructions before using your FS/GS HUSKY FS/GS USER LEAFLET

DUAL WIRELESS CHARGING PAD, 10W X 2. Almohadilla de carga inalámbrica doble, 10W X2 USERS GUIDE

SSP-Series Portable Balances Operation Manual

OWNER S MANUAL Please read and understand all precautions prior to use.

Battery Pack Charger OpenStage WL 3 / OpenStage WL3 Plus. Installation Guide A31003-M2000-J

DIGITAL PHYSICIAN Waist-High Scale Models 8430, 8431 & 8437 Operating Instructions

Version /26/09

MONOPRICE. Power Cache 220 Solar Power Generator. User's Manual P/N 15278

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Please read and understand all precautions prior to use.

MULTI-FUNCTION JUMP STARTER

Adam Equipment QT SERIES. ADAM EQUIPMENT CO. LTD. pn Rev. D1, July 2002

LER Electronic Play Mat. Use and Care Guide. Ages. For 1 3 players

NGW & HGW SERIES CONTENTS OPERATION MANUAL CAUTIONS HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE 1. INSTALLATION 2. SPECIFICATIONS

IRRIGATION 810-3T-PLUS TRANSMITTER GUIDE

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

Model WS-6020U Solar Station QUICK SETUP GUIDE

User s Manual. Wave to Me Magic Wand. Years. Disney. Visit DisneyJunior.com VTech Printed in China US F.P.

Touchstone TB130 DC Output UPS

Use and Care Guide. Item #

OVERVIEW OF CONTROLS

Owner's Manual. For latest instructions please go to

Owner's Manual. For latest instructions please go to

Command Center. Model Number Helicopter, Motorcycle, equipment packs and figures sold separately.

Instruction Manual. SmarTire LF Initiator Tool. PN: Revision 1.2. Copyright 2006 SmarTire Systems Inc.

SOKAR FPV DRONE. Quick Start Manual SkyRC Technology Co., Ltd. All Rights Reserved. Version

AC / 65 W M PLEASE READ BEFORE OPERATING THIS EQUIPMENT.

Model 212A Smart SerialPRO Interface User s Guide

HOVERTRAX 2.0 HOVERTRAX DLX 2.0 REPLACEMENT BATTERY PACK KIT

Installer Guide smart connect

Rental Industry Safety Tester Safe Check 5s

Use and Care Guide. Item #

MODEL. TI-500 RF Series. User Manual. Digital Weight Indicator (with wireless weighing capability)

Learning Mower K7165.

Upton LED Chandelier 40in Assembly Instructions

J6666. CalcuBot.

USER S MANUAL G SERIES USER S MANUAL. Ref.49-MG000EN08

AS-RFK2315. User Guide. Two-Way FM LED Remote System. Available functionalities depend on vehicle. Consult your dealer for more information.

MOTION-ACTIVATED WALL LANTERN

SAC SERIES CONTENTS TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS

SFA275 USER MANUAL PLEASE READ THIS USER MANUAL COMPLETELY BEFORE OPERATING THIS UNIT AND RETAIN THIS BOOKLET FOR FUTURE REFERENCE

Owner's Manual. For latest instructions please go to

MQ4C-24/6485 WIRELESS INDOOR/OUTDOOR QUAD-COPTER

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

ROPE LIGHT ITEM # MODEL #UCL48L. Français p. 8. Español p. 15 ATTACH YOUR RECEIPT HERE. Purchase Date

USE AND CARE GUIDE 15 INCH WHITE ROUND FLAT PANEL FIXTURE WITH SELECTABLE COLOR TEMPERATURE

Owner's Manual. mycharge name and logo are registered trademarks of RFA Brands RFA Brands. All Rights Reserved. Patent Pending.

CS-250 Series. CHAIR SCALE SERVICE MANUAL (v1.06d)

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

031266_Umschlag_HV_301.qxd :36 Uhr Seite 1 HV301

OPERATING INSTRUCTIONS

LIGHT & SOUND BATH VANITY LIGHT

Price Computing Scale DS Series Operation Manual

Motion Activated Solar Powered LED Security Light MODEL: PSO1

Smart Sensor Pro+ User Guide

K7116

AS-1271/ AS-1272 AS-1271U/ AS-1272U

CAUTION-ELECTRICALLY OPERATED PRODUCT

Operating Instructions

SWII Users Manual. Intercomp Co County Road 116 Minneapolis, MN (763) Fax

Wireless Thermometer model 00380

Transcription:

3kg x.1kg/66lb x.2lb HOLD UNITS kg/ ON-OFF ZERO TARE T I MS3 MS3 P latform S cale User Instructions E NG L IS H 7613-578 Issue 1 27.4.23

Salter Brecknell Weighing 22. All rights reserved. The information contained herein is the property of Salter Brecknell Weighing and is supplied without liability for errors or omissions. No part may be reproduced or used except as authorised by contract or other written permission. The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodied. MS3 User Instructions

C ontents page no. Dec laration of C onformity S afety Warnings S afe installation 2 2 S afe us e 2 C leaning the machine 2 E MC compliance 3 1 A bout your mac hine 4 1.1 Des cription 4 1.2 Dis play 4 1.3 K ey functions 4 1.4 E rror codes 5 1.5 S pecification 5 2 Weighing 2.1 Hold function 8 3 S etup mode 1 3.1 F unction s etup 1 3.2 C alibration 12 6 4 R S -232 C ommunic ations P rotoc ol 5 P roc edure of F abric ating 5.1 Move 14 15 19 MS3 User Instructions i

Declaration of Conformity Manufacturer Type Salter Brecknell MS3 corresponds to the requirements of the following EC directives: EMC Directive Low Voltage Directive EMC 89/336/EEC LVD 73/23/EEC The applicable harmonized standards are: EN695, EN581 1, EN582 1 A copy of the original signed declaration for this instrument is available from: Salter Brecknell Weighing, P.O. Box 9533, Smethwick, West Midlands, B66 2TE

Electromagnetic Compatibility Statement for North America This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio / TV technician for help. MS3 User Instructions 1

Safety Warnings Safe installation Take care when lifting and transporting heavy objects. Do not overload the machine. Take care not to exceed the weighing capacity of the machine. Pluggable equipment must be installed near an easily accessible socket outlet. Permanently connected equipment must have a readily accessible disconnect device incorporated in the fixed wiring. For your protection all mains (11V or 23V) equipment used out of doors or in wet or damp conditions should be supplied from a correctly fused source and protected by an approved RCD to BS771 or BS7288 or BS4293. The mains lead must be connected to a supply outlet with a protective earth contact. The electrical supply at the socket outlet must provide overcurrent protection of an appropriate rating. IF IN DOUBT SEEK ADVICE FROM A QUALIFIED ELECTRICIAN. Safe use To avoid the possibility of electric shock or damage to the machine, always switch off the machine and isolate from the power supply before carrying out any routine maintenance. Cleaning the machine CAUTION: Harsh abrasives, solvents, scouring cleaners and alkaline cleaning solutions, such as washing soda, should not be used especially on the display windows. Under no circumstances should you attempt to wipe the inside of the machine. MS3 User Instructions 2

The outside of standard products may be wiped down with a clean cloth moistened with water containing a small amount of washing up liquid or disinfectant EMC compliance The following warning may be applicable to your machine. WARNING:This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. 3 MS3 User Instructions

1 About your machine 1 A bout your mac hine 1.1 Des c ription T he MS 3 is a self contained portable platform s cale with a remote dis play. The platform is constructed of mild steel; it has four adjustable feet for levelling. For best results, always install the platform on a hard, flat, level surface. 1.2 Dis play Net Hold Low 888888.8 kg lb oz HOLD UNITS kg/x ON-OFF ZERO TARE T 3 kg x.1kg/66lb x.2lb MS3 S table Minus net t weight Hold weight C entre of zero lb Low Low battery kg weighing mode weighing mode 1.3 K ey func tions ZERO Zero/ON/OF F key. S witches the s cale on or off. TARE T T are key. Applies a tare value MS3 User Instructions 4

1 About your machine UNITS kg/x Units key S elects weighing units HOLD Hold key R etains average weight display. 1.4 E rror c odes E rr E rrl E rre Low Overload B elow zero E E prom error Low battery warning 1.5 S pec ific ation C apacity/res olution Display Operating temperature Weight Dimens ions P latform Dis play head P ower supply R echarge adaptor 3kg x.1kg 66lb x.2lb Height 25mm 7 s egment LC D 5º C to 35º C 25kg 55mm x 55mm x 94 mm 27mm x 9mm x 45mm 6 x 1.2V metal hydride rechargeable batteries 12V AC /15V DC 5 MS3 User Instructions

1 About your machine 1.6 Power supply The indicator head contains six metal hydride re-chargeable batteries. The low battery indicator Low is displayed when the battery power is insufficient to power the scale. Recharging the batteries Insert the AC re-charger adapter into the socket on the base to recharge the batteries. Recharging time is approximately 14 hours. Fully charged batteries should give approximately eight hours of continuous use. CAUTION: Always connect the AC adaptor to the indicator head before connecting to the mains power supply. Disconnect from the mains power supply before disconnecting the adaptor from the indicator head. AC adaptor The Input 12VAC Output 15VDC 3mA recharge adaptor supplied with the MS3 provided MS3 User Instructions 6

2 Weighing 2 Weighing F or best results, always weigh on a hard flat and level surface. The platform has four adjustable feet for leveling. P ress ZE R O to switch on the scale. T he display will show 8888 then go to weighing mode. If the display does not show ZE R O. or press Zero Full Capacity 2% T o s witch off the s cale, pres s and hold ZE R O 1. If necess sary, zero the scale. ZE R O. kg 2. 6 kg 7 MS3 User Instructions

2 Weighing Us ing tares 1. TARE. kg 2. 53 kg TARE T net. kg Weighing units Press UNITS kg/x to toggle between kg, lb, oz. MS3 User Instructions 8

2 Weighing 2.1 Hold f unction T his function enables you to weigh oversized objects that may obscure the dis play. T he system calculates an average weight reading and displays this weight value. T his makes the hold function ideal for weighing individuals that may be moving around on the platform. 1.. kg 2. HOLD. kg 3. Load Weight 1. kg W hen the annunciator stops flashing, the weight is displayed and remains even when the load is removed. 1. kg 9 MS3 User Instructions

2 Weighing 4. To cancel the hold: HOLD. kg MS3 User Instructions 1

3 Setup mode 3 Setup mode 3.1 Function setup In setup mode you can configure the following functions: weighing unit auto shut-off (Battery mode) calibration weight Auto shut-off switches off the scale if no activity is sensed during the period set. The time values are in seconds. To disable auto shut-off, select 2)). Calibration weight allows you to select full load,.5 load or.25 load of the machine capacity for calibration. The table lists the actual weight value you should use. Weighing Full load units 1 / 2 load 1 / 4 load kg 2 kg 1 kg 5 kg lb 5 lb 2 lb 1 lb Calibration weights 11 MS3 User Instructions

3 Set up mode Press TARE 3sec Set Unit A.OFF CAP CAL divs GrAv TrAn Tr End 24 48 96 192 On OFF On 15 3 OFF 6 1 4 1 2 FULL 25kg 3kg 12 18 24 3 OFF kg lb oz On OFF On OFF On OFF On OFF Setup menu Navigating the setup menu TARE 1. Press and hold T till display shows "Set". (approximately three seconds ). TARE 2. Release, T display shows "Unit". 3. Press UNITS kg/x to move across to the option or value you require. 4. Press HOLD to select an option and save. To exit the setup menu and save your changes: Press UNITS kg/x unit you see End. Press mode. HOLD to save your changes and return to weighing MS3 User Instructions 12

3 S etup mode 3.2 C alibration whether you want to use 1 / 2, full or 1 / 4 load for calibration (See Calibration weights on page 11). The example shown in these instructions uses kg weight unit and 1 / 2 load. Save your selection and then switch off the scale. 1. Hold ZE R O At the same time UNIT S kg/x x 3 476 lb Display s hows zero count value. 2. TAR E T lb 13 MS3 User Instructions

3 Setup mode 3. to select alternate units UNITS kg/x lb kg 4. 1kg 7978 kg 5. TARE T cal kg lb oz 1. kg MS3 User Instructions 14

4 RS-232 Communications Protocol 4. RS-232 Communications protocol Type : EIA-RS -232C RS-232 Half-duplex Asynchronous Transmission interface Baud rate : 24/48/96/192 Data Bits : 8 Parity : N Stop bits : 1 D : Weight U: Weight unit Format of Date Communication : 16 Byte, blank communication< 2H> <STX> <Status><+/-><D><D><D><D><D><D><D><U><U><U><U><U> Description of Date Communication : 1. STX : Start of Transmission = 2H 2. +/-: +=(2BH) = Positive Weight, -=(2DH) = Negate Weight 3. DDDDDDD : Value of Weight, 7ASCII Code 4. UUUUU : Weight Units (kg, lb, oz, St ), 5 ASCII Code 5. LF : 7 6. CR : D 7. EXT : Stop of Transmission = 3H For instance : Err : Transmit 16 Byte <Status>="<STX><X>,<E><r><r><2H><2H>... <ETX> 1.2kg : <STX><P><+><2H><1><><><.><2><2H><2H><2H><K><g><ETX> MS3 User Instructions 15

5 P rocedure of F abricating 5. Assembly Procedure for the MS3 1. Screw the four adjustable feet into the holes located on the bottom of the platform. S ee figure 1. F igure 1 2. Screw two vertical stainless steel support rods into the platform opposite each other. See figure 2. F igure 2 MS3 User Instructions 16

HOLD UNITS kg/ ON-OFF ZERO TARE T I 5 P rocedure of F abricating 3. Insert the male plug from the indicator into the remaining stainless steel support rod making sure the male plug exits out the opposite end of the support rod S ee figure 3. Male plug F igure 3 MS3 User Instructions 17

HOLD UNITS kg/ ON-OFF ZERO TARE T I 5 P rocedure of Fabricating F emale plug F igure 4 MS3 User Instructions 18

3kg x.1kg/66lb x.2lb HOLD UNITS kg/ ON-OFF ZERO TARE T I 5 P rocedure of F abricating MS3 F igure 5 MS3 User Instructions 19

5 P rocedure of F abricating about 5 F igure 6 MS3 User Instructions 2

Email: sales@salterbrecknell.co.uk P.O. Box 9533, Smethwick, West Midlands, B66 2TE Tel UK: 87 444 6132 Fax UK: 87 1 2241 Email: sales@salterbrecknell.com