Protector Series ISO FEATURES. Diesel Generator Set INCLUDES:

Similar documents
Protector Series ISO FEATURES. Diesel Generator Set. Protector Series INCLUDES:

Protector Series ISO FEATURES. Standby Generators Liquid-Cooled Gas Engine INCLUDES:

Protector Series ISO. PROTECTOR SERIES Standby Generators Liquid-Cooled Gaseous Engine FEATURES INCLUDES:

Standby Generators ISO FEATURES. Standby Generators Liquid-Cooled Gaseous Engine. Standby Generators INCLUDES:

Protector QS Series ISO. PROTECTOR QS SERIES Standby Generators Liquid-Cooled Gaseous Engine FEATURES INCLUDES:

Protector Series ISO. PROTECTOR SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES INCLUDES:

Protector Series ISO. PROTECTOR SERIES Standby Generators Liquid-Cooled Gaseous Engine FEATURES INCLUDES: Protector Series

Protector QS Series ISO. PROTECTOR QS SERIES Standby Generators Liquid-Cooled Gaseous Engine FEATURES INCLUDES: Protector QS Series

22 kva GENERAC STANDBY GENERATORS ISO. Liquid-Cooled Engine Generator Sets FEATURES INCLUDES:

70 kw GENERAC STANDBY GENERATORS. Liquid-Cooled Engine Generator Sets FEATURES INCLUDES: Standby Power Rating Model QT070 (Bisque) - 70 kw 60Hz

Guardian Series. GUARDIAN SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Guardian Series INCLUDES:

GENERAC GUARDIAN SERIES STANDBY GENERATORS

Centurion Series. CENTURION SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Centurion Series INCLUDES:

GENERAC GUARDIAN SERIES STANDBY GENERATORS

GENERAC QUIETSOURCE SERIES STANDBY GENERATORS

Quietsource Series ISO. QUIETSOURCE SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Quietsource Series INCLUDES:

GENERAC GUARDIAN SERIES STANDBY GENERATORS

GENERAC GUARDIAN SERIES STANDBY GENERATORS

GENERAC GUARDIAN SERIES STANDBY GENERATORS

GENERAC GUARDIAN SERIES STANDBY GENERATORS

GENERAC QUIETSOURCE SERIES STANDBY GENERATORS

22 / 27 / 32 / 38 / 48 kw

STANDBY GENERATOR 25 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

STANDBY GENERATOR 130 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

STANDBY GENERATOR 100 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

STANDBY GENERATOR 80 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

Siemens Liquid Cooled Standby Generators

Standby Generators. 70kW - Liquid Cooled Gas Engine. Meets 2010 EPA emissions regulations.

Siemens Liquid Cooled Standby Generators

STANDBY GENERATORS 17 kw AIR-COOLED GENERATOR SETS

STANDBY GENERATOR 20 kw AIR-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model (Steel - Dark Gray) - 20 kw 60 Hz - US

GENERAC GUARDIAN SERIES STANDBY GENERATORS

7kW. 7kW. CorePower System Residential Standby Generators Air-Cooled Gas Engine FEATURES. Power Rating Model (Composite Polymer) - 7 kw 60Hz

20 kw GENERAC GUARDIAN SERIES STANDBY GENERATORS - PREPACKAGED. Air-Cooled Gas Engine Generator Sets FEATURES

Optimus Residential Standby Generators

16/20/22 kw CENTURION SERIES

17/20kW. 17/20kW. GUARDIAN SERIES Residential Standby Generators Air-Cooled Gas Engine FEATURES. Includes: Standby Power Rating

*Only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes.

GENERAC GUARDIAN SERIES STANDBY GENERATORS

16 kw CENTURION STANDBY GENERATOR. Air-Cooled Gas Engine Generator Sets FEATURES. INCLUDES: True Power Electrical Technology

17 kw GENERAC GUARDIAN SERIES STANDBY GENERATORS - PREPACKAGED. Air-Cooled Gas Engine Generator Sets FEATURES

9/11 kw. 9/11 kw. GUARDIAN SERIES Residential Standby Generators Air-Cooled Gas Engine FEATURES

8/11/13kW. 8/11/13kW. CENTURION SERIES Residential Standby Generators Air-Cooled Gas Engine FEATURES. Includes: Standby Power Rating

1P 120/240V, 3600 RPM,

16 kw CENTURION STANDBY GENERATOR. Air-Cooled Gas Engine Generator Sets FEATURES. Standby Power Rating Model (Steel - Gray) - 16 kw 60Hz

8/11 kw. 8/11 kw. CENTURION SERIES Residential Standby Generators Air-Cooled Gas Engine FEATURES INCLUDES: Standby Power Rating

8/11/14kW. 8/11/14kW. GUARDIAN SERIES Residential Standby Generators Air-Cooled Gas Engine FEATURES. Includes: Standby Power Rating

16/20/22 kw. 16/20/22 kw GUARDIAN SERIES FEATURES. Residential Standby Generators Air-Cooled Gas Engine. Standby Power Rating INCLUDES: 1 of 6

8/11 kw. 8/11 kw. GUARDIAN SERIES Residential Standby Generators Air-Cooled Gas Engine FEATURES

Standby Rated Generators. Standby SG kva / 184 kw. Prime PG kva / 147 kw

QT025A 2.4L 25 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

Power Ratings. Standby SG kva / 160 kw. Prime and standby ratings based on 3-Phase voltages. Model number based on kw rating.

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

Power Ratings. Standby SG kva / 240 kw. Prime PG kva / 192 kw

Standby Rated Generators. Standby SG kva / 28 kw. Prime PG kva / 22 kw

Power Ratings. Standby SG kva / 320 kw. Prime PG kva / 288 kw

Residential Standby Generators

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

Spark-ignited generator set

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

DIESEL GENERATOR SETS

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 20 kw 25 kva 60 Hz

8/10/14kW. 8/10/14kW. GUARDIAN SERIES Residential Standby Generators Air-Cooled Gas Engine FEATURES INCLUDES:

SPECIFICATIONS. Stationary Emergency Generator Specifications STATIONARY EMERGENCY GENERATOR COOLING SYSTEM FUEL SYSTEM ENGINE ELECTRICAL SYSTEM

DIESEL GENERATOR SET. 60 Hz FEATURES

60 Hz FEATURES. Exclusively from your Caterpillar dealer

MDG75DF4 4.5L 75 kva MOBILE DIESEL GENERATOR SET. Power When and Where You Need It

MD L 400 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

Rental Power 800 kw. Specification sheet. Description. Features. Options

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 70 kw 88 kva 60 Hz

SD L 40 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

MG L. MG Series Paralleling Unit. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. MG kw

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 150 kw 188 kva 60 Hz

MDG75DF4 4.5 L 75 kva MOBILE DIESEL GENERATOR SET. Power When and Where You Need It

Spark-ignited generator set

SD L 130 kw INDUSTRIAL DIESEL GENER ATOR SE T EPA Certified Stationary Emergency

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 130 kw 163 kva 60 Hz

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency CODES AND STANDARDS POWERING AHEAD

SG L 300 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

STANDBY 200 ekw 250 kva

SB500/MB500. Industrial Bi-Fuel Diesel Generator Set. 500 kw Bi-Fuel. features. primary codes and standards. Standby Power Rating 500 kw 625 kva 60 Hz

SB600/MB600. Industrial Bi-Fuel Diesel Generator Set. features. primary codes and standards. 600 kw Bi-Fuel. Standby Power Rating 600 kw 750 kva 60 Hz

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency CODES AND STANDARDS POWERING AHEAD

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency POWERING AHEAD CODES AND STANDARDS

MG L. MG Series Paralleling Unit. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. MG kw

SG L 250 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

Diesel generator set QSK23 series engine

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 60 kw 75 kva 60 Hz

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 80 kw 100 kva 60 Hz

STANDBY 200 ekw 250 kva

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

Power Connect TM Series RX60

RENTAL DIESEL GENERATOR SET

Diesel generator set QSX15 series engine

STANDBY 80 ekw 100 kva PRIME 72 ekw 90 kva

Power Connect RX50. Series. Specification sheet. Features and benefits. Weight, size and sound level

Diesel generator set QSX15 series engine

G50U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

Diesel generator set QSK23 series engine

MDG100DF4CAN 4.5 L 100 kva MOBILE DIESEL GENERATOR SET. Codes and Standards Generac Mobile products are designed to the following standards:

Transcription:

Protector Series Diesel Generator Set Protector Series 1 of 6 INCLUDES: Two Line LCD Multilingual Digital Evolution Controller (English/Spanish/French/ Portuguese) with external viewing window for easy indication of generator status and breaker position. Isochronous Electronic Governor Sound Attenuated Aluminum Enclosure Smart Battery Charger UV/Ozone Resistant Hoses ±1% Voltage Regulation Integrated Base Tank Provides Up to 50 Hours of Run Time 3 Year Limited Warranty Not for sale in US/CA Standby Power Rating Model RD015-15 kw 60 Hz Model RD020-20 kw 60 Hz Model RD030-30 kw 60 Hz Model RD048-48 kw 60 Hz (single phase only) Model RD050-50 kw 60 Hz (three phase only) *Built in the USA using domestic and foreign parts FEATURES INNOVATIVE DESIGN & PROTOE TESTING are key components of GENERAC S success in IMPROVING POWER BY DESIGN. But it doesn t stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance. TEST CRITERIA: 3 PROTOE TESTED 3 NEMA MG1-22 EVALUATION 3 SYSTEM TORSIONAL TESTED 3 MOTOR STARTING ABILITY SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine. Digital voltage regulation at ±1%. SINGLE SOURCE SERVICE RESPONSE from Generac s extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. GENERAC TRANSFER SWITCHES. Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. ISO 9001: 2008

Protector Series 2 of 6 15 20 30 48 50 kw application & engineering data GENERATOR SPECIFICATIONS Type Synchronous Rotor Insulation Class H (15 & 20 kw) or F (30, 48 & 50 kw) Stator Insulation Class H Telephone Interference Factor (TIF) <50 Alternator Output Leads 1-Phase 3 wire Alternator Output Leads 3-Phase 6 wire Bearings Single Sealed Cartridge Coupling Direct, Flexible Disc Excitation System Direct VOLTAGE REGULATION Type Electronic Sensing Single Phase Regulation ± 1% Features Adjustable Voltage & Gain GOVERNOR SPECIFICATIONS Type Electronic Isochronous Steady State Regulation ± 0.25% ELECTRICAL SYSTEM Battery Charge Alternator Static Battery Charger Recommended Battery (battery not included) System Voltage 50 Amp (15 & 20 kw) or 70 Amp (30, 48 & 50 kw) 2 Amp Group 27F, 700 CCA 12 Volts GENERATOR FEATURES Revolving field heavy duty generator Directly connected to the engine Operating temperature rise 120 C above a 40 C ambient Class H insulation is NEMA rated Class F insulation is NEMA rated All models fully prototype tested ENCLOSURE FEATURES Aluminum weather protective enclosure Enclosed critical grade muffler Small, compact, attractive SAE Ensures protection against mother nature. Electrostatically applied textured epoxy paint for added durability. Quiet, critical grade muffler is mounted inside the unit to prevent injuries and maximize sound dampening. Makes for an easy, eye appealing installation. Sound attenuated enclosure ensures quiet operation.

15 20 30 48 50 kw application & engineering data ENGINE SPECIFICATIONS: 15 & 20 kw Make Model Cylinders 4 Generac In-line Displacement (Liters) 2.28 Bore (in/mm) 3.46/88 Stroke (in/mm) 3.70/94 Compression Ratio 21.3:1 Intake Air System Cylinder Head Type Piston Type ENGINE SPECIFICATIONS: 30 kw Make Model Cylinders 4 Naturally Aspirated Cast Iron OHV Aluminum Generac In-line Displacement (Liters) 2.4 Bore (in/mm) 3.54/90 Stroke (in/mm) 3.70/94 Compression Ratio 21.3:1 Intake Air System Cylinder Head Type Piston Type ENGINE SPECIFICATIONS: 48/50 kw Make Model Cylinders 4 Displacement (Liters) 3.4 Turbocharged Cast Iron OHV Aluminum Generac In-Line Bore in/mm 3.86/98 Stroke in/mm 4.45/113 Compression Ratio 18.5:1 Intake Air System Cylinder Head Type Piston Type Turbocharged/Aftercooled Cast Iron OHV Aluminum ENGINE LUBRICATION SYSTEM Oil Pump Type Oil Filter Type Crankcase Capacity (quarts/liters) ENGINE COOLING SYSTEM Type Water Pump Fan Speed (rpm) Fan Diameter (in/mm) Fan Mode FUEL SYSTEM Fuel Type Fuel Pump Type Injector Type Fuel Supply Line (mm/in) Fuel Return Line (mm/in) Fuel Specification Fuel Filtering (microns) TANK SPECIFICATIONS Total Size (gallons/liters) Usable Size (gallons/liters) Run Time @ 1/2 Load (hrs) Gear Full flow spin-on canister 6.87/6.5-15 & 20 kw 6.8/6.4-30 kw 7.4/7-48 & 50 kw Pressurized radiator -15 & 20 kw Closed recovery - 30, 48 & 50 kw Pre-lubed, self-seating 1800-15 & 20 kw 2061-30 kw 2029-48 & 50 kw 18.11/460 (15 & 20 kw) 22/559 (30, 48 & 50 kw) Pusher Ultra Low Sulfur Diesel Fuel Mechanical Engine Driven Gear Mechanical 7.94/0.31 (ID) 7.94/0.31(ID) ASTM 5-15, 20 & 30 kw 10-48 & 50 kw 45/170.3-15 & 20 kw 68/257.4-30, 48 & 50 kw 40/151.4-15 & 20 kw 61/230.9-30, 48 & 50 kw 50.6-15 kw 38.1-20 kw 40.7-30 kw 26.5-48 & 50 kw Protector Series 3 of 6 WEIGHTS AND DIMENSIONS 15 kw 20 kw 30 kw 48 kw 50 kw Weight (lb/kg) 1224/555 1689/766 1953/886 Dimensions (LxWxH) (in/cm) 62 x 31 x 49/158 x 78 x 124 77 x 35 x 55/195 x 89 x 141

Protector Series 4 of 6 15 20 30 48 50 kw operating data GENERATOR OUTPUT VOLTAGE/kW - 60 Hz RD015 RD020 RD030 RD048 & RD050 kw (Standby) Amp (Standby) kw (Prime) Amp (Prime) CB Size 120/240 V, 1Ø, 1.0 pf 15 62 12 50 70 120/208 V, 3Ø, 0.8 pf 15 52 12 42 60 120/240 V, 3Ø, 0.8 pf 15 45 12 36 50 120/240 V, 1Ø, 1.0 pf 20 83 16 67 100 120/208 V, 3Ø, 0.8 pf 20 69 16 56 80 120/240 V, 3Ø, 0.8 pf 20 60 16 48 70 120/240 V, 1Ø, 1.0 pf 30 125 24 100 150 120/208 V, 3Ø, 0.8 pf 30 104 24 83 125 120/240 V, 3Ø, 0.8 pf 30 90 24 72 100 277/480 V, 3Ø, 0.8 pf 30 45 24 36 50 120/240 V, 1Ø, 1.0 pf 48 200 38.4 183 200 120/208 V, 3Ø, 0.8 pf 50 173 40 153 200 120/240 V, 3Ø, 0.8 pf 50 150 40 132 175 277/480 V, 3Ø, 0.8 pf 50 75 40 66 90 SURGE CAPACITY IN AMPS RD015 RD020 RD030 RD048 & RD050 Voltage Dip @ <.4 pf 15% 30% 120/240 V, 1Ø 53 129 120/208 V, 3Ø 37 90 120/240 V, 3Ø 32 78 120/240 V, 1Ø 87 211 120/208 V, 3Ø 59 143 120/240 V, 3Ø 51 124 120/240 V, 1Ø 66 168 120/208 V, 3Ø 59 144 120/240 V, 3Ø 51 125 277/480 V, 3Ø 26 64 120/240 V, 1Ø 69 189 120/208 V, 3Ø 90 218 120/240 V, 3Ø 78 189 277/480 V, 3Ø 36 87 ENGINE FUEL CONSUMPTION RD015 RD020 RD030 RD048 & RD050 gal/hr L/hr 25% of rated load 0.51 1.93 50% of rated load 0.79 2.99 75% of rated load 1.14 4.31 100% of rated load 1.48 5.58 25% of rated load 0.67 2.6 50% of rated load 1.05 3.97 75% of rated load 1.52 5.32 100% of rated load 1.98 7.48 25% of rated load 0.92 3.5 50% of rated load 1.45 5.5 75% of rated load 1.96 7.4 100% of rated load 2.74 10.4 25% of rated load 1.35 5.11 50% of rated load 2.15 8.14 75% of rated load 3.06 11.58 100% of rated load 3.98 15.07 STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice.

15 20 30 48 50 kw operating data ENGINE COOLING 15 kw 20 kw 30 kw 48 & 50 kw Air flow (inlet air including alternator and combustion air in cfm/cmm) 2824/80 2824/80 3038/86 2824/80 System coolant capacity (gal/liters) 2.8/10.6 2.8/10.6 2.8/10.6 2.8/10.6 Heat rejection to coolant (BTU per hr/mj per hr) 63,535/67 63,535/67 111,000/117.1 135,900/143.4 Maximum operation air temperature on radiator ( C/ F) 50/122 Maximum ambient temperature ( C/ F) 50/122 Protector Series 5 of 6 COMBUSTION REQUIREMENTS Flow at rated power (cfm/cmm) 84.76/2.4 84.76/2.4 90/2.55 190/5.38 SOUND EMISSIONS Sound output in db(a) at 23 ft (7 m) with generator in exercise mode* 65 Sound output in db(a) at 23 ft (7 m) with generator operating at normal load* 70 *Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters. EXHAUST Exhaust flow at rated output (cfm/cmm) 98.88/2.8 98.88/2.8 230/6.51 448/12.7 Exhaust temperature at rated output ( C/ F) 510/950 510/950 454.4/850 604.4/1120 ENGINE PARAMETERS Rated Synchronous RPM 1800 HP at rated kw 26.4 33.5 49 85 POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Deration...3% for every 5 C above 25 C or 1.7% for every 5 F above 77 F Altitude Deration (15, 30, 48 & 50 kw)...1% for every 100 m above 915 m or 3% for every 1000 ft above 3000 ft Altitude Deration (20 kw)... 1% for every 100 m above 305 m or 3% for every 1000 ft above 1000 ft CONTROLLER FEATURES 2-Line Plain Text Multilingual LCD Display...Simple user interface for ease of operation. Mode Buttons: Auto... Automatic Start on Utility failure. Programmable 7 day exerciser. Manual... Start with starter control, unit stays on. If utility fails, transfer to load takes place. Off...Stops unit. Power is removed. Control and charger still operate. Ready to Run/Maintenance Messages... Standard Engine Run Hours Indication... Standard Programmable start delay between 2-1500 seconds...standard (programmable by dealer only) Utility Voltage Loss/Return to Utility Adjustable... From 140-171 V/190-216 V Future Set Capable Exerciser/Exercise Set Error Warning... Standard Run/Alarm/Maintenance Logs... 50 Events Each Engine Start Sequence... Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration). Starter Lock-out...Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger... Standard Charger Fault/Missing AC Warning... Standard Low Battery/Battery Problem Protection and Battery Condition Indication... Standard Automatic Voltage Regulation with Over and Under Voltage Protection... Standard Under-Frequency/Overload/Stepper Overcurrent Protection... Standard Safety Fused/Fuse Problem Protection... Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown... Standard Overcrank/Overspeed (@ 72 Hz)/RPM Sense Loss Shutdown... Standard High Engine Temperature Shutdown... Standard Internal Fault/Incorrect Wiring Protection... Standard Common External Fault Capability... Standard Field Upgradable Firmware... Standard

Protector Series 6 of 6 15 & 20 kw installation layout Drawing #0K7394-A (1 of 2) NOTES: WEIGHT DATA WITH EMPTY BASETANK (SEE NOTE 5) 1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1092 (43") WIDE X 1887 (74.3") LONG. REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES. 2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL, STATE, AND LOCAL CODES. 3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION: - SEE SPECIFICATION SHEET OR OWNERS MANUAL - ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR. 4. REMOVE THE REAR STUB-UP AND REAR ENCLOSURE COVER PANEL TO ACCESS THE STUB-UP AREAS AS FOLLOWS: - HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION, NEUTRAL CONNECTION, AND BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION. - LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES AND ACCESSORY RELAY CONNECTION (QTY 4) 5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. 6. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND RECIRCULATION OF AND/OR IMPROPER COOLING AIR FLOW. 7. EXHAUST SYSTEM MAXIMUM BACK PRESSURE: 24 INCHES H2O. 8. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS. 9. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 5/8-11 GRADE 5 (USE STANDARD SAE TORQUE SPECS) 10. MUST ALLOW FREE FLOW OF INTAKE AIR, AND EXHAUST. SEE SPEC SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS. 11. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE AND THAT FROM RADIATOR IS NOT RECIRCULATED. GENERATOR AS SHOWN 555 [1224] WITH WODDEN SHIPPING SKID 594 [1310] 735 [28.9] CENTER OF GRAVITY (SEE NOTE 5) 3 1236 [48.7] OVERALL HEIGHT 776 [30.6] OVERALL VIEW 303 [11.9] 1065 [41.9] 182 [7.2] 1582 [62.3] OVERALL LENGTH 110 [4.3] 212 [8.3] 630 [24.8] DOOR SERVICE ITEM 2.3L OIL FILL CAP RIGHT SIDE OIL DIP STICK RIGHT SIDE OIL FILTER RIGHT SIDE OIL DRAIN HOSE RIGHT SIDE RADIATOR DRAIN HOSE LEFT SIDE COOLANT RECOVERY BOTTLE LEFT SIDE RADIATOR FILL CAP ACCESS ROOF TOP AIR CLEANER ELEMENT EITHER SIDE MUFFLER FRONT FAN BELT EITHER SIDE BATTERY LEFT SIDE WEIGHT: KG [LBS] DIMENSIONS: MM [INCH] VISE ACTION LATCH, ONE PER DOOR, ONE LIFT-OFF DOOR PER SIDE OF GENERATOR. REAR ENCLOSURE COVER PANEL CIRCUIT BREAKER SEE NOTE 3 CUSTOMER ACCESS ASSEMBLY, CONTROL PANEL ACCESS, BATTERY CHARGER LOCATED WITHIN REMOVABLE STUB-UP COVER REFERENCE OWNERS MANUAL FOR PERIODIC REPLACEMENT PART LISTINGS. LEFT SIDE VIEW RIGHT SIDE VIEW LIFTING PROVISION (4 PLACES) SEE NOTES 5, 8 AND CENTER OF GRAVITY DIMENSIONS 2" O.D. EXHAUST OUTLET REMOVE COVER FOR ACCESS TO RADIATOR FILL CAP (BOTH SIDES) TOP VIEW EXHAUST MUFFLER ENCLOSED WITHIN GENERATOR ENCLOSURE REAR VIEW AIR INTAKE (BOTH SIDES) BATTERY 12 VOLT NEGATIVE GROUND ENCLOSURE PANEL MUST BE REMOVED TO FACILITATE BATTERY INSTALLATION AND REMOVAL

15 & 20 kw installation layout REMOVABLE STUB-UP COVER SEE SHEET 4 ON SHEET 1 OF 2 16.66 [.66] MOUNTING HOLES 6X Drawing #0K7394-A (2 of 2) 7 of 6 625 [24.6] 112 [4.4] 445 [17.5] 851 [33.5] 786 [31.0] 695 [27.4] 1120 [44.1] 1007 [39.7] FUEL RETURN FUEL FILL FUEL LEVEL GAUGE/SENDER FUEL SUPPLY EMERGENCY VENT HIGH AND LOW VOLTAGE STUB-UP AREA CIRCUIT BREAKER NEUTRAL AND CUSTOMER CONNECTION OPENING 105 [4.1] 19 [.7] 100 [3.9] 51 [2.0] 9 [.4] 1368 [53.9] 169 [6.7] TOP VIEW STUB-UP AREA 251 [9.9] FUEL TANK HT. 792 [31.2] 1472 [57.9] 1582 [62.3] LEFT SIDE VIEW 674 [26.5] STUB-UP AREA 354 [13.9] 19 [.7] FUEL TANK TOTAL CAPACITY 169 [44] USABLE CAPACITY 151 [40] CAPACITY: LITER [GALLON] DIMENSIONS: MM [INCH] 738 [29.1] 739 [29.1] MOUNTING CENTERS 776 [30.6] REAR VIEW NORMAL VENT Protector Series

Protector Series 8 of 6 30 kw installation layout Drawing #0K7002A-B (1 of 2) 173 [6.8] 146 [5.8] 3 302 [11.9] 1322 [52.0] 182 [7.2] 1954 [76.9] OVERALL LENGTH 1407 [55.4] OVERALL HEIGHT 888 [35.0] OVERALL WIDTH 843 [33.2] CENTER OF GRAVITY (BOTH SIDES) 758 [29.8] DOOR SERVICE ITEM 2.4L OIL FILL CAP RIGHT SIDE OIL DIP STICK RIGHT SIDE OIL FILTER RIGHT SIDE OIL DRAIN HOSE RIGHT SIDE RADIATOR DRAIN HOSE LEFT SIDE AIR CLEANER ELEMENT LEFT SIDE MUFFLER FRONT FAN BELT EITHER SIDE BATTERY LEFT SIDE WEIGHT DATA WITH EMPTY BASETANK (SEE NOTE 5) GENERATOR AS SHOWN 766 [1689] WITH WOODEN SHIPPING SKID 802 [1769] NOTES: 1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1194 (47") WIDE X 2261 (89") LONG. REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES 2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL, STATE, AND LOCAL CODES. 3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION: - SEE SPECIFICATION SHEET OR OWNERS MANUAL - ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR 4. REMOVE THE REAR TANK AND REAR ENCLOSURE COVER PANEL TO ACCESS THE STUB-UP AREAS AS FOLLOWS: - HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION. - LOW VOLTAGE CONNECTIONS INCLUDING TRANSFER SWITCH CONTROL WIRES 5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. 6. ENGINE SERVICE CONNECTIONS OIL DRAIN: 3/8" NPT EXHAUST OUTLET: 2" O.D. 7. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND AND RECIRCULATION OF AND/OR IMPROPER COOLING AIR FLOW. 8. EXHAUST SYSTEM MAXIMUM BACK PRESSURE: 35 INCHES H2O. 9. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS. 10. MOUNTING BOLTS OR STUDS TO CONCRETE PAD SHALL BE 5/8-11 GRADE 5 (USE STANDARD SAE TORQUE SPECS) REFERENCE OWNERS MANUAL FOR PERIODIC REPLACEMENT PART LISTINGS. RIGHT SIDE VIEW REAR VIEW REMOVE COVER FOR ACCESS TO RADIATOR FILL CAP EXHAUST MUFFLER ENCLOSED WITHIN GENERATOR ENCLOSURE LEFT SIDE VIEW REAR ENCLOSURE COVER PANEL CIRCUIT BREAKER SEE NOTE 3 CUSTOMER ACCESS ASSEMBLY, CONTROL PANEL ACCESS, BATTERY CHARGER LOCATED WITHIN REAR TANK COVER VISE ACTION LATCH, ONE PER DOOR, ONE LIFT-OFF DOOR PER SIDE OF GENERATOR LIFTING PROVISIONS (4 PLACES) SEE NOTE 9 AND CENTER OF GRAVITY DIMENSIONS AIR INTAKE (BOTH SIDES) TOP VIEW BATTERY 12 VOLT NEGATIVE GROUND

30 kw installation layout Protector Series 9 of 6 FUEL TANK TOTAL CAPACITY 253.6 [67] USABLE CAPACITY 230.9 [61] CAPACITY: LITER [GALLONS] DIMENSIONS: MM [INCH] 757 [29.8] 621 [24.5] 267 [10.5] 181 [7.1] REMOVABLE COVER 112 [4.4] 1194 [47.0] 1044 [41.1] FUEL SUPPLY FUEL RETURN 828 [32.6] 923 [36.4] 1429 [56.2] 1554 [61.2] 1764 [69.4] 712 [28.0] 1242 [48.9] 1842 [72.5] FUEL FILL FUEL LEVEL GAUGE/SENDER 112 [4.4] 125 [4.9] 38 [1.5] 187 [7.3] STUB-UP AREA 353 [13.9] 19 [.7] 786 [30.9] STUB-UP AREA 51 [2.0] 851 [33.5] 888 [35.0] 16.7 [.66] MOUNTING HOLES (8 PLACES) INNER TANK NORMAL VENT INNER TANK EMERGENCY VENT HIGH AND LOW VOLTAGE STUB-UP AREA CIRCUIT BREAKER, NEUTRAL AND CUSTOMER CONNECTION OPENING REMOVABLE STUB-UP COVER Drawing #0K7002A-B (2 of 2)

Protector Series 10 of 6 48 & 50 kw installation layout Drawing #0K6968A-A (1 of 2) 3 NOTES: WEIGHT DATA WITH EMPTY BASETANK (SEE NOTE 5) 1408 [55.4] OVERALL HEIGHT 302 [11.9] 1954 [76.9] OVERALL LENGTH 182 [7.2] 888 [35.0] OVERALL WIDTH (BOTH SIDES) REMOVE COVER FOR ACCESS TO RADIATOR FILL CAP 892 [35.1] CENTER OF GRAVITY SEE NOTE 5 173 [6.8] 146 [5.8] 758 [29.8] DOOR FRONT TANK COVER 1322 [52.0] EXHAUST MUFFLER ENCLOSED WITHIN GENERATOR ENCLOSURE SERVICE ITEM 3.4L OIL FILL CAP RIGHT SIDE 1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1194 (47") WIDE X 2261 (89") LONG. REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES 2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL, STATE AND LOCAL CODES. 3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION: - SEE SPECIFICATION SHEET OR OWNERS MANUEL - ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR 4. REMOVE THE REAR TANK AND REAR ENCLOSURE COVER PANEL TO ACCESS THE STUB-UP AREAS AS FOLLOWS: -HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION. -LOW VOLTAGE CONNECTIONS INCLUDE TRANSFER SWITCH CONTROL WIRES 5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. 6. ENGINE SERVICE CONNECTIONS OIL DRAIN: 3/8" NPT EXHAUST OUTLET: 2" O.D. 7. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND RECIRCULATION OF AND/OR IMPROPER COOLING AIR FLOW. 8. EXHAUST SYSTEM MAXIMUM BACK PRESSURE: 35 INCHES H20. 9. REFERNCE OWNERS MANUAL FOR LIFTING WARNINGS. 10. MOUNTING BOLTS OR STUDS TO CONCRETE PAD SHALL BE 5/8-11 GRADE 5 GENERATOR AS SHOWN (STEEL ENCL) 886 [1953] OIL DIP STICK RIGHT SIDE WITH WOODEN SHIPPING SKID 925 [2039] OIL FILTER RIGHT SIDE OIL DRAIN HOSE RIGHT SIDE RADIATOR DRAIN HOSE LEFT SIDE AIR CLEANER ELEMENT RIGHT SIDE MUFFLER FRONT FAN BELT EITHER SIDE BATTERY LEFT SIDE REFERENCE OWNERS MANUAL FOR PERIODIC REPLACEMENT PART LISTINGS. TOP VIEW UNITS: WEIGHT - KG [LBS] DIMENSION - MM [INCH] VISE ACTION LATCH, ONE PER DOOR, ONE LIFT-OFF DOOR PER SIDE OF GENERATOR REAR ENCLOSURE COVER PANEL RIGHT SIDE VIEW REAR VIEW LEFT SIDE VIEW REAR TANK COVER CIRCUIT BREAKER SEE NOTE 3 LIFTING PROVISIONS (4 PLACES) SEE NOTE 10 AND CENTER OF GRAVITY DIMENSIONS CUSTOMER ACCESS ASSEMBLY, CONTROL PANEL ACCESS, BATTERY CHARGER LOCATED WITHIN AIR INTAKE (BOTH SIDES) BATTERY 12 VOLT NEGATIVE GROUND

48 & 50 kw installation layout FUEL TANK TOTAL CAPACITY 253.6 [67] USABLE CAPACITY 230.9 [61] CAPACITY: LITER [GALLONS] DIMENSIONS: MM [INCH] 353 [13.9] Drawing #0K6968A-A (2 of 2) Protector Series 11 of 6 757 [29.8] 621 [24.5] 267 [10.5] 181 [7.1] REMOVABLE COVER 112 [4.4] 1194 [47.0] 1044 [41.1] FUEL FILL FUEL LEVEL GAUGE/SENDER INNER TANK NORMAL VENT 923 [36.4] 828 [32.6] INNER TANK EMERGENCY VENT HIGH AND LOW VOLTAGE STUB-UP CIRCUIT BREAKER, NEUTRAL AND CUSTOMER CONNECTION OPENING 786 [30.9] STUB-UP AREA 125 [4.9] 51 [2.0] 1431 [56.3] 38 [1.5] 1554 [61.2] 112 [4.4] 1764 [69.4] 187 [7.3] STUB-UP AREA 712 [28.0] 1242 [48.9] 1842 [72.5] 1954 [76.9] 851 [33.5] 888 [35.0] FUEL RETURN FUEL SUPPLY REMOVABLE STUB-UP COVER 16.7 [.66] MOUNTING HOLES (8 PLACES)

Protector Series 15 20 30 48 50 kw available accessories Model # Product Description 006505-0 - 15 & 20 kw 006506-0 - 30, 48 & 50 kw Tank Risers Tank risers are required in some municipalities to help avoid potential base tank corrosion caused by mounting on rough surfaces. 12 of 6 006512-0 Lockable Fuel Cap The cast iron, lockable fuel cap provides the ability to lock the fuel system to prevent unwanted fuel tampering or fuel siphoning. 006572-0 - 15 & 20 kw 006571-0 - 30 kw 006570-0 - 48 & 50 kw 006560-0 - 15 & 20 kw 006559-0 - 30 kw 006558-0 - 48 & 50 kw Maintenance Kits Cold Weather Kits The Protector Maintenance Kits offer all the hardware necessary to perform complete maintenance on Ottomotores Protector generators. Recommended for generators installed in regions where the temperature regularly falls below 32 F (0 C). The Cold Weather Kits consist of a block heater with all necessary mounting hardware and a battery warmer with a thermostat built into the battery wrap. 005704-0 Paint Kit 006664-0 Local Wireless Remote If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. Completely wireless and battery powered, Generac's wireless remote monitor provides you with instant status information without ever leaving the house. 006665-0 Wireless Remote Extension Harness Recommended for use with the Wireless Remote on units up to 60 kw, required for use on units 70 kw or greater. 006873-0 Smart Management Module (50 Amps) Manage large loads by utilizing up to 8 individual Smart Management modules. These devices are installed directly in line with existing appliance wiring for easy installation. Generac Power Systems, Inc. S45 W29290 HWY. 59, Waukesha, WI 53189 generac.com 2015 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0K4730-H Printed in U.S.A. 07/21/15