Similar documents
.410 (10.41) 1/4-40 UNS-2A Ø.115 (Ø 2.92) .410 (10.41) Ø.115 (Ø 2.92) Ø.115 (Ø 2.92)

.570 (14.48).415 (10.54) Ø.115 (Ø 2.92) .410 (10.41) Ø.115 (Ø 2.92) Ø.115 (Ø 2.92)

SERIES 34A Miniature Toggle Switches

T he Cole Series S3900 miniature P.C. termination rotary switch

ROTARY SWITCHES. Quality Features: LIGHTED ROTARY UP TO 3 POSITIONS WITH 3 OPTIONAL, INDEPENDENT LED LIGHT POSITIONS, 1.45 X.

T he Cole Series P3900 miniature P.C. termination rotary switch

Series 47B: Sealed Miniature Rocker and Paddle Switches

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59.

Switches. SERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY 115VAC, 28VDC)

AP/UP, AP/MIL Series Magnetic Circuit Protectors

A Type Switch Assemblies. With Silver - Plated Brass Contacts and Solder Terminals

M Series Half-inch Rotary Switches

Cole s Series 3600 one inch diameter rotary switch is designed for

MS-Series. Circuit Breaker

MINIATURE SWITCHES. Sensitive Snap-Action Pushbutton Switches Solder and P.C. Terminals (Momentary Action)

Amphenol 67 and 165 Series Miniaturized Standard Connectors

Environment-Sealed Basic Switches

Snap Action Miniature Pushbutton Switches

PERFORMANCE SPECIFICATION SHEET SWITCHES, SENSITIVE, 10 AMPERES AND LOW LEVEL, UNSEALED

Features Metal shaft and bushing Consistent, smooth quality feel Up to 4 sections available Rotary switch option designed for on-off function control

1000 Series Miniature Slide Switches

9000 Series Power Rocker and Lever Handle Switches

Distinctive Characteristics

C&K 1000 Series Miniature Slide Switches

Optical and Mechanical. Encoders

Fuseholders PAGE. Fuseholders.

F-Series. Circuit Breaker

ANT. Materials. Features. Miniature Toggle

F-Series. Circuit Breaker

MINIATURE POSITIVE ACTION SWITCHES MIL-S-8834 Miniature Positive Action Switches Solder Lug Terminals

or 0.5Ω whichever is greater (152 only) Temperature Coefficient of Resistance MODEL 152 MODEL 159 Refer to standard

ST SERIES - MINIATURE TOGGLE SWITCHES

PERFORMANCE SPECIFICATION SHEET SWITCHES, SENSITIVE, PLUNGER, 10 AMPERES 2PDT AND 7 AMPERES 4PDT, RESILIENT SEAL

CIT SWITCHTM ANT SPECIFICATIONS

Series 308 Electrical Specifications

DETAIL SPECIFICATION SHEET SWITCHES, TOGGLE, MINIATURE, LEVER SEAL, PANEL SEAL, FOUR POLE LOGIC LOAD TO 5 AMPERES

Optical and Mechanical. Encoders

Type N connectors DIVIDER PAGE

THREADED & BAYONET CONNECTORS FOR DEMANDING ENVIRONMENTS

MINIATURE SWITCHES. Sensitive Snap-Action Pushbutton Switches Solder and P.C. Terminals (Momentary Action)

ches UL File No. E101598

13000 series Professional quick-break momentary pushbutton switches

Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US

1980 Rotating Cam Limit Switches. Ordering Guide & Technical Information

PERFORMANCE SPECIFICATION SHEET SWITCHES, SENSITIVE, SPDT, UNSEALED

PART NUMBER BREAKDOWN CP A 70 1 W D H - 10


mm Square Sealed Panel Control

CONTENTS HMK SERIES X.100 CONNECTORS

Series 300. Miniature Rocker & Paddle Switches

PB-Series. GFCI/ELCI & Panel Seal

M Series Pin and Socket Connectors Catalog Revised 3-01

Series 80 Mighty Mouse Technical Reference Complete Product Specification

Amphenol 97 Series MIL-DTL-5015

AP/UP, AP/MIL Series Magnetic Circuit Protectors

8500 Series Subminiature Pushbutton Switches

SP1-T100B1M1QE MINIATURE TOGGLE SWTH SPDT (RC)

ANR SPECIFICATIONS. MATERIALS RoHS COMPLIANT - E222871

DATA-CON-X : SEALED USB TYPE A & B CONNECTORS

table of contents Switches J 1 SECTION SECTION J Quick Guide to Switches... J2-J3

SERIES 100 SWITCHES TOGGLE SWITCHES - MINIATURE. Phone: Fax: SPECIFICATIONS MATERIALS

Kulka Military Class (A-A-59125)/(MIL-T-55164)

A Series 1-4 Pole Rotary Switches

FR circuit breaker - hydraulic magnetic,

mm Square Sealed Panel Control

Jay-El Mark 11 P/N 10648

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

RTA Series 1 4 Poles Coded Rotary Switches

Momentary or alternate action pushbutton switches. UL approved 3A 250VAC, 6A 125VAC. Availability : consult factory for details of approved models.

Amphenol 348 Series High Density Connectors

5000 SERIES - MINIATURE TOGGLE SWITCHES

ELECTRICAL SPECIFICATIONS

Series 70 Custom Potentiometer Designer Guide

4.7. Contents Description Heavy Duty Hesitation Switches. Product Description. Standards and Certifications. Heavy Duty Hesitation Switches

MARK 11 JAY-EL MARK 11 P/N ILLUMINATED PUSHBUTTON SWITCH MIL-S-22885/77 ON THE QUALIFIED PRODUCTS LIST

General Specifications

G-Series. Circuit Breaker.


300 & 400 SERIES - MINIATURE PUSHBUTTON SWITCHES

C&K 7000 Series Miniature Toggle Switches


SolidMatrix 1206 Fast Acting Surface Mount Fuses

C&K E Series Sealed Miniature Toggle Switches

Fuseholders Enclosed Fuseholders > Circuit Board Mounted. Shock-Safe Holder (Circuit Board Mounted) Product Characteristics.

Amphenol /Matrix MS/Standard MIL-C-5015 Cylindrical Connectors

onlinecomponents.com

7000 Series Miniature Toggle Switches

FR circuit breaker - hydraulic magnetic, railway, very high current. Datasheet

Ordering Information. Long Barrel Inductive Prox E2E2 2-WIRE AC. Rugged Inductive Prox Sensors Meet IP67 Requirements

T Series Subminiature Toggle Switches

7000 Series Miniature Rocker & Lever Handle Switches

Distinctive Characteristics

2.92mm connectors DIVIDER PAGE

2.4mm connectors 155

E Series Sealed Miniature Toggle Switches

8000 series Momentary or alternate action pushbutton switches

TABLE OF CONTENTS. Amphenol Aerospace is a Certified ISO 9001 Manufacturer.

Amphenol. Amphenol /Matrix MIL-C-83723, Series III Connectors. Bayonet, Threaded or Quick-Disconnect Coupling Connectors for Demanding Environments

How to Order CONTACT TYPE FLANGE TYPE MOUNTING CONTACT TERMINATION

Kulka Military Class (A-A-59125) / (MIL-T-55164*)

Transcription:

Multi-Deck SERIES,, and " Diameter, Amp, Standard, Military SR0 FEATURES Rugged Construction Insures Switch Operation for the Life of Your Equipment Many Circuitry Options MIL Qualified Versions MIL-S-/0 Features Choice Include: Shaft/ Panel Seal, Adjustable Stops, PC Termination, UL Recognized DIMENSIONS In inches (and millimeters) Standard, UL Recognized and Military Qualified Solder Lug Styles Rear Views Series.0 ±.0 (, ± 0,). ±.00 (, ± 0,) DIM. D ±.00 (0,) C OF NON-TURN L. TAB ±.0 (, ± 0,) DIM. C ±.0 (0,).0 ±.00 (, ± 0,) NON-TURN TAB. ±.00 (, ± 0,0) WIDE BY.0 ±.00 (0, ± 0,0) THICK. ±.00 (,0 ± 0,) OF SEE NOTE Note: Common location for a single pole per deck switch. For common location on multi-pole switches, see circuit diagrams.. ±.00 (,0 ± 0,).0 +.00.00 (, + 0,0 0,0) DIM. A +.0.00 (+ 0,0 0,) DIM. F ±.0 (0,) DIM. E ±.00 (0,) INTEGRAL ASSEMBLY NUT, DO NOT REMOVE DIM. B REF. STUD PROJECTION # THREAD.0 ±.00 (, ± 0,0) WIDE BY.0 ±.00 (0, ± 0,0) DEEP FROM A. (,) /- UNEF-A THREAD (MTG. HOLE = / MIN.) 0 0.0 (,) MIN. HOLE AFTER PLATING Series.0 ±.0 (, ± 0,) 0.0 (,) MIN. HOLE AFTER PLATING For rear view of, 0 and 0, see circuit diagram. No. Dimension B Approx. Weight No. Dimension B Approx. Weight of Dimension Style Style Grams of Dimension Style Style Grams Decks A A M or H Decks A A M or H.0 (,0).0 (,).00 (0,) 0.0. (,). (,).0 (,).0 0. (,).0 (,).00 (0,).. (,0). (,).0 (,).. (,).0 (,).00 (0,).0.0 (0,). (,).0 (,).0 0.0 (,0).0 (,).00 (0,). 0. (,). (,).0 (,)..0 (,).0 (,).00 (0,).0. (0,). (,).0 (,).0.00 (,). (,).0 (,)..0 (,0). (,).0 (,) 00. Grayhill part number and date code marked on detent cover label. Customer part number marked on request. Military part number marked when required. UL recognized markings as required. Dimension C D E F Series. (,).000 (,).0 (,0).0 (,) Series. (,). (,).000 (,). (,0) See pages F- through F-0 for specifications, accessories and ordering information. F- Grayhill, Inc. Hillgrove Avenue LaGrange, Illinois 0- USA Phone: 0--00 Fax: 0--0 www.grayhill.com

Multi-Deck CIRCUIT DIAGRAMS: Solder Lug Terminals Switch is Viewed From Shaft End and Shown in Position No. Note: All common terminals are located above base terminals as shown. Series & 0 Angle of Throw 0 OF C C 0 C C 0 C C ONE POLE TWO POLE THREE POLE THREE POLE Styles A, D and S Styles M, MS, H and HS C C 0 0 C C C C C C C FOUR POLE FIVE OR SIX POLE C C C 0 C Series & Angle of Throw C OF L C 0 C 0 C Series Angle of Throw ONE POLE TWO POLE OF C C C ONE POLE TWO POLE THREE OR FOUR POLE C C C C Rear Views Series 0 Angle of Throw OF C C C C C C 0 ONE POLE TWO POLE THREE POLE OF Series 0 Angle of Throw C C C ONE POLE TWO POLE 0 See pages F- through F-0 for specifications, accessories and ordering information. Grayhill, Inc. Hillgrove Avenue LaGrange, Illinois 0- USA Phone: 0--00 Fax: 0--0 www.grayhill.com F-

Multi-Deck SERIES " Diameter, Amp, PC Mount FEATURES Satisfies High Current Board Level Applications Angle of Throw Permits up to Ten Positions UL Recognized Versions DIMENSIONS In inches (and millimeters) Standard Style. ±.00 (, ± 0,) OF Grayhill part number and date code marked on detent cover label. Customer part number marked on request. UL recognized marking as required. CIRCUIT DIAGRAM: PC Mount Switch is Viewed From Shaft End and Shown in Position No. Note: All common terminals are located above base terminals as shown. Termination One-sided termination is standard for switches with to positions per pole. Two-sided termination is standard for switches with thru 0 positions per pole. thru 0 positions per pole and terminals from one side of switch are available on special order. See Special Options, page F-0 or contact Grayhill..000 ±.00 (, ± 0,) TERMINAL DIMENSIONS AT THIS POINT ARE.00 ±.00 (, ± 0,) WIDE BY.00 ±.00 (0, ± 0,0) THICK 0 ONE POLE.0 ±.00 (,0 ± 0,).0 +.00.00 (, + 0,0 0,0). ±.0 (, ± 0,) OF C. ±.00 (,0 ± 0,).00 ±.0 (, ± 0,).0 ±.00 (, ± 0,) DIM. A +.0.000 (+, 0,00). ±.00 (, ± 0,) PC BOARD MOUNTING PATTERN SHAFT END Shown for a two deck switch OF FRONT SUPPORT PLATE MOUNTING HOLES. (,).00 (,).0 (,0).0 (,). (,). (,0) DIM. B REF. STUD PROJECTION. ±.00 (, ± 0,) # THREAD.0 ±.00 (,0 ± 0,) COMMON LUG INTEGRAL ASSEMBLY NUT, DO NOT REMOVE.0 ±.00 (, ± 0,0) WIDE BY.0 ±.00 (0, ± 0,0) DEEP FROM A. (,) /- UNEF-A THREAD (MTG. HOLE=/ MIN.) OF BASE TERMINAL MOUNTING HOLES OF REAR SUPPORT PLATE MOUNTING HOLES C COMMON L TERMINAL MOUNTING HOLES.0 (,). (,) 0.0 ±.00 (, ± 0,). ±.00 (, ± 0,).00 ±.0 (, ± 0,).0 ±.0 (, ± 0,). ±.0 (, ± 0,). ±.00 (, ± 0,) SHAFT AND PANEL SEAL: Srs. & Standard Style The Series / Styles, which include the letter "S" with the exception of style "HS", are watertight sealed to the mounting panel by utilizing the panel seal kit. These switches are built with a front plate that does not have a non-turn tab. The panel seal kit consists of a grooved hex nut, a keyed washer and a keyed panel seal. The grooved hex nut is assembled to the switch bushing. The keyed washer is slid down the bushing slot and seated into the hex nut groove. The seal is likewise assembled to the bushing and hex nut. The keyed washer is required to provide seal integrity in the bushing slot. When assembled to the panel, the grooved nut, backing washer and seal require the same space as a normal mounting nut. Hence, the seal kit does not alter the dimensions. Panel seal kit includes a non-turn washer to be used into a blind hole in the back panel. For panel seal kit part dimensions, see Accessories. Style "HS" switches use a similar sealing method, except the integral assembly nut retains the panel seal. All sealed style switches are provided with a shaft to bushing internal seal. ADJUSTABLE STOP SWITCHES: Series and The standard and UL recognized switches are also available with adjustable stops. Two removable stop washers allow you to limit the number of switch positions as needed. A knurled nut is supplied to secure the washers if desired. These switches have no bushing keyway. All other dimensions, ratings and characteristics are the same as the standard fixed stop styles. Although not military qualified, the adjustable styles are useful in military equipment prototypes. However, when submitting the equipment for government approval, the fixed stop qualified style should be substituted. See additional adjustable stop switch information at the beginning of the Rotary Switch section. For ordering information, see page F-0. Front Views FIRST STOP Series Series 0 FIRST STOP Equivalent Styles For style A, use D For style A0, use D0 For style M, use D initially For style M0, use D0 initially For style U, use UD For style U0, use UD0 USE OF KNURLED NUT IS OPTIONAL ADJUSTABLE STOP WASHERS See page F- for specifications, accessories and ordering information. F- Grayhill, Inc. Hillgrove Avenue LaGrange, Illinois 0- USA Phone: 0--00 Fax: 0--0 www.grayhill.com

Multi-Deck SERIES SERIES " Diameter, Amp, Concentric Shafts FEATURES Two Switches in the Panel Space of a Single Shaft Rotary Military Qualified Versions MIL-/0 Choice of 0 Positions (Series ) or Positions (Series ) DIMENSIONS In inches (and millimeters) Standard Style and Military Qualified Rear Views.0 ±.00 (, ± 0,0). ±.00 (, ± 0,). (,) SER..000 (,) SER.. ±.0 (, ± 0,) C OF NON-TURN L TAB. (,) SER.. (,) SER. ±.0(0,).0 ±.00 (, ± 0,).0 ±.00 (, ± 0,) Note: Common location for a single pole per deck switch. For common location on multi-pole switches, see circuit diagrams. OF SEE NOTE NON-TURN TAB. ±.00 (, ± 0,0) WIDE BY.0 ±.00 (0, ± 0,0) THICK.. ±.00 ±.00 (, (, ± 0,). +.00.00 (, + 0,0 0,0).0 +.00.00 (, + 0,0 0,0) DIM. A +.0.00 (+0,0 0,) ± 0,).0 ±.00 (, ± 0,).0 ±.0 (, ± 0,) SER.. ±.0 (,0 ± 0,) SER. DIM. B REF. STUD PROJECTION # THREAD.0 (,0) SER..000 (,) SER. ±.00 (0,) SECTION SECTION A B CONTROLLED BY.0 (,). (,) SHAFT MILITARY NUMBER MARKED ON ALL QUALIFIED SWITCHES INTEGRAL ASSEMBLY NUT, DO NOT REMOVE.0 ±.00 (, ± 0,0) WIDE BY.0 ±.00 (0, ± 0,0) DEEP FROM A. (,) /- UNEF-A THREAD Series.0 ±.0 (, ± 0,) 0.0 (,) MIN. HOLE AFTER PLATING Series.0 ±.0 (, ± 0,) Number of Approx. Weight Decks Dimension A Dimension B Grams Section Section Style Style Style Series Series A B A, M or H A M or H. (,).0 (,).00 (0,) 0. (,).0 (,).00 (0,).0 (,).0 (,).0 (,) 0. (,).0 (,).00 (0,).0 (,).0 (,).0 (,) 0.0 (,). (,).0 (,).0 (,).0 (,).0 (,) 0.0 (,). (,).0 (,). (,). (,).0 (,) 0 0.0 (,) MIN. HOLE AFTER PLATING Grayhill part number and date code marked on detent cover label. Customer part number marked on request. Military part number marked when required. See page F- circuit diagrams, pole/deck, 0 and positions; poles/deck, positions. See page F- for specifications, accessories and ordering information. Grayhill, Inc. Hillgrove Avenue LaGrange, Illinois 0- USA Phone: 0--00 Fax: 0--0 www.grayhill.com F-

Multi-Deck SERIES and " Diameter, Amp, Add-A-Pot FEATURES Central Shaft Designed to Operate an Add-On Potentiometer Potentiometer Mounting Plates Provided Adjustable Stop Standard, Fixed Stop by Order Choice of 0 Positions (Series ) or Positions (Series ) DIMENSIONS In inches (and millimeters) Standard Style Series Rear Views.0 ±.00 (, ± 0,0). ±.00 (, ± 0,).000 ±.00 (, ± 0,). ±.0 (, ± 0,) Series FIRST STOP OF NON-TURN TAB. ±.0 (, ± 0,).0 ±.00 (, ± 0,).0 ±.00 (, ± 0,) SEE NOTE NON-TURN TAB. ±.00 (, ± 0,0) WIDE BY.0 ±.00 (0, ± 0,0) THICK. ±.00 (, ± 0,) 0.. ±.00 ±.00 (, (, ± 0,) ± 0,). +.00.00 (, + 0,0 0,0).0 +.00.00 (, + 0,0 0,0) DIM. A +.0.00 (+0,0 0,).0 ±.0 (, ± 0,) SER.. ±.0 (,0 ± 0,) SER..0 ±.00 (, ± 0,).0 ±.0 (, ±,) STOP WASHERS USE OF KNURLED NUT OPTIONAL /- UNEF-A THREAD Note: Common location for a single pole per deck switch. For common location on multi-pole switches, see circuit diagrams. Number of Dimension Approx. Weight Grams Decks A Series Series. ±.0 (, ±,) # THREAD.0 (,0) SER..000 (,) SER. ±.00 (0,) Series.0 ±.0 (, ± 0,) 0.0 (,) MIN. HOLE AFTER PLATING Series.0 ±.0 (, ± 0,) 0 STOP FIRST. (,) 0.0 (,). (,) 0. ±.0 (, ± 0,) 0 Two potentiometer mounting plates are supplied. Mounting plates have. (,) and.0 (,) diameter holes respectively for mounting potentiometers with /" and /" bushings. Additional nuts for the through bolts of the switch are provided for adjustment of mounting plate location. Tapered tongue on /" shaft provides coupling to screwdriver slots in potentiometer shafts. Plated brass spacers for ease of positioning mounting plate driving assembly are available on special request (sold only with switches). The use of spacers is recommended for other than prototype requirements. When ordering switches with spacers, give full details regarding special length, potentiometer being used, etc. See page F- circuit diagrams, pole/deck, 0 and positions; poles/deck, positions. Standard style, concentric shaft, add-a-pot switches have adjustable stops. See Adjustable Stop description. Fixed stop types are also available, see Standard Options page F-0. Grayhill part number and date code marked on detent cover label. Customer part number marked on request. Military part number marked when required. See page F- for specifications, accessories and ordering information. F- Grayhill, Inc. Hillgrove Avenue LaGrange, Illinois 0- USA Phone: 0--00 Fax: 0--0 www.grayhill.com

Multi-Deck SERIES " Diameter, Amp, Add-A-Pot FEATURES Military Qualified MIL-/0 Central Shaft Designed to Operate MIL Potentiometer Mounting Plate Options Provide Choice of Potentiometer Fixed Distance from Switch to Mounting Plate DIMENSIONS In inches (and millimeters) Military Qualified Style. ±.00 (, ± 0,). ±.00 (, ± 0,). ±.0 (, ± 0,). ±.0 (, ± 0,) OF NON-TURN TAB NON-TURN TAB. ±.00 (, ± 0,0) WIDE BY.0 ±.00 (0, ± 0,0) THICK Note: Common locations for a single pole per deck switch. For common location on multiple switches, see circuit diagram..0 ±.00 (, ± 0,).. ±.00 ±.00 (, (, ± 0,) ± 0,). +.00.00 (, + 0,0 0,0).0 +.00.00 (, + 0,0 0,0) DIM. A +.0.00 (+ 0,0 0,).0 ±.00 (, ± 0,). ±.0 (,0 ± 0,).0 ±.00 (0, ± 0,).0 ±.00 (, ± 0,). (,) REF..0 ±.0 (, ±,) # THREAD.000 ±.00 (, ± 0,) SEE POTENTIOMETER MOUNTING 0 OR CUSTOMER PART NUMBER MARKED ON SWITCH COVER UPON REQUEST. MILITARY NUMBER MARKED ON ALL QUALIFIED SWITCHES INTEGRAL ASSEMBLY NUT, DO NOT REMOVE /- NEF-A THREAD.0 ±.00 (, ± 0,0) WIDE BY.0 ±.00 (0, ± 0,0) DEEP FROM A. (,).0 ±.0 (, ± 0,) 0 Number Approximate of Dimension Weight Decks A Grams.0 (,0) 0.0 (,0). (,) Series M Add-A-Pot Switch is a concentric shaft unit with provision for potentiometer mounting. Outer shaft operates switch decks. Inner shaft terminates in tapered tongue, which allows any desired potentiometer to be mounted. The Series M Add-A-Pot is qualified to MIL-S-/-. Patent No.,,0. Grayhill part number and date code marked on detent cover label. Customer part number marked on request. Military part number marked when required.. ±.00 (, ± 0,0) R.. ± ±. (,) Potentiometer Mounting The two mounting plates shown below are supplied with each switch..0 ±.00 (, ± 0,0) () THROUGH BOLT HOLE ( EA.). ±.00 (, ± 0,0) (). ±.00 (, ± 0,0) R. Mounting Plate A Mounting Plate B See page F- circuit diagrams, pole/deck, positions..0 ±.00 (,0 ± 0,0) (). ±.00 (,0 ± 0,0) R. ±. (,) ±.0 ±.00 (, ± 0,0) (). ±.00 (, ± 0,0) R. See page F- for specifications, accessories and ordering information. Grayhill, Inc. Hillgrove Avenue LaGrange, Illinois 0- USA Phone: 0--00 Fax: 0--0 www.grayhill.com F-

Multi-Deck MILITARY QUALIFIED Single Shaft Switches The military styles of the single shaft Series and rotary switches are qualified to MIL-S- /, specifically SR0-. Qualification includes two temperature ranges. Unsealed styles M, MB, MG and MBG are qualified for - to C. Unsealed styles H, HB, HG and HBG, plus sealed styles HS, HBS, HGS and HBGS are qualified for - C to C. Qualification includes low level switching and shaft grounding as specified in MIL-S-. Qualification includes 0,,, 0 and 0 angles of throw with solder lug terminals. The military styles are dimensionally the same as the standard styles with two exceptions. The location of the common for the -pole switch differs (see circuit diagrams) and the non-turn tab for styles HS, HBS, HGS and HBGS differs per the Shaft and Panel Seal description following. Two Switches, Concentric Shafts The M style of the concentric shaft Series and switches is qualified to MIL-S-/, specifically SR0-. Unsealed switches are qualified for - C to C in 0,,, 0 and 0 throws. The standard and military styles of the concentric switches have the same dimensions with the exception of the location of the pole common (see circuit diagrams). The 0 and throws are described in the ordering information. If the, 0 and 0 throws are required, they can be provided in Section A of the Series ; see Standard Options, page F-. Add-A-Pot Switches The military style of the add-a-pot Series switch is qualified to MIL-S-, specifically SR0-. These unsealed switches are qualified for - C to C in 0,, 0 and 0 throws. The dimensions of the military style add-a-pot switches are not the same as the standard adda-pot switches; see drawings. All Qualified Switches Complete electrical ratings and characteristics for all of these qualified switches are listed on the following pages. Standard variations such as terminals, shaft and/or bushing length etc., which do not affect performance, can be marked as qualified product. Adjustable stops cannot be qualified. Contact Grayhill for details about variations. Military qualified switches may be ordered by the military M number listed in MIL-S-/ or by the Grayhill part number. They will be marked to specifications. MILITARY QUALIFIED SHAFT AND PANEL SEAL: Styles HS, HBS, HGS and HBGS The shaft is sealed to the bushing by an internal O-ring per MIL-P-B. The bushing is sealed to the panel with a silicone rubber washer and a stainless steel backing washer. The combined uncompressed thickness is 0.0" (,0). Since this switch has a flat cover, a non-turn washer is supplied (see Panel Seal Kit). If using it, mount it in front of the panel. For Panel Seal Kit, see pages F-0. SPECIFICATIONS: Electrical Ratings Standard Style Rated: To make and break the following loads: Angle of Throw 0 or or 0 0 Vac resistive amp amps amps - Vdc resistive amp amp amps Vac inductive 0. amp amps amps Vdc inductive 0.0 amp - Vdc inductive 0.0 amp Vdc resistive 0.0 amp To carry 0 amps continuously. Contact Resistance: 0 milliohms maximum Insulation Resistance:,000 megaohms minimum Voltage Breakdown:,000 Vac initially (00 Vac or better after most environmental tests) Life Expectancy: 00,000 mechanical cycles of operation. Note: Actual life is determined by a number of factors, including electrical loading, rate of rotation and environment, as well as maximum voltage breakdown required at the end of life. UL Recognition Styles UA, UD, UM, UP, US and USP Grayhill styles A and M and their variations (D, P, S and SP) of the Series,, and rotary switches have been tested by Underwriters Laboratories. The letter U in the style indicates proper marking as required by Underwriters Laboratories. These switches are recognized under file number E. The UL rating for the Series,, and is as follows: Electrical Parameters: style UA =.0 ampere at Vac. Style UM =.0 ampere at Vac and also. ampere at Vac, inductive load, 0. to 0. power factor. Rating based on the following criteria: Overload: 0 operations at 0% rated AC load Endurance: 000 operations at the rated load with 000 Vac dielectric strength before and after test Temperature Rise: Not to exceed 0 C when carrying rated AC load after test. Note: all dimensional drawings for the standard style Series,, and also apply to these switches, with the exception that switches are marked per specifications. Electrical Ratings Military Style General Rating: This rating is based on standard Grayhill tests of the Military style switch done at ambient conditions. It is provided for comparison to the Standard Style switch. Charts shown for non-shorting contacts (break CURRENT (AMPS) CURRENT (AMPS) VOLTAGE VAC RESISTIVE 0 0 0 0 CYCLES x,000... VOLTAGE 0 VDC RESISTIVE.0. INDUCTIVE.0 (. HENRIES).0 0 0 0 0 CYCLES x,000 before make) Voltage and Load: As listed in the chart One cycle is 0 rotation and a return through all switch positions to the starting position. The data for the curves was measured at sea level, C and % relative humidity. The Series,, and, style M, H and HS switches are made to meet requirements of MIL-S-, style SR0. Diallyl phthalate molded parts and the design of internal switching elements provide exceptional performance. Curves shown are typical load-life curves for Series,, and, style M, H and HS switches with 0 or angles of throw. They show the numbers of cycles of rotational life expectancy for the types of loads shown. Thus, with a amp, Vac resistive load, 0,000 cycles of life is expected. If the load is reduced to amps, life is increased to,000 cycles. The larger angles of throw (, 0 or 0 ) switch larger currents for a like number of cycles. Life limiting or failure criteria for these curves are: Contact Resistance: 0 milliohms maximum Insulation Resistance:,000 megaohms minimum between mutually insulated parts Voltage Breakdown:,000 Vac minimum between mutually insulated parts. These switches will carry 0 amps with maximum contact temperature rise of 0 C. Life can be predicted by Grayhill if less critical life characteristics, elevated temperature or reduced pressure is involved. F- Grayhill, Inc. Hillgrove Avenue LaGrange, Illinois 0- USA Phone: 0--00 Fax: 0--0 www.grayhill.com

Multi-Deck SPECIFICATIONS: MIL-S- Electrical Values Military Style Style M switches, at C, approximately % humidity and sea level pressure and style H and HS at C have been tested to make and break the following loads as stated in MIL-S-/SR0; 0 milliamperes at Vdc resistive, 00 milliamperes at Vdc inductive (. henries); milliamperes at Vac resistive. These switches have also been tested at reduced barometric pressure (0,000 feet), C at approximately % relative humidity to make and break the following loads as stated in MIL-S-/SR0; 00 milliamperes, Vdc resistive; milliamperes, Vdc inductive (. henries); 0 milliamperes, Vac resistive. When tested to these loads and conditions the style M, H and HS switches meet the following life limiting or failure criteria after,000 cycles in accordance with MIL- S-. Contact Resistance: 0 milliohms maximum Insulation Resistance:,000 megaohms minimum between terminals and shafts Dielectric Strength:,000 Vac (atmospheric pressure) and 0 Vac (reduced pressure) minimum between mutually insulated parts. When tested at sea level C and % relative humidity with failure criteria of 0 milliohms max. and 0 Vac breakdown voltage, these switches will make and break the following loads: 0 ma at Vdc, inductive (. henries);. amps at Vdc resistive;.0 amps at Vac, 0 Hz resistive, for 0,000 cycles. These switches also meet MIL-S-/SR0 for moisture resistance, medium and high shock, vibration (0 to 000 cps), thermal shock (- C to C), salt spray, explosion and terminal pull. Materials and Finishes Standard Style Bases: Melamine per (MIL-M-) ASTM-D- Cover, Deck Separators, End Plate and Rotor Mounting Plate: Phenolic per (MIL-M-) ASTM-D- Mounting Bushings, Lockwashers and Nuts: Brass, cadmium-plated per QQ-P-, Class, Type II Shaft, Cover Plate, Retaining Rings, Through Bolts, Shaft Extensions, Stop Arm, Thrust Washers Stop Washers and Rear Support Plate: Stainless Steel Detent Balls: Steel, nickel-plated Detent Springs: Tinned music wire Rotor Contact, Stator (Base) Contacts: Silver alloy Terminals (Except Common): Brass, leadtin plated and fused Common Plate, Including Solder Lug: Brass, silver-plated.000" minimum Mounting Hardware: Two mounting nuts.0" (,) thick by." (,) across flats and one internal tooth lockwasher are supplied with each switch. Materials and Finishes Military Qualified Bases: Diallyl per (MIL-M-) ASTM-D- Cover, Deck Separators, End Plate and Rotor Mounting Plate: Diallyl per (MIL-M-) ASTM- D- Mounting Bushings, Lockwasher and Nuts: Brass, cadmium-plated per QQ-P-, Class, Type II Shaft, Cover Plate, Retaining Rings, Through Bolts, Shaft Extensions, Stop Arm, Stop Washers, Thrust Washers and Rear Support Plate: Stainless steel Detent Balls: Steel, nickel-plated Detent Springs: Tinned music wire Rotor Contact: Silver alloy Terminals, Common Plate including Solder Lug: Brass, silver-plated.000" minimum Mounting Hardware: Two mounting nuts.0" thick by." across flats and one internal tooth lockwasher are supplied with each switch. Additional Characteristics Standard Style and Military Qualified Contact: Shorting or non-shorting wiping contacts with over 0 grams of contact force Rotational Torque: - ounce-inches depending upon the number of poles per deck, number of decks and angle of throw Mechanical Life Expectancy: 00,000 cycles of operation Shaft Flat Orientation: Flat opposite contacting position of pole number one (See circuit diagram). Stop Strength: For Standard style: poundinches minimum. For Adjustable stop styles: pound-inches Extended Stud: Single shaft switches of six or more decks and concentric shaft switches of a combination of five or more decks (Standard style) or four or more decks (Military style) have longer studs with extra mounting nuts for recommended double end mount. Grayhill, Inc. Hillgrove Avenue LaGrange, Illinois 0- USA Phone: 0--00 Fax: 0--0 www.grayhill.com F-

Multi-Deck CHOICES AND LIMITATIONS: Series,, and A = Standard, Solder Lugs P = Standard, PC Mount Terminals D = Standard, Adjustable Stops SINGLE SHAFT SWITCHES S = Shaft and Panel Seal U = UL Recognized M = Military Qualified C H = Military Qualified, C B = Military, Grounded Shaft G = Military, Low Level Rating Style Choices Angle of Number of Poles Positions Shorting or Series Unsealed Shaft/Panel Seal Throw Decks Per Deck Per Pole, Non-Shorting A S UA US UM M MS MB MBS MG MGS MBG MBGS H HS HB HBS HG HGS HBG HBGS D UD P UP Concentric Shaft Switches SP USP 0 thru 0 thru 0 N or S 0 thru 0 thru 0 N or S 0 thru 0 thru N or S 0 thru 0 thru 0 N or S 0 thru 0 0 thru 0 N or S 0 thru 0 0 or 0 N or S 0 thru 0 0 N or S 0 thru 0 0 N or S 0 thru 0 thru 0 N or S 0 thru 0 0 thru 0 N or S 0 thru 0 0 N 0 thru 0 0 N 0 thru 0 thru 0 N 0 thru 0 0 or 0 N 0 thru 0 0 N 0 thru 0 thru 0 N 0 thru 0 0 N 0 thru AJ ( thru ) N or S 0 thru AJ ( thru ) N or S 0 thru 0 AJ ( thru ) N or S 0 thru 0 AJ ( or ) N or S 0 thru AJ ( thru 0) N or S 0 thru AJ ( thru ) N or S 0 thru 0 thru 0 N or S Style Angle of Section A (Front) Section B (Rear) Series Choices Throw Decks Poles Position N or S Decks Poles Position N or S CONCENTRIC SHAFT, SWITCHES A UA M 0 0 0 0 0 0 thru 0 0 thru N or S 0 thru 0 0 thru 0 N or S 0 thru 0 0 thru N or S 0 or 0 0 thru 0 N or S 0 thru 0 0 thru 0 N or S 0 0 or 0 N or S 0 0 N or S 0 0 N or S 0 thru 0 0 thru 0 N or S 0 thru 0 0 thru 0 N or S 0 thru 0 0 thru 0 N or S ADD-A-POT SWITCHES D UD M 0 0 0 thru 0 AJ (-) N or S 0 thru 0 AJ (-) N or S 0 thru 0 AJ (-0) N or S 0 thru 0 0 thru N or S 0 thru 0 0 thru 0 N or S Second shaft operates a potentiometer supplied by the customer. Rear mounting plates are provided. For Adjustable Stop (with the letter D), use AJ instead of number of positions when ordering. For, 0 or 0 throws in Series switches of these styles, see Standard Options. For single pole switches with the maximum positions per pole, continuous rotation is possible. Specify fixed stop or continuous rotation when ordering single shaft switches. Concentric shaft switches have continuous rotation. Styles which include both M and S are not qualified but are made of the same materials and construction as qualified types. For qualified switches with shaft and panel seal, use equivalent HS style. UM switches are made of the same materials and construction as the M style switches. For military switch UM is not required; use M style. STANDARD OPTIONS Terminals, military qualified shielding, additional angles of throw, etc., see Options, page F-. ADDITIONAL FEATURES For single shaft switches with spring return, isolated positions, keylocks, see the Features Selection Chart, page F-. F- Grayhill, Inc. Hillgrove Avenue LaGrange, Illinois 0- USA Phone: 0--00 Fax: 0--0 www.grayhill.com

Multi-Deck ACCESSORIES Internal Tooth Lockwasher Figure A For a /" bushing. Approximately 0.00" (,) outside diameter,.0"(0,) thickness. Material is cadmium-plated steel. Part No. Q- For a /" bushing. Approximately 0.00" (0,) outside diameter,.0" (0,) thickness. Material is passivated stainless steel. Part No. J0 FIGURE A Non-Turn Washer Figure B Can be ordered as extra hardware for the Series 000,,,,,, B,, and rotary switches. The internal key of the washer slides into the bushing keyway. The right angle tab locks into a predrilled hole on the back side of the mounting panel. Material is brass, cadmium plates. Part No. C0- Panel Seal Kit Figure C Sold as a separate item to seal the switch bushing to the panel. The kit consists of four items: a grooved hex nut, a keyed washer, a keyed seal and a non-turn washer. Assembly is described on Page F-. Dimensions of panel seal kit items are shown in Figure C. This kit seals the bushing to the panel; it does not seal the shaft to the bushing. Not usable with adjustable stop switches. Part No. -. ±.00 (, ± 0,). +.00.000 (, + 0,0). ±.00 (, ± 0,). ±.00 (, ± 0,0).0 ±.00 (0, ± 0,0). ±.00 (, ± 0,).0 ±.00 (, ± 0,0).00 ±.00 (, ± 0,0). +.00.000 (, + 0,0 0,00).00 ±.00 (0, ± 0,0). ±.00 (, ± 0,). +.00.000 (, + 0,0 0,00). ±.00 (,0 ± 0,).0 ±.00 (, ± 0,0) FIGURE B.0 (,)/.0 (,) Non-Turn Washer Seal Keyed Washer Hex Nut FIGURE C.0 ±.00 (0, ± 0,0). ±.00 (, ± 0,). (,) ACROSS FLATS ORDERING INFORMATION: Single Shaft Switches, Add-A-Pot Switches M0 0 N F Series: Determined by the type of switch and the angle of throw Style*: Letter(s) from the Choices and Limitations chart Angle of Throw: Must agree with Series Number Control knobs available. See page E-. Number of Decks: As limited by the angle of throw, the poles per deck, switch style and type of contacts Stop Arrangement: Add letter F to a one pole per deck switch with the maximum number of positions for a stop between position and the last position. Leave blank for continuous rotation Type of Contacts: N = Non-shorting; S = Shorting Positions Per Pole: Requires 0 positions as a minimum to maximum allowable dependent on the angle of throw and poles per deck. Use AJ for adjustable stops (Styles D and UD). Poles Per Deck: As limited by angle of throw, switch series and style * All rotary switches that are required to have military designated markings and testing adhering to MIL- are to be ordered by specifying the military part number identified on the appropriate slash sheet. ORDERING INFORMATION: Concentric Shaft M00N M00S Series: Determined by the angle of throw, applicable to both sections Style*: Letter(s) from the Choices and Limitations chart Section A (front) Number of Decks: As limited by the number of poles per deck Poles Per Deck: As limited by the angle of throw Positions Per Pole: Requires 0 positions as a minimum to the maximum allowable dependent on the angle of throw and the poles per deck Type of Contacts: N=Non-shorting, S=Shorting. All one pole per deck switches with the maximum number of positions are continuous rotation Section B (rear) The limitations listed for Section A apply to Section B Type of Contacts Positions Per Pole Poles Per Deck Number of Decks Style Control knobs available. See page E-. * All rotary switches that are required to have military designated markings and testing adhering to MIL- are to be ordered by specifying the military part number identified on the appropriate slash sheet. Available from your local Grayhill Distributor For prices and discounts, contact a local Sales Office, an authorized local Distributor or Grayhill. Grayhill, Inc. Hillgrove Avenue LaGrange, Illinois 0- USA Phone: 0--00 Fax: 0--0 www.grayhill.com F-0