US Water ph Booster-Reducer Injection System

Similar documents
US Water ORP Booster Injection System

US Water Systems Magna Pre-Filter

Pulsar Fluoride Removal Filter

Owners Manual Models: 081-MXF-GS-XXX. US Water Systems Matrixx Greensand Plus Iron Filtration System. Visit us online at

US Water Systems Big Blue Installation Guide Singles, Doubles and Triples

Owner s Manual Nitrate Series Salt Based Filter System

Owner s Manual. Soda Ash ph Neutralizer System

Owner s Manual. Calcite ph Neutralizer

Owner s Manual. PS48/PS80 Advantage Series Salt Based Water Softeners

Installation, Operation and Maintenance Manual

MULTI-STAGE FILTRATION SYSTEM INSTALLATION INSTRUCTIONS

Owner s Manual Pelican Whole House Iron and Manganese Filtration System

Installation Manual DIAPHRAGM WELL TANK

HALLMARK INDUSTRIES INC

Dual Port Manifold Water Filtration Systems Instruction Manual

Medi-Flow. Model M101 & M101D Medicator Instructions GETTING TECHNICAL ASSISTANCE

Installation, Operation and Maintenance Manual

Air Curtain. Installation, Operating and Maintenance Instructions

INSTALLATION INSTRUCTION & OWNER S MANUAL

Operations and Parts Manual

Installation Instructions Soft Top Replacement Hardware, Wrangler

VSP SERIES Installation, Operation and Maintenance Manual

www. hydrofuse.com Installation Manual Fertilizer Machine V1.3

Installation Guide for O-SO PURE s Mineral Mizer

FIXED DEPTH INSERTION METER INSTRUCTIONS

Operating Instructions & Parts Manual. Supa-Lite Lever Grease Gun. Model 48UJ77

Chem-Feed Installation Instructions

Installation Instructions Receiver Rack (Part # 7700) Universal Application

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

Getz Equipment Innovators 450 lb Portable / Wheeled Unit Dry Chemical Fill System Part No: 3G0061/3G0063

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

Scale Feeder Manifold Water Filtration System Instruction Manual

MODEL G300 BRAKE BLEEDER

Value Super Filter Max Installation Manual

Installation Instructions **THIS RAIL MOUNTING KIT USES 11 BOLTS**

Penguin Gentoo 600B Cordless Sprayer User s Manual

Operating Instructions & Parts Manual. Truck Drain. Model 48UJ80 and 48UJ81

Owner s Manual GLASSLINED PUMP TANK

Full Flow Drinking Water System Model: 3MFF100

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Artesian2 Owners Manual

Dual/Triple Manifold Water Filtration Systems Instruction Manual

INSTALLATION AND OPERATION MANUAL

HM860 FLOWMETER OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD

StormPro BA Series Sump Pump

Cascade Owners Manual

A S S E M B L Y I N S T R U C T I O N S

2019-ON RAM 1500 INSTALLATION INSTRUCTIONS

4400 Airless Product Manual

Tiller Lock Assembly

SUNC3000 / Item #40885

Raydot LLC 24 Actuator (115 VOLT)

INSTALLATION & OPERATION MANUAL

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

RAM 1500, 2019 CLASSIC & 2010-ON 2500/3500 INSTALLATION INSTRUCTIONS

Presoak & Tire/Engine Cleaner Systems (Air Pump) DU TC_A & DU PS_A

MODEL 900 IMPELLER-TYPE FLOW METER

Installation and Operation Manual

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH

HSIV PLOW OPERATOR S MANUAL

Instruction Manual. Series R Peristaltic Pump. For file reference, please record the following data:

ROUSH FUEL SYSTEM UPGRADE CURRENT FORD MUSTANG 5.0L

PreSoak System (NonFoaming) DU PS1-HP DU PS6-HP

Water Jetter Units DU JT50 / DU JT100

Installation Instructions / Warranty

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

OWNER S MANUAL. 6. If you aren t competent to instal the pump, get help from a qualified source.

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

24 Linear Actuator 115 Volts A.C. (Cat. # C430A)

READ AND SAVE THESE INSTRUCTIONS. ComfortBreeze UV360-1 SYSTEM 24V Ultra-Violet Air Cleaner. Trion

(L 70 ) 3000K / 4000K / 5000K 12 50,000 50, K / 4000K / 5000K 15 50, K / 4000K / 5000K 18 50,000

High Pressure Pump Units featuring CAT PUMPS DUPM550 & DUPM570

UNIVERSAL CUSTOMIZABLE MUD FLAP INSTALLATION INSTRUCTIONS

Installation Instructions

MetroPrime 22MPC Self-Priming Centrifugal Pump

OWNER'S MANUAL. Royal Sovereign International Inc. RET Desk Series

Artesian Owners Manual

Universal Bevel Drives Service Manual

Model 2008 I Battery Operated Irrigation Timer with 3/4 in. Anti-Siphon Valve

Intended Use: Explanation of Signal Word Consequences

Installation & Service Manual

COVER PAGE CUSTOM QUICK INSTALL MOUNTING KIT NOTE!

Instruction Manual. Fudge Puppy Display Case

G500REC Manual Covering System for Containers

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

Laboratory Series. Ultraviolet Ozone Destruct System Installation, Operation and Maintenance Manual. One Source for All Your UV Needs!

Installation Instructions

4400 Airless Product Manual

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

Harvil 4 Foot Air Hockey Table

INSTALLATION INSTRUCTIONS

GETZ EQUIPMENT INNOVATORS PART NO.: 3G59419 MODEL: BV 101 P PNEUMATIC BELT VISE WITH EXTENDED BELT & ROLLER

RESPA -SD or Gideon HVAC Fresh Air Filtration System Installation Guidelines for John Deere 450J, 550J, 650J, 700J, 750J, 850J Crawlers

ESE Series Cast Iron Sewage Pumps

PPM EO-100 TM. Operation Manual

This Manual Provides Installation and Operation Instructions for the following models:

MASTER. Water Conditioning Corp. Installation and Operation Manual. MCA Combination Series Residential Units

GW-120 Bar Glass Washer

Transcription:

US Water ph Booster-Reducer Injection System 410-PHBOOST 410-PHREDUCER US Water Systems, Inc. 1209 Country Club Road Indianapolis, IN 46234 1-800-608-8792 info@uswatersystems.com www.uswatersystems.com REVISION 1.0, 11-3-14

Table of Contents Unpacking/Inspection... 2 Safety Guide..2 Proper Installation.3 Introduction 3 Water Meter Instructions.4 Chemical Solution Tank Injection Pump Mounting Instructions....6 Chemical Pump Wiring Instructions.....11 Chemical Injection Pump Start-up Instructions...12 Chemical Pump Adjustment Procedure...14 Routine Maintenance....15 Maintenance Schedule...15 Warranty.... 16 Unpacking / Inspection Be sure to check the entire system for any shipping damage or parts loss. Also note damage to the shipping cartons. Contact US Water Systems at 1-800-608-8792 to report any shipping damage within 24 hours of delivery. Claims made after 24 hours may not be honored. Small parts, needed to install the system, are in a parts bag. To avoid loss of the small parts, keep them in the parts bag until you are ready to use them. Safety Guide Check and comply with your provincial / state and local codes. You must follow these guidelines. Use care when handling the treatment system. Do not turn upside down, drop, drag or set on sharp protrusions. WARNING: This system is not intended for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Contact US Water Systems for disinfection treatment equipment. 2

Proper Installation This injections system must be properly installed and located in accordance with the Installation Instructions before it is used or the warranty will be void. Do not install or store where it will be exposed to temperatures below freezing or exposed to any type of weather. Water freezing in the system will break it. Do not attempt to treat water over 100 F. Do not install in direct sunlight. Excessive sun or heat may cause distortion or other damage to non-metallic parts. Properly ground to conform with all governing codes and ordinances. Use only lead-free solder and flux for all Introduction sweat-solder connections, as required by state and federal codes. WARNING: Discard all unused parts and packaging material after installation. Small parts remaining after the installation could be a choke hazard. The US Water ph Booster-Reducer system is a chemical injection system that proportionally injections a chemical mix to maintain a desired ph level in the water source. This system can raise or lower the ph depending on the chemical that is being injected in the water stream. A sample port (typically installed at a minimum of 18-24 down stream of the injection point or after a backwashing filter) and a ph meter are used to adjust the chemical pump rate to deliver the desired ph consistently. The pump rate will vary in each application. A fixed ph meter downstream of the injection system can be used to monitor the ph level as well. US Water ph Booster-Reducer System Proportional Injection to reduce chemical waste Adjustable pump rate setting to provide flexibility for feed water ph changes Quality Stenner Products utilizing a peristaltic pump. 3

Water Meter Installation Instructions 1. Install the water meter in plumbing. There is a flow direction arrow on the meter. Be sure the inlet plumbing is attached to the meter correctly. There should be 18 of horizontal pipe before and after the water meter to ensure it is reading properly. The connections are 3/4 male pipe thread. Contact US Water Systems for proper placement of the water meter in your water treatment system. 2. Slide the nut over the connection nipple, apply Teflon tape and install it in the inlet plumbing. Do not over tighten the plastic nipple or damage could occur. FLOW DIRECTION ARROW 3. Install the rubber washer gasket in the connecting nut and install the water meter with the flow arrow pointing away from the inlet fitting. Tighten the nut hand tight channel locks can be used to tighten the nut an additional 1/4 to 1/2 turn. The rubber washer gasket will seal the connection so the nut should not be over-tightened. 4

Water Meter Installation Instructions 4. Slide the nut over the outlet nipple and install the outlet nipple in the outlet plumbing. Use Teflon tape to seal the connection and tighten with channel locks. Do no over-tighten the nipple in the outlet plumbing connection or damage could occur. 5. Install the rubber washer gasket in the nut and tighten the outlet plumbing to the water meter outlet connection. Tighten it hand tight then turn it an additional 1/4 to 1/2 turn with channel locks. Do not over-tighten or damage could occur. 5

Chemical Solution Tank (with Pump) Installation Instructions 1. Install the chemical pump mounting bracket on the solution tank. Center the bracket on the back side of the tank. Install the two longer screws in the outer holes. Tighten all screws. 6

Chemical Solution Tank (with Pump) Installation Instructions 2. Install the chemical injection pump on the bracket that was installed on the tank using the screws taped to the bracket. 3. Drill a 1/4 hole in the top of the solution tank and install the tubing into the tank. 7

Chemical Solution Tank (with Pump) Installation Instructions 4. Install the weighted suction screen on the tubing that was inserted in the tank. Push the tubing down in the tank until the weighted suction screen is around 1 from the bottom of the tank. 5. Install the other end of the tank suction tube to the chemical injection pump inlet. The inlet is identified by an arrow point toward the pump. Be sure the sleeve is installed on the tubing properly. The beveled side of the sleeve should be facing the pump. Tight the nut hand tight holding the pump fitting. Do not use tools. Hand tightening will be sufficient. 8

Chemical Solution Tank (with Pump) Installation Instructions 6. Install a tee in the water pipe for the injection check valve. This should be at least 18 downstream from the water meter. The injection check valve has either 1/4 or 1/2 male pipe thread so the injection tee fitting installed should have a 1/4 or 1/2 female threaded port. The following pictures show an injection point after a backwashing filter. This tee may be installed before a backwashing filter in some cases. In certain applications, the injection point may just be in the water line at a differently location. Contact US Water Systems for proper placement of the injection check valve. Wrap the desired thread with Teflon tape and install in the tee fitting. Tighten hand tight then snug an additional 1/2 to full turn with channel locks or wrench. A sampling port or ph monitoring system should be installed after the injection system to aid in chemical pump adjustment. 9

Chemical Solution Tank (with Pump) Installation Instructions 7. Install a piece of tubing on the outlet of the pump. Be sure to orient the sleeve properly and hand tighten the nut. The outlet is identified by and arrow that is pointing away from the pump. 8. Install the other end of the chemical pump outlet tubing to the previously installed injection check valve. Be sure to orient the sleeve properly and hand tighten. 10

Chemical Pump Wiring Installation Instructions 1. The wire coming from the previously installed water meter should have three wires. A black, red and blue wire. The blue wire is not used and should be folded back and taped to prevent it from making contact with anything. 2. The wire coming from the chemical injection pump will have several colors. Fold back all wires except the red and black wire. Make sure the wires that are folded back are not touching each other or anything else. Tape the wires back. Now connect the black wires together with a wire nut or butt splice connector. Connect the two red wires using a wire nut or butt splice connector. There is no voltage on these wires. An enclosure can be used or the wires connections can simply be taped to insulate the wires if desired. 11

Chemical Injection Pump Start-up Instructions 1. Plug the chemical pump power cord into a continuously energized 110v outlet. The chemical pump should be set when the unit is shipped. It should be set to 5 SEC- ONDS and the percentage should be set on 50%. This setting will have to be adjusted. The factory setting is just a starting point. 2. If changes need to be made, the pump must be unlocked. If the pump is locked, push and hold the mode and the % percentage buttons at the same time and hold them for 3-5 seconds. The pump locked sentence will disappear. If STANDBY is on the screen. Push and hold the Mode and Stby buttons and STANDBY will disappear. 3. To change the mode to 5 SECONDS, hold the mode button while using the up or down arrows to change the setting. 4. To change the percentage, press and hold the % button while using the up or down arrows to change the percentage to the desired rate. 5. Once the pump is programmed pour the supplied ph adjustment chemical in the chemical tank. The chemical mixture procedure is as follows; ph Reducer Chemical (Ban T) 8 oz of Ban T per 5 Gallons of clean ph 7 neutral water Fill a 5 gallon bucket half full of water and pour in 8 oz of Ban T. Top of the 5 gallon bucket with water and mix well. Once mixed, pour the solution in the tank. This procedure is repeated to fill the tank. ph Booster Chemical (Neutra 7) 5 lbs of Neutra 7 per 6 gallons of water Fill a 5 gallon bucket half full of water then pour in 5 lbs of Neutra 7. Top of the 5 gallon bucket with water and mix well. Pour the solution in the tank. Add 1 additional gallon of water to the now empty 5 gallon bucket and mix and residual left in the bucket. Pour the 1 gallon of water in the chemical solution tank. Repeat this procedure to fill the tank. CAUTION! ph adjustment chemicals are corrosive! Proper protection should be worn when mixing or handling these chemicals. It is recommended that protective clothing, gloves and safety goggles be worn when handling the ph adjustment chemicals. Serious injury can occur from exposure to these chemicals. AL- WAYS MIX CHEMICAL IN WATER NEVER ADD WATER TO RAW CHEMICAL. KEEP OUT OF REACH! 12

Chemical Injection Pump Start-up Instructions 6. Now push and hold the prime button until the pump pulls the solution from the container up to the pump and on to the injector. The level can be seen in the tubing as the pump becomes primed. Once it is primed, the pump is ready to use. The pump will operate during the startup process. Proceed to the pump adjustment procedure. If the pump is not working see below. NOTE: If the pump is showing Standby, hold the MODE and push the STBY button to take the pump out of the standby mode. The display will not show Standby if it is normal operation. BE SURE to check that the pump is not in the Standby mode. If the pump is left in Standby, it will not operate during regeneration as intended. If the pump is Locked, it will need to be unlocked to make changes. If the valve is Locked, press and hold the MODE and % button at the same time for 3-5 seconds to unlock. The pump will only engage when water is being used. Water passing through the water meter is tracked by the meter and a pulse is sent from the water meter to the chemical injection pump. This pulse will engage the pump according to the water flow rate. This makes the adjustment process more precise and reduces chemical usage. 13

Chemical Pump Adjustment Procedure 1. Run the water system at the full flow. Pull a sample from the sample port and test the ph. The pump can adjusted UP or DOWN to reach the desired ph level. 2. To adjust the chemical pump rate, press and hold the % button while pushing the UP or DOWN arrows. 3. Repeat this process until the desired ph level is reached. There should be 5-15 minutes between testing and adjustments. In some cases the standard setting of 5 SECONDS, may need to be changed to achieved the desired ph level. The following selections can be used to adjust the pump rate; 1 SECONDS (Pump engages for 1 second at 100%) 5 SECONDS (Pump engages for 5 seconds at 100%) 10 SECONDS (Pump engages for 10 seconds at 100%) 20 SECONDS (Pump engages for 20 seconds at 100%) 60 SECONDS (Pump engages for 60 seconds at 100%) The pump uses a percentage value as the adjustment increment. EXAMPLE: A pump with a mode setting at 10 SECONDS with a percentage setting of 50% will engage for 5 seconds. The same pump set at 25% will engage for 2.5 seconds. If the system is overdosing the pump setting would be decreased. If the pump is underdosing, the pump rate should be increased. Typically the supplied pump will work in all applications. However, if there is a application that will not allow the proper dosing for an accurate ph adjustment, the internal pump tube can be replaced on the pump to adjust the overall output of the pump. The adjustment process can then be used at the new rates. Once the chemical pump rate is adjusted at full flow, the system will proportionally inject the chemical according to the usage flow rate. This will produce and accurate ph adjustment at any flow rate. 14

Routine Maintenance Injection Pump The internal pump tube and injection duck bill check valve may need to be replaced periodically. They typically last 1-5 years depending on the usage. There is a spare tube shipped with the system and instructional videos explaining how to change the tube at www.uswatersystems.com. Replacement duck bill check valves can be purchased at www.uswatersystems.com as well. Chemical Injection Check Valve The chemical injection check valve may need to be removed and cleaned periodically. In some cases, salt deposits can build on the chemical injection check valve inside the plumbing tee fitting. This check valve should be removed and cleaned. The injection tee should be checked for build up and cleaned as necessary. Component Action Frequency Injection Pump Tube Injection Pump Duck Bill Check Valve Chemical Solution Tank Inspect pump tube and replace as needed. Replace injection check valve as needed. Periodically check the solution level and refill as needed. 1-5 Years 1-5 Years Varies by water usage. 15

Warranty For the lifetime of the original purchaser, at the original residential place of installation of this Chemical Injection System, US WATER SYSTEMS, INC. warrants the following: ONE YEAR COVERAGE Valve Assembly & Electronics We warrant that for one (1) year from the date of purchase, we will replace the system assemblies or electronic components at no charge to you except for transportation and standard labor charges. Electronics or components damaged due to environmental issues or improper installation are not covered. GENERAL PROVISIONS This warranty does not apply to any commercial or industrial installations or to any part of the water conditioner which has been subjected to misuse, neglect, alteration or accident; or to any damage caused by fire, flood, freezing, Acts of God, or any other casualty, or if the original serial numbers have been removed. These warranties are in lieu of all other warranties expressed. or implied, and we do not authorize any person to assume for us any other obligation on the sale of this water conditioner. No responsibility is assumed for delays or failure to meet these warranties caused by strike, government regulations or other circumstances beyond the control of US WATER SYSTEMS, INC.. TO OBTAIN WARRANTY SERVICE, CALL OR WRITE: US WATER SYSTEMS, INC. 1209 COUNTRY CLUB ROAD INDIANAPOLIS, IN 46234 (800) 608-USWA. ANY IMPLIED WARRANTIES OF FITNESS OR MERCHANTABILITY ARE LIMITED TO THE TERMS OF THIS EXPRESSED WARRANTY AND THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THOSE HEREIN. US WATER SHALL NOT BE LIABLE FOR ANY INCIDENTIAL OR CONSEQUENTIAL DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATIONS OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE. THIS WARRANTY MAY BE TRANSFRRED TO A SUBSEQUENT OWNER WITH WRITTEN APPROVAL OF US WATER AND PAYMENT OF STANDARD TRANSFER FEE. 16