PVC Insulation with Nylon Jacket. Solid or Stranded Soft-annealed Uncoated Copper

Similar documents
THHN10STBRCP1250 THHN 10 STR Brown 1250 CP

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

MC, THHN/THWN-2 Copper


MTW/TEW UL STYLE MTW/TEW UL STYLES 1028/1283/ UL STYLES 1007/ UL STYLE SWITCHBOARD WIRE (SIS)...

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TC-RHH/RHW-2 USE-2 Copper

Southwire Company. Current Rating 70 AMPERE (60 DEG C), 85 AMPERE (75 DEG C), 95 AMPERE (90 DEG C) Ground Conductor Size

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable

IEEE 1580 TYPE T/N CABLE

UF103WG250 10/3 WG Uf Cable-250' Features. Material, Color, and Finish. Dimensions and Weight

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.

grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2

Omni Cable is a master distributor of specialty wire and cable selling

Section 8. Portable Cordage & Power Cable

PRODUCTS COMMERCIAL BUILDING WIRE & CABLE

EcoSystem Cable Low-Voltage Cables. Features Internal conductors match EcoSystem device terminal and lead color scheme.

MEDIUM VOLTAGE

Armorlite Type MC APPLICATIONS STANDARDS & REFERENCES CONSTRUCTION

MC122IG 12/2 WG MC Solid-Isolated Ground, Steel Armor. Features. Material, Color, and Finish. Dimensions and Weight.

WIRE & CABLE OVER A HALF CENTURY OF EXPERTISE

MC or MV-105 Copper, TR-XLPE Insulated

KALAS ENTERTAINMENT CABLE

STABILOY BRAND FeeDeR SOLuTIONS

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

Category # 1 - Overhead, Primary, & Secondary Conductors

STABILOY BRAND FEEDER SOLUTIONS INDUSTRIAL FACILITIES AND FACTORIES

ATHLETIC STADIUMS AND SPORTS ARENAS

PART A General Conductor Requirements

Primary, Secondary, Post-Secondary Education Facilities

HW250 REV 8/16 TYPE SOOW. 600 Volt UL/CSA, -40 C to 90 C Black Jacket Flexible Copper Conductors

Mecklenburg County Common Code Defects

NEC 2014 Code Changes

UNSHIELDED MULTI CONDUCTOR

DLO. Mining Cable. Mining Cable. 2 kv

Section 11 Mining Cable

High Voltage Copper, Smooth Aluminum Shield/Sheath

INDUSTRIAL

HOSPITAL AND HEALTHCARE

Agency Approvals UL and CSA China RoHS - Below MCV Yes Color Red EU RoHS Compliant Yes Maximum Recommended Voltage Rating 600 Volt Units per Box 100

Printer-friendly format 3M Scotchlok Electrical Spring Connectors Y- BOX 5-8#22, 4-6#20, 2-5#18, 2-3#16 AWG, 100 per box, Yellow. Learn More...

C-L-X Aluminum Sheath Type IEC

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable

CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications...

Marine Wire and Cable

CABLED TWISTED PAIRS CONDUCTORS

CABLED SINGLE CONDUCTORS

Hook-Up Wire Alpha Wire ALPHA 373

Type P Drilmar 125-XE Power/Distribution Cable Multiconductor

Delivering Dependability for More Than a Half Century

TUNNELING POWER CABLES

INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES

Technical Data Sheet Unshielded (YY) PVC Control Cable

LCT Shielded Primary UD EPR LCT Shielded Primary UD EPR Cable

Type P Drilmar 125-XE Signal & Instrumentation

Type MMV-WP Medium Voltage Wind Power Cable

Hook-Up Wire Cables you trust. Service you deserve.

Type P Drilmar 125-XE Signal & Instrumentation

LUTZE Flexible Cable and Wire Management for Industrial Automation. USA Cable Solutions

LCT Shielded Primary UD TRXLP LCT Shielded Primary UD TRXLP Cable

BRONCO PHILATRON. Brand. Premium Flexible Power Cable WIRE AND CABLE * USA MANUFACTURER

Airfield Ground Lighting

ULTROL Still ahead of its time after 30 years Class 1E nuclear rated cable

Single Core Cables 51

E R C. R E R C ; ; W T E C

Detailed Specifications & Technical Data

POWER. Lengths (ft) Nominal Overall Diameter. Part Number. Gauge /strands

USA: UL-listed (MTW), Canada: CSA (TEW), Europe: <HAR> H07V-K (depending on cross s.), tin-coated strands

Okoguard -Okoseal Type IEC

SUBMERSIBLE PUMP CABLES

DIVISION 16 - ELECTRICAL SECTION 16xx0 MANUFACTURED WIRING SYSTEM ACCESS FLOOR

ENGINEERED CABLE PRODUCTS

Technical Data Sheet Unshielded (YY) PVC Control Cable

ANSI/NEMA WC ICEA No. S Portable and Power Feeder Cables for Use in Mines and Similar Applications

Electrical Design/Build Guide

PRODUCT INFORMATION MULTI-STANDARD SC 2.1. U.I. Lapp GmbH

The Reliable Choice. Field Pocket Guide

SECTION. Watertight & Dust-Tight Plugs & Connectors

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

Wired for Power Generation

Battery Cables. Wire & Cable

N2XY IEC XLPE PVC 0.6/1kV Cable

NYY-J Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10

PHOTOVOLTAIC ARRAY WIRING HANDBOOK FOR STANDARD NOMINAL 6, 12, 24, AND 48 VOLT SYSTEMS. (for SX-60 series or smaller and MSX-120 solar modules)

SOOW 90 C. Portable Cord. Portable Cord 10.2 SOOW 90 C

Use the following standards for system design and performance requirements.

Medium Voltage Power Cables

600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC

EcoSystem Bus Cable. EcoSystemTM. Cable. Low Voltage Cables

Spring Test 10 due 05/11/2013

Variable Frequency Drive (VFD) Cable Solutions

Technical Data Sheet Shielded (CY) PVC Control Cable

Automotive Cables. The Global Cable Solutions Company

Industrial Cable SERVING INDUSTRIAL, SPECIALTY AND COMMERCIAL APPLICATIONS

ADVANCED CALCULATIONS

CABLE SOLUTIONS. to meet the application needs of nuclear power plants TODAY AND INTO THE FUTURE

Transcription:

THHN/THWN-2/MTW/T90 PVC Insulation with Nylon Jacket Solid or Stranded Soft-annealed Uncoated Copper Specifications ASTM (American Society for Testing & Material ASTM B3 Class B, B8 (sizes 6 and larger), B787 (#14, #12, #10 & #8) Underwriters Laboratories UL 83 Thermoplastic Insulated Wire and Cables UL 1063 Machine-Tool Wire (for 19, 37 and 61 strand product) UL 758 AWM Spec 1316, 1317, 1318, 1319, 1320, 1321 C (UL) C22.2 No. 75 for T90 Institute of Electrical and Electronics Engineers IEEE 1202 For CT rating 1/0 and larger National Electric Code NFPA 70, NFPA-79 (AWM 600V 105 C/75 C in oil) Federal Specification A-A59544 RoHS Compliant for Lead Free NEMA WC 70/ICEA S-95-658 Construction Conductors: Solid bare copper per ASTM B3 Stranded bare copper per ASTM B3, ASTM B787, ASTM B8 Insulation: Lead-free, color-coded compound that is heat-, flame-, and moisture-resistant Polyvinyl Chloride (PVC) per UL 83 and UL 1063 Jacket: Clear nylon (polyamide) or UL-listed equivalent jacket per UL 83 and UL 1063 Features: All sizes are rated for gasoline- and oil-resistant ll. All sizes are insulated with lead-free compounds and are RoHS compliant. 14 AWG thru 6 AWG conductors shall be listed Type THHN or THWN or THWN-2 or MTW or AWM and are suitable for operation at 600 volts at a conductor temperature not to exceed 105 C. 1/0 AWG and larger conductors shall be UL-listed Type THHN or THWN or THWN-2 or MTW and are rated for CT use and are suitable for operations at 600 volts in all installations as specified by the National Electric Code. 1/0 AWG and larger conductors are printed with Easy-Read sequential countdown marking which may assist in inventory controls. All conductors 1/0 AWG and larger are jacketed with SLK Technology nylon which could assist in pulling operations at the construction work site. Applications Type THHN/THWN-2 conductors are primarily used in conduit for services, feeder, and branch circuits in commercial or industrial applications as specified in the National Electrical Code. When used as Type THHN or TWN75, conductor is suitable for use in dry locations at temperatures not to exceed 90 C. When used as Type THWN or T90 Nylon, conductor is suitable for use in wet or dry locations at temperatures not to exceed 75 C or not to exceed 75 C when exposed to oil. When used as Type THWN-2, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C when exposed to oil. When used as type MTW, conductor is suitable for use in wet locations or when exposed to oil at temperatures not to exceed 60 C or dry locations at temperatures not to exceed 90 C (with ampacity limited to that for 75 C conductors per NFPA 79). Conductor temperatures not to exceed 105 C in dry locations when rated AWM and used as appliance wiring material. Voltage rating for all applications is 600 volts. Recommended Sample Specifications (MTW or THHN or THWN or THWN-2) Conductors shall be UL-listed Type MTW or THHN or THWN or THWN-2 gasoline- and oil-resistant II for CT use (1/0 and larger), suitable for operations at 600 volts in all installations as specified by the National Electric Code. Conductors shall be annealed copper, insulated with high-heat, moisture-resistant, and lead-free PVC, jacketed with abrasion-, moisture-, gasoline-, and oil-resistant nylon or UL-listed equivalent.

THHN/THWN-2/MTW/T90 Conductor Size (AWG or MCM/KCMIL) THHN/THWN- 2/MTW/T90 No. of Strands PCV Insula;on Thickness Nylon Jacket Thickness Nominal OD Approximate Net Weight per 1000 Z Allo3a5le Ampaci;es 60 C 70 C 90 C 14* 1 15 4 102 15 15 15 15 12* 1 15 4 119 23 20 20 20 10* 1 20 4 150 37 30 30 30 14* 19 15 4 109 16 15 15 15 12* 19 15 4 128 24 20 20 20 10* 19 20 4 161 38 30 30 30 8* 19 30 5 212 63 40 50 55 6* 19 30 5 250 95 55 65 75 4 19 40 6 319 153 70 85 95 3 19 40 6 346 189 85 100 110 2 19 40 6 378 234 95 115 130 1 19 50 7 435 300 110 130 150 1/0 19 50 7 474 372 125 150 170 2/0 19 50 7 518 463 145 175 195 3/0 19 50 7 568 576 165 200 225 4/0 19 50 7 624 719 195 230 260 250 37 60 8 694 849 215 255 290 300 37 60 8 747 1010 240 285 320 350 37 60 8 797 1175 260 310 350 400 37 60 8 842 1332 280 335 380 500 37 60 8 925 1652 320 380 430 600 61 70 9 1024 1990 355 420 475 750 61 70 9 1126 2468 400 475 535 * Suitable for 105 C wiring material (AWM) #14 - #1 are rated VW- 1 All AWG sizes are Rated THWN- 2 #8 and larger are rated Sun- Light Resistant (Black only) All AWG sizes are rated T90 1/0 AWG and larger are rated for Cable Tray Allowable AmpaciMes shown are for general use as specioed by the NaMonal Plectric CodeQR SecMon S10T15 60 C: When terminated to equipment for circuits rated 100 amperes or less or marked for AWG 14 thru 1 conductors MTW: Wet locamons or when eyposed to coolant 75 C: When terminated to equipment for circuits rated 100 amperes or marked for conductors larger than 1 AWG THWN when eyposed to oil or coolantt MTW dry LocaMons 90 C: THHN dry locamons

Circuits Purple Pink Grn/Yel Packaging Specifications THHN/THWN-2 14 and 12 AWG Put-up Ft/Pallet Spool/Reel Size 500' 108,000 6.5X4.5X1.875 2500' 120,000 11X10X4 500' spools packed 4 per carton 10 sld THHN Put-up Ft/Pallet Spool/Reel Size 500' 72,000 6.5X7X1.875 2500' 67,500 13X10X4 500' spools packed 2 per carton Smaller Intermediates Purple Grn/Yel Purple 8 str 6 str 500 24,000 10X9X4 500 13,500 12X11X8 1,000 27,000 12X9X4 1,000 18,000 15X13X8 2,500 25,000 16X13X6 2,500 30,000 23X12X10 5,000 40,000 23X12X10 5,000 20,000 23X16X10 20,000 20,000 36X22X14 15,000 15,000 42X22X16

Larger Intermediates 4 str 3 str 500 9,000 15X13X8 500 9,000 15X13X8 1,000 18,000 15X13X8 1,000 12,000 23X12X10 2,500 20,000 23X16X10 2,500 10,000 23X16X10 5,000 5,000 30X16X10 5,000 5,000 30X16X10 20,000 20,000 46X23X16 15,000 15,000 46X23X16 2 str 1 str 500 9,000 15X13X8 500 9,000 15X13X8 1,000 12,000 23X12X10 1,000 12,000 23X12X10 2,500 2,500 30X16X10 2,500 2,500 30X16X10 5,000 5,000 32X22X14 5,000 5,000 32X22X14 14,000 14,000 46X23X16 22,000 22,000 60X32X28 1/0 str 2/0 str 500 6,000 23X12X10 500 6,000 23X12X10 1,000 8,000 23X16X10 1,000 4,000 23X16X10 2,500 2,500 32X22X14 2,500 2,500 32X22X14 5,000 5,000 36X22X14 5,000 5,000 36X22X14 16,000 16,000 54X32X28 14,000 14,000 60X32X28 3/0 str 4/0 str 500 4,000 23X12X10 500 4,000 23X16X10 1,000 4,000 23X16X10 1,000 1,000 30X16X10 2,500 2,500 32X22X14 2,500 2,500 36X22X14 5,000 5,000 42X22X16 5,000 5,000 46X22X16 12,000 12,000 60X32X28 9,000 9,000 60X32X28

Feeders 250 MCM 300 MCM 500 2,000 23X16X10 500 2,000 23X16X10 1,000 1,000 30X16X10 1,000 1,000 30X16X10 2,500 2,500 42X22X16 2,500 2,500 42X23X16 4,000 4,000 46X22X16 4,000 4,000 46X23X16 8,500 8,500 60X32X28 7,000 7,000 60X32X28 350 MCM 400 MCM 500 500 30X16X10 500 500 30X16X10 1,000 1,000 32X22X14 1,000 1,000 32X22X14 2,000 2,000 42X23X16 2,500 2,500 42X23X16 2,500 2,500 42X23X16 3,000 3,000 46X23X16 3,000 3,000 46X23X16 5,000 5,000 54X32X28 3,500 3,500 46X23X16 16,000 16,000 54X32X28 500 MCM 600 MCM 500 500 30X16X10 500 500 30X16X10 1,000 1,000 32X22X14 1,000 1,000 32X22X14 1,500 1,500 36X22X14 2,000 2,000 46X23X16 2,000 2,000 42X23X16 2,500 2,500 54X32X28 2,500 2,500 46X23X16 3,000 3,000 60X32X28 3,000 3,000 48.5X23X17 4,000 4,000 60X32X28 750 MCM Put-up (ft) Ft/Pallet Spool/Reel Size 500 500 32X22X14 1,000 1,000 42X23X16 1,800 1,500 48.5X23X17 2,000 2,000 54X32X28