GE8-AA- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA 59 General partner Elektrobau Mulfingen GmbH Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRB 59 Nominal data Type Motor GE8-AA- ME-CA Phase ~ ~ Nominal voltage VAC Frequency Hz 6 Method of obtaining data fa fa Valid for approval/standard CE CE Speed (rpm) min - 6 6 Power consumption W Current draw A.9. Capacitor µf.5.5 Capacitor voltage VDB Capacitor standard S S Min. back pressure Pa Min. back pressure inho Min. ambient temperature C -5-5 Max. ambient temperature C 55 55 ml = Max. load me = Max. efficiency fa = Free air cs = Customer specification ce = Customer equipment Subject to change Item no. 55-5-998 ENU Change 86 Approved 6-6- Page / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () 798 8- Fax +9 () 798 8- info@de.ebmpapst.com www.ebmpapst.com
GE8-AA- Technical description Weight Fan size Rotor surface Impeller material Housing material Direction of rotation Degree of protection Insulation class Max. permitted ambient temp. for motor (transport/storage) Min. permitted ambient temp. for motor (transport/storage) Installation position Condensation drainage holes Mode Motor bearing Touch current according to IEC 699 (measuring circuit Fig., TN system) Electrical hookup Motor protection Protection class Motor capacitor according to EN 65- in safety protection class Conformity with standards. kg 8 mm Unpainted Sheet steel, galvanized Die-cast aluminum Clockwise, viewed toward rotor IP; installation- and position-dependent "B" + 8 C - C Any None S Ball bearing <.75 ma Via terminal strip, capacitor connected Thermal overload protector (TOP) internally connected I (with customer connection of protective earth) S EN 65-; CE Item no. 55-5-998 ENU Change 86 Approved 6-6- Page / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () 798 8- Fax +9 () 798 8- info@de.ebmpapst.com www.ebmpapst.com
GE8-AA- Product drawing Connection diagram L blue N black PE green/yellow Item no. 55-5-998 ENU Change 86 Approved 6-6- Page / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () 798 8- Fax +9 () 798 8- info@de.ebmpapst.com www.ebmpapst.com
GE8-AA- Curves: Air performance Hz Druck p f s[pa]für Rho=,kg/m^ qv[cfm] 6 7 8 9,9,85,8 Measurement: LU-67-9 8 7 6,75,7,65,6,55,5,5, pfs_e[in HO] Air performance measured according to ISO 58 installation category A. For detailed information on the measurement setup, contact ebm-papst. Intake sound level: Sound power level according to ISO 7 / sound pressure level measured at m distance from fan axis. The values given are valid under the specified measuring conditions and may vary due to conditions of installation. For deviations from the standard configuration, the parameters have to be checked on the installed unit. 9,5 8 7, 6,5,,5, 6 7 8 9 qv[m^/h] 6 7 8,5 9 Measured values U V f Hz n min - 6 98 5 P e W 8 7 5 I A.9.7.6.5 m /h 55 95 6 Pa 7 7 cfm 9 75 55 5 inho..8.5.68 U = Power supply f = Frequency n = Speed (rpm) P e = Power consumption I = Current draw = Air flow = Pressure increase Item no. 55-5-998 ENU Change 86 Approved 6-6- Page / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () 798 8- Fax +9 () 798 8- info@de.ebmpapst.com www.ebmpapst.com
GE8-AA- Curves: Air performance 6 Hz Druck p f s[pa]für Rho=,kg/m^ qv[cfm] 6 7 8 9,5 9 8 7 6 9 8 7 6 9 8 7 6 6 7 8 9 qv[m^/h] 6 7 8,,5,,5,95,9,85,8,75,7,65,6,55,5,5,,5,,5,,5,,5 9 pfs_e[in HO] Measurement: LU-67- Air performance measured according to ISO 58 installation category A. For detailed information on the measurement setup, contact ebm-papst. Intake sound level: Sound power level according to ISO 7 / sound pressure level measured at m distance from fan axis. The values given are valid under the specified measuring conditions and may vary due to conditions of installation. For deviations from the standard configuration, the parameters have to be checked on the installed unit. Measured values U V f Hz 6 6 6 6 n min - 6 85 67 9 P e W 7 I A..9.7.6 m /h 55 5 9 Pa 6 cfm 9 8 inho...8. U = Power supply f = Frequency n = Speed (rpm) P e = Power consumption I = Current draw = Air flow = Pressure increase Item no. 55-5-998 ENU Change 86 Approved 6-6- Page 5 / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () 798 8- Fax +9 () 798 8- info@de.ebmpapst.com www.ebmpapst.com